DIVISION 7 - THERMAL AND MOISTURE PROTECTION



Similar documents
CHAPTER 7: Building Systems ROOFING SYSTEMS

SECTION STANDING SEAM METAL ROOFING

1. Adhered KEE membrane roofing system. 2. Mechanically fastened KEE membrane roofing system.

Holiday Inn Express & Suites Covington (Newton County) 1. Standing-seam metal roofing, custom fabricated.

RESIDENTIAL ROOFING & RE-ROOFING, ROOF VENTILATION AND ROOF SHEATHING REQUIREMENTS MICHIGAN RESIDENTIAL CODE 2000

Asphalt Shingle Application Requirements

CHAPTER VII. TITLE: STANDARDS FOR NEW ROOFING July 2015 CONSTRUCTION, RE-ROOFING CONSTRUCTION AND ROOFING SYSTEM GUARANTEE REQUIREMENTS

Drexel Metals Inc. DMC 100SS 16oz min. Copper Mechanical Seam Metal Roof System over Plywood

Final inspections are completed by site visit only. Access to fenced yards shall be planned.

SECTION PREFORMED METAL STANDING SEAM ROOFING

CITY OF WHITE BEAR LAKE BUILDING INSPECTION DEPARTMENT 4701 Highway 61 White Bear Lake, MN Fax: Re-Roofing: Asphalt Shingles

ROOFING APPLICATION STANDARD (RAS) No. 150 PRESCRIPTIVE BUR REQUIREMENTS

STANDARD PROCEDURES FOR INSTALLATION OF METAL ROOF SYSTEMS

SECTION PREFORMED METAL STANDING SEAM ROOFING PART 1 - GENERAL 1.1 DESCRIPTION OF WORK

Residential Roofing Guide

TARRANT COUNTY DETAIL STANDARDS

Table of Contents. I. Roof Scuttles

TITLE: MASONRY PARAPET WALLS AND FLAT ROOF REQUIREMENTS 11/1/09

VA25014B0516 VA CINCINNATI PROJECT NO INPATIENT BED TOWER ADDITION (4 TH AND 5 TH FLOORS) SECTION GYPSUM BOARD

SECTION THERMOPLASTIC MEMBRANE ROOFING

C. Remove all existing asphalt shingles, underlayment and any loose debris into contractor provided dumpsters.

Detached accessory structures that contain no conditioned floor area are exempt.

Sun Windows General Information Sun New Construction Window Installation Instructions

Quality You Can Trust Since From North America s Largest Roofing Manufacturer

Roofing Systems. There are many different systems, each with it's own special requirements and benefits. Browse through all the options below.

PREMIUM LAMINATED ASPHALT SHINGLES Dallas, TX Tuscaloosa, AL Phillipsburg, KS

City of San Diego, CWP Guidelines

If you are a web registered user of ArlingontPermits.com you may also request an inspection at:

GUIDELINE SPECIFICATIONS

INSTALLATION OF A BAY WINDOW

Building Owners Guide to a Duro-Last System!

UNIVERSITY OF WASHINGTON Facilities Services Design Guide. Architectural. Roofing. Basis of Design

ROOFS - Guidance for Repair, Maintenance and Replacement

How To Compare Roofing Material

PETERSONS WATERFRONT CONDOMINIUMS

SECTION ROOFING TILE

STANDING SEAM SHEET METAL ROOFING

Specifications. Preformed Metal Wall and Roof Panels. Alcoa Cladding Systems Manufacturing Plant 100 Industrial Boulevard Eastman, Georgia 31023

Preformed Metal Roofing and Siding

How To Repair A Boat Landing Deck With A Boat Bed

SECTION STANDING SEAM METAL ROOF

SECTION MODIFIED BITUMINOUS MEMBRANE ROOFING. A. Vapor barrier (base ply); cover board at existing roof deck.

SECTION METAL ROOF & WALL PANELS

Memtec Single Ply PVC Membrane Roofing and Waterproofing Technology. Modern Efficient Performance Cost Effective Flat Roofing Systems

Smooth cap sheet SQ $ Smooth cap sheet SQ $ Smooth cap sheet SQ $ Smooth cap sheet SQ $ 36.

City of Somersworth, New Hampshire OFFICE OF THE FINANCE DIRECTOR

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: METAL ROOF PANELS REPORT HOLDER: FIRESTONE BUILDING PRODUCTS COMPANY, LLC

How To Build A Roof Tile Deck

A. This Section includes rubberized asphalt sheet membrane waterproofing systems.

THERMAL AND MOISTURE PROTECTION WATERPROOFING

SECTION STANDING SEAM METAL ROOFING

SECTION PREFORMED METAL ROOF PANELS

!!! !!!! !!! !!! !!! !!! !!!!!!!!! Table of Contents! Section 1: Most Common Types of Flat Roofing! Section 2: Better Understand Your Flat Roof!

TABLE OF CONTENTS" SECTION 3: Comparing Standing Seam Metal to Other Metal Roofs PAGE 7"

How to repair your existing low slope flat roof.

The better way to build TM. Installation Manual. FOUNDATION SIPs & FROST WALLS SIPs

SECTION CEMENT-MORTAR LINED AND COATED STEEL PIPE

Classic Products, Inc. ClickLock Standing Seam Installation Manual

Please read the entire document before purchasing and installing any of these products

NEW ELECTRICAL SUBSTATION Building 300 SECTION ETHYLENE-PROPYLENE-DIENE-MONOMER ROOFING WORK

SECTION ALUMINUM FRAMED ENTRANCES and STOREFRONTS. System 402 Flush-Glazed Screw Spline Storefront

WESTERN COOL ROOF SYSTEMS Sustainable - Energy Efficient FLUID APPLIED REINFORCED ROOF SYSTEM

SECTION SINGLE PLY MEMBRANE ROOFING. 4. Minor repair to adjacent clay tile roofing and flashings.

EcoTouch Insulation with PureFiber Technology

APPLICATION INFORMATION FOR RESIDENTIAL ROOFING AND RESIDENTIAL ROOFING PACKET

HERITAGE WOODGATE LAMINATED ASPHALT SHINGLES Dallas, TX

We urge you to read and follow the attached installation instructions. Failure to do so may void the warranty of this garden window unit.

RB271 06/07 R807.1 RB272 06/07 R Public Hearing: Committee: AS AM D Assembly: ASF AMF DF. Proponent: Rick Davidson, City of Hopkins, MN

Rouse Life Sciences Roof Repair or Replacement SECTION

NRCA s steep-slope manual is thoroughly revised for 2013

ROOF DRAINS TABLE OF CONTENTS

ITEM THERMOPLASTIC MEMBRANE ROOFING

SECTION STANDING-SEAM METAL ROOF PANELS PART 1 - GENERAL 1.1 RELATED DOCUMENTS

Inspecting to a higher standard.

CHAPTER 6 ASPHALT ROLL ROOFING

Table of Contents. Western States Standing Seam SS675 Panel Installation, Flashings & Shop Drawing Detail Guide. Notes to Designer /Installers..

R E S I D E N T I A L H O U S I N G

ROOF INSPECTION REPORT

INSTALLATION INSTRUCTIONS for Vinyl Windows with Integral Nailing Fin (JII001)

GUIDE SPECIFICATION. Manufacturer: DECRA Roofing Systems, Inc.

THERMOTEK SELF ADHESIVE MEMBRANE +G2 OVER WOOD SYSTEM DESCRIPTION SELF ADHESIVE OVER WOOD (8YR) BS-SA/CS

September 3, Ric Boyd, Public Works Director Ketchikan Gateway Borough 344 Front St. Ketchikan, AK 99901

SINGLE FAMILY RESIDENCE HURRICANE MITIGATION APPLICATION

STANDARD REQUIREMENTS FOR BONDING OR MECHANICAL ATTACHMENT OF INSULATION PANELS AND MECHANICAL ATTACHMENT OF ANCHOR AND/OR BASE SHEETS TO SUBSTRATES

ROOF ASSEMBLIES CHAPTER 9

Roofing Systems. New Applications / Re-Roofing / Maintenance

BITUMINOUS ROOF COATINGS, CEMENTS, PRIMERS AND ADHESIVES

The Butler MR-24 Standing Seam Roof Difference. A comparison between metal roof systems

BUILT-UP ROOF COATING SMOOTH and GRANULE SURFACE SPECIFICATION

RESIDENTIAL MASONRY A BEST PRACTICES GUIDE

Mark Cramer Inspection Services, Inc.

Renovating Your Basement

H-Stud Area Separation Wall System

Window Installation Instructions

Roof Condition Analysis

HHS J.W. Peavy Center Exterior Walls Waterproofing and Roof Replacement Project WBS # H SECTION STANDING SEAM METAL ROOFING

GreenGuard Housewrap Installation Guide

NRDCA 400 GUIDELINE FOR FIELD APPLICATION of LIGHTWEIGHT INSULATING CONCRETE REROOFING/RECOVER SYSTEMS

SECTION SANITARY SEWER AND STORM DRAIN SYSTEMS

Larry Haight's Residential Roofing Co, Inc NE 95th Street Redmond, Washington Phone: (425) Fax: (425)

Transcription:

DIVISION 7 - THERMAL AND MOISTURE PROTECTION Note: This is a guide for Designers only. Contents shall not be used in lieu of specifications as part of the Designer s Contract Documents. SECTION 07 1000 WATERPROOFING 1.1 QUALITY ASSURANCE Applicators: Submit a letter from the manufacturer of waterproofing materials stating that the applicator is approved by the manufacturer for application of the waterproofing system specified. Applicator shall have a minimum of five years experience in satisfactory application of the type(s) of system(s) specified. 1.2 WARRANTY Guarantee: Guarantee membrane waterproofing for two years with the Contractor or waterproofing sub-contractor agreeing to repair or replace work which leaks or otherwise fails to perform as required due to failures of materials or workmanship. This shall include the removal and replacement of any work which conceals the membrane work. 2.1 LOCATION A. Provide membrane waterproofing at the following locations: 1. All exterior walls below-grade that enclose rooms and spaces. 2. Walls of below grade elevator pits. 3. Toilet rooms, housekeeping closets and all floors containing floor drains, except where located on slab on grade (slab on grade damp proofing is standard (6) mil reinforced polyethylene with all punctures/penetrations sealed). 4. Floors (including penetrations) of all mechanical rooms above other areas. PART 3 - EXECUTION 3.1 APPLICATION Before applying waterproofing, surfaces shall be completely free of dirt and loose materials, concrete fins shall be chipped back, form ties removed and honey-combs, cracks, and other voids filled. Prime surfaces and otherwise prepare as recommended by the material manufacturer. Provide a layer of a suitable membrane protection material. Take care to avoid puncturing the membrane when backfilling against waterproofed foundation wall. SECTION 07 2100 BUILDING INSULATION

University of North Carolina at Charlotte Design and Construction Manual 1.1 PERFORMANCE REQUIREMENTS A. In addition to compliance with the State Energy Code, construction assemblies must have the following minimum R-values: 1. Walls: 19 2. Built Up Roofing: 25 3. Attic Ceiling: 30 1.2 SUSTAINABLILITY A. Batt insulation must be formaldehyde free B. Recycled Content: Provide glass-fiber insulation with recycled content so post-consumer recycled content plus one-half of pre-consumer recycled content is not less than 30%. SECTION 07 3113 ASPHALT SHINGLES A. Where possible, provide roofing products that meet the following reflectivity standards: 1. Solar Reflectivity/Emissivity: Energy Star. Solar Reflectance Index (SRI): a. Low sloped roof (less than or equal to 2:12): SRI of 78 or greater b. Steep sloped roof (greater than 2:12): SRI of 29 or greater 2.1 ASPHALT SHINGLES Federal Specifications SS-S-001534 Class A, Type 1 Self Sealing Fiberglass. Shingles shall meet the requirements of Underwriters Laboratories, Inc. for Class A, I-90, wind-resistant shingles, by equaling or exceeding the requirements of UL 55B, UL 790 and UL 997. Shingle bundle wrapping shall bear the label of Underwriters Laboratories, Inc. Shingles shall be square-butt strips of uniform thickness or of thick-butt style, with internal fiberglass matting, asphalt coating and ceramic surface granules. Size of shingles shall be approximately 12" x 36", 3-tab design; weight 205 lbs. per square. 2.2 UNDERLAYMENT Roofing Felt: ASTM D 226, asphalt saturated, organic, non-perforated, 30 lb, Type II. 2.3 ACCESSORIES A. Roofing Nails B. Material Galvanized Steel C. Head Diameter 3/8" D. Length sufficient to penetrate roof sheathing. E. Shank 11 or 12 gauge.

F. STAPLES ARE NOT ACCEPTABLE G. Bituminous Plastic Cement FS-SS-C-153, Asphaltic Base, Type I. SECTION 07 4113 METAL ROOF PANELS A. Where possible, provide roofing products that meet the following reflectivity standards: B. Solar Reflectivity/Emissivity: Energy Star. 1. Solar Reflectance Index (SRI): a. Low sloped roof (less than or equal to 2:12): SRI of 78 or greater. b. Steep sloped roof (greater than 2:12): SRI of 29 or greater. C. Recycled Content of Steel Products: Provide products with an average recycled content of steel products so post-consumer recycled content plus one-half of pre-consumer recycled content is not less than 60 percent. 2.1 PANEL MATERIALS Sheet Metal shall be Base and Counter Flashing SMACNA Plate as applicable or required, 26- gauge, Galvanized Metal. 2.2 ACCESSORIES A. Concealed Flashing: Concealed flashing shall be "Fiberweb 310" thru-wall flashing as manufactured by Fiberweb International Corp., "Cop-A-Bond" 202 weight as manufactured by AFCO, Duplex "Cop-R-Flash" as manufactured by Phoenix, "Cop-R-Tex Duplex" as manufactured by York Manufacturing or an approved equal. B. Gutters and Downspouts: Gutters and downspouts shall be 24 gauge; pre-finished aluminum in color as shown on the drawings. Provide all fasteners, elbows, screens, splashblocks and other accessories required for a complete installation of gutters and downspouts. C. Fasteners: All nails, screws, bolts, rivets and other fastenings for sheet metal, unless otherwise noted, shall be type 304 or 305 stainless steel of size and type suitable for intended use. Nails shall be minimum 12 gauge, flat head annular-thread type, and of sufficient length to penetrate backing at least 3/4". Galvanized steel is not acceptable. D. Solder: Solder shall conform to ASTM Designation B 32T, 60-40 or 80-20 percent block tin and pig lead. E. Flux: For tinning galvanized steel surfaces, use acid type flux designed especially for use in soldering galvanized steel. For re-tinted surfaces, use regular rosin type flux. 2.3 FINISHES A. When located in the academic core, they will be standing seam. The color will be gray to match the roof of the Barnhardt Student Activities Center. If located in the vicinity of the athletic fields, metal roofs will be dark green to match the Irwin Belk Track and Field Center.

SECTION 07 4213 METAL WALL PANELS Recycled Content of Steel Products: Provide products with an average recycled content of steel products so post-consumer recycled content plus one-half of pre-consumer recycled content is not less than 60 percent. 2.1 ARCHITECTURAL PANELS A. Refer to drawing C-017.10 for selection of architectural panels, size, seam location, and configuration. B. Acceptable architectural panel materials are: 1. Manufacturer: Citadel a. Type: glazeguard 1000 b. Size: 5'x12'x1" sheets with batten moldings to cap seams c. Color: clear stock anodized 2. Manufacturer: Greensteel a. Type: typical 5-ply insulating panel b. Size: 5'x12'x1" sheets with batten moldings to cap seams c. Color: clear stock anodized 3. Manufacturer: Laminators Incorporated a. Type: System II b. Size: 5'x12'x1" sheets with batten moldings to cap seams c. Color: clear stock anodized. SECTION 07 5000 ROOFING SYSTEMS 1.1 PERFORMANCE REQUIREMENTS A. Design: Roof designs shall comply with the latest version of the State Construction Office s Roofing Design Criteria. B. Re-roofing: 1. The Designer shall have a core sample taken of each existing roof system to determine the materials contained in each existing system. The Designer shall not rely on previous construction documents or record documents for this information. 2. Guarantee: Insert the following into the Supplementary General Conditions involving roofing of existing structures: The Contractor shall be responsible for all repairs of water damage to the building, including furnishings, occurring during the construction phase of the project. The Designer shall survey, in the presence of the owner and contractor, existing water damage prior to construction and prepare a written and photographic record of this survey with copies distributed to both the owner and contractor. The contractor shall be responsible for all damage not so documented. C. The Designer shall have a roofing analysis report made of the existing roof materials to determine the presence of asbestos. The Construction Documents shall include the complete report and interpretation.

1.2 SUSTAINABILITY A. Where possible, provide roofing products that meet the following reflectivity standards: B. Solar Reflectivity/Emissivity: Energy Star. 1. Solar Reflectance Index (SRI): a. Low sloped roof (less than or equal to 2:12): SRI of 78 or greater b. Steep sloped roof (greater than 2:12): SRI of 29 or greater C. Preference should be given to roofing systems that are able to be recycled. 2.1 GENERAL REQUIREMENTS A. For low-sloped roofs, the top surface color shall be white: this may be achieved with a white roofing membrane or white smoothly rounded (river washed) stone ballast. B. Drainage: Extra slope to roof drains should be provided two feet around the drain. Prior to final inspection, the contractor shall conduct a flood test of the roof in the presence of the Designer and the Owner to verify drainage. C. Flat membrane roofs - will be white roofing materials only. SECTION 07 6200 SHEET METAL FLASHING AND TRIM 1.1 QUALITY ASSURANCE Specifications for products included in this Section and accessories shall meet the ANSI, SMACNA and ASTM criteria for each material. Use flashing recommended by manufacturer as part of roofing system where applicable. 1.2 SUSTAINABILITY Recycled Content of Steel Products: Provide products with an average recycled content of steel products so post-consumer recycled content plus one-half of pre-consumer recycled content is not less than 60 percent. 2.1 MATERIAL Flashing to be either Stainless steel or copper, unless otherwise approved by UNC Charlotte SECTION 07 7000 ROOF ACCESSORIES 2.1 ROOF SCUTTLE A. Scuttle shall be Type 'S' by The Bilco Company, RSL-3036 by Naturalite Company, RD-1 by Milcor Limited Partnership or approved equal.

1. Clear opening (inside of curb) shall be 2'-6" x 3'0". 2. Cover shall be 11 gauge aluminum with 3" neatly welded beaded flange, insulated with 1" fiberglass, fully covered and protected with an 18 gauge aluminum liner. 3. The roof curb shall be 12" in height and be constructed of 11 gauge aluminum. The curb shall be formed with an integral predrilled 3½" flange for securing to the roof deck. 4. The curb shall be equipped with an integral 11 gauge aluminum cap flashing, fully welded at the corners for weather tightness. All clips, rope packing, etc. required for a proper fit and installation as described by the scuttle manufacturer shall be provided and installed by the Contractor. 5. Insulate the side walls of the curb with 1 thick rigid fiber board insulation (provided attached to the curb by the Manufacturer). 6. Scuttle shall be completely assembled with heavy duty hinges, spring operators to assist opening, a positive snap latch with turn handles and padlock hasps inside, and thermoplastic rubber gasket. 7. The cover shall be equipped with an automatic hold-open arm with vinyl grip handle for easy release and one hand control of cover to its closed and latched position. SECTION 07 9200 JOINT SEALANTS Provide sealants that have a VOC content of 250 g/l or less when calculated according to 40 CFR 59, Subpart D (EPA Method 24). 2.1 GENERAL REQUIREMENTS Joint Sealers Indicate that caulk selection by the designer shall not be limited to the manufacturer s standard list of colors. SECTION 07 9500 EXPANSION CONTROL 2.1 GENERAL REQUIREMENTS Building Expansion joint covers on interior floors shall be of color and texture that matches adjacent carpet or floor covering. Aluminum covered joints shall be avoided.