CIBSE ASHRAE Group. Data Centre Energy Efficiency: Who, What, Why, When, Where & How



Similar documents
How to Build a Data Centre Cooling Budget. Ian Cathcart

Energy Efficiency Opportunities in Federal High Performance Computing Data Centers

Increasing Energ y Efficiency In Data Centers

Heat Recovery from Data Centres Conference Designing Energy Efficient Data Centres

Specialty Environment Design Mission Critical Facilities

Recommendations for Measuring and Reporting Overall Data Center Efficiency

Case Study: Innovative Energy Efficiency Approaches in NOAA s Environmental Security Computing Center in Fairmont, West Virginia

Data Centre Cooling Air Performance Metrics

Data Center Industry Leaders Reach Agreement on Guiding Principles for Energy Efficiency Metrics

CURBING THE COST OF DATA CENTER COOLING. Charles B. Kensky, PE, LEED AP BD+C, CEA Executive Vice President Bala Consulting Engineers

Legacy Data Centres Upgrading the cooling capabilities What are the options?

The New Data Center Cooling Paradigm The Tiered Approach

Understanding Power Usage Effectiveness (PUE) & Data Center Infrastructure Management (DCIM)

Energy Recovery Systems for the Efficient Cooling of Data Centers using Absorption Chillers and Renewable Energy Resources

Recommendations for Measuring and Reporting Overall Data Center Efficiency

Analysis of data centre cooling energy efficiency

How green is your data center?

Case Study: Opportunities to Improve Energy Efficiency in Three Federal Data Centers

ICT and the Green Data Centre

Trends in Data Center Design ASHRAE Leads the Way to Large Energy Savings

European Code of Conduct for Data Centre. Presentation of the Awards 2013

GREEN FIELD DATA CENTER DESIGN WATER COOLING FOR MAXIMUM EFFICIENCY. Shlomo Novotny, Vice President and Chief Technology Officer, Vette Corp.

FEAR Model - Review Cell Module Block

Recommendation For Incorporating Data Center Specific Sustainability Best Practices into EO13514 Implementation

Managing Cooling Capacity & Redundancy In Data Centers Today

Paul Oliver Sales Director. Paul Oliver, Airedale Tom Absalom, JCA

Guide to Minimizing Compressor-based Cooling in Data Centers

Managing Data Centre Heat Issues

Dealing with Thermal Issues in Data Center Universal Aisle Containment

Increasing Data Center Efficiency through Metering and Monitoring Power Usage

Challenges In Intelligent Management Of Power And Cooling Towards Sustainable Data Centre

Presentation Outline. Common Terms / Concepts HVAC Building Blocks. Links. Plant Level Building Blocks. Air Distribution Building Blocks

Green Data Centre Design

Measuring Power in your Data Center: The Roadmap to your PUE and Carbon Footprint

Data Center Equipment Power Trends

DataCenter 2020: first results for energy-optimization at existing data centers

University of St Andrews. Energy Efficient Data Centre Cooling

Holistic, Energy Efficient Datacentre Cardiff Going Green Can Save Money

Managing Power Usage with Energy Efficiency Metrics: The Available Me...

Energy Efficiency in New and Existing Data Centers-Where the Opportunities May Lie

Combining Cold Aisle Containment with Intelligent Control to Optimize Data Center Cooling Efficiency

Minimising Data Centre Total Cost of Ownership Through Energy Efficiency Analysis

Re Engineering to a "Green" Data Center, with Measurable ROI

Energy Efficient Data Centre at Imperial College. M. Okan Kibaroglu IT Production Services Manager Imperial College London.

Improving Data Center Energy Efficiency Through Environmental Optimization

Data Center Environments

Data Center Design Guide featuring Water-Side Economizer Solutions. with Dynamic Economizer Cooling

BRUNS-PAK Presents MARK S. EVANKO, Principal

BCA-IDA Green Mark for Existing Data Centres Version EDC/1.0

The Mission Critical Data Center Understand Complexity Improve Performance

Data Center Energy Use, Metrics and Rating Systems

GUIDE TO ICT SERVER ROOM ENERGY EFFICIENCY. Public Sector ICT Special Working Group

Direct Fresh Air Free Cooling of Data Centres

Pursuing Operational Excellence. Better Data Center Management Through the Use of Metrics

Energy Efficient High-tech Buildings

Free Cooling in Data Centers. John Speck, RCDD, DCDC JFC Solutions

Digital Realty Data Center Solutions Digital Chicago Datacampus Franklin Park, Illinois Owner: Digital Realty Trust Engineer of Record: ESD Architect

Guideline for Water and Energy Considerations During Federal Data Center Consolidations

Optimization of energy consumption in HPC centers: Energy Efficiency Project of Castile and Leon Supercomputing Center - FCSCL

Infrastructure & Cities Sector

Environmental Data Center Management and Monitoring

Energy Efficiency Best Practice Guide Data Centre and IT Facilities

Power Usage Effectiveness (PUE) & Data Center Infrastructure Efficiency (DCiE) Progress

High Density Data Centers Fraught with Peril. Richard A. Greco, Principal EYP Mission Critical Facilities, Inc.

I-STUTE Project - WP2.3 Data Centre Cooling. Project Review Meeting 4, Lancaster University, 2 nd July 2014

HPPR Data Center Improvements Projects Towards Energy Efficiency (CFD Analysis, Monitoring, etc.)

Data Center 2020: Delivering high density in the Data Center; efficiently and reliably

Reducing Data Center Energy Consumption

How Does Your Data Center Measure Up? Energy Efficiency Metrics and Benchmarks for Data Center Infrastructure Systems

Reducing the Annual Cost of a Telecommunications Data Center

Data Center Components Overview

Server room guide helps energy managers reduce server consumption

Server Room Thermal Assessment

Reducing Data Center Loads for a Large-Scale, Net Zero Office Building

IMPROVING DATA CENTER EFFICIENCY AND CAPACITY WITH AISLE CONTAINMENT

7 Best Practices for Increasing Efficiency, Availability and Capacity. XXXX XXXXXXXX Liebert North America

DATA CENTER COOLING INNOVATIVE COOLING TECHNOLOGIES FOR YOUR DATA CENTER

Unleashing Stranded Power and Cooling Data

Data Center Energy Profiler Questions Checklist

General Recommendations for a Federal Data Center Energy Management Dashboard Display

Defining Quality. Building Comfort. Precision. Air Conditioning

Top 5 Trends in Data Center Energy Efficiency

Energy and Cost Analysis of Rittal Corporation Liquid Cooled Package

Liquid Cooling Solutions for DATA CENTERS - R.M.IYENGAR BLUESTAR LIMITED.

The Effect of Data Centre Environment on IT Reliability & Energy Consumption

World s Greenest High Performance Data Center

Raising Inlet Temperatures in the Data Centre

Imperial College 3 March 2009 Green Data Centers: An Overview

IT Equipment Design Evolution & Data Center Operation Optimization. Don Beaty Roger Schmidt

Metering and Managing University of Sheffield Data Centres. Chris Cartledge Independent Consultant

AERMEC DATA CENTRE SOLUTIONS THE COMPLETE RANGE OF AERMEC SOLUTIONS FOR DATA CENTRES

Guidance for Calculation of Efficiency (PUE) in Data Centers

I-STUTE Project - WP2.3 Data Centre Cooling. Project Review Meeting 8, Loughborough University, 29 th June 2015

Improving Data Center Efficiency with Rack or Row Cooling Devices:

Data Center Energy Efficiency. SC07 Birds of a Feather November, 2007 Bill Tschudi wftschudi@lbl.gov

Data Centre Energy Efficiency Operating for Optimisation Robert M Pe / Sept. 20, 2012 National Energy Efficiency Conference Singapore

NetApp Data Center Design

Oil Submersion Cooling for Todayʼs Data Centers. An analysis of the technology and its business implications

Engineers Ireland Cost of Data Centre Operation/Ownership. 14 th March, 2013 Robert Bath Digital Realty

Enabling an agile Data Centre in a (Fr)agile market

Transcription:

CIBSE ASHRAE Group Data Centre Energy Efficiency: Who, What, Why, When, Where & How

Presenters Don Beaty PE, FASHRAE Founder, President & Managing Director DLB Associates Consulting Engineers Paul Finch CEng, FIMechE, MASHRAE Senior Director, Technical Design & Construction Digital Realty 2

Bio s Don Beaty has over 30 years experience in consulting engineering and founded DLB Associates Consulting Engineers in 1980. He is a licensed professional engineer in over 40 states and has international licenses as well. Don co-founded and was the first chair of ASHRAE Technical Committee TC 9.9 and currently serves as its Publications Chair. He is a frequent keynote speaker on behalf of ASHRAE TC 9.9 for the data centre industry, having presented over 100 times and in more than 25 countries on various data centre-centric topics. Paul Finch is a senior engineering and construction executive and has extensive global experience across the full spectrum of development management and complex engineering led capital projects and operations, with a particular focus on the design, construction and operation of data centres, technical real estate and high dependency mission critical assets and infrastructure projects, across the telecommunications, technology and banking & financial services sectors. Paul is a Voting Committee Board Member of ASHRAE Technical Committee (TC) 9.9 - Mission Critical Facilities, Data Centres, Technology Spaces and Electronic Equipment. 3

Table of Contents 1. Some Data Centre Basics 2. Key Trends within the Data Centre Industry 3. Energy Standards & Regulations 4. Measurement of Data Centre Energy 5. Best Practices for Efficient Operation 6. Innovative Concepts & Solutions 7. Further Reading & Reference Publications 8. Q&A 4

1 Some Data Centre Basics 5

Some Data Centre Basics Data Centre Graphical Overview 6

Some Data Centre Basics Data Centre Occupants and Fixtures, Furnishings & Equipment (FF&E) Occupants FF&E FF&E Where Are The Occupants? They Cannot Be Seen; They Are Software Conventional Buildings Human Occupants Data Centres Software Occupants 7

Some Data Centre Basics Computer Cabinets & Racks 8

Some Data Centre Basics Server Configurations Tower Server (tall & narrow) Freestanding 1U Server (short & wide) Rack Mounted Blade Server (square) 9

Some Data Centre Basics Hardware, System Software & Application Software 10

2 Key Trends in the Data Centre Industry

Key Trends in the Data Centre Industry 2000 & 2005 IT Equipment Power Predictive Trends Uptime Institute Graphic Modified By DLB ASHRAE Graphic Modified By DLB Thermal Management Consortium in 2000: Published Through The Uptime Institute ASHRAE 2005 Publication: Datacom Equipment Power Trends & Cooling Applications History Validated these Trends 12

Key Trends in the Data Centre Industry Data Center Generational Impact 2007 to 2011 Metric Generation 1 Generation 2 Generation 3 Generation 4 Generation 1 to 4 have the SAME IT Performance Comparative Change (4U, 4 Processor) IBM Generation 1 (Year 1 Baseline) Generation 4 (Year 4) Generation 1 to 4 Comparison IT Performance 100% 100% SAME IT Power per Rack 100% 119% + 19% Rack Count 100% (60) 13% (8) - 87% Total IT Power 100% 18% - 82% Space Required 100% 15% - 85% Cooling Required 100% 20% - 80% 13

Key Trends in the Data Centre Industry ASHRAE Psychrometric Chart 2011 Classes A1 and A2 are EXACTLY the SAME as previous Classes 1 & 2: Apply to new AND legacy equipment New Classes A3 and A4 do NOT include legacy equipment 14

Key Trends in the Data Centre Industry Volume Server Power Demand & Performance Growth Volume Server Power Demand & Performance Growth (excludes extreme low energy servers) Volume Server CAGR Growth in 3 Years Growth in 5 Years Power Demand Growth 2 to 6% 5 to 20% 10 to 30% Performance Growth 25 to 30% 90 to 120% 200 250% Compounded Annual Growth Rate (CAGR) Growth Projections are Rounded 15

Key Trends in the Data Centre Industry Volume Server Power Trends to 2020 (fully configured, fully utilized max load) Height No. of Sockets Heat Load / Chassis (Watts) Heat Load / 42U Rack Increase 2010 to 2010 2015 2020 2010 2015 2020 2020 1U 1s 255 290 330 10,710 12,180 13,860 29% 2s 600 735 870 25,200 30,870 36,540 45% 4s 1,000 1,100 1,200 42,000 46,200 50,400 20% 2U 2s 750 1,100 1,250 15,750 23,100 26,250 67% 4s 1,400 1,800 2,000 29,400 37,800 42,000 43% 4U 2s 2,300 3,100 3,300 23,000 31,000 33,000 43% 7U (Blade) 2s 5,500 6,500 7,500 33,000 39,000 45,000 36% 9U (Blade) 2s 6,500 8,000 9,500 26,000 32,000 38,000 46% Market Requirements force IT manufacturers to maximize performance/volume (creating high heat load/rack). These rack heat loads will result in increased focus on improving data center ventilation solutions and localized liquid cooling solutions High Risk to Generalize; One Shoe Definitely Does NOT Fit All 16

Key Trends in the Data Centre Industry Volume Server Power Trends - Simple Adjustment Factor Example Adjustment Factor 1.00 (Original Value) 0.50 (Your Data Center) Volume Server Configuration Heat Load / Chassis (Watts) Heat Load / 42U Rack 2010 2015 2020 2010 2015 2020 1U, 2s 600 735 870 25,200 30,870 36,540 1U, 2s 300 368 435 12,600 15,435 18,270 How to adjust the published Trends for your environment: 1) Trend Chart Value for a 1U, 2s Volume Server in 2010: 600 Watts 2) ACTUAL MEASURED Value for YOUR 1U, 2s Server: 300 Watts 3) Calculated Adjustment Factor for YOUR 1U, 2s Server = 300 Watts / 600 Watts = 0.50 17

3 Energy Standards & Regulations

Energy Standards & Regulations ASHRAE Standard 90.1-2013 Purpose Scope Definitions, Abbreviations, and Acronyms Administration and Enforcement Building Envelope Heating, Ventilating, and Air Conditioning Service Water Heating Power Lighting Other Equipment Energy Cost Budget Method 19

Energy Standards & Regulations ASHRAE Standard 127-2012 Purpose Scope Definitions Classification Rating Requirements Conformance References 20

Energy Standards & Regulations ASHRAE Thermal Guidelines for Data Processing Environments 3rd Edition Introduction Environmental Guidelines for Air-Cooled Equip. Environmental Guidelines for Liquid-Cooled Equip. Facility Temperature & Humidity Measurement Equipment Placement & Airflow Patterns Equip. Manufacturers Heat & Airflow Reporting Appendices A J 21

4 Measurement of Data Centre Energy

Measurement of Data Centre Energy PUE Basics PUE: Power Usage Effectiveness ppue: Partial Power Usage Effectiveness PUE defined by The Green Grid (TGG) PUE is an annualised metric considering kwh not kw PUE can NEVER be <1.0 PUE does NOT receive credit for waste heat repurposes EUE (Energy Reuse Effectiveness) does consider waste heat 23

Measurement of Data Centre Energy PUE & ppue Definition 24

Measurement of Data Centre Energy PUE Example 600MWh Transformer (25MWh) Zone B 575MWh 500MWh UPS (25MWh) Example: PUE (Zone A) = 600/475 = 1.26 ppue (Zone B) = 500/475 = 1.05 Zone A Chiller (75MWh) IT Equipment Cooling 475MWh 25

Measurement of Data Centre Energy ppue Example 2700MWh 2500MWh Transformer (200MWh) (200MWh) Chiller Zone B UPS IT Equipment (100MWh) 1500MWh Example: 500MWh PUE (Zone A) = 2700/2000 = 1.35 ppue 1 (Zone B) = 1700/1500 = 1.13 ppue 2 (Zone C) = 700/500 = 1.40 IT Equipment Chiller Zone A (200MWh) Zone C 26

Measurement of Data Centre Energy PUE Measurement Three defined levels of PUE measurement being: PUE 1 (Level 1: Basic) UPS Output, Utility Input, Monthly/Weekly PUE 2 (Level 2: Intermediate) PDU Outputs, Utility Input, Daily/hourly PUE 3 (Level 3: Advanced) IT Equipment Input, Utility Input, 15 minutes 27

5 Best Practices for Efficient Operation

Best Practices for Efficient Operation Design and Operational Opportunities Energy Management: measure performance, plant & equipment right-sizing. Environmental Conditions: optimise supply temperature and humidity control. Air Flow Management: improve return air management, separate hot and cold airstreams, Improve underfloor pressure management, Optimise IT cabinet airflow, Improve CRAH, CRAC, AHU efficiency. Cooling Plant: variable speed drives, cooling plant strategies, increase water efficiency, optimise pumping control, use of waste heat, optimise chilled water and condenser water supply temperatures, improve pumping efficiency, direct expansion vs. chilled water Power: improve UPS efficiency, improve transformer efficiency, minimise power distribution routes. Lighting: Improve lighting efficiency. IT Equipment: implement server virtualisation, optimise data storage, enable power management features, specify high efficiency power supplies, IT infrastructure right-sizing. 29

6 Innovative Concepts & Solutions 30

Innovative Concepts & Solutions Degree of Applicability Varies from Project to Project Thermal Guidelines for Data Processing Environments (2011) adoption of the Allowable Range & X-Factors Compressor-less cooling solutions Application of in-direct outside air High Performance Computing (HPC) liquid cooling technologies full oil emersion, processor heat-sink and closed-coupled heat exchangers Decentralised UPS Fine granularity phasing (e.g. one row at a time) Minimise the number of end-to-end voltage transitions 31

7 Further Reading 32

Further Reading & Reference Publications ASHRAE Datacom Series www.tc99.ashraetcs.org www.ashrae.org 33

8 Question & Answers

THANK YOU Don Beaty PE, FASHRAE Founder, President & Managing Director +1 732 927 5000 dbeaty@dlbassociates.com 265 Industrial Way West, Eatontown, NJ 07724, USA +1 732 774 2000 www.dlbassociates.com Paul Finch CEng, FIMechE, MASHRAE Senior Director, Technical Design & Construction +44 (0) 7984 912 258 pfinch@digitalrealty.com Level 7, 40 Gracechurch Street, London EC3V 0BT, UK +44 (0)20 7954 9121 www.digitalrealty.com 35