Data Center Site Qualification Program. Executive Summary



Similar documents
Data Center Site Qualification Program. Executive Summary

datacentersites.com Security, Infrastructure Redundancy Tier 3+/Tier 4 Data Center Sites

Subject: County of Los Angeles Data Center Space Requirement

N O W A V A I L A B L E

T5 CHARLOTTE REGION WEST DATA CENTER PARK

Midwest s Premier Carrier Neutral Colocation Data Center Greater Minneapolis St. Paul, Minnesota

Emergency Management Planning Criteria for Nursing Home Facilities (Criteria)

Data Center Site Qualification Program. Detailed Site Prospectus

NURSING HOME STATUE RULE CRITERIA

Emergency Management Planning Criteria For Residential Treatment Facilities

N O W L E A S I N G C H A R L O T T E G A T E W A Y D A T A C E N T E R. Charlotte, North Carolina. Contact Doug Hollidge for more information.

EMERGENCY MANAGEMENT PLANNING CRITERIA FOR AMBULATORY SURGICAL CENTERS

CEMP Criteria for Residential Treatment Facilities

Data Center Site Qualification Program. Detailed Site Prospectus

How To Build A Data Center For Ragingwire

ADULT DAY CARE CENTER

F O R L E A S E F O R S A L E

DATA CENTERS. VAZATA Headquarters: 6900 Dallas Parkway, Suite 800 Plano, TX VAZATA.COM

F O R L E A S E F O R S A L E

CyberFortress Data Center at Innovation Park Infrastructure and Topology Guide. Innovation Park Charlotte. NC DRAFT V0.

Data Center Site Qualification Program. Detailed Site Prospectus

AMBULATORY SURGICAL CENTERS

Emergency Management Planning Criteria for Assisted Living Facilities (State Criteria Form)

9314 JEFFERSON BLVD DALLAS, TEXAS DALLASGLOBAL.COM

Pacnet Hong Kong CloudSpace2 Technical Specifications. Upholding the Principles of Efficiency and Sustainability in Data Center Design

EMERGENCY MANAGEMENT PLANNING CRITERIA FOR HOSPITALS

A Sustainable, Master-Planned Data Center Park.

Colocation Buyer s Guide and Checklist. A Playbook for Technology Managers

Prepared by Kory Menken & Andrew Finzen 10/26/14. North Sioux City Economic Development Corporation Flynn Business Park

EMERGENCY MANAGEMENT PLANNING & COMPLIANCE REVIEW CRITERIA FOR NURSING HOMES [FL RULE CHAPTER 59A F.A.C]

*****IMPORTANT SUBMITTAL INFORMATION*****

POWERING A CONNECTED ASIA. Pacnet Hong Kong CloudSpace1 Technical Specifications. Asia s Pioneering Facility with Direct Subsea Cable Access

100 Locust Avenue, Berkeley Heights, New Jersey P R O P E R T Y O F F E R I N G

CleveLAND Cl. CleveL. Cleve. CleveLAND LAND. ANDCleveLANDC AND CUYAHOGA VALLEY INDUSTRIAL CENTER 60+ ACRE SHOVEL-READY SITE

Emergency Management Planning Criteria for Hospital Facilities (State Criteria Form)

Data Center Site Qualification Program. Detailed Site Prospectus

R U T H E R F O R D C O U N T Y, NC D A T A C E N T E R - LAND SITE FOR SALE

Presented by Edward P. Rafter, P.E., CxAP Tier IV Consulting Group

CROSS-REFERENCE FOR COMPREHENSIVE EMERGENCY MANAGEMENT PLAN RESIDENTIAL TREATMENT CENTERS FOR CHILDREN AND ADOLESCENTS

Greenfield Innovation Park

Emergency Management Planning Criteria for Ambulatory Surgical Centers (State Criteria Form)

AMBULATORY SURGICAL CENTERS (Based upon AHCA Form # JUL 94)

VIRGINIASCAN OFFICE BUILDING DATA SHEET

COUNTY OF ALBEMARLE PLANNING STAFF REPORT SUMMARY. Staff: Claudette Grant

HIGHLAND COUNTY OHIO WE RE OPEN FOR BUSINESS

Jacksonville Port Authority: Fire and Rescue Marine Fire Station #40, Jacksonville, Florida

Digital Chicago. 600 south FeDeraL - chicago grand ave - FranKLin ParK 350 east cermak - chicago

House your data in a building constructed for only one express purpose protect the information inside. Twin Cities East Data

Restoration. a brief look at

Geographic Factors for Data Center Site Selection

HOSPITALS STATUTE RULE CRITERIA. Current until changed by State Legislature or AHCA

TRANSPORTATION IN MISHAWAKA

COMMODITIZING THE DATACENTER. Exploring the Impacts of the Shift to Virtualization and Cloud Computing

World s Greenest High Performance Data Center

EMERGENCY MANAGEMENT PLANNING CRITERIA FOR ADULT DAY CARE FACILITIES

Colocation. Scalable Solutions for a Shared IT Infrastructure. Enterprise. Colocation

CHICAGO S PREMIERE DATA CENTER

PUBLIC SCHOOL FACILITIES ELEMENT

100% LEASED - FLEX INDUSTRIAL BUILDING

7QUESTIONSYOUNEEDTOASKBEFORE CHOOSINGACOLOCATIONFACILITY FORYOURBUSINESS

Goal 1 To protect the public health, safety and property from the harmful effects of natural disasters.

SECTION 3 COMMUNITY PROFILE. Geography and the Environment

19 Site Location, Design and Attributes. Site Location, Design and Attributes

LEVEL 3 DATA CENTER SERVICES IN OMAHA, NEBRASKA HIGH AVAILABILITY ENTERPRISE COMPUTING BUSINESS DEMANDS IT. LEVEL 3 DELIVERS IT.

The Data Center Tier Performance Standards and Their Importance to the Owner s Project Requirements

Chapter 7 COMMUNITY FACILITIES and SERVICES PLAN

N O W A V A I L A B L E

Colocation Hosting Primer Making the Business and IT Case for Colocation

NY-1 DATACENTER AT A GLANCE. NY-1 is a Tier III-rated, SAS SSAE16 and HIPAA-certified data center

Marshall V. Davidson Jr. Richard N. Gill

Unique Heavy Infrastructure Site Available Former Alcoa Aluminum Smelter - Badin, North Carolina

Colocation. Scalable Solutions for Shared IT Infrastructure. Enterprise. Colocation

Greater Reading is ready.

August 24, Comments of Grid Assurance LLC on Request for Information on National Power Transformer Reserve, 80 Fed. Reg. 39,422 (July 9, 2015)

Affordable Dwelling Unit Ordinance

Establishment of State s Second Data Center. Business Continuity and Disaster Recovery. North Carolina. Office of Information Technology Services

Data Centre Infrastructure

Application No.: Steve Rush, representing Rocky Mountain Power Rocky Mountain Power Project Location: approximately 1600 N E.

Experience Matters...

INTRODUCTION TO ZONING DISTRICT REGULATIONS

Wholesale Data Center Suites Available Now

Austin Wilson, Agent o c

Transcription:

Data Center Site Qualification Program Executive Summary Nassau Crossing Industrial Park Yulee, FL February 2015

About This Report This feasibility report was prepared in conjunction with Florida Power and Light (FPL s) Data Center Site Qualification Program. The program s objective is the proactive identification and analysis of sites located within FPL's service territory. The site characteristics and attributes are analyzed for companies seeking data center sites in the south east region of the country. The sites offers unique combinations of factors desired by today s mission critical and data center operations. These factors include highly reliable and redundant power and fiber infrastructures, competitive cost structures, and a location insulated from manmade and natural risks. Biggins Lacy Shapiro & Co. (BLS), a location economics and site selection firm, has served as lead consultant for the program, together with its affiliated energy services company, Sugarloaf Associates. Engineering and site evaluation services were provided by Syska Hennessy Group (SHG), a worldwide Mechanical, Electrical, Plumbing and Fire Protection (MEP/FP) design and consulting firm. Syska Hennessy Group also performs specialized design and consulting for Information Technology (IT) systems for data centers and other large facilities. Syska Hennessy Group is ranked #1 in the USA for data center design by Engineering News Record (ENR) magazine. This report was written by SHG using a culmination of their independent analysis of Nassau Crossing Industrial Park (NCIP) 197 acre-site in Yulee, FL (Jacksonville) located within Nassau County and is intended to determine its suitability for a mission critical facility. The review process included an initial site survey and an in-depth review of supporting documents to ascertain the feasibility to support two test model mission critical facilities with 60,000 and 100,000 square feet of computer room "white space." They are designed to current typical industry standards for power usage and an Uptime Institute Tier II redundancy level. Uptime Institute is an unbiased, 3rd party data center research, education, and consulting organization founded in 1993. The Institute provides guidelines for data centers to be qualified according to levels of redundancy, which are detailed later in the report. A Tier II level is basically one where all major equipment has a spare or redundant unit, also known as in N+1 redundancy. This site has been designated a FPL Qualified Data Center Site as part of the FPL Data Center Site Qualification Program (the Program ). To fulfill its obligations pursuant to the Program, Florida Power & Light Company ( FPL ) has provided financial support to independent consultants whose role in the Program is to perform rigorous, independent on-site review of requirements needed to support a major data center. FPL has not performed any such reviews itself, nor does FPL provide any type of guarantee, warranty, promise or covenant, either express or implied, as to the Program and/or any data center. Biggins Lacy Shapiro & Company, a location economics and site selection firm, served as lead consultant for the Program, together with its affiliated energy services company, Sugarloaf Associates, and Syska Hennessy Group, a facilities consulting firm. The FPL Qualified Data Center Site designation is provided without any representations or warranties regarding the suitability of the property for a particular project or with respect to the property s compliance with applicable federal, state or local laws including, without limitation, environmental laws, or regarding the presence of infrastructure, including, without limitation, electrical service, fiber availability, and water service. 2

Executive Summary This report examined the potential for mission critical development at the Nassau Crossing Industrial Park (NCIP) site in Yulee, FL (Jacksonville). The NCIP is part of an industrial park with a total of 197 acres, inclusive of wetlands and utility rights-of-way (ROWs). The area being evaluated has approximately 20-30 acres of undeveloped land at the northwest portion of the site. This land is all considered Uplands and therefore contains no Wetlands areas, as do the land areas on the southern portion of NCIP. There are other areas available within the park. From a location standpoint the site is ideally situated 3 miles from Interstate 95 and 15 miles from Jacksonville International airport. This site is 11 miles inland from the coast and is at an elevation of 40+ above sea level, which eliminates storm surge and provides protection against the most common impacts of hurricanes and tropical storms. The analysis demonstrates good potential for data center development. The site s orientation is favorable for data center development, and it offers strong utility infrastructure. Logistically, the Jacksonville-Yulee area offers an open industrial zoned site with plenty of power and water utility infrastructure which is conducive to data center development. Although the public transportation options are limited, the site at the Nassau Crossing Industrial Park is a short drive from Jacksonville, a major metropolitan area along the east coast of Florida, and has several key aspects that are favorable for mission critical development. The site s location is appropriate for a stand-alone enterprise user or a co-location facility, and the site will physically accommodate either. For purposes of this analysis, the site was designed with 60,000-100,000 square feet of raised floor computer room, also known as white space, and both are presented to demonstrate scalability at this specific site or applicability to other sites. For these data center designs, the overall power required would be 12MW and 20 MW, respectively, in order to serve the cooling, lighting, and other ancillary loads required to operate this type of data center. 3

Graphic 1.1 Map Showing NCIP relationship to major metropolitan areas Graphic 1.2 Map of NCIP Site Location 4

Electrical Substation NCIP State Road A1A Interstate 95 Highway 17 Graphic 1.3 NCIP Site Proximity 5

A. General Information Location Type of Site Size B. Electric Infrastructure Existing Service Voltage FLP Service Voltage Proposed In-Service Date Design Load Capacity Notes SITE ATTRIBUTES NCIP Yulee, Florida Industrial Park 20-30 acres None 23 kv 12 months from signed customer letter of intent Service in excess of 20MW 230/23kV substation is directly across a narrow street, with spare capacity C. Fiber Infrastructure Providers in Vicinity High Bandwidth (Distance from Site) D. Other Utilities Natural Gas Service Natural Gas Provider Water Available Water Capacity Water Provider Sewer Sewer Provider Available Sewer Capacity AT&T 1 mile Adjacent to industrial park, <1 mi to site Florida Public Utilities 12 domestic water nearby in street Capacity is in excess of 300,000 GPD for the site JEA 10 force main nearby in street JEA 300,000 GPD E. Natural Disaster Risk Seismic Rating Very Low (See Chapter 5) Tornado Rating Low (See Chapter 5) Hurricane Rating Moderate (See Chapter 5) F. Man-Made Disaster Risk Low susceptibility to man-made disasters. Neighboring industrial activities Rail Line Accident Potential for additional industrial development near the site Low concern Low concern Moderate concern Table 1.1 Site Attributes 6

LOCATION EVALUATION Nassau Crossing Industrial Park A. Location a. Proximity to Major Highways Favorable b. Proximity to Public Transportation Unfavorable c. Distance to Metropolitan Cities (<40 Miles) Favorable B. Available Utility Resources a. High Voltage Electrical Services Very Favorable b. Water Very Favorable c. Natural Gas Unfavorable d. Fiber Connectivity Mixed C. Site Logistics/Security a. Proximity to Adjoining Buildings/Property Very Favorable b. Ability to Fence/Secure Property Very Favorable c. Susceptibility to Natural Disasters Mixed to Favorable d. Susceptibility to Man-Made Disasters Very Favorable e. Distance from Building Structure to Street Very Favorable f. Distance from Building Structure to Railroads Mixed g. Access to Service Vendors (1 hour response time) Very Favorable h. Access to Fuel Very Favorable i. Weather Favorable j. Air Quality Favorable k. Site Elevation Very Favorable D. Property a. Available Yard Space for Mission Critical Facility Equip. Very Favorable b. Zoning Approvals Very Favorable c. Provisions for Future Expansion Very Favorable E. Area Demographics a. Population Density Very Favorable b. Workforce and Talent Pool Favorable c. Housing Favorable d. Employment and Income Statistics Favorable e. Local Government and Services Favorable f. School District and Higher Education Favorable Very Favorable Favorable Mixed Unfavorable Table 1.2 Location Evaluation The FPL Qualified Data Center Site designation is provided without any representations or warranties regarding the suitability of the property for a particular project or with respect to the property s compliance with applicable federal, state or local laws including, without limitation, environmental laws, or regarding the presence of infrastructure, including, without limitation, electrical service, fiber availability, and water service. 7