1 Oil storage tank manufacturers EFS 5000 BUNDED WITH SECURITY CABINET

2 EFS 1200 DOMESTIC capacity: 1200 litres dimensions: length 1780mm width 550mm height 1250mm finish: 2 coats bitumen on bottom 2 coats primer We supply and fit our domestic tanks including oil transfer and removal of old tank. Pictured above is the standard domestic tank. Existing cylindrical tanks can easily be replaced with one of our rectangular designs. We also stock larger tanks and can manufacture tanks to suit individual requirements. We are happy to give advice on all aspects of fuel storage and dispensing systems.

3 EFS 1400 BUNDED (STANDARD) capacity: 1400 litres dimensions: length 1250mm width 1250mm height 1250mm The primary tank is contained within its own enclosed bunded area with a capacity greater than 110%.This tank can be supported on existing block plinths, a steel stand or at ground level with skids for ground clearance and fork truck use, dipstick and sockets for lube oil use if required. Existing cylindrical tanks can easily be replaced with one of our rectangular designs. We supply and fit our oil storage tanks including oil transfer and removal and decommissioning of old tanks. We are happy to give advice on all aspects of fuel storage and dispensing systems.

4 EFS 1400 BUNDED & HOSE PACK + SECURITY CABINET capacity: 1400 litres dimensions: length 1250mm width 1250mm height 1250mm The primary tank is contained within its own enclosed bunded area with a capacity greater than 110%.This tank can be supported on existing block plinths or a steel stand, it is also fitted with skids for ground clearance and fork truck use. Also fitted are lifting lugs, dipstick, hose pack and lockable cabinet.

5 EFS 1400 BUNDED & ELECTRIC PUMP + SECURITY CABINET capacity: 1400 litres dimensions: length 1250mm width 1250mm height 1250mm The primary tank is contained within its own enclosed bunded area with a capacity greater than 110%.This tank is fitted with electric pump and flow meter. It is also fitted with skids for ground clearance and fork truck use. Also fitted are lifting lugs, dipstick, and lockable cabinet.

6 EFS 3000 BUNDED (STANDARD) capacity: 3000 litres dimensions: length 1500mm width 1500mm height 1500mm The primary tank is contained within its own enclosed bunded area with a capacity greater than 110%.This tank can be supported on existing block plinths, a steel stand or at ground level with skids for ground clearance and fork truck use, dipstick and sockets for lube oil use if required. Existing cylindrical tanks can easily be replaced with one of our rectangular designs. We supply and fit our oil storage tanks including oil transfer and removal and decommissioning of old tanks. We are happy to give advice on all aspects of fuel storage and dispensing systems.

7 EFS 3000 BUNDED & HOSE PACK + SECURITY CABINET capacity: 3000 litres dimensions: length 1500mm width 1500mm height 1500mm The primary tank is contained within its own enclosed bunded area with a capacity greater than 110%.This tank can be supported on existing block plinths or a steel stand and is fitted with skids for ground clearance and fork truck use. Also fitted are lifting lugs, dipstick, hose pack and lockable cabinet.

8 EFS 3000 BUNDED + SECURITY CABINET capacity: 3000 litres dimensions: length 1500mm width 1500mm height 1500mm The primary tank is contained within its own bunded area, with a capacity greater than 110%. This tank is fitted with an electric pump and flow meter. It is also fitted with skids for ground clearance and fork truck use. Also fitted are lifting lugs, a dipstick and a lockable cabinet.

9 EFS 3000 BUNDED + SECURITY CABINET FOR ELECTRIC PUMP capacity: 3000 litres dimensions: length 1500mm width 1500mm height 1500mm The primary tank is contained within its own bunded area, with a capacity greater than 110%. This tank is fitted with an electric pump and flow meter. It is also fitted with skids for ground clearance and fork truck use. Also fitted are lifting lugs, a dipstick and a lockable cabinet.

10 EFS 5000 BUNDED (STANDARD) capacity: 5000 litres dimensions: length 3000mm width 1500mm height 1500mm The primary tank is contained within its own enclosed bunded area with a capacity greater than 110%. This versatile design can be placed on existing solid block plinths (to supply a boiler or generator) a steel stand or at ground level and can also be fitted with a security cabinet, hose pack or electric pump. Existing cylindrical tanks can easily be replaced with one of our rectangular designs. We supply and fit our oil storage tanks including oil transfer and removal and decommissioning of old tanks. We are happy to give advice on all aspects of fuel storage and dispensing systems.

11 EFS 9000 BUNDED (STANDARD) capacity: 9000 litres dimensions: length 3660mm width 1850mm height 1850mm The primary tank is contained within its own enclosed bunded area with a capacity greater than 110%. This tank can be placed at ground level and can be fitted with a security cabinet, hose pack or electric pump. Existing cylindrical tanks can easily be replaced with one of our rectangular designs. We supply and fit our oil storage tanks including oil transfer and removal and decommissioning of old tanks. We are happy to give advice on all aspects of fuel storage and dispensing systems.

12 EFS 9000 BUNDED & ROLLER SHUTTER CABINET capacity: 9000 litres dimensions: length 3660mm width 1850mm height 1850mm The primary tank is contained within its own enclosed bunded area with a capacity greater than 110%. This tank can be placed at ground level and can be fitted with a security cabinet, hose pack or electric pump. It can also be fitted with a Bund Alarm and Anti-Overfill System. Existing cylindrical tanks can easily be replaced with one of our rectangular designs. We supply and fit our oil storage tanks including oil transfer and removal and decommissioning of old tanks. We are happy to give advice on all aspects of fuel storage and dispensing systems.

13 EFS 9000 BUNDED + SECURITY CABINET capacity: 9000 litres dimensions: length 3660mm width 1850mm height 1850mm The primary tank is contained within its own enclosed bunded area with a capacity greater than 110%. This tank can be placed at ground level and can be fitted with a security cabinet, hose pack or electric pump. It can also be fitted with a Bund Alarm and Anti- Overfill System. Existing cylindrical tanks can easily be replaced with one of our rectangular designs. We supply and fit our oil storage tanks including oil transfer and removal and decommissioning of old tanks. We are happy to give advice on all aspects of fuel storage and dispensing systems.

14 EFS 9000 BUNDED GENERATOR FEEDER + SECURITY CABINET capacity: 9000 litres dimensions: length 3660mm width 1850mm height 1850mm The primary tank is contained within its own enclosed bunded area with a capacity greater than 110%. This tank can be placed at ground level and can be fitted with a security cabinet. It can also be fitted with a Bund Alarm and Anti- Overfill System. Existing cylindrical tanks can easily be replaced with one of our rectangular designs. We supply and fit our oil storage tanks including oil transfer and removal and decommissioning of old tanks. We are happy to give advice on all aspects of fuel storage and dispensing systems.

15 EFS BUNDED (STANDARD) capacity: litres dimensions: length 6200mm width 2500mm height 1850mm The primary tank is contained within its own enclosed bunded area with a capacity greater than 110%. This tank can be placed at ground level and can be fitted with a security cabinet & electric pump. Existing cylindrical tanks can easily be replaced with one of our rectangular designs. We supply and fit our oil storage tanks including oil transfer and removal and decommissioning of old tanks. We are happy to give advice on all aspects of fuel storage and dispensing systems.

16 EFS 1000 BUNDED & BAFFLED GENERATOR FEEDER & TRANSPORTER capacity: 1000 litres dimensions: length 2000mm width 1000mm height 1400mm These tanks are specially designed to feed generators and are fitted with baffles for safe transportation of oil from site to site. The primary tank is contained within its own enclosed bunded area with a capacity greater than 110%. All fittings, fill-line, vent, and sight gauge are enclosed inside the catchment area to prevent contamination. Supplied with lifting lugs and fork pockets these tanks can be connected to a generator with all fittings securely locked inside.

17 EFS 1600 BUNDED & BAFFLED GENERATOR FEEDER & TRANSPORTER capacity: 1600 litres dimensions: length 2000mm width 1000mm height 1400mm These tanks are specially designed to feed generators and are fitted with baffles for safe transportation of oil from site to site. The primary tank is contained within its own enclosed bunded area with a capacity greater than 110%. All fittings, fill-line, vent, and sight gauge are enclosed inside the security cabinet. Supplied with lifting lugs and fork pockets these tanks can be connected to a generator with all fittings securely locked inside.

18 EFS 2700 BUNDED & BAFFLED GENERATOR FEEDER & TRANSPORTER capacity: 2700 litres dimensions: length 2500mm width 1250mm height 1700mm These tanks are specially designed to feed generators and are fitted with baffles for safe transportation of oil from site to site. The primary tank is contained within its own enclosed bunded area with a capacity greater than 110%. All fittings, fill-line, vent, and sight gauge are enclosed inside the catchment area to prevent contamination. Supplied with lifting lugs and fork pockets these tanks can be connected to a generator with all fittings securely locked inside.

19 EFS 7000 BUNDED & BAFFLED FUEL TRANSPORTER WITH PUMP AND SECURITY CABINET capacity: 7000 litres dimensions: length 2500mm width 2500mm height 1250mm These tanks are specially designed for fuel transporters. They are fitted with twist locks for safety during transport. The primary tank is contained within its own enclosed bunded area with a capacity greater than 110%. All fittings, fill-line, pump and gauge are enclosed inside a secure cabinet.

20 EFS 9000 BUNDED & BAFFLED FUEL TRANSPORTER WITH PUMP AND ROLLER SHUTTER CABINET (MILITARY) capacity: 9000 litres dimensions: length 3660mm width 1850mm height 1850mm These tanks are specially designed for the Irish Military as fuel transporters. They were fitted with twist locks for safety during transport. The tanks were mounted on flats racks. The primary tank is contained within its own enclosed bunded area with a capacity greater than 110%. All fittings, fill-line, pump and gauge are enclosed inside a secure roller shutter cabinet.

21 Tank accessories CUBE 70 PUMP FILL LINE, DIGITAL CONTENTS GUAGE AND BUND ALARM Pump delivers 70 litres per minute. The bund alarm alerts you if the tank leaks into the bund.

22 Tank accessories CUBE 70 PUMP & TANK ALARM Pump delivers 70 litres per minute. The bund alarm alerts you if the tank leaks into the bund.

23 Tank accessories DRIP TRAY Catches drips and spillages from tanks or generators.

24 Tank accessories OVERFILL LIMITER VALVE When tank reaches near capactiy during filling, this value slows pumping down to prevent over-filling.

25 Tank accessories DIGITAL CONTENTS GAUGE This gauge can be callibrated to give an accurate contents reading.

26 Tank accessories TANK ALARM This can be set to high-level, low-level, and bund alarm.

Waste Oil Handling, Spill Containment & Lighting

Waste Oil Handling, Spill Containment & Lighting 58 Waste Oil Handling, Spill Containment & Lighting 372000 SAMOA Mobile Waste Oil Drainer & Extractor Drains and/or extracts waste oil from cars and light commercial vehicles Drain bowl capacity of 20

More information

Spill Containment. IBC Bunds

Spill Containment. IBC Bunds IBC Bunds 1 x IBC Bund, Spill Pallet or Sump Pallet 2 1 x IBC Bund, Spill Pallet or Sump Pallet with dispensing facility 3 2 x IBC Bund, Spill Pallet or Sump Pallet 4 2 x IBC Bund, Spill Pallet or Sump

More information

PPG2. Pollution Prevention Guidelines. Above Ground Oil Storage Tanks: PPG2. 1. Introduction. 2. The storage container.

PPG2. Pollution Prevention Guidelines. Above Ground Oil Storage Tanks: PPG2. 1. Introduction. 2. The storage container. PPG2 February 2004 Environmental Alliance working together 1. Introduction Pollution Prevention Guidelines Above Ground Oil Storage Tanks: PPG2 These guidelines are intended to assist those responsible

More information

FUEL TANKS DOUBLE WALL FUEL TANKS

FUEL TANKS DOUBLE WALL FUEL TANKS FUEL TANKS DOUBLE WALL FUEL TANKS Since launching our product line over 65 years ago, Meridian has set the standard in excellence for the storage and handling industry. Meridian has continuously incorporated

More information

Cubetainer. The competition can t stack up to Snyder! Stackable Tanks, Stands and Containments

Cubetainer. The competition can t stack up to Snyder! Stackable Tanks, Stands and Containments Cubetainer The competition can t stack up to Snyder! Stackable Tanks, Stands and Containments Providing Bulk Storage Solutions for Motor Oil, Lubricants, Hydraulic Fluids, ATF, Antifreeze & DEF www.snydercubetainer.com

More information

GUERNSEY OIL INSTALLATION GUIDELINES

GUERNSEY OIL INSTALLATION GUIDELINES GUERNSEY OIL INSTALLATION GUIDELINES This guidance relates only to liquid oil. For information on the requirements for associated equipment such as the positioning of boilers and flues please refer to

More information

Fact sheet 6: for farmers

Fact sheet 6: for farmers Fact sheet 6: for farmers Fuel Oil Storage June 2013 Are you planning to substantially alter your fuel oil store, or add a new one? If so, this fact sheet will help you meet the requirements of The Water

More information

A SUPERIOR SOLUTION TO DRUM AND STEEL TANK USAGE

A SUPERIOR SOLUTION TO DRUM AND STEEL TANK USAGE A SUPERIOR SOLUTION TO DRUM AND STEEL TANK USAGE The U.L.C. Listed C142.14-03 Cubet container provides a unique solution to storage and dispensing fluids. The Cubet s logical and integrated design allows

More information

Fact sheet 6: for farmers

Fact sheet 6: for farmers Fact sheet 6: for farmers Fuel Oil Storage February 2011 Are you planning to substantially alter your fuel oil store, or add a new one? If so, this fact sheet will help you meet the requirements of The

More information

Best Practice Guide BPGCS005

Best Practice Guide BPGCS005 Best Practice Guide BPGCS005 OIL STORAGE GUIDLINES Background: Companies across all manufacturing sectors, store oil in varying quantities, typically between 5m 3 to 75m 3. Stored oil is used for a variety

More information

OIL SPILL CONTAINMENT CONTAINERS AND RACKING

OIL SPILL CONTAINMENT CONTAINERS AND RACKING www.lubecontrol.com.au OIL SPILL CONTAINMENT CONTAINERS AND RACKING Lube Control Pty Ltd Providing lubrication solutions! Unit 5/53 Norfolk Rd, Marion, SA 5043 t: (08) 8298 5563 f: (08) 8298 6253 e: info@lubecontrol.com.au

More information

TMS TANK MANAGEMENT SYSTEM

TMS TANK MANAGEMENT SYSTEM TMS TANK MANAGEMENT SYSTEM Page 1 of 9 Operating Instructions GENERAL The Tank Management System is a bespoke design to control, monitor and accommodate efficient storage and dispensing of TMS. FUNCTIONS

More information

IBC Tote Containment Sumps

IBC Tote Containment Sumps IBC Tote Containment Sumps DENIOS Provides More Models- and More Variety of IBC Totes Sumps than any other Manufacturer Painted, Galvanized, Stainless Steel, and Poly models available Models provide storage

More information

Master Catalogue I August 2011

Master Catalogue I August 2011 Master Catalogue I August 2011 Greasing Equipment Drum Pumps Hose Reels Vehicle Hoists Wheel Service Equipment Lubrication Systems 58 Waste Oil Handling, Spill Containment & Lighting 372000 SAMOA Mobile

More information

ABOVE GROUND OIL STORAGE TANKS: PPG2

ABOVE GROUND OIL STORAGE TANKS: PPG2 ABOVE GROUND OIL STORAGE TANKS: PPG2 POLLUTION PREVENTION GUIDELINES These guidelines are intended to assist those responsible for above ground oil storage tanks at sites other than oil refineries and

More information

Spill Containment. Contents

Spill Containment. Contents Contents IBC Bund, Spill Pallet or Sump Pallets 3-9 IBC Spill Containment Bund - User Healthy & Safety Instructions Spill Trays, Drum Bunds & Drum Pallets 11-18 Tank Bunds 19-21 Standard Sized Bunds 22

More information

Surface Water Drainage Products

Surface Water Drainage Products Surface Water Drainage Products Surface Water Drainage Products Reln Rain Drain 1m Lengths (Internal dimensions 100mm x 100mm) 118mm 100mm 100mm 128mm 1m 001134 001133 001200 001188 001195 001190 001143

More information

G R O U P. ISO 9001:2008 Certified

G R O U P. ISO 9001:2008 Certified If Your Fluid Storage Area Looks Like This... IFH Has a Better Solution. G R O U P Innovative Fluid Handling Group ISO 9001:2008 Certified Take the Innovative Approach: The IFH Fluid Storage and Dispensing

More information

Containment & Spillage Control

Containment & Spillage Control 1800 750 900 Dangerous Goods Cabinets High quality construction using zinc coated steel sheeting Powdercoat finish giving high resistance to splashes and spills All products designed to comply with Australian

More information

Spill Containment control it before it controls you!

Spill Containment control it before it controls you! Spill Containment control it before it controls you! CIVILQUIP LTD is a family owned and operated company providing innovative solutions for the total control of hazardous liquids for a wide range of applications

More information

Domestic heating Fuel storage tanks

Domestic heating Fuel storage tanks Domestic heating Fuel storage tanks Oil leaks Prevention and action www.west-norfolk.gov.uk Environmental Health and Housing Borough Council of King s Lynn & West Norfolk, King s Court, Chapel Street,

More information

Industrial Generator Set Accessories

Industrial Generator Set Accessories Industrial Generator Set Accessories Weather/Sound Enclosure and Subbase Fuel Tank Package Applicable to the following: 40REOZJC 50/60REOZJD 80/100/150/200REOZJF 125/180REOZJG 230-275REOZJE 300REOZJ Enclosure

More information

Spill Containment. Contents

Spill Containment. Contents Contents IBC Bund, Spill Pallet or Sump Pallets 2-14 IBC Bunds - User Healthy & Safety Instructions 15-16 Spill Trays, Drum Bunds & Drum Pallets 17-25 Tank Bunds 26-28 Standard Sized Bunds 29 Custom Built

More information

Section A SPCC Plan Implementation Checklist This section of the report addresses compliance with certain requirements of Federal Regulations 40 CFR 112. I. STATUS OF SPCC PLAN (40 CFR 112.3) YES NO A.

More information

Heavy-Duty Lube and Fuel Truck Sales Tool

Heavy-Duty Lube and Fuel Truck Sales Tool Heavy-Duty Lube and Fuel Truck Sales Tool Contact: Adrian Britt or Mike Kelley @ (678) 639-0099 33,000 lb. Lube/Fuel Truck Contact: Adrian Britt or Mike Kelley @ (678) 639-0099 Example Specification

More information

Industrial Generator Set Accessories

Industrial Generator Set Accessories Industrial Generator Set Accessories Weather/Sound Enclosure and Subbase Packages Applicable to the following models: 600-1000REOZM Kohler enclosures protect stationary generator sets from the elements,

More information

Budget Basins Modular Spill Platform Spill Containment Pallets Spill Containment Platforms

Budget Basins Modular Spill Platform Spill Containment Pallets Spill Containment Platforms Budget Basins Modular Spill Spill Containment Pallets Spill Containment s IBC Containment Units Spill Containment Sumps Outdoor Drum Storage Workstations SPILL CONTAINMENT For nearly 30 years, Eagle Manufacturing

More information

Environmental Management System Procedures

Environmental Management System Procedures Environmental Management System s Plan Title Oils and Oil Contaminated Items Delivery, Storage, Use and Disposal Ref No Op-Proc-71 Related Documents EMS-Plan-7 Op-Proc-72 EMS-F-71 EMS-F-72 Record of Revisions

More information

Spill Containers. 517 Series 3 ½ Gallons AST Spill Container. 518 Series 7 ½ Gallon AST Spill Container. 515 Series AST Remote Spill Container

Spill Containers. 517 Series 3 ½ Gallons AST Spill Container. 518 Series 7 ½ Gallon AST Spill Container. 515 Series AST Remote Spill Container Spill Containers 517 Series 3 ½ Gallons AST Spill Container Installed on aboveground storage tanks for the purpose of containing small spills and drips from the fill nozzle. 3 ½ gallon capacity. Steel

More information

Commercial Storage Tanks

Commercial Storage Tanks Commercial Storage Tanks ALL THE STORAGE CHOICES YOU NEED FOR A TOTAL HOT WATER SUPPLY SYSTEM. INNOVATION AT A GLANCE A. O. SMITH IS THE BEST CHOICE FOR COMPLETE COMMERCIAL WATER HEATING AND STORAGE SYSTEMS

More information

Spill Containment Manholes

Spill Containment Manholes Spill Containment Manholes 1-2100 Series OPW and Pomeco Spill Containment Manholes are designed to prevent spilled product from entering the soil near the fill and vapor return riser connections on underground

More information

Industrial Generator Set Accessories

Industrial Generator Set Accessories Industrial Generator Set Accessories Snow Enclosure and Subbase Fuel Tank Package Applicable to the following: 80/100/150REOZJF 125REOZJG Enclosure with Standard Subbase Fuel Tank Enclosure with State

More information

Drum Dispensing Stations

Drum Dispensing Stations Drum Dispensing Stations O Safely Dispense from 55 Gallon Drums over a Spill Compliant Sump. 1-2-and 4 drum models available Drums are securely held on racks by galvanized positioners Sump and frame constructed

More information

Midwest Industrial Tanks

Midwest Industrial Tanks FOR AGRICULTURE AND INDUSTRY Midwest Industrial Tanks Fuel & Oil Storage Solutions Midwest Industrial Tanks Is Your Source For All Of Your Fuel Storage And Fuel Transportation Needs. Our Satisfied Customers

More information

PCB STORAGE. 1) 2-drum unit (4 x 2 x 4 ) 2) 4-drum unit (4 x 4 x 4 ) 3) 8-drum unit (8 x 4 x 4 ) 4) 16-drum unit (8 x 8 x 10 )

PCB STORAGE. 1) 2-drum unit (4 x 2 x 4 ) 2) 4-drum unit (4 x 4 x 4 ) 3) 8-drum unit (8 x 4 x 4 ) 4) 16-drum unit (8 x 8 x 10 ) PCB STORAGE With the exception of utilities, very few PCB owners are choosing to store their PCB wastes on site. The practice of on-site PCB storage was commonplace before Swan Hills opened up in 1996

More information

ENGINEERED DRAWINGS FOR PETROLEUM STORAGE TANKS

ENGINEERED DRAWINGS FOR PETROLEUM STORAGE TANKS Facility Name: ENGINEERED DRAWINGS FOR PETROLEUM STORAGE TANKS The following is intended to be used as a guideline for information required to appear on engineered drawings involving petroleum storage

More information

Bulk System Gallery. Bulk Storage Systems. OIL SAFE Bulk Storage Systems can be configured or customized to suit your application and budget.

Bulk System Gallery. Bulk Storage Systems. OIL SAFE Bulk Storage Systems can be configured or customized to suit your application and budget. Bulk System Gallery OIL SAFE Bulk Storage Systems can be configured or customized to suit your application and budget. If you don t see a bulk storage solution that meets your lubricant management challenges

More information

Bulk Storage the OIL SAFE Way. Three System Types. Establish Best Practice

Bulk Storage the OIL SAFE Way. Three System Types. Establish Best Practice Bulk Storage the OIL SAFE Way OIL SAFE Bulk Systems are the most feature rich and highest quality lubricant storage and dispensing systems available. Fully Modular and ships ASSEMBLED Three System Types

More information

If you cause pollution or allow it to occur, you may be committing a criminal offence.

If you cause pollution or allow it to occur, you may be committing a criminal offence. PPG2 April 2010 Environment Alliance - working together Pollution Prevention Guideline Above Ground Oil Storage Tanks: PPG2 These guidelines are produced by the Environment Agency for England and Wales,

More information

SPECIALIST RENTAL PROVIDER HEATING & HOT WATER PACKAGES

SPECIALIST RENTAL PROVIDER HEATING & HOT WATER PACKAGES SPECIALIST RENTAL PROVIDER HEATING & HOT WATER PACKAGES Electric, IDF, Gas & Oil Fired Technology Heating Capacity 2.0-2,000kW ICS Cool Energy Hire Division The hire division of ICS Cool Energy is your

More information

Electric Flow Boiler

Electric Flow Boiler Electric Flow Boiler EHC offer the most comprehensive range of electric boilers in the market and with our wealth of knowledge and technical expertise we have designed the Slim Jim Electric Flow Boiler

More information

BLADE S-MAX Cabinet for Blade Server

BLADE S-MAX Cabinet for Blade Server Cabinet for Blade Server 1 2 Overview Material specification Corner verticals: 1.5 mm steel End frames: 1.5 mm steel Panel mounts: 2.0 mm steel Panel mount supports: 1.5 mm steel Side panels, door and

More information

SPILL CONTAINMENT PALLETS

SPILL CONTAINMENT PALLETS SPI CONTAINMENT PAETS According to the regulations the storage of lubricant or fuel drums in industrial or workshop environments requires suitable containers which can collect the fluids in case of eventual

More information

Used Fluid Handling Portable Used-Oil Gravity Drains

Used Fluid Handling Portable Used-Oil Gravity Drains Portable Used-Oil Gravity Drains Choose the fluid handling equipment that fits your needs. Traditional Drain: the traditional method for handling used fluids allows gravity to drain fluids from vehicle(s)

More information

Morrison Bros. Co. General Product Specifications

Morrison Bros. Co. General Product Specifications Morrison Bros. Co. General Product Specifications Tank Mounted Spillbox The spill containment device is manufactured to contain spills and drips that may occur at the fill point on aboveground storage

More information

367 000 Suction assembly for 1.000 l IBC and 205 l drums 1.060 mm suction tube. 367 003 Suction assembly for tanks 1.600 mm suction tube.

367 000 Suction assembly for 1.000 l IBC and 205 l drums 1.060 mm suction tube. 367 003 Suction assembly for tanks 1.600 mm suction tube. PUMPMASTER 2 accessories, other MOBILE oil dispensers PumpMaster 2 Accessories 01 OIL PUMPS 360 1 360 120 367 000 367 011 369 910 360 1 Wall bracket 360 120 Floor bracket 360 001 Bung adaptors 2" (M) connection

More information

DIRECTIVE 055: STORAGE REQUIREMENTS FOR THE UPSTREAM PETROLEUM INDUSTRY. August 2012

DIRECTIVE 055: STORAGE REQUIREMENTS FOR THE UPSTREAM PETROLEUM INDUSTRY. August 2012 DIRECTIVE 055: STORAGE REQUIREMENTS FOR THE UPSTREAM PETROLEUM INDUSTRY August 2012 SECTION 2 The storage requirements in Directive 055 apply to upstream petroleum facilities, well sites, and pipelines

More information

Civil Engineering Sector Labour-Management Health and Safety Committee

Civil Engineering Sector Labour-Management Health and Safety Committee PROCEDURE FOR THE STORAGE AND HANDLING OF FUEL ON CONSTRUCTION SITES Civil Engineering Sector Labour-Management Health and Safety Committee July 2008 PROCEDURE FOR THE STORAGE AND HANDLING OF FUEL ON CONSTRUCTION

More information

MAINE DEPARTMENT OF ENVIRONMENTAL PROTECTION

MAINE DEPARTMENT OF ENVIRONMENTAL PROTECTION Oxford Hills Bus Garage 36 Brown St, Norway, ME Oil Storage Inspection 2/20/14 CONDITIONS OBSERVED Underground Oil Storage: 12,000 gallon underground oil storage tank (split 10,000 gallon diesel/2,000

More information

BULK SYSTEMS CATALOG. The Leader in Visual Lubrication Systems. Industrial Filtration Specialists. www.filtramax.com/oilsafe 1-888-924-6233

BULK SYSTEMS CATALOG. The Leader in Visual Lubrication Systems. Industrial Filtration Specialists. www.filtramax.com/oilsafe 1-888-924-6233 BULK SYSTEMS CATALOG The Leader in Visual Lubrication Systems TM Industrial Filtration Specialists www.filtramax.com/oilsafe 1-888-924-6233 QuoTe request enter your preferred model part number or choose

More information

SAMPLE TEST QUESTIONS STEAMFITTER/PIPEFITTER - ITA WEBSITE

SAMPLE TEST QUESTIONS STEAMFITTER/PIPEFITTER - ITA WEBSITE 1 Which tool is used to correct internal hi-low when preparing a 4-in. steel pipe for welding? A. 4-in. grinder with cutting disc. B. Mini-grinder with flapper disc. C. Pencil grinder with cone stone.

More information

CABINET & ENCLOSURE WWW.LINKBASIC.COM STANDARD FEATURES MATERIALS APPLICATION N C B C A B I N E T P/N:NCB

CABINET & ENCLOSURE WWW.LINKBASIC.COM STANDARD FEATURES MATERIALS APPLICATION N C B C A B I N E T P/N:NCB STANDARD Comply with ANSI/EIARS-30-D, DIN9; PART, IEC97-, DIN9; PART7, GB/T307.-9 standard. Compatible with metric ETSI and 9 inch international standard. FEATURES Exquisite design with precise craftsmanship

More information

Industrial Generator Set Accessories

Industrial Generator Set Accessories Industrial Generator Set Accessories Weather/Sound and Subbase Package Applicable to the following: 700-1000REOZDE 750-1000REOZMD Weather Standard Features D Internal-mounted, exhaust silencer with rain

More information

DIESEL FUEL CONDITIONING

DIESEL FUEL CONDITIONING COD FILTRATION DIESEL FUEL CONDITIONING REMOVE WATER & PARTICLES TO EXTEND FUEL INJECTOR LIFE & INCREASE COMBUSTION ENGINE FUEL EFFICIENCY Remove free water to saturation point with high single pass efficiency

More information

CSD WATER REMOVAL FILTERS FOR DIESEL

CSD WATER REMOVAL FILTERS FOR DIESEL CSD CSD WATER REMOVAL FILTERS FOR DIESEL Remove water to extend fuel injector life & increase combustion fuel efficiency Remove free water to saturation point with high single pass efficienc (achieve

More information

MOBILE FIRE - RESCUE DEPARTMENT FIRE CODE ADMINISTRATION

MOBILE FIRE - RESCUE DEPARTMENT FIRE CODE ADMINISTRATION MOBILE FIRE - RESCUE DEPARTMENT FIRE CODE ADMINISTRATION Fire Pump Plan Review 2009 International Fire Code and NFPA 20 Date of Review / / BLD201 - Project Address: Project Name: Contractor s Business

More information

DRUM ROLLER. FAR-1, Article No. B69-6300-A DRUM CART FOR 200 LITER STEEL DRUMS. Model FK 1029-1 FK 1029-3 FK 1029-2 FK 1029-4

DRUM ROLLER. FAR-1, Article No. B69-6300-A DRUM CART FOR 200 LITER STEEL DRUMS. Model FK 1029-1 FK 1029-3 FK 1029-2 FK 1029-4 DRUM ROLLER Suitable for drums up to 200 liter capacity Made from fire-galvanized sheet steel ø 610 mm, with 4 polyamide swiveling castors ø 75 mm Model FAR-1: closed version with welded leak-proof base,

More information

We have the experience

We have the experience We have the experience EST. 1977 Worldwide Generator, Electrical & Mechanical Installation Contractors 1 Aidan Strain has been in business since 1977, initially as commercial, industrial and domestic electrical

More information

Product Catalogue (updated Feb. 2010)

Product Catalogue (updated Feb. 2010) Product Catalogue (updated Feb. 2010) 315 BROCK RD GREENSVILLE ON L9H 5H7 PHONE: 905-628-0766 FAX: 905-628-8277 www.efcomltd.com info@efcomltd.com 1 Table of Contents Tool Boxes... 3 Cylinder Enclosures

More information

fuelstore the Power Behind

fuelstore the Power Behind fuelstore the Power Behind - Complete Oil and Fuel Storage Solutions Titan Environmental is the clear market leader in oil, fuel and lubricant storage. Reliable, innovative and safe, Titan s range of tanks

More information

The 26 200 kva RAnge

The 26 200 kva RAnge The 26 200 kva Range The new 26 200 kva range...designed to Deliver More. We understand the unique needs of generating set customers around the world. Forty years experience combined with the latest technology

More information

P 602. This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

P 602. This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001. This generator set has been designed to meet ISO 88 regulation. This generator set is manufactured in facilities certified to ISO 900. This generator set is available with CE certification. Enclosed product

More information

OPTIONAL FEATURES 30 WWW.MACGEN.CO.UK

OPTIONAL FEATURES 30 WWW.MACGEN.CO.UK OPTIONAL FEATURES 30 OPTIONAL FEATURES. Mobile Trailer Units The MacGen range of generator units are available on mobile road-tow chassis up to 00kVA. Fully galvanised and constructed from folded steel,

More information

VEHICLE SERVICE DISPENSING SYSTEMS

VEHICLE SERVICE DISPENSING SYSTEMS VEHICLE SERVICE DISPENSING SYSTEMS Lincoln s LFC Family of Fluid Inventory Control and Management Systems Finally a complete offering of systems to meet the varying needs of vehicle service centers! Each

More information

BULK SYSTEMS CATALOG. The Leader in Visual Lubrication Systems TM. oilsafe.com. A division of Whitmore

BULK SYSTEMS CATALOG. The Leader in Visual Lubrication Systems TM. oilsafe.com. A division of Whitmore A division of Whitmore BULK SYSTEMS CATALOG The Leader in Visual Lubrication Systems TM oilsafe.com 5S A division of Whitmore ACHIEVE YOUR BEST PRACTICE LUBE ROOM Modernize your Lubricant Storage & Handling

More information

Uninterruptible Power Supply. 500 kva - 750 kva

Uninterruptible Power Supply. 500 kva - 750 kva 9 315 Uninterruptible Power Supply 500 kva - 750 kva T1 and T3 Installation Addendum 164201244-001 Rev. A ------------------------------------------------------------------------ ------------------------------------------------------------------------

More information

Number Wheeler P/N Description Set Rex P/N Notes

Number Wheeler P/N Description Set Rex P/N Notes 1 604041 Base 1 4041 2 604042 Base Cover 1 4042 3 608849 Washer (M5) 2 4 600124 Spring Washer (M5) 2 5 600329 Rd Hd Machine Screw (M5x8) 2 6 604047 Strainer 1 4047 7 600204 Rd Hd Machine Screw (M6x10)

More information

Blowdown vessels Meeting the requirements of HSE PM60

Blowdown vessels Meeting the requirements of HSE PM60 Blowdown vessels Meeting the requirements of HSE PM60 BDV60 blowdown vessels complete range of equipment for the safe disposal of boiler blowdown Boiler blowdown Steam boilers must be blown down to remove

More information

Section 8 Storage Tanks & Equipment

Section 8 Storage Tanks & Equipment Section Storage Tanks & Equipment Table of Contents Section Storage Tanks & Equipment Above Ground Horizontal Tanks... -1-4 Containment Sumps...-5 Fillrite AC & Transfer Pumps... -9-10 Fillrite Diesel

More information

Fire Pump Plan Review March 2010

Fire Pump Plan Review March 2010 Fire Pump Plan Review March 2010 Date of Review: / / Permit Number: Business/Building Name: Address of Project: Designer Name: Designer s Phone: Contractor: Contractor s Phone: Occupancy Classification:

More information

Secure your IT equipment with confidence... secure with NetClosure

Secure your IT equipment with confidence... secure with NetClosure Secure your IT equipment with confidence... secure with NetClosure SERVER CABINETS NetClosure s REM Series Server Cabinet is the ultimate solution designed and engineered for demanding data center environments.

More information

Lubricant Transfer, Storage & Dispensing

Lubricant Transfer, Storage & Dispensing Lubricant Transfer, Storage & Dispensing WHY USE OIL SAFE TRANSFER CONTAINERS? OIL SAFE - TRANSFER CONTAINERS For more than a decade, OIL SAFE has been the oil transfer manage- The color-coded range of

More information

Steel Spill Containment Pallets

Steel Spill Containment Pallets Steel Spill Containment Pallets O DENIOS steel pallets and sumps are the icons in the industry for compliant containment and long-term service. Heavy gauge steel provides the durability and security demanded

More information

OIL & GAS EQUIPMENT RENTAL SOLUTIONS. byrnerental.com

OIL & GAS EQUIPMENT RENTAL SOLUTIONS. byrnerental.com OIL & GAS EQUIPMENT RENTAL SOLUTIONS byrnerental.com BYRNE EQUIPMENT RENTAL Contents Page Byrne Equipment Rental 3 Who we are 4 Our Credentials 5 Our Products Turnkey Camp Solutions 6 Modular Buildings

More information

Unit 15: Measurement Length, Area and Volume

Unit 15: Measurement Length, Area and Volume Unit 15: Measurement Length, Area and Volume Section A: Circumference measuring the circumference of a round object. You will to show all of your working out. C 5 d where: C 5 circumference 5 3.14 d 5

More information

1.1 DIMENSIONS AND WEIGHT PAG. 2 1.2 LOAD CENTRE FOR LIFTING PAG. 2 1.3 STORAGE CONDITIONS PAG. 2

1.1 DIMENSIONS AND WEIGHT PAG. 2 1.2 LOAD CENTRE FOR LIFTING PAG. 2 1.3 STORAGE CONDITIONS PAG. 2 TRANSPORT AND INSTALLATION. DIMENSIONS AND WEIGHT PAG.. LOAD CENTRE FOR LIFTING PAG..3 STORAGE CONDITIONS PAG. STARTING. INSTALLATION PAG.. SPACE REQUIREMENTS PAG. 3.3 ELECTRIC CONNECTION PAG. 3 3 DESCRIPTION

More information

18. CARGO TROLLEYS, LIFTING TABLES, HYDRAULIC TABLE TRUCKS, HAND TROLLEYS

18. CARGO TROLLEYS, LIFTING TABLES, HYDRAULIC TABLE TRUCKS, HAND TROLLEYS 18. CARGO TROLLEYS, LIFTING TABLES, HYDRAULIC TABLE TRUCKS, HAND TROLLEYS CARGO TROLLEYS LIFTING TABLES HYDRAULIC TABLE TRUCKS HAND TROLLEYS 18 CARGO TROLLEYS CARGO TROLLEYS 1500 KG groove in the centre

More information

PaLLe t trucks Lifting carts t r g in t if L 2435 6815 6836 6856 6842

PaLLe t trucks Lifting carts t r g in t if L 2435 6815 6836 6856 6842 l i f t i n g c a r t s Lifting carts The prograe for lifting, transporting and storage From the classical forklift trolley to the machine lifter, from furniture dollies to a chassis with 24 tons load

More information

INSTALLATION INSTRUCTIONS. 6108 Air Spring Kit 2011+ Ford F250 Single Wheel 4WD 2011+ Ford F350 Dually 4WD (2011 F350 Single Wheel 4WD use p/n 6113)

INSTALLATION INSTRUCTIONS. 6108 Air Spring Kit 2011+ Ford F250 Single Wheel 4WD 2011+ Ford F350 Dually 4WD (2011 F350 Single Wheel 4WD use p/n 6113) INSTALLATION INSTRUCTIONS 6108 Air Spring Kit 2011+ Ford F250 Single Wheel 4WD 2011+ Ford F350 Dually 4WD (2011 F350 Single Wheel 4WD use p/n 6113) Thank you for purchasing a quality Hellwig Product. PLEASE

More information

Lift- and transport truck HTW 50/100 Standard model

Lift- and transport truck HTW 50/100 Standard model Lift- and transport truck HTW 50/100 Standard model The lift- and transport truck has a rugged, torsion-resistant frame structure, steel powder-coated (grey RAL 7035) with smoothly running, integrated

More information

Fluid Monitoring and Inventory Management

Fluid Monitoring and Inventory Management SECTION FOUR Fluid Monitoring and Inventory Management Introduction Alemite meets your fluid monitoring and inventory management needs with its Accu-Guard systems and its Bigview Tank Monitor. These systems

More information

ReadyLift (Part# 66-5075) Strut Extension, Installation Instructions Toyota Tundra New Body Style 2WD & 4WD

ReadyLift (Part# 66-5075) Strut Extension, Installation Instructions Toyota Tundra New Body Style 2WD & 4WD SAFETY WARNING: recommends this system be installed by a professional technician. In addition to these instructions, professional knowledge of disassembly/ reassembly procedures and post installation checks

More information

CAT NEXT GENERATION DIESEL GENERATOR SETS. C15 ACERT and C18 ACERT 410-700 kva / 365-600 ekw

CAT NEXT GENERATION DIESEL GENERATOR SETS. C15 ACERT and C18 ACERT 410-700 kva / 365-600 ekw CAT NEXT GENERATION DIESEL GENERATOR SETS C15 ACERT and C18 ACERT 410-700 kva / 365-600 ekw THE NEXT GENERATION CAT DIESEL GENERATOR SET FEATURES SEVERAL KEY DESIGN AND PERFORMANCE ENHANCEMENTS TO ITS

More information

INSTALLATION INSTRUCTIONS. 6111 Air Spring Kit 2011+ Ford F250/F-350 Single Wheel 2WD 2011+ Ford F350 Dually 2WD IMPORTANT NOTES

INSTALLATION INSTRUCTIONS. 6111 Air Spring Kit 2011+ Ford F250/F-350 Single Wheel 2WD 2011+ Ford F350 Dually 2WD IMPORTANT NOTES INSTALLATION INSTRUCTIONS 6111 Air Spring Kit 2011+ Ford F250/F-350 Single Wheel 2WD 2011+ Ford F350 Dually 2WD Thank you for purchasing a quality Hellwig Product. PLEASE READ THIS INSTRUCTION SHEET COMPLETELY

More information

Cat Fusion Coupler System Wheel Loaders 938, 950, 962, 966, 972 H and K-series

Cat Fusion Coupler System Wheel Loaders 938, 950, 962, 966, 972 H and K-series Cat Fusion Coupler System Wheel Loaders 938, 950, 962, 966, 972 H and K-series Features Improved Machine Performance Unsurpassed Durability Increased Visibility Wide Range of Job Site Solutions Benefits

More information

DRAFT REVISED 2015. Musts For USTs DRAFT. Printed on Recycled Paper. Updated June 2015

DRAFT REVISED 2015. Musts For USTs DRAFT. Printed on Recycled Paper. Updated June 2015 DRAFT REVISED 2015 Musts For USTs DRAFT Printed on Recycled Paper EPA wrote this booklet for owners and operators of underground storage tanks (USTs). This booklet describes the 2015 revised federal UST

More information

ENGINE POWERED 5-10t. ~ r"." - )5 F-ii'ii""i;~ CPCD50 CPCD60 CPCD70 CPCD80 CPCD100

ENGINE POWERED 5-10t. ~ r. - )5 F-ii'iii;~ CPCD50 CPCD60 CPCD70 CPCD80 CPCD100 HELl ENGINE POWERED 5-10t I; ~ r"." d- - )5 F-ii'ii""i;~ CPCD50 CPCD60 CPCD70 CPCD80 CPCD100 STANDARD SPECIFICATION Manufacturer HUI HELl ca., LTD. Model CPCD50 CPCD60 CPCD70 CPCD80 CPCD100 Load Capacity

More information

Underground Storage Tanks

Underground Storage Tanks Underground Storage Tanks An Informational and Guidance Document for the University Community. Please contact Yale Environmental Health and Safety for latest Regulatory Requirements. A typical UST installation

More information

Installation and Service Instructions. Neutralization System Part no. 7441823 Grünbeck part no. 410480

Installation and Service Instructions. Neutralization System Part no. 7441823 Grünbeck part no. 410480 Installation and Service Instructions for use by heating contractors Neutralization System Part no. 7441823 Grünbeck part no. 410480 Safety and Installation Requirements Please ensure that these instructions

More information

Auto Boom Breakaway High Floatation Tires (20 x 10 x 8.0) Adjustable Hitch Height 1 Year Sprayer Warranty Manual Boom Section Control

Auto Boom Breakaway High Floatation Tires (20 x 10 x 8.0) Adjustable Hitch Height 1 Year Sprayer Warranty Manual Boom Section Control F/S ATV Maxi 18 Maxi s Walking Tandem Axles Axles Adjust for Row Spacing 4 HP Honda Engine with 22.5 GPM Centrifugal Pump Designed to be Pulled by a Larger ATV or Small Utility Tractor Add Spot Spraying

More information

Range Tribune HE Solar Unvented Direct and Indirect Cylinders

Range Tribune HE Solar Unvented Direct and Indirect Cylinders Range Tribune HE Solar Unvented Direct and Indirect Cylinders Range Tribune HE Solar cylinders have been designed specifically with Solar applications in mind and are based on the highly successful Range

More information

GCSE Revision Notes Mathematics. Volume and Cylinders

GCSE Revision Notes Mathematics. Volume and Cylinders GCSE Revision Notes Mathematics Volume and Cylinders irevise.com 2014. All revision notes have been produced by mockness ltd for irevise.com. Email: info@irevise.com Copyrighted material. All rights reserved;

More information

CITY OF WASHINGTON SPILL PREVENTION, CONTROL AND COUNTERMEASURE PLAN

CITY OF WASHINGTON SPILL PREVENTION, CONTROL AND COUNTERMEASURE PLAN CITY OF WASHINGTON SPILL PREVENTION, CONTROL AND COUNTERMEASURE PLAN Adopted October 5, 2009 Table of Contents Chapter Description Page 1 Facility Descriptions... 3 1.1 Municipal Power Plant, 1001 Park

More information

304.5. Mini Hydraulic Excavator

304.5. Mini Hydraulic Excavator 304.5 Mini Hydraulic Excavator Cat 3024 Naturally Aspirated Diesel Engine Flywheel Power 28 kw 38 hp Operating Weight: With cab 4595 kg 10130 lb With canopy 4475 kg 9866 lb 304.5 Mini Hydraulic Excavator

More information

oil care Looking after your heating oil in the south east

oil care Looking after your heating oil in the south east oil care Looking after your heating oil in the south east We are the Environment Agency. It s our job to look after your environment and make it a better place for you, and for future generations. Your

More information

QUICK BUILD DEMOUNTABLE CONTAINERS & WAREHOUSES. Construct the Quick-Build Container in under 5 minutes!

QUICK BUILD DEMOUNTABLE CONTAINERS & WAREHOUSES. Construct the Quick-Build Container in under 5 minutes! DEMOUNTABLE CONTAINERS & WAREHOUSES Construct the Quick-Build Container in under 5 minutes! Quick-Build Warehouse, assembly in just a few hours... Quick & Easy! Available to order NOW! build in 15 mins!

More information

WASTE OIL DRAINERS 99. Waste oil drainers

WASTE OIL DRAINERS 99. Waste oil drainers WASTE OIL DRAINERS 99 8 100 WASTE OIL DRAINERS wheel-mounted for drums 20/220 kg Art. 42050 (20/60 kg) Art. 42000 (180/220 kg) Art. 42050 Waste oil drainer for tanks or drums composed of: art. 80050 Trolley

More information

Chemical Feed System Operation and Design Considerations

Chemical Feed System Operation and Design Considerations PNWS AWWA MAY 7, 2014 EUGENE, OREGON Chemical Feed System Operation and Design Considerations Kevin Batridge Lake Oswego Tigard Water Partnership Austin Peters MWH Global Chemical Delivery and Storage

More information

Heavy Duty Industrial Air Compressors

Heavy Duty Industrial Air Compressors HEAVY DUTY SERIES - VERTICAL TANK MOUNTED All units mounted on air receivers rated at 200 psi and CRN approved for Canada. All units may be ordered with magnetic starter (Starter supplied loose). All units

More information

Procurement Specification for a High Security Lift Arm Barrier (HSLAB) EB950 CR Armstrong High Security Lift Arm Barrier

Procurement Specification for a High Security Lift Arm Barrier (HSLAB) EB950 CR Armstrong High Security Lift Arm Barrier Procurement Specification for a High Security Lift Arm Barrier (HSLAB) EB950 CR Armstrong High Security Lift Arm Barrier A. Requirement This document is to be used to specify the physical and operational

More information