Thermo Scientific ExactFinder Software



Similar documents
Thermo Scientific SIEVE Software for Differential Expression Analysis

Getting Answers at the Source Requires a New Way of Thinking About Software

Thermo Scientific ClinQuan MD Software For In Vitro Diagnostic Use. Confidence in Results With Data Integrity

Thermo Scientific ConFlo IV Universal Interface

Thermo Scientific Prelude SPLC System FPO. Making LC/MS accessible. to clinical research and toxicology labs

Thermo Scientific PepFinder Software A New Paradigm for Peptide Mapping

TargetQuan 3 Software. Leading the way in regulatory. POPs quantification. Bullet Bullet Bullet

Thermo Scientific Compound Discoverer Software. A New Generation. of integrated solutions for small molecule structure ID

A Navigation through the Tracefinder Software Structure and Workflow Options. Frans Schoutsen Pesticide Symposium Prague 27 April 2015

Thermo Scientific icap 7000 Series ICP-OES. Low cost ICP-OES analysis high quality data

LC-MS/MS Solutions for the Pharmaceutical and CRO Industries TSQ Series -based Solutions for Drug Discovery and Development

Accurate Mass Screening Workflows for the Analysis of Novel Psychoactive Substances

Simultaneous Quantitation of 43 Drugs in Human Urine with a Dilute-and-Shoot LC-MS/MS Method

Application of Automated Data Collection to Surface-Enhanced Raman Scattering (SERS)

WATERS QUANTITATIVE ANALYSIS solutions

Unique Software Tools to Enable Quick Screening and Identification of Residues and Contaminants in Food Samples using Accurate Mass LC-MS/MS

Quick and Sensitive Analysis of Multiclass Veterinary Drug Residues in Meat, Plasma, and Milk on a Q Exactive Focus LC-MS System

LIFECYCLE. Thermo Scientific. Enterprise Solutions

Overview. Introduction. AB SCIEX MPX -2 High Throughput TripleTOF 4600 LC/MS/MS System

Thermo Scientific irm-gc/ms Technology

Thermo Scientific LIFECYCLE Asset & Service Management for Healthcare

MultiQuant Software 2.0 for Targeted Protein / Peptide Quantification

UHPLC/MS: An Efficient Tool for Determination of Illicit Drugs

A fully quantitative research method for the analysis of lead in whole blood using the Thermo Scientific icap Q ICP-MS

Pesticide Analysis by Mass Spectrometry

AxION edoor. Web-Based, Open-Access Mass Spectrometry Software

Selective Testosterone Analysis in Human Serum by LC-FAIMS-MS/MS

MultiQuant Software Version 3.0 for Accurate Quantification of Clinical Research and Forensic Samples

amazon SL Innovation with Integrity Setting New Standards in Performance, Simplicity and Value Ion Trap MS

AB SCIEX TOF/TOF 4800 PLUS SYSTEM. Cost effective flexibility for your core needs

Agilent 6000 Series LC/MS Solutions CONFIDENCE IN QUANTITATIVE AND QUALITATIVE ANALYSIS

Mass and Resolution Calibration for New Triple-Stage Quadrupole Mass Spectrometers. Rob Grothe Thermo Fisher Scientific, San Jose, CA

Bruker ToxScreener TM. Innovation with Integrity. A Comprehensive Screening Solution for Forensic Toxicology UHR-TOF MS

Thermo Scientific GENESYS 10S Series UV-Visible Spectrophotometers

MassHunter for Agilent GC/MS & GC/MS/MS

Pesticide residue analysis: New Trends. Michal Godula, Ph.D. EU Marketing Manager Food Safety & Environmental Thermo Fisher Scientific

HRMS in Clinical Research: from Targeted Quantification to Metabolomics

Thermo Scientific TSQ Quantum XLS Triple Quadrupole GC-MS/MS

Mass Frontier 7.0 Quick Start Guide

How To Control A Record System

Thermo Scientific Qtegra Intelligent Scientific Data Solution Software. Delivering quality. Driving productivity

Mass Frontier Version 7.0

Thermo Scientific Dionex Chromeleon 7 Chromatography Data System Software

Third Party Instrument Control with Chromeleon Chromatography Data System (CDS) Software

LC-MS/MS Method for the Determination of Docetaxel in Human Serum for Clinical Research

LC-MS/MS for Chromatographers

Metabolomic Profiling of Accurate Mass LC-MS/MS Data to Identify Unexpected Environmental Pollutants

Improving the Metabolite Identification Process with Efficiency and Speed: LightSight Software for Metabolite Identification

Introduction. What Can an Offline Desktop Processing Tool Provide for a Chemist?

Advantages of the LTQ Orbitrap for Protein Identification in Complex Digests

Utilization of Rapid LC-MS for Screening and Quantitative Analysis of Pesticides in Food Matrix using an Exactive Plus Benchtop Orbitrap Platform

INTEGRATED TECHNOLOGY TO SEE THE WHOLE PICTURE. AxION iqt GC/MS/MS

DRUG METABOLISM. Drug discovery & development solutions FOR DRUG METABOLISM

B i o s o l u t i o n s

[NUGENESIS SAMPLE MANAGEMENT ] AMPLE IMPROVING LAB EFFICIENCY, ANAGEMENT ACCELERATING BUSINESS DECISIONS. bigstock.com $69

Waters Core Chromatography Training (2 Days)

FT-NIR for Online Analysis in Polyol Production

Increasing Quality While Maintaining Efficiency in Drug Chemistry with DART-TOF MS Screening

Rapid Screening Method for Illicit Drugs, Using an Advanced Solid Core UHPLC Column and UHPLC System with MS/MS Detection

Using Natural Products Application Solution with UNIFI for the Identification of Chemical Ingredients of Green Tea Extract

Fast, Reproducible LC-MS/MS Analysis of Dextromethorphan and Dextrorphan

Application Note # LCMS-62 Walk-Up Ion Trap Mass Spectrometer System in a Multi-User Environment Using Compass OpenAccess Software

Daniel M. Mueller, Katharina M. Rentsch Institut für Klinische Chemie, Universitätsspital Zürich, CH-8091 Zürich, Schweiz

MarkerView Software for Metabolomic and Biomarker Profiling Analysis

API 3200 LC/MS/MS SYSTEM. Performance, productivity and value combined

[ Care and Use Manual ]

Thermo Scientific GC-MS Data Acquisition Instructions for Cerno Bioscience MassWorks Software

Enhancing GCMS analysis of trace compounds using a new dynamic baseline compensation algorithm to reduce background interference

Overview. Triple quadrupole (MS/MS) systems provide in comparison to single quadrupole (MS) systems: Introduction

Determination of Pesticide Residues in Drinking Water Using Automated Solid-Phase Extraction and Gas Chromatography with Nitrogen Phosphorus Detection

MRMPilot Software: Accelerating MRM Assay Development for Targeted Quantitative Proteomics

Image Lab Software for the GS-900 Densitometer

ProteinScape. Innovation with Integrity. Proteomics Data Analysis & Management. Mass Spectrometry

Volume 22 Number 22. C43-A ISBN ISSN Gas Chromatography/Mass Spectrometry (GC/MS) Confirmation of Drugs; Approved Guideline

Analysis of the Vitamin B Complex in Infant Formula Samples by LC-MS/MS

A Streamlined Workflow for Untargeted Metabolomics

AutoSpec Premier. Are you? Analyzing dioxins and related compounds? Required to satisfy regulatory requirements?

Bio-Rad Laboratories. QC data management solutions. Introduce Your Laboratory to a Whole New World of Unity Data Management Solutions

Simultaneous qualitative and quantitative analysis using the Agilent 6540 Accurate-Mass Q-TOF

Finnigan ELEMENT2. High Performance High Resolution ICP-MS

GENERAL UNKNOWN SCREENING FOR DRUGS IN BIOLOGICAL SAMPLES BY LC/MS Luc Humbert1, Michel Lhermitte 1, Frederic Grisel 2 1

# LCMS-35 esquire series. Application of LC/APCI Ion Trap Tandem Mass Spectrometry for the Multiresidue Analysis of Pesticides in Water

The Scheduled MRM Algorithm Enables Intelligent Use of Retention Time During Multiple Reaction Monitoring

Weight Loss Determined from Mass Spectrometry Trend Data in a Thermogravimetric/Mass Spectrometer System

Increasing the Multiplexing of High Resolution Targeted Peptide Quantification Assays

A High Throughput Automated Sample Preparation and Analysis Workflow for Comprehensive Forensic Toxicology Screening using LC/MS/MS

Technical Report. Automatic Identification and Semi-quantitative Analysis of Psychotropic Drugs in Serum Using GC/MS Forensic Toxicological Database

Chemical Profiling and Differential Analysis of Whiskies Using Orbitrap GC-MS

Agilent LCMS products and the application strategies in veterinary drug analysis

In-Depth Qualitative Analysis of Complex Proteomic Samples Using High Quality MS/MS at Fast Acquisition Rates

TotalChrom. Chromatography Data Systems. Streamlining your laboratory workflow

Simultaneous Qualitative and Quantitative Data Acquisition for Research of Diabetes Drugs

What is Eluent Generation?

SERVICE PLANS. More Productivity. Less Worry. SERVICE PLANS

Application Note # LCMS-81 Introducing New Proteomics Acquisiton Strategies with the compact Towards the Universal Proteomics Acquisition Method

How To Test For Contamination In Large Volume Water

ProSightPC 3.0 Quick Start Guide

[ EMPOWER 3 SOFTWARE ] MORE CAPABILITIES FOR YOUR LAB, MORE VALUE FOR YOUR ENTERPRISE

Cliquid ChemoView 3.0 Software Simple automated analysis, from sample to report

Transcription:

mass spectrometry Thermo Scientific ExactFinder Software Workflow software for routine targeted and general unknown screening Unifies qualitative and quantitative high-resolution accurate mass workflows in a single software package Ensures high confidence in screening results with multiple forms of verification Advanced algorithms increase throughput in Food Safety, Environmental Safety, and Forensic Toxicology laboratories Part of Thermo Fisher Scientific

Thermo Scientific ExactFinder Software Attain highest productivity and confidence in screening applications with remarkable ease. Laboratories performing routine targeted and general unknown screening in a range of applications, from food and environmental safety to forensic toxicology, face increasing pressure to improve productivity and simplify workflows, without compromising the quality of results. This pressure is driven by many trends, including increasing concern for contamination in our food and environment, as well as research in personalized medicine. As mass spectrometry becomes the preferred technology for routine targeted and general unknown screening of trace compounds, more demands are placed on lab technicians to embrace this technology and produce results. At a time when mass spectrometers are generating increasing amounts of high resolution accurate mass raw data, there is a clear need for simplified data processing and interpretation. The list of contaminants, drugs, and metabolites for which laboratories must screen and quantitate continues to grow. Laboratories are challenged to streamline time-consuming method development processes, and to respond promptly to new testing requirements. Confident identification and easy quantitation Thermo Scientific ExactFinder software used with any Orbitrap or Exactive series high-performance liquid chromatography/mass spectrometry system addresses these challenges. ExactFinder software offers a single streamlined data-processing, review and reporting workflow for both targeted and general unknown screening applications, in a single easy-to-use software package. With minimal manual intervention, ExactFinder software readily addresses applications where hundreds of compounds are screened, identified, confirmed, and ultimately quantified with a calibration curve. The software s simplified, intuitive workflows are for operators who process and review data, as well as experts who create processing methods and manage user access. 2 ExactFinder software can be used with any of the Thermo Scientific Orbitrap systems to take advantage of high-resolution, accurate mass (HR/AM) full-scan mass spectral data. ExactFinder software can process data collected using Thermo Scientific Xcalibur or LCQUAN software.

Qualitative and quantitative data processing in a single software package Until today, laboratories utilized multiple mass spectrometers and data processing packages in a qualitative and quantitative workflow. With ExactFinder software, qualitative and quantitative data processing are combined in a single, intuitive software package. QUAN QUAL Full Scan, All Ions Captured Area Ratio 0.60 0.50 0.40 0.30 0.20 R 2 = 0.9998 Target 0.10 0.00 0 20 40 60 80 100 120 Concentration (pg/ml) QUAL 100 QUAL QUAN 80 QUAN Area Ratio 0.60 0.50 0.40 0.30 0.20 R 2 = 0.9997 Target 0.10 60 Area Ratio 0.60 0.50 0.40 0.30 0.20 R 2 = 0.9996 Target 0.00 0 100 200 300 400 500 600 Concentration (pg/ml) 0.10 0.00 0 100 200 300 400 500 600 Concentration (pg/ml) 40 20 Screening Screening 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0 Superior high-resolution accurate mass capabilities The Thermo Scientific Orbitrap and Exactive series high-performance LC-MS systems have high-resolution, accurate mass (HR/AM) capabilities ideally suited for the qualitative and quantitative workflow. The systems Benefits of Orbitrap Technology: over three orders of magnitude for trace-level detection provide full-scan mass spectral data with mass resolution up to 100,000 FWHM, and mass accuracy within 2 ppm. The superior resolving power and mass accuracy enable accurate mass confirmation of compounds including isobaric species that differ only by a few milli-mass units. HR/AM data helps eliminate analytical false positives and false negatives due to interfering matrix components at masses close to the analytes of interest, increasing confidence in results. The systems also offer complete sample coverage and retrospective data analysis, making it possible to screen previously acquired data for new target compounds. retrospective data analysis switching, U-HPLC compatibility 3

Thermo Scientific ExactFinder Software Maximize laboratory throughput with unprecedented ease of use With simplified method setup and data review, plus automated data processing and reporting, ExactFinder software substantially increases laboratory productivity and offers unprecedented ease-of-integration into laboratory workflows. Easy setup of targeted and general unknown screening data-processing methods Whether you are screening or quantifying, method setup is surprisingly easy and fast. Methods are set up in three simple steps: select screening type, select or import the target compound database, and then choose the identification and confirmation settings. Compound databases provide targeted searching based on mass-to-charge, retention time and fragment ions. Compound databases are provided with the software, and usergenerated databases can be imported. When screening for unknowns, identifications can be made via HR/AM spectral library search, elemental composition and Internet search of chemical databases such as ChemSpider. For targeted screening methods with quantitation, parameters can be set for calibration, QC levels, and flagging criteria for data review. ExactFinder software allows users to cut and paste within the compound grid and automatically calculates molecular weights and mass-to-charge values to speed processing method setup. Because parameter-less peak detection (PPD) automatically and reliably finds peaks, definition of peak integration parameters is unnecessary. Fast, information-ri data review The ExactFinder software pr information-rich data review Flagging and color-coding op fast sorting of results. Review of general unknow results is sample-centric, pro access to the compounds de parameters that provided the the quality of the match. Clic to view integrated chromato corresponding mass spectra and to compare the expected isotopic pattern, to compare library spectra, or compare d spectra to actual spectra for 4 Regardless of your application, method development, laboratory productivity. Create your processing metho

ch ovides fast, capabilities. tions enable n screening viding fast tected, the match, and k on a sample grams and their information, and observed matching atabase verification. Review of targeted screening results is compound-centric, providing rapid access to the detailed results for each compound in each sample. Scroll through compound and sample lists, and then click on samples to view in one window the integrated chromatographic peaks, the calibration curve or the mass spectrum and its isotopic pattern. Parameter-less peak detection (PPD) automates peak detection and integration, yielding high quality data and calibration curves, and improved reproducibility. PPD eliminates manual errors, and increases the consistency and reproducibility of results. The integrated chromatographic peak is overlaid on the peak detected by PPD (shaded in pink). To match your workflow and processes, PPD can be used, or peaks can be manually integrated if desired. Simplified reporting To simplify and speed reporting, the ExactFinder software includes several preconfigured report templates. Report setup is fully integrated with method setup. Simply choose the report type, the results to include and the flagging options. Reports can be saved in several common formats including PDF, and can be exported in XML format. data review and reporting are simplified for maximum, review your data, and print your report. 5

Thermo Scientific ExactFinder Software Achieve highest confidence in screening results with multiple forms of compound identification and verification in one software package For unprecedented confidence in screening results, ExactFinder software integrates multiple forms of compound identification and verification, including its unique HR/AM spectral library and library search, isotopic pattern matching and ChemSpider database queries. made via HR/AM spectral library search, elemental composition, and Internet search of chemical databases such as ChemSpider one of the richest sources of structure-based compound information. High-confidence HR/AM library matching 6 For highest confidence in results, the ExactFinder software includes a novel LC/MS/MS HR/AM library of over 5000 mass spectra from over 1000 compounds including pesticides, veterinary pharmaceuticals, PPCPs, common drugs of abuse, and compounds of interest in forensic toxicology. All spectra were acquired with a Thermo Scientific LTQ Orbitrap Velos mass spectrometer under a range of mass spectrometer conditions similar to those used in routine targeted and general unknown screening experiments: in positive and negative ionization modes, in multiple dissociation modes (HCD and CID) and with multiple collision energies. Laboratories can add mass spectra applicable to their work into the ExactFinder library. To enhance confidence in library matches when analyzing complex samples, the ExactFinder software employs a reverse library search. In a reverse search, the experimental spectra are queried for a match with the ten most significant ions in clean library spectra. To help you evaluate match quality, scoring shows how many of the ions had hits and how close they are in mass to the experimental data.

State-of-the-art isotopic pattern matching The isotopic pattern matching algorithm with intelligent elemental composition calculation provides a dependable yet sophisticated means of compound verification and identification. In targeted screening experiments, the algorithm matches the expected isotopic pattern (based on the molecular formula) to that found in the experimental data. In general unknown screening experiments, it reliably suggests an elemental composition and provides a fit ranking. By comparing the expected isotopic pattern with the experimental data, the isotopic pattern matching algorithm strengthens confidence in screening results. Comparisons of the expected versus experimental isotopic patterns are easy to view when reviewing batches. Automated component detection Automated component detection provides rapid and effective peak detection. It detects very low-level components in complex sample matrices by substantially reducing data complexity. Automated component detection reviews raw data to determine which masses are due to chromatographic events and which are due to background. Background masses are then excluded from the processed file leaving only chromatographically significant information for further processing and review. The algorithm groups adducts, multiply charged ions and dimmers into one compound, further reducing the number of peaks to be identified. Raw data is retained, if needed, for later review. Relative Abundance Time (min) Automated component detection excludes background masses to provide superior peak detection and signal-to-noise. 7

Increase productivity in your laboratory and your application In addition to these offices, Thermo Fisher Scientific maintains a network of represen tative organizations throughout the world. Forensic Toxicology Forensic toxicology laboratories can use ExactFinder software to perform quantitation, targeted screening and general unknown screening. For laboratories performing pain management and drugs of abuse testing, the software substantially increases the productivity of targeted screening and quantitative analyses. The results can be automatically printed in real-time or viewed on the screen and then printed. The color coded flags make review extremely easy. Setting up data processing methods, interpreting results and running reports is simplified. The compound database and spectral library include approximately 1200 drugs of abuse for forensic toxicology screening. Environmental Testing For environmental testing laboratories, the ExactFinder software can significantly increase throughput in quantitative and qualitative workflows. Laboratories no longer need to perform extensive method development such as compound-dependent MRM parameter optimization. Routine targeted and unknown screening can be performed with minimal user intervention and training. Food Safety As new compounds are found in food, beverages, and drinking water, the demand for reliable, targeted and general unknown screening methods is increasing rapidly. The ExactFinder software offers multiple search capabilities enabling laboratories to confidently identify compounds in complex food matrices. care products (PPCPs) as per EPA method 1694 world-wide regulatory agencies and fungicides as melamine and acrylamide Africa-Other +27 11 570 1840 analyze.sa@thermo.com Australia +61 3 9757 4300 analyze.au@thermo.com Austria +43 1 333 50 34 0 analyze.at@thermo.com Belgium +32 53 73 42 41 analyze.be@thermo.com Canada +1 800 530 8447 analyze.ca@thermo.com China +86 10 8419 3588 analyze.cn@thermo.com Denmark +45 70 23 62 60 analyze.dk@thermo.com Europe-Other +43 1 333 50 34 0 analyze.emea@thermo.com Finland / Norway / Sweden +46 8 556 468 00 analyze.se@thermo.com France +33 1 60 92 48 00 analyze.fr@thermo.com Germany +49 6103 408 1014 analyze.de@thermo.com India +91 22 6742 9434 analyze.in@thermo.com Italy +39 02 950 591 analyze.it@thermo.com Japan +81 45 453 9100 analyze.jp@thermo.com Latin America +1 561 688 8700 analyze.la@thermo.com Middle East +43 1 333 50 34 0 analyze.emea@thermo.com Netherlands +31 76 579 55 55 analyze.nl@thermo.com New Zealand +64 9 980 6700 analyze.au@thermo.com Russia/CIS +43 1 333 50 34 0 analyze.emea@thermo.com South Africa +27 11 570 1840 analyze.sa@thermo.com Spain +34 914 845 965 analyze.es@thermo.com +41 61 716 77 00 analyze.ch@thermo.com UK +44 1442 233555 analyze.uk@thermo.com USA +1 800 532 4752 analyze.us@thermo.com www.thermoscientific.com Thermo Fisher Scientific, San Jose, CA USA is ISO Certified. 2011 Thermo Fisher Scientific Inc. All rights reserved. All trademarks are the property of Thermo Fisher Scientific Inc. and its subsidiaries. Specifications, terms and pricing are subject to change. Not all products are available in all countries. Please consult your local sales representative for details. BR63379_E 03/11S