Software Manual RS232 Laser Merge Module. Document # SU Rev A
|
|
|
- Gillian Wade
- 9 years ago
- Views:
Transcription
1 Laser Merge Module Document # SU Rev A The information presented in this document is proprietary to Spectral Applied Research Inc. and cannot be used for any purpose other than that for which it is intended. 10 rth Rivermede Road Concord, Ontario, CANADA L4K 2H2
2 Laser Merge Module Document # SU Rev A Table of Contents 1. INTRODUCTION CONTROLS Shutters Neutral Density Filters Power Monitor Microcontroller Interfaces RS-232 Interface RS232 PROTOCOLS Control Commands Command: Shutter Control Command: Shutter Status Command: Change Transmission Command: Read Transmission Command: Get Laser Line Setup Command: Read Power Monitor Commands Exposure Configure In Configure Out Configure Read In Configuration Read Out Configuration Read Exposure Configuration Other Commands Home Motor TRIGGER IMPLEMENTATION GUIDE Auxiliary connector Programmable TTL In Out Flow Charts Programming List of Figures Figure 1: In, Cycle driven flow charts Figure 2: In, State driven flowcharts Figure 3: Out flowchart The information presented in this document is proprietary to Spectral Applied Research Inc. and cannot be used for any purpose other than that for which it is intended. i
3 1. INTRODUCTION This manual is a compilation of material on the programming of the Laser Merge Module, model LMM5 using the RS-232C interfaces, and the triggering capability available via TTL and dedicated BNC connectors on the control unit. The document is presented in major segments starting with a description of the pertinent controls. 2. CONTROLS The LMM5 can be controlled either manually or by a computer via a RS-232 or TTL interfaces. The following is a compilation of the programmable controls and a brief description of their function. All references to controls and indicators are highlighted in bold in the descriptions below. The following figures show the front and rear panels of the control unit. 2.1 Shutters Mechanical shutters are built into the LMM5. A shutter is installed for each laser at the exit from the laser compartment. A master shutter is also installed prior to the exit from the head unit. The laser shutters are controlled by lighted momentary pushbutton switches located on the front panel of the control unit or by the computer. The pushbuttons are identified by the label Laser Select and by the laser position number (1-5). The light is red when the shutter is open. light is showing when the shutter is closed. Pushing the pushbutton will toggle the status of the shutter. The master shutter is initialised open about 5 seconds after power is applied by the Master Key switch and its indicator turns red. Any other shutter can now be selected as required. The Master Shutter pushbutton controls the master shutter in the same manner as the other shutters. If the Remote Interlock is open circuited, then all the shutters close immediately. 2.2 Neutral Density Filters Neutral density filter wheels are installed for each laser in order to provide intensity control. The manual controls for these mechanisms are located on the control unit. The controls consist of a three-position momentary toggle switch labelled Intensity Adjust to select increasing or decreasing intensity direction, or off. The toggle switch is held to continue the motion in the selected direction. It will stop when either the minimum or maximum point has been reached. A particular filter wheel is selected by opening the associated shutter. If more than one shutter is open, the filter wheel associated with the last one opened may be driven. A green indicator is provided for each filter wheel so that the operator can readily confirm which wheel is selected. The indicators are identified by the label Intensity Select and by the laser position number (1-5). When a filter wheel is selected and the momentary toggle switch pushed for increasing or decreasing intensity, the speed of the wheel starts off slow but increases if the switch is held in place. The wheel takes about 10 seconds to change from maximum to minimum or vice versa. 1
4 2.3 Power Monitor The LMM5 contains a built-in power monitor on the front panel of the head unit. An input connector is provided to accept the fiber cable connected to the LMM5 output. A BNC connector is provided to allow measurement of the DC voltage produced by the LMM5 output. The power monitor consists of a photodiode with neutral density filter and a resistive load. Thus, the current produced by the photodiode is converted to a voltage. This can be measured by a voltmeter attached to the power monitor output connector or via an analog-to-digital converter by the computer. 2.4 Microcontroller Interfaces Two BNC connectors are provided on the rear panel of the control unit. Both are used to coordinate the LMM5 with other experimental apparatus. The In is used to control the on/off cycle for laser illumination based on externally generated conditions. A set of exposure states is defined and the trigger steps through these states in order. The Out can be set in two modes, clock driven or state driven. For state driven, a TTL pulse will be sent every time the exposure state is changed. For clock driven, a TTL pulse is sent out at a regularly interval. 2.5 RS-232 Interface A 9-pin D subminiature connector (female), labelled Serial, is provided on the rear panel of the control unit to allow serial communication with the microcontoller. The arrangement is a standard DTE to DCE configuration and requires a straight cable to connect the control unit to a computer. The pin-out of this connector is as follows: pin 2--Rx from DTE; pin 3 Tx to DTE; pin 5 ground. 3. RS232 PROTOCOLS 3.1 Control Commands For further information contact David Cooper at [email protected] or x405 Command structure: The command structures listed in this document use binary values to issue the commands. However many serial communication programs prefer to send ASCII data. Therefore to send one binary byte the control software should always send the equivalent hexadecimal value in ASCII representation. This requires sending two bytes for every single byte of binary data. Any command sent to the controller should terminate with a carriage return (ASCII value 13). For example, to send the binary sequence 0x1A,0xFF,0x00,Ox12 the serial program should send the ascii string 1AFF0012<CR> or in ASCII values: 49,65,70,70,48,48,49,50,13 Serial settings are 19,200 bps, no flow control, one stop bit, no parity, 8 data bits 2
5 3.1.1 Command: Shutter Control Set the open/closed states of the shutters Op Code: 0x01 Data: 1 byte representing bit field for states of up to 8 shutters, 1 indicates shutter open and 0 means shutter closed. Return: One Ack byte is sent as 0x01 and indicates that the command was processed and 0xFF if there is any error Send: 0x01 0x02 opens shutter 2 and closes all others Receive: 0x01 operation is acknowledged Send: 0x01 0x09 opens shutter 4 and 1 and closes all others Receive: 0x01 tes: Shutters take 1-2 milliseconds to open so this command does not wait to see if shutters are set successfully before acknowledging. Use the shutter status command to verify shutter states Command: Shutter Status Read the open/closed states of the shutters Op Code: 0x02 Data: ne Return: 2 bytes. First byte is an Ack byte, 0x02. Second byte gives shutter states in a bit field as in shutter control. Send: 0x02 Receive: 0x02 0x02 shutter 2 is open, all others are closed Send: 0x02 Receive: 0x02 0x09 shutter 1 and 4 are open, all others closed tes: This command returns the status of the photodetector sensor on each shutter. It takes 1 2 milliseconds for this sensor to respond to a shutter operation Command: Change Transmission Set the Transmission of a specific laser line. This may be done through a filter wheel or an AOTF. Op Code: 0x04 3
6 Data: 3 bytes. First specifies the lines to change attenuation (line 1 is 0x00). Second and third give transmission from 0 to 1000 (0 is minimum transmission and 1000 is maximum). Byte order is big endian (high byte first). Return: 1 byte Ack 0x04 normally and 0xFF if there is an error. An error could occur if the device loses its position for the filter wheel or fails to set the voltage to an AOTF. When controlling a filter wheel, this command may take several seconds to acknowledge as it waits until the wheel movement is complete before acknowledging. Send: 0x04 0x03 0x02 0xBC sets the transmission to 700 (70.0%) on line 4. 0x02 is high byte (equals 512) and 0xBC is low byte (equals 188 so =700). Receive: 0x04 Ack tes: Transmission is logarithmic for a filter wheel. For our 20dB wheels 50% = 10dB and is actually 10% transmission. When the device with filter wheels is first turned on, the filter wheels automatically rotate to find the home sensor and then return to their position at initial power up. The AOTF (if applicable) is set to minimum transmission at startup Command: Read Transmission Read the current transmission setting for a specific laser line. This may be done for a filter wheel or an AOTF. Op Code: 0x05 Data: 1 byte to indicate which line to return Return: 3 bytes. First is an ack 0x05 for normal operation and 0xFF for error. Next two bytes give transmission from 0 to 1000 in big endian format as in change transmission command. Send: 0x05 0x03 read transmission of line 4 Receive: 0x05 0x02 0xBC transmission is Command: Get Laser Line Setup Read which laser line wavelength is installed in which slot. Op Code: 0x08 Data: ne Return: 17 bytes. First is an Ack 0x08 for normal operation and 0xFF for error. Each two bytes after gives the wavelength of the laser in the corresponding line for a total of 8 lines. The byte order is big endian (high byte first). The wavelength is in angstroms so 4610 corresponds to nm. A value of zero indicates that no laser line is assigned to that slot. Send: 0x08 4
7 Receive: 0x08 0x15 0xEA 0x13 0x2E 0x11 0x30 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 line 1 is 561 nm, line 2 is 491 nm, line 3 is 440 nm and lines 4-8 are not available Command: Read Power Monitor Read the voltage on the power monitor photodiode Op Code: 0x0A tes: not currently available with rs232 control. Future versions will have this capability. 3.2 Commands These commands define the function of the trigger in and out BNCs from the control box. Contact Spectral Applied Research for more information on trigger controls Exposure Configure Op-Code: 0x21 (33) Bytes Sent: 1+3M (1<=M<=20) Bytes: 1: # of exposure states (value of 1 to M) 2 to (M+1): exposure states (M+2) to (3M+1): exposure time Description: This command defines the exposure parameters that the unit cycles through upon receiving a trigger in. The number of exposure states determines the number of different shutter states that the unit will go through before repeating the cycle. The exposure states give the shutter states for each exposure in the cycle. The format is the same as the shutter control command so each bit in the byte indicates the state of the corresponding shutter. The exposure time gives a series of unsigned 2-byte integers that define the exposure time of each state. The exposure time is in 0.1 msec increments for a maximum of a bit more than 6.5 seconds. The behaviour of the exposure time depends on the trigger in mode (see below). In Step mode, the exposure time defines how long the shutter stays open before reverting to an all closed state. In Cycle mode, the exposure determines how long to wait before moving to the next state. 0x21;0x02;0x17;0x06;0x10;0x00;0x03;0xAD: Defines two exposure states- shutter 1 and 5 open then shutter 2 and 3 open with exposure times of sec and sec respectively In Configure Op-Code: 0x22 (34) Bytes Sent: 3 5
8 Bytes: 1: Enable(1)/Disable(0) In 2: # of trigger input before action 3: Define step(0) or cycle(1) trigger Description: This command enables or disables the trigger in input and defines the trigger behaviour. Send 0 in the first byte to disable the trigger in and 1 to enable it. Step trigger is defined by a 0 in the third byte and Cycle mode by a 1. See trigger documentation for behaviour of each mode. The number of trigger inputs before action determines the number of trigger inputs to receive before taking action such as starting a state sequence or moving to the next state. 0x22;0x01;0x02;0x00: Enables a Step trigger and requires two trigger in events for each step. tes: In is positive edge TTL. There is a jitter of up to 50 microseconds in processing the trigger in. Motor control function and shutter control (manual and usb) are disabled while trigger is active. Motor control is deactivated due to limited timing resources and speed of the MCU and shutter control is deactivated since shutter states are determined by the exposure configuration Out Configure Op-Code: 0x23 (35) Bytes Sent: 4 Bytes: 1: Enable(1)/Disable(0) Out 2: State(0)/Clock(1) driven mode 3-4: Exposure Time Description: This commands enables the hardware trigger out. The trigger out can either be state driven so a trigger out occurs every time the shutter changes exposure state, or clock driven with the period between trigger outs is determined by exposure time. For state driven, the exposure time determines the delay from the state change to the trigger out. The exposure time is in 0.1 msec increments with a maximum of a bit more than 6.5 sec. The trigger out is a TTL pulse with a width of a few microseconds. 0x23;0x01;0x00;0x03;0xAD: Define a state driven trigger out with a delay of sec 0x23;0x01;0x01;0x00;0xC8: Define a clock driven trigger out at 50 Hz (20 msec delay) tes: Motor movement is disabled when trigger out is active 6
9 3.2.4 Read In Configuration Op-Code: 0x25 (37) Bytes Sent: ne Return: Returns the state of the trigger in setup in the same format as the trigger in configuration command Send 0x25 Receive 0x25;0x01;0x02;0x Read Out Configuration Op-Code: 0x26 (38) Bytes Sent: ne Return: Returns the state of the trigger out setup in the same format as the trigger out configuration command Send 0x26 Receive 0x26;0x01;0x00;0x03;0xAD: Read Exposure Configuration Op-Code: 0x27 (39) Bytes Sent: ne Return: Returns the exposure parameters in the same format as the exposure configuration command Send: 0x27 Receive: 0x27;0x02;0x17;0x06;0x10;0x00;0x03;0xAD 3.3 Other Commands Home Motor Op-Code: 0x11 Bytes Sent: 1 Bytes Received: 2 Description: This command homes the specified motor and returns the number of steps to reach home. Repeating this command gives the number of steps for a complete revolution. tes: This command is only intended to be used for unit calibration and shouldn t be used by the end-user. 7
10 4. TRIGGER IMPLEMENTATION GUIDE There are two types of TTL triggers available for the LMM5 controller. The 15 pin auxiliary connector provides TTL control of the laser shutters and adjustments of the laser intensity. There are two BNC connectors that provide programmable functionality. One BNC is an output and the other is an input. The behaviour of these TTL connections can be programmed to a variety of functions through the serial RS232 or USB connection to a computer. 4.1 Auxiliary connector A 15-pin D subminiature connector (female), labelled Auxiliary Controls, is provided on the rear panel of the control unit to allow auxiliary control via TTL inputs of the shutters and ND wheels. The TTL input signals are OR d with the microcontroller signals and the front panel controls. A TTL High will open the corresponding shutter and a TTL Low will close the shutter. However, the microcontroller and front panel controls must be set to Closed to avoid overrides. The pinout of the 15-pin connector is shown in the following table. Pin Function Pin Function Pin Function Pin Function 1 Shutter 1 4 Shutter 4 7 Intensity -ve 10 - t used 2 Shutter 2 5 Shutter 5 8 Signal return 15 t used 3 Shutter 3 6 Intensity +ve 9 t used 4.2 Programmable TTL The LMM controller has BNC connections for both trigger in and trigger out. Both are used to coordinate the LMM with other equipment such as cameras and experimental apparatus. Sections and give a description of the functions, shows flowcharts for the triggers and gives detailed programming information In The trigger in BNC is used to control the on/off cycle for laser illumination based on externally generated conditions. A set of exposure states is defined, and the trigger steps through these states in order. The command structure is as follows Defining the exposure cycle Data: 1 byte specifies the number of exposure states, M, to cycle through (1 to 20), M bytes defining each of the exposure states using the same format as the Shutter Control command, and 2M bytes to specify the exposure times for each shutter state 8
11 The exposure times will be set in tenths of milliseconds and a zero will indicate to stay in that exposure state until the next trigger Configuring the trigger Data: 1 byte to enable/ disable the external trigger, 1 byte to specify N which is the number of trigger inputs to accumulate before initiating action, 1 byte specifying whether to step or cycle through the exposure states. When enabled, USB and manual control of the exposure is disabled. This means the shutters and ND wheels will not be controllable. The step mode will advance to the next exposure state on each trigger and then repeat the cycle when all states are complete. The exposure duration is determined by the set time after which the exposure state reverts to all closed while waiting for the next trigger. The cycle exposure mode will cycle through all the defined exposure states after each trigger. Further triggers will be disabled while cycling through exposure states Out The trigger out can be set in two modes, clock driven or state driven State driven A TTL pulse will be sent every time the exposure state is changed Clock Driven A TTL pulse is sent out at a regularly interval Configuring the 1 byte to enable/disable the trigger out, 1 byte to specify state/ clock driven, 2 bytes to specify the time between pulses in milliseconds between 0.1 milliseconds and 1 minute. Control of the ND wheels will be disabled if trigger out is enabled. This is a bit of a bother but is driven by limited resources on the microcontroller. 9
12 4.2.3 Flow Charts Figure 1: In, Cycle driven flow charts Shutters Closed In Shutter in State(0) If State Out Enabled Exposure Timer Exp and Trig Shutter in State(1) If State Out Enabled Exposure Timer Exp and Trig Shutter in State(N-1) If State Out Enabled Out 10
13 Exposure Timer Exp and Trig Shutters Closed If State Out Enabled Out Out In Ignore if Out pending or Cycle not finished Shutter in State(0) If State Out Enabled 11
14 Figure 2: In, State driven flowcharts te: Exposure Timer is reset if new trigger occurs before timer counts down Shutters Closed In Shutter in State(0) If State Out Enabled Exposure Timer Exposure? Shutters Closed Out In Ignore if Out pending Shutter in State(1) If State Out Enabled Exposure Timer Exposure? Out Shutters Closed 12
15 Shutters Closed In Shutter in State(0) If State Out Enabled Exposure Timer Exposure? Shutters Closed Out In Ignore if Out pending Shutter in State(1) If State Out Enabled Exposure Timer Exposure? Shutters Closed Out 13
16 Figure 3: Out flowchart Out Out 14
17 4.2.4 Programming These commands define the function of the trigger in and out BNCs from the control box. See the LMM5 programming guide for more information on sending commands to the LMM Exposure Configure Op-Code: 0x21 (33) Bytes Sent: 1+3M (1<=M<=20) Bytes: 1: # of exposure states (value of 1 to M) 2 to (M+1): exposure states (M+2) to (3M+1): exposure time Description: This command defines the exposure parameters that the unit cycles through upon receiving a trigger in. The number of exposure states determines the number of different shutter states that the unit will go through before repeating the cycle. The exposure states give the shutter states for each exposure in the cycle. The format is the same as the shutter control command so each bit in the byte indicates the state of the corresponding shutter. The exposure time gives a series of unsigned 2-byte integers that define the exposure time of each state. The exposure time is in 0.1 msec increments for a maximum of a bit more than 6.5 seconds. The behaviour of the exposure time depends on the trigger in mode (see below). In Step mode, the exposure time defines how long the shutter stays open before reverting to an all closed state. In Cycle mode, the exposure determines how long to wait before moving to the next state. 0x21;0x02;0x17;0x06;0x10;0x00;0x03;0xAD: Defines two exposure states- shutter 1 and 5 open then shutter 2 and 3 open with exposure times of sec and sec respectively In Configure Op-Code: 0x22 (34) Bytes Sent: 3 Bytes: 1: Enable(1)/Disable(0) In 2: # of trigger input before action 3: Define step(0) or cycle(1) trigger 15
18 Description: This command enables or disables the trigger in input and defines the trigger behaviour. Send 0 in the first byte to disable the trigger in and 1 to enable it. Step trigger is defined by a 0 in the third byte and Cycle mode by a 1. See trigger documentation for behaviour of each mode. The number of trigger inputs before action determines the number of trigger inputs to receive before taking action such as starting a state sequence or moving to the next state. 0x22;0x01;0x02;0x00: Enables a Step trigger and requires two trigger in events for each step. tes: In is positive edge TTL. There is a jitter of up to 50 microseconds in processing the trigger in. Motor control function and shutter control (manual and usb) are disabled while trigger is active. Motor control is deactivated due to limited timing resources and speed of the MCU and shutter control is deactivated since shutter states are determined by the exposure configuration Out Configure Op-Code: 0x23 (35) Bytes Sent: 4 Bytes: 1: Enable(1)/Disable(0) Out 2: State(0)/Clock(1) driven mode 3-4: Exposure Time Description: This commands enables the hardware trigger out. The trigger out can either be state driven so a trigger out occurs every time the shutter changes exposure state, or clock driven with the period between trigger outs is determined by exposure time. For state driven, the exposure time determines the delay from the state change to the trigger out. The exposure time is in 0.1 msec increments with a maximum of a bit more than 6.5 sec. The trigger out is a TTL pulse with a width of a few microseconds. 0x23;0x01;0x00;0x03;0xAD: Define a state driven trigger out with a delay of sec 0x23;0x01;0x01;0x00;0xC8: Define a clock driven trigger out at 50 Hz (20 msec delay) tes: Motor movement is disabled when trigger out is active Read In Configuration Op-Code: 0x25 (37) Bytes Sent: ne 16
19 Return: Returns the state of the trigger in setup in the same format as the trigger in configuration command Send 0x25 Receive 0x25;0x01;0x02;0x Read Out Configuration Op-Code: 0x26 (38) Bytes Sent: ne Return: Returns the state of the trigger out setup in the same format as the trigger out configuration command Send 0x26 Receive 0x26;0x01;0x00;0x03;0xAD: Read Exposure Configuration Op-Code: 0x27 (39) Bytes Sent: ne Return: Returns the exposure parameters in the same format as the exposure configuration command Send: 0x27 Receive: 0x27;0x02;0x17;0x06;0x10;0x00;0x03;0xAD 17
PRT3 Printer Module: ASCII Protocol Programming Instructions
PRT3 Printer Module: ASCII Protocol Programming Instructions We hope this product performs to your complete satisfaction. Should you have any questions or comments, please visit www.paradox.com and send
Inwall 4 Input / 4 Output Module
Inwall 4 Input / 4 Output Module IO44C02KNX Product Handbook Product: Inwall 4 Input / 4 Output Module Order Code: IO44C02KNX 1/27 INDEX 1. General Introduction... 3 2. Technical data... 3 2.1 Wiring Diagram...
SIMPLE EPROM PROGRAMMER. EPROM Programmer Design. Hardware
Page 1 of 5 A simple EPROM programmer is described here. It connects to a PC's parallel port and can program EPROMs from 2716 to 27512. The design can be expanded to program even larger EPROMs. DOS based
RS-485 Protocol Manual
RS-485 Protocol Manual Revision: 1.0 January 11, 2000 RS-485 Protocol Guidelines and Description Page i Table of Contents 1.0 COMMUNICATIONS BUS OVERVIEW... 1 2.0 DESIGN GUIDELINES... 1 2.1 Hardware Design
[F/T] [5] [KHz] [AMP] [3] [V] 4 ) To set DC offset to -2.5V press the following keys [OFS] [+/-] [2] [.] [5] [V]
FG085 minidds Function Generator Manual of Operation Applicable Models: 08501, 08501K, 08502K, 08503, 08503K Applicable Firmware Version: 1 ) 113-08501-100 or later (for U5) 2 ) 113-08502-030 or later
Single channel data transceiver module WIZ2-434
Single channel data transceiver module WIZ2-434 Available models: WIZ2-434-RS: data input by RS232 (±12V) logic, 9-15V supply WIZ2-434-RSB: same as above, but in a plastic shell. The WIZ2-434-x modules
Date Rev. Details Author
Jtech engineering ltd J - Te c h E n g i n e e ring, L t d. 11080 Bond Boulevard Delta BC V4E 1M7 Canada Tel: 604 543 6272 Fax: 604 543 6476 http://www.jtecheng.com AUTODIALER USER S MANUAL REVISION HISTORY
Modbus Communications for PanelView Terminals
User Guide Modbus Communications for PanelView Terminals Introduction This document describes how to connect and configure communications for the Modbus versions of the PanelView terminals. This document
Bluetooth + USB 16 Servo Controller [RKI-1005 & RKI-1205]
Bluetooth + USB 16 Servo Controller [RKI-1005 & RKI-1205] Users Manual Robokits India [email protected] http://www.robokitsworld.com Page 1 Bluetooth + USB 16 Servo Controller is used to control up to
Develop a Dallas 1-Wire Master Using the Z8F1680 Series of MCUs
Develop a Dallas 1-Wire Master Using the Z8F1680 Series of MCUs AN033101-0412 Abstract This describes how to interface the Dallas 1-Wire bus with Zilog s Z8F1680 Series of MCUs as master devices. The Z8F0880,
CHAPTER 11: Flip Flops
CHAPTER 11: Flip Flops In this chapter, you will be building the part of the circuit that controls the command sequencing. The required circuit must operate the counter and the memory chip. When the teach
TCP/IP MODULE CA-ETHR-A INSTALLATION MANUAL
TCP/IP MODULE CA-ETHR-A INSTALLATION MANUAL w w w. c d v g r o u p. c o m CA-ETHR-A: TCP/IP Module Installation Manual Page Table of Contents Introduction...5 Hardware Components... 6 Technical Specifications...
Controller Automation, Model II+
Controller Automation Page 2 of 2 Automation with the RADAK II+ power controller II+ I/O Points: Inputs 5 Programmable Digital inputs 2 Dedicated digital inputs (Channel select and External SCR control
CENTRONICS interface and Parallel Printer Port LPT
Course on BASCOM 8051 - (37) Theoretic/Practical course on BASCOM 8051 Programming. Author: DAMINO Salvatore. CENTRONICS interface and Parallel Printer Port LPT The Parallel Port, well known as LPT from
INSTRUCTION MANUAL for UNIBLITZ MODEL DM412 SHUTTER DRIVE MODULE
INSTRUCTION MANUAL for UNIBLITZ MODEL DM412 SHUTTER DRIVE MODULE VINCENT ASSOCIATES 803 LINDEN AVE. ROCHESTER, NEW YORK 14625 SERVICE/ORDERS (800) 828-6972 In NY State (585) 385-5930 Fax (585) 385-6004
Keep it Simple Timing
Keep it Simple Timing Support... 1 Introduction... 2 Turn On and Go... 3 Start Clock for Orienteering... 3 Pre Start Clock for Orienteering... 3 Real Time / Finish Clock... 3 Timer Clock... 4 Configuring
SenseLink TM. End-Point Controller. Addendum
SenseLink TM End-Point Controller Addendum MKS Instruments, Inc. Control & Information Technology Products Group 3350 Scott Blvd Bldg 4 Santa Clara, CA 95054 Main: 408.235.7620 Fax: 408.235.7625 SenseLink
T3 Mux M13 Multiplexer
T3 Mux M13 Multiplexer User Manual [Type the abstract of the document here. The abstract is typically a short summary of the contents of the document. Type the abstract of the document here. The abstract
The Answer to the 14 Most Frequently Asked Modbus Questions
Modbus Frequently Asked Questions WP-34-REV0-0609-1/7 The Answer to the 14 Most Frequently Asked Modbus Questions Exactly what is Modbus? Modbus is an open serial communications protocol widely used in
1. Learn about the 555 timer integrated circuit and applications 2. Apply the 555 timer to build an infrared (IR) transmitter and receiver
Electronics Exercise 2: The 555 Timer and its Applications Mechatronics Instructional Laboratory Woodruff School of Mechanical Engineering Georgia Institute of Technology Lab Director: I. Charles Ume,
DMX-K-DRV. Integrated Step Motor Driver + (Basic Controller) Manual
DMX-K-DRV Integrated Step Motor Driver + (Basic Controller) Manual DMX-K-DRV Manual page 1 rev 1.33 COPYRIGHT 2007 ARCUS, ALL RIGHTS RESERVED First edition, June 2007 ARCUS TECHNOLOGY copyrights this document.
2. Terminal arrangement. Default (PV display) (SV display) Communication protocol selection Selects the Communication protocol. Modbus ASCII mode:
COMMUNICATION INSTRUCTION MANUAL TEMPERATURE CONTROLLER KT4, KT8 and KT9 No.KTC1E6 2009.05 To prevent accidents arising from the misuse of this controller, please ensure the operator receives this manual.
NortechCommander Software Operating Manual MAN-00004 R6
NortechCommander Software Operating Manual MAN-00004 R6 If the equipment described herein bears the symbol, the said equipment complies with the applicable European Union Directive and Standards mentioned
APR-PRT3 Printer Module: C-Bus Programming Instructions
APR-PRT3 Printer Module: C-Bus Programming Instructions We hope this product performs to your complete satisfaction. Should you have any questions or comments, please visit www.paradox.com and send us
BLOCK OCCUPANCY DETECTOR WITH SEMAPHORE OPERATION BOD1/DAP4-BR
BLOCK OCCUPANCY DETECTOR WITH SEMAPHORE OPERATION BOD1/DAP4-BR This Block Occupancy Detector recognises the current drawn by moving trains within a block, and can operate a number of built-in programs
Ocean Controls RC Servo Motor Controller
Ocean Controls RC Servo Motor Controller RC Servo Motors: RC Servo motors are used in radio-controlled model cars and planes, robotics, special effects, test equipment and industrial automation. At the
Fingerprint Based Biometric Attendance System
Fingerprint Based Biometric Attendance System Team Members Vaibhav Shukla Ali Kazmi Amit Waghmare Ravi Ranka Email Id [email protected] [email protected] Contact Numbers 8097031667 9167689265
Serial Communications
Serial Communications 1 Serial Communication Introduction Serial communication buses Asynchronous and synchronous communication UART block diagram UART clock requirements Programming the UARTs Operation
STIM202 Evaluation Kit
Table of contents: 1 FEATURES... 2 2 GENERAL DESCRIPTIONS AND SYSTEM CONTENTS... 2 3 SYSTEM REQUIREMENTS... 2 4 GETTING STARTED... 3 4.1 INSTALLATION OF NI-SERIAL CABLE ASSEMBLY DRIVER... 3 4.2 INSTALLATION
Timeout The Crosspoint Status Request message has a timeout, which means that you need to wait 1 second in between request messages.
Network Control Protocol Important notes Binary Code The strings shown on the next pages are in binary coded format. Please be aware that any terminal program you may use to control a Network unit from
PFB366 Profibus-DP Gateway User Manual
PFB366 Profibus-DP Gateway User Manual Table of Contents CHAPTER 1 OVERVIEW...4 CHAPTER 2 INSTALLATION...5 MOUNTING...5 WIRING...6 Profibus-DP Interface...6 Serial Channel Interface...7 Wiring Examples...7
WA Manager Alarming System Management Software Windows 98, NT, XP, 2000 User Guide
WA Manager Alarming System Management Software Windows 98, NT, XP, 2000 User Guide Version 2.1, 4/2010 Disclaimer While every effort has been made to ensure that the information in this guide is accurate
Hagenberg Linz Steyr Wels. API Application Programming Interface
Hagenberg Linz Steyr Wels API Application Programming Interface Version 1.1 October 2015 FH OÖ Forschungs & Entwicklungs GmbH Franz-Fritsch-Strasse 11 / Top 3 4600 Wels Austria Research Center Hagenberg
Multi-Range Programmable DC Power Supplies 9115 Series
Data Sheet Multi-Range Programmable DC Power Supplies 1200 W / 3000 W Multi-Range DC Power Supplies Features & Benefits Any model can replace several supplies on your bench or in your rack. Unlike conventional
Data Acquisition Module with I2C interface «I2C-FLEXEL» User s Guide
Data Acquisition Module with I2C interface «I2C-FLEXEL» User s Guide Sensors LCD Real Time Clock/ Calendar DC Motors Buzzer LED dimming Relay control I2C-FLEXEL PS2 Keyboards Servo Motors IR Remote Control
AC-115 Compact Networked Single Door Controller. Installation and User Manual
AC-115 Compact Networked Single Controller Installation and User Manual December 2007 Table of Contents Table of Contents 1. Introduction...5 1.1 Key Features... 6 1.2 Technical Specifications... 7 2.
HOMEWORKS. RS-232 Protocol. Data Protocol for Communicating with Lutron's HOMEWORKS System
HOMEWORKS TM HOMEWORKS TM RS-3 Protocol Data Protocol for Communicating with Lutron's HOMEWORKS System HomeWorks RS-3 Protocol Overview HARDWARE OVERVIEW 3 wire RS-3C protocol 9 pin female D type connector
BIODEX ADDENDUM BIODEX EMG/ANALOG SIGNAL ACCESS CONFIGURATION UTILITY SOFTWARE FOR SYSTEM 3 REVISION 2 AND SYSTEM 4 DYNAMOMETERS
ADDENDUM BIODEX EMG/ANALOG SIGNAL ACCESS CONFIGURATION UTILITY SOFTWARE FOR SYSTEM 3 REVISION 2 AND SYSTEM 4 DYNAMOMETERS 830-000 835-000 840-000 850-000 BIODEX Biodex Medical Systems, Inc. 20 Ramsey Road,
BIT COMMANDER. Serial RS232 / RS485 to Ethernet Converter
BIT COMMANDER Serial RS232 / RS485 to Ethernet Converter (Part US2000A) Copyrights U.S. Converters 1 Contents Overview and Features... 3 Functions..5 TCP Server Mode... 5 Httpd Client Mode.5 TCP Auto mode....6
HCS-3300/3302/3304 USB Remote Programmable Laboratory Grade Switching Mode Power Supply
1. INTRODUCTION HCS-3300/3302/3304 USB Remote Programmable Laboratory Grade Switching Mode Power Supply User Manual This family of efficient, upgraded SMPS with small form factor, auto cross over CV CC,
Technical Manual. FAN COIL CONTROLLER COOLING or HEATING ANALOG or PWM Art. 119914 631001A
COOLING or HEATING ANALOG or PWM Art. 119914 631001A TOTAL AUTOMATION GENERAL TRADING CO. LLC SUITE NO.506, LE SOLARIUM OFFICE TOWER, SILICON OASIS, DUBAI. UAE. Tel. +971 4 392 6860, Fax. +971 4 392 6850
SYMETRIX SOLUTIONS: TECH TIP August 2015
String Output Modules The purpose of this document is to provide an understanding of operation and configuration of the two different String Output modules available within SymNet Composer. The two different
MidiStream. UHF Wireless MIDI System Operating Manual
MidiStream UHF Wireless MIDI System Operating Manual Introduction Congratulations on your purchase of the MidiStream UHF wireless MIDI system. The MidiStream system is very easy to use, but please take
Chapter 4 T1 Interface Card
Chapter 4 T1 Interface Card GENERAL This chapter describes DTE interface options that may be required if application requirements change. It also describes software configuration for the T1 interface card.
Flexible Active Shutter Control Interface using the MC1323x
Freescale Semiconductor Document Number: AN4353 Application Note Rev. 0, 9/2011 Flexible Active Shutter Control Interface using the MC1323x by: Dennis Lui Freescale Hong Kong 1 Introduction This application
AVR151: Setup and Use of the SPI. Introduction. Features. Atmel AVR 8-bit Microcontroller APPLICATION NOTE
Atmel AVR 8-bit Microcontroller AVR151: Setup and Use of the SPI APPLICATION NOTE Introduction This application note describes how to set up and use the on-chip Serial Peripheral Interface (SPI) of the
SUDT AccessPort TM Advanced Terminal / Monitor / Debugger Version 1.37 User Manual
SUDT AccessPort TM Advanced Terminal / Monitor / Debugger Version 1.37 User Manual Version 1.0 - January 20, 2015 CHANGE HISTORY Version Date Description of Changes 1.0 January 20, 2015 Initial Publication
Programming and Using the Courier V.Everything Modem for Remote Operation of DDF6000
Programming and Using the Courier V.Everything Modem for Remote Operation of DDF6000 1.0 Introduction A Technical Application Note from Doppler System July 5, 1999 Version 3.x of the DDF6000, running version
Design of Strong-motion Monitoring System for Dam-reservoir D s e i s gn of Stro r ng-mo m tion Monito t ri r ng Syst s em
Design of Strong-motion Monitoring System for Dam-reservo eservoir Li Caihua Li Xiaojun Institute of Engineering Mechanics, China Earthquake Administration China Harbin 150080 Abstract: One strong-motion
Disturbance Recoder SPCR 8C27. Product Guide
Issued: April 1999 Status: Updated Version: C/26.04.2006 Data subject to change without notice Features Versatile digital disturbance recorder module for recording various phenomena in the electric power
RS-232 Communications Using BobCAD-CAM. RS-232 Introduction
RS-232 Introduction Rs-232 is a method used for transferring programs to and from the CNC machine controller using a serial cable. BobCAD-CAM includes software for both sending and receiving and running
Low Speed Modems for Dial and Leased Circuits 2400E-2 (Stand Alone) 2400R-2 (Rack Mount) 2400E-4 (Stand Alone) 2400R-4 (Rack Mount)
Low Speed Modems for Dial and Leased Circuits 2400E-2 (Stand Alone) 2400R-2 (Rack Mount) 2400E-4 (Stand Alone) 2400R-4 (Rack Mount) QUALITY COMMUNICATIONS PRODUCTS Made in the U.S.A. 11-1010-002 INTRODUCTION
Nemo 96HD/HD+ MODBUS
18/12/12 Pagina 1 di 28 MULTIFUNCTION FIRMWARE 2.30 Nemo 96HD/HD+ MODBUS COMMUNICATION PROTOCOL CONTENTS 1.0 ABSTRACT 2.0 DATA MESSAGE DESCRIPTION 2.1 Parameters description 2.2 Data format 2.3 Description
XR-500 [Receipt Printer User s Manual ]
XR-500 [Receipt Printer User s Manual ] All specifications are subjected to change without notice TABLE OF CONTENTS 1. Parts Identifications 2 2. Setting up the printer 3 2.1 Unpacking 3 2.2 Connecting
Model 5511 Filler Controller User s Manual Version 1.1 October 2011
Thompson Scale Company WEIGHING SYSTEMS & PACKAGING MACHINERY CONTROLS 2758 Bingle Road Houston, Texas 77055 Phone: 713/932-9071 Fax: 713/932-9379 www.thompsonscale.com Model 5511 Filler Controller User
TASCAM SS-CDR200/SS-R200 CONTROL I/O Terminals RS-232C Protocol Specifications
TASCAM CONTROL I/O Terminals RS-232C Protocol Specifications TEAC Corporation - 1 - ATTENTION TEAC Corporation ("TEAC") licenses you the protocol specified in this document, assuming that you agree to
Multi-Range Programmable DC Power Supplies 9115 Series
Data Sheet 1200 W Multi-Range DC Power Supplies Features & Benefits Any 9115 series model can replace several supplies on your bench or in your rack. Unlike conventional supplies with fixed output ratings,
TBS Dominator 5G8 Receiver
TBS Dominator 5G8 Receiver Integrated video receiver for Fatshark Dominator fpv goggles. Compatible with Dominator, Dominator V2 and Dominator HD Revision 2015-05-23 The TBS DOMINATOR 5G8 video receiver
Softstarters. Type PSTX Fieldbus communication, Built-in Modbus RTU. 1SFC132089M0201 April 2015 1SFC132089M0201 1
Softstarters Type PSTX Fieldbus communication, Built-in Modbus RTU 1SFC132089M0201 April 2015 1SFC132089M0201 1 1 Modbus RTU The Modbus protocol is a fieldbus protocol that provides full control and status
iloq P10S.10/20 Programming device User's Guide
iloq P10S.10/20 Programming device User's Guide CONTENTS CONTENTS... 2 GENERAL... 3 USING THE PROGRAMMING DEVICE... 5 Starting the programming device... 5 Programming of locks... 5 Programming of keys...
E-i. Section E. Code Formatting. E/D = Enable/Disable T/DNT = Transmit/Do Not Transmit EX/DNEX = Expand/Do Not Expand
Section E Code Formatting E/D = Enable/Disable T/DNT = Transmit/Do Not Transmit EX/DNEX = Expand/Do Not Expand C/DNC = Convert/Do Not Convert E/DNE = Enable/Do Not Enable T/DNT UPC-A Check Digit (E - 1)
Part Number Description Packages available
Features 3 digital I/O Serial Data output Connects directly to RF Modules Easy Enc / Dec Pairing Function Minimal External Components Required Performs all encoding/decoding of data for Reliable Operation.
ABB i-bus EIB Shutter Actuators JA/S 2.230.1, JA/S 4.230.1, JA/S 8.230.1, JA/S 4.230.1M, JA/S 8.230.1M, JA/S 4.24.1
Product Manual ABB i-bus EIB Shutter Actuators JA/S 2.230.1, JA/S 4.230.1, JA/S 8.230.1, JA/S 4.230.1M, JA/S 8.230.1M, JA/S 4.24.1 Intelligent Installation Systems Contents Page 1 Introduction.......................................
Software User Guide UG-461
Software User Guide UG-461 One Technology Way P.O. Box 9106 Norwood, MA 02062-9106, U.S.A. Tel: 781.329.4700 Fax: 781.461.3113 www.analog.com ezlinx icoupler Isolated Interface Development Environment
INTELLIGENT CONTROL MODULE SA-2000-II HARDWARE MANUAL. Access Technologies International, Inc.
SA-2000-II HARDWARE MANUAL Access Technologies International, Inc. 1 Table of Contents 1. Introduction 3 2. Features 3 3. Specification 4 4. Identifying Supplied Parts 4 5. Panel Description 5 6. Connection
EA-200. http://world.casio.com/edu/ Technical Reference. Contents. Sampling... 2 Analog Sampling... 3 Memory... 3 Pulse Sampling...
E Contents EA-200 Technical Reference Sampling... 2 Analog Sampling... 3 Memory... 3 Pulse Sampling... 4 Command Tables... 5 Command 1: Channel Settings... 9 Command 3: Sampling and Trigger Settings...
USER GUIDE EDBG. Description
USER GUIDE EDBG Description The Atmel Embedded Debugger (EDBG) is an onboard debugger for integration into development kits with Atmel MCUs. In addition to programming and debugging support through Atmel
The Analyst RS422/RS232 Tester. With. VTR, Monitor, and Data Logging Option (LOG2) User Manual
12843 Foothill Blvd., Suite D Sylmar, CA 91342 818 898 3380 voice 818 898 3360 fax www.dnfcontrolscom The Analyst RS422/RS232 Tester With VTR, Monitor, and Data Logging Option (LOG2) User Manual Manual
OVERVIEW Playbacks: Shortcuts: Memories: Data Entry Wheels: Touchpad: Master and Blackout:
OVERVIEW The MIDIcon is a USB MIDI control panel designed to work alongside the Elation lighting software packages. The Midicon is USB powered and uses the USB class drivers so that no driver needs to
LADDER LOGIC/ FLOWCHART PROGRAMMING DIFFERENCES AND EXAMPLES
page 1/10 This document is designed as a quick-start primer to assist industrial automation programmers who are familiar with PLCs and Relay Ladder Logic programming to better understand the corresponding
MODULE BOUSSOLE ÉLECTRONIQUE CMPS03 Référence : 0660-3
MODULE BOUSSOLE ÉLECTRONIQUE CMPS03 Référence : 0660-3 CMPS03 Magnetic Compass. Voltage : 5v only required Current : 20mA Typ. Resolution : 0.1 Degree Accuracy : 3-4 degrees approx. after calibration Output
MANUAL FOR RX700 LR and NR
MANUAL FOR RX700 LR and NR 2013, November 11 Revision/ updates Date, updates, and person Revision 1.2 03-12-2013, By Patrick M Affected pages, ETC ALL Content Revision/ updates... 1 Preface... 2 Technical
CONCEPT1 RS232 COMMUNICATION
Concept 1 RS-232 Communication Communication with Concept 1 via RS-232 is done with simple ASCII Commands and Replies. The port settings are 19200Baud, 8bits, no parity and 1 stop bit. The physical connection
APPLICATION NOTE # Using Sage SMOS for VoIP Testing, IP Phone to IP Phone TABLE OF CONTENTS
Product: 930A L3 Communications Test Set 935AT Communications Test Set APPLICATION NOTE # Using Sage SMOS for VoIP Testing, IP Phone to IP Phone TABLE OF CONTENTS Introduction... 2 Configuring 935AT #1
FG085 08501, 08501K, 08502K, 08503, 08503K, 08504K
FG085 minidds Function Generator Manual of Operation Applicable Models: 08501, 08501K, 08502K, 08503, 08503K, 08504K Applicable Firmware Version: 1 ) 113-08501-130 or later (for U5) 2 ) 113-08502-050 or
Tebis application software
Tebis application software Input products / ON / OFF output / RF dimmer Electrical / Mechanical characteristics: see product user manual Product reference Product designation TP device RF devices WYC81xQ
Publication 0300129-02 Rev. C SIEMENS. (S5 Communications) Reference
Publication 0300129-02 Rev. C SIEMENS (S5 Communications) Reference IMPORTANT NOTES 1. READ ALL OF THE INFORMATION CONTAINED IN THIS MANUAL BEFORE YOU INSTALL THE PRODUCT. 2. The information contained
MAX6683 Evaluation System/Evaluation Kit
19-2343; Rev 1; 3/07 MAX6683 Evaluation System/Evaluation Kit General Description The MAX6683 evaluation system (EV system) consists of a MAX6683 evaluation kit (EV kit) and a companion Maxim CMODUSB board.
Servo Motors (SensorDAQ only) Evaluation copy. Vernier Digital Control Unit (DCU) LabQuest or LabPro power supply
Servo Motors (SensorDAQ only) Project 7 Servos are small, relatively inexpensive motors known for their ability to provide a large torque or turning force. They draw current proportional to the mechanical
User Manual. AS-Interface Programmer
AS-Interface Programmer Notice: RESTRICTIONS THE ZMD AS-INTERFACE PROGRAMMER HARDWARE AND ZMD AS-INTERFACE PROGRAMMER SOFTWARE IS DESIGNED FOR IC EVALUATION, LABORATORY SETUP AND MODULE DEVELOPMENT ONLY.
2011, The McGraw-Hill Companies, Inc. Chapter 3
Chapter 3 3.1 Decimal System The radix or base of a number system determines the total number of different symbols or digits used by that system. The decimal system has a base of 10 with the digits 0 through
LTM-1338B. Plus Communications Manual
LTM-1338B Plus Communications Manual 2000. Best Power, Necedah, Wisconsin All rights reserved. Best Power The System Setup option from the Main Menu on the front panel is passwordprotected. The default
RN-XV-RD2 Evaluation Board
RN-XV-RD2 Evaluation Board 2012 Roving Networks. All rights reserved. -1.01Version 1.0 9/28/2012 USER MANUAL OVERVIEW This document describes the hardware and software setup for Roving Networks RN-XV-RD2
Data sheet Wireless UART firmware version 4.02
Data sheet Wireless UART firmware version 4.02 BLUETOOTH is a trademark owned by Bluetooth SIG, Inc., U.S.A. and licensed to Free2move Rev: 22 December 2008 Table of contents 1 GENERAL INFORMATION...4
Programming A PLC. Standard Instructions
Programming A PLC STEP 7-Micro/WIN32 is the program software used with the S7-2 PLC to create the PLC operating program. STEP 7 consists of a number of instructions that must be arranged in a logical order
22.302 Experiment 5. Strain Gage Measurements
22.302 Experiment 5 Strain Gage Measurements Introduction The design of components for many engineering systems is based on the application of theoretical models. The accuracy of these models can be verified
MP-RS232 CPM Photoncounting Module with integrated RS232 PC Interface
MP-RS232 CPM Photoncounting Module with integrated RS232 PC Interface Operating Instructions DETECTION SOLUTIONS Introduction The Photon Counting Unit MPXXX- RS232 series is designed for applications in
PM1122 INT DIGITAL INTERFACE REMOTE
PM1122 INT DIGITAL INTERFACE REMOTE PM1122 INT front panel description: 1. Clear wireless remotes knob: push this button for more than 2 seconds to clear the list of all assigned wireless remote settings
Welcome to the Introduction to Controller Area Network web seminar My name is William Stuart, and I am a Applications Engineer for the Automotive
Welcome to the Introduction to Controller Area Network web seminar My name is William Stuart, and I am a Applications Engineer for the Automotive Products Group within Microchip. This web seminar today
EXPERIMENT 2 TRAFFIC LIGHT CONTROL SYSTEM FOR AN INTERSECTION USING S7-300 PLC
YEDITEPE UNIVERSITY ENGINEERING & ARCHITECTURE FACULTY INDUSTRIAL ELECTRONICS LABORATORY EE 432 INDUSTRIAL ELECTRONICS EXPERIMENT 2 TRAFFIC LIGHT CONTROL SYSTEM FOR AN INTERSECTION USING S7-300 PLC Introduction:
LDG Electronics External Meter Serial Communications Protocol Specification
M1000 METER PROTOCOL SPECIFICATION MANUAL REV A LDG Electronics External Meter Serial Communications Protocol Specification LDG Electronics 1445 Parran Road St. Leonard MD 20685-2903 USA Phone: 410-586-2177
SDN INSTRUCTIONS 07/10, Ver 1.2. Somfy Digital Network (SDN) Installation and Programming
Somfy Digital Network (SDN) Installation and Programming SSoomffyy SSyysst teemss IInncc.. 1 Table of Contents 1 General Information and Features... 3 1.1 ILT2 Motor... 3 1.2 SDN Switches... 4 1.3 ILT2
Objectives. Basics of Serial Communication. Simplex vs Duplex. CMPE328 Microprocessors (Spring 2007-08) Serial Interfacing. By Dr.
CMPE328 Microprocessors (Spring 27-8) Serial Interfacing By Dr. Mehmet Bodur Objectives Upon completion of this chapter, you will be able to: List the advantages of serial communication over parallel communication
RS232C < - > RS485 CONVERTER S MANUAL. Model: LD15U. Phone: 91-79-4002 4896 / 97 / 98 (M) 0-98253-50221 www.interfaceproducts.info
RS232C < - > RS485 CONVERTER S MANUAL Model: LD15U INTRODUCTION Milestone s model LD-15U is a RS232 to RS 485 converter is designed for highspeed data transmission between computer system and or peripherals
ABB i-bus KNX Fan Coil Controller FC/S 1.1
Product manual ABB i-bus KNX Fan Coil Controller FC/S 1.1 Intelligent Installation Systems Contents Page 1 Introduction... 2 2 Device technology... 3 3 Application and planning 3.1 Heating, ventilation
How To Use A Power Supply On A Powerline 2.2 (Ai)
KNX/EIB Product documentation Issue: 05.08.2010 629x1220 Push button sensor 3 comfort 1-gang Push button sensor 3 comfort 2-gang (1+1) Push button sensor 3 comfort 3-gang Push button sensor 3 comfort 4-gang
Implementing SPI Master and Slave Functionality Using the Z8 Encore! F083A
Application Note Implementing SPI Master and Slave Functionality Using the Z8 Encore! F083A AN026701-0308 Abstract This application note demonstrates a method of implementing the Serial Peripheral Interface
How to read this guide
How to read this guide The following shows the symbols used in this Quick start guide with descriptions and examples. Symbol Description Example P oint Reference Caution [ ] This symbol explains information
HDMI Switch USER MANUAL VS481A
HDMI Switch USER MANUAL VS481A FCC Information This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed
CM6700 Matrix Switcher/Controller
CM6700 Matrix Switcher/Controller Installation/ Operation Manual C523M-H (6/05) Pelco 3500 Pelco Way Clovis, CA 93612-5699 USA www.pelco.com In North America and Canada: Tel (800) 289-9100 FAX (800) 289-9150