Smarter Data Centers. Integrated Data Center Service Management



Similar documents
CarbonDecisions. The green data centre. Why becoming a green data centre makes good business sense

Enterprise Data Centre

Data Center & IT Infrastructure Optimization. Trends & Best Practices. Mickey Iqbal - IBM Distinguished Engineer. IBM Global Technology Services

Green ICT: Consistent Actions to Reduce Energy Consumption

Metrics for Data Centre Efficiency

Data Center Energy Use, Metrics and Rating Systems

Sanjeev Gupta Product Manager Site and Facilities Services

DC Pro Assessment Tools. November 14, 2010

How To Manage Energy At An Energy Efficient Cost

Energy Management in a Cloud Computing Environment

General Recommendations for a Federal Data Center Energy Management Dashboard Display

CREATING & MANAGING A DYNAMIC INFRASTRUCTURE

Identifying Energy Saving Opportunities in the Data Center

Benchmarking results from Indian data centers

1. Data Centre Environment Why focus on Data Centres? Hitachi Eco-Friendly Data Centre Solutions

AbSTRACT INTRODUCTION background

Guideline for Water and Energy Considerations During Federal Data Center Consolidations

Managing Power Usage with Energy Efficiency Metrics: The Available Me...

THE GREEN GRID DATA CENTER POWER EFFICIENCY METRICS: PUE AND DCiE

GHG Protocol Product Life Cycle Accounting and Reporting Standard ICT Sector Guidance. Chapter 8: 8 Guide for assessing GHG emissions of Data Centers

Datacenter Efficiency

abstract about the GREEn GRiD

Living Green in the Data Center. Dominick Regina Associate Director, Infrastructure Services

DECREASING DATACENTER AND OTHER IT ENERGY

Measuring Power in your Data Center: The Roadmap to your PUE and Carbon Footprint

GREEN GRID DATA CENTER POWER EFFICIENCY METRICS: PUE AND DCIE

Convergence of Complexity

Data Centre and ICT Energy Metrics - The View from Australia

Managing the New Enterprise Data Centre

DataCenter 2020: first results for energy-optimization at existing data centers

Uptime Institute Network Top 10 Data Center Technology Priorities for Vice President, Global Director

Energy Efficient High-tech Buildings

IBM and Dynamic Infrastructure. Doug Neilson, IBM Systems Group May 2009

Heat Recovery from Data Centres Conference Designing Energy Efficient Data Centres

Wireless Sensor Technology for Data Centers

Green Computing: Datacentres

Energy management White paper. Greening the data center with IBM Tivoli software: an integrated approach to managing energy.

Case Study: Opportunities to Improve Energy Efficiency in Three Federal Data Centers

Reducing Data Center Energy Consumption

Data Center Infrastructure Management: ERP for the Data Center Manager

Green Computing: Datacentres

Understanding Power Usage Effectiveness (PUE) & Data Center Infrastructure Management (DCIM)

Re Engineering to a "Green" Data Center, with Measurable ROI

Holistic, Energy Efficient Datacentre Cardiff Going Green Can Save Money

Data Centre Cooling Technologies. Jon Pettitt, EMEA DataCenter Business Development Manager

AIA Provider: Colorado Green Building Guild Provider Number: Speaker: Geoff Overland

Harmonizing Global Metrics for Data Center Energy Efficiency

Case Study: Innovative Energy Efficiency Approaches in NOAA s Environmental Security Computing Center in Fairmont, West Virginia

Recommendations for Measuring and Reporting Overall Data Center Efficiency

7 Best Practices for Increasing Efficiency, Availability and Capacity. XXXX XXXXXXXX Liebert North America

Electrical Systems. <Presenter>

Data Centers: Definitions, Concepts and Concerns

Questions to be responded to by the firm submitting the application. Why do you think this project should receive an award? How does it demonstrate:

Sustain and Gain Because Going Green Makes Good Business Sense IBM Corporation IT Optimization 6-Dec-07 1

Tulevaisuuden datakeskukset Ympäristö- ja energianäkökulmia

Measuring Energy Efficiency in a Data Center

DOE Data Center Energy Efficiency Program

Optimizing IT costs with Cloud. Tarmo Tikerpäe Datacenter SSP Microsoft Corporation

Office of the Government Chief Information Officer. Green Data Centre Practices

DATA CENTER ASSESSMENT SERVICES

StruxureWare. How to reconcile efficiency and availability in a virtualized data center. for data centers

Energy Efficiency Monitoring in Data Centers: Case Study at International Hellenic University. George Koutitas, Prof. L. Tassiulas, Prof. I.

Solve your IT energy crisis WITH An energy SMArT SoluTIon FroM Dell

Introduction to IT Infrastructure Components and Their Operation. Balázs Kuti

Specialty Environment Design Mission Critical Facilities

FEAR Model - Review Cell Module Block

Datacenter Power Delivery Architectures : Efficiency and Annual Operating Costs

How to Maximize Data Center Efficiencies with Rack Level Power Distribution and Monitoring

Minimizing Energy-Related Costs In Data Centers and Network Operations Centers

Improving Data Center (Server Room) Energy Efficiency at Caltech. Daniel Alvarez SURF Project 2008 August 19, 2008

IT Cost Savings Audit. Information Technology Report. Prepared for XYZ Inc. November 2009

Data Center Infrastructure Management: How to Optimize Data Center Operations

Bridging the gap for optimized efficiencies and smarter decisions

A Market Transformation Programme for Improving Energy Efficiency in Data Centres

Server Technology, Inc.

Implementing Energy Efficient Data Centers

Recommendations for Measuring and Reporting Overall Data Center Efficiency

Power Usage Effectiveness (PUE) & Data Center Infrastructure Efficiency (DCiE) Progress

The Trellis Dynamic Infrastructure Optimization Platform

Global Green Data Center Best Practices In Action

Implement Data Center Energy Saving Management with Green Data Center Environment and Energy Performance Indicators

Increasing Data Center Efficiency through Metering and Monitoring Power Usage

How green is your data center?

Revitalising your Data Centre by Injecting Cloud Computing Attributes. Ricardo Lamas, Cloud Computing Consulting Architect IBM Australia

BCS Intermediate Certificate in Energy and Cost Management in the Data Centre Syllabus

Guidance for Calculation of Efficiency (PUE) in Data Centers

Global Headquarters: 5 Speen Street Framingham, MA USA P F

Server Technology, Inc.

How To Design A Data Center

Understanding the Promise of (DCIM)

Guide to Cloud Computing INFORMATION

Initial Steps in Capacity Management for the Green Datacenter

Data Center Industry Leaders Reach Agreement on Guiding Principles for Energy Efficiency Metrics

Data Centers That Deliver Better Results. Bring Your Building Together

An Energy-aware Multi-start Local Search Metaheuristic for Scheduling VMs within the OpenNebula Cloud Distribution

Managing Data Centre Heat Issues

Cooling Capacity Factor (CCF) Reveals Stranded Capacity and Data Center Cost Savings

San Francisco Chapter. Deborah Grove, Principal Grove-Associates

Intel Service Assurance Administrator. Product Overview

Energy Management Services

Transcription:

Smarter Data Centers Integrated Data Center Service Management

Approx. 3.500 ton CO² is generated by: Diesel Car-6l /100 km 20.000 km Airplane 5 * Brussels-Barcelona Server, 1.5 A, 24*7*365*3.000 Kwhr

Benchmarks Power Usage Effectiveness PUE Power Usage Effectiveness = Total Facility Power/IT Equipment Power The Total Facility Power is defined as the power measured at the utility meter and is power dedicated solely to the data center IT Equipment Power includes servers, storage, and network equipment, plus equipment such as KVM switches, monitors, and workstations/laptops used to monitor or otherwise control the data center Most energy efficient Objective Current Least energy efficient 1.0 1.5 2.0 2.5 3.0 (1) Standard supported by Green Grid, originally published by Lawrence Berkley National Laboratory, 2003

Extend the life with improved data center energy efficiency Address both the IT and physical infrastructure uses of energyto Start % of total data center electricity use 30 25 20 15 10 5 Cooling systems Electrical and building systems Electrical and Building Systems 0 Information technology Chiller/ cooling tower Humidifier Computer room airconditioner Power distribution unit Uninterruptible power supply (UPS) Switch/ gen Lighting Power use Optimize IT Infrastructure Active Energy Management Chart and data source: American Power Conversion Corporation (APC) white paper, Implementing Energy Efficient Data Centers, #114, by Neil Rasmussen, 2006. Optimize Data Center Infrastructure

Design new infrastructure to be responsive to change Data center capital costs 60% costs from energy related components Data center operating costs 75% costs from energy use Mechanical 20% Fees 24% Instrumentation & Controls 4% Power 36% Fit out costs 9% Shell 7% Source: IBM Estimates

Energy efficiency provides an opportunity to address operational efficiency, flexibility, and resilience Extend the life of an existing data center infrastructure Double IT capacity Or Reduce operational Expenses by 50% Rationalize the data center infrastructure across the company Improve operational Efficiencies while Reducing operational Expenses by 50% Design new infrastructure to be responsive to change Pay as you grow by Deferring 40 50% of Capital and operational costs

Where are all those kw consumed? 100 PUE 1.65 Data Center Server Hardware 80 60 40 20 0 Typical Utilization Mainframe 80 90% Unix 10 20% Wintel 5 12% Server Loads HVAC, UPS 40% IT power 60% AC/DC losses; 25% DC/DC losses; 10% Fans; 9% Processor 30% Idle; 80% Used Resource 20% = 3,6% of total Standby; 2% Drives; 6% PCI; 3% Planar; 4% Memory; 11% Need one more W of compute energy? 27 W data center X1,7 16 W equiv IT power x3 5 W equiv processor x5 +1 W equiv. used ressource Sites & Facilities Systems Design 5.6W x1.7 3.3W x3 1.1W x1.1 @90%!

Who is responsible for energy efficiency in data centers? IBM recommends that one person should be named as being responsible for energy efficiency within data centers One person One (virtual) organisation One budget One process One set of guidelines and best practices One set of tools To manage energy efficiency you need to measure and monitor energy consumption across the Data Center ref European Data Center Code of Conduct

How is a Data Center Managed today IT Facilities Data Center

How should a Data Center be managed End to end Energy, Quality, Service and Risk Management Data Center Integrated Governance, Service & Process Mgt + Tools

Data Center Integrated Monitoring and Management Services (DCIMMS) Simulation Virtualize Data Center Management Collect & Measure Control Manage

Integrated Management approach Define and agree a common strategy and focus related to Data Center services? Determine gap matrix between IT and Facilities processes Define clear ownership for all major elements ie energy Start managing and monitoring energy across the Data Center Develop Data Center SLA s and KPI s? Prioritize process improvements to reduce Data Center risks and cost and improve quality of service

Data Center Service Management: Delivering Quality and Cost effective Services Visibility: See your Business DC Service Management Control: Manage your Business DC Best Practices, Methodologies & Services DC Service Management Platform Automation: Improve your Business

Establish an open-based platform Data Center Service Management Data Center Best Practices, Methodologies, and Services Data Center Service Management Platform Do you need to manage all your key processes from a single interface? Does the health & performance of your applications support your business? Do you need to manage all of your data, information and storage resources? Are your people, applications and data secure? Are you sure? Do you need an energy-efficient datacenter? How will you manage SOA? Can you visualize & control of all your assets? Do you want your asset lifecycle automated? Can you deliver effective network services? Is QoS important? Visibility Control Automation

Perspective on the data center monitoring and management market The current market is a fragmented one, with no standards. There are a myriad of suppliers and solutions, but no single solution that bridges all user pain points. Lacking visibility Understanding need to manage Integrated IT and Facilities ops Clients lack true understanding of data center operational issues: IT/Facilities Room for growth Clients Efficiency seeking visibility to data: Manual processes Estimated usages Niche tools Facilities and to fully optimize business applications Integration of IT and operations Time (years) Gartner Group predicts 60x growth in this space through 2014

Right-sized facilities for optimized IT Start improving data center efficiency by monitoring asset utilization Optimize utilization to gain power savings and the opportunity to reduce cooling See efficiency results with industry standard energy metrics Overall CPU cycle usage very low Realize 60% of servers can be running at less than 5% utilization Ensure high availability by monitoring temperatures in high density IT areas for compliance Use detailed reports to provide energy savings and carbon reduction for incentives Drill down capability identifies assets with low utilization

Graham Aldridge Benelux Data Centre Expert T +32 2 339 79 62 graham.aldridge@be.ibm.com Thank you