Flow switches Series AD/VH
|
|
|
- Alfred Colin Higgins
- 10 years ago
- Views:
Transcription
1 Flow switches Flow switch and indicator for liquids and gases Suitable for clear, opaque or turbid liquids (series AD & VH), and for gases (series AD) Flow switching by means of magnetic coupling, watertight, no contact between process fluid and switching, indicator or transmitter systems Suitable for installation in horizontal or vertical pipes Robust construction Scales available for H 2O, air, oil, etc. (series AD) Flow rate (for liquids): - Series AD: l/min - Series VH: m 3 /h Accuracy for series AD: ±5% f.s. Connections: - Series AD: ¼... 2 ½ BSP / NPT - Series VH: G1 / 1 NPT, to be inserted on a DN32... DN500 pipe : - Series AD: EN (AISI 316L), aluminium, brass - Series VH: EN (AISI 316L), PTFE Flow switching: - 1 reed switch (series AD & VH) - 2 reed switches (only series AD) - 1 or 2 inductive switches (only series AD) All switches for series AD are ATEX Ex ia IIC T4...T6 Ga / Ex ia IIIC T85ºC Da certified Options for model ADI15: - Local flow indication - Electronic transmitter with 4-20 ma output for safe or hazardous area (Ex ia IIC T4...T6 Ga / Ex ia IIIC T85ºC Da protection, ATEX certified). HART protocol available on request 1
2 TORK-AD HYDRAULIC / VH Series AD Working principle A spring M keeps a disk B in zero flow rate position. When the fluid flows through the disk at a specific speed, a force is made on the disk B, moving it to an equilibrium position. The distance covered by B depends on: - The force of the fluid flow F. - The relationship between areas A & B. - The force in opposition of the spring C. The equilibrium between forces F and the one generated by C defines the position of the disk B, equivalent to flow rate. The disk B, which contains a magnet M, acts over the switches and/or the local indicator. Technical data Accuracy: ±5% full scale Scale range: according to flow rate chart on page 4 Scales in l/h, l/min, l/s, m 3 /h, %, etc. Connections: ¼... 2 ½ BSP / NPT : - Brass from ¼ to 2 - Aluminium from 1 ¼ to 2 ½ - EN (AISI 316L) on request Fluid temperature: -20ºC ºC (max. allowable 120ºC) Working pressure: PN16 (others on request) Vertical or horizontal mounting, as per customer s request Ex ia IIC T4...T6 Ga / Ex ia IIIC T85ºC Da ATEX certificate Operation Vertical upwards flow (BD) Vertical downwards flow (DAB) Horizontal flow from left to right (ED) Horizontal flow from right to left (DES) Applications Machine or processes cooling Hydraulic and lubrication circuits Thermal oil circuits Gas flow control Mechanical fasteners cooling control Limit switches and transmitters Reed switches: SPDT potential free. Polyamide housing and IP65 connector /1A = 1 reed switch /2A = 2 reed switches Reed switch technical data: - ADR01: for sizes ¼ & ½ : 0,25 A 175 VDC 5 W - ADR11: for sizes ¾ to 2½ : 1 A 250 V 60 VA M1-AMD1... 2: adjustable inductive switches (+ relays on request) TH6... TH6H: 4-20 ma 2-wire transmitter HART protocol for model TH6H All switches and transmitters are ATEX available Ex ia IIC T4...T6 Ga / Ex ia IIIC T85ºC Da version AD15 ADI15 with one or two reed switches local flow indication optionally with: - one or two reed switches - one or two inductive switches ma transmitter TH6 transmitter 2
3 Flow switches ¼ ¼... 2 ½ Nº Description ¼ ¼... 2 ½ 1 Body Brass / AISI 316L / Anodized aluminium * 2 Disk 3 Magnet Ferrite ** 4 Switch Polycarbonate - PVC - NBR 5 Washer AISI 316L 6 Spring AISI Housing Polycarbonate - Coated aluminium 8 Screw AISI Gasket NBR *** * available for each size: ¼... 1 : brass, AISI 316L 1 ¼ 2 : brass, AISI 316L, anodized aluminium 2 ½ : AISI 316L, anodized aluminium ** magnet with plastic coating for applications with corrosive liquids on request *** other materials on request 3
4 TORK-AD HYDRAULIC / VH Dimensions Flow ranges AD15 ADI15 R (BSP / NPT) ¼ ½ Flow scales l/min water ¾ " ¼" ½ " ½" * Equivalent flow ranges for air at 1 bar abs 20ºC in Nl/min: l/min H 2O x 8 (approx.) Mounting Vertical upwards AD15/BD ADI15/BD ADI15+TH6 Vertical downwards AD15/DAB ADI15/DAB R (BSP / NPT) A B C F L Weight (kg) ¼ ½ ¾ " ¼" ½ " Ø ½" Ø All dimensions in mm Horizontal / Left to right Horizontal / Right to left AD15/ED ADI15/ED AD15/DES ADI15/DES 4
5 Flow switches Model AD15 Flow switch with min-max flow rate reed switches. Vertical or horizontal mounting, as per customer s request. Adjustable reed switch for the full flow scale, mounted in a polyamide housing, IP65 ingress protection. Flow scale in l/h, l/min, l/s, m 3 /h, %, etc. Model ADI15 Local flow indicator, with optional min-max flow rate reed switches, adjustable for the full flow scale and mounted in an IP65 polyamide housing; and/or adjustable inductive switches, mounted in the indicator housing. Vertical or horizontal mounting, as per customer s request. Aluminium indicator housing with polycarbonate cover, IP65 ingress protection, graduated scale in flow rate units, reading by means of indicating needle. Flow and reed switch scale in l/h, l/min, l/s, m 3 /h, %, etc. Model ADI15 + TH6 Same characteristics as model ADI15, including electronic transmitter with 2-wire 4-20 ma output. Limit switches and transmitters Adjustable limit switch M1-AMD Optional for model ADI15. NAMUR (EN ) 3.5 mm slot type inductive detector activated by vane, mounted in the indicator housing. M1-AMD1 2: 1 2 adjustable limit switches Power supply: 8 VDC Ambient temperature: -25 C C ATEX certification Ex ia IIC T4...T6 Ga / Ex ia IIIC T85ºC Da Control relay (on request) NAMUR (EN ) for 1 or 2 inductive detectors. Power supply: VAC Hz VDC Input: NAMUR Ex ia IIC Output: 1 or 2 relay contacts Output rating: 2 A 250 VAC 100 VA / 1 A 24 VDC Ambient temperature: -20 C C Transmitter TH6 Power supply: 2-wire system, VDC Power consumption: max. 20 ma Analog output (4-20 ma): - Error: < 0,6% of the magnet position - Maximum load in 4-20 ma loop: 1.1 kω (with 36 VDC power supply) Ambient temperature: -5ºC ºC Transmitter connector: Packing gland M12x1.5 Optional: ATEX certification Ex ia IIC T4...T6 Ga / Ex ia IIIC T85ºC Da, with model TH6 Ex Optional: HART protocol, with model TH6H 5
6 TORK-AD HYDRAULIC / VH Series VH Working principle A liquid flows inside a pipe fast enough to move a paddle, which at the same time moves a permanent magnet that acts over the reed switch. The magnet-reed switch system is isolated from the liquid. The flow switching point is positioned between 30º and 45º from the zero position. Applications Hydraulic and heating-cooling circuits Chemical, petrochemical and pulp & paper industry Water treatment, power plants Swimming pools & fire protection systems VH35 / SS... PTFE VH37 / SS BD VH39 / PTFE BD horizontal pipe vertical pipe with upwards flow, with spring vertical pipe with upwards flow, with magnetic spring Technical data Flow detection by means of oscillating paddle SPDT potential free reed switch, mounted in the body, not wetted by the liquid Connections: G1 (1 NPT on request) : EN (AISI 316L), PTFE Others on request Fluid temperature: -40ºC ºC (max. allowable 150ºC) Working pressure: - AISI 316L body: PN25 (others on request) - PTFE body: PN10 Mounting: horizontal or vertical upwards pipe Nº Description VH / SS VH / PTFE Operation Vertical upwards flow (BD) Horizontal flow from left to right Horizontal flow from right to left Limit switches Reed switch: potential free switch Contact rating: Maximum switching power: 5W Maximum switching voltage: 175 VDC Maximum switching current: 0.25 A Electrical connection: connector IP65 DIN A Suitable for hazardous area, considered as Simple apparatus 1 Connector Polyamide 2 Screw AISI Gasket NBR 4 Connector base Polyamide 5 Gasket NBR 6 Spring AISI Body AISI 316L PTFE 8 Magnet holder PVDF PTFE 9 Reed switch Glass 10 Pin AISI 316 PTFE 11 Paddle AISI 316L PTFE 6
7 Flow switches Dimensions Switching flow rates DN mm DN inch Switching flow rate (1) m³/h L mm 32 1 ¼ ½ ½ (1) Approximate flow rates Mounting Horizontal / left-right or right-left: model VH35 VH35 / SS VH35 / SS VH35 / PTFE Vertical upwards: model VH37 / 39 BD VH37 / SS BD VH35 / PTFE VH39 / PTFE BD 7
Plastic tube flowmeters Series PT/PS
Plastic tube flowmeters Variable area flowmeter for liquids and gases Low cost, excellent readability and light weight Simple installation (flanged, threaded or socket ends for solvent or fusion welding
Non-invasive CLAMP-ON ultrasonic flowmeter for liquids
Non-invasive CLAMP-ON ultrasonic flowmeter for liquids Model CU100: non-invasive installation flowmeter, with transducers installed outside the pipe Installation in horizontal or vertical pipe Easy and
RHE12. Hazardous Area Coriolis Mass Flow Transmitter. Features. Applications. Benefits
RHE12 Hazardous Area Coriolis Mass Flow Transmitter Features Field mounting Compact, pressure safe housing ATEX and CSA approvals for installation in hazardous areas 24 VDC power supply Configurable analog
How To Use A Flowmeter
INLINE flowmeter for continuous flow measurement Economic integration in pipe systems without any additional piping 3-wire frequency pulse version to directly interface with PLC s (both PNP and NPN) Connection
Compact pressure switch Flameproof enclosure Ex d Model PCA
Mechatronic pressure measurement Compact pressure switch Flameproof enclosure Ex d Model PCA WIKA data sheet PV 33.31 for further approvals see page 4 Process Compact Series Applications Pressure monitoring
Plastic Flow Meters for gases & liquids, using TROGAMID* & POLYSULFONE Technology
Plastic Flow Meters for gases & liquids, using TROGAMID* & POYSUFONE Technology Applications Monitoring & Control of processes for: Water & Waste Water Treatment Chemical, Petrochemical & Paper Pharmaceutical,
Digital inductive conductivity transmitter
Digital inductive conductivity transmitter Optimal solution for conductivity measurements in difficult fluids (polluted, dirty,...) PEEK/PPA version for CIP applications Large range of process connections
SITRANS F flowmeters SITRANS F M
Overview Integration The complete flowmeter consists of a flow sensor and an associated transmitter MAG 5000, 6000 or 6000 I. The flexible communication concept USM II simplifies integration and update
DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor
DMP Industrial Pressure Transmitter for Low Pressure Stainless Steel Sensor accuracy according to IEC 60770: standard: 0.5 % FSO option: 0.5 / 0. % FSO from 0... 00 mbar up to 0... 40 bar Output signals
Safety at a high level!
SIKA Level Switch SIKA Level Switch Safety at a high level! Convincing Advantages easy and reliable method to monitor fluid levels proven float principle easy side installation using threads ¾" or ½" BSP
Inductive sensor NI10-M18-Y1X-H1141
ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 as per IEC 61508 Threaded barrel, M18 x 1 Chrome-plated brass DC 2-wire, nom. 8.2 VDC Output acc. to DIN EN 60947-5-6 (NA- MUR) M12
Fluid Level Gauge Fluid Level Sensor Temperature Switch FSA / FSK / TS
Fluid Level Gauge Fluid Level Sensor Temperature Switch FSA / FSK / TS up to size 381; to PN 0.5; to T = 80 C 1. Description 1.1. General FSA fluid level gauges, FSK fluid level sensors and TS temperature
OEM Pressure Transmitters for heavy-duty applications, Type MBS 1200 and MBS 1250
MAKING MODERN LIVING POSSIBLE Data sheet OEM Pressure Transmitters for heavy-duty applications, Type MBS 1200 and MBS 1250 The compact OEM pressure transmitter programme is designed for use in severe hydraulic
Control- and feedback head for integrated mounting on Robolux valves Type 2036
Control- and feedback head for integrated mounting on Robolux valves Type 203 Type 885 Type 88 can be combined with Compact stainless steel design Contactless valve position registration Coloured illuminated
3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics
3/2-, 5/2-5/3-way Solenoid Valves for process pneumatics Type 6518 stard High flow-rate capacity Reduced power consumption Single or manifold mounting stard Type 6518/6519 can be combined with... Stard-,
Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv)
Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv) Order code Series and function 1) Plug socket see page 5.042. MN-06-310-HN-442 Standard coil 1) 441 = 12 V DC, 4.2 W 442 = 24 V DC,
SEISMIC VELOCITY TRANSDUCER T1-40
SEISMIC VELOCITY TRANSDUCER T1-40 Measurement of Omnidirectional Absolute Vibrations Certified according to ATEX 94/9/CE directive OPERATION Transducer T1-40 serves for seismic measurement of the absolute
2.12. page 223 2.12. Products for Explosion hazardous Environment
2.12 page 223 2.12 Products for Explosion hazardous Environment Non-electric valves for explosion 2.12.1 page 224 hazardous environment The following manually and mechanically actuated valves are available
S GATE KNIFE GATE VALVE WITH PNEUMATIC ACTUATOR
MAIN FEATURES The pneumatic S GATE knife gate valve is intended for the automatic shut off of pipes of the heavy fluids like slurries and powders. The main fields of application are the water treatment,
Variable Area Flowmeters
www.swagelok.com Variable Area Flowmeters G Series and M Series Glass and metal (armored) tube models, including miniature armored model Highly accurate measurement with individually calibrated scales
How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)
transmitter (2 wire) / switch for continuous or On/Off Control Indication, monitoring, transmitting and continuous or On/Off control in one device Output signal 4...20 ma, 2-wire for continuous control
97300 NAMUR series, 3/2 & 5/2 Indirect solenoid actuated spool valve
9700 NAMUR series, / & / > > Port size: G/, / NPT, NAMUR Interface > > Crossover-free switching > > Main application: Single and double acting actuators > > / way valve usable as / way valve > > Manual
Floodlight Range Installation Guide
SPARTAN Floodlight Range Installation Guide CML13ATEX3007 IEC Ex CML14.0001 This installation guide provides instructions for installing the Infra-Red and White-Light SPARTAN SPX series of explosion protected
Variable V Area Flowmeter Rotameter The Original
Variable V Area Flowmeter Rotameter The Original 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com precise measurement of liquids
INDUSTRIAL CONTROL INSTRUMENTS FOR PROCESS AUTOMATION TOR REED SWITCH
INSTRUCTION MANUAL _ LEVEL SWITCH TOR REED SWITCH Type A B PC PP PF Magnetic level switch. Top mount directly in the tank. Up to 6 action thresholds. DESCRIPTION Level switch formed by: Housing (1) with
Technical Data. Dimensions
0102 Model Number Features Comfort series 5 mm flush Usable up to SIL 2 acc. to IEC 61508 Accessories BF 18 Mounting flange, 18 mm EXG-18 Quick mounting bracket with dead stop Technical Data specifications
3/2, 5/2, 5/2 bistable and 5/3 way pneumatic solenoid valve
3/2, 5/2, 5/2 bistable and 5/3 way pneumatic solenoid valve Type 6518 Type 6519 Type 6518/6519 can be combined with... Single or block mounting Suitable for outdoor and chemical atmospheres Suitable for
Technical Data. Dimensions
0102 Model Number Features 15 mm quasi flush Usable up to SIL2 acc. to IEC 61508 Accessories BF 30 Mounting flange, 30 mm V1-G-N-2M-PUR Female cordset, M12, 2-pin, NAMUR, PUR cable V1-W-N-2M-PUR Female
How To Use A Corona Mdi 110
CORONA MDI 110 APPLICATION Domestic water meter FEATURES 4 Modular multi-jet domestic meter with inductive scanning (without magnetic influence) 4 System capability, with standard applicable pulse output
System 6000 Electropneumatic Converter for Direct Current Signals Type 6116 i/p Converter
System 6000 Electropneumatic Converter for Direct Current Signals Type 6116 i/p Converter Application Used to convert a direct-current input signal into a pneumatic output signal for measuring and control
Level Switch LBFS. Technical Data. ATEX data Internal inductivity Li < 10 μh Internal capacity Ci < 43 nf Barrier data. Sensor
Special Features Wetted parts in stainless steel and PEEK Compact design Precise switching point with no requirement for calibration Process temperature 0... 5 C Measures media with DKvalues >.5 (DK =
4 Posiflow Proportional Solenoid Valves
4 Posiflow Solenoid Brass or Stainless Steel Bodies 1/4" to 1/2" NPT 2/2 Features Flow rates adjustable between 0% and 100% of rating Flow rate can also be regulated by a range of electrical inputs (sensors,
Magnetic field sensor for pneumatic cylinders BIM-INT-Y1X-H1141
ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 as per IEC 61508 Rectangular, height 6mm Plastic, PA12 Magnetic-inductive sensor DC 2-wire, nom. 8.2 VDC Output acc. to DIN EN 60947-5-6
Cable Plug acc. to DIN EN 175301-803, Form A
Cable Plug acc. to DIN EN 175301-803, Form A Complete program Contact form 18 mm Also available with LED indicator Optional 4-pin version for pressure switch or impulse valves respectively Versions with
www.kem-kueppers.com [email protected] Certified according to DIN EN ISO 9001 Technical Datasheet TRICOR Series Mass Flow Meters
www.kem-kueppers.com [email protected] Certified according to DIN EN ISO 9001 Technical Datasheet TRICOR Series Mass Flow Meters Description The Tricor Mass Flow Meters measure simultaneously mass
ELECTROMAGNETIC FLOWMETER COMPACT
R ELECTROMAGNETIC FLOWMETER COMPACT For conductivit Liquids MIK frequency-, switching-, analog otput digital plug on display Range from liquids, acids and caustic solutions:0.01-0.5...35-7000l/min Accuracy:
Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate
1 919 1919P01 1919P03 QBM65/C, QBM75-1U/C Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate QBM751-1/C QBM65/C QBM75/C Highly accurate measurements with calibration
Digital display DA 48
Loop powered plug-in LCD display No auxiliary energy source needed Scale freely adjustable on site Can be turned to any position Suitable for any 0 ma transmitter with EN 175301-803A connector Digital
4/2-Way Pneumatic Solenoid Valve
4/2-Way Pneumatic Solenoid Valve Robust servo assisted piston valve Service friendly manual override Single or block assembly Explosion-proof versions Type 5413 cam be combined with Type 2508 Cable plug
type V46, solenoid or pneumatic operated
SPECIFICATION general type of construction spool valve operator solenoid or pneumatic operated or by manual override. Manual override is equipped with a monostable function (push) and a bistable function
Turbine Flow Sensor Series VTR
Turbine Flow Sensor Series VTR SIKA Turbine Flow Sensor Series VTR Extra robust, impressively precise SIKA s VTR turbine flow sensor allows you to determine precisely, dependably and easily the flow rates
3/2, 5/2, 5/2 bistable and 5/3 way pneumatic solenoid valve
3/2, 5/2, 5/2 bistable and 5/3 way pneumatic solenoid valve Type 6518 Type 6519 Type 6518/6519 can be combined with... Single or block mounting Suitable for outdoor and chemical atmospheres Suitable for
Software and Display instruments
Software and Display instruments 272 Overview Software and Display instruments 276 VEGA Inventory System 278 DTM Collection und PACTware 279 VEGACONNECT 280 PLICSCOM, PLICSLED 282 VEGADIS 81, 82, 176 271
8146/5 Series Breaker Panelboards
8146/5 Series Breaker Panelboards DISTRIBUTION BREAKER PANELBOARDS FOR HAZARDOUS & CORROSIVE ENVIRONMENTS Breaker Panels Features: Wide variety of Flameproof branch circuit breakers for Zone 1 & Division
OPTIMASS 6000 Technical Datasheet
OPTIMASS 6000 Technical Datasheet Sensor for mass flow The high performance meter for process industries Cryogenic, high temperature and high pressure options Supreme liquid and gas performance with CT
Technical Information RIA14
TI00143R/09/EN/04.14 71256618 Products Solutions Services Technical Information RIA14 Loop powered field indicator With explosion proof enclosure (according to Ex d) Application Oil & gas Petrochemical
Thermometer in stainless steel with capillary and switch contacts
Design Type Case diameter Thermometer in and switch contacts 7308 = back flange for wall mounting 7312 = front flange for panel mounting 7310 = mounting bracket for wall mounting Dim 100 mm or 160 mm Accuracy
www.kem-kueppers.com [email protected] Certified according to DIN EN ISO 9001 Technical Datasheet KVO Series Vortex Flow Meter
www.kem-kueppers.com Certified according to DIN EN ISO 9001 Technical Datasheet KVO Series Vortex Flow Meter Description The KVO Vortex flow meters utilize two primary sensing elements a vortex shedding
Series DFMT Digital Paddlewheel Flowmeter
Series DFMT Digital Paddlewheel Flowmeter Bulletin F-DFMT Specifications - Installation Operating Instructions -/8 [00] -/ [8] -/8 [00] A The Series DFMT Digital Paddlewheel Flow Transmitter provides instantaneous
Temperature sensor with integrated transmitter for industrial applications, MBT 3560
Temperature sensor with integrated transmitter for industrial applications, MBT 3560 Technical brochure Features Designed for use in harsh industrial enviroments where reliable, robust and accurate equipment
Isolating Barriers for our sensors A5S1 in Ex-areas Series D461
D46 Isolating Barriers for our sensors A5S1 in Ex-areas Series KEY FEATURES ATEX / IECEx certified, also approval for UL / CSA and EAC (Russia, Kazakhstan and Belarus Customs Union) Protection grade Ex
OPTIMASS 1400 Technical Datasheet
OPTIMASS 1400 Technical Datasheet Sensor for mass flow First choice for universal applications Best price-performance ratio A wide range of options available with no restrictions The documentation is only
BM SERIES WAVE COMPACT 6.3 GHZ CW SERIES PULSE RADAR LEVEL INSTRUMENTS (6.3 GHz)
CW SERIES PULSE RADAR LEVEL INSTRUMENTS (6.3 GHz) DESCRIPTION The Radar Level Meters of BM COMPACT WAVE 6.3 GHz series are excellent devices for no contact level measurement. The microwave impulses, emitted
Art.S001-S002 SOLAR MODULE WITH DELIVERY AND RETURN CONNECTIONS
Art.S001-S002 SOLAR MODULE WITH DELIVERY AND RETURN CONNECTIONS Technical Information sheet 0001/07/Rev01 ENG FUNCTION Series S001 and S002 circulation units are applied to the primary circuit of solar
Terminal Boxes in Glass Fiber Reinforced Polyester (GRP)
Features Variants options Glass fiber reinforced polyester (GRP) enclosures Suitable for installation in Zones 0, 1, 2, 21 and 22 Certified Ex e, Ex ia and Ex tb 16 enclosure size options Various terminal
Technical Data. General specifications Switching element function Rated operating distance s n 5 mm
0102 Model Number Features 5 mm non-flush Usable up to SIL 2 acc. to IEC 61508 Technical Data specifications Switching element function NAMUR, NC Rated operating distance s n 5 mm Installation non-flush
EX-TECH SAS CP/PB 150 EXPLOSIONPROOF MANUAL CALL POINT/ PUSH BOTTON TECHNICAL MANUAL
PRODUCT NAME: CP/PB -150- EXPLOSION-PROOF-MANUAL CALL POINT/ PUSH BOTTON DOC NO.: EX-TECH SAS-12-CP-PB150-TM REV01 EXPLOSION-PROOF MANUAL CALL POINT/ PUSH BOTTON II 2GD EPL Gb, Db Ex d IIC T6, IP66 Ex
FLOW SYSTEM flow measurement system in open channels and non-pressurized pipes
FLOW SYSTEM flow measurement system in open channels and non-pressurized pipes The flow measurement in open channels is based on the measurement of the increase in height due to the insertion of a suitable
Solenoid Valve Island Type 3965
Solenoid Valve Island Type 365 for the control of pneumatic actuators General The Type 365 Solenoid Valve Island is a compact solution for the centralized control of pneumatic actuators in chemical and
Linear Luminaire with LED Series EXLUX 6402/2
> Latest LED technology with a high luminous efficacy and a long service life > As pendant light fitting or side entry lamp > Central locking > All-pole disconnection by means of an N/C switch when the
Electronic pressure switch with display Model PSD-30, standard version Model PSD-31, with flush diaphragm
Electronic pressure measurement Electronic pressure switch with display Model PSD-30, standard version Model PSD-31, with flush diaphragm WIKA data sheet PE 81.67 Applications Machine tools Hydraulics
Ammeter / Voltmeter Series 8402, 8403, 8405, 8404
/, 8403, 8405, 8404 > Fast comparison of measured with set values > s available, 8403 and 8402 www.stahl.de, 8403, 8405, 8404 10073E00 The ammeters and voltmeters from R. STAHL are explosion protected,
B-Series Temperature Switches
FEATURES B-Series switches have proven reliable in such harsh environments as: Offshore oil rigs Chemical and petrochemical plants Pulp and paper mills Steel mills Power plants Water and sewage-treatment
Worcester DS/DM Series UltraSwitch Switch box
Worcester DS/DM Series UltraSwitch Switch box Features DS/DM Series Ultraswitch Description The DS/DM Series UltraSwich from Flowserve Worcester provides cost efficient, accurate and reliable position
Ferrostat Speed Sensor Series DSF Explosion Proof Versions EEx
Ferrostat Speed Sensor Series DSF Explosion Proof Versions EEx DSF..10.**.HV Ex ATEX Operating Instructions 374E-64368 Valid from lot nr. 0103 General Function Use in potentially explosive environment
Hydraulic Control Solutions
Hydraulic Control Solutions Vexve s Hydrox hydraulic control solutions are suitable for even the most challenging installation sites and conditions. Specifically designed for district heating and district
Labkotec SET. Labkotec separator alarm system protecting our environment. Measure your success
Labkotec SET Labkotec separator alarm system protecting our environment Designed to comply EN 858-1&2 and PPG3 norms Warns of excessive levels of oil, sludge & liquids Prevents pollution incidents Fail-safe
Fluxi 2000/TZ Turbine Gas Meter
Gas Fluxi 2000/TZ Turbine Gas Meter Turbine gas meters are flow meters. The flow of gas turns a turbine wheel, and thus, the rotating speed of the turbine is proportional to the linear speed of the gas.
Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points
Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points Features SELV Compliant No Detection Passive Injector Gigabit Compatible Full Protection
Mobrey Ultrasonic. MSP900SH Level and MSP900FH Flow Transmitters. Product Data Sheet February 2015 IP2032, Rev BA
Mobrey Ultrasonic MSP900SH Level and MSP900FH Flow Transmitters Product Data Sheet February 2015 IP2032, Rev BA Non-contacting measurement with no moving parts Fast and simple to install and configure
3/2-way Solenoid Valve, direct-acting, NC or NO
3/2-way Solenoid Valve, direct-acting, NC or NO Electrical connection cable plug, Form A With or without manual override as standard Threaded port and sub-base s Impulse optional Type 6014 can be combined
RUBBER SLEEVE KNIFE GATE VALVE
RUBBER SLEEVE KNIFE GATE VALVE The model knife gate is a wafer valve designed for a wide range of industrial applications. The double-seated design provides bi-directional shut off. The design of the valve
Linear Luminaire for Fluorescent Lamps Series EXLUX 6001
> As wall, ceiling and pendant light fitting or side entry lamp > Version with 2 lamps: 18 W, 36 W and 58 W > Central locking > All-pole disconnection by means of an N/C switch when the lamp is opened
Relative pressure transmitter type 520
Relative pressure transmitter type 520 Pressure range -1... 9 bar / 0... 2.5 1000 bar The compact type 520 pressure transmitter is based upon the Huba Control developed thick film technology where the
T U R B I N E G A S M E T E R
TURBINE GAS METER TURBINE GAS METER CGT 1 2 3 4 5 6 7 Design and function page 2 General technical data page 3 Measurement outputs page 4 Dimensions and weights page 5 Performance page 7 Pressure loss
Pressure monitoring equipment for oil-sf 6. bushings, type GOEK
Pressure monitoring equipment for oil-sf 6 bushings, type GOEK Installation and maintenance guide 5693 827-6 en, Rev. 3, 2002-01-30 This document must not be copied without our written permission, and
Technical Data. General specifications Switching element function Rated operating distance s n 15 mm
0102 Model Number Features Comfort series 15 mm flush Accessories MHW 01 Modular mounting bracket MH 04-2057B Mounting aid for VariKont and +U1+ Technical Data General specifications Switching element
Throughbeam photoelectric sensors. Dimensioned drawing. Electrical connection
Specifications and description Leuze electronic LS 78 Throughbeam photoelectric sensors Dimensioned drawing 180m 10-30 V DC! Voltage range from 12 30VDC with NPN, PNP and/or relay outputs! Light/dark switching!
Single sub-base valve
solenoid valves Mini-valves 10 mm Electrical connection... Mounting... Port sizes... Rated temperature... Fluid... Working pressure... Nominal flow... Pneumatic connections Voltage... Power... NC poppet
Operating Instructions for Plastic Flow Meter. Model: KSK
Operating Instructions for Plastic Flow Meter Model: KSK 1. Contents 1. Contents... 2 2. Note... 3 3. Instrument Inspection... 3 4. Regulation Use... 3 5. Operating Principle... 4 6. Mechanical Connection...
Power Supply and Indicator Unit Type 5024-1. Fig. 1 Type 5024-1. Mounting and Operating Instructions EB 9539 EN
Power Supply and Indicator Unit Type 5024-1 Fig. 1 Type 5024-1 Mounting and Operating Instructions EB 9539 EN Edition October 2003 Application 1 Application The Type 5024-1 Power Supply and Indicator Unit
Messko. Messko. MTraB - Maintenance Free Dehydrating Breather Ordering specifications 686 - XX - XX - XXX - XX
Ordering specifications MTraB -Series Maintenance Free Dehydrating Breather Part no.: 686 - - - - Form your part number by selecting the individual parameters: For example: 686-10--103- Part no.: Parameter
Instruction Manual Differential Pressure Transmitter
DE28 Instruction Manual Differential Pressure Transmitter Table of Contents 1. Safety Instructions 2. Intended Applications 3. Product Description and Functions 4. Installation 5. Commissioning 6. Maintenance
Retractable Housings. InTrac 781 / 784 Versatile and Rugged For the Toughest Process Conditions INGOLD
INGOLD Leading Process Analytics Retractable Housings InTrac Retractable Sensor Housings for Harsh Applications Wide Range of Options Intelligent Sensor Locking System Highly Efficient Sensor Cleaning
Technical Data. General specifications Switching element function Rated operating distance s n 5 mm
0102 Model Number Features 5 mm flush Usable up to SIL 2 acc. to IEC 61508 Accessories EXG-18 Quick mounting bracket with dead stop BF 18 Mounting flange, 18 mm Technical Data specifications Switching
S-series Mass Connection Solutions
DeltaV Distributed Control System Product Data Sheet March 2015 S-series Mass Connection Solutions Fast, easy and error-free cabinet wiring Modular design, improves reliability Lowers overall termination
Regards from the Team at Rheology Solutions.
Rheology Solutions is the sole Australian distributor of this product range and we welcome the opportunity of discussing your application requirements. We hope the information you are seeking is contained
Conductive Level Switch FK 2 Technical Data:
Level switch for conductive liquids Optional electrode length adjustment Hygienic installation in accordance with EHEDG Wetted parts compatible with FDA requirements Potted electronic Not influenced by
R4D0-FB-IA* FieldBarrier. Features. Assembly. Function. Connection IN + - S OUT ... ... Spur 2. Spur 1. Zone 1. Zone 0
FieldBarrier Features Assembly 8... 12 outputs Ex ia IIC, FISCO and Entity Advanced fault isolation and diagnostics at the spur FieldBarrier in Zone 1/Div. 2 Instruments in Zone 0...1/Div. 1 For FOUNDATION
www.kem-kueppers.com [email protected] Certified according to DIN EN ISO 9001 Technical Datasheet C-Flow Coriolis Mass Flow Meter
www.kem-kueppers.com [email protected] Certified according to DIN EN ISO 9001 Technical Datasheet C-Flow Coriolis Mass Flow Meter Description The coriolis mass flow meters measure simultaneously mass
NIVOCONT CONDUCTIVE LEVEL SWITCHES LEVEL SWITCHES
NIVOCONT CONDUCTIVE LEVEL SWITCHES O U R P R O F E S S I O N I S Y O U R L E V E L LEVEL SWITCHES APPLICATION Level switches, based on the conductivity principle, can be applied to liquids with conductivity
Threaded Resistance Thermometers Model TR10-D, Miniature Design
Electrical Temperature Measurement Threaded Resistance Thermometers Model TR10-D, Miniature Design WIKA Data Sheet TE 60.04 Applications Machine building, plant and tank construction Power transmission
Technical Specifications
ZCAM3 HAZARDOUS AREA THERMAL IMAGING CAMERAS DS-003 Issue 01 ZIZCAM Ltd are a UK based manufacturer of CCTV Cameras for use in the Hazardous Oil, Gas and Petrochemical industries. Consequently our products
Ammeter / Voltmeter Series 8402, 8403, 8405, 8404
/, 8403, 8405, 8404 > Fast comparison of measured with set values > s available, 8403 and 8402 www.stahl.de, 8403, 8405, 8404 10073E00 The ammeters and voltmeters from R. STAHL are explosion protected,
BUTTERFLY VALVES API 609 WAFER LUG U-SECTION BODY STYLE DIAPHRAGM VALVES EN13397:2000 WEIR BODY STYLE
CATALOGUE 2012 - PART 2 WATER TREATMENT BUTTERFLY VALVES API 609 WAFER LUG U-SECTION BODY STYLE DIAPHRAGM VALVES EN13397:2000 WEIR BODY STYLE DIAPHRAGM VALVES EN13397:2000 STRAIGHT- THROUGH BODY STYLE
T1-40 T1-40BF T1-40V T1-38 T1-38BF T1-38V
Transducers T1-40 T1-40BF T1-40V T1-38 T1-38BF T1-38V Velocity transducers B A L A N C I N G M A C H I N E S B A L A N C I N G M A C H I N E S Principle of operation A voltage proportional to the velocity
Technical Data. General specifications Switching element function Rated operating distance s n 4 mm
0102 Model Number Features 4 mm non-flush Usable up to SIL 3 acc. to IEC 61508 Application Danger! In safety-related applications the sensor must be operated with a qualified fail safe interface from Pepperl+Fuchs,
Assisted lift operated 2/2-way solenoid valves Type EV250B
MAKING MODERN LIVING POSSIBLE Data sheet Assisted lift operated 2/2-way solenoid valves Type EV250B EV250B with assisted lift can operate from zero and up to 10 bar differential pressure. This 2/2-way
AT500 Magnetostrictive Level Transmitter. Compact magnetostrictive liquid level transmitter for direct insertion K-TEK Products
Data sheet DS/AT500-EN Rev. M AT500 Magnetostrictive Level Transmitter Compact magnetostrictive liquid level transmitter for direct insertion K-TEK Products Features Mounts from Top of Tank High Resolution
Liquid Level Limit Switch liquiphant T FTL 20
Technical Information TI 64F/4/ae Liquid Level Limit Switch liquiphant T FTL 0 Level limit switch for liquids Applications The Liquiphant T FTL 0 is a level limit switch for virtually any kind of fluid