Instructions Chain drive series HCV. Type: HCV (24 V DC)



Similar documents
Instructions Chain drive series HCM. Type: HCMA(R) (230 V AC)

HERZ-Thermal Actuators

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

ZC-24DO CANopen I/O Module: 24 Digital Outputs

Rotary actuator for 2 and 3-way (control) ball valves Torque 5 Nm Nominal voltage AC V Control: Open/close or 3-point Auxiliary switch

Inwall 4 Input / 4 Output Module

Digital Keypad Use s Manual

AC-115 Compact Networked Single Door Controller. Installation and User Manual

ACS-30-EU-EMDR-10-MOD

Digital input modules

Air damper actuators

RRV934. Multi-controller. Synco living

Technote. Frese OPTIMA Compact actuators DN10-DN32. Application. Features thermic actuators. Features motoric actuators. Approval.


Electric Rotary Actuator - On/Off or programmable control actuator

How To Drive A Compact Serie 1

Infrarot-Bewegungsmelder IP44

Installation and Operating Manual p. 23. Radio push button 2 channel: HM-PB-2-WM55-2

DALI RC BASIC SO. Control unit Operating instructions

EPGM1 HARDWIRED ZONE & PGM OUTPUT EXPANSION MODULE

Floodlight Range Installation Guide

Nest Learning Thermostat Installation Guide. Installation step-by-step

The future electrical opening system for skylights, smoke hatches and windows

REB 1 REB 3 REB 5 REB 6 REB 8 REB 10 REB 12 REB 16

Manuale di istruzioni per l uso. INSTRUCTION MANUAL MODE D EMPLOI BEDIENUNGSANLEITUNG MANUAL DE INSTRUCCIONES Инструкция по монтажу

Combi B Alarm box. Mounting instructions

R60 USB to CAN interface Manual (1.5 EN)

Multifunction devices

StructureScan HD Module. Installation Guide ENGLISH

Manual for Fire Suppression & Methane Detection System

Technical Description. Transistor D.C. Chopper Controller Type GS 24 S

Machine Documentation BELKI Oil Separator type 301

Manual. Simrad StructureScan LSS-1 Sonar Module. English

DBS720 / FDS221-R / FDS221-W Sounder base, Alarm sounders

+ Incremental interface

FDCI222, FDCIO222, FDCIO224 Input module Input/output modules

SVR 12/24V and SVR Akku 12V Installation instructions

GREISINGER electronic GmbH

RI-215A Operator s Manual. Part Number: RK Revision 0 Released: 10/3/05

Shutter Actuator Standard, 4-fold, 230 VAC, MDRC RA/S , GH Q R0111. ABB i-bus EIB

ICON Server box installation manual Rev. 1.1

Switch Actuator, 8-fold, 10 A, MDRC AT/S , GH Q R0111

RAILWAY TECHNOLOGY INDUCTIVE COMPONENTS INDUKTIVE KOMPONENTEN FÜR DIE BAHNTECHNIK

Rousseau 10. User Guide

SNQ-60x0-320 Series Data Center Switch. Quick Installation Guide

MAKING MODERN LIVING POSSIBLE. living connect. Installation and User Guide. Danfoss heating

Power Supply and Indicator Unit Type Fig. 1 Type Mounting and Operating Instructions EB 9539 EN

Series LC6D/LC6C. To power supply PLC. LC6C dedicated teaching box P.971. Options P.973

Water Leak Detection System

New XUY roller sensors

MICA HEATER INSTRUCTION MANUAL Model No: UHM V 50Hz 2200W

Operating Instructions Bedienungsanleitung Mode d emploi

Quick start guide smart.power smart.power smart.power

How To Power A Power Control On An Ip40 (Ipl) With A Power Supply (Iplug) With An Ip20 Controller (Iphones) With Power Control (Power Control) With No Antenna) With The Ip20 (Power)

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

AIR CONDITIONING SYSTEMS

AN500T, AN1000, AN1000T, AN1500, AN1500T AN2000, AN2000T

TS93 EMR T/PT/TDE. Surface applied door closer

PSU-U-24V/AC-6A/10/FTA-TR-MC PSAC 0624

Duct Humidity Transmitter

T-05-S2. Rotary drive without spring return. Technical data sheet. Description. Technical data. Actuators

Data logger. Installation and operating instructions. Read carefully before installation, commissioning and operation.

Stove Guard Kit User Manual

Operating Instructions

Operating Instructions

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

S t a r T r a d i n g. M e i j n e r s w i j k 1 3 B H A A r n h e m ( 0 ) ( 0 )

INSTRUCTION MANUAL. SIGNAL AMPLIFIER 4-20 ma

CELO5. User & Installation Manual.

PSDC PSDC 12V/8A/8x1A Power supply for up to 8 analog cameras PTC/TOPIC.

Operating Instructions. Keypad

Rapide Inline Ceiling Extractor Fan, White Fascia Rapide Inline Ceiling Extractor Fan, Chrome Fascia

POINTS POSITION INDICATOR PPI4

PRELIMINARY MANUAL STAGE COLOR 48. Preliminary User Guide. Official version will follow soon on: TABLE OF CONTENTS

Mureva Assembly surface mounted wiring devices

User Manual. Before installation and use, please read the user manual carefully.

=============================== WARNING

EPM3. Phase Sequence and Motor Rotation Tester. Users Manual

ABB-Welcome M M M Audio handset indoor station VER:

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

alpha DSL WTM HS Instructions for use ADSL modem alpha DSL WTM HS

VP23, 3-way proportional pressure control valves Seat valve with μp-driven pressure control

Drayton Digistat +2RF/+3RF

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N

PA5. Series. Quick-Connect Cables with Connectors. Simplifies sensor wiring. Wide variety of connectors attached to cables.

ABB Stotz-Kontakt GmbH ABB safe&smart Project planning of security systems

Sealed Industrial Ethernet Circular IP67 Cat. 5e RJ45 Connector System

LS1024B / LS2024B/ LS3024B. Solar Charge Controller USER MANUAL

DCP Fan Controller. Version 01/2009. The engineer s choice

Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate

Communication bridge Xcom-MS User Manual

SECTION G2: CABLE PROCESSOR MODULE MAINTENANCE

FIRE ALARM AND DETECTION SYSTEMS SECTION 16721

GeekDesk Max Instructions for Assembly & Use

SECURITY SYSTEM ADP-CAN

Operating Instructions

Investigation of sound insulation for a Supply Air Window field measurements and occupant response

PolyGard Carbon Monoxide CO Transmitter ADTX3 1110

Manual & Technical Documentation V1.1

Transcription:

Instructions Chain drive series HCV Type: HCV (24 V DC)

Safety Notes - Operating voltage 24 V DC! Don t connect directly to grid! - Connection must be carried out by authorized electricians. - It s necessary to ensure that people keep away from the operation area of the drives. Danger of violent pressure in accessible area! - Use only in dry rooms. Application area - For opening and closing of facade and roof windows - Suitable for smoke and heat ventilation and daily ventilation Stroke-pushing force diagram - Maximum pushing force of chain is dependent on stroke and does not correspond to the maximum pushing force of drive! Max. Trykkraft (N) stroke (mm) (mm) 2 / 12

Features - Microprocessor controlled BUS-synchronization - Max. 8 drives can be connected with each other - Push/Pull-Force, Opening/Closing-Speed and Stroke length free programmable - Electronic overload protection - Gasket relief after closing - Reduced speed and force during the last 50 mm of closing ( Soft-close ) - 2 different speeds, one for daily ventilation (slow) and one for SHEV (fast) - Aluminium alloy housing with special surface treatment - Drive is supplied with 2.5 m silicone cable - Different types of brackets available, depends on type of windows and kind of mounting - Compatible to all Actulux 24 V SV and SVM Control Panels - Tested according to EN 12101-2 Technical data Type Current Push force Pull force Stroke length Speed open (HS) Speed close HCV 300/350 1.0 A 300 N 300 N 350 mm 7 mm/s 7 mm/s HCV 300/600 1.0 A 300 N 300 N 600 mm 10 mm/s 10 mm/s HCV 300/800 1.0 A -- 300 N 800 mm 14 mm/s 10 mm/s HCV 300/1000 1.0 A -- 300 N 1000 mm 17 mm/s 10 mm/s HCV 500/350 1.4 A 500 N 500 N 350 mm 7 mm/s 7 mm/s HCV 500/600 1.4 A 500 N 500 N 600 mm 10 mm/s 10 mm/s HCV 500/800 1.4 A -- 500 N 800 mm 14 mm/s 10 mm/s HCV 500/1000 1.4 A -- 500 N 1000 mm 17 mm/s 10 mm/s - Voltage: 24 V DC ± 15 % - Protective class: IP32 - Locking force: 1000 N - Temperature range: -5 C ~ +50 C - Lifecycle: >10000 double strokes - Soft close speed: ca. 5 mm/s - Duty cycle: 30% at 10 min. running time - Soft close distance: 50 mm 3 / 12

Dimensions of type HCV Stroke Length L 350 mm 436 mm 600 mm 561 mm 800 mm 661 mm 1000 mm 766 mm Connection for type HCV in single mode For line surveillance a third wire is necessary. Connect a 27kΩ resistor between terminal 1 and the blue wire. Further set jumper J2 and J3 like shown in drawing. If no line surveillance is necessary, remove jumper J2 and J3. J2 J3 4 3 2 1 Actuator line surveillance 3 wire line surveillance (Line 1) 24 V Out 1 2 3 Line 1 A A Alarm Out COM NC NO 4 5 6 Failure Out COM NC NO 7 8 9 blue red orange white grey R 27kΩ Caution: The cables of white and grey are only for changing parameters by an authorized service and sales partner by Actulux. Don t connect the cabels of white and grey to 24V! 4 3 / 12 8

5 /12 12 Connection for type HCV in synchro mode J2 Actuator line surveillance J3 3 wire line surveillance (Line 1) red blue 4 3 2 1 24 V Out Alarm Out COM NC NO Failure Out COM NC NO 1 2 3 Line 1 A A 4 5 6 7 8 9 blue red orange white grey R 27kΩ grey white orange red blue Caution: The cables of white and grey are only for changing parameters by an authorized service and sales partner by Actulux or for BUS communication in synchro mode. Don t connect the cabels of white and grey to 24V! For line surveillance a third wire is necessary. Connect a 27kΩ resistor between terminal 1 and the blue wire of the last drive. Further set jumper J2 and J3 like shown in drawing. If no line surveillance is necessary, remove jumper J2 and J3.

Mounting information Application Bracket Set Order No. Outwards opening window, top hung HMB-HCV-01 390000 Inwards opening window, bottom and side hung HMB-HCV-02 390120 Skylight HMB-HCV-03 390130 Please be aware, that in all bracket sets are no screws included. Choose proper screws according to frame material! HMB-HCV-01 6 / 12

Stroke Y 350 mm 227 mm 600 mm 352 mm 800 mm 452 mm 1000 mm 557 mm 8 7 / 12 / 12

HMB-HCV-02 Stroke X 350 mm 215 mm 600 mm 340 mm 800 mm 440 mm 1000 mm 545 mm 8 / 12

HMB-HCM-03 for skylights 9 / 12 9 / 12

Stroke X 350 mm 215 mm 600 mm 340 mm 800 mm 440 mm 1000 mm 545 mm 10 / 12

Declaration of performance No. 003CPR2013-05-14 (DK) YDEEVNEDEKLARATION IHT. FORORDNING NR. (EU) 305/2011) (UK) DECLARATION OF PERFORMANCE ACCORDING TO REGULATION NO. (EU) 305/2011) (D) LEISTUNGSERKLÄRUNG GEMÄSS DER VERORDNUNG NR. (EU) 305/2011) For produktet: For the product: Für das Produkt: Type/Type/Typ: Kædemotor Chain drive Kettenantrieb HCV xxx/xxx og/and/und HCV-S xxx/xxx Nr./No./Nr.: 310035 311120 og/and/und 314035 315120 Formål: Purpose: Verwendungszweck: Producenten: Manufacture: Hersteller: Elektrisk motor til åbning og lukning af vinduer Electric drive for opening and closing of windows Elektrischer Antrieb zum Öffnen und Schließen von Fenstern Actulux A/S, Haandvaerkervej 2, 9560 Hadsund Denmark System for attestering og kontrol af ydeevne: System for attestation and verification of performance: SYSTEM 1 System zur Bescheinigung und Prüfung der Performance: Det bemyndigede organ TÜV SÜD Product Service GmbH No 0123 gjorde den indledende inspektion af fabrikken og af dennes egen produktionskontrol samt løbende overvågning, vurdering og evaluering af fabrikkens egen produktionskontrol til SYSTEM 1, og følgende vises: The notified body TÜV SÜD Product Service GmbH No. 0123 made the initial inspection of factory and of factory production control, and ongoing monitoring, assessment and evaluation of factory production control to the SYSTEM 1 and the following is displayed: Die notifizierte Stelle TÜV SÜD Produkt Service GmbH Nr. 0123 hat die Erstinspektion des Werkes und der werkseigenen Produktionskontrolle sowie die laufenden Überwachung, Bewertung und Evaluierung der werkseigenen Produktionskontrolle nach dem SYSTEM 1 vorgenommen und Folgendes ausgestellt: Deklarerede ydeevne/declared performance/erklärte Leistung: EC CERTIFICATE OF CONFORMITY NO. E8N 13 04 84583 001 Feature/Feature/Merkmal Ydeevne/Performance/Leistung Specifikation/Specification/Spezifikation EMC/EMC/EMV Class III (24 V DC) EN 61000-6-1:2007 og/and/und EN 61000-6-3/A1:2011 Udførelsen af produktet i overensstemmelse med punkt 1 og 2 svarer til den deklarerede ydeevne for nummer 9. Ansvarlig for at skabe denne ydeevnedeklarationen er producenten henvist til punkt 4. Underskrevet på vegne af fabrikanten og navnet på fabrikanten af: The performance of the product in accordance with paragraphs 1 and 2 corresponds to the declared performance for number 9. Responsible for creating this declaration of performance is the manufacturer referred to point 4. Signed on behalf of the manufacturer and the name of the manufacturer of: Die Leistung des Produkts gemäß den Nummern 1 und 2 entspricht der erklärten Leistung nach Nummer 9. Verantwortlich für die Erstellung dieser Leistungserklärung ist allein der Hersteller gemäß Nummer 4. Unterzeichnet für den Hersteller und im Namen des Herstellers von: Hadsund d. 14 May 2013, Jens Buus, Managing director 11 / 12

Warranty The warranty period is 2 years for all Actulux products from the date of verified handing over the system up to maximal 5 years after the date of delivery if the installation and implementation is performed by an authorized service and sales partner by Actulux. Disposal Electrical equipment, accessories and packaging should be recycled for environment protection! Don't dispose electrical equipment into household waste! Only for EU-Countries: According to the European guideline 2002/96/EG about waste electrical and electronic equipment and its implementation into national law, useless electrical and electronic equipment must be separately collected and recycled for environment protection. Contact Actulux A/S Håndværkervej 2 DK-9560 Hadsund Denmark Fon: +45 98 57 40 90 Fax: +45 96 15 28 00 www.actulux.com 2015 Actulux A/S Revision: A04 Rights to technical modifications reserved 12 / 12