Working together. to prevent cable damage. a partnership for reliable and quality power



Similar documents
CHECKLIST FOR CARRYING OUT EXCAVATION AND PILING WORKS IN CHANGI/SELETAR AIRPORT

Guidelines for Excavations

AVOIDANCE OF ELECTRICAL HAZARDS WHEN WORKING NEAR OVERHEAD ELECTRIC LINES

Excavation & Trenching Procedure

Permit No. Permit Fee: $ Permit Expires (D+90 days): Business Name: Applicants Name: Telephone Number: Address:

Application of Electrical Installation Licence

How To Safely Dig For Natural Gas

APPLICATION PROCEDURES FOR PLACEMENT OF UNDERGROUND TELECOMMUNICATION CABLES IN THE VICINITY OF TRANSPORTATION FACILITIES

Procedure for Working in or around Excavations

Trenching and Excavation Safety

Transmission Business Electrical Incident & Safety Performance Reporting Guide

Excavation Procedure. MIDGA Reviewed: 07/29/14 Effective: 06/20/09 Supersedes: Original Preparer: Owner: Approver: Safety Safety Safety

Ground-borne Vibrations and Ground Settlements Arising from Pile Driving and Similar Operations

Leakage from customers supply pipes. code of practice

Civil. 2. City of Seattle Supplement to the Specification for Road, Bridge and Municipal Construction, most current addition.

High-voltage systems. Identifying high-voltage overhead conductors

APPLICATION PROCEDURES FOR PLACEMENT OF UNDERGROUND WATER AND SEWER PIPELINES IN THE VICINITY OF TRANSPORTATION FACILITIES UNDER THE

Building over or close to a public sewer

BUILDING OVER OR NEAR WATER & SEWER MAINS POLICY

Public Works Operations Manual Standard Operating Procedures for Water and Sewer WS-A412 Water Connection Repair

environment briefing02

ScottishPower Distribution Cables & Equipment. Metal Theft

Living with Electricity Easements

FIXED CHARGE: This is a cost that goes towards making the service available, including

Eric Six Heath Consultants Incorporated

SECTION SITE PREPARATION

Town of Concord Drain Layer s Requirements/Info

Building Electrical Infrastructure

Permits to Dig / Permits to Excavate / Permits to work near underground services

Workplace Safety and Health (Risk Management) Regulations

Guide for Safety with. Underground Services

Geotechnical Building Works (GBW) Submission Requirements

Triton Knoll Offshore Wind Farm Limited Electrical System. Outline Traffic Management Plan

Case Study: HV Cable Strike With Steel Pin Whilst Erecting A Marquee:

High Voltage. Hazards

APPLICATION FOR DEMOLITION & RIGHT-OF OF-WAY PERMIT

DAMAGE PREVENTION LEGISLATION ELEMENTS REQUIRED FOR CANADA

Engineering Policy 146. Severe Weather Management Plans

GUIDELINES FOR UTILITY INSTALLATIONS Part 1 - Wire Lines and Communications Cables

It was my assignment to physically inspect the 8 trees on site near the proposed construction,

your electric service: from overhead to underground

PIPELINE ROUTING PERMIT. For A NATURAL GAS PIPELINE DAKOTA AND RAMSEY COUNTIES ISSUED TO NORTHERN STATES POWER COMPANY D/B/A XCEL ENERGY

Technical Guidance Note 287. Third-party guidance for working near National Grid Electricity Transmission equipment

Competent. Person Manual. Course Preview TRENCHSAFETY

UNIVERSITY OF WISCONSIN MADISON

HIGHWAYS ACT 1980 SECTION 171 : LICENCE APPLICATION PACK. Consent to deposit building materials and making of excavations in the Public Highway

Health and safety management. Cardinus Risk Management explain why safety comes first with JobWatch powered by BigChange

DEPARTMENT OF LABOUR. No. R February 2014 OCCUPATIONAL HEALTH AND SAFETY ACT, 1993 CONSTRUCTION REGULATIONS, 2014

Accident/Incident Investigation & Reporting Procedure

General Utility Work Obligations

Electrical for Detached Garages: Updated Feb 19, 2016 for 2015 CE Code in force Jan. 1, Underground branch circuit feeding a detached garage:

Galloper Wind Farm Project. Traffic Management Plan May 2013 Draft v1 Document Reference GWF/TMP/ Galloper Wind Farm Limited

The Delivery Hub health, safety and environment Raising the bar 9 Underground service avoidance

Construction Management Statement. Residential development at Bywell House, St Mary s Hill, Ascot

Electric Engineering Division FIBER CONDUIT RULES AND REGULATIONS

Work Health and Safety (WHS) Policy

ABN Mannum Road Phone: (08) PO Box 586 Fax: (08)

Level 1 Certificate in Network Construction Operations - Gas ( )

Optical Cable Pre-Construction Survey. Keywords Stationary Reel Method, empty innerducts, sub-ducts, microducts, Intermediate-feed manholes

Standard terms and conditions

SAMPLE FRACTION MITIGATION CONTINGENCY PLAN FOR DIRECTIONAL DRILLING

A. In this chapter, the following terms have the meanings indicated.

Code of Practice For Avoiding Danger From Underground Services

INCIDENT REPORTING POLICY

CONSTRUCTION PERMIT REQUIREMENTS

Effective July 1, 2010 WYOMING STATE LAW Title 37 Public Utilities Chapter 12 Article 3. DAMAGE TO UNDERGROUND PUBLIC UTILITY FACILITIES

How To Keep An Eye On Electric Safety

Federation of Piling Specialists

Guide for Contractors and Project Supervisors

Overhead Power Line Safety for Contractors

Application for the Alteration of a Gas Supply

Guidelines for Fiber Optic Cable Permits

BUILD OVER SEWER (BOS) ASSESSMENT MANUAL

Gas Explosion at a Subway Construction Site

ICM Project Underground Infrastructure and Cable

There is no water, surface tension cracks, nor other environmental conditions present that reduce the stability of the excavation.

South East Region Leakage Code of Practice. Affinity Water Limited CODE OF PRACTICE ON LEAKAGE

The Guidance for the Management of Safety for Construction Works in Japanese ODA Projects

The Management of Asbestos containing Materials

Ontario Electrical Safety Code - Info Sheet

Safety During Power Restoration. Steve Thompson Emergency Operations Director Alabama Power Company

Corporate Standard. Contractor Management

Incident Response and Investigation Procedure

SECTION 1 GENERAL REQUIREMENTS

Earthing Guidance Notes

SECTION SUPPORT OF EXCAVATION

CONTRACTOR SAFETY MANAGEMENT PROGRAM

CenterPoint Energy responds to frequently asked questions

and the design of construction working platforms

CONSENT, PURSUANT TO SECTIONS 34A, 88, 104, 104C, and 108 OF THE RESOURCE MANAGEMENT ACT, IS GRANTED. THE FULL DECISION IS SET OUT BELOW

Transcription:

Working together to prevent cable damage a partnership for reliable and quality power

contents introduction...1 cable damage can be prevented...2 3 how you can help...4 7 good practices to do it right...8 9 qualified personnel who can help you...10 11 let s work together...12 how you can reach us...13 ACKNOWLEDGEMENTS SP PowerGrid wishes to acknowledge the following for their contributions to this publication: PHOTOGRAPHS A.J. Construction & Transportation Pte Ltd Obayashi Corporation Yu Yee Engineering Pte Ltd Mr Chia Wu Serk (James Contractor Pte Ltd) Mr Lim Hock Leong (Licensed Cable Detection Worker) REFERENCE Energy Market Authority (EMA) First Published: 2002 This Edition: September 2005

WE VALUE OUR PARTNERSHIP WITH CONTRACTORS TO INFORM, EDUCATE AND ASSIST THEM IN AVOIDING THE HIGH COST OF CABLE DAMAGE. introduction Singapore has one of the best electricity networks in the world. The network performance of the national power grid compares favourably with the best internationally. To ensure that the network continues to meet the increasingly stringent needs of our consumers, continuing efforts and investments are made to enhance the transmission and distribution of reliable and quality power. Cable damage can affect consumers in high-technology industries. A major factor contributing to good reliability and quality is the fully underground cable system that we have in place. Although such a system means that the network is protected from negative environmental effects, cables can be damaged as a result of earthworks. Cable damage can affect consumers, particularly those in high-technology industries that use voltage-sensitive equipment. These include wafer-fabrication plants and other high-technology electronics and process plants. For them, a momentary voltage dip can cause voltage-sensitive equipment to malfunction, resulting in downtime for affected production and process lines. SP PowerGrid is committed to providing a reliable and quality electricity supply. We value our partnership with contractors who carry out earthworks to inform, educate and assist them in preventing cable damage. working together to prevent cable damage a partnership for reliable and quality power [1]

Cables serve as an important link in supplying power. Contractors must be vigilant in adhering to good practices in cable damage prevention during earthworks. Earthrod/ Poles Sinking (2.5%) Boring/ Drilling Works (2.6%) Piling Works (5.2%) Manual Excavation (15.1%) Soil Subsidence (1.5%) Uprooting of Trees (0.6%) Causes of Cable Damage Others (13.0%) Mechanical Excavation (59.5%) working together to prevent cable damage a partnership for reliable and quality power [2]

MECHANICAL EXCAVATIONS ACCOUNT FOR THE MAJORITY OF CABLE DAMAGE. GOOD PRACTICES DURING EARTHWORKS CAN PREVENT SUCH OCCURRENCES. cable damage can be prevented Based on our statistics, mechanical excavation accounted for the majority of cable damage. Manual excavation was the second major cause. However, cable damage during earthworks can be prevented if good practices are followed. SP PowerGrid s Earthworks Monitoring & Cable Protection (EMCP) Section was set up to assist contractors in preventing cables from damage during earthworks. EMCP staff provide consultation and assistance to help contractors avoid cable damage. Contractors need to be always vigilant of the presence of cables and to adhere to good practices in cable damage prevention. working together to prevent cable damage a partnership for reliable and quality power [3]

Main photo: Check against cable plans for underground electricity cables in the vicinity of your earthworks. Below: Be alerted by cable slabs (left) and surface markers (right) which indicate the presence of cables. working together to prevent cable damage a partnership for reliable and quality power [4]

CABLE PLANS WILL HELP YOU AND YOUR LICENSED CABLE DETECTION WORKERS TO DETERMINE CABLE LOCATIONS PRIOR TO EARTHWORKS AND TAKE MEASURES TO PREVENT DAMAGE. how you can help There are a few simple steps you can take towards preventing cable damage: 1 Check for existence of underground electricity cables Contractors must first check for existence of underground electricity cables by referring to cable plans. These plans can be purchased from: An over-ground box is one of several indications of the presence of underground electricity cables. Earthworks Monitoring & Cable Protection Section SP PowerGrid Ltd 25 Pasir Panjang Road Singapore 117536 Company Registration No: 200306959Z Tel: 6470 0603 / 6470 0621 Fax: 6475 9400 / 6479 5660 The cable plans will help you and your Licensed Cable Detection Workers (LCDWs) to determine the presence of electricity cables at site prior to earthworks and take precautionary measures to prevent damage. You should also look out for signs indicating the presence of underground electricity cables. These include surface markers, cable slabs buried underground, cable bridges and over-ground boxes. 2 Consider cable diversion or changing earthworks positions Consider cable diversion as a pro-active measure whenever earthworks or projects affect the electricity cables extensively. Alternatively, relocate earthworks to avoid underground electricity cables. working together to prevent cable damage a partnership for reliable and quality power [5]

working together to prevent cable damage a partnership for reliable and quality power [6] EMCP officers are on-hand to advise contractors on good practices in cable damage prevention.

CONTRACTORS CAN AVOID DAMAGE TO UNDERGROUND ELECTRICITY CABLES BY FOLLOWING STATUTORY REQUIREMENTS AND IMPLEMENTING ADDITIONAL PRECAUTIONARY MEASURES AS ADVISED. how you can help 3 Comply with statutory requirements on cable damage prevention Notice for Commencement of Earthworks forms must be submitted to EMCP Section not less than 7 days prior to earthworks. Contractors must engage LCDWs to carry out cable detection works, confirm underground electricity cables, mark their locations and plot the information in the cable detection drawings. If earthworks are intended in the vicinity of highvoltage cables (6.6kV, 22kV, 66kV, 230kV or 400kV), contractors must notify SP PowerAssets not less than 7 days prior to the earthworks. This should be done by submitting the Notice for Commencement of Earthworks (NCE) form to SP PowerGrid s EMCP Section, together with the following: LCDW cable detection drawing(s) Site plan indicating the proposed work area Schedule of planned earthworks activities The NCE form can be downloaded from: www.sppowergrid.com.sg 4 Work closely with SP PowerGrid After receiving the NCEs, EMCP will arrange to meet contractors and visit their sites to evaluate the proposed earthworks. This is very important as the meeting allows for detailed discussion between contractors and EMCP officers. As a result, our staff are able to provide advice on good practices to be adopted at sites. Contractors should implement these good practices to keep underground electricity cables safe. working together to prevent cable damage a partnership for reliable and quality power [7]

Main photo: Implement a Permit-To-Work system to ensure checks at every stage for close monitoring of earthworks activities. Below: Protective measures such as proper shoring (left) and proper suspension of underground electricity cables (right) help to prevent damage to the cables. working together to prevent cable damage a partnership for reliable and quality power [8]

DUE CARE AND DILIGENCE DURING EARTHWORKS PREVENT UNDERGROUND ELECTRICITY CABLES FROM BEING DAMAGED. YOU PLAY AN IMPORTANT ROLE IN ENSURING PREVENTIVE MEASURES ARE IN PLACE. good practices to do it right Now that you are ready to begin earthworks, there are good practices that you should follow to do it right: Digging trial holes manually is a safe and effective way to locate underground electricity cables. Implement a Permit-To-Work system to manage different levels of checks at every stage for close monitoring of earthworks activities within the site. Ensure the LCDW has marked out all detected cable locations and these markings are continuously maintained. Dig trial holes manually to be positively sure that there are no electricity cables at the proposed earthworks area; and to ascertain exact locations if there are electricity cables. Engage Registered Excavator Operators (REOs) or Provisional Registered Excavator Operators (PREOs) to operate excavating equipment and/or carry out mechanical excavation. Use manual excavation whenever earthworks come to within 2 metres of underground electricity cables; in cases where premix concrete and hardcore road surfaces need to be removed, mechanical excavation under close supervision should strictly be restricted to the surface area. Provide appropriate and adequate soil control measures such as shoring and shuttering to prevent soil movement which can cause cable damage in excavated areas. Protect exposed electricity cables by enclosing them with cut PVC pipes or other protective covering to prevent tools or falling objects from accidentally damaging the cables. Contact and consult SP PowerGrid officers before proceeding with under-crossing or over-crossing of electricity cables. Call EMCP General Enquiries line whenever in doubt Tel: 6470 0603. Due care and diligence during earthworks prevent underground electricity cables from being damaged. You play an important role in ensuring preventive measures are in place. working together to prevent cable damage a partnership for reliable and quality power [9]

working together to prevent cable damage a partnership for reliable and quality power [10] Engage only Registered Excavator Operators or Provisional Registered Excavator Operators as they are trained to identify and take precautions to avoid cable damage.

LICENSED CABLE DETECTION WORKERS MUST BE ENGAGED TO CARRY OUT CABLE DETECTION WORK BEFORE EXCAVATION BEGINS. REGISTERED EXCAVATOR OPERATORS OR PROVISIONAL REOS SHOULD BE ENGAGED TO OPERATE EXCAVATORS AT EARTHWORKS SITES IN THE VICINITY OF UNDERGROUND ELECTRICITY CABLES. qualified personnel who can help you There are two categories of professional and skilled personnel who play very important roles in ensuring that earthworks are carried out safely, without damaging underground electricity cables. They are the Licensed Cable Detection Worker (LCDW) and the Registered Excavator Operator (REO) or the Provisional REO (PREO). Ensure that Licensed Cable Detection Workers mark out all cable locations before earthworks begin. The LCDW is a professional trained to detect underground electricity cables. LCDWs must be engaged to carry out detection work before earthworks begin. LCDWs are licensed by Energy Market Authority (EMA) after successfully completing a course in cable detection work. Under current requirements, such courses must be approved by EMA. Earthworks contractors are advised to engage REOs, or Provisional REOs (PREOs), to operate excavators at earthworks sites in the vicinity of underground electricity cables. PREOs are those who have attended the Underground Services Detection Course. A PREO can apply for conversion to an REO upon obtaining a certificate for the Hydraulic Excavator Operation course which covers advanced skills in excavator operation. working together to prevent cable damage a partnership for reliable and quality power [11]

let s work together The performance of Singapore s transmission and distribution network is among the best in the world. This is the result of continuing efforts and investments to expand and enhance the supply infrastructure to meet consumers needs. Singapore s power network is unique in the world in that both transmission and distribution of power are carried out via underground cables. SP PowerGrid will continue to work with contractors to protect the integrity of SP PowerAssets electricity cable network. To support, manage and monitor the vast infrastructure that we have in place, SP PowerGrid leverages on the latest technology and IT systems. We are among the first in the world to have a Grid Modelling and Planning (GMAP) system which provides a comprehensive database on underground electricity cable routes. This system provides up-to-date information on the locations of our underground electricity cables to assist contractors in preventing cable damage in the course of earthworks. We need the co-operation of earthworks contractors in working closely with us to protect the integrity of our underground electricity cable network so that reliable and quality power is available to all consumers. What to do when a cable is damaged Stop all work activities in the vicinity of the damaged cable Keep out all personnel from the area Inform SP PowerGrid s Electricity Service Centre (ESC) at our 24-hr toll-free number 1800-778-8888 Inform your LCDW Remain on-site to assist SP PowerGrid officers on their arrival Warning: Tampering with damaged underground electricity cables can cause serious injuries or even death. Do not attempt to tamper or repair damaged cables. working together to prevent cable damage a partnership for reliable and quality power [12]

how you can reach us HELP ON CABLE DAMAGE PREVENTION Earthworks Monitoring and Cable Protection Section General Enquiries... 6470 0603 Helpline on Cable Plans... 6470 0621 REPORTING CABLE DAMAGE Electricity Service Centre (24-hours)... 1800-778 8888 ENQUIRIES ON 400kV AND 230kV CABLES Extra High-Voltage Network Section... 6290 9121 ENQUIRIES ON 66kV AND BELOW CABLES Regional Network North Section... 6314 6172 Regional Network South Section... 6290 9101 Regional Network East Section... 6240 9218 Regional Network West Section... 6660 9301 Regional Network Central Section... 6279 9501 EARTHWORKS GUIDELINES & NOTICE FOR COMMENCEMENT OF EARTHWORKS FORM SP PowerGrid Website www.sppowergrid.com.sg COURSES FOR LICENSED CABLE DETECTION WORKERS AND EXCAVATOR OPERATORS Human Resource Branch... 6823 8676 LICENSED CABLE DETECTION WORKERS Energy Market Authority Website... www.ema.gov.sg working together to prevent cable damage a partnership for reliable and quality power [13]

reliable quality power SP PowerGrid Ltd 25 Pasir Panjang Road Singapore 117536 Company Registration No: 200306959Z Tel: 6470 0603 / 6470 0621 Fax: 6475 9400 / 6479 5660 Email: emcp@singaporepower.com.sg