How To Power A Power Control On An Ip40 (Ipl) With A Power Supply (Iplug) With An Ip20 Controller (Iphones) With Power Control (Power Control) With No Antenna) With The Ip20 (Power)



Similar documents
AC-115 Compact Networked Single Door Controller. Installation and User Manual

Installation manual. Version

INSTALLATION/PROGRAMMING INSTRUCTIONS E4KP ENTRYCHECK

EMBEDDED ACCESS CONTROL Hardware Installation Guide

User Manual. Before installation and use, please read the user manual carefully.

AR-721U/721K/661U User s Guide

INSTALLATION GUIDE. Card Reader & Controller with KIM Swipe Reader for Solitaire 850 / 950 / 850L Learnlok PK2930

CM705B - Universal Expander Module CM707B - Plug On Zone Expander Security Systems

EVC40 EMERGENCY VOICE COMMUNICATION SYSTEM

User Manual GSM Alarm System. All rights reserved by Delta Security Co., Ltd

Application/Connection Examples

Digital Keypad Use s Manual

Business/Home GSM Alarm System. Installation and User Manual

The GV-I/O Box 8 Ports provides 8 inputs and 8 relay outputs, and supports both DC and AC output voltages.

* DISCLAIMER: Contents. How to Use This Guide: COMMERCIAL INSTALL GUIDE 2

EQUIPMENT SPECIFICATIONS

Advantium 2 Plus Alarm

3 Specification. Master Chip Broadcom Keys Direct-button 1. Microphone 1. Amplifier 0.5W Speaker 0.5W. Voice

BACnet Automation Interface Module (Network Version)

IP Indoor High Speed Dome. CAM-6500 series. Ver Quick Installation Guide

DORMA MODEL PS-406BB POWER SUPPLY INSTALLATION INSTRUCTIONS

Hardware Installation Guide

MAKING MODERN LIVING POSSIBLE. AK-SC255 On-Site Installation Guide DANFOSS ELECTRONIC CONTROLS & SENSORS

SDN INSTRUCTIONS 07/10, Ver 1.2. Somfy Digital Network (SDN) Installation and Programming

SCREENLOGIC INTERFACE WIRELESS CONNECTION KIT

T3 Mux M13 Multiplexer


INTELLIGENT CONTROL MODULE SA-2000-II HARDWARE MANUAL. Access Technologies International, Inc.

The GV-I/O Box 16 Ports provides 16 inputs and 16 relay outputs, and supports both DC and AC output voltages.

GPS NTP Time Server for Intranet Networks DIN RAIL Version

Ericsson W25. Mobile Networks. Quick Installation Guide

Home Security Alarm System

CSP Combined Series. Telephone Door Entry. with. Proximity Keyfob Access

PK5500 v1.1 Installation Instructions

NC-12 Modbus Application

Version Date Author Description Jpo First version Jpo FET output descriptions made clearer

KTA-223 Arduino Compatible Relay Controller

R&D Access Touch 3.1 User Manual Version 1.00 Public 1 (13) User Manual. Access Touch 3.1

DC-8706K Auto Dial Alarm System

TX GSM SMS Auto-dial Alarm System. Installation and User Manual

Wireless Router Setup Manual

HERZ-Thermal Actuators

WxGoos-1 Climate Monitor Installation Instructions Page 1. Connections. Setting an IP Address

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

INSTALLATION INSTRUCTIONS

Fire Fighter Phone System Installation Instructions

GV-AS Controller. Installation Guide

GPS NTP TIME SERVER Rack Version V2.2x

TCP/IP MODULE CA-ETHR-A INSTALLATION MANUAL

Shunt lock function 3066

TIME BOX BIOMETRIC TECHNICAL INSTRUCTIONS AND QUICK START GUIDE IT IS RECOMMENDED TO READ THIS MANUAL BEFORE OPERATING THE SYSTEM

FIREDEX Conventional Fire Panels

Integra32. Integrated Alarm Monitoring and Access Control HARDWARE MANUAL

Installation Guide. LR-HWLV-HVAC TouchPRO Wireless. System Types

Combi B Alarm box. Mounting instructions

HCS-3300/3302/3304 USB Remote Programmable Laboratory Grade Switching Mode Power Supply

GPS NTP TIME SERVER Rack Version V2

MDM192 MULTI-DROPS DIGITAL MODEM FOR PRIVATE LINE. USER GUIDE Document reference :

PROXIMITY CARD READERS C-10, C-20, C60, C70

MicroTech II McQuay Maverick II Rooftop Unit Controller BACnet Communication Module (MS/TP)

GV-AS/EV Controller. User s Manual

PRO370D 65A Mbus MID DIN rail three phase four wire energy meter. User manual Version 1.03

Technical Description. Transistor D.C. Chopper Controller Type GS 24 S

Product Manual. ABB i-bus KNX IP Interface IPS/S 2.1. Intelligent Installation Systems ABB

8 Channel Status Input Panel model SIP-8

ScreenLogic Wireless Connection Kit. Installation Guide. pool/spa control system

Network Time Accessories LED CLOCK. (for NTP Synchronization)

WIND ALARM. Wind Speed Alarm. Wind Speed. Set Point 2. Set Point 1 NEW BEDFORD, MA USA

CAUTION! THE 7I29 USES VOLTAGE AND POWER LEVELS THAT REPRESENT A HAZARD TO LIFE AND LIMB.

TEMON 8-C. Doc. N MO-0370-ING TEMPERATURE MONITOR DEVICE TYPE TEMON 8-C OPERATION MANUAL. Microener - Copyright 2010 FW 2.2 Date Rev.

Business/Home. GSM Alarm system

Outdoor-Ready Box. Hardware Manual KCM-5211E, KCM-5311E KCM-5511, KCM Ver. 2014/10/15

IPX AUTOMATIC IP NETWORK LOSS BACKUP A/B SWITCH INSTRUCTION BOOK IB

Technical data. General specifications. Indicators/operating means. 30 Hz Multiplex operation 30 Hz / n, n = number of sensors, n 5

Wireless Alarm System. Alarm Siren. User s Manual. Choice ALERT. Control all Sensors & accessories from one location

pole, 8 A Safety relay. Screw terminal. 35 mm rail (EN 60715) mounting. 2 CO (DPDT) 8/15 250/400 2, /0.65/0.

Adaptability to Enhanced Security

5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual

FSLIMRF

Table of Contents. Chapter1. Introduction Before Installation System Requirements... 1

162 CB CABLE TRACER. Filter Probe & Tone Generator INSTRUCTION MANUAL

200 Range Dialer Installation Manual. Version 1.0

PolyBot Board. User's Guide V1.11 9/20/08

Application Note - Connecting an Electricity Meter to SolarEdge Devices (Europe and APAC)

OPL BASIC. Dosing System for Professional Laundry machines. Contents

Adaptability to Enhanced Security

Short Range Wireless Switch System Handheld 8 Installation and Operations Guide

Acano solution. Acano Solution Installation Guide. Acano. January B

USB to RS-422/485 Serial Adapter

EDI Distributor Control Interface Wiring and Setup Instructions

Square D Clipsal DIN-Rail Four-Channel Auxiliary Input Unit

GLOLAB Universal Telephone Hold

VTO6xxx. IP door stations. User manual

Secure Keypads for access control

UNC500 HARDWARE MANUAL. new generation building security

ACR880 GPRS Portable Smart Card Terminal

SNMP Web Management. User s Manual For SNMP Web Card/Box

GE Wireless Devices Battery Replacement

Alarm over IP. IRIS Touch Home Installation Manual. Version 1.0 ENGLISH. Now certified and compliant with EN50131, EN50136 Security Grade 4 ATS6

ABB Drives. User s Manual. Pulse Encoder Interface Module RTAC-01

Transcription:

MODEL NUMBER: ISC910-1-0-GB-XX ISC911-5-0-GB-XX IXP20 CONTROLLER SPECIFICATIONS Working Environment Plastic Housing... Power ImproX IXP20 Controller INSTALLATION MANUAL Designed to work in an indoor (dry) environment similar to IP40. The Controller is not sealed against water. Input Voltage... 10 V DC to 30 V DC, polarity sensitive. Power Requirements (ISC910) Current (ma) Power (W) Input Voltage 12 V DC with no Antennas attached... 90 1.08 Input Voltage 24 V DC with no Antennas attached... 50 1.20 Input Voltage 12 V DC with Antennas attached... 100 1.20 Input Voltage 24 V DC with Antennas attached... 60 1.44 Power Requirements (ISC911) Current (ma) Power (W) Input Voltage 12 V DC with no Antennas attached... 140 1.68 Input Voltage 24 V DC with no Antennas attached... 65 1.56 Input Voltage 12 V DC with Antennas attached... 150 1.8 Input Voltage 24 V DC with Antennas attached... 75 1.8 Relay Power Requirements... An additional ~0.4 W per Relay in use. Real Time Clock (RTC) Backup Battery Battery Type... 1 x 3 V, CR2032, Lithium cell Battery.

Real Time Clock (RTC) Backup Battery (Continued) Battery Life... Controller Communication Ethernet Port... Terminal Communication RS485 Terminal Port Electrical Interface... 2 Years with power OFF, 5 years with Power ON, 5 Years Storage with Battery Tab in place. Standard Ethernet RJ45 connector. 10/100 Base T, half or full duplex. RS485. Baud Rate... 38 400. Data Format... Communications Protocol... Line Termination (RS485)... Reader Options Antenna Reader Ports... Relays Relay Output... Relay Contact Ratings... Operations... Digital Inputs Type... Detection Resistance Range... Protection Range... 8 data bits, no parity, 1 stop bit. ImproX Secure Communications Protocol. Provision is made for line termination. 2 Fully functional Antenna Reader Ports. 2 Independent, single-pole, double-throw (SPDT) Relays, each with NO, COM and NC contacts. 10 A at 28 V DC, 5 A at 220 V AC, 12 A at 120 V AC. 100 000 Minimum. 4 Dry-contact Digital Inputs. < 2 kohm. +15 V continuous. Blank Space ISC303-0-0-GB-01 June 2010 Page 2

NOTE: Door Lock General Figure 1: End of Line (EOL) Sensing Circuit End of Line (EOL) Sensing enables the Controller to raise an alarm when somebody tampers with the circuit (that is, cutting or shorting the wires) between DOS [1] and GROUND (GND). In other words the Controller distinguishes between tampering on the circuit, and the door being in an actual Normally Open state. By placing Resistors into the circuit between DOS [1] and GROUND (GND), the Controller s Digital Input monitors a constant resistance through the circuit. When the circuit is tampered with, the Resistors are bypassed; the Controller detects the resistance change raising an alarm. Type... Protection Range... Antenna Frequency... Antenna Read Capability... Controller Diagnostic Indicators Buzzer Volume and Tone... Display (ISC911 Only) Type... Resolution... Colour... 2 Dry-contact inputs. +15 V continuous. 125 khz. Slim Tags Omega Tags, WriTag 128, WriTag 2048 and HID 125 khz Tags. NOTE: CAUTION: HID is a registered trademark of HID Global Corporation (an ASSA ABLOY Group Brand). The IXP20 System does not support the use of HID 1346 Proxkey II Tags. Single tone, with a 3-step adjustable volume. Thin Film Transistor Liquid Crystal Display (TFT-LCD). 240 x 320 Pixels. 65 K Colour Screen. ISC303-0-0-GB-01 June 2010 Page 3

Display (Continued) Back-lighting... Status LED Power On... Upgrade Mode... Incoming RS485 Data... Outgoing RS485 Data... Digital Inputs (1-4)... Relays (1 and 2)... Enet Act (Ethernet Activity)... Enet Spd (Ethernet Speed)... Enet Lnk (Ethernet Link)... Permanently on. Continuous Red. Flashing Red (Steady). Flashing Green LED. Flashing Red LED. Continuous Green on detected contact closure. Continuous Red on activation of the Relay. Flashing Red LED. Continuous Red for 100 Mbps (Default) Off for 10 Mbps. Continuous Red on connection to network. INSTALLATION INFORMATION Accessories CAUTION: The IXP20 Controller needs a standard Ethernet cable to connect to a PC. We do NOT however supply this cable with the Controller s accessories. Find the following when unpacking the IXP20 Controller: Either an ImproX IXP20 Twin Antenna Controller with Web Interface (ISC910) supplied in a Black ABS Plastic housing. The housing consists of a Front Cover Assembly and a Mounting Plate. The Front Cover and Mounting Plate are held together with two Combi Screws (M4 x 10 mm) at the bottom of the housing. Or, an ImproX IXP20 Twin Antenna Controller with Touch Screen (ISC911) supplied in a Black ABS Plastic housing. The housing consists of a Front Cover Assembly and a Mounting Plate. The Front Cover and Mounting Plate are held together with two Combi Screws (M4 x 10 mm) at the bottom of the housing. CAUTION: NOTE: DO NOT use the Metal-oxide Varistors (25 Vrms, 500 A, 77 V max clamping) with mains power applications. Three Metal-Oxide Varistors, 25 Vrms, 500 A, 77 V max clamping. A 3 V, CR2032, Lithium cell Battery. The 3 V, CR2032 Lithium cell Battery is partially installed in all models of the IXP20 Controller. An extra Fixed Address Label. Blank Space ISC303-0-0-GB-01 June 2010 Page 4

General Remember the following when installing the IXP20 Controller: Communications Distance The RS485 communications distance between the first IXP20 Controller and the LAST ImproX unit in a cable run, MUST NOT exceed 1 km (1 090 yd). Achieve this by using good quality screened twisted 2-pair cable, with the screen EARTHED at one end. Jumper Links Long transmission lines or multiple star connections, may cause communication problems. Placing a Jumper Link across the jumper (See Figure 3 for position) in the LAST UNIT AT THE END OF THE CABLE RUN should solve the problem. Antenna Reader Distance The ideal cable distance between the IXP20 Controller and its Antenna Reader ranges between 2 m to 25 m (7 ft to 82 ft). Optimal performance is not guaranteed outside of this range. Achieve optimal performance using a good quality shielded multi-strand 3-pair twisted cable. The cable individual conductor cross-sectional area should not be less than 0.2 mm 2 (0.0003 in 2 ). Ensure that your cable specifications are similar to the following: Conductor Resistance: < 2 ohms. Capacitance, Core to Earth: < 160 pf/m. Capacitance, Core to Core: < 100 pf/m. Distance between Antenna Readers from the SAME Controller To avoid mutual interference, install the Antenna Readers alongside each other at least 150 mm (6 in) apart. Distance between Antenna Readers from DIFFERENT Controllers To avoid mutual interference, install the Antenna Readers alongside each other at least 500 mm (20 in) apart. NOTE: IXP20 Controllers can be mounted alongside each other. EARTH Connection Connect the IXP20 Controller to a good EARTH point. Using the RS485 Port, connect the EARTH Lead to the ETH Terminal. Mains EARTH can be used, but electrical noise may exist. Blank Space ISC303-0-0-GB-01 June 2010 Page 5

Arc Suppression Snubber devices are recommended for EMF Flyback and Arc Suppression when driving an inductive load with the Relay, see Figure 2. Figure 2: EMF Flyback and Arc Suppression Installing the Real Time Clock (RTC) Backup Battery CAUTION: Remove the Battery Tab for the Real Time Clock from the Battery Holder BEFORE powering up the IXP20 Controller. First Time Use 1. Ensure that power is NOT applied to the Controller. 2. Locate the removable Battery Tab at the bottom of the Controller s housing. 3. Pull the removable Battery Tab out of the Battery Holder. 4. Apply power to the Controller. Replacement NOTE: Because of the delicacy of this procedure, we recommend you contact your distributor before trying to replace the Battery. Mounting the IXP20 Controller CAUTION: Make certain that you mount the Controller on a vibration-free surface. NOTE: The IXP20 Controller can be mounted onto virtually any surface including metal. Select the mounting position of the IXP20 Controller, considering accessibility, routing of wires and visibility of the Thin Film Transistor Liquid Crystal Display (TFT-LCD) and accessibility of the Keypad. Secure the enclosure to the mounting surface, using four suitable screws and wall plugs, nuts and bolts or rivets. ISC303-0-0-GB-01 June 2010 Page 6

DIP-switch Settings NOTE: Once the DIP-switch settings are modified reset the IXP20 Controller to acknowledge the new settings. Door Lock Select DIP-switch Settings DIP-switch Position Connections 0 No special lock control. 1 Motor Lock. 2 Pulse or Repeating Lock. 3 Fail Safe or Fail Secure with Locked or Unlocked Status (Solenoid Lock). 4 Normal Lock, no Lock or Unlock Sensors, only Emergency Mode support. 5 Returns Controller to Factory Default Settings. NOTE: Return Switch 1 to the OFF position to resume normal operation. Table 1: Door Lock Select DIP-switch Settings Blank Space ISC303-0-0-GB-01 June 2010 Page 7

ELECTRICAL CONNECTIONS Key Component Positions Figure 3: Key Component Positions ISC303-0-0-GB-01 June 2010 Page 8

Connecting the IXP20 Controller Figure 4 shows a detailed electrical connection diagram for the IXP20 Controller. Figure 4: Typical IXP20 Controller Electrical Connections ISC303-0-0-GB-01 June 2010 Page 9

Figure 5: Motor Lock Connection Details ISC303-0-0-GB-01 June 2010 Page 10

Figure 6: Solenoid Lock Connection Details ISC303-0-0-GB-01 June 2010 Page 11

ADVANCED SETTINGS Restoring Factory Default Settings CAUTION: The procedures below are Controller specific. Ensure that you follow the correct procedure for your model Controller. Failure to do so results in loss of the Database. Restore the Controller s factory default settings as follows: ISC910 1. Remove the Controller s Front Cover Assembly. 2. Set the Door Lock Select DIP-switch Switch 1 to the ON position (see Table 1, row 5 for details). 3. Reset the Controller by removing and then reapplying the power source. 4. With the Controller running, set the Door Lock Select DIP-switch Switch 1 back to the OFF position (see Table 1, row 5 for details). 5. Reattach the Controller s Front Cover Assembly. ISC911 CAUTION: Ensure that you return Switch 1 of the Door Lock Select DIP-switch to the OFF position. Failure to do so automatically clears the System Database on the next restart. 1. Remove the Controller s Front Cover Assembly. 2. With power applied to the Controller, toggle switch 1 of the Door Lock Select DIPswitch ON and then OFF. 3. Complete the Action textbox, by clicking the button and selecting from the following: No Change maintains user settings. Reset Admin Password restores the administrator password to factory default (12345) without resetting the System Database. Reset System Database clears the Database, restoring it to factory default settings. 4. Click the button. 5. Click the button. 6. Reattach the Controller s Front Cover Assembly. UNIT ADDRESS INFORMATION Fixed Address Once the IXP20 Controller is installed, sketch a rough site plan. Attach the loose (additional Fixed Address Label packaged with the Controller) Fixed Address Label in the position of the Controller on the sketched site plan. When the system installation is complete and all the units are represented on the site plan by their Fixed Address Labels, file the site plan for future reference. ISC303-0-0-GB-01 June 2010 Page 12

The Fixed Address Label included with the Controller is the Fixed Address for the Controller only. In addition to the Controller Fixed Address, the IXP20 Controller reports up to two Terminal Fixed Addresses. Controller s Fixed Address: 6E XX XX XX. Reader 1 s Fixed Address: 6F XX XX XX. Reader 2 s Fixed Address: 70 XX XX XX. NOTE: Where additional Terminals connect to the Controller, extra Fixed Addresses for the respective Terminals appear during the Software s Auto- ID process. MAC Address Figure 7: Sample MAC Address Label Each IXP20 Controller is supplied with a separate MAC Address Label, much like the one shown in Figure 7, which uniquely identifies each Controller. Attach the extra loose MAC Address Label, alongside the Fixed Address Label, to the Unit Location Chart enclosed (or your sketched site plan). IP Address NOTE: All ImproX IXP20 Controllers have the same IP Address (192.168.100.1). In the absence of a DHCP server, plug each Controller into the network individually and set the static IP Address. Unit Location Chart Fixed Address Label Unique Location Description ISC303-0-0-GB-01 June 2010 Page 13

Fixed Address Label Unique Location Description ISC303-0-0-GB-01 June 2010 Page 14

Fixed Address Label Unique Location Description ISC303-0-0-GB-01 June 2010 Page 15

Fixed Address Label Unique Location Description ISC303-0-0-GB-01 June 2010 Page 16

Fixed Address Label Unique Location Description Table 2: Unit Location Chart GUARANTEE OR WARRANTY CAUTION: We reserve the right to nullify the products guarantee or warranty where you have not properly installed the Metal-oxide Varistors. This product conforms to our Guarantee or Warranty details placed on our Web Site, to read further please go to www.impro.net. USER NOTES ISC303-0-0-GB-01 June 2010 Page 17

USER NOTES ISC303-0-0-GB-01 June 2010 Page 18

USER NOTES ISC303-0-0-GB-01 June 2010 Page 19

USER NOTES This manual is applicable to the ImproX IXP20 Controller, ISC910-1-0-GB-02 and ISC911-5-0-GB-02. (The last two digits of the Impro stock code indicate the issue status of the product). ISC303-0-0-GB-01 Issue 02 Jun 2010 IXP20\Controller\English Manuals\LATEST ISSUE\ IXP20iTT-insm-en-02.docx ISC303-0-0-GB-01 June 2010 Page 20