CFAA NCR CHAPTER ANNUAL SENINAR. Commonly Overlooked Fire Alarm Requirements

Size: px
Start display at page:

Download "CFAA NCR CHAPTER ANNUAL SENINAR. Commonly Overlooked Fire Alarm Requirements"

Transcription

1 CFAA NCR CHAPTER ANNUAL SENINAR Commonly Overlooked Fire Alarm Requirements

2 Introduction of Who I Am And My Experience (aka: only legitimate chance to catch a quick nap) Definitions ( if you nap during this part you may miss out!) OBC: You May Not Know These Things 3.2.4: This Is Not The Only Fire Alarm Section ULC: You Just May Be Surprised INTRODUCTION

3 Alert signal means an audible signal to advise designated persons of a fire emergency. Alarm signal means an audible signal transmitted throughout one or more zones of a building or throughout a building to advise occupants that a fire emergency exists. Alternative solution means a substitute for an acceptable solution. Contained use area means a supervised area containing one or more rooms in which occupant movement is restricted to a single room by security measures not under the control of the occupant. Fire compartment means an enclosed space in a building, (a) that is separated from all other parts of the building by enclosing construction that provides a fire separation, and (b) that may be required to have a fire-resistance rating. DEFINITIONS

4 Impeded egress zone means a supervised area in which occupants have free movement but require the release, by security personnel, of security doors at the boundary before being able to leave the area, but does not include a contained use area.obc Smoke alarm means a combined smoke detector and audible alarm device designed to sound an alarm within the room orsuite in which it is located on the detection of smoke within that room or suite. Smoke detector means a fire detector designed to operate when the concentration of airborne combustion products exceeds a predetermined level. DEFINITIONS

5 Except as permitted by Sentence (6), if there are openings through a firewall, other than those for piping, tubing, wiring and totally enclosed noncombustible raceways, the requirements in this Subsection shall apply to the floor areas on both sides of the firewall as if they were in the same building. (6) Buildings interconnected by walkways permitted in Articles and or by vestibules provided in conformance with Article shall be treated as separate buildings for the purpose of fire alarm installation required by this Subsection TYPE: Single stage required in schools except in special needs facilities There is no definition of what a special needs facility is (2)(c) Appendix note: Alert signals are permitted to sound in designated areas. Permits use of a key or other similar device to activate alarm signals form a manual pull station OBC: THINGS YOU MAY NOT KNOW

6 (3) coded 2 stage systems are permitted to sound the alert tone only in the zone of initiation. The code must be repeated 4 times then a continuous alert signal is to sound in the zone of activation The entire fire alarm system is to be commissioned as a whole and test records provided indicating the integrated test was conducted Automatic silence IS allowed: 1 minute in care and treatment (alert signal only); 5 minutes in buildings not required to have an annunciator; 20 minutes in all other cases. A manual silence switch is ok, but only if installed inside the control unit OBC: THINGS YOU MAY NOT KNOW

7 Signals to FD. In a group C retirement home, regardless if monitoring is required, if there are sprinkler water flow switches, then you MUST connect them to the FD If a single stage system is provided in a building and the building is not sprinklered, then signs have to be installed above each manual pull station indicating that the fire department has to be called and indicating the phone number to call OBC: THINGS YOU MAY NOT KNOW

8 Annunciator and Zoning: Separate zones for: fire extinguishing systems required by NFPA 96, contained use areas, impeded egress zones, 2 hour fire resistance rated fire compartments If no annunciator is required, a visual and audible trouble signal device is required at the main entrance. If a silence switch is provided, and it s in a hotel, then a trouble signal also has to be installed at the main reception or other continually staffed location OBC: THINGS YOU MAY NOT KNOW

9 electrical supervision: standpipe water control valves only have to send a trouble signal to the annunciator and not a supervisory alarm. Heat tracing cable for sprinkler/standpipe or to keep an exit or means of egress free from ice to be monitored for loss of power; OBC: THINGS YOU MAY NOT KNOW

10 fire detectors are required in hazardous classrooms and change rooms in elementary and secondary schools. BUT post secondary schools are not mentioned smoke detectors are required in contained use areas AND the corridors serving these rooms and areas. OBC: THINGS YOU MAY NOT KNOW

11 Smokes are required in each elevator machine room or machinery space ( this could include the interstitial space between the top of the elevator shaft and the elevator machine room. NOTE: it does not say that smokes are required at the top of the shaft, or in the pits. Heat detectors can be installed at the top of the shaft. The code is silent about any device in the pit of elevators and escalators. OBC: THINGS YOU MAY NOT KNOW

12 Hotel refrigerated areas do not require heat detectors but in all other occupancies refrigerated areas do require heat detectors and are considered storage spaces (unless the spaces are sprinklers) OBC: THINGS YOU MAY NOT KNOW

13 Care and treatment facilities: smoke detectors in rooms are to cause an audible and visual signal to activate outside the room if staff can see all rooms from their station if not then a signal has to go to the main nursing station. OBC: THINGS YOU MAY NOT KNOW

14 Only the elevators controlled by the machine room where the smoke detector activated are required to recall. Smoke detectors can be substituted for heat detectors in F occupancies where they are subject to false alarms due to activities in the building NOTE: Nowhere does it mention in the smoke detector section that smoke detectors are required to be installed in computer room subfloors. ULC standards require smoke detectors to be installed pendent as they are tested and listed in this manner OBC: THINGS YOU MAY NOT KNOW

15 central vac required to shut down on fire alarm haven t seen a single one of these in 27 years yet the code doesn t regulate connection of sub panels for computer rooms which I see in every building elevator recall. Smokes required on unsprinklered recall levels in buildings provided with emergency recall feature. This should be in the smoke detector section OBC: THINGS YOU MAY NOT KNOW

16 manual pull stations. Required in: Principal entrance to a building; near every REQUIRED exit (not every exit from a building only the required ones); main reception areas of hotels require a manual pull station. (6) in a C occupancy, if a MPS is not installed per 1 and 4, then a MPS is required in each dwelling unit near the egress; smoke detectors are required to be installed in floor areas, public corridors and stairwells, and fire detectors installed in the floor area common areas and in rooms not located within dwelling units. Why are there smoke detector requirements in the manual pull station section of 3.2.4? OBC: THINGS YOU MAY NOT KNOW

17 If MPS are installed in dwelling units then signs are required to be installed above MPS in floor areas having them reading FIRE ALARM PULL STATION LOCATED IN APARTMENT UNITS Keyswitch MPS are permitted in contained use areas. Required to be listed. OBC: THINGS YOU MAY NOT KNOW

18 Alert and Alarm Signals (1) the same audible signal devices are permitted to sound alert and alarm signals (this is a permissive statement not a prescriptive statement) and implies different devices are permitted to sound alert and alarm signals (2) speakers are ok to use for other purposes but not allowed for background noise or music. Alert and alarm tones always have to take priority (3)(c) this has always confounded me: In a corridor used by the public and in a floor area or part of it where the public may congregate in a Group A occupancy. OBC: THINGS YOU MAY NOT KNOW

19 (5) The only exemption in the entire code that allows audible signalling devices to be deleted and replaced with visual signalling devices: in areas regulated by such as operating rooms, recovery rooms, delivery rooms, intensive care units and critical care units in special care and treatment facilities. So you can stop asking now. OBC: THINGS YOU MAY NOT KNOW

20 Audibility Alarm signal dbs to be attained throughout all floor areas. Alert signals are required to be audible in continually staffed locations. MUST USE AN INTEGRATING SOUND LEVEL METER FOR ANY TONE OTHER THAN TEMPORAL (this means for every alert signal tone in a two stage system). For temporal, a non-integrating sound level meter is to be used. OBC: THINGS YOU MAY NOT KNOW

21 : Alarm signals are regulated (temporal) but alert signals are not. The appendix note states that there must be a noticeable or a measurable difference between alert and alarm signals to reduce confusion. For some reason the slow whoop is used more often than not for alert signals. Exception for residential occupancies: Appendix note says if putting horns in corridors and the 100 bda wil be exceeded in an attempt to achieve 75 dba in sleeping areas then piezo electric devices similar to smoke alarm sounding devices can be installed if they are provided with the temporal pattern. This makes it sound like a smoke alarm and not a building audible signalling device. This clause appears to allow different sounding devices. OBC: THINGS YOU MAY NOT KNOW

22 Smoke alarms. Smoke detectors are allowed to replace smoke alarms and do not need to send a signal to the fire department and only sound within the suite of origin. Sound pressure levels: max of 100 but this can be exceeded if the max of 100 is never exceeded measured at 2 m above the finished floor. Measurements to be 3 m from the device. Minimum 65dbA, 3 m from device, AND 10 db above ambient noise. OBC: THINGS YOU MAY NOT KNOW

23 The voice comm system can silence the alert signals: after 10 s in hospitals, 30 seconds in all other cases. 30 seconds for alarm signals in a single stage system (7) if the occupant load is over 1000, AND a two stage system is provided, then a voice communication system must be provided. This will reduce the use of two stage systems. (9) if trained staff are not present at all times then digital voice messages MUST be used OBC: THINGS YOU MAY NOT KNOW

24 (8) In a Group B, Division 3 occupancy that contains sleeping accommodation for not more than 10 persons and not more than six occupants require assistance in evacuation in case of an emergency and which is equipped with a fire-alarm system, a duct need not be provided with a fire damper at a fire separation provided duct-type smoke detectors have been installed to control smoke circulation as described in Article (2) Except as required by Sentences (3), (5), (6) and (7), a hold-open device permitted by Sentence (1) shall be designed to release by a signal from, (a) an automatic sprinkler system, (b) a heat-actuated device, (c) fusible link, or (d) a smoke detector located as described in CAN/ULC-S524, Installation of Fire Alarm Systems : THIS IS NOT THE ONLY FIRE ALARM SECTION

25 (3) Except as required by Sentences (4), (5), (6) and (7), a holdopen device permitted by Sentence (1) shall be designed to release upon a signal from a smoke detector located as described in CAN/ULC-S524, Installation of Fire Alarm Systems, if used on, (e) a door required to function as part of a smoke control system. (5) Sentences (2) and (3) do not apply in a hospital or long-term care home to, (a) a door located between a corridor used by the public and an adjacent sleeping room, or (b) paired doors described in Sentence (4) : THIS IS NOT THE ONLY FIRE ALARM SECTION

26 Fire stopping is not required for sprinkler pipes that are provided with escutcheon plates per NFPA : THIS IS NOT THE ONLY FIRE ALARM SECTION

27 In buildings not required to be sprinklered, the basements shall be sprinklered or subdivided into 600 m 2 fire compartments that are required to be rated per the floor above. This can mean that they will be required to be separately zoned requires smoke barrier doors in underground walkways but if held open, they would be regulated and require smoke detectors for release 3.2.4: THIS IS NOT THE ONLY FIRE ALARM SECTION

28 (5) in an unsprinkered building with the recall feature, smokes are required in each elevator lobby on each level smokes required on the ceiling of each storey in the vicinity of the openings through floor assemblies. Smokes are also to be provided where required for the activation of the smoke control system. ( system activated when two smokes in a single zone in a floor area having an interconnected floor space are activated.) 3.2.4: THIS IS NOT THE ONLY FIRE ALARM SECTION

29 (14)(e) : Aisles fire detectors are to shut down projection systems and turn on normal lighting in seating areas (14)(g) Smoke detectors in seating areas are to activate smoke evacuation system for seating areas 3.2.4: THIS IS NOT THE ONLY FIRE ALARM SECTION

30 (4) fire curtains are to close on activation of the FAS and heat actuated devices (5) smoke vents are to activate automatically upon operation of the sprinkler system. This is only done via the FAS maglocks are permitted to release on second stage only in care/treatment/detention occupancies 3.2.4: THIS IS NOT THE ONLY FIRE ALARM SECTION

31 maglocks are permitted to release on second stage only in care/treatment/detention occupancies (7) gaming premises are to have smoke detectors in each room and corridor accessible by the public when maglocks are installed in the building. This applies even if it s a single maglock : THIS IS NOT THE ONLY FIRE ALARM SECTION

32 (2) smoke detectors are required in an electrical vault if the building is required to be sprinklered and sprinklers were omitted from the vault : THIS IS NOT THE ONLY FIRE ALARM SECTION

33 Rapid transit stations: (1) MPS are not required. Audible signal devices are not required. (3) fire detectors are required in service rooms, ancillary spaces, leased spaces, booths and kiosks. (5) an annunciator is required in a designated collection booth or within viewing distance of the booth (6) all fire detectors are to be annunciated. This means system must be addressable. If a RTS exit is through another building, then the bulding above must be annunciated on the RTS annunciator and a flashing warning sign is required at the entrance to the building 3.2.4: THIS IS NOT THE ONLY FIRE ALARM SECTION

34 ULC S524 Applies to voluntary and required fire alarm systems What is a fire alarm system: An interconnected control unit, manual station and audible signal device ULC S524 AND S537

35 cannot use a voice communication system in lieu of alert and alarm signals, only supplement those signals s response time for single stage systems, alarm signals, auxiliary function operation but 90 seconds for trouble input response time Special note: 3: manual control of paging and alarm selection to confirm output operation with sensory indication to the operator within 1 second that the function has been requested. ULC S524 AND S537

36 (m). only need to connect genset for common trouble to FAS when the genset is the sole source of emergency power. ULC S524 AND S537

37 Class A system: can have a single conduit for feed and return run when serving a single device or when serving multiple devices in a room not exceeding 100 sq m wiring between control units and transponders within the same room are not required to be supervised if in EMT and less than 18m apart 3.5 Plan and specs : input output schedule; sew of op; zoning, device addresses, fault isolation module locations, ancilliary device connection, block wiring diagram showing all interconnections of control equipment and devices ULC S524 AND S537

38 4.1 operating and controls not more than 1.8 m above finished floor 4.2 data communication links: Style C DCL does not require detection of a single ground. (input circuit transmits ground and second ground doesn t disable the DCL loop loading: conventional field devices monitored by a supporting field device do not count against DCL capacity ULC S524 AND S537

39 area of coverage for inputs and outputs to be the same for transponders but only in large scale networks. ULC S524 AND S537

40 4.3 Large scale networks when multiple faults cause the network to be severed, it is intended for each portion of the network to function as intended within the capabilities of each section 4.3.6: at least one field control panel or transponder, in addition to the CACF/DCC/ANN required by the NBC, requires a paging microphone, an NBC conforming ANN, and an All call switch. ULC S524 AND S537

41 Transponders required to be located in a 1 hour rated room (this is above the NBC requirements and should be regulated by the NBC) conductors to interconnect transponders/control equipment to be fire rated for 1 hour or installed in 2 physically separated 1 hour rated compartments Voice communication busses don t require supervision during use but do during times when the bus is being used for non fire safety purposes (ie. General paging). Single ground detection not required on the voice communication buss ULC S524 AND S537

42 manual pull stations should be on the latch side but nevertheless within 1500 mm max lateral distance from the opening top of audible signalling devices not less than 2.3 m above the finished floor and 150mm below the ceiling Audible signalling devices shall generate similar sounds and sound patterns when activated. ULC S524 AND S537

43 mm clear space required around all fire detectors unless detectors obstructions are less than 100mm deep and 450 mm away from air diffusers. If partitions extend within 450 mm of ceiling then special spacing requirements are applicable if fire detectors are subjected to positive and negative air flow, a special plate is required or conduits/entry points have to be sealed. ULC S524 AND S537

44 Heat detector spacing requirements are NOT applicable to smoke detectors. heat detectors do not get installed on ceilings higher than 9 m. smoke detectors on ceilings above 3.6 m, require engineering judgement Smoke detectors on every 3 rd floor if building is over 18m. This should be in the OBC. ULC S524 AND S537

45 Smoke detectors can be substituted with fixed temperature heat detectors due to low ambient temperatures, below 0 degrees C, 5.14 fault isolation modules see standards bulletin : fault isolation modules not required on both sides of fire separations unless they are required zones under the NBC. ULC S524 AND S537

46 A2.1: special spacing requirements for thermal stratification (skylights and large glass areas) A5: check it out for smoke detector use for door release. One smoke required if any area above the door is 600 mm or less (swing side of door). Greater than 600mm both sides then one smoke on each side. Door frame mounting requires one smoke detector. Install centre line and not closer than 300 mm when corridors less than 1500mm, and 600 mm in all other cases. ULC S524 AND S537

47 ULC S537 Bulletin : all devices need to be re-verified after a program/software change if a LISTED compare program is not used. No manufacturers currently have a listed compare program. Bulletin when a 4 th party is required to conduct the verification ULC S524 AND S537

48 3.1.3 each device to be tested. This means that line isolators have to be tested and documented. 3.2 Documentation: seq of op and operating instructions to be documented in test documents field devices at the electrically furthest point from the power source to be tested that it receives rated power. This I have never seen documented in any verification records I have ever seen. ULC S524 AND S537

49 and 4,2,1,4 a printout of active field device software correlation report is to be provided as part of the verification. If the report can t be printed, EVERY device has to be tested to confirm the correct output circuit operation. Again, I have never seen this done system response times to be tested and recorded NOT JUST sprinkler device delay times ULC S524 AND S537

50 If multiple annunciators or sequential displays, each must be checked for alarm and supervisory operation and zone annunciation, unless proven with a software compare program (must be listed) or manufacturers technical documentation. Has anyone ever seen this submitted with a verification? 4.6 Every printer has to be tested to ensure it printed correctly 5.10.(c) Audibility of alert and alarm signals to be tested. ULC S524 AND S537

51 6.4 If wiring extended form a junction box, every device on the circuit has to be reverified. ULC S524 AND S537

52 Raise your hand if you re still awake THANK YOU.

53 THANK YOU.

54 Paul Latreille, CET QUESTIONS?

55

FLORIDA ATLANTIC UNIVERSITY FIRE ALARM SYSTEM INSTALLATION MANUAL

FLORIDA ATLANTIC UNIVERSITY FIRE ALARM SYSTEM INSTALLATION MANUAL FLORIDA ATLANTIC UNIVERSITY FIRE ALARM SYSTEM INSTALLATION MANUAL January, 2003 Environmental Health and Safety Florida Atlantic University 777 Glades Rd. Boca Raton, FL 33431 Phone: 561-297-3129 Fax:

More information

2012 Ontario Building Code Changes Affecting Fire Alarm Systems

2012 Ontario Building Code Changes Affecting Fire Alarm Systems 2012 Ontario Building Code Changes Affecting Fire Alarm Systems CFAA Annual Technical Seminar May 31, 2013 Ken Baird VP Systems www.lrifire.com LRI 2010 Developments in Life Safety Introduction Code Development

More information

FIRE RATED WIRING. What the FT4! Paul Latreille, C.E.T. Ottawa Branch Manager

FIRE RATED WIRING. What the FT4! Paul Latreille, C.E.T. Ottawa Branch Manager FIRE RATED WIRING What the FT4! Paul Latreille, C.E.T. Ottawa Branch Manager INTRODUCTION OBC requirements for emergency power OBC requirements for emergency power for fire alarm systems and other building

More information

City of Bettendorf Fire Alarm System Requirements

City of Bettendorf Fire Alarm System Requirements City of Bettendorf Fire Alarm System Requirements Section 907 of the 2009 Edition of the International Fire Code (IFC) and Section 10-7-3 of the Municipal Code provide fire alarm requirements. IFC Section

More information

TAMARAC FIRE RESCUE INSTRUCTIONS FOR FIRE ALARM PRE-SUBMITTAL CHECKLIST

TAMARAC FIRE RESCUE INSTRUCTIONS FOR FIRE ALARM PRE-SUBMITTAL CHECKLIST TAMARAC FIRE RESCUE INSTRUCTIONS FOR FIRE ALARM PRE-SUBMITTAL CHECKLIST In order to provide a comprehensive plan review in a timely manner, and to insure the design and installation of fire alarm systems

More information

CITY OF PHILADELPHIA DEPARTMENT OF LICENSES AND INSPECTIONS ANNUAL CERTIFICATION FOR FIRE ALARM SYSTEMS

CITY OF PHILADELPHIA DEPARTMENT OF LICENSES AND INSPECTIONS ANNUAL CERTIFICATION FOR FIRE ALARM SYSTEMS CITY OF PHILADELPHIA DEPARTMENT OF LICENSES AND INSPECTIONS ANNUAL CERTIFICATION FOR FIRE ALARM SYSTEMS PROPERTY ADDRESS (BRT Address Required) TESTING CONTRACTOR (Name and Address) License No. ANNUAL

More information

DTW Works Master Specification Version 2006

DTW Works Master Specification Version 2006 Issued 2006/08/01 Section 13852 Multiplex Fire Alarm System Page 1 of 10 PART 1 GENERAL 1.1 RELATED WORK.1 Section 01330 Submittal Procedures..2 Section 01780 Closeout Procedures..3 Section 01810 Commissioning..4

More information

CBD-233. Fire Alarm and Detection Systems

CBD-233. Fire Alarm and Detection Systems Page 1 of 5 CBD-233. Fire Alarm and Detection Systems Originally published August 1984. R.H.L. McEwen Fire alarm systems are normally required by building codes. In the case of new buildings, this is usually

More information

Fire Alarm System Plans Submittal Guidelines For New and Existing Systems

Fire Alarm System Plans Submittal Guidelines For New and Existing Systems Fire Alarm System Plans Submittal Guidelines For New and Existing Systems SCOPE The Temecula Fire Prevention Bureau (TFPB) has established the following requirements for the submittal of all fire alarms,

More information

PARTICIPATION HOUSE 9 BUTTERNUT LANE, MARKHAM

PARTICIPATION HOUSE 9 BUTTERNUT LANE, MARKHAM PARTICIPATION HOUSE 9 BUTTERNUT LANE, MARKHAM B 3 CASE STUDY RANDAL BROWN & ASSOCIATES ENGINEERING LTD. CONSULTING ENGINEERS LIFE SAFETY & FIRE PROTECTION 105 6 LANSING SQUARE TORONTO, ONTARIO PARTICIPATION

More information

Fire Alarm System Plans Review Checklist Property location Date of Review

Fire Alarm System Plans Review Checklist Property location Date of Review Fire Alarm System Plans Review Checklist Property location Date of Review 1. Is application completed in entirety? 2. Are the plans review fee submitted with the application? 3. Does floor plan include

More information

PLAN REVIEW GUIDE FOR FIRE ALARM

PLAN REVIEW GUIDE FOR FIRE ALARM PLAN REVIEW GUIDE FOR FIRE ALARM PROJECT NAME: PERMIT # PROJECT ADDRESS: CONTACT PERSON: PHONE Fire alarm system installation information shall be provided on the appropriate architectural and electrical

More information

Bold items are particular to the City of Euless

Bold items are particular to the City of Euless EULESS FIRE DEPARTMENT FIRE MARSHAL S OFFICE INFORMATION LINE: Revised 2/12 Fire Chief Wes Rhodes Fire Marshal Paul Smith EFD-FMO 3-2 2009 International Fire & Building Code as Amended NFPA Standards Adopted

More information

FIRE CODE INTERPRETATION

FIRE CODE INTERPRETATION FIRE CODE INTERPRETATION March 2008 ISSUE: Existing Fire Alarm Systems FCI-08-06 Page 1 of 9 The purpose of this bulletin is to identify conditions where a building fire alarm system may be subject to

More information

Life Safety Code Enabling References

Life Safety Code Enabling References SUPPLEMENT 4 Life Safety Code Enabling References Editor s Note: Supplement 4 provides users of NFPA 72, National Fire Alarm and Signaling Code, with a summary of requirements from NFPA 101, Life Safety

More information

University Design Standard. Fire Alarm Systems

University Design Standard. Fire Alarm Systems University Design Standard Fire Alarm Systems 1.0 Overview This document provides Virginia Tech s standards for the design and installation of fire alarm systems and equipment in new construction, retrofit

More information

FIRE DETECTION AND ALARM

FIRE DETECTION AND ALARM Scope Provide a fire alarm system, or expand the existing system, as required by Code, the requirements in the Special Instructions to Designers (SID) of the Design Guidelines, and/or as noted in the Program

More information

BS5839 Part 1:2002 Overview

BS5839 Part 1:2002 Overview BS5839 Part 1:2002 Overview 1 Contents Introduction So why is the current standard being revised? The brief for the new standard Changes to structure of current Standard Enhanced certification of Fire

More information

OBOA 2009 Huntsville, ON Overview of ULC Standards Affecting Building Occupancy Alan Cavers Area Manager Fire & Security Systems Group

OBOA 2009 Huntsville, ON Overview of ULC Standards Affecting Building Occupancy Alan Cavers Area Manager Fire & Security Systems Group OBOA 2009 Huntsville, ON Overview of ULC Standards Affecting Building Occupancy Alan Cavers Area Manager Fire & Security Systems Group Course Title: Rev Date Agenda Introduction to Underwriters Laboratories

More information

FIRE-FIGHTING DESIGN BRIEF REPORT

FIRE-FIGHTING DESIGN BRIEF REPORT P a g e 1 SECTION 04 (Doc.No.A/DBR 001) FIRE-FIGHTING DESIGN BRIEF REPORT P a g e 2 1.0 SCOPE 2.0 STANDARDS AND CODES 3.0 TYPES OF SYSTEM PROPOSED 4.0 FIRE HYDRANT SYSTEM 5.0 AUTOMATIC SPRINKLER SYSTEM

More information

CLARK COUNTY FIRE DEPARTMENT Fire Hazard & Prevention Services

CLARK COUNTY FIRE DEPARTMENT Fire Hazard & Prevention Services CLARK COUNTY FIRE DEPARTMENT Fire Hazard & Prevention Services 575 E. Flamingo Road, Las Vegas, NV 89119 (702) 455-7316 FAX (702) 455-7347 105.8a-6.1 TITLE: FIRE ALARM SYSTEM REQUIREMENTS SCOPE: This guideline

More information

Fire. The Fire Installers Mate. A guide to fire alarm systems design

Fire. The Fire Installers Mate. A guide to fire alarm systems design Fire The Fire Installers Mate A guide to fire alarm systems design BS 5839 Part 1:2002 A guide to BS 5839 Part 1:2002 Disclaimer This booklet is not intended to be a comprehensive guide to all aspects

More information

SECTION 16720 - FIRE AND SMOKE ALARM SYSTEM. City of San Diego, CWP Guidelines

SECTION 16720 - FIRE AND SMOKE ALARM SYSTEM. City of San Diego, CWP Guidelines PART 1 -- GENERAL 1.1 WORK OF THIS SECTION SECTION 16720 - City of San Diego, CWP Guidelines A. The WORK of this Section includes providing manual and automatic fire alarm and smoke detection systems meeting

More information

AVAILABLE TO DOWNLOAD ON THE APOLLO APP. Fire Alarm Systems Design. a guide to BS5839

AVAILABLE TO DOWNLOAD ON THE APOLLO APP. Fire Alarm Systems Design. a guide to BS5839 AVAILABLE TO DOWNLOAD ON THE APOLLO APP a guide to Fire Alarm Systems Design BS5839 Part1:2013 The Regulatory Reform (Fire Safety) Order (FSO) became law on 1 October 2006 Legally you must comply! What

More information

General Safety & Health Standards Published by the Division of Building Safety In Cooperation with the Idaho Industrial Commission

General Safety & Health Standards Published by the Division of Building Safety In Cooperation with the Idaho Industrial Commission General Safety & Health Standards Published by the Division of Building Safety In Cooperation with the Idaho Industrial Commission Local Fire Alarm 064. FIRE ALARM SYSTEMS 01. Scope 02. Definitions 03.

More information

Design Standards Fire Alarm Systems Division 13860 (1995 CMS); 283100 (2004 CMS) Amended Feb 2015

Design Standards Fire Alarm Systems Division 13860 (1995 CMS); 283100 (2004 CMS) Amended Feb 2015 Design Standards Fire Alarm Systems Division 13860 (1995 CMS); 283100 (2004 CMS) Amended Feb 2015 13860 (283100) FIRE ALARM SYSTEM The following standard shall be followed for the design of University

More information

2007 ICC FINAL ACTION AGENDA

2007 ICC FINAL ACTION AGENDA 907.2.1.1 System initiation in Group A occupancies with an occupant load of 1,000 or more. Activation of the fire alarm in Group A occupancies with an occupant load of 1,000 or more shall initiate a signal

More information

SECTION 16721 FIRE ALARM AND DETECTION SYSTEM

SECTION 16721 FIRE ALARM AND DETECTION SYSTEM 1. GENERAL 1.1. Related Documents: 1.2. Scope: 1.1.1. The general provisions of the Contract, including General and Supplementary Conditions and General Requirements apply to the work specified in this

More information

Module 5. Fire and Emergency Alarm System Part I- Basics

Module 5. Fire and Emergency Alarm System Part I- Basics Module 5 Fire and Emergency Alarm System Part I- Basics 1 This module will describe: 1. Components and the arrangements of components in fire and emergency alarm systems. 2. How these systems work. 3.

More information

NFPA 72. Exception No. 1: Where ambient conditions prohibit installation of automatic smoke detection, automatic heat detection shall be permitted.

NFPA 72. Exception No. 1: Where ambient conditions prohibit installation of automatic smoke detection, automatic heat detection shall be permitted. NFPA 72 3.3.7.2 3.3.7.2 False Alarm. Activation or reporting of an alarm for which no such alarm condition, fire or emergency actually exists. Additionally, False Alarm is the willful and knowing initiating

More information

HERNANDO COUNTY FIRE ALARM GUIDELINES

HERNANDO COUNTY FIRE ALARM GUIDELINES HERNANDO COUNTY FIRE ALARM GUIDELINES To be used for all commercial building fire alarm system plan review. The procedures set forth in this document are the minimum requirements necessary to ensure a

More information

FIRE ALARM SYSTEM. A. Shop drawings shall be submitted as follows: 1. Manufacturer's published literature. for aspproval.

FIRE ALARM SYSTEM. A. Shop drawings shall be submitted as follows: 1. Manufacturer's published literature. for aspproval. Polk School District Specifications for the New Fire Alarm in the Existing Building Eastside Elementary School FIRE ALARM SYSTEM 1.01 SUBMITTALS A. Shop drawings shall be submitted as follows: 1. Manufacturer's

More information

CAN/ULC-S524-06 Installation of Fire Alarm Systems Amendment 1. Canadian Fire Alarm Association (CFAA) D. GOODYEAR FIRE CONSULTING

CAN/ULC-S524-06 Installation of Fire Alarm Systems Amendment 1. Canadian Fire Alarm Association (CFAA) D. GOODYEAR FIRE CONSULTING CAN/ULC-S524-06 Installation of Fire Alarm Systems Amendment 1 Canadian Fire Alarm Association (CFAA) CAN/ULC-S524 AMENDMENT 1 PUBLISHED February 2011 WHY Clarifications New requirements (Technology changes)

More information

Telluride Fire Protection District Fire Alarm Systems Policy Version 03/2007

Telluride Fire Protection District Fire Alarm Systems Policy Version 03/2007 Telluride Fire Protection District Fire Alarm Systems Policy Version 03/2007 FIRE ALARM SYSTEMS POLICY TELLURIDE FIRE PROTECTION DISTRICT TABLE OF CONTENTS FIRE ALARM PROTECTION POLICY PLAN REVIEW SUBMITTAL

More information

Module 4, Lesson 12 Fire Alarm Systems

Module 4, Lesson 12 Fire Alarm Systems Student Manual Module 4, Lesson 12 Fire Alarm Systems Performance Objectives At the conclusion of this lesson, you will be able to: Identify the components and functions of a fire alarm system and determine

More information

CHAPTER 9 FIRE PROTECTION SYSTEMS

CHAPTER 9 FIRE PROTECTION SYSTEMS CHAPTER 9 FIRE PROTECTION SYSTEMS SECTION 901 GENERAL 901.1 Scope. Provisions of this chapter shall govern the application, design, installation, testing and maintenance of automatic sprinklers, standpipes

More information

BUILDING OWNERS - SERVICE RELATED ISSUES FOR FIRE ALARM SYSTEMS

BUILDING OWNERS - SERVICE RELATED ISSUES FOR FIRE ALARM SYSTEMS BUILDING OWNERS - SERVICE RELATED ISSUES FOR FIRE ALARM SYSTEMS Owners have numerous responsibilities as it pertains to the maintenance and operation of a building s fire safety equipment. The liabilities

More information

We hope these Frequently Asked Questions will be of use both to municipal officials and fire inspectors.

We hope these Frequently Asked Questions will be of use both to municipal officials and fire inspectors. September 14, 2012 Dear AMM Member: Please see the attached Fire Code Frequently Asked Questions. This document was compiled by the Office of the Fire Commissioner at the AMM s request to help clarify

More information

MINIMUM STANDARDS FOR HIGH-RISE BUILDINGS

MINIMUM STANDARDS FOR HIGH-RISE BUILDINGS CHAPTER 93 MINIMUM STANDARDS FOR HIGH-RISE BUILDINGS Note: Chapter 93 is entirely Seattle amendments to the International Fire Code and is not underlined. Point of Information The requirements of this

More information

SPECIAL RESIDENCE (ASSISTED SELF-PRESERVATION) OCCUPANCIES (Adopted by the State of Oregon)

SPECIAL RESIDENCE (ASSISTED SELF-PRESERVATION) OCCUPANCIES (Adopted by the State of Oregon) SPECIAL RESIDENCE (ASSISTED SELF-PRESERVATION) OCCUPANCIES (Adopted by the State of Oregon) SECTION SR101 GENERAL SR101.1 General. Group SR occupancies shall comply with the provisions of this appendix

More information

Name Of Occupancy Date. Yes No Describe

Name Of Occupancy Date. Yes No Describe FIRE PREVENTION INSPECTION CHECKLIST For Class A Occupancy (For Assembly Buildings, Bars, Restaurants, Gyms, Churches, Arenas, Theatres or wherever people gather) Name Of Occupancy Date Physical Address

More information

FIRE ALARM SYSTEM SUBMITTAL CHECKLIST AND APPLICATION

FIRE ALARM SYSTEM SUBMITTAL CHECKLIST AND APPLICATION PERMITS AND INSPECTIONS FIRE ALARM SYSTEM SUBMITTAL CHECKLIST AND APPLICATION 911 Assigned PROJECT LOCATION Subdivision: Lot: Blk: Sec: PROJECT New Construction Addition/Remodel Demolition Other: Number

More information

SECTION 16721 FIRE ALARM AND DETECTION SYSTEMS

SECTION 16721 FIRE ALARM AND DETECTION SYSTEMS SECTION 16721 FIRE ALARM AND DETECTION SYSTEMS The equipment requirements of this section apply to the IUB Campus. The IUPUI Campus has a preferred vendor agreement for fire alarm systems. Contact Pat

More information

FIRE ALARM SYSTEM RECORD OF COMPLETION

FIRE ALARM SYSTEM RECORD OF COMPLETION FUNDAMENTALS OF FIRE ALARM SYSTEMS 72 33 FIRE ALARM SYSTEM RECORD OF COMPLETION To be completed by the system installation contractor at the time of system acceptance and approval. 1. PROTECTED PROPERTY

More information

FIRE ALARM SYSTEM RECORD OF COMPLETION

FIRE ALARM SYSTEM RECORD OF COMPLETION FIRE ALARM SYSTEM RECORD OF COMPLETION To be completed by the system installation contractor at the time of system acceptance and approval. 1. Protected Property Information Name of property: Description

More information

CHANGES IN NFPA 72 NATIONAL FIRE ALARM CODE 1999 2002

CHANGES IN NFPA 72 NATIONAL FIRE ALARM CODE 1999 2002 CHANGES IN NFPA 72 NATIONAL FIRE ALARM CODE 1999 2002 Three new chapters were added. What was chapter 1 in 1999 was reorganized into chapters 1 (Fundamentals), 2 (Referenced Publications), and 3 (Definitions).

More information

Fire Alarm System Monitoring - CAN/ULC-S561-03

Fire Alarm System Monitoring - CAN/ULC-S561-03 Fire Alarm System Monitoring - CAN/ULC-S561-03 Brian McBain ULC Regulatory Services May 4, 2011 Copyright 1995-2007 Underwriters' Laboratories of Canada. All rights reserved. No portion of this material

More information

Rancho Cucamonga Fire Protection District Prevention Bureau Standard

Rancho Cucamonga Fire Protection District Prevention Bureau Standard Rancho Cucamonga Fire Protection District Prevention Bureau Standard Title: Fire Alarm and Monitoring Systems Standard # 9-3 Effective: May 2002 Number of Pages: 7 Revised: January 2014 INTENT The intent

More information

FIRE ALARM PLAN REVIEW. Office of the State Fire Marshal Massachusetts Department of Fire Services December 2009

FIRE ALARM PLAN REVIEW. Office of the State Fire Marshal Massachusetts Department of Fire Services December 2009 FIRE ALARM PLAN REVIEW Office of the State Fire Marshal Massachusetts December 2009 SURPRISE QUIZ 1. A fire alarm system is required to be installed by the MSBC, what edition of NFPA 72 do you use? 2.

More information

Sprinkler and Fire Alarm Systems for the Building Official

Sprinkler and Fire Alarm Systems for the Building Official Sprinkler and for the Building Official Randall Kovacs, P.Eng., CP, FEC Gage-Babcock & Associates, Ltd. Topics Coordinated System Testing 1 Wet Dry Pre-action Deluge Wet System: Pipes filled with water

More information

Interfacing Elevators with Fire Alarm and Sprinklers

Interfacing Elevators with Fire Alarm and Sprinklers Interfacing Elevators with Fire Alarm and Sprinklers IEEE Atlanta Chapter May 15, 2006 Brian K Fabel, PE Agenda Today s Codes NFPA, ASME, IBC/IFC Conflicts/Issues Tomorrow s Codes? Applicable Codes NFPA

More information

3.2.4.8.(1) Signals to Fire Department A new requirement inserted due to a new defined use for Group C retirement homes.

3.2.4.8.(1) Signals to Fire Department A new requirement inserted due to a new defined use for Group C retirement homes. Backgrounder: Fire Alarm related 2012 Code changes (Information obtained from the MMAH Consultation for Potential Changes for the next edition of the Building Code, October November 2010) 3.2.4.2.(6) -

More information

SECTION 16721 FIRE ALARM AND SMOKE DETECTION SYSTEMS

SECTION 16721 FIRE ALARM AND SMOKE DETECTION SYSTEMS SECTION 16721 PART 1 - GENERAL 1.1 SECTION INCLUDES A. Fire Alarm Control Panels B. Manual Fire Alarm Stations C. Automatic Smoke D. Fire Alarm Notification Appliances E. Auxiliary Fire Alarm Equipment

More information

BUILDING DESIGN STANDARDS UNIVERSITY SERVICES ELECTRONIC SAFETY AND SECURITY - DIVISION 28 Fire Alarm Systems 28 31 01

BUILDING DESIGN STANDARDS UNIVERSITY SERVICES ELECTRONIC SAFETY AND SECURITY - DIVISION 28 Fire Alarm Systems 28 31 01 Part 1 General 1.1 Summary.1 NOTIFIER is the sole source supplier for McGill fire alarm systems, whether for replacements, modifications or new designs. All following guidelines apply..2 In general, follow

More information

Overview of Hotel Fire Safety Requirements

Overview of Hotel Fire Safety Requirements Overview of Hotel Fire Safety Requirements in the Fire Code Susan Clarke, P.Eng. Office of the Fire Marshal - January 10, 2012 1 Agenda Regulation History - Hotels Fire Code Overview (Parts 1 to 8) Defined

More information

SARATOGA FIRE DISTRICT EARLY WARNING FIRE ALARM SYSTEM STANDARDS AND REQUIRMENTS CONTENTS

SARATOGA FIRE DISTRICT EARLY WARNING FIRE ALARM SYSTEM STANDARDS AND REQUIRMENTS CONTENTS SARATOGA FIRE DISTRICT EARLY WARNING FIRE ALARM SYSTEM STANDARDS AND REQUIRMENTS CONTENTS I. APPLICATION AND DEFINITIONS 1.01 Authorization for Standards 1.02 Application of Standards 1.03 Definitions

More information

Mobile Fire Rescue Department Bureau of Fire Prevention

Mobile Fire Rescue Department Bureau of Fire Prevention 222 Mobile Fire Rescue Department Bureau of Fire Prevention Samuel L. Jones Mayor Stephen A. Dean Fire Chief February 2011 2009 International Fire Code Fire Alarm and Detection Systems 907.1 General. This

More information

Fire Alarm Engineering Best Practices. CFAA NCA Technical Seminar 2014

Fire Alarm Engineering Best Practices. CFAA NCA Technical Seminar 2014 Fire Alarm Engineering Best Practices CFAA NCA Technical Seminar 2014 2 Overview Code Compliance Equipment Selection and Layout Drawings, Specifications Commissioning and Acceptance Miscellaneous Goals

More information

Winnipeg Fire Department Fire Prevention Branch

Winnipeg Fire Department Fire Prevention Branch Winnipeg Fire Department Fire Prevention Branch Manitoba Fire Code Life-Safety Equipment Maintenance Requirements The Fire Prevention Branch of the Winnipeg Fire Department has prepared this document of

More information

527 CMR: BOARD OF FIRE PREVENTION REGULATIONS

527 CMR: BOARD OF FIRE PREVENTION REGULATIONS 527 CMR 24.00: FIRE WARNING SYSTEMS INSTALLED IN BUILDINGS WITHIN THE COMMONWEALTH OF MASSACHUSETTS Section 24.01: Purpose 24.02: Scope 24.03: Definitions 24.04: Approval of Design 24.05: Power Supply

More information

DELAWARE STATE FIRE MARSHAL FIRE ALARM SYSTEM CERTIFICATE OF INSTALLATION

DELAWARE STATE FIRE MARSHAL FIRE ALARM SYSTEM CERTIFICATE OF INSTALLATION Phone System Owner Phone System Engineered by: of Record Drawings: of System Manuals: of Test Reports: System Installer 1. GENERAL INFORMATION Phone Delaware License No: Certificate Holder No. System Supplier

More information

Proposed changes to the Acceptable Solution for Building Code clause F7 (Warning Systems) Proposed amended Acceptable Solution for Warning Systems

Proposed changes to the Acceptable Solution for Building Code clause F7 (Warning Systems) Proposed amended Acceptable Solution for Warning Systems Proposed changes to the Acceptable Solution for Building Code clause F7 (Warning Systems) Appendix A Proposed amended Acceptable Solution for Warning Systems s in the grey boxes form part of the proposed

More information

FIRE ALARM SYSTEM CHECKLIST For Addressable Systems PRIOR TO INSPECTION

FIRE ALARM SYSTEM CHECKLIST For Addressable Systems PRIOR TO INSPECTION Building Name/Location: Installing Company: Observation By: Date: Time: 1 Building Occupants, Authorities and Alarm Monitoring Co Have Been Notified 2 FACP Manufacturer and Panel is Approved for NCSU Campus

More information

Excerpts from the Canadian National Building Code (NBC)

Excerpts from the Canadian National Building Code (NBC) Excerpts from the Canadian National Building Code (NBC) Reproduced here with Permission of the Copyright Owner, the National Research Council of Canada, Institute for Research in Construction. For more

More information

CONSTRUCTION FIRE SAFETY PLANNING GUIDELINES

CONSTRUCTION FIRE SAFETY PLANNING GUIDELINES CONSTRUCTION FIRE SAFETY PLANNING GUIDELINES Review the following information pertaining to Construction Fire Safety Planning: B.C. Building Code Sections 8.1 up to and including Subsection 8.2.3 B.C.

More information

- 5 - Table1. Maximum Compartment Volumes

- 5 - Table1. Maximum Compartment Volumes - 5 - Part II - SPECIFIC REQUIREMENTS 5. Compartmentation 5.1 Every building should be divided into compartments by walls and floors to inhibit the spread of fire. 5.2 Compartment walls, compartment floors,

More information

CAN/ULC S1001-11 Integrated Systems Testing of Fire Protection and Life Safety Systems and Fire Protection Commissioning

CAN/ULC S1001-11 Integrated Systems Testing of Fire Protection and Life Safety Systems and Fire Protection Commissioning CAN/ULC S1001-11 Integrated Systems Testing of Fire Protection and Life Safety Systems and Fire Protection Commissioning Presentation To: Canadian Fire Alarm Association (CFAA) Alberta Technical Seminar

More information

ALBERTA FIRE CODE SAFETY EQUIPMENT MAINTENANCE REQUIREMENTS

ALBERTA FIRE CODE SAFETY EQUIPMENT MAINTENANCE REQUIREMENTS ALBERTA FIRE CODE SAFETY EQUIPMENT MAINTENANCE REQUIREMENTS In this document are the fire safety equipment maintenance requirements that are found in Division B of the Alberta Fire Code (AFC 2006) for

More information

Building Codes Update: The 2009 International Fire Code and the Apartment Industry

Building Codes Update: The 2009 International Fire Code and the Apartment Industry ! Building Codes Update: The 2009 International Fire Code and the Apartment Industry Apartment operators and developers should be aware of organizational changes in the 2009 edition of the International

More information

How To Install A Carbon Monoxide Detector

How To Install A Carbon Monoxide Detector NASSAU COUNTY FIRE COMMISSION OFFICE OF THE FIRE MARSHAL Nassau County Public Safety Center 1194 Prospect Avenue Westbury, New York 11590 (516) 573-9900 / nassaucountyny.gov Chief Fire Marshal Scott D.

More information

Fire Alarm System Monitoring, a Primer for the Property Owner David Duggan, 2005

Fire Alarm System Monitoring, a Primer for the Property Owner David Duggan, 2005 Fire Alarm System Monitoring, a Primer for the Property Owner David Duggan, 2005 Problem: How does a property owner / manager know when a fire alarm system is required for his premises, and just as important,

More information

Original Document 10/16/07 Revised 01/30/09 2 nd Revision 01-23-12 3 rd Revision- 12/18/14

Original Document 10/16/07 Revised 01/30/09 2 nd Revision 01-23-12 3 rd Revision- 12/18/14 North Collier Fire Control & Rescue District Greater Naples Fire Rescue District Immokalee Fire Control & Rescue District 2800 North Horseshoe Drive Naples, Florida 34104 SYSTEM REHABILITATION PLAN CHECKLIST

More information

NFPA 91 1999 Edition. 2.1.9 Fire dampers shall be permitted to be installed in exhaust systems in the following situations:

NFPA 91 1999 Edition. 2.1.9 Fire dampers shall be permitted to be installed in exhaust systems in the following situations: NFPA 91 1999 Edition 2.1.9 Fire dampers shall be permitted to be installed in exhaust systems in the following situations: 1) Where ducts pass through fire barriers (2) Where a collection system installed

More information

NATIONAL FIRE ALARM AND SIGNALING CODE

NATIONAL FIRE ALARM AND SIGNALING CODE GAP.11.1.1.0 A Publication of Global Asset Protection Services LLC NATIONAL FIRE ALARM AND SIGNALING CODE INTRODUCTION National Fire Protection Association (NFPA) documents describe a level of fire protection

More information

ENGINEERING SPECIFICATIONS

ENGINEERING SPECIFICATIONS ENGINEERING SPECIFICATIONS FM-200 CLEAN-AGENT FIRE SUPPRESSION SYSTEM with PYRO-CHEM DETECTION/RELEASE SYSTEM March 2001 SECTION 1 - GENERAL I. SCOPE This specification outlines the requirements for a

More information

FIRE DETECTION AND ALARM SYSTEMS

FIRE DETECTION AND ALARM SYSTEMS HMO Information Sheet No 1 FIRE DETECTION AND ALARM SYSTEMS 1. Introduction When a property is in multiple occupation, the risk of fire breaking out is greater than in an ordinary single family home. Some

More information

ENVIRONMENTAL HEALTH & SAFETY 6 East Dr., Amherst MA 01002-5000

ENVIRONMENTAL HEALTH & SAFETY 6 East Dr., Amherst MA 01002-5000 AMHERST COLLEGE ENVIRONMENTAL HEALTH & SAFETY 6 East Dr., Amherst MA 01002-5000 Michael Zlogar April 11, 2001 Assistant Fire Chief Amherst Fire Department 68 North Pleasant St. Amherst, MA 01004 FIRE ALARM

More information

Attachment 9. Trouble signals. Interfaced equipment. Primary (main) power supply

Attachment 9. Trouble signals. Interfaced equipment. Primary (main) power supply FIRE DETECTION, ALARM AND MASS NOTIFICATION SYSTEMS Inspection, testing, and maintenance of fire detection, alarm and Mass Notification systems shall be performed in accordance with the manufacturer's

More information

FIRE ALARM AND EMERGENCY COMMUNICATION SYSTEM RECORD OF COMPLETION

FIRE ALARM AND EMERGENCY COMMUNICATION SYSTEM RECORD OF COMPLETION FIRE ALARM AND EMERGENCY COMMUNICATION SYSTEM RECORD OF COMPLETION To be completed by the system installation contractor at the time of system acceptance and approval. It shall be permitted to modify this

More information

SMOKE DETECTOR INSTALLATION PROGRAM The Burlington Ordinance Perspective

SMOKE DETECTOR INSTALLATION PROGRAM The Burlington Ordinance Perspective SMOKE DETECTOR INSTALLATION PROGRAM The Burlington Ordinance Perspective The National Fire Alarm Code, NFPA 72, sets the minimum requirements of performance, selection, use and location of automatic detection

More information

AVAILABLE TO DOWNLOAD ON THE APOLLO APP. Pocket guide to. Fire Alarm Systems Design BS 5839-1. Standard

AVAILABLE TO DOWNLOAD ON THE APOLLO APP. Pocket guide to. Fire Alarm Systems Design BS 5839-1. Standard Pocket guide to Fire Alarm Systems Design BS 5839-1 Standard AVAILABLE TO DOWNLOAD ON THE APOLLO APP The Regulatory Reform (Fire Safety) Order (FSO) became law on 1 October 2006 Legally you must comply!

More information

Pollution CO CO 2. Carbonaceo us soot H 2 S, NOX, SO2

Pollution CO CO 2. Carbonaceo us soot H 2 S, NOX, SO2 Pollution CO CO 2 Carbonaceo us soot H 2 S, NOX, SO2 The National Building Code (NBC) contains set of minimum provisions, designed to protect the safety of the public with regard to structural sufficiency,

More information

SECTION 16721 FIRE ALARM AND DETECTION SYSTEM

SECTION 16721 FIRE ALARM AND DETECTION SYSTEM SECTION 16721 FIRE ALARM AND DETECTION SYSTEM PART 1 - GENERAL 1.1 RELATED DOCUMENTS: A. Drawings and general provisions of Contract, including General and Supplementary Conditions and Division-1 Specification

More information

Ontario s 2012 Building Code Division B, Part 9 (Ontario Regulation 332/12)

Ontario s 2012 Building Code Division B, Part 9 (Ontario Regulation 332/12) Ontario s 2012 Building Code Division B, Part 9 (Ontario Regulation 332/12) Notice: This e-learning module is intended for general information purposes only. It only highlights certain provisions of the

More information

1. The objective of this guideline is to provide minimum standards for design and installation of fire alarm systems for the University of Missouri.

1. The objective of this guideline is to provide minimum standards for design and installation of fire alarm systems for the University of Missouri. GENERAL: 1. The objective of this guideline is to provide minimum standards for design and installation of fire alarm systems for the University of Missouri. 2. Fire alarm systems are Life Safety Systems

More information

Fire Alarm system Installation Guide

Fire Alarm system Installation Guide Fire Alarm system Installation Guide Fire Alarm System Categories Systems designed for Protection of Property only, fall into two classifications P1 or P2. but a manual system is also needed, then this

More information

Design Options (Tradeoffs) Allowed by the 2012 Building Codes for Properties with Sprinkler Systems. April 2013

Design Options (Tradeoffs) Allowed by the 2012 Building Codes for Properties with Sprinkler Systems. April 2013 Design Options (Tradeoffs) Allowed by the 2012 Building Codes for Properties with Sprinkler Systems April 2013 The National Multi Housing Council and the National Apartment Association (NMHC/NAA) have

More information

NC State University Design and Construction Guidelines Division 26 Fire Alarm Systems

NC State University Design and Construction Guidelines Division 26 Fire Alarm Systems NC State University Design and Construction Guidelines Division 26 Fire Alarm Systems 1.0 Purpose A. The following guideline provides the minimum standards and requirements for fire alarm systems. 2.0

More information

Reference numbers following checklist statements represent an NFPA code section unless otherwise specified.

Reference numbers following checklist statements represent an NFPA code section unless otherwise specified. Fire Alarm System Plan Review Checklist 2010 OFC and 2007 NFPA 72 This checklist is for jurisdictions that permit the use of the 2007 NFPA 72 in lieu of IFC s referenced 2002 NFPA 72. Date of Review: Permit

More information

FIRE AND LIFE SAFETY REQUIREMENTS FOR CONVENTIONS, TRADE SHOWS AND EXHIBITS

FIRE AND LIFE SAFETY REQUIREMENTS FOR CONVENTIONS, TRADE SHOWS AND EXHIBITS FIRE AND LIFE SAFETY REQUIREMENTS FOR CONVENTIONS, TRADE SHOWS AND EXHIBITS November 2011, Updated March 2012 COLORADO SPRINGS FIRE DEPARTMENT Division of the Fire Marshal If you have any questions or

More information

New Ontario Building Code Requirements for Mid-rise Wood Frame Buildings

New Ontario Building Code Requirements for Mid-rise Wood Frame Buildings New Ontario Building Code Requirements for Mid-rise Wood Frame Buildings Note: This information addresses complex issues in a summary fashion. Consideration should be given to the official version of the

More information

FIRE ALARM SYSTEMS PERMIT APPLICATION, PLAN SUBMITTAL, DESIGN, INSTALLATION AND INSPECTION REQUIREMENTS Effective Date: January, 2011

FIRE ALARM SYSTEMS PERMIT APPLICATION, PLAN SUBMITTAL, DESIGN, INSTALLATION AND INSPECTION REQUIREMENTS Effective Date: January, 2011 Office of the Fire Marshal 1.0 PERMITS FIRE ALARM SYSTEMS PERMIT APPLICATION, PLAN SUBMITTAL, DESIGN, INSTALLATION AND INSPECTION REQUIREMENTS Effective Date: January, 2011 1.1 To acquire an installation

More information

Security Systems Intrusion Alarm

Security Systems Intrusion Alarm Dufferin-Peel Catholic District School Board STANDARD TEXT GUIDELINE FOR Security Systems for SECONDARY AND ELEMENTARY SCHOOLS Prepared by the Plant Department With Assistance from Vision Dynamics Formatted

More information

FIRST ALERT INSTRUCTION MANUAL FOR FA 270 KEYPADS SECURITY SYSTEM

FIRST ALERT INSTRUCTION MANUAL FOR FA 270 KEYPADS SECURITY SYSTEM FIRST ALERT INSTRUCTION MANUAL FOR FA 270 KEYPADS SECURITY SYSTEM Page 0 Table of Contents Introduction 1 System Basics.. 1 Burglary Protection.. 1 Fire Protection.. 1 Security Codes. 1 Zones and Partitions

More information

Fire Alarm Systems Requirements by Occupancy Type

Fire Alarm Systems Requirements by Occupancy Type WALT WHITE Fire Chief 5770 Freeport Blvd., Suite 200 Sacramento, CA 95822-3516 Ph: (916) 808-1300 Fax: (916) 808-1629 www.sacfire.org Fire Alarm Systems Requirements by Occupancy Type 2013 California Building

More information

GENERAL FIRE SAFETY TERMS & DEFINITIONS

GENERAL FIRE SAFETY TERMS & DEFINITIONS UCL Fire Technical Note - TN006 Fire Safety Technical Guide GENERAL FIRE SAFETY TERMS & DEFINITIONS Reference: BS4422-2005 Fire Safety Vocabulary - for further information and definitions BS EN ISO 13943-2000:

More information

Educational. Educational-Existing 1/28/2014. OCCUPANT LOADS [no change] Application. Application

Educational. Educational-Existing 1/28/2014. OCCUPANT LOADS [no change] Application. Application February 2014 Code Requirements and Inspections in Educational Occupancies Presented By: Barry W. Rickert Douglas M. Schanne Fire Marshal Training Program Supervisor Office of Education & Data Management

More information

SECTION 28 31 11 FIRE ALARM AND DETECTION SYSTEM

SECTION 28 31 11 FIRE ALARM AND DETECTION SYSTEM KNOXVILLE, TENNESSEE SECTION 28 31 11 PAGE 1 PART 1 - GENERAL 1.01 DESCRIPTION OF WORK SECTION 28 31 11 A. Extent of fire alarm and detection system work shall be as described in this specification, as

More information

B. NICET: National Institute for Certification in Engineering Technologies.

B. NICET: National Institute for Certification in Engineering Technologies. PART 1 - GENERAL 1.01 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections, apply to this Section.

More information