Security. Alarm central unit. Ref.-No. KNX Alarm central unit EAM 4000



Similar documents
868 MHz. VdS. Original size Aluminium. The first ARGUS Smoke Detector System with VdS* approval. * Association of. Polar white.

Combi B Alarm box. Mounting instructions

ABB Stotz-Kontakt GmbH ABB safe&smart Project planning of security systems

ABB i-bus KNX Security Terminals MT/U , MT/S M and M Product Manual

Product and functional description

BURGLAR ALARM SYSTEMS BURGLAR ALARM SYSTEMS BURGLAR ALARM SYSTEM EURO ALARM WIRELESS BURGLAR ALARM SYSTEM OASIS

HAM841K ALARM CONTROL PANEL FOR COMMERCIAL AND RESIDENTIAL SECURITY SYSTEMS

Shunt lock function 3066

How To Use A Power Supply On A Powerline 2.2 (Ai)

Wireless Alarm system s manual

TS93 EMR T/PT/TDE. Surface applied door closer

HERZ-Thermal Actuators

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

DALI RC BASIC SO. Control unit Operating instructions

Intruder alarm. Pro 21 TM /Solfà TM. Installation and operating instructions N0064EG2/00


ABB i-bus KNX Security Solutions with KNX Security Terminal Product Information

Shunt lock function 3066 Operator Instructions

Electromagnetic Locking

Overview. Components of an alarm system Technology behind the equipment Communication Platforms Industry Terminology False Alarm Tips DSC products

Simon XTi Installation Guide

(68.52) X. June 2000 Supercedes February xenex CONVENTIONAL FIRE DETECTION & ALARM SYSTEM. we business differently

Operating instructions IV / 2007

L-LAS-TB-CL serie. laser light curtains for inline measuring tasks

GSM ALARM SYSTEM USER MANUAL

Two-way communication, keep checking the commnunication between the panel and accessories, make sure the system safer.

SECTION DETECTION AND ALARM

ACS-30-EU-EMDR-10-MOD

Operating instructions Mechatronic flow sensor. SBY33x /06 03/2011

Material test chamber with mechanical convection

DC-8706K Auto Dial Alarm System

PROFESSIONAL HOME ALARM SYSTEM. Important! Please read these instructions carefully.

New XUY roller sensors

Car Alarm Series 2 B 2 Buttons

CSP Combined Series. Telephone Door Entry. with. Proximity Keyfob Access

2013 Wireless Video Intercom INSTALLATION GUIDE

Fire Alarm Control Panel. Family. Operating Manual

500r+ Installation and User Guide

Inwall 4 Input / 4 Output Module

Product and Applications Description. Application Programs. Example of Operation. GAMMA instabus Technical Product-Information.

TX GSM SMS Auto-dial Alarm System. Installation and User Manual

ABLOY DOOR AUTOMATICS Easy access for all types of swing doors

Wireless Home Security Alarm System AM 500

FLEET MANAGEMENT & CAR SECURITY SYSTEM GPRS/GPS

GSM ALARM SYSTEM GCM 8

Tilt switches N3 / N4... MEMS technology, one or two axis. Use. Options. + long lifetime and highly reliability due to mechanism-free MEMS technology

basicdim DGC Compact control module

Business/Home GSM Alarm System. Installation and User Manual

CM705B - Universal Expander Module CM707B - Plug On Zone Expander Security Systems

561-MB100. Intruder Alarm Control Panel. Maximum security for all eventualities. Features

Heating Controller. Building Technologies HVAC Products

ACTIVE 5 ENGINEERING MANUAL

Quick Connect. quick - simple - efficient.

3. Security System Requirements

HCR3.2/.. Chipcard reader HOTEL SOLUTION

SMART SENSOR COLLECTION

GSM WIRELESS DIGITAL ALARM SYSTEM USER GUIDE. Please read it carefully before installation and operation

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Alarm over IP. IRIS Touch Home Installation Manual. Version 1.0 ENGLISH. Now certified and compliant with EN50131, EN50136 Security Grade 4 ATS6

Wireless alarm system with voice dialer

TAC I/NETTM. Intrusion Alarm System


WaterCress - Critical Infrastructure Protection

Safety technique. Emergency stop module BO 5988 safemaster

QFP910. Water detector. Building Technologies. CE1N2732en. Synco living

MAKING MODERN LIVING POSSIBLE. living connect. Installation and User Guide. Danfoss heating

SEISMIC VELOCITY TRANSDUCER T1-40

How To Read A Pipe From A Sensor

Model: DC-A2IO Advanced HVAC Controller

TCR easy Plus Alarm. Operating Instructions

CB200W Water Leak Detection Panel Application Guide

Power Supply and Indicator Unit Type Fig. 1 Type Mounting and Operating Instructions EB 9539 EN

Wireless Alarm System. Window/Door Sensor. User s Manual. Choice ALERT. Control all Sensors & accessories from one location

S100. GSM House Alarm System.

AUDIO VIDEO INTERCOM SYSTEMS SECURITY & SAFETY AT YOUR FINGER TIPS AUDIO VIDEO INTERCOM SYSTEMS

Home alarm system. User s manual. Profile To better understand this product, please read the user s manual carefully before using.

WIRELESS ALARM KIT INSTRUCTION MANUAL COMPLETE ALARM SYSTEM FOR HOME OR BUSINESS. Model Number: IT214054

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

RRV934. Multi-controller. Synco living

Light scene push button 8gang comfort flush-mounted xx

Short Form Catalogue. Alarm Systems. Reliable Supervision and Control

RI-215A Operator s Manual. Part Number: RK Revision 0 Released: 10/3/05

FIREDEX Conventional Fire Panels

Advanced Fencing and Security Technologies Ltd

Understanding Alarm Systems

Remote Monitoring and REC 501 Control Unit Product Guide

Page 1. Description

Residential & Commercial Alarm Systems by Gross Security, LLC

Measurement. SITRANS F US Inline. Transmitter FUS080/FUE080 4/219

Total Protection Alarm System

PASSIVE INFRARED INTRUSION DETECTOR PASSIVE INFRAROOD DETECTOR DETECTEUR D INTRUSION PASSIF INFRAROUGE

Intrusion. IC60 security meets design. Answers for infrastructure.

Features. Display. Measurements. Intelligent. Accuracy. Models. Installation DEIF A/S. Multi-instrument D

XIGHTOR DOOR ENTRY SYSTEM. Company Name company address line 1 company address line 2

EVC40 EMERGENCY VOICE COMMUNICATION SYSTEM

HM-W536 Install Guide

PSU-U-24V/AC-6A/10/FTA-TR-MC PSAC 0624

INSTALLATION GUIDE. Card Reader & Controller with KIM Swipe Reader for Solitaire 850 / 950 / 850L Learnlok PK2930

FVSU REPAIR & UPGRADE FIBER OPTIC SECTION FIRE ALARM SYSTEM CONNECTIVITY

Transcription:

Security Alarm Central Unit 3 4 Technical KNX Alarm central unit EAM 4000 ETS-product family: Alarm system Product type: Alarm central unit The alarm central unit is a modern alarm system using the KNX system. Detailed knowledge about planning, designing and commissioning of alarm systems are absolutely required. The alarm central unit is a modern intruder alarm system using the KNX system for the transmission of information. It keeps an object under surveillance and detects and signals intrusion attempts. The system is no substitute for any mechanical safeguarding devices which prevent intrusion into your property. You can use the alarm central unit as a comfortable extension for any existing KNX installations. The alarm central unit has been designed in compliance with VdS (German Association of the Damage/Loss Insurers) guidelines. The functionality of the device is dependent on the parameters of the software application. To install and configurate the software it requires at least the ETS.a version. By using the KNX the additional wiring and cabling effort of a separate alarm system can be reduced to a minimum. This is achieved by using sensors, i.e. movement detector not just purely for lighting control or alarm systems. data Input supplying Voltage: 30 V AC, ± 0 %, 50/60 HZ Power consumption: max. 4 W Current secondary: max. 50 ma; during changing process approx. 00 ma Fuses: F = T 00 ma (5 V supply of central unit) F = T 00 ma ( V power supply) F3 = T 00 ma (supply for telephone dialer) F4 = T 3.5 A (main fuse 30 V) F5 = T 3.5 A (protection of accumulator) Output voltage for alarm device: SELV V DC, ± V Max. capacity of outputs: Telephone dialer: 00 ma V supply 00 ma Sirens/flash in total.6 A (electronic overload protection) Capacity of relay: SELV V (AC/DC), 5 A (min. 30 ma) Storage battery: V /. Ah Charge voltage: approx. 3.4 V Charge current: approx. 50 ma Supply KNX: SELV V 3 V Power consumption: max. 40 mw Connection KNX: KNX connection block mains: screw terminals up to.5 mm Spare accumulator: V/, Ah, ref.-no. DAS 45 4

Central Alarm Unit EAM 4000 4 Technical 5 System data Protection: IP 0 Operation temperature: 5 C... +45 C Storing temperature: 5 C... +70 C Dimension: 0 x 70 x 73 mm Weight: approx. 500 g (including accumulator) Event memory: min. 80 events per security area 40 events for each fire and alarm Length of wires: to alarm devices: 00 m at 0.8 mm diameter to telephone dialer: 00 m at 0.6 mm diameter to wired detectors: 00 m at 0.8 mm diameter to sabotage line: 600 m at 0.8 mm diameter Resistance of wired detectors: max. kohm configuration: Note: For the planning and programming of the whole system it is absolutely necessary to have the knowledge about alarm systems and the specific terminology as well as a product training on the alarm central unit. Functional features: Up to 60 sensors can be administrated and integrated in up to 4 separate safeguarding areas. All sensors are connected via the KNX to the alarm central unit. Hence, the identification and monitoring of all sensors is obtained. All events (as arming, alarm, failure) are saved with time and date in a protocol. Alarm devices (as siren, flash or telephone dialer) can be connected directly to the alarm central unit or can be controlled via KNX. The alarm central unit has an integrated floating storage battery which, in case of mains failure, guarantees a back-up time of approx. hours. The displaying and operation is done by external KNX devices like Info Display, push-buttons, etc. In one armd area several operation units can be applied. An additional local sensor input can be used to protect the location where the alarm central unit is mounted. Furthermore, a relay contact can be used to connect additional alarm devices. The alarm central unit is developed for different applications. It starts in residential buildings with the protection of the outside body (windows, doors) and the interior and ends in office buildings, whereby up to 4 different security areas can be defined and protected separately or linked together. 4

Central Alarm Unit EAM 4000 5 Alarm system configurations: Due to many different parameterisation options, the KNX alarm central unit can be used in various objects from the detached family house with outer shell and inner room safeguarding up to the office building where up to four arming areas (AA) can be safeguarded individually or in groups linked up with one another. The following list shows the basic configurations which may also be combined with one another: x inner room, x outer shell (nested)*: Detached family house, flat. (AA = outer shell, AA = inner room; AA can be armed individually or together with AA). AA AA x [ x inner room, x outer shell (nested)*]: Two-family house, house with granny flat, separate safeguarding areas (workshop with flat). AA AA AA3 AA4 Up to 4 separate areas: Shopping arcade, holiday houses, hotel/pension, trade fair/exhibition halls. Up to 4 separate areas (cascaded)**: Office/industrial building, sports hall. (AA4 only to be armed if AA to AA3 have already been armed). AA AA AA3 AA4 AA AA AA3 AA4 * nested: The subordinate area is armed together with the higher-order area. ** cascaded: The higher-order area can only be armed if the subordinate areas have already been armed. Fire and attack detectors: Regardless of the configuration of the system, the fire and attack areas are always active. If a fire or attack detector is activated, the system will immediately set off an alarm, regardless of what its state is. As a special variant, the alarm central unit can also be solely used for attack and fire. 43

Security Accessories DAS 40 DAS 40 60 Outdoor siren with flash light DAS 40 Rated voltage: V DC Protection: IP 34 Indoor siren DAS 40 Rated voltage: 0 8 V DC Protection: IP 3 TC Plus KNX analog 60 (more details please refer to pages 7/8) DAS 460 FUS 460 Automatic alarm dialer, Digital only on special request The digital automatic dialer provides a silent transmission of an alarm or malfunction to a permanent available security service. Automatic alarm dialer, Analog FUS 460 The analog automatic dialer provides a silent transmission of an alarm or malfunction. 4 alarm inputs 4 outputs to be switched via phone 44

Accessories DAS 4300 A DAS 40 Surface mounted key switch, For activating and deactivating of alarm systems Front plate material: Pressure casted aluminium Flush-mounted key switch Front plate material: Lost-wax casted aluminium (profile cylinder lock is not included!) DAS 4300 A DAS 4300 U Movement detector DAS 40 Passive infrared detection principle Detected area: 90 (volumetric) 34 double zones in 3 levels Maximum detected area approx. 5 x 5 m DAS 4370 DAS 4360 FUS 440.. Locking unit DAS 4370 Frame joint switch contact DAS 4360 Glass-break sensor, passive Magnet contact white brown FUS 445 WW FUS 440 WW FUS 440 BR 45