2012 Ontario Building Code Changes Affecting Fire Alarm Systems

Similar documents
CFAA NCR CHAPTER ANNUAL SENINAR. Commonly Overlooked Fire Alarm Requirements

FLORIDA ATLANTIC UNIVERSITY FIRE ALARM SYSTEM INSTALLATION MANUAL

BUILDING OWNERS - SERVICE RELATED ISSUES FOR FIRE ALARM SYSTEMS

FIRE ALARM SYSTEM RECORD OF COMPLETION

FIRE ALARM SYSTEM RECORD OF COMPLETION

OBOA 2009 Huntsville, ON Overview of ULC Standards Affecting Building Occupancy Alan Cavers Area Manager Fire & Security Systems Group

City of Bettendorf Fire Alarm System Requirements

PARTICIPATION HOUSE 9 BUTTERNUT LANE, MARKHAM

ENVIRONMENTAL HEALTH & SAFETY 6 East Dr., Amherst MA

CAN/ULC S Integrated Systems Testing of Fire Protection and Life Safety Systems and Fire Protection Commissioning

2007 ICC FINAL ACTION AGENDA

TAMARAC FIRE RESCUE INSTRUCTIONS FOR FIRE ALARM PRE-SUBMITTAL CHECKLIST

Rancho Cucamonga Fire Protection District Prevention Bureau Standard

CLARK COUNTY FIRE DEPARTMENT Fire Hazard & Prevention Services

PLAN REVIEW GUIDE FOR FIRE ALARM

SECTION FIRE ALARM AND DETECTION SYSTEM

FIRE ALARM AND EMERGENCY COMMUNICATION SYSTEM RECORD OF COMPLETION

Fire Alarm Engineering Best Practices. CFAA NCA Technical Seminar 2014

Life Safety Code Enabling References

Fire Alarm System Plans Review Checklist Property location Date of Review

Design Standards Fire Alarm Systems Division (1995 CMS); (2004 CMS) Amended Feb 2015

CAN/ULC-S Installation and Services for Fire Signal Receiving Centres and Systems- Ottawa 2013

COMMONWEALTH OF MASSACHUSETTS STATE BUILDING CODE 780 CMR, 6 th Edition FIRE PROTECTION SYSTEMS CHAPTER 9

Area of Rescue Assistance Communication System ADA Code Applicable excerpts:

Fire Alarm System Monitoring, a Primer for the Property Owner David Duggan, 2005

Rhode Island State Fire Marshal Fire Protection Systems Narrative Reports. What is a Narrative Report?

FIRE RATED WIRING. What the FT4! Paul Latreille, C.E.T. Ottawa Branch Manager

IR F-1 EMERGENCY VOICE/ALARM COMMUNICATION SYSTEMS

University Design Standard. Fire Alarm Systems

FIRE CODE INTERPRETATION

FIRE ALARM SYSTEM SUBMITTAL CHECKLIST AND APPLICATION

FIRE DETECTION AND ALARM

FIRE-FIGHTING DESIGN BRIEF REPORT

Fire Alarm System Plans Submittal Guidelines For New and Existing Systems

MINIMUM STANDARDS FOR HIGH-RISE BUILDINGS

Sprinkler and Fire Alarm Systems for the Building Official

EXHIBIT A SCOPE OF WORK

Mobile Fire Rescue Department Bureau of Fire Prevention

Overview of Hotel Fire Safety Requirements

AETNA FIRE ALARM SERVICE CO., INC.

NC State University Design and Construction Guidelines Division 26 Fire Alarm Systems

SARATOGA FIRE DISTRICT EARLY WARNING FIRE ALARM SYSTEM STANDARDS AND REQUIRMENTS CONTENTS

CITY OF PHILADELPHIA DEPARTMENT OF LICENSES AND INSPECTIONS ANNUAL CERTIFICATION FOR FIRE ALARM SYSTEMS

FIRE ALARM SYSTEMS PERMIT APPLICATION, PLAN SUBMITTAL, DESIGN, INSTALLATION AND INSPECTION REQUIREMENTS Effective Date: January, 2011

FIRE ALARM AND EMERGENCY COMMUNICATION SYSTEM INSPECTION AND TESTING FORM

Bold items are particular to the City of Euless

SECTION FIRE ALARM AND SMOKE DETECTION SYSTEMS

SECTION FIRE AND SMOKE ALARM SYSTEM. City of San Diego, CWP Guidelines

(1) Signals to Fire Department A new requirement inserted due to a new defined use for Group C retirement homes.

Module 4, Lesson 12 Fire Alarm Systems

DTW Works Master Specification Version 2006

DELAWARE STATE FIRE MARSHAL FIRE ALARM SYSTEM CERTIFICATE OF INSTALLATION

BUILDING DESIGN STANDARDS UNIVERSITY SERVICES ELECTRONIC SAFETY AND SECURITY - DIVISION 28 Fire Alarm Systems

The Mission Critical Fire Protection Experts

Understanding Fire Alarm Requirements & Inspections. Presented By Bill Conroy Technical Sales For Briscoe Protective Systems Inc

Fire Alarm System Monitoring - CAN/ULC-S561-03

Interfacing Elevators with Fire Alarm and Sprinklers

Finance and Administration Department 907 Billy Mitchell Blvd. P: (210) Fire Alarm Permit Application

INSTRUCTIONS FOR BUILDINGS WITH FIRE PROTECTION EQUIPMENT

ALBERTA FIRE CODE SAFETY EQUIPMENT MAINTENANCE REQUIREMENTS

Program No Section Heading

FIRE ALARM SYSTEM. A. Shop drawings shall be submitted as follows: 1. Manufacturer's published literature. for aspproval.

FIRE SPRINKLER SYSTEM SUPERVISORY SERVICE User s Guide (DamarNet RAR Service)

Module 5. Fire and Emergency Alarm System Part I- Basics

FireSeeker Fire Alarm Control Panel Model FS-250 Programming Manual

CBD-233. Fire Alarm and Detection Systems

HERNANDO COUNTY FIRE ALARM GUIDELINES

General Safety & Health Standards Published by the Division of Building Safety In Cooperation with the Idaho Industrial Commission

Telluride Fire Protection District Fire Alarm Systems Policy Version 03/2007

Fire Alarm Trainee Log Book

COMMISSIONING OF FIRE ALARM SYSTEMS

CHANGES IN NFPA 72 NATIONAL FIRE ALARM CODE

Winnipeg Fire Department Fire Prevention Branch

SECTION FIRE ALARM AND DETECTION SYSTEMS

MINNESOTA HEALTH CARE ENGINEERS IN ASSISTED LIVING FACILITIES

Fire Alarm Systems Requirements by Occupancy Type

Original Document 10/16/07 Revised 01/30/09 2 nd Revision rd Revision- 12/18/14

City of Columbus Department of Building and Zoning Services

CHAPTER 9 FIRE PROTECTION SYSTEMS

FIRE ALARM /FIRE PROTECTION OUTAGE/IMPAIRMENT RESPONSE GUIDELINE

Fire Alarm FAQs. Q: How many zone/circuit fire alarm panel do I need? Q: What candela strobes do I need?

Michael Catalano 24 Nassau Avenue, Islip NY Phone (631) Chief Fire Marshal Fax (631)

Proposed changes to the Acceptable Solution for Building Code clause F7 (Warning Systems) Proposed amended Acceptable Solution for Warning Systems

Required Certification Documentation. Contractor's installation certification for range hood fire suppression systems.

Fire Alarm Submittal Requirements and Acceptance Testing

NATIONAL FIRE ALARM AND SIGNALING CODE

FIRE ALARM PLAN REVIEW. Office of the State Fire Marshal Massachusetts Department of Fire Services December 2009

Depending on your facility and the equipment contained within, all or part of the checklists/logs can be printed for use.

JULY 2013 UCB STANDARDS

Amerex CPS FM-200 Waterless Pre-engineered Fire Suppression System

1. The objective of this guideline is to provide minimum standards for design and installation of fire alarm systems for the University of Missouri.

We hope these Frequently Asked Questions will be of use both to municipal officials and fire inspectors.

Fire Alarm and Detection Systems And Central Station Monitoring Plan Submittal Guidelines

FIRST ALERT INSTRUCTION MANUAL FOR FA 270 KEYPADS SECURITY SYSTEM

NY Fire Safety Institute

* Any required illumination shall be arranged so that the failure of any single lighting unit shall not leave any area in darkness.

HONEYWELL COMMERCIAL FIRE/BURG PANEL UL LISTING REQUIREMENTS (Compiled from VistaFBPT Installation Instructions V1 Rev A 11/12)

HOUSTON FIRE DEPARTMENT HIGH-RISE SURVEY CHECKLIST

Overview of Fire Alarm Systems and Maintenance

Transcription:

2012 Ontario Building Code Changes Affecting Fire Alarm Systems CFAA Annual Technical Seminar May 31, 2013 Ken Baird VP Systems www.lrifire.com LRI 2010

Developments in Life Safety Introduction Code Development Overview in Canada Who is responsible for Building Life Safety Building and Fire Code Application Implication of Fire and Life Safety changes included in the 2012 Ontario Building Code (OBC) Additional CSA B-44 requirements for elevators Verification and testing of life safety systems 2

MAINTAINING BUILDING LIFE SAFETY WHO IS RESPONSIBLE? The building owner is responsible for life safety of the occupants in their building Typically the owner engages others to assist in meeting this obligation If the building owner fails to ensure the requirements are met this can result in fines, a jail term or both Others who contract to provide services may also be held at fault, if they fail to carry out the services for which they contracted 3

CODES Building Codes Applicable to new construction Fire Codes Applicable to operation and maintenance National Building Code (NBC) model code A model set of technical requirements designed to provide an acceptable level of fire and life safety within a community. Forms the base of all Provincial Building Codes Permits adoption by an appropriate authority Constitution Act Regulation in Canada identifying provincial and territorial governments as responsible for building and fire safety 4

BUILDING CODES Building Code Application New buildings Existing buildings Reconstruction, renovation, alteration Extension/addition Changes in occupancy 5

2012 ONTARIO BUILDING CODE Legislation enabling the 2012 Ontario Building Code was passed in 2012 The 2012 Ontario Building Code will not come into force until January 1, 2014 The new OBC can be viewed on the Government of Ontario website, no published version is currently available Based upon the 2010 National Building Code Sections relating to fire alarm appear identical 6

Fire Code Application Existing Buildings Fire prevention FIRE CODES Fire fighting and life safety in buildings Uses, activities, hazards, limitations Service and Maintenance Emergency plans (reviewed annually and updated as needed) A revised Fire Code is complete No date has been set for its release 7

REFERENCED STANDARDS Codes and Standards Regularly reviewed and revised by balanced committees based on geography, technical expertise and industry focus Standards are referenced by date of issue in the body of the Codes and Standards and include ULC, CSA NFPA, ULI, FM, ANSI, ASME etc 8

BUILDING CODES and STANDARDS Building Codes and Standards typically are reviewed, revised and reissued every 5 years to address Changes in product technology Increased hazards from newer construction and finishing materials Changes identified by inquests Changes in other Standards Errors, omissions or missing detail 9

CODE CYCLES AND TIMING Unfortunately, Codes are already stale by the time they become effective By its effective date of Jan 1 st 2014 the OBC requirements will be based on material developed 6 to 7 years prior Industry Technology change far outpaces our ability to reflect it in current Codes Its imperative that in addition to adhering to the published Codes, we create designs based upon good engineering practice 10

2012 Ontario Building Code Changes Affecting Fire Alarm Systems included in the 2012 Ontario Building Code 11

CONTINUITY OF FIRE ALARM SYSTEMS Non high rise buildings interconnected by walkways or tunnels can have independent fire alarm providing For walkways, each building must have a 45 min fire separation from walkway For tunnels, each building must have 1 h fire separation from tunnel 12

CONTINUITY OF FIRE ALARM SYSTEMS CONNECTED LOWRISE BUILDINGS REQUIRED -MANUAL STATIONS AT EXIT FROM EACH BUILDING -SMOKE DETECTORS IN EACH BUILDING AT BRIDGE OR TUNNEL RECOMMENDATION -WARNING "DO NOT ENTER FIRE " SIGN AT ENTRY TO BRIDGE OR TUNNEL. OPERATED BY ADJACENT BUILDING ON ALARM -BUILDINGS CONNECTED FOR 1st & 2nd STAGE ALARM 45min Fire Separation Bridge 1 hr Fire Separation Tunnel

CONTINUITY OF FIRE ALARM SYSTEMS Allows high rise buildings interconnected by walkways or tunnels to have independent fire alarm providing For walkways, each building must have a 45 min fire separation from walkway For tunnels, each building must have 1 h fire separation from tunnel Vestibules must be designed to limit smoke movement (Section 3.2.6) 14

CONTINUITY OF FIRE ALARM SYSTEMS CONNECTED HIGHRISE BUILDINGS REQUIRED -MANUAL STATIONS AT EXIT FROM EACH BUILDING -SMOKE DETECTORS IN EACH BUILDING AT BRIDGE OR TUNNEL -VESTIBULES TO LIMIT SMOKE MOVEMENT RECOMMENDATION -WARNING "DO NOT ENTER FIRE " SIGN AT ENTRY TO BRIDGE OR TUNNEL. OPERATED BY ADJACENT BUILDING ON ALARM -BUILDINGS CONNECTED FOR 1st & 2nd STAGE ALARM 45min Fire Separation Bridge Vertibules Limit Smoke Movement (e.g. Pressurization or Venting) 1 hr Fire Separation 15

ANNUNCIATOR ZONE INDICATION Kitchen Fire extinguishing system Individual zone display for each extinguishment system Comply with NFPA 96, Ventilation Control and Fire Protection of Commercial Cooking Operations, 16

FIRE PUMP SUPERVISION Supervise fire pumps as stipulated in NFPA 20 Installation of Stationary Pumps for Fire Protection Electrical Supervision includes; Suction Valve Discharge valve Bypass valves Loss of power Pump Trouble 17

ELEVATORS Based on OBC Elevator Hoistway: Individual zone display for Fire Detector required in elevator hoistway if separately zoned sprinkler not installed Typically a heat detector is installed at the base and a smoke detector at the top 18

ELEVATORS Based on OBC Elevator Machine Room Smoke Detectors required in Elevator machine rooms Must recall the Elevator(s) served by that machine room 19

ELEVATORS Based on OBC If automatic recall provided and primary recall level not sprinklered, then smoke detector required in lobby and alternate recall required Detector must be part of fire alarm system 20

ELEVATORS Based on CSA B44 Life safety requirements for elevators is also covered by CSA B44-07 which is enforced by TSAA Required by TSSA over and above the OBC in order to get an elevator license for new elevators Required by TSSA over and above the OBC in order to get re-licensed after a controller upgrade for existing elevators 21

ELEVATORS Based on CSA B44 CSA B44 Requirements Currently TSAA insist their requirements override those of the OBC if you want an elevator license Significant differences with many added requirements in the CSA B44-07 Code Automatic recall required for elevator with rise over 2 m Alternate recall required if recall level not sprinklered or there are landings below the recall level 22

ELEVATORS Based on CSA B44 Fire Alarm Input Devices Smoke detectors required in elevator lobbies (or in vicinity if no lobby) on all floors (not required by OBC) recalls all elevators in that bank Other automatic fire detection allowed to recall elevators but not required (sprinklers and floor detectors) Manual stations are not allowed to initiate recall Smoke detector installed in elevator machine room (required by OBC) Fire Detectors installed in Shaft (required by OBC) 23

ELEVATORS Based on CSA B44 Fire Alarm Control If building not required to have a fire alarm system by OBC, dedicated panel required to serve for elevator detection and recall requirements Although not covered by CSA B44, as a fire alarm panel in a building other requirements such as manual stations, sprinkler supervision, additional detection, alarm signalling, annunciation, verification and annual test is now required 24

ELEVATORS Based on CSA B44 Compliance Using Existing Fire Alarm Systems Addressable system format Smoke detectors in elevator lobby Programming to initiate elevator recall from floor devices excluding manual stations Addressable Relays for elevator recall 25

ELEVATORS Based on CSA B44 Compliance Using Existing Fire Alarm Systems Systems using conventional (non addressable) technology If spare capacity available, modify floor zones so manual stations on separate zones Add smoke detectors in elevator lobbies, machine rooms, elevator shaft The use of detectors with relay bases is not an acceptable solution if connected to floor as the relay will not function if a contact device is operated on same circuit If wired vertically, isolators required every level per S524 26

ELEVATORS Based on CSA B44 Compliance using a dedicated fire alarm system panel To be acceptable to most Authorities Must be integrated into building system to provide floor annunciation for alarms Provide alarm signaling throughout the building Release maglocks, fan control etc Where required by the OBC, initiate fire service response Follow good fire and life safety practices 27

ELEVATORS Based on CSA B44 Multiple points now required from fire alarm system to elevator controllers to: Initiate primary recall from elevator lobby smoke detectors, top of shaft and elevator machine room If alternate recall provided alarm from primary recall level or detector at base of shaft If alarm from floor device indicate Available for emergency service in elevator cab If alarm from elevator shaft or machine room indicate, Not to be used for emergency service in elevator cab 28

ELEVATORS Based on CSA B44 Impact of Elevator Changes In large complexes such as hospitals, will allow distributed elevator banks to continue operation Provides a safer means of egress for individuals with impaired mobility Interface/recall applies to all elevators (not just high rise) Smoke detectors now required in all elevator lobbies If primary recall level not sprinklered alternate recall required (no longer just for high rise) Manual stations not allowed to initiate recall, so floor zone cannot be used (problem primarily for existing FA systems) Verification and testing significantly more time consuming 29

FIRE ALARM ALERT SIGNAL Alert signals (to be) clearly audible in continuously staffed locations, and if there are no continuously staffed locations, throughout the floor area. Clarifies previous intent to ensure that supervisory staff are aware of fire alarm system operation Alert Signals do not need to operate throughout the building or portions of the building (provided supervisory staff are alerted) Alarm (EVAC) signals still generally required on floor of alarm initiation and floors above and below in high rise buildings 30

VOICE COMMUNICATION Intelligible Emergency Voice Messages The OBC has required voice communication to be intelligible for many Code cycles No measurable, repeatable criteria for acceptance was available Bose spearheaded a means to test systems in the field for intelligibility using software which reflects speech pattern Baring any changes prior to the OBC becoming effective, broadcast of pre-recorded, synthesized, or live voice messages will need to meet an equivalent score of 0.70 on the Common Intelligibility Scale (CIS) 31

VOICE COMMUNICATION Impact Meeting the.70 CIS results in a significantly greater number of speakers installed in closer proximity to one another Use of digitized messages provides best results, Added time needed for verification and testing Added time required to design conventional office spaces In large volume spaces, and areas with reverberant surfaces, an engineered sound solution approach will generally be needed 32

VOICE COMMUNICATION Emergency voice communication capability now required for additional occupancies Previously emergency voice communication capability was only required for high buildings New requirement to provide emergency voice communication for all occupancies regardless of height where a 2 stage fire alarm system is installed and The occupant load will be greater than 1000 people 33

Impact VOICE COMMUNICATION Will affect large assembly occupancies such as shopping malls, banquet facilities, arenas, auditoriums, retail, universities/colleges, etc. Where existing facilities are expanded the expansion will now require addition of voice communication capability Display Control Centre/annunciator add microphone and paging controls for expansion area, in some cases this may result in upgrade throughout Control equipment add voice control/amplifiers Network architecture requires a voice path from main control Signal types matching sound of bells, horns, tones Partial voice New section with voice, balance just tones? 34

SMOKE ALARMS Residential Occupancy smoke alarm Now requires smoke alarms be installed on every level as well as in every bedroom Alarm signal pattern now to be temporal pattern, proven to be more effective at waking individuals. Smoke alarm to have a local signal silence switch to reduce tampering Power from permanent connection (120 VAC) as well as battery suitable for 7 days followed by 4 min alarm 35

EXIT SIGNS New Display Format for Exit Signs Green pictograms conforming to ISO Standards Language independent Internationally recognized and conforms to universal sign format Could result in mixed signage in existing buildings where additions need to conform to the pictorial symbols 36

EXIT SIGNS Use of New Technology for Exit Signs Listed photoluminescent signs acceptable Continues to function after emergency power fails Provides easier cost effective installation Lower maintenance To be Acceptable must be Listed 37

COMMISSIONING Life Safety and Fire Protection Systems Where life safety and fire protection systems are installed to comply with the provisions of the OBC or the OFC, the commissioning of these integrated systems must be performed as a whole to ensure the proper operation and inter-relationship between the systems 38

COMMISSIONING Life safety Systems include Fire alarm Sprinklers Standpipes Smoke control Ventilation Pressurization Door hold open Elevator recall Maglocks 39

FIRE ALARM DESIGN Design Process Establish the Design Parameters to be utilized for the project New Construction, select the most appropriate infrastructure and technology Retrofit must consider how full fire alarm protection will be maintained duration transfer to new If replacing only the fire alarm panel, need to address outdated devices, wiring issues, audibility, etc 40

FIRE ALARM DESIGN Select Fire Alarm System Architecture Consider Survivability & Redundancy Careful use of network structure and wiring paths can achieve significant benefit with little or no cost Distributed architecture with processor based communication Using addressable components can provide detailed alarm location, fire growth information and detailed fault information Provides for future growth and flexibility 41

FIRE ALARM DESIGN Select Appropriate Architecture Cont d Computer control centre with colour graphics for large or complex systems Consider multiple DCC locations for multiple buildings, building operations and fire service response points Include digitized voice paging message broadcast for clearer intelligible messages Consider different operating sequences for two stage system based upon time of day and investigative personnel available 42

VERIFICATION, TESTING & MAINTENANCE Ensure all system additions or changes verified and documents maintained with service records Contract to have testing performed at required intervals, monthly, semi-annually and annually Use reliable qualified service providers Pre-qualify and identify expectation in detail in an RFP On a regular basis monitor the work and progress Require the test report on a timely basis on completion Review the report for deficiencies and have corrected on a timely basis Maintain reports for authorities for a minimum of 2 years 43

TESTING & MAINTENANCE The accuracy, reliability and timeliness of reports for the annual testing of life safety systems can be improved by: Utilizing a service provider who utilizes bar coding of devices (such as Building Reports Canada) and records in electronic format on site Uploading test results on a daily basis to a website where progress can be accessed and reviewed immediately Allows deficiencies to be reviewed while work in progress and corrected rather than waiting till end of testing work Ensures that technician actually gets to all devices Added protection for owner that work completed as agreed 44

Summary Today we have covered some of the changes in life safety which affect building construction, operation and maintenance Reviewed the 2012 revisions to the Ontario Building Code which affect Life Safety Systems Identified some of the challenges we will face as a result of the changes Identified requirements for verification and testing of integrated life safety systems System design suggestions to provide a more reliable, robust fire3 alarm system Identified ways we can improve our ability to scrutinize the timely work of our service providers 45

Thank you for your attention Questions? Ken Baird LRIFire kbaird@lrifire.com www.lrifire.com LRI 2010