ICM Project Underground Infrastructure and Cable

Size: px
Start display at page:

Download "ICM Project Underground Infrastructure and Cable"

Transcription

1 EB 0 00 Tab Schedule B ( pages) ICM Project Underground Infrastructure and Cable Handwell Replacement Segment (THESL)

2 EB 0 00 Tab Schedule B I EXECUTIVE SUMMARY. Project Description 0 The handwell replacement segment described in this document is required to protect the public from the potential safety risk posed by electric shocks from contact voltage. Handwells are essentially electrical junction boxes embedded in sidewalks or other pavement in which the connection is made between the secondary distribution system and street lighting or unmetered scattered loads. Owing to their location, which exposes them to corrosion from salt and water and construction damage, the handwells themselves may become a source of contact voltage and damage to the wires and connections within them may allow other equipment, such as streetlight poles to become energized. 0 There are approximately,00 handwells on the THESL system. Following the Level III emergency that THESL declared in 00 after children and pets received shocks from energized equipment, THESL began handwell replacement (See Section II, ). By the end of 0, THESL had replaced almost,00 existing handwells with new, non conducting composite handwells (See Section II, ). These replacements were concentrated in the downtown core because that is where both the number of handwells and the potential exposure to contact voltage are greatest. The segment proposed in this application is to replace the remaining handwells not addressed in prior years. This segment will first target the remaining handwells in the downtown core and then replace handwells located in the surrounding areas of North York, East York, York, Etobicoke, and Scarborough. By the end of 0, when this segment is complete, some 0 percent of handwells in the City of Toronto are expected to have been replaced. The handwells that remain to be replaced are primarily located in areas where City moratoriums prevent THESL from excavating the sidewalks or other pavement. 0 The following Table summarizes the cost of the segment.

3 EB 0 00 Tab Schedule B Table : Summary of Segment Costs Project Estimate Project Title Year Cost Estimate Number ($M) 0 Handwell Standardization and 0 $.0 Remediation 00 Handwell Standardization and 0 $. Remediation 0 Handwell Standardization and 0 $. Remediation Total: $.. Why the Project is Needed Now 0 Handwells are among the top three structures with the highest number of contact voltage hits as assessed by mobile scanning inspections (See Section III). Common causes include damage from the elements, as handwells are exposed to harsh environmental conditions, third party damage whenever the sidewalk is rebuilt or repaired, degradation of cable insulation, and substandard installation of connections. If left untreated, the public may be exposed to the potential safety risk posed by electric shock through contact voltage from the following sources: Contact of exposed conductor with metallic plates and covers; Direct contact with exposed conductor; or Indirect contact through another medium o Concrete structures (including sidewalks) o Conductive salt water saturates concrete and a voltage gradient forms o Metallic poles

4 EB 0 00 Tab Schedule B. Why the Project is the Preferred Alternative 0 Two options were evaluated to mitigate the potential safety risk associated with contact voltage: (a) Reactive Take no action and respond to contact voltage incidents. (b) Proactive Replace metal handwells with non conductive handwells. Replacements are prioritized to address the high risk areas based on proximity to the downtown core, where the majority of handwells are located (and thus where the majority of contact voltage occurrences on handwells are located), and where there is a high volume of pedestrian traffic. Proactive replacement of handwells is the preferred option as this approach will mitigate the existing public safety hazard. If the segment is not implemented, the risk of contact voltage will continue at current levels until such time as this work can be done.

5 EB 0 00 Tab Schedule B II PROJECT DESCRIPTION. Overview This segment addresses the immediate need for spending to address replacement of most handwells remaining on THESL s system. Handwells are essentially electrical junction boxes embedded in sidewalks or other pavement in which the connection is made between the secondary distribution system and street lighting or unmetered scattered loads. This segment addresses handwells whose replacement has not been funded in prior years. 0 The objective of this segment is to mitigate the potential contact voltage risk posed by the metallic handwells by replacing existing handwells with new handwells built to current standards. As discussed more fully below, this work will include installation of composite polymer concrete units, non conductive lids, gel connectors, and PVC jacketed cable. 0 Handwells are typically found in pre amalgamation Toronto, as well as dense mixed use areas in other parts of the city (e.g., downtown North York or the Etobicoke core). The secondary bus is run through ducts from handwell to handwell. In each handwell, the cable used to service the streetlight or unmetered scattered load is connected to the bus. A handwell is typically installed adjacent to each individual street lighting pole. Corrosion and other factors can cause a handwell to become energized, leading to potential contact voltage incidents.. Handwells and Contact Voltage Contact voltage is an intermittent condition when electricity or voltage is present on street equipment. Secondary electrical plant installed in the field is constantly subjected to environmental factors and susceptible to third party damage whenever the sidewalk is rebuilt or repaired. It endures water, salt and contamination ingress and wide variations in temperature. Secondary infrastructure refers to the low voltage electrical plant supplying 0/0V single phase, and 0/0V and 00/V three phase service. Secondary supply is sourced from overhead or underground mains and feeds loads ranging from residential and commercial customers to unmetered scattered loads such as bus shelters, traffic signals, and Business Improvement Area signs, and Street Lighting circuits.

6 EB 0 00 Tab Schedule B Before 00, most shocks from utility infrastructure around the world were treated as isolated incidents. Focus on the issue was heightened in 00, however, when a woman in New York City was fatally shocked after falling onto an energized metal service box cover. This fatality increased scrutiny from the public and regulators and triggered a wide scale awareness of contact voltage issues. In February 00, Toronto Hydro declared a Level III Emergency after of one dog was fatally shocked in November 00, and children and another dog received shocks in early 00. As a result, Toronto Hydro made a decision to inspect and make safe all handwells and handholes in Toronto. 0 As shown in Figure, handwells and the wiring within them can corrode due to age and environmental factors. Handwell covers can also corrode (See Figure a, below). This corrosion and degradation of components eventually causes the integrity of the connections to deteriorate to the extent that live electrical wires become exposed. This can create a potential safety risk to the public, such as those that led THESL to develop and implement an emergency management plan, internally known as the Level III Emergency response. Figure Open Handwell Photographed During Inspections

7 EB 0 00 Tab Schedule B THESL proposes replacing existing handwells with new non conductive handwells and lids. The conductive metal covers still found on many handwells are shown in Figure a. In THESL s proposal, these conductive lids will be replaced with the non conductive lids and composite handwells as shown in Figure b. Figure a Metal Handwell Lids Figure b Non Conductive Lids and Composite Handwell

8 EB 0 00 Tab Schedule B Figure Degraded Conditions of Split Bolt Connectors in Handwells Figure shows an exposed connection of a split bolt connecter wrapped in layers of poly vinyl chloride (PVC) tape and self amalgamative plastic (SAP). Specific procedures have been defined on the amount of PVC and SAP tape required, however this leaves room for human error if not wrapped according to the approved standard and can result in connections with insufficient insulation. Figure displays the new gel connectors introduced to prevent the seepage of water and other contaminants thus eliminating the need for the taped split bolt connections.

9 EB 0 00 Tab Schedule B Figure New Handwell Connectors Figure Repaired Cable Figure shows a damaged bus cable that has been repaired with PVC and SAP tape. For improved insulation, the bus cable specifications have been revised to require a double insulation cable with a PVC jacket instead of the single insulation cable used previously.

10 EB 0 00 Tab Schedule B III NEED Despite the work done in response to the 00 Level III Emergency (during which time THESL undertook a comprehensive city wide handwell inspection program), contact voltage remains an issue for pedestrians and pets in the City of Toronto. Contact voltage is most likely to occur in wet, icy, and salty conditions. The potential risk of contact voltage typically occurs in the winter and early spring, when salt is used most and when there is great deal of moisture and other contamination penetrating the handwells. 0 Since the Level III Emergency, THESL has launched a number of initiatives to prevent contact voltage incidents. These include: Adopting designs that no longer include handwells for new installations. Introducing new materials to combat environmental stresses including gel connectors, polymeric concrete handwells, and non conductive handwell lids. Revising Construction Standards to require new materials. Developing Standard Practices for crews to follow when conducting maintenance on connections in handwells to mitigate the risk of these assets becoming energized. Developing Standard Practice for classifying and addressing contact voltage occurrences identified through mobile surveying. 0 To further reduce the risk of contact voltage, THESL must also undertake the replacement of metal handwells proposed here. There have been a number of incidents and data to support the potential safety risks that handwells present. Since 00, THESL has been classifying and addressing contact voltage occurrences proactively identified through mobile surveying, which is performed by an external contractor. Figure shows that the number of scanned contact voltage hits has decreased each year since 00, while Figure shows that since 00, the average level of contact voltage detected has decreased by 0%.

11 EB 0 00 Tab Schedule B Figure Historical Contact Voltage Hits Identified by Mobile Surveying Figure Average Level of Contact Voltage Detected Figure shows traffic lights, handwells and street lights among the top three sources of contact voltage hits. 0

12 EB 0 00 Tab Schedule B Number of Contact Voltage Hits by Asset in 0 Figure 0 Results by Asset Class Additionally, Table shows the number of energized (greater than volt) handwells detected in THESL s service territory. Table Number of Energized Handwells Year Three of Energized Handwells Detected (> Volt) 00 (Note: scanning commenced partway through 00) 00, 0, 0 (Note: includes results up to the end of March 0) Any contact voltage occurrences that are not proactively detected through mobile scanning have the potential to harm members of the public. In 0, there were eight recorded handwell

13 EB 0 00 Tab Schedule B contact voltage incidents which resulted in claims against THESL. These incidents are listed in Table. Table Contact Voltage Incidents on Handwells (0) Date Location Description of Incident January Wellesley/Bay Dog shocked January Bay/Elm Dog shocked January Yonge/St. Clair Dog shocked January York/King/Wellington Person shocked February Danforth Avenue Dog shocked March Eglinton/Scarlett Dog and person shocked March Danforth Avenue Dog shocked August McGill Dog shocked

14 EB 0 00 Tab Schedule B IV PREFERRED ALTERNATIVE. Project Description The Handwell Replacement program will replace the above components which were installed based on previous standards with new components meeting the current standards. This work is intended to enhance public safety by mitigating the potential risk of contact voltage through ongoing handwell replacements. This approach is preferred, as opposed to deferring the required work to some later date and not mitigating potential safety risks. 0 This work begins by addressing the highest risk areas in the downtown core due to higher pedestrian traffic and a greater number of handwells with a resulting concentration of contact voltage occurrences. THESL will then begin replacement in other areas of the City with handwells that are identified as not being constructed to current standards. The cost of this approach is an estimated $. million to remediate about,00 handwells. This is expected to result in replacement of the vast majority of metal handwells, thereby reducing the potential safety risk of contact voltage to the public. 0 The alternative to the proposed replacement program would be to replace handwells reactively when specific instances of contact voltage are identified, or if they fall within the scope of a related distribution project. While this option would defer capital expenditures, it will also result in a higher potential public safety risk. As the existing handwells continue to age and the condition of the cables within them continues to deteriorate, an increase in contact voltage occurrences is expected, further compounding the risk. 0 Moreover, even if this work is deferred in the short term, the existing handwells eventually will require replacement due to their deteriorated condition. Reactive replacement costs may also be higher for locations identified during contact voltage scans due to the costs of after hours work and delays in permitting. THESL believes that it is prudent to complete this work in the near term in order to address the potential safety risk.

15 EB 0 00 Tab Schedule B. Project Scope and Cost Handwell replacement typically involves the following tasks: Excavation and removal of legacy handwells Replacement of active handwells with non conductive units Replacement of underground secondary mains cable with a superior, dual insulation cable Remaking all connections in handwells to the current standard 0 Forecast costs are based on an average a handwell replacement cost of approximately $,00 per unit and do not include unforeseen locations requiring remediation. Table : Handwells Summary of Project Costs Project Estimate Project Title Project Year Cost Estimate Number ($M) 0 Handwell Standardization and 0 $.0 Remediation 00 Handwell Standardization and 0 $. Remediation 0 Handwell Standardization and 0 $. Remediation Total: $.

SUMMARY OF DISTRIBUTION INTEGRITY MANAGEMENT PROGRAM

SUMMARY OF DISTRIBUTION INTEGRITY MANAGEMENT PROGRAM Page 1 of 9 SUMMARY OF DISTRIBUTION INTEGRITY MANAGEMENT PROGRAM Program Overview: The Distribution Integrity Management Program ( DIMP ) activities are focused on obtaining and evaluating information

More information

Detection of Contact Voltage in Electric Distribution Systems

Detection of Contact Voltage in Electric Distribution Systems Detection of Contact Voltage in Electric Distribution Systems David Kalokitis CTO dkalokitis@powersurveyco.com Power Survey Company www.powersurveyco.com (888) PSC-2008 Who is Power Survey Company? Core

More information

ICM Project Station Infrastructure and Equipment

ICM Project Station Infrastructure and Equipment EB 0 00 Schedule B. ( pages) ICM Project Station Infrastructure and Equipment (THESL) EB 0 00 Schedule B. I EXECUTIVE SUMMARY 0. Project Description Many Municipal Substations (MS) located outside of downtown

More information

Electrical for Detached Garages: Updated Feb 19, 2016 for 2015 CE Code in force Jan. 1, 2016. Underground branch circuit feeding a detached garage:

Electrical for Detached Garages: Updated Feb 19, 2016 for 2015 CE Code in force Jan. 1, 2016. Underground branch circuit feeding a detached garage: Electrical for Detached Garages: Updated Feb 19, 2016 for 2015 CE Code in force Jan. 1, 2016 * Garage construction requires permits (electrical, building) * Permits must be applied for at the time. * Dial

More information

NETWORK OUTPUT MEASURES METHODOLOGY Authors: National Grid, SP Transmission PLC, Scottish Hydro Electric Transmission Limited

NETWORK OUTPUT MEASURES METHODOLOGY Authors: National Grid, SP Transmission PLC, Scottish Hydro Electric Transmission Limited NETWORK OUTPUT MEASURES METHODOLOGY Authors: National Grid, SP Transmission PLC, Scottish Hydro Electric Transmission Limited TABLE OF CONTENTS 1.0 Purpose and Scope...2 1.1 Methodology Purpose...2 2.0

More information

Union County Public Schools. Facilities Department. Electrical. Safe Work Practices

Union County Public Schools. Facilities Department. Electrical. Safe Work Practices 1 Union County Public Schools Facilities Department Electrical Safe Work Practices 2 Purpose In accordance with OSHA Standards 1910.331-335, safety-related work practices shall be used by Union County

More information

ScottishPower Distribution Cables & Equipment. Metal Theft

ScottishPower Distribution Cables & Equipment. Metal Theft ScottishPower Distribution Cables & Equipment Metal Theft April 2012 As an aid to deterring to metal theft this booklet has been put together to help identify the types of utility power cables and associated

More information

DISTRIBUTION OPERATIONS AND MAINTENANCE

DISTRIBUTION OPERATIONS AND MAINTENANCE EB-00-00 Filed: 00 Aug Page of DISTRIBUTION OPERATIONS AND MAINTENANCE PREVENTIVE MAINTENANCE Preventive Maintenance is intended to maintain or improve customer service reliability, extend equipment life

More information

NETWORK OUTPUT MEASURES METHODOLOGY Authors: National Grid, SP Transmission Limited, Scottish Hydro Electric Transmission Limited

NETWORK OUTPUT MEASURES METHODOLOGY Authors: National Grid, SP Transmission Limited, Scottish Hydro Electric Transmission Limited NETWORK OUTPUT MEASURES METHODOLOGY Authors: National Grid, SP Transmission Limited, Scottish Hydro Electric Transmission Limited TABLE OF CONTENTS 1.0 Purpose and Scope...2 1.1 Methodology Purpose...2

More information

Toronto Hydro-Electric System Limited ( THESL ) 2011-2020 Electrical Distribution Capital Plan

Toronto Hydro-Electric System Limited ( THESL ) 2011-2020 Electrical Distribution Capital Plan Toronto Hydro-Electric System Limited EB-2010-0142 Exhibit D1 Tab 8 Schedule 10 ORIGINAL (33 pages) Toronto Hydro-Electric System Limited ( THESL ) 2011-2020 Electrical Distribution Capital Plan June 2010

More information

Vision Home Inspection

Vision Home Inspection Vision Home Inspection 324 Rams Run Shepherdsville KY 40165-7877 Inspector: James McFadden Property Inspection Report Client(s): Property address: Inspection date: View report summary This report is the

More information

Electrical Grounding. Appendix C

Electrical Grounding. Appendix C Appendix C Electrical Grounding Low-Voltage Equipment Grounding The most frequently cited Office of Safety and Health Administration (OSHA) electrical violation is improper occupational grounding of equipment

More information

University of Iowa Main Power Plant 2008 Flood Preparations, Event, & Recovery

University of Iowa Main Power Plant 2008 Flood Preparations, Event, & Recovery University of Iowa Main Power Plant 2008 Flood Preparations, Event, & Recovery Yellow Alert for Mayflower Residence hall Peak at 31.5 feet Power Plant floods from steam tunnel and shuts down 1993 Flood

More information

STREETLIGHT SYSTEM GROUNDING AND BONDING

STREETLIGHT SYSTEM GROUNDING AND BONDING Page: 1 of 8 STREETLIGHT SYSTEM GROUNDING AND BONDING 1. Scope This Construction Standard covers the grounding and bonding requirements for single phase streetlight systems served by the Looped Radial

More information

Underground Storage Tanks

Underground Storage Tanks Underground Storage Tanks An Informational and Guidance Document for the University Community. Please contact Yale Environmental Health and Safety for latest Regulatory Requirements. A typical UST installation

More information

SECTION 18370 SIGNAL WIRE AND CABLE

SECTION 18370 SIGNAL WIRE AND CABLE SECTION 18370 PART 1 - GENERAL 1.01 DESCRIPTION A. Section includes requirements for all cable and wire required for signal and signal power system wiring to wayside shelters, junction boxes, and factory

More information

CTI TECHNICAL BULLETIN Number 9: A publication of the Cable Tray Institute

CTI TECHNICAL BULLETIN Number 9: A publication of the Cable Tray Institute CTI TECHNICAL BULLETIN Number 9: A publication of the Cable Tray Institute Cable Tray Wiring Systems Have Many Cost Advantages Cost is usually a major consideration in the selection of a wiring system.

More information

The National Armored Cable Manufacturers Association Presents. Installation Standard for Types AC and MC Cables

The National Armored Cable Manufacturers Association Presents. Installation Standard for Types AC and MC Cables The National Armored Cable Manufacturers Association Presents Installation Standard for Types AC and MC Cables An ANSI Standard Original document jointly produced by NECA and NACMA as Standard for Installing

More information

REPLACEMENT AIR CONDITIONING UNITS FOR BRITISH EMBASSY RESIDENCE

REPLACEMENT AIR CONDITIONING UNITS FOR BRITISH EMBASSY RESIDENCE REPLACEMENT AIR CONDITIONING UNITS FOR BRITISH EMBASSY RESIDENCE FOREIGN & COMMENWEALTH OFFICE BE BAHRAIN TEL: MAY 2014 EMAIL: TENDER ISSUE: 002/2014 1. GENERAL REQUIREMENTS 1.01 LOCATION OF SITE The British

More information

Evaluating Water-Damaged Electrical Equipment

Evaluating Water-Damaged Electrical Equipment Evaluating Water-Damaged Electrical Equipment 1 USE OF THIS PUBLICATION This publication provides information on how to evaluate electrical equipment that has been exposed to water through flooding, fire

More information

2014 ELECTRIC SYSTEM RELIABILITY REPORT CITY OF ANAHEIM PUBLIC UTILITIES DEPARTMENT

2014 ELECTRIC SYSTEM RELIABILITY REPORT CITY OF ANAHEIM PUBLIC UTILITIES DEPARTMENT 2014 ELECTRIC SYSTEM RELIABILITY REPORT CITY OF ANAHEIM PUBLIC UTILITIES DEPARTMENT Contents Overview... 3 1.0 Electric System Reliability... 4 1.1 Annual Reliability Data with Utility Comparisons... 4

More information

What Are the Qualifications to Conduct Arc Flash Studies? Where Do You Begin?

What Are the Qualifications to Conduct Arc Flash Studies? Where Do You Begin? What Are the Qualifications to Conduct Arc Flash Studies? Where Do You Begin? Comparing apples-to-apples bids Plant Services Special Report A shock hazard analysis should be included as part of an arc

More information

The optimum material solution for Low Voltage energy cables

The optimum material solution for Low Voltage energy cables The optimum material solution for Low Voltage energy cables About Borealis and Borouge Borealis is a leading provider of innovative solutions in the fields of polyolefins, base chemicals and fertilizers.

More information

Heading FACT SHEET. Overview. www.safeworkaustralia.gov.au

Heading FACT SHEET. Overview. www.safeworkaustralia.gov.au ELECTRICAL RISKS AT THE WORKPLACE Heading FACT SHEET Overview This fact sheet provides general guidance for persons conducting a business or undertaking (PCBUs) and workers on managing electrical risks

More information

ALUMINUM ELECTRICAL WIRING

ALUMINUM ELECTRICAL WIRING ALUMINUM ELECTRICAL WIRING prepared by Fire Prevention and Investigation Division Denver Fire Department Department of Safety and Electrical Inspections Section Denver Building Inspection Division Community

More information

PRODUCT / APPLICATION INFORMATION

PRODUCT / APPLICATION INFORMATION Abstract This paper will discuss performance life testing and stability testing used for self-regulating heating cables. It will show how the techniques were developed and evolved from the 970 s to the

More information

Measuring the Condition of Prestressed Concrete Cylinder Pipe

Measuring the Condition of Prestressed Concrete Cylinder Pipe Measuring the Condition of Prestressed Concrete Cylinder Pipe John Marshall, P.E.I, I J.W. Marshall and Associates, and Paul S. Fisk, President NDT Corporation Introduction Prestressed Concrete Cylinder

More information

Trimming Trees Near Electric Lines. Understanding Niagara Mohawk s Role and Responsibilities

Trimming Trees Near Electric Lines. Understanding Niagara Mohawk s Role and Responsibilities Trimming Trees Near Electric Lines Understanding Niagara Mohawk s Role and Responsibilities Staying Connected If you ve called Niagara Mohawk with a tree-trimming request, you know we ask a lot of questions.

More information

APPENDIX J GAS DISTRIBUTION

APPENDIX J GAS DISTRIBUTION APPENDIX J GAS DISTRIBUTION Ji Jii APPENDIX J GAS DISTRIBUTION NEIL G. THOMPSON, PH.D. 1 SUMMARY The natural gas distribution system includes 2,785,000 km (1,730,000 mi) of relatively small-diameter, low-pressure

More information

SnoTrace KSR Surface Snow and Ice Melting INSTALLATION PROCEDURES

SnoTrace KSR Surface Snow and Ice Melting INSTALLATION PROCEDURES SnoTrace Surface Snow and Ice Melting INSTALLATION PROCEDURES SnoTrace INSTALLATION PROCEDURES Refer to the SnoTrace Cable Testing Report for required recording of test data and circuit information. Upon

More information

**ATTENTION** WE DO NOT PROMOTE OR ENCOURAGE YOU TO DO YOUR OWN ELECTRICAL WIRING!!! IT IS BY FAR THE MOST DANGEROUS THING YOU CAN ATTEMPT

**ATTENTION** WE DO NOT PROMOTE OR ENCOURAGE YOU TO DO YOUR OWN ELECTRICAL WIRING!!! IT IS BY FAR THE MOST DANGEROUS THING YOU CAN ATTEMPT **ATTENTION** WE DO NOT PROMOTE OR ENCOURAGE YOU TO DO YOUR OWN ELECTRICAL WIRING!!! IT IS BY FAR THE MOST DANGEROUS THING YOU CAN ATTEMPT. YOU COULD PUT YOUR FAMILY AND WORLDLY POSSESSIONS IN DANGER!!!

More information

ELEVATOR TRAVELING CABLE - DESIGN EVOLUTION

ELEVATOR TRAVELING CABLE - DESIGN EVOLUTION ELEVATOR TRAVELING CABLE - DESIGN EVOLUTION by Richard Laney Introduction Elevator traveling cable is a vital link between the elevator car and controller. In conventional elevators, all power and signal

More information

Electric Service Guide for Residential Construction

Electric Service Guide for Residential Construction Electric Service Guide for Residential Construction Table of Contents Contacting KCP&L... 2 Existing Home Remodeling or Additions... 2 Changing your electric service... 2 What you need to know before you

More information

HAZARDS, INCLUDING SHOCK, ARC FLASH AND FIRE

HAZARDS, INCLUDING SHOCK, ARC FLASH AND FIRE Appendix B-2 - Electrical Safety In Design Final Report TECHNOLOGIES THAT REDUCE LIKELIHOOD OF INJURY FROM ELECTRICAL HAZARDS, INCLUDING SHOCK, ARC FLASH AND FIRE The following are technologies that reduce

More information

DEPARTMENT OF CODES AND BUILDING SAFETY FLOOD RECOVERY INFORMATION

DEPARTMENT OF CODES AND BUILDING SAFETY FLOOD RECOVERY INFORMATION May 2010 DEPARTMENT OF CODES AND BUILDING SAFETY FLOOD RECOVERY INFORMATION GUIDELINES FOR PERMITS ASSOCIATED WITH THE REPAIR OF FLOOD DAMAGED HOMES AND BUILDINGS The Department of Codes and Building Safety

More information

GUIDELINES FOR WATER-DAMAGED ELECTRICAL EQUIPMENT

GUIDELINES FOR WATER-DAMAGED ELECTRICAL EQUIPMENT GUIDELINES FOR HANDLING WATER-DAMAGED ELECTRICAL EQUIPMENT NATIONAL ELECTRICAL MANUFACTURERS ASSOCIATION 1300 NORTH 17 TH STREET, SUITE 1752 ROSSLYN, VIRGINIA 22209 703 841-3200 703 841-5900 FAX WWW.NEMA.ORG

More information

Winterizing Your Building

Winterizing Your Building Winterizing Your Building DEC Author: Steven J. Susca This article was originally published in the Hoffmann Architects Journal in Issue 3, 2009. As spring thaws uncover the ravages winter weather has wreaked

More information

East Central College 14434.03 HANSEN HALL LEVEL 300/400 RENOVATIONS PACKAGE

East Central College 14434.03 HANSEN HALL LEVEL 300/400 RENOVATIONS PACKAGE SECTION 260519 - BUILDING WIRE AND CABLE PART 1 - GENERAL 1.1 WORK INCLUDES A. Base and Alternate Bids: 1. Contractor Provide: a. Building wire and cable as shown on drawings or specified including feeders,

More information

Questions and Answers for Heating and A/C Contractors

Questions and Answers for Heating and A/C Contractors 1. How do we accomplish grounding of furnaces and / or water heaters on two wire circuits? 250.134 Equipment Fastened in Place or Connected by Permanent Wiring Methods (Fixed) Grounding. Unless grounded

More information

INDUSTRY WIDE LABOR-MANAGEMENT SAFETY COMMITTEE SAFETY BULLETIN #23

INDUSTRY WIDE LABOR-MANAGEMENT SAFETY COMMITTEE SAFETY BULLETIN #23 INDUSTRY WIDE LABOR-MANAGEMENT SAFETY COMMITTEE SAFETY BULLETIN #23 GUIDELINES FOR WORKING WITH PORTABLE POWER DISTRIBUTION SYSTEMS AND OTHER ELECTRICAL EQUIPMENT "ADDENDUM C" WORKING WITH 480 VOLT SYSTEMS

More information

ELECTRICAL SAFETY RISK ASSESSMENT

ELECTRICAL SAFETY RISK ASSESSMENT ELECTRICAL SAFETY RISK ASSESSMENT The intent of this procedure is to perform a risk assessment, which includes a review of the electrical hazards, the associated foreseeable tasks, and the protective measures

More information

Complete Solar Photovoltaics Steven Magee. Health and Safety

Complete Solar Photovoltaics Steven Magee. Health and Safety Health and Safety Health and safety around solar photovoltaic systems is very important. In the DC circuit you will find up to 600 volts in residential and commercial systems. In utility systems you may

More information

EARTHING AND BONDING AT SECONDARY SUBSTATIONS

EARTHING AND BONDING AT SECONDARY SUBSTATIONS DISTRIBUTION CONSTRUCTION MANUAL SECTION 4 - SUBSTATIONS ISSUE B SEPT 1996 4.4.4 EARTHING AND BONDING AT SECONDARY SUBSTATIONS 1 SCOPE This section of the Distribution Construction Manual lays down the

More information

INDUSTRIAL AND COMMERCIAL SERVICE TRANSFORMER & METERING INSTALLATION SPECIFICATION

INDUSTRIAL AND COMMERCIAL SERVICE TRANSFORMER & METERING INSTALLATION SPECIFICATION INDUSTRIAL AND COMMERCIAL SERVICE TRANSFORMER & METERING INSTALLATION SPECIFICATION February 2013 NOTE: If conflict exists between St. Thomas Energy s Conditions of Service and this document, the Conditions

More information

Approved Meter Sockets and Cabinets

Approved Meter Sockets and Cabinets Single Unit Residential Guide 1 PHASE, 120/240 VOLT S METERING (Metering sockets and cabinets are supplied by Customer). Outdoor meter mounting height is 1730 mm ( 5 8 ) to center of meter ± 100 mm ( 4

More information

The Electrical Safety Regulation (pre and post 1 January 2014)

The Electrical Safety Regulation (pre and post 1 January 2014) The Electrical Safety Regulation (pre and post 1 January 2014) The following table provides an overview comparison between the Electrical Safety Regulation 2002 (the ESR 2002) current as at 1 July 2013

More information

Voltage Detection and Indication by Electric Field Measurement

Voltage Detection and Indication by Electric Field Measurement Voltage Detection and Indication by Electric Field Measurement William McNulty, P.E. Technical Director Voltage Detection and Indication by Electric Field Measurement William McNulty, P.E. HD Electric

More information

Report on Orange and Rockland Utilities, Inc. s Implementation of the Electric Safety Standards For the 12-Month Period Ending on November 30, 2005

Report on Orange and Rockland Utilities, Inc. s Implementation of the Electric Safety Standards For the 12-Month Period Ending on November 30, 2005 Report on Orange and Rockland Utilities, Inc. s Implementation of the Electric Safety Standards For the 12-Month Period Ending on November 30, 2005 Case 04-M-0159 Pearl River, NY January 15, 2006 Table

More information

What are the basic electrical safety issues and remedies in solar photovoltaic installations?

What are the basic electrical safety issues and remedies in solar photovoltaic installations? What are the basic electrical safety issues and remedies in solar photovoltaic installations? Presented by: Behzad Eghtesady City of Los Angeles Department of Building and Safety Topics Covered Photovoltaic

More information

Leica DIGISYSTEM TM Safe and fast location of underground services

Leica DIGISYSTEM TM Safe and fast location of underground services Leica DIGISYSTEM TM Safe and fast location of underground services Find it or avoid it the Leica DIGISYSTEM is your Key Why locate Brownfield sites have many and varied installed services and utilities

More information

Steel Pole & Tower Assessment & Remediation Turnkey Solutions for Aging Steel Infrastructure

Steel Pole & Tower Assessment & Remediation Turnkey Solutions for Aging Steel Infrastructure Steel Pole & Tower Assessment & Remediation Turnkey Solutions for Aging Steel Infrastructure Understanding and Addressing the Risks of Aging Steel T&D Assets Once thought to be permanent structures free

More information

RayClic Connection System Installation Instructions

RayClic Connection System Installation Instructions F M -W RayClic Connection System Installation Instructions RayClic WARNING: Shock Hazard 718K Pipe Heating Cable with HWAT, IceStop, also Listed De-icing and and XL-Trace heating Snow Melting Equipment

More information

University of Missouri Hospitals and Clinics. Structural Repair and Protection of Post-tensioned Parking Garage

University of Missouri Hospitals and Clinics. Structural Repair and Protection of Post-tensioned Parking Garage University of Missouri Hospitals and Clinics Structural Repair and Protection of Post-tensioned Parking Garage 1 University of Missouri Project The University of Missouri Health Care Patient and Visitor

More information

ITE/IMSA 2014 Spring Meeting March 6, 2014 Signal Maintenance Practices. Bruce E. Littleton, PE, PTOE Traffic Engineering Supervisor

ITE/IMSA 2014 Spring Meeting March 6, 2014 Signal Maintenance Practices. Bruce E. Littleton, PE, PTOE Traffic Engineering Supervisor ITE/IMSA 2014 Spring Meeting March 6, 2014 Signal Maintenance Practices Bruce E. Littleton, PE, PTOE Traffic Engineering Supervisor Traffic Signal Shop Mission Statement Construct, modify and maintain

More information

MTA UNIVERSAL STATION PEDESTRIAN BRIDGE Los Angeles, CA. Project Manual and Specification 100% PE SUBMITTAL TABLE OF CONTENTS

MTA UNIVERSAL STATION PEDESTRIAN BRIDGE Los Angeles, CA. Project Manual and Specification 100% PE SUBMITTAL TABLE OF CONTENTS Los Angeles, CA Project Manual and Specification DIVISION 1 GENERAL CONDITIONS 01 01 10 STATEMENT OF WORK 01 11 00 SUMMARY OF THE WORK 01 14 05 METRO (OWNER) - DIRECTED STOPPAGES 01 20 00 PRICE AND PAYMENT

More information

Report in respect of. Service Disruption on 9 April 2012

Report in respect of. Service Disruption on 9 April 2012 Report in respect of Service Disruption on 9 April 2012 1. Introduction On 9 April 2012, a power outage occurred in the Shatin Switching Centre, one of three switching centres deployed by SmarTone Mobile

More information

OPERATIONS CAPITAL. The Operations Capital program for the test years is divided into two categories:

OPERATIONS CAPITAL. The Operations Capital program for the test years is divided into two categories: Filed: September 0, 00 EB-00-0 Tab Schedule Page of OPERATIONS CAPITAL.0 INTRODUCTION Operations Capital funds enhancements and replacements to the facilities required to operate the Hydro One Transmission

More information

Unarmored Variable Frequency Drive (VFD) Cable Termination Guide

Unarmored Variable Frequency Drive (VFD) Cable Termination Guide Authorized Distributor Unarmored Variable Frequency Drive (VFD) Cable Termination Guide Be Certain with Belden A Step-by-Step Look at the Connection/Termination of Unarmored VFD Cables Terminating Unarmored

More information

Session Five: Modern XLPE Materials for Extruded Energy Cable Systems

Session Five: Modern XLPE Materials for Extruded Energy Cable Systems Session Five: Modern XLPE Materials for Extruded Energy Cable Systems Abstract Hakan Lennartsson Senior Technical Service Manager, Borouge Hong Kong Pte. Ltd. The first medium voltage cables using extruded

More information

TS 813 GROUNDING AND BONDING TTD 813.001 TRAFFIC SIGNAL INSTALLATION AND CONTROLLER CABINET GROUNDING SYSTEM TTD 813.005 CONTROLLER CABINET GROUNDING

TS 813 GROUNDING AND BONDING TTD 813.001 TRAFFIC SIGNAL INSTALLATION AND CONTROLLER CABINET GROUNDING SYSTEM TTD 813.005 CONTROLLER CABINET GROUNDING TORONTO TRANSPORTATION January 2012 TS 813 GROUNDING AND BONDING TABLE OF CONTENTS 1. DRAWINGS TTD 813.001 TRAFFIC SIGNAL INSTALLATION AND CONTROLLER CABINET GROUNDING SYSTEM TTD 813.005 CONTROLLER CABINET

More information

City of Buffalo Municipal Electric Utility Energy Emergency Response

City of Buffalo Municipal Electric Utility Energy Emergency Response City of Buffalo Municipal Electric Utility Energy Emergency Response Table of Contents Page 1. Goals 2 2. Types of Energy Emergencies..3 3. Utility Emergency Operating Plans.4 4. Link to General Reliability/Outage

More information

UNDERSTANDING. C&M Corporation 51 South Walnut Street, Wauregan, CT 06387 Phone: 860.774.4812 Fax: 860.774.7330 www.cmcorporation.

UNDERSTANDING. C&M Corporation 51 South Walnut Street, Wauregan, CT 06387 Phone: 860.774.4812 Fax: 860.774.7330 www.cmcorporation. UNDERSTANDING UNDERSTANDING NFPA 79 By Ned Lloyd and Mike Levesque NFPA-79 is the electrical standard that has been developed by the National Fire Protection Association (NFPA) and is intended to minimize

More information

What s up with Arc Flash?

What s up with Arc Flash? What s up with Arc Flash? Presented by Mark Haskins, CSP Practical Safety Solutions, LLC CONN OSHA Breakfast Roundtable February 18, 2014 2014 Practical Safety Solutions, LLC What is Arc Flash? Definition

More information

IN USE: CABLE AGING MANAGEMENT

IN USE: CABLE AGING MANAGEMENT IN USE: CABLE AGING MANAGEMENT ISSUE STATEMENT Concerns exist that cable aging-related failures may impact nuclear plant safety and reliability. As a result, plant owners and regulators are requiring the

More information

Site Inspection Report

Site Inspection Report Site Inspection Report Project Title: 1 Canada Square Location: 1 Canada Square, Canary Wharf, London Date of Inspection: 16/05/12 System / Products: TBA (suggested flame free application) Attendees: G

More information

Electrical Hazards. Power Tools. Extension Cords

Electrical Hazards. Power Tools. Extension Cords Electrical Hazards Electrical hazards can be found in nearly every roofing work site. Whether the hazard is posed by worn or damaged power tools or cords, improperly grounded tools or equipment, or the

More information

Project Name 2012 2013 2014 Engineering Capital 9.50 9.50 9.50 Worst Performing Feeder 6.10 24.50 24.50 Customer Connections (net of Customer

Project Name 2012 2013 2014 Engineering Capital 9.50 9.50 9.50 Worst Performing Feeder 6.10 24.50 24.50 Customer Connections (net of Customer EB 0 00 Tab Schedule C Page of I OPERATIONS PORTFOLIO CAPITAL OVERVIEW THESL s Operations Portfolio Capital is made up of the following components: Engineering Capital Worst Performing Feeder Capital Customer

More information

Cable Limiters. Increase System Reliability Decrease Downtime PRODUCT GUIDE

Cable Limiters. Increase System Reliability Decrease Downtime PRODUCT GUIDE Limiters Increase System Reliability Decrease Downtime PRODUCT GUIDE Mersen Limiters Increase system reliability and versatility with Mersen Limiters. Increase system reliability and versatility with Mersen

More information

The Concrete Life Cycle: Maintain to Sustain. Fred Goodwin BASF Construction Chemicals (EB-N) Beachwood OH

The Concrete Life Cycle: Maintain to Sustain. Fred Goodwin BASF Construction Chemicals (EB-N) Beachwood OH The Concrete Life Cycle: Maintain to Sustain Fred Goodwin BASF Construction Chemicals (EB-N) Beachwood OH What is Concrete? Concrete: Instant rock -just add water to make a hard wet sponge. A composite

More information

TRANSMISSION BUSINESS PERFORMANCE

TRANSMISSION BUSINESS PERFORMANCE Filed: 0-0- Tx 0-0 Rates Tab Schedule Page of TRANSMISSION BUSINESS PERFORMANCE.0 INTRODUCTION 0 Hydro One is focused on the strategic goals and performance targets in the area of safety, customer satisfaction,

More information

Electric Service Guide for Commercial Construction

Electric Service Guide for Commercial Construction Electric Service Guide for Commercial Construction Contents Contacting KCP&L... 2 Voltages... 2 Temporary Service... 2 Customer-Provided Temporary Service... 2 KCP&L-Provided Temporary Service.... 2 Current

More information

Oscar E. Morel UtilX Corporation

Oscar E. Morel UtilX Corporation Oscar E. Morel UtilX Corporation Time Domain Reflectometry (TDR) has been the preferred technique to assess: Cable length Splice number and spatial location, and Metallic neutral condition Tests for neutral

More information

)454, !,5-).)5- #!",% 3(%!4(3 #/.3425#4)/. ).34!,,!4)/.!.$ 02/4%#4)/. /& #!",%3!.$ /4(%2 %,%-%.43 /& /543)$% 0,!.43. )454 Recommendation,

)454, !,5-).)5- #!,% 3(%!4(3 #/.3425#4)/. ).34!,,!4)/.!.$ 02/4%#4)/. /& #!,%3!.$ /4(%2 %,%-%.43 /& /543)$% 0,!.43. )454 Recommendation, INTERNATIONAL TELECOMMUNICATION UNION )454, TELECOMMUNICATION STANDARDIZATION SECTOR OF ITU #/.3425#4)/. ).34!,,!4)/.!.$ 02/4%#4)/. /& #!",%3!.$ /4(%2 %,%-%.43 /& /543)$% 0,!.43!,5-).)5- #!",% 3(%!4(3

More information

BUILDERS AND CONTRACTORS GUIDE FOR ELECTRIC SERVICE

BUILDERS AND CONTRACTORS GUIDE FOR ELECTRIC SERVICE BUILDERS AND CONTRACTORS GUIDE FOR ELECTRIC SERVICE Toll Free Telephone Numbers Residential Services 800.454.3853 Commercial Services 800.653.5307 Utility Locating Company N.C. 800.632.4949 S.C. 888.721.7877

More information

ELECTRICAL INSULATION TESTING OF HV EQUIPMENT UP TO 33kV

ELECTRICAL INSULATION TESTING OF HV EQUIPMENT UP TO 33kV 1. SCOPE This document details PowerSystems requirements for electrical testing of HV Equipment up to and including 33kV. 2. ISSUE RECORD This is a Reference document. The current version of Controlled

More information

GHS Flood Final Report CTA Architects Engineers March 31, 2011

GHS Flood Final Report CTA Architects Engineers March 31, 2011 GHS Flood Final Report CTA Architects Engineers March 31, 2011 INTRODUCTION: Glacier High School underwent extensive flooding due to a broken frozen fire sprinkler joint of the ceiling in the Small Conference

More information

Fire Performance Standard

Fire Performance Standard Fire Performance Standard At present, in cable industry, Fire Retardant, Low Smoke Halogen Free (LSZH), Low Smoke Fume (LSF) and Fire Resistant cables are all described as Fire survival Cables. Flame Retardant

More information

Electrical safety and you

Electrical safety and you Electrical safety and you A brief guide Introduction Electricity can kill or severely injure people and cause damage to property. Every year many accidents at work involving electric shock or burns are

More information

Homeowner Information Guide Electrical Safety. British Columbia Safety Authority

Homeowner Information Guide Electrical Safety. British Columbia Safety Authority Homeowner Information Guide Electrical Safety British Columbia Safety Authority The following information should be carefully reviewed before performing any electrical work. The information contained in

More information

Evaluating Water-Damaged Electrical Equipment

Evaluating Water-Damaged Electrical Equipment Evaluating Water-Damaged Electrical Equipment 1 USE OF THIS PUBLICATION This publication provides information on how to evaluate electrical equipment that has been exposed to water through flooding, fire

More information

4. REQUEST FOR ELECTRIC SERVICE. 4.1 General Service Information

4. REQUEST FOR ELECTRIC SERVICE. 4.1 General Service Information 4. REQUEST FOR ELECTRIC SERVICE To establish an electric service, temporary or permanent, contact UI s Customer Care Center by calling: 1-800-722-5584 (7:00 a.m. 7:00 p.m., Monday Friday and 7:00 AM to

More information

UNIVERSITY OF LEICESTER ESTATES & FACILITIES MANAGEMENT DIVISION ASBESTOS MANAGEMENT PLAN

UNIVERSITY OF LEICESTER ESTATES & FACILITIES MANAGEMENT DIVISION ASBESTOS MANAGEMENT PLAN UNIVERSITY OF LEICESTER ESTATES & FACILITIES MANAGEMENT DIVISION ASBESTOS MANAGEMENT PLAN Revision Date Nature of Revision Prepared by Approved by 0.2 Jul 2013 Initial draft for comment Jon Fahie 0.3 Sep

More information

Report on Sanctuary/Chancel Crawl Space Inspection. St. John in The Wilderness, 2896 Old Lakeshore Road Bright s Grove. Project No.

Report on Sanctuary/Chancel Crawl Space Inspection. St. John in The Wilderness, 2896 Old Lakeshore Road Bright s Grove. Project No. Report on Sanctuary/Chancel Crawl Space Inspection St. John in The Wilderness, 2896 Old Lakeshore Road Bright s Grove Project No. E112056 1. Background St. John in the Wilderness (SJITW) is considering

More information

Evaluating Water-Damaged Electrical Equipment

Evaluating Water-Damaged Electrical Equipment Evaluating Water-Damaged Electrical www.nema.org Evaluating Water-Damaged Electrical 1 USE OF THIS PUBLICATION This publication provides information on how to evaluate electrical equipment that has been

More information

Electric Service Guide for Residential Construction

Electric Service Guide for Residential Construction Electric Service Guide for Residential Construction TABLE OF CONTENTS Contacting KCP&L... 2 Existing Home Remodeling or Additions... 2 Building a New Home... 3 KCP&L Services at a Glance... 4 Current Transformers...

More information

LEAD FREE FIREX. Interlock Armored Cables TECK90 and MC Industrial Cables. w w w. n e x a n s e n e r g y. c o m

LEAD FREE FIREX. Interlock Armored Cables TECK90 and MC Industrial Cables. w w w. n e x a n s e n e r g y. c o m FIREX Interlock Armored Cables TECK90 and MC Industrial Cables LEAD FREE O V E R 1 8 0 Y E A R S O F E X P E R I E N C E 866-663-9267 w w w. n e x a n s e n e r g y. c o m Interlock Armored Cables Introduction....2

More information

National Transportation Safety Board Washington, DC 20594

National Transportation Safety Board Washington, DC 20594 National Transportation Safety Board Washington, DC 20594 Safety Recommendation Mr. Jack Requa Interim General Manager and Chief Executive Officer Washington Metropolitan Area Transit Authority 600 5th

More information

Mould Mould A Basic Guide

Mould Mould A Basic Guide Mould A Basic Guide Summary Mould is a fact of life. Moulds will grow practically everywhere people live and work. Mould is recognized as an occupational hazard for indoor workers as well as outdoor workers

More information

Axial and Radial Leaded Multilayer Ceramic Capacitors for Automotive Applications Class 1 and Class 2, 50 V DC, 100 V DC and 200 V DC

Axial and Radial Leaded Multilayer Ceramic Capacitors for Automotive Applications Class 1 and Class 2, 50 V DC, 100 V DC and 200 V DC Axial and Radial Leaded Multilayer Ceramic Capacitors for Automotive Applications Class 1 and Class 2, 5 V DC, 1 V DC and 2 V DC DESIGNING For more than 2 years Vitramon has supported the automotive industry

More information

Building Electrical Infrastructure

Building Electrical Infrastructure Building Electrical Infrastructure Industrial & Commercial Connections, Industrial / Urban Residential Development, Asset Relocation, Street Lighting Our Company Our vision is to combine electrical engineering

More information

CABLE TRENCH INSTALLATION GUIDE

CABLE TRENCH INSTALLATION GUIDE 1.0 INDEX 1.0 INDEX 2.0 PURPOSE 3.0 GENERAL INFORMATION 4.0 PLANNING INFORMATION 5.0 CREW INFORMATION 6.0 CONTRACTOR INFORMATION 7.0 PRECASTED/ POURED-IN-PLACE TRENCH DRAWINGS 2.0 PURPOSE This standard

More information

GUIDE TO THE MAINTENANCE, INSPECTION AND TESTING OF PORTABLE EQUIPMENT (ELECTRICAL APPLIANCES AND TOOLS) IN THE WORKPLACE

GUIDE TO THE MAINTENANCE, INSPECTION AND TESTING OF PORTABLE EQUIPMENT (ELECTRICAL APPLIANCES AND TOOLS) IN THE WORKPLACE GUIDE TO THE MAINTENANCE, INSPECTION AND TESTING OF PORTABLE EQUIPMENT (ELECTRICAL APPLIANCES AND TOOLS) IN THE WORKPLACE ET 215:2008 ELECTRO-TECHNICAL COUNCIL OF IRELAND 2008 Page 1 of 6 Published by

More information

Addressing Fleet Management Needs With EWIS Risk Assessment Technologies

Addressing Fleet Management Needs With EWIS Risk Assessment Technologies Addressing Fleet Management Needs With EWIS Risk Assessment Technologies Lectromec January 2012 SUMMARY: This document provides a brief overview of Lectromec s process for addressing the maintenance and

More information

CONSTRUCTION STANDARD ELECTRIC OPERATIONS ORGANIZATION

CONSTRUCTION STANDARD ELECTRIC OPERATIONS ORGANIZATION Page 1 of 11 ****This Standard Supercedes BECo CS2.13-2.3 & ComElectric OH Construction Manual, System Grounding Section, drawings CGND, GRDSUM, and C2**** 1.0 Bill of Materials GROUNDING AND BONDING POLE-MOUNTED

More information

Construction Safety and Health Newsletter Protecting your most valuable resource your workers.

Construction Safety and Health Newsletter Protecting your most valuable resource your workers. Construction Safety and Health Newsletter Protecting your most valuable resource your workers. Issue 2 2 nd Quarter 2010 In this issue: Safety Discussion Electrical Safety Large Loss Review Electrocution

More information

DIVISION 26 - ELECTRICAL SECTION 26 05 20 CABLES FOR INSTRUMENTATION

DIVISION 26 - ELECTRICAL SECTION 26 05 20 CABLES FOR INSTRUMENTATION DIVISION 26 - ELECTRICAL PART 1 - GENERAL 1.01 SUMMARY A. Section Includes 1. Instrumentation Cables 1.02 SUBMITTALS A. Submit in accordance with requirements of Section 01 33 00. B. Product Data: Submit

More information

KNOW YOUR OPTIONS: 230 KV POWER CABLES

KNOW YOUR OPTIONS: 230 KV POWER CABLES KNOW YOUR OPTIONS: 230 KV POWER CABLES 71 CONDUCTOR MATERIAL AND SIZE Conductor material is a matter of both customer preference and required current carrying capacity At 230 kv, copper is most common

More information

When power interruptions happen.

When power interruptions happen. When power interruptions happen. We know it s never a good time to have your power go out, so we work all year pruning trees and investing in our system to cut down on problems before they start. Outage

More information

Code of Practice Electricity transmission and distribution asset management. February 2009

Code of Practice Electricity transmission and distribution asset management. February 2009 Code of Practice Electricity transmission and distribution asset management February 2009 CONTENTS 1 PREFACE...4 2 APPLICATION AND OBJECTIVES...5 3 SCOPE...6 4 DEFINITIONS...7 5 DESIGN AND CONSTRUCTION...11

More information

Earthing Guidance Notes

Earthing Guidance Notes Central Networks Earthing Manual Section E2 Earthing Guidance Notes Version: 2 Date of Issue: September 2007 Author: Nigel Johnson Job Title: Earthing Specialist Approver: John Simpson Job Title: Head

More information