DigitalFlow XMT868i. Panametrics Liquid Flow Ultrasonic Transmitter. GE Sensing & Inspection Technologies. Applications. Features



Similar documents
DigitalFlow GF868. Panametrics Flare Gas Mass Ultrasonic Flowmeter with Extended Performance Range. GE Sensing & Inspection Technologies.

DigitalFlow GF868 Panametrics Ultrasonic Flare Gas Mass Flowmeter. GE Sensing. Features. Applications

Flow Measurement Solutions for Thermal Cracking Processes

Sentinel LCT. Panametrics Ultrasonic Flowmeter for Liquid Custody Transfer Measurement. GE Measurement & Control Solutions. Benefits.

PORTABLE FLOW METER KITS TDS-100H

Certified according to DIN EN ISO 9001 Technical Datasheet KVO Series Vortex Flow Meter

Easily installed and simple to set up, Flow Pulse uses an acoustic technique never before seen in flow measurement to deliver reliable results across

Energy and Flow Measurement for Hydronic Systems

O C M III. Open Channel Flow Monitor

RHE12. Hazardous Area Coriolis Mass Flow Transmitter. Features. Applications. Benefits

How To Use A Flowmeter

XMT868 ULTRASONIC LIQUID FLOW TRANSMITTER

DREXELBROOK. USonic-R Series. Ultrasonic Level Measurement System. User Friendly

For Multi-Parameter Meters see mvx

MTI10 Insertion and MTL10 In-line Thermal Mass Flowmeter and Temperature Transmitter

Electro-Magnetic Flowmeters COPA-XT 2-Wire DT43

Measurement. SITRANS F US Inline. Transmitter FUS080/FUE080 4/219

Non-invasive CLAMP-ON ultrasonic flowmeter for liquids

Electronic Flow Switches

Regards from the Team at Rheology Solutions.

Series DFMT Digital Paddlewheel Flowmeter

F ox W hi t e Paper. Reduce Energy Costs and Enhance Emissions Monitoring Systems

UTM10 Series Ultrasonic Transit-time Flowmeters

BM SERIES WAVE COMPACT 6.3 GHZ CW SERIES PULSE RADAR LEVEL INSTRUMENTS (6.3 GHz)

IFC 070 Technical Datasheet

LLB-OCMFM 2000 PORTABLE DOPPLER AREA-VELOCITY FLOWMETER

Plastic tube flowmeters Series PT/PS

CALDON LEFM 380Ci Gas Ultrasonic Flow Meter. Integrating experience, proven technology and innovation

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

Engineered for Accuracy and Simple Installation VANTAGE Ultrasonic Transit-Time Flowmeter

Digital inductive conductivity transmitter

How To Use A Ds340 (Dsp)

COMBIMASS. Technical Data COMBIMASS eco-bio +

SITRANS F flowmeters SITRANS F M

Open Channel & Partially Filled Pipe Ultrasonic Flow Meters

Model AT868 AquaTrans Ultrasonic Flow Transmitter for Water (1- & 2-Channel)

The L&J Engineering Model MCG 1500SFI Servo Gauge

Open channel & partially filled pipe Ultrasonic flow meters

713 Open Channel Flowmeter and Transmitter. All-in-one package for open channel flow measurement.

Certified according to DIN EN ISO 9001 Technical Datasheet TRICOR Series Mass Flow Meters

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

Temperature & Humidity SMS Alert Controller

Unidirectional Transmitter/ Receiver Units Introduction

Figure 1 Flexim F601 parts 1) Control console 2) Ultrasonic transducers 3) Magnetic transducer mounting rails 4) RTD temperature probes (PT100)

OPTIMASS 6000 Technical Datasheet

Interface Level And Point Level Analyzers & Sensors

3DLevelScanner II TECHNICAL DATA SHEET

Thermal Mass Flow Meter (Series MST)

The Unique Accelabar Flow Meter

Intelligent chart recorder for compressed air and gases. Measurement - control - indication - alarm - recording - evaluation

SITRANS F flowmeters SITRANS FUS080. SITRANS FUS380/FUE380/SONOCAL /179. flow sensor pipe, 4 transducers/transducer cables and a transmitter

SECTION 16002C CAMPUS CENTRAL METERING SYSTEM DESIGN CRITERIA 1. General

NEW. EVEN MORE data acquisition and test stand automation

Electromagnetic Flow Meter

Sanitary Type Electronic Flow Switches

RTD Temperature Probe for the Food/Pharmaceutical Industry

AT500 Magnetostrictive Level Transmitter. Compact magnetostrictive liquid level transmitter for direct insertion K-TEK Products

API Marine. BMS Presentation. Ballast Measurement Systems

Application/Connection Examples

Mobrey open channel flow measurement systems

Take total control of your HVAC system with cost-saving flow and thermal energy meters

FLARE MONITORS FLARE MONITOR (FM) PILOT MONITOR (PM) FLAME INTENSITY (FI)

ULTRASONIC THICKNESS GAUGE TT100/110/120/130

Flow Measurement Options for Pipeline and Open Channel Flow

Ultrasonic Gas Meters for Industrial and Commercial Applications. Ohio Gas Association Technical Seminar March 27-28,2014

Service catalog Flow products

Short Form Catalogue. Alarm Systems. Reliable Supervision and Control

SELECT MOUNT MONITOR

FCI M180 Series: Custom Engineered Flow and Level Sensors for OEM Applications

Level Plus. Magnetostrictive Liquid-Level Sensors with Temposonics Technology. M-Series Model MR Transmitter with Analog Output.

Flow switches Series AD/VH

Grant Agreement No SFERA. Solar Facilities for the European Research Area SEVENTH FRAMEWORK PROGRAMME. Capacities Specific Programme

Micro Motion 3098 Gas Specific Gravity Meter

Triple Waveband Infra-Red Flame Detection

Thermatel Model TA1 Mass Flow Transmitter

CAMS. Combustion Airflow Management System. Proven solutions for a tough industry

In-Line Electronic Flow Switches

Easy drop down menu allows quick set up, the clear large display offers a choice of menus and the interface echo can be constantly seen if needed.

Typical Aluminum GFM Mass Flow Meter

INDIAN STANDARDS FOR NATURAL GAS PIPELINE SYSTEM

WaterMAG. Electromagnetic Flowmeter for Water Applications. Model MCB10A OVERVIEW APPLICATIONS FEATURES. No. SS2-MCB

APT3200 SMART PRESSURE TRANSMITTER. Application Areas: For Gauge And Absolute Pressure Measurement

Mobrey Ultrasonic. MSP900SH Level and MSP900FH Flow Transmitters. Product Data Sheet February 2015 IP2032, Rev BA

A project to optimise quality and energy efficiency must include metering

ELECTROMAGNETIC FLOWMETER COMPACT

3500/22M Transient Data Interface

920 Series. Dual-point heat-tracing control system. Product overview. 920*E4FWL*SIS302*SS3102 shown

Technical data. General specifications. Indicators/operating means. 30 Hz Multiplex operation 30 Hz / n, n = number of sensors, n 5

Instructions Manual. Electromagnetic sensor Series FLOMID FX. instrumentation for fluids. R-MI-FlomidFX Rev.: 0 English version

S300 Series Dust Monitors

Firmware version: 1.10 Issue: 7 AUTODIALER GD30.2. Instruction Manual

GE Measurement & Control. DigitalFlow XGF868i. Flare Gas Mass Flow Ultrasonic Transmitter. Startup Guide

SHARKY 775 COMPACT ENERGY METER ULTRASONIC

Micro Motion 7829 Visconic Viscosity Meter

Energy Depot GmbH PRODUCT AND APPLICATION GUIDE. Total Monitoring Solution for PV. Delivering Solutions for Energy Management

USB-500 Series Stand-Alone, Low-Cost Data Loggers

Fluxi 2000/TZ Turbine Gas Meter

Remote monitoring & control solutions for cathodic protection rectifier

FCI ST75 Series Flow Meters

A New Generation in Magnetic Level Indication

Transcription:

GE Sensing & Inspection Technologies DigitalFlow XMT868i Panametrics Liquid Flow Ultrasonic Transmitter The DigitalFlow XMT868i liquid flow transmitter is a complete ultrasonic flow metering system for measurement of: Applications Hydrocarbon liquids Liquefied natural gas (LNG) Crude oil Lubricating oils Diesel fuel oils Solvents Water and wastewater Hot/chilled water Chemicals Features Economical non-intrusive flow measurement Hazardous (classified) location certifications Simple set-up and installation Suitable for wide range of pipe sizes and materials Two-channel/two-path version available Beverages Other liquids

Panametrics Liquid Flow Ultrasonic Transmitter The DigitalFlow XMT868i ultrasonic flow transmitter combines state-of-the-art flow measurement capability with a low-cost transmitter package that can be installed right at the process measurement point. The XMT868i carries appropriate certification for for installation in hazardous (classified) locations commonly found in petrochemical and chemical processing environments. The all-digital XMT868i has no moving parts, requires minimal maintenance and provides long-term, drift-free operation. An onboard microprocessor provides exclusive digital signal coding and correlation detection routines, automatic adjustment to changing fluid properties, and dynamically-configured operating software to simplify programming. Improved Programming Capability The DigitalFlow XMT868i introduces an infrared six-button keypad to allow safe programming and diagnostics verification in your hazardous (classified) location. There is no need to open the case to use a PC to program and no need for an additional handheld programmer. Just touch the glass of the XMT868i and the IR buttons will sense your touch. If you prefer your PC interface, the DigitalFlow XMT868i maintains its RS232 capability, providing full access to the meter s diagnostics and programming using PanaView software. PanaView also provides continuous logging capability. Wetted or Clamp-On Transducers Ultrasonic flow transducers are classified as either wetted or non-wetted (clamp-on). Clamp-on transducers are clamped onto the outside of the pipe and never come into contact with the process fluid. Wetted transducers are mounted into the pipe or flowcell in direct contact with the process fluid. Clamp-on transducers offer maximum convenience, flexibility and a low installation cost compared to traditional flow metering technologies. With proper installation, wetted transducers provide maximum accuracy (better than 0.5 percent of reading) in most applications. The DigitalFlow XMT868i can be used with a variety of wetted solutions including the PanaFlow system. The PanaFlow meter system relies on the XMT868i as an integral component to simplify installation. A DigitalFlow XMT868i is easily mounted to the top of a PanaFlow system and is shipped ready to install. Dual-Channel Version Reduces Costs and Improves Performance The optional dual-channel/dual-path model can be userconfigured for a variety of applications. It can be set up to measure flow in two separate pipes with one meter to reduce the cost-per-measurement point. To minimize the effects of flow profile distortions, flow swirl and cross flow, and for maximum accuracy, you can install the two sets of transducers on the same pipe. DigitalFlow XMT868i shown with clamp-on transducers

DigitalFlow XMT868i Flow Transmitter Uses Transit-Time Flow Measurement Technique Fluid flow Flowmeter transducers Ultrasonic signal path Transit-time flow measurement technique In this method, two transducers serve as both ultrasonic signal generators and receivers. When mounted on a pipe, they are in acoustic communication with each other, meaning the second transducer can receive ultrasonic signals transmitted by the first transducer and vice versa. In operation, each transducer functions as a transmitter, generating a certain number of acoustic pulses, and then as a receiver for an identical number of pulses. The time interval between transmission and reception of the ultrasonic signals is measured in both directions. When the liquid in the pipe is not flowing, the transit-time downstream equals the transit-time upstream. When the liquid is flowing, the transit-time downstream is less than the transit-time upstream. The difference between the downstream and upstream transit times is proportional to the velocity of the flowing liquid, and its sign indicates the direction of flow. Automatically Adjusts to Changing Fluid Properties Standard in all DigitalFlow XMT868i transmit ters, our unique Automatic Tracking Window (ATW ) feature ensures accurate flow measurements even when fluid properties are unknown or changing. Like the seek mode on your car stereo, ATW dynamically sweeps the receiver window whenever the sound speed of the fluid changes. This powerful feature lets you measure flow when the fluid sound speed is unknown, is changing due to large temperature shifts, or when a new liquid starts to flow in a multiproduct pipeline. ATW works for both clamp-on and wetted transducer applications by searching for a reliable ultrasonic receive signal. It does this by varying the time between the transmit signal and the receive signal window until the receive signal is found. The tracking window automatically sweeps through a range of time intervals based on the minimum and maximum expected sound speeds programmed by the user. The window moves (tracks) in response to changes in the fluid sound speed. Once the optimal signal is found, ATW locks onto it until another large change in sound speed occurs. When this happens, ATW returns to the seek mode until the optimal signal is found again. Transmit signal Variable time interval Receive signal Tracking window locked onto receive signal Time ATW ensures accuracy when fluid conditions change Range of tracking window

XMT868i Specifications Operation and Performance Fluid Types Acoustically conductive fluids, including most clean liquids, and many liquids with entrained solids or gas bubbles. Maximum void fraction depends on transducer, interrogation carrier frequency, path length and pipe configuration. Pipe Sizes Clamp-on transducers: 0.5 in to 300 in (12.7 mm to 7.6 m) and larger Wetted transducers: 1 in to 200 in (25.4 mm to 5 m) and larger Pipe Wall Thickness Up to 3 in (76.2 mm) Pipe Materials All metals and most plastics. Consult GE for concrete, composite materials, and highly corroded or lined pipes. Flow Accuracy (Velocity) ±0.5% of reading (achievable with process calibration) Typical Clamp-On Flow Accuracy (Velocity) Pipe ID>6 in (150 mm): ±1% to 2% of reading Pipe ID<6 in (150 mm): ±2% to 5% of reading Typical Wetted Flow Accuracy (Velocity) ±1% of reading Accuracy depends on pipe size, installation and whether measurement is one-path or two-path. Repeatability ±0.1% to 0.3% of reading Range (Bidirectional) 40 to 40 ft/s ( 12.2 to 12.2 m/s) Rangeability (Overall) 400:1 Electronics Flow Measurement Patented Correlation Transit-Time mode Enclosures Standard: Epoxy-coated aluminum weatherproof Type 4X/IP66 Class I, Divison 1, Groups B, C & D; Class II, Groups E, F & G; Class III Flameproof II 2 GD EEx d IIC T5/T6 Optional: Stainless steel Dimensions Standard: Weight 10 lb (4.5 kg), size (h x d) 8.2 in x 6.6 in (208 mm x 168 mm) Channels Standard: One channel Optional: Two channels (for two pipes or two-path averaging) Display Optional: two-line x 16-character backlit LCD display, configurable to display up to four measurement parameters in sequence Keypad Built-in infrared, six-button keypad, for full functionality operation Power Supplies Standard: 90-260 VAC Optional: 12 to 28 VDC, ± 5% Power Consumption 20W maximum Operating Temperature -4 F to 140 F (-20 C to +60 C) Storage Temperature 67 F to 167 F ( 55 C to 75 C) Standard Inputs/Outputs Two 0/4 to 20 ma isolated outputs, 600 S maximum load Specifications assume a fully developed flow profile (typically 10 diameters upstream and 5 diameters downstream of straight pipe run) and flow velocity greater than 1 ft/s (0.3 m/s). Measurement Parameters Volumetric flow, totalized flow and flow velocity

Optional Inputs/Outputs All analog and digital I/O are available in specific combinations. Consult GE for available option cards. Two additional 0/4 to 20 ma isolated outputs, 1000 Ω maximum load Two 4 to 20 ma isolated inputs, 24-VDC loop power Two or four isolated, three-wire RTD (temperature) inputs, 148 F to 662 F ( 100 C to 350 C), 100 S platinum Two or four pulse or frequency outputs, optically isolated, 3A maximum, 100 VDC maximum, 1W maximum, from DC to 10 khz maximum Alarm relays Digital Interfaces Standard: RS232 Optional: RS485 (multiuser) Optional: HART protocol Optional: Modbus protocol Optional: Foundation Fieldbus Optional: OPC server Optional: Ethernet Data Logging Standard: None Optional: Memory capacity (linear and/or circular type) to log up to 150,000 flow data points European Compliance System complies with EMC Directive 89/336/EEC, 73/23/ EEC LVD (Installation Category II, Pollution Degree 2) and transducers comply with PED 97/23/EC for DN<25 Clamp-On Ultrasonic Flow Transducers Temperature Ranges C-RS Transducers:-40 to 300 F (-40 to 150 C)C-PT High Temperature: -20 to 410 F (-29 to 210 C) OKS Special Application: -310 F to 572 F ( 190 C to 300 C) Mountings Stainless steel chain or strap, welded or magnetic clamping fixtures Area Classifications Standard: General purpose Optional: Weatherproof Type 4/IP65 Optional: Class I, Division 1, Groups B, C & D; Class II, Groups E, F & G; Class III Optional: Flameproof II 2 G EEx md IIC T6 T3 Optional: Submersible Wetted Ultrasonic Flow Transducers Temperature Ranges Standard: 40 F to 212 F ( 40 C to 100 C) Optional (overall range): 310 F to 1112 F ( 190 C to 600 C) Pressure Ranges Standard: 0 to 3000 psig (1 to 207 bar) Optional: Higher pressures on request Materials Standard: Stainless steel Optional (for Pan-Adapta Plugs): Titanium, Hastelloy alloy, Monel alloy, duplex, CPVC, PVDF and others Pan-Adapta plugs allow installation and removal of wetted transducers without interrupting the process or emptying the pipe. Temperature Ranges Standard: 40 F to 212 F ( 40 C to 100 C) Optional (overall range): 310 F to 1112 F (-190 C to 600 C) Pressure Ranges Standard: 0 psig to 3000 psig (1 bar to 207 bar) Optional: Higher pressures on request Materials Standard: Stainless steel Optional (for Pan-Adapta Plugs): Titanium, Hastelloy alloy, Monel alloy, duplex, CPVC, PVDF and others Pan-Adapta plugs allow installation and removal of wetted transducers without interrupting the process or emptying the pipe. Process Connections Standard: 1 in or 3/8 in NPTM Optional: RF flanged, socket weld, fuse bond and others Mountings Flanged flowcell, hot tap or cold tap Area Classifications Standard: General purpose Optional: Weatherproof Type 4/IP65 Optional: Class I, Division 1, Groups B, C & D; Class II, Groups E, F & G; Class III Optional: Flameproof II 2 G EEx d IIC T6 Optional: Submersible

Transducer Cables Standard: One pair of coaxial cables, type RG62 AU, or as specified for transducer type Optional: Lengths up to 1000 ft (330 m) maximum High-Temperature and High-Pressure Ultrasonic Flow Transducers Bundle Waveguide Technology System transducer and holder (see BWT System specifications) Energy Measurement Calculates energy flow rate and totalized energy. Requires optional RTD or analog I/O board. Temperature Transducers Loop-powered, three-wire, platinum RTDs; clamp-on and wetted (thermo-well) types are available Accuracy ±0.15 C with wetted RTDs (matched pairs) Range -4 F to 500 F (-20C to 260 C) The accuracy of the energy measurement is a combination of the accuracy of the associated flow and temperature measurements. 1% to 2% of reading is typical for calibrated systems. Not all extremes of parameters can be achieved simultaneously. Additional Options PanaView PC Interface Software The DigitalFlow XMT868i communicates with a PC through a serial interface and Windows operating systems. Consult the manual for details on sites, logs and other operations with a PC.

XMT868i Application Notes in Brief Ultrasonic Flowmeter Saves Money Over Mag Meter A sewerage/wastewater facility found that installing a GE clamp-on ultrasonic flowmeter offered excellent performance and accuracy and was far less expensive than installing a new mag meter. When comparing cost of a new 30 in (750 mm) mag meter to be installed on their cast iron line to that of a two-path GE meter, the water treatment plant decided that the ultrasonic meter was a bargain. The 30 in (750 mm) mag required the line to be shut down for installation and major piping work needed to be done. It was estimated that it would take several days to get the meter running. The GE meter was easily installed to existing piping without ever shutting down the pipe and installation was complete within a day. Additional Options PanaView PC Interface Software The DigitalFlow XMT868i communicates with a PC through a serial interface and Windows operating systems. Consult the manual for details on sites, logs and other operations with a PC. 710 F (376 C) Resid Line? No Problem. With the DigitalFlow XMT868i combined with the Bundle Wafeguide Technology System from GE, you can measure cryogenic fluids like LNG or the demanding temperatures of coker resid lines that can run hotter than 700 F (371 C). Ultrasonic flowmeters will not cause pressure drop and have no impulse lines to plug, making them a great solution for difficult fluids. Even though most ultrasonic manufacturers flowmeters can only handle up to 500 F (260 C), GE s BWT systems have been able to reach up to 1000 F (537 C). The unique design removes the piezoelectric element from the extreme temperatures by using wave guide technology. The transducer can even be swapped out under operating conditions. One customer has installed 16 units, replacing their wedge meters, and has had them operating maintenance free for more than five years. Accuracy ±0.15 C with wetted RTDs (matched pairs) Range 4 F to 500 F ( 20C to 260 C) The accuracy of the energy measurement is a combination of the accuracy of the associated flow and temperature measurements. 1% to 2% of reading is typical for calibrated systems. Not all extremes of parameters can be achieved simultaneously. Bundle Waveguide Technology System

www.gesensinginspection.com 920-170B 2008 General Electric Company. All Rights Reserved. Specifications are subject to change without notice. GE is a registered trademark of General Electric Company. Other company or product names mentioned in this document may be trademarks or registered trademarks of their respective companies, which are not affiliated with GE.