Saturation Diving System Components Equipment List



Similar documents
B-1 Buildings & Service Maintenance

Repairs: who s responsible?

Topics of the Presentation

CUBICLE SYSTEMS LTD. CI/SfB 74 X IPS. Pre-plumbed Wall Duct Access Panel System

ANNEX 4 - IG Rate Comparison TECHNICAL COMPARISON OF CONTRACT TERMS T&T BISSO

To: All Shipowners, Ship Managers, Ship Masters and Classification Societies

POSEIDON ISLA TRAWLERS 1490

Cooling system components, removing and installing

SANITARY & WASTE WATER PUMPING SYSTEMS. Now you can install kitchen, bathroom, laundry and commercial facilities almost anywhere.

DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS

Engineered Solutions

Confined Space Entry Procedure Worksheet

WARRANTY BOOKLET. Commercial Water Heaters. Register online at

ECOCIAT. Domestic hot water heat recovery unit

INSTALLATION INSTRUCTIONS

tidesmarine Smart Seal Temperature Alarm System Generation II Installation Instructions Starboard side cable

E. Fowler & Sons Ltd.

section 5 machine guarding and lockout

The Yachtmans Choice...

301.7D. Mini Hydraulic Excavator

Waste Oil Handling, Spill Containment & Lighting

FOGA ApS. Arctic Hunter Multipurpose/support vessel

JUBILEE TECHNICAL TRAINING CENTRE TAKORADI POLYTECHNIC 2015 TRAINING PROGRAMMES

ELECTRICAL WIRING (R.H. DRIVE VEHICLES)

Installation Instructions for Alarm Module Kit A043F059

ECHM Recommendations for Safety in multiplace medical hyperbaric chambers

TRUCK MOUNTED KNUCKLE BOOM HYDRAULIC CRANE PROPOSAL

Visage. Digital. Digital diverter. Installation guide. Visage Digital diverter installation instructions Page 1

Service Packages & Pricing

Please also see 10 golden rules for correct Saniflo installation on

TRUCK MOUNTED KNUCKLE BOOM HYDRAULIC CRANE PROPOSAL

Capital Expenditure. The common definition of capital expenditure is

Design and manufacture of subsea and topside composite cables and connectors

E-gas Instant Gas Water Heaters

Work Order History Report

Heating, Ventilation, Air Conditioning and Refrigeration (HVACR)

TRUCK MOUNTED KNUCKLE BOOM HYDRAULIC CRANE PROPOSAL

Competency Framework for Marine Engineer Class 6. Competency Framework for Marine Engineer Class 6

Gazeley. Where You and Your Horses Safety Comes First. Coachbuilders Ltd. Designed and Manufactured in Newmarket, Suffolk, Great Britain

PBX Series Quick Fit Connector Bimetallic Steam Traps

Volkswagen Jetta, Golf, GTI 1999, 2000 Brake System 47 Brakes - Hydraulic Components (Page GR-47)

understanding medium frequency induction melting furnace and its components

Safety Flash. IMCA Safety Flash 18/13 December Fatality During Lifting Operations

National Competency Based Skill Training Refrigeration and Air-conditioning Mechanic Logbook

RACE TRANSPORTER TRAILERS RACE PROFESSIONAL

API Marine. BMS Presentation. Ballast Measurement Systems

The Engine Department

Integrated Custom Systems

TANKLESS WATER HEATER INSTALLATION DIAGRAMS

Troubleshooting Guide for Jacks Down LED Lights

CO 2. fire extinguishing systems

Lebanon Fire Department Lebanon Engine 512 Check Sheet

Fire Protection Program Of Chashma Nuclear Power Generating Station Pakistan Atomic Energy Commission 5/28/2015 1

Appendix 3H A/V and Video Conferencing Standard

UNDERWATER ENGINEERING SERVICES. Visit Us Online At Part of the ATR Group

Rail Canvas, folding top Rear panel Stip in window, left dto. right

Air Vantage 500 Kubota

Turnkey Projects, Conversions, Restorations & Property Management. Marsalforn - Gozo APARTMENT FINISHING EXCLUSIVE PACKAGE

Property Services. Maintainable Assets Description Hierarchy. Revision 4.3a

COMITÉ EUROPÉEN DES ASSURANCES

EXPORT w w w. k r a n m a n. c o m

Flood Rescue Emergency Services First Responders Coast Guard Police

DANGER DANGER. General Information. Safety Is Your Responsibility. Ordering Parts. Contact Information

creating progress for the future

Table of Contents. Division 2 Site Work Site Preparation Site Demolition Tree Protection Excavation, Trenching, and Backfilling for Utilities

Asking Price: N/A Final Price: N/A OROPS BUCKET AUXILIARY HYDRAULICS GENERAL APPEARANCE. Good. Good

S/Y SEEWIND VAN DER STADT SEAL 36

Dacia Sandero and Sandero Stepway Accessories Range

SITE ACCOMODATION BUILDINGS, ABLUTION BLOCKS, CONTAINERS AND PORTABLE COMPLEXES

SPARE PARTS EXPLODED VIEW GAS WALL BOILERS Model GENUS PREMIUM FS CUENOD. R EN - Edition 01-26/10/2009

Engineers Edge, LLC PDH & Professional Training

Procurement Specification for a High Security Lift Arm Barrier (HSLAB) EB950 CR Armstrong High Security Lift Arm Barrier

2010 APPLICATION REFERENCE GUIDE

Experience Our Innovation

INSTALLATION INSTRUCTIONS

THE BASICS DOOR ENTRY AND ACCESS CONTROL SYSTEMS. Intercoms R Us Ltd 2013 (c)

2015 Malpelo Expedition 7 Diving Days

Nominal Life Expectancy for Building Components

Fire Protection Systems, Appliances and Compressed Gas Cylinders Periodic Maintenance, Inspection and Testing

AIR COMPRESSORS come with an inflating pistol and gauge for tyre inflation as well as additional accessories for use around the home.

INSTALLATION INSTRUCTIONS Fan Coil Replacement Coil Kit EBX & EBXX

Federal Wage System Job Grading Standard for Powered Support Systems Mechanic, Table of Contents

DESIGN STANDARDS SECTION

Total Solutions Providers for Fire & Security Systems

Oxygen & Nitrogen. Oxygen & Nitrogen Service Catalog. Parts & Complete Systems

FACILITY FIRE PREVENTION AND EMERGENCY PREPAREDNESS INSPECTION CHECKLIST

FFI. Advances in Medium and Low Voltage Power Distribution ESS Metron Expo and Technical Seminars. Presented By: Greg Pelster & Robert Schmid

How to report a repair

Rules for Classification and Construction Additional Rules and Guidelines 3 Machinery Installations

INTRODUCTION INDUSTRIAL INSTALLATIONS AND ERECTIONS QUALITY THAT EXCELS

REGISTRATION EXAMINATION, JUNE 2009 PLUMBING QUESTION AND ANSWER BOOKLET. Time allowed THREE hours

Method Statements. Debenham House, 8 Addison Road, London, W1J 8DJ Debenham House 8 Addison Road Holland Park W14 8DJ.

Guidance Notes For Provision Of Water Expansion For 10 & 15 Litre Unvented Hot Water Heaters

REGISTRATION OF INTEREST

ILLUSTRATED PARTS LIST

Facility Support Services

Transcription:

Marine Consultants & Specialist Brokers Saturation Diving System Components Equipment List Item No: Description Quantity 1 SDC (Bell) Fitting Out Mechanical Outfit Materials ( Valves, Fittings, pipework etc..) 1 Mechanical Outfit External (Labour) 1 Viewports 3 SDC Insulation / Floatation ( supply only) 1 Gas System G Size Onboard Gas Bottles 300 Bar 9 O2 Buffer Bottle 1 Plumbing / Pipework / Panels 1 Mara Diver Gas Panel 1 Onboard Gas Regulators Tescom 44-4013-E28-002 3 02 Analyser (PP02 Hyperbaric Analiyser) 1 CO2 Scrubbers Normal & Emergency (DH21) 2 Bibs Scotts Single Hose 4 Lung Powered Scrubbers Passive CP21600 3 Electrical System Battery Pack 1 Oil Filled Electrical Junction box External 1 Electrical Penetrators 3 Viking External Lights c/w Yoke 4 External TV Camera 1 Internal Electrical Junction Box 1 Hat Lights Divex 3 LP 20 Lights c/w 1 Meter Pigtails 2 Heater (DH21) 1 Communications Internal Radio 1 Emergency Though Water Comms 1 Bell Locating Device Transponder 1 SP Phone c/w Call Generator 1 Bell Equipment Cassion Guage 0-300 msw 2 Fibron Divers Umbilicals x 70m c/w Jupiter Connections 2 Fibron Bellmans Umbilical x 75m 1 UltraJewel 601 Reclaim Helmets 2 Specifications given in good faith but without guarantee. pg. 1

KMB 28 Bandmask 1 Bell Survival Kits 3 Drager Test Kit 1 Bell Tool Kit 1 Bailout Cylindres & Backpack X 3 3 1st Stage Reg & Bailout Whip (Posiedon) 3 Dive Harness 3 Diver Recovery Hoist 1 Pneumatic Safety Interlock 7 2 LARS c/w Umbilical and Lift Wires Winch Lloyds Classified 12 Tonne Man Riding 1 Bell Main Wire 400m @ AUD 76/mtr 1 Winch 8 Tonne Man Riding / Secondary Bell Recovery Lloyds Class 1 800 m Non Rotating SWR 16 mm (Guid Wire) 1 Hyd Umbilical Winch Constant Tension Lloyds Class 1 Braided Main Bell Umbilical @ 360 /m 1 HPU's for winches 1 Hydraulic Console including local and pilot remote control 1 Design & Fabricate HRC Launch system - Lloyds Class 1 3 DDC 1 (9 Man Twin Lock Chamber) Viewports 3 Mechanical Outfitting Materials ( Valves, pipework, Fittings) 1 Electrical Outfitting Materilas ( Cable, Cable Tray, Connectors) 1 Chamber Gas System PPO 2 Analysers 2 Bibs Scotts Twin Hose 14 Bibs, BPR Divex VM-1402-38A-XX 3 Chamber Electrical System Inernal Cable tray Wiring etc 1 Electrical Penetrators 4 Scrubber Emergency CES BH500 3 Roof Lights LP 20 c/w 1mtr pigtail 5 Bunk Lights LP 20 c/w 1mtr pigtail, switched 9 Chamber Enviromental Control Unit Chamber Conditioning ( HCU/3/6) main lock 1 Chamber Conditioning ( HCU3/4) entry lock 2 Chamber Communications Chamber Comms Box 2 Sound Powered Phone c/w call generator 2 Camera Static Low Light 2 Chamber fitted equipment Caisson Guage 0-320m 2 Fire Extinguisher Hy-Fex 7.5 Ltr 2 Interlocked Toilet & Hand Basin, Stainless Steel 1 Sanitary Holding Tank 1 Specifications given in good faith but without guarantee. pg. 2

Shower 1 Bedding (fireproof) 9 Mattresses ( Fire Proof ) 9 Temp/Humidity Guage 2 6 DDC 2 (6 Man Twin Lock Chamber) Viewports 3 Mechanical Outfitting Materials ( Valves, pipework, Fittings) 1 Electrical Outfitting Materilas ( Cable, Cable Tray, Connectors) 1 Chamber Gas System PPO 2 Analysers 2 Bibs Scotts Twin Hose 11 Bibs, BPR Divex VM-1402-38A-XX 2 Chamber Electrical System Inernal Cable tray Wiring etc 1 Electrical Penetrators 4 Scrubber Emergency (UTS Unit) 3 Roof Lights LP 20 c/w 1mtr pigtail 5 Bunk Lights LP 20 c/w 1mtr pigtail, switched 6 Chamber Enviromental Control Unit Chamber Conditioning (HCU 3/6) 1 Chamber Conditioning Unit HCU 3/4 1 Plumbing, Pipework, Valves 1 Chamber Communications Chamber Comms Box 2 Sound Powered Phone c/w call generator 2 Camera Static Low Light 2 Chamber fitted equipment Bunks, Seats 7 Caisson Guage 0-220 msw ( need 0-320m ) 2 Fire Extinguisher Hy-Fex 7.5 Ltr 2 Toilet & Hand Basin, Stainless Steel 1 Sanitary Holding Tank 1 Shower 1 Bedding (fireproof) 6 Mattresses ( Fire Proof ) 6 Temp/Humidity Guage 2 7 12 Man Single Lock HRC Viewports 2 Mechanical Outfit Materials ( Valves, Fittings, Tubing etc..) 1 Electrical Outfit Materials ( Cable, connectors etc..) 1 Chamber Gas System 9 x G Size Onboard Gas Bottles ( 200 Bar ) ( 300 Bar? ) 12 PPO 2 Analysers 2 Bibs Scotts Twin Hose 13 Bibs, BPR Divex VM-1402-38A-XX 2 Chamber Electrical System Emergency Battery 72 Hours Operations 1 Specifications given in good faith but without guarantee. pg. 3

Inernal Cable tray Wiring etc 1 Electrical Penetrators 4 Scrubber Emergency CES BH500 3 Roof Lights LP 20 c/w 1mtr pigtail 3 Bunk Lights LP 20 c/w 1mtr pigtail, switched 3 Chamber Enviromental Control Unit Chamber Coooling unit and HCU3/6 Conditioning unit 1 Chamber Communications Chamber Comms Box 2 Sound Powered Phone c/w call generator 2 Camera Static Low Light 2 Strobe, radar reflector & EPIRB 1 Chamber fitted equipment Saftey harness etc 12 Caisson Guage 0-320m 2 Fire Extinguisher Hy-Fex 7.5 Ltr 2 Rally style Seating 12 Temp/Humidity Guage 2 Lung Powered Scrubbers 13 Survival Suits, ( Thin Bear Suit ) 13 Dedicated Lifting & towing Gear 1 9 Dive Control Mechanical oufit including panel frames 1 Electrical outfit including LIMS, DP Alarms, Transformers for SDC) 1 Dive Control Gas Panels. Depth gauges 5 3 Diver Control Panel Complete, 1 02 analysers 3 C02 analysers 3 Dive Control Communications. Air radios 1 Heliox Unscramblers 2 VHF Radio & Arial/Transciever 1 TV Monitors 3 Video/DVD Recorders 2 Diver Video System 1 Deck Video System 2 19 Inch Electrical Rack 1 Black Box recorder 1 Dive Control fitted equipment Supervisors Smoke Mask with comms 1 High/Low Hot Water Alarms 1 Push Button Knife Switch, Welding/Cutting 1 10 Saturation Control Fabricate Container 1 Mechanical oufit including panel frames 1 Electrical outfit including transformers, swithc panels and cabling 1 Specifications given in good faith but without guarantee. pg. 4

Saturation Control Gas Panels.. 1 Chamber Gas Control Panel ( DDC 1 ) 1 Chamber Gas Control Panels ( DDC 2 ) 1 HRC/Chamber 3 Gas Control Panel ( HRC/DDC 3 ) 1 Bell Trunking Gas Control Panel 1 Gas Distribution & Mixing Panel 1 O2 Chamber Analyser 3 CO2 Chamber Analyser 3 Saturation Control Electrical Panels.. Chamber TV Monitor Rack 5 Chamber Communications Panel 3 Hyperbaric First Aid Kit 1 Oxy Viva 1 B.A Masks 2 Head Sets With Mike 3 Diver Entertainment System 1 Environment Control Machinery and Gas Recovery 11 System Dyfog Water Deluge System - Lloyds Approved 1 Main Electircal Distribution Board IP56 1 Electrical outfitting materials 1 3 Diver Hot Water Unit, Electric 2 CMU 02 plus Life support units 3 CEC-02 Environmental Life Support Controller Package 5 PWS-01 Kinergetics Potable Water Skid 1 Gasmizer 3 Divers Reclaim ( Airdriven ) 1 Gas Transfer panels for onboard gas storage 4 Corblin Refurbished Gas Transfer Compressors 2 Haskel Gas Booster Package 1 12 HRC Support Container 10' Air Conditioned c/w Lifting Points + Slings 1 Air Conditioner 1 HRC Control Panel 1 Communication Radio/Panel 1 TV Monitors x 2 2 Emergency HRC Umbilical 1 O2 Analyser- Analox 1 CO2 Analyser - Analox 1 Environmental Control System 1 13 Divers Apparel / Equipment 70m divers excursion umbilical (spare) c/w Jupitor TV Connector 1 Hat Mounted Video Camera 1 Survival suit & L/P Scrubber 1 Hot water suits c/w boots, gloves, Various Sizes 15 Ultrajewel 601 -reclaim helmet 1 KMB 28B Bandmask 1 Bibs Scott Twin Hose 2 Specifications given in good faith but without guarantee. pg. 5

BIBS Scott Single Hose 2 O2 Analysers Analox 2 Bailout Cylinder & Backpac 2 1st Stage Reg & Bailout Whip ( Posieden ) 3 Dive Harness 3 A.R vest 4 System Charging whips 6 O2 Cleaning Bath, Multi Metres, Meggers, Tong Testers. Lot System Plant & Equipment Tool Chest, 1 Regulators for Deck Quads 4 Specifications given in good faith but without guarantee. pg. 6