BICSI NxtGEN & Global Data Center Standards Update



Similar documents
Data Center Standards Making Progress on Many Fronts. Jonathan Jew J&M Consultants, Inc

Dat Da a t Cen t Cen er t St andar St d andar s d R o R undup o BICSI, TIA, CENELEC CENELE, ISO Steve Kepekci, RCDD

ANSI/TIA-942 Telecommunications Infrastructure Standards for Data Centers

BICSI Data Center Standard. Presented by: Stephen Banks, RCDD CDCDP

So you want to build a data centre? Look what s coming from BICSI! Matt Flowerday Capitoline FZC mflowerday@capitoline.org

Data Centre Cabling. 20 August 2015 Stefan Naude RCDD The SIEMON Company

Telecommunications Infrastructure Standard for Data Centers Tutorial

ANSI/TIA-942 Telecommunications Infrastructure Standard for Data Centers

Opportunities in data centers for the ITS professional

Data Center Cabling Design Trends

Building a Tier 4 Data Center on a Tier 1 Budget

Data Centre Issues supported in TIA-942 : "Telecommunications Infrastructure for Data Centre s"

Data Center Design Considerations

ABOUT ANIXTER UNIVERSITY

Telecommunications Infrastructure Standard for Data Centers ANSI/TIA-942

Planning, Designing and Installing a Pre-Terminated Copper and Optical Cabling System for the Data Center

TIA 569 Standards Update Pathways & Spaces. Ignacio Diaz, RCDD April 25, 2012

How To Make A Data Center More Efficient

BICSI 002 / TIA 942 / Uptime

TIA-942 Data Centre Standards Overview WHITE PAPER

BICSI :Building Industry Consulting Service International

Cabling Standards Update 2014

Industry Standards Activity Overview

TIA Fiber Optics LAN Section (FOLS) LAN Standards, News & Trends Report

How To Properly Maintain A Fiber Optic Infrastructure

TIA-942: Data Center Standards

Gigabit Passive Optical Networks

FIA FIA. Installation Standards e-ready Building Next Generation IT infrastructures. ϕ The Cabling Partnership AGENDA

This presentation to be used in conjunction with:

The Infrastructure of Tomorrow, Available Today. Luca Rozzoni RCDD Business Line Manager TE Connectivity

Physical Infrastructure trends and evolving certification requirements for Datacenters Ravi Doddavaram

Building Telecommunications Infrastructure Requirements

Intelligent Cable Management Systems

Data Center Optimization: Component Choice. Innovative Design. Enabling Infrastructure

Minimum Standards for Data/Voice Infrastructure in New Building Construction

Designing the Data Center

TELECOMMUNICATIONS DISTRIBUTION DESIGN GUIDE DRAFT

Healthcare. Carol Everett Oliver, RCDD, ESS. Berk-Tek, a Nexans Company

Trends and Standards In Cabling Systems

AMP NETCONNECT Data Center Cabling Solutions

Giganet Copper Cabling Training

TIA STANDARD. Telecommunications Infrastructure Standard for Data Centers TIA-942 TELECOMMUNICATIONS INDUSTRY ASSOCIATION

NUIG Campus Network - Structured Cabling System Standards Information s Solutions & Services (ISS)

Structured and Point to Point Network Cabling for Industrial Automation

This 5 days training Course focuses on Best Practice Data Centre Design, Operation and Management leading to BICSI credits.

Zone Distribution in the Data Center

Specifications for Communication Cabling Distribution Systems

DATA CENTER CABLING DESIGN FUNDAMENTALS

What testing is required for PREMISES Fiber Optic Cabling and the standards used

Telecommunications Systems Narrative Page 1 The Engineering Enterprise

Reliable, Consistent, Quality

Enable Networks UFB Services Agreement Service Description for Central Office and POI Co-location Service

Trends and Standards in LAN Cabling Systems Intelligent Buildings

DATA CENTRES UNDERSTANDING THE ISSUES TECHNICAL ARTICLE

Products. Technology. Services. Delivered Globally. ANIXTER IPASSURED SM FOR SECURITY APPLICATIONS

UT Southwestern Medical Center Information Resources Cable Installation Standard

Optical Fiber Data Center Field Testing. ANSI/BICSI Data Center Design and Implementation Best Practices

Cat 5, 6 or 7? Standards. Background. A University Standard for Structured Wiring. Network Points Installed. British Standards.

Make your business EXCEL with technology solutions provided by Excel Communications Worldwide, Inc.

Arista and Leviton Technology in the Data Center

The Telecommunications Closet and Building Services

Network Topologies and Distances

Data Centre Link Survey

DATA CENTER NETWORK INFRASTRUCTURE. Cable and Connectivity for the Most Demanding Networks. BerkTekLevitonTechnologies.com

TCTC Cabling Specifications

Enable Networks UFB Services Agreement Service Description for Central Office and POI Co-location Service

Specifying an IT Cabling System

Data Center Designs and Hospital Operations

Keyword: TIA 942, Tier level, Nuclear Data Center. Introduction

Building a data center. C R Srinivasan Tata Communications

Specifying Optical Fiber for Data Center Applications Tony Irujo Sales Engineer

Data Center. Pre-terminated. Patch Panel System. Cabling Systems Simplified. Patch Panels. 10G + Gigabit. Patch Cords. Plug & Play Installation

Structured Cabling Statement of Work

Data Center Design for 40/100G

hong kong//china data center specifications tel: fax: internet + intellectual property + intelligence

TELECOMMUNICATIONS STRUCTURED CABLING GUIDELINES AND SPECIFICATIONS. University of Chicago IT Services Infrastructure Services October 2011

Obsolete Fiber Technology? Not in my Data Center!

The Need for Low-Loss Multifiber Connectivity

Introductie BICSI & BICSI DataCenter Standaard

99 Washington Street Melrose, MA Phone Toll Free Visit us at

Specifying Optical Fiber for Data Center Applications Tony Irujo Sales Engineer

DESIGN GUIDELINES. Local Area Network

Introduction to Data Centres

SEAGATE SOFTWARE. About Seagate Software. IBDN Success Stories Technology. Currently, Seagate Software has customers in more than 75 countries

Faster Method for Connecting Customers in the Colocation Data Center

Network Design Incorporated

Technology Considerations in a Connected Building Environment

SECTION COMMUNICATIONS OPTICAL FIBER OSP CABLING

Data Centre Design ready for your future

Doc Ref: baselayer.com 2015 BASELAYER TECHNOLOGY, LLC

Transcription:

BICSI NxtGEN & Global Data Center Standards Update Bob Faber, RCDD/NTS Siemon Global Accounts Manager Chair NEMA High Performance Wire & Cable Chair BICSI Standards Committee Vice Chair BICSI TI&M Committee Member TIA TR42 sub-committees Member SIA and NECA

BICSI NxtGEN NOW acquire specialties without RCDD 2 yrs ITS experience required Pass ITS fundamentals exam Pass specialty exam (NTS, OSP, WD, ESS) RCDD is now tougher to acquire 5 yrs ITS experience required Pass ITS fundamentals exam Pass RCDD exam Master RCDD, RCDD or RITP?

Education & Management Experience RITP ITS Core Exam ITS Training Requirements Master RCDD Review Board Master RCDD Application RCDD ITS Core Exam No add l Add l specialty or technician 3+ yrs add l experience Experience Equiv 3+ yrs add l experience Specialty or Experience Equiv 2 yrs ITS INDUSTRY Experience 2 yrs ITS DESIGN Experience ITS Fundamentals Exam

Technical Writing Committees Technical Information and Methods TDMM NDRM OSP WDRM ESS A/V Codes National Electrical Code Standards ANSI-accredited ANSI/NECA/BICSI- 568-2006 ANSI/BICSI-001-2009 ANSI/NECA/BICSI- 607-2009 ANSI/BICSI-002-2010 Healthcare Electronic Safety & Security

Global Data Center Standards 1. EN 50173-5 "Information Technology - Generic Cabling Systems - Part 5: Data Centres" 2. ISO/IEC FCD 24764: "Information Technology - Generic Cabling for Data Centre Premises 3. ANSI/TIA-942 "Telecommunications Infrastructure Standard for Data Centers" ANSI/TIA-942-1 "Data Center Coaxial Cabling Specifications and Application Distances 4. ANSI/BICSI-002 "Data Center Design Standard and Recommended Practices"

CENELEC EN 50173-5 ISO/IEC CD 24764 Category 6/Class E minimum for all subsystems except ENI ENI may be Category 5/Class D or higher Copper & fiber trunks NOT addressed by this Standard Category 6 A /Class E A minimum for all subsystems except ENI ENI may be Category 5/Class D or higher Informative Annex: Copper & fiber trunks addressed by this Standard

CENELEC EN 50173-5 OM2 minimum Fiber classes OM2 & OM3 OS1 & OS2 Fiber connectors standardized IEC or CENELEC ISO/IEC CD 24764 OM1 minimum 1. SM LC angled polish @ ENI 2. If 1 or 2 MM fiber, LC @ ENI 3. If 1 or 2 MM fiber, then LC @ EO 4. If multifiber, then MPO (Array) required @ EO 1. IEC 61754-7- Part 7

Three cabling subsystems: 1. network access cabling 2. main distribution cabling 3. zone distribution cabling ISO/IEC CD 24764 & EN 50173-5

ANSI/TIA-942 "Telecommunications Infrastructure Standard for Data Centers" 1. Data Center Design Overview 2. Data Center Cabling Infrastructure 3. Data Center Telecommunications Spaces and Related Topologies 4. Data Center Cabling Systems 5. Data Center Cabling Pathways 6. Data Center Redundancy

ANSI/BICSI-002 "Data Center Design Standard & Recommended Practices" 1. Design Process 2. Space Planning 3. Redundancy 4. Site Selection 5. Architectural 6. Structural 7. Electrical 8. Mechanical 9. Fire Protection 10.Security 11.Building Automation 12.Access Providers 13.Telecom Spaces 14.Cabinets & Racks 15.Cabling Pathways 16.Cabling Systems 17.Cabling Field Testing 18.Telecom Administration 19.Information Technology 20.Commissioning 21.Maintenance

ANSI/TIA-942 Category 5e minimum for all subsystems Category 6 Recommended Copper & fiber trunks NOT addressed ANSI/BICSI-002 Category 6 minimum for all subsystems Category 6 A /Class E A Recommended Copper & fiber trunks are addressed by this Standard

ANSI/TIA-942 OM1 minimum OM3 Recommended Fiber connectors NOT specified ANSI/BICSI-002 OM2 minimum OM3 Recommended OM4 May be added Fiber connectors NOT specified

ANSI/TIA-942 & ANSI/BICSI-002 UPS up to 100 kva Permitted in computer room Larger should be located in a separate room Ceiling Height 2.6 m minimum clear height 450 mm clearance to water sprinkler heads Cable Tray Clearance 20 mm between top of tray & bottom of access floor tile Lighting 500 lux minimum Doors 1 m wide minimum 2.13 m high minimum Floor Loading 7.2 kpa minimum 12 kpa recommended Operational Parameters 20 o C to 25 o C temperature 40% to 55% humidity

CENELEC EN 50173-5 ISO/IEC FCD 24764 ANSI/TIA- 942 ANSI/BICSI- 002 Balanced Cabling Minimum (Recommended) Category 6 Class E Category6 A Class E A Category 5e (Category 6) Category 6 (Category 6 A ) Balanced Cabling Trunks Recognized NO YES NO YES Optical Fiber Cabling Minimum (Recommended) OM2 or OM3 OS1 or OS2 OM1 OS1 OM1 OS1 OM2 (OM3) OM1 Optical Fiber Cabling Trunks Recognized NO YES NO YES Optical Fiber Cabling Connectivity YES LC & ARRAY NOT SPECIFIED NOT SPECIFIED

Thank You Questions Encouraged