How To Use A Powerplant With A Powerline 2.2 (Powerline 2) (Powerplant 2)



Similar documents
Kurz Instruments Inc. Document AV Document Title: MFTB Event Code Definitions. MFT B-Series Event Codes

PREMIUM CLEAN ROOM MONITOR MODELS 8630-CRM-S 8630-CRM-P

S4000TH HART. HART Communication Manual

SenseLink TM. End-Point Controller. Addendum

WA Manager Alarming System Management Software Windows 98, NT, XP, 2000 User Guide

Model EXAxt AV550G HART Protocol

MANUAL FOR MODEL MP30 ELECTRIC MOTOR DRIVEN LIMITED SERVICE CONTROLLER

Controller Automation, Model II+

AIR QUALITY SURVEILLANCE BRANCH ACCEPTANCE TEST PROCEDURE (ATP) FOR. Teledyne Advanced Pollution Instruments Model 400 E Ozone Analyzer AQSB ATP 002

SMS Alarm Messenger. Setup Software Guide. SMSPro_Setup. Revision [Version 2.2]

Variable Air Volume - VAV

4511 MODBUS RTU. Configuration Manual. HART transparent driver. No. 9107MCM100(1328)

Programmer/Controller

NX Series Inverters. HVAC Pocket Programming Guide

Using the STC firmware

OWNERS MANUAL. Status Monitor. for Windows 95, 98, ME, NT 4, 2000 & XP. SIGNALCRAFTERS TECH, INC.

DS1621 Digital Thermometer and Thermostat

PPM Users Manual Signature Software

INSTALLATION OPERATING & MAINTENANCE MANUAL

Micro Motion Net Oil Computer Software and NOC System

RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features:

INSIDE WDDCMON. User s Guide for the ENVIRO-TEC DDC Control System Windows Based Software

How To Use A Water Quality Monitor (Wqmsw)

REGTRONIC OPERATING INSTRUCTIONS

TURBOtech srl. SED-635 Digital Excitation System. Industrial Electronics Sector FEATURES

Systems BV MANUAL. Operator Panel (OP) INADCO Densimeter

Firmware version: 1.10 Issue: 7 AUTODIALER GD30.2. Instruction Manual

ROC Protocol Specifications Manual

RF Etch Monitor. Introduction

Input signal Maximum Range Accuracy. Thermocouple E -50 to 700 C (-58 to 1832 F) ±1 C

NOVA MULTI-MONITORING SOFTWARE. Instruction Manual

WEA-Base. User manual for load cell transmitters. UK WEA-Base User manual for load cell transmitters Version 3.2 UK

TAC I/NETTM MR-VAV-AX. Application Specific MicroRegulator TM

HVAC-32A. Operation Manual. Specifications. Digital Multistage Air Conditioning Controller with inbuilt Outside Air Economy function

Transmitter Interface Program

Procidia Control Solutions Dedicated Backup in a Single Variable Control Loop

Display Group Parameters

Temperature Transmitter TTX300

User Guide IM/AX4PH Rev. O. AX416, AX436, AX460, AX466 & AX468 Single and dual input analyzers for ph/redox (ORP)

RZAHUC program version 1.1 Regulation for Reznor Air Handling Units

Sierra S-Series Smart Interface Software User Manual

DS1621 Digital Thermometer and Thermostat

Master Programming Manual for TotalCare, CareSoft Elite, CareSoft Pro, Ion Pro and CareClear Pro Models

Interface Protocol v1.2

Configurator Software Manual

T-100-R Installation Guide

TC 1818a. Operating Guide. Control Module SWM-015.5

for CS flow / dew point sensors

BIODEX ADDENDUM BIODEX EMG/ANALOG SIGNAL ACCESS CONFIGURATION UTILITY SOFTWARE FOR SYSTEM 3 REVISION 2 AND SYSTEM 4 DYNAMOMETERS

Hydras 3 LT Quick Start

R&D Electronics 8440 N. Waukegan Rd., Morton Grove, IL (847) Issue 12/08/06 om_207f.doc --

7.6.4 Communication via BACnet MS/TP. Logical error. Maximum processing time, p2024[0] Process data monitoring time (setpoint timeout), p2040

Micro Motion Coriolis Interface Module User Manual (for ROC800-Series and FloBoss 107 Controllers)

Liebert Deluxe System/3

Rackmount Intelligent Pressure Scanners

INDUSTRIAL INSTRUMENTATION

Technical Datasheet Scalar Network Analyzer Model MHz to 40 GHz

Operational Overview and Controls Guide

GSM AUTO-DIALER With 10Amp Relay USER GUIDE

Olson Electronics Remote Power Monitoring Meter

RIGOL Data Sheet. DS1000E, DS1000D Series Digital Oscilloscopes DS1102E, DS1052E, DS1102D, DS1052D. Product Overview. Applications. Easy to Use Design

StarPac II Control Valves FCD VLAMN User Instructions. User Interface Manual

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

Pump Controller Type ABS PC 441 Monitoring and/or Control of Pumps and Pumping Stations

5100 Spreader Control Event Logging Installation, Calibration and Operation Manual

NTE2053 Integrated Circuit 8 Bit MPU Compatible A/D Converter

T775U Series 2000 Electronic Stand-Alone Controller

BACnet Protocol Implementation Conformance Statement

MODBUS for ECH 200 Serial Communication Protocol <IMG INFO>

Modbus Tutorial 7/30/01. Tutorial on TTDM-PLUS and TTSIM System Integration using Modbus

NL708 (XWA11V) Walk-In Temp / Door /Alarm / Light Module

NIC Controller & Web Interface

RS Stock No Instruction Manual RS-1340 Hot Wire Anemometer

InTouch Example Description

LOVELINK III- Process Monitoring, Logging, Graphing, & Configuration

Automation and Systems Technology. LABCONTROL TFM/TPM User Manual TroxMConnect Operating Software. 1. Introduction Software Installation 2

Software Manual RS232 Laser Merge Module. Document # SU Rev A

S300 Series Dust Monitors

EGCP-3 MC Revision H Software Revision F. Explanation of Software Changes Made for the EGCP-3 MC Control. Application Note 51298

FLOW CALCULATOR INSTRUCTION MANUAL MESURES BAMOPHOX M1 02 E MES FLOW CALCULATOR /1

Temperature & Humidity SMS Alert Controller

Sentinel I28 and Blackbelt Mass Flow Calibration and Verification

1. Central Monitoring System Software

Apéndice E Listado de constantes

Y-200 Multi-Stage Sequencer

Inwall Room Temperature Unit

KM Metering Inc. EKM Dash User Manual. EKM Metering Inc. (831)

F453. TiF453. User guide 10/11-01 PC

Instruction manual. ph Transmitter 2100 e

HEAT HEAT COOL HEAT PUMP COOL

WINDOW's Programming Software USER MANUAL

PDA Software Manual For the Windows CE and Mobile Operating Systems

Global Water Instrumentation, Inc.

Gigabyte Management Console User s Guide (For ASPEED AST 2400 Chipset)

Temperature & Humidity SMS Alert Controller

THEORY AND APPLICATION OF KURZ THERMAL CONVECTION MASS FLOW METERS INSTRUMENTS

Application Engineering

Transcription:

1.1 Program Mode Option # Menu Parameters 1 Basic Meter Setup (BASIC SETUP) 2 Flow Cutoff (FLOW CUTOFF) 3 Flow Correction Factor and Time Constant (FLOW CF/TC) 4 Setup Flow Totalizer Reset (RESET TOTAL) 5 Setup Analog Output #1 (AOUT 1) 6 Setup Analog Output #2 (AOUT 2) 7 Setup Run Mode Display (RUN DISPLAY) 8 Setup Relay Output Select Relay # [Display] Meter Type Is (IN-LINE FLOW/INSERTION FLOW) Tag Name [H] Flow Units [H] <Flow AreaWizard> [H] Duct Profile (ROUND/RECTANGLE) <ROUND> Inside Diameter <RECTANGLE> Duct Width Duct Height Flow Area (calculated from Duct Profile) [H] (can override with manual entry) Probe Depth (for INSERTION meter only) Analog Out 1 (FLOW RATE/VELOCITY/TEMPERATURE/PID) AO1at 4mA [H] AO1 at 20mA [H] Analog Out 2 (FLOW RATE/VELOCITY/TEMPERATURE/PID) AO2 at 4mA AO2 at 20mA Run Mode Display (SCROLLED/STATIC) <SCROLLED> Scrolled Vars (SCROLL ALL/FLOW ONLY/FLOW+TOT/FLOW+VEL/ TAG+FLOW/TAG+FLOW+VEL/FLOW+TOT+VEL/ FLOW+TEMP/FLOW+TEMP+VEL) Scroll Interval <STATIC> Static Vars (FLOW ONLY/FLOW+TOT/FLOW+VEL/TAG+FLOW/ FLOW+TEMP) Flow Cutoff SW (OFF/ON) Lo Flow Cutoff [Display] Sensor Blockage CF is (for INSERTION type only) Field Calib CF [H] Flow TC Sec [H] Totalizer Reset (MAN RESET/AUTO RESET) <MAN RESET> Reset Flow Total (YES/NO) [H] <AUTO RESET> Total Reset Cnt Reset Flow Total (YES/NO) [H] Analog Out 1 (FLOW RATE/VELOCITY/TEMPERATURE/PID) AO1at 4mA [H] AO1 at 20mA [H] Analog Out 2 (FLOW RATE/VELOCITY/TEMPERATURE/PID) AO2 at 4mA AO2 at 20mA Run Mode Display (SCROLLED/STATIC) <SCROLLED> Scrolled Vars (SCROLL ALL/FLOW ONLY/FLOW+TOT/FLOW+VEL/ TAG+FLOW/TAG+FLOW+VEL/FLOW+TOT+VEL/ FLOW+TEMP/FLOW+TEMP+VEL) Scroll Interval <STATIC> Static Vars (FLOW ONLY/FLOW+TOT/FLOW+VEL/TAG+FLOW/ FLOW+TEMP)

(ASSIGN DOUT) 9 Setup Alarm (ALARM SETUP) 10 Setup NE-43 Alarm (NE-43 ALRM) 11 Setup Pulse Output (PULSE OUT) 12 Setup Sensor Purge (PURGE TIMR) 13 Setup Flow Calibration Parameters (CALIB DATA) Assign Relay To (ALARM OUTPUT/TOT PULSE OUT/PURGE OUTPUT) <ALARM OUTPUT> See Setup Alarm <TOT PULSE OUT> See Setup Pulse Output <PURGE OUTPUT> See Setup Sensor Purge Select Alarm # Set Alarm x (OFF/ON) Alarm x Trigger (VELOCITY/FLOW RATE/TEMPERATURE/GLOBAL EVENT) Alarm x Trip (LOW SETPOINT/HI SETPOINT/LO AND HI SP) <LOW SETPOINT> LO Alarm Setpt <HI SETPOINT> HI Alarm Setpt <LO AND HI SP> LO Alarm Setpt HI Alarm Setpt Continue with Relay Setup (NO/YES) <YES> [Display] Alarm x Assigned to DO n Relay n State (NORMALLY OPN/NORMALLY CLS) NE-43 Alarm Type (LOW OUTPUT/HIGH OUTPUT) Pulse Output (OFF/ON) <ON> [Display] Pulse Output Assigned to DO m Flow Volume per Pulse Pulse Width Purge Timer (OFF/ON) [H] <ON> [Display] Purge Output Assigned to DO n Purge Time msec [H] Hold Time msec [H] Purge Intv min [H] [Display] Sensor SN Cal Flow Unit [Display] Factory STP Ref User Ref Temp [H] User Ref Press [H] Cal Curve Type (VELOCITY MAP/MULTIPLE CAL) <VELOCITY MAP> VM Reference (INTERNAL/EXTERNAL) Gas Mol Wt [Display] New Ref Density Gas Name # VM Data Sets (x) Flow Data for S1 # Data Pts At S1 (y) Raw Signal S1-1 Flow Data S1-1 : Raw Signal S1-y Flow Data S1-y : Flow Data for Sx # Data Pts at Sx (n) Raw Signal Sx-1 Flow Data Sx-1

14 Calibrate Outputs (CALIB AOUT) 15 Variable Flow Correction Data (VRMS DATA) 16 Remote Correction Factor Data (REMOTE CF) 17 Select Gas Calibration Curve (CAL CURVE) 18 Setup Data Logging (DATA LOG) 19 Setup Modbus Communication (MODBUS COM) 20 Setup External Input (EXT AINPUT) 21 Setup PID Data (PID SETUP) 22 Manual PID Adjust (PID CONTRL) 23 Setup Drift Check (DRIFT CHCK) : Raw Signal Sx-n Flow Data Sx-n Set 4.000 ma to Out 1 [H] Set 20.000 ma to Out 1 [H] [Display] AO1 Calib Coeff Set 4.000 ma to Out 2 Set 20.000 ma to Out 2 [Display] AO2 Calib Coeff Chk NE-43 Alarms (YES/NO) <YES> Low Alarm Check High Alarm Check Enter (ma) output [Display] (requested) ma and equivalent V Enter # of Flow Data Sets n [H] Enter Flow Data Set i to Change Ref Value Ri (Vrms-i) [H] Test Data Di (VdsAve-i) [H] Remote CF OFF/ON Enter # of Remote CF Data Points n Enter ExtInput.RemCF-D1 Enter ExtInput.RemCF-X1 : Enter ExtInput.RemCF-Dn Enter ExtInput.RemCF-Xn Curve Sel Mode (MANUAL SELECT/EXT INPUT LEV) <MANUAL SELECT> Cal Curve # Enable Data Log (OFF/ON) <ON> Log Interval Sec Dev Modbus Addr Modbus Mode (MODBUS RTU/MODBUS ASCII) Modbus Baud Rate (9600/14400/19200/38400/57600) Register Order(BYTE #12 34/BYTE #34 12) Ext Input Usage (CAL DATA SW/VM REFERENCE/PURGE COMMAND/ PID EXT. REF/REMOTE CF) <VM REFERENCE> Scale Unit Inp Val At 4mA Inp Val At 20mA Filter TC PID State (OFF/ON) PID Operation (MANUAL/AUTOMATIC) PID Control To (VELOCITY/FLOW RATE) PID Setpt Ref (INTERNAL/EXTERNAL) PID Setpoint Prop Gain (KP) Integral TC Derivative TC PID Low Limit PID High Limit Manual PID Adjust Auto Drift Check (OFF/ON) [H] Drift Chk Intrvl [H] % FS at Zero [H] Duration at Zero [H] % FS at Mid [H] Duration at Mid [H]

24 Change User Password (CHANGE PW) 25 Update FROM EEPROM (GET EEPROM) 26 Set Bootup Output Delay (BOOTUP DLY) 27-30 <Not Used> 31 Factory Meter Setup (METR CONFG) 32 Factory Sensor Setup (SENS CONFG) 33 Calibration Coefficients (INCAL CONF) % FS at Span [H] Duration at Span [H] Basic Setup Code Adv Setup Code Load From EEPROM (NO/YES) Bootup Out Delay Board Assy # Board Build Board Assy Rev. Probe Size # of Meters # of Outputs # of Alarms # of Pulse Out Purge Timer (DISABLED/ENABLED) PID Control (DISABLED/ENABLED) FD2 Sensor Limit (500 DEGC/600 DEGC) Rem Corr Factor (DISABLED/ENABLED) Multi Cal Curve (DISABLED/ENABLED) Reset Counters (YES/NO) Sensor S/N TC Mode (POWER MODE/CURRENT MODE) Sensor Type (FD=9/300/MD=9/100/CD=19/19/FD2=9/27) RP0 RT0 RX RY RB [Display] Sensor Material RP CSR RTC CSR Bar Code VPs ZERO VPs GAIN VPs TC VIph ZERO VIphGAIN VIph TC VRtcl ZERO VRtcl GAIN VRtcl TC VRtch ZERO VRtch GAIN VRtch TC VLS ZERO VLS GAIN VLS TC VL1 ZERO VL1 GAIN VL1 TC VExt ZERO VExt GAIN VExt TC VTemp ZERO VTemp GAIN VTemp TC VCal ZERO VCal GAIN VCal TC

34 Setup Manufacturing Data (PROD CONFG) 35 Save TO EEPROM (SAV 2 EEPR) 36 Bridge PID Coefficients (BRIDGE PID) 37 Disable AutoSave (AUTO SAVE) 38 Disable Terminal Home (CURSR HOME) 39 Extended Factory Setup (SETFACTORY) VDrv ZERO VDrv GAIN RP CSR Coeff RTC CSR Coeff Model Number Part Number(1) PAR#-F1-F2-F3-F4 Part Number(2) F4 thru F7 Part Number(3) F8 thru F12 Item Number Manufacture Date Last Cal. Date [Display] Sensor S/N Save to EEPROM (NO/YES) Bridge PID P Coeff Bridge PID I Coeff Bridge PID D Coeff AutoSave (DISABLED/ENABLED) Terminal Home (DISABLED/ENABLED) Manufacture Date Tag Name Probe Size Flow Units Flow Area Cal Flow Unit Factory Calib Temp Reference Factory Calib Press Reference Analog Out 1 (FLOW RATE/VELOCITY/TEMPERATURE/PID) AO1at 4mA AO1 at 20mA Analog Out 2 (FLOW RATE/VELOCITY/TEMPERATURE/PID) AO2 at 4mA AO2 at 20mA Run Mode Display (SCROLLED/STATIC) <SCROLLED> Scrolled Vars (SCROLL ALL/FLOW ONLY/FLOW+TOT/FLOW+VEL/ TAG+FLOW/TAG+FLOW+VEL/FLOW+TOT+VEL/ FLOW+TEMP/FLOW+TEMP+VEL) Scroll Interval <STATIC> Static Vars (FLOW ONLY/FLOW+TOT/FLOW+VEL/TAG+FLOW/ FLOW+TEMP) Dev Modbus Addr Modbus Mode (MODBUS RTU/MODBUS ASCII) Modbus Baud Rate (9600/14400/19200/38400/57600) Register Order(BYTE #12 34/BYTE #34 12) Reset Counters (YES/NO) VM Reference Gas Molecular Weight [Display] New Reference Density Gas Name Number of Calibration Curves Enter Calibration Flow Data (for each curve) (Factory Sensor Setup) Sensor S/N TC Mode (POWER MODE/CURRENT MODE) Sensor Type (FD=9/300/MD=9/100/CD=19/19/FD2=9/27) RP0

40 Set Analog Output Cal Coefficient (AO CALCOEF) RT0 RX RY RB [Display] Sensor Material RP CSR RTC CSR AO1 Slope Coeff AO1 Offset Coeff AO2 Slope Coeff AO2 Offset Coeff

1.2 Display Mode Option # Function Description 1 Basic Meter Setup (BASIC SETUP) 2 Flow Cutoff (FLOW CUTOFF) 3 Flow Correction Factor and Time Constant (FLOW CF/TC) 4 Setup Flow Totalizer Reset (RESET TOTAL) 5 Setup Analog Output #1 (AOUT 1) 6 Setup Analog Output #2 (AOUT 2) 7 Setup Run Mode Display (RUN DISPLAY) 8 Setup Relay Output (ASSIGN DOUT) 9 Setup Alarm (ALARM SETUP) 10 Setup NE-43 Alarm (NE-43 ALRM) 11 Setup Pulse Output (PULSE OUT) 12 Setup Sensor Purge (PURGE TIMR) 13 Setup Flow Calibration Parameters (CALIB DATA) 14 Calibrate Outputs (CALIB AOUT) 15 Variable Flow Correction Data (VRMS DATA) 16 Remote Correction Factor Data (REMOTE CF) 17 Select Gas Calibration Curve (CAL CURVE) 18 Setup Data Logging (DATA LOG) 19 Setup Modbus Communication (MODBUS COM) 20 Setup External Input (EXT AINPUT) 21 Setup PID Data (PID SETUP) 22 Manual PID Adjust (PID CONTRL) 23 Setup Drift Check (DRIFT CHCK) 24 Change User Password (CHANGE PW) 25 Update FROM EEPROM (GET EEPROM) 26 Set Bootup Output Delay (BOOTUP DLY) 27 <not used> 28 <not used> 29 <not used> 30 <not used> 31 Factory Meter Setup (METR CONFG) 32 Factory Sensor Setup (SENS CONFG) 33 Calibration Coefficients (INCAL CONF) 34 Setup Manufacturing Data (PROD CONFG) 35 Save TO EEPROM (SAV 2 EEPR) 36 Bridge PID Coefficients (BRIDGE PID) 37 AutoSave status (AUTO SAVE) 38 Terminal Home status (CURSR HOME) 39 Extended Factory Meter Setup (SETFACTORY) 40 Set Analog Output Cal Coefficient (AO CALCOEF) 41 Input Current (EXT INP ma) 42 Flow Data (FLOW DATA) 43 Temperature Data (TEMP DATA) 44 Input Voltage (INPUT VOLT) [H] 45 Sensor Output (SENSOR OUT) [H] 46 Sensor Control (SENSOR CTL) 47 Electronics Temperature (ELEC TEMP) 48 Sensor Leakage (SENS LEAKG) 49 Meter Event Code (EVENT CODE) 50 Firmware Version (FW VERSION)

1.3 Log Mode Option # Function Description 1 Event Log (EVENT) 2 Min/Max Data (MIN/MAX) 3 Trend Log (TREND) 4 System Configuration (CONFIG) 5 Snapshot of Flow Meter Data (RUN DATA)

1.4 Extended Utility Mode Option # Function Description 1 Drift Check at Zero (ZERO DRIFT) [H] 2 Drift Check at Mid-span (MIDSP DRIFT) [H] 3 Drift Check at Full-span (FULLSP DRFT) [H] 4 Drift Check Cycle (all tests) (CYCLE DRIFT) [H] 5 Reset Flow Total (RESET TOTAL) [H] 6 Reset Event Log Memory (DEL EVENTS) 7 Reset Min/Max Records (DEL MIN/MAX) 8 Reset Runtime Counter (RESET RUNTM) 9 RP Circuit Test (RP CIRCUIT) 10 RTC Circuit Test (RTC CIRC) 11 Input Cal Low Test (IN CAL LO) 12 Input Cal High Test (IN CAL HI) 13 End Input Cal Test (END IN CAL) 14 VLeak Cal High (VLEAK HI) 15 VLeak Cal Low (VLEAK LO) 16 Voltage Drive Test (VOLTG DRV) 17 Voltage Ramp Test (VOLTG RAMP) 18 Bridge PID Coefficents (BRIDGE PID) 19 Event Code Bit Test (EVENT TEST) 20 Display Input Voltages (INPUT VOLT) 21 Display Sensor Output (SENSOR OUT) 22 Display Sensor Control (SENSOR CTL) 23 Display Electrical Temperature (ELEC TEMP) 24 Sensor Leakage (SENS LEAKG)