Miami-Dade Qualified Drainable Blade Louvered Penthouse



Similar documents
EDD-401. Stationary Louver Dual Drainable Blade. Application and Design. Standard Construction

Metal Wall Panels. Colorweld 300 Architectural Finishes

AIR CONDITIONING PRODUCTS COMPANY

MIAMI-DADE COUNTY PERFORMANCE TEST REPORT. Report No.: B Rendered to: CAPTIVEAIRE, INC. Blue Bell, Pennsylvania

Recirculating Roof Fans Models ESRMD, ESRMDF and ERD

FINISHES DESIGNATIONS... 2 PAINTED FINISHES...3, 4 STANDARD HARDWARE FINISH OFFERINGS...5, 6

PERFORMANCE TEST REPORT. Rendered to: BAMCO INC. PRODUCT TYPE: ACM Wall Panel Systems

HVAC Control & Balancing Dampers Models VCD, MBD and RBD

SECTION PREFORMED METAL STANDING SEAM ROOFING PART 1 - GENERAL 1.1 DESCRIPTION OF WORK

RAM Industries 8600 Commerce Park Dr Houston, TX Tel: Fax:

ASTM E 1886 / ASTM E 1996 AND ASTM E 283, ASTM E 330, ASTM E 331 TEST REPORT. Rendered to: BEKAERT SPECIALTY FILMS, LLC

Weather The Storm, with Wind

Steel Panel Frame. Exterior Steel Sheeting. Optional Rigid Insulation. Optional Steel Insulation Liner

ARTS AND CRAFTS (open) 5412 (doors) H : 84" Tote Tray Storage. Damp Storage. Tote Tray Storage. Notebook Board Storage, Doors

SECTION STANDING SEAM METAL ROOFING

security products metric sizes Redefine your comfort zone.

UPBLAST & HOODED PROPELLER ROOF VENTILATORS

City of San Diego, CWP Guidelines

GUIDELINE SPECIFICATIONS

ROOF TOP MOUNTED Air Handler Specification

Roof Curbs, Extensions and Equipment Supports

REQUEST FOR QUOTE. Material $ Labor/Installation $ tax $ Total $ Material $ Labor/Installation $ tax $ Total $

STANDING SEAM METAL ROOFING PANELS

A. Work on this project shall consist of, but is not limited to, the following:

AMD-33 Air Measuring Station with VCD-33 Control Damper

ABSeam Panel Overview and Installation Instructions

TEST REPORT. Report No.: A Rendered to: BAMCO INC. Middlesex, New Jersey. PRODUCT TYPE: Wall Cladding System SERIES/MODEL: Dry Concept

Evolve LED Area Light

Solar Mounting System

Accents & Accessories

TEST REPORT. Rendered to: TFC A DIVISION OF CENTURION INDUSTRIES, INC. Garrett, Indiana

SECTION METAL ROOF & WALL PANELS

CB-100 CB-150 CS-100 SL-100 SL-150 SLZ-1000

SECTION 6. Glass Storefront Doors:

PRODUCT SPECIFICATIONS

OGi Architectural Metal Solutions

SECTION GUARDA SECURITY WINDOW SCREENS

family of products is really Reichhold s answer to the growing need to meet more stringent regulations and performance requirements.

Open Up Your Space, Add Light Series 2050 and Series 2050i Garden Windows

SECTION STANDING SEAM METAL ROOF

Air-Conditioning, Heating, and Refrigeration Institute. Sheet Metal and Air-Conditioning Contractors National Association

VALOR STEEL BUILDINGS STANDARD SPECIFICATIONS

INSTRUCTIONS FOR HOW TO PROPERLY SELECT A FAN OR BLOWER

Drexel Metals Inc. DMC 100SS 16oz min. Copper Mechanical Seam Metal Roof System over Plywood

INDUSTRIAL ROOFING CASE STUDY: The Advantages of Aluminized Stainless Steel. Roof Installed:

Your Northeast Houston Full Service Screen Company

PERFORMANCE TEST REPORT. Rendered to: UNITED STATES ALUMINUM CORPORATION. SERIES/MODEL: 450 Center Glaze PRODUCT TYPE: Aluminum Curtain Wall

INNOVATIVE. ADAPTABLE. ENERGY EFFICIENT.

PRE-ASSEMBLED INSTALLATION INSTRUCTIONS FOR PACB SERIES COAL FIRED OVENS

Impact-Resistant Windows and Sliding Glass Doors

PERFORMANCE TEST REPORT. Rendered to: TREMCO INCORPORATED. SERIES/MODEL: Proglaze ETA PRODUCT TYPE: Engineered Transition Assembly

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM

Table of Contents PART 1 WINDOW SELECTION GUIDE. Window and Door Selection Guide

PERFORMANCE TEST REPORT. Rendered to: ARCHITECTURAL METAL SOLUTIONS, INC.

METALSOURCE. Awning Profiles

Drum Dispensing Stations

The Peak of Protection

n Three 4 x 4 butt hinges per door - prevents wracking and assures smooth positive operation n Heavy duty 16 gauge steel frame

JANUARY, 2016 TR-7100 Windows (Fixed) 1 EC ALUMINUM WINDOWS Guide Specs

COLORADO MODEL. 35 x 65 SPECIFICATIONS

INSTALLATION MANUAL For Grand Rib-3 / Multi Purpose / & Classic Rib Roofing Panels

SECTION ALUMINUM FRAMED ENTRANCES and STOREFRONTS. System 402 Flush-Glazed Screw Spline Storefront

FM 4473 TEST REPORT. Rendered to: VTECH INDUSTRIES, LLP. SERIES/MODEL: 4 x 4 CMC Hurricane PRODUCT TYPE: Skylight

A. Double lock standing seam, single element, metal roof panels.

Tube Axial Roof Upblast Model TAUB with Fabricated Steel Propeller

SECTION SECTIONAL OVERHEAD DOORS 521 SERIES ALUMINUM SECTIONAL OVERHEAD DOORS

Peel & Seal Self-Stick Roofing Solutions

SECTION ALUMINUM HANDRAIL AND RAILING SYSTEMS WITH DECORATIVE METAL PANEL INFILLS

Johnson Air-Rotation Systems

AAMA/WDMA/CSA 101/I.S.2/A TEST REPORT. Rendered to: EAGLE WINDOW & DOOR COMPANY

Anodizing Reference Guide

Ventilation Solutions Kitchens. fantech

MIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER)

A. Air-Conditioning and Refrigeration Institute: 1. ARI Commercial and Industrial Air Filter Equipment.

ROOFING APPLICATION STANDARD (RAS) No. 150 PRESCRIPTIVE BUR REQUIREMENTS

Sapa: SECTION ARCHITECTURAL ALUMINUM HANDRAILS AND RAILINGS

AMCA Publication (Rev )

Life Safety Dampers Selection and Application Manual. Ceiling Radiation Dampers Fire Dampers Combination Fire Smoke Dampers Smoke Dampers

ASTM E 1886 and ASTM E 1996 TEST REPORT. Rendered to: NORSE, INC.

Metal Roofing Practical Design

SECTION COILING COUNTER DOORS. Display hidden notes to specifier. (Don't know how? Click Here)

How To Test For An Architectural Test

Light Gauge Panels. Metal Sales Manufacturing Corporation

Wind Mitigation Inspection

AMD-23-TD. Thermal Dispersion Air Measuring Station with VCD-23 Control Damper. Application and Design. Ratings. Features and Control Options.

Storage Store the siding in a dry and ventilated area. Do not place it directly on the ground. Always cover the siding after a day s work.

Asphalt Shingle Application Requirements

TIGER Drylac U.S.A., Inc Swenson Avenue St Charles, IL T F office.us@tiger-coatings.us

COMMERCIAL COOKING HOODS, VENTILATION & FIRE SUPPRESSION SYSTEM GUIDELINES AND PROCEDURES

BURNISHED SLATE COVER PHOTO: SLATE GREY

SECTION AIR CONDITIONING UNIT

Window Installation Instructions

Modular Make-Up Air Unit

AAMA Voluntary Specification, Performance Requirements and Test Procedures for Superior Performing Organic Coatings on Aluminum Extrusions

Phoenix-3W Series One-Way Security Revolving Doors

Assessing Curtain Walls

Evolve LED Area Light

GCS

ASME Packaged Indirect Fired Water Heater

Transcription:

Application and Design is a gravity intake or exhaust louvered penthouse. Model incorporates high performance horizontal drainable style blades. Meets the performance requirements established by the Florida Building Code and Miami-Dade County. Tested in accordance with and passes TAS 201 (Large Missile Impact), TAS 202 (Uniform Static Air Pressure) and TAS 203 (Cyclic Wind-Loading). This system should be installed in a location where the enclosed area/room inside the penthouse is designed to drain water penetrating into the area/room, and the area/room will house water resistant/proof equipment, components and/or supplies. Roof curbs specifically designed for model may be supplied by Greenheck as an option. Qualified for installation onto concrete/masonry, steel stud, structural steel or wood substrate. Model may also be supplied as an equipment enclosure without hood members. Standard Construction Frame.........Heavy gauge extruded 6063-T5 aluminum, 6 in. x 0.081 in. nominal wall thickness Blades.........Drainable blade design, heavy gauge extruded 6063-T5 aluminum, 0.081 in. nominal wall thickness, positioned at 37º angles on approximately 4 in. centers Construction....Welded and mechanically fastened Birdscreen......3/4 in. x 0.051 flattened expanded aluminum removable frame, inside mount (rear) Finish..........Mill Minimum Throat Size.....12 in. W x 12 in. L Maximum Throat Size.....84 in. W x 108 in. L Minimum Louver Height...12 in. Maximum Louver Height...84 in. Options (at additional cost) A variety of bird and insect screens Blank-off panels Filter racks Hood Hood insulation Roof curb-flat or pitched Security bars A variety of architectural finishes including: Clear anodize Integral color anodize Baked enamel Kynar Miami-Dade Qualified Drainable Blade Louvered Penthouse Florida Product Approval No: FL11350.2

PERFORMANCE DATA Performance data shown herein is a result of in-house airflow resistance testing procedures in an AMCA Accredited Laboratory. The static pressure drops shown at given throat velocities include the pressure drop through the throat of the product as well as through the louvers themselves. The recommended height shown herein allows for equal to or greater than effective louver free area to that of the penthouse inside throat area. Increasing the product height will have minimal affect on the static pressure drop. The static pressure drops shown do not include the effects of bird screen, insect screen or any other appurtenance. Throat W x L Recommended Louver Height Louver Throat Area (sq. ft.) Intake CFM Exhaust CFM Total Pressure Drop in inches wg* Total Pressure Drop in inches wg* 0.067 0.152 0.268 0.030 0.068 0.120 0.187 Throat Velocity (ft./min.) Throat Velocity (ft./min.) 400 600 800 400 600 800 1000 12 x 12 12 1 400 600 800 400 600 800 1000 12 x 24 16 2 800 1200 1600 800 1200 1600 2000 24 x 24 16 4 1600 2400 3200 1600 2400 3200 4000 24 x 48 20 8 3200 4800 6400 3200 4800 6400 8000 36 x 36 20 9 3600 5400 6400 3600 5400 6400 9000 36 x 72 24 18 7200 10,800 14,400 7200 10,800 14,400 18,000 48 x 48 24 16 6400 9600 12,800 6400 9600 12,800 16,000 48 x 96 32 32 14,400 21,600 28,800 14,400 21,600 28,800 36,000 60 x 60 28 25 10,000 15,000 20,000 10,000 15,000 20,000 25,000 60 x 108 36 45 18,000 27,000 36,000 18,000 27,000 36,000 45,000 72 x 72 32 36 14,400 21,600 28,800 14,400 21,600 28,800 36,000 72 x 96 40 48 19,200 28,800 38,400 19,200 28,800 38,400 48,000 84 x 84 40 49 19,600 29,400 39,200 19,600 29,400 39,200 49,000 84 x 96 40 56 22,400 33,600 44,800 22,400 33,600 44,800 56,000 84 x 108 44 63 25,200 37,800 50,400 25,200 37,800 50,400 63,000

DETAILS

DETAILS SINGLE SECTION-WITHOUT HOOD

DETAILS TWO SECTION-WITHOUT HOOD

DETAILS LESS THAN 54 IN. HEIGHT

DETAILS GREATER THAN 54 IN. HEIGHT

CURB DETAILS

ROOF OPENING DETAILS

OPTION DRAWINGS Miami-Dade NOA No.:13-0510.05, EXP. 6/19/18 FINISHES Finish Type Description/Application Color Selection Standard Warranty (Aluminum) 2-coat 70% KYNAR 500 /HYLAR 5000 AAMA 2605 Dry film thickness 1.2 mil. (AKA: Duranar, Fluoropon, Trinar, Flouropolymer, Polyvinylidene Fluoride, PVDF2) Best. The premier finish for extruded aluminum. Tough, long-lasting coating has superior color retention and abrasive properties. Resists chalking, fading, chemical abrasion and weathering. Standard Colors: Any of the 24 standard colors shown can be furnished in 70% or 50% KYNAR 500 /HYLAR 5000 or Baked Enamel. 10 Years (Consult Greenheck for availability of extended warranty) 2-coat 50% KYNAR 500 /HYLAR 5000 AAMA 2604 Dry film thickness 1.2 mil. (AKA: Acroflur, Acrynar ) Baked Enamel AAMA 2603 Dry film thickness 0.8 mil. (AKA: Acrabond Plus, Duracron ) Better. Tough, long-lasting coating has excellent color retention and abrasive properties. Resists chalking, fading, chemical abrasion and weathering. Good. Provides good adhesion and resistance to weathering, corrosion and chemical stain. 2-Coat Mica: Greenheck offers 9 standard 2-coat Mica colors. Other colors are available. Consult Greenheck for possible extra cost when selecting non-standard colors or special finishes. 5 Years 1 Year Integral Color Anodize AA-M10C22A42 (>0.7 mil) Clear Anodize 215 R-1 AA-M10C22A41 (>0.7 mil) Clear Anodize 204 R-1 AA-M10C22A31 (0.4-0.7 mil) Industrial coatings Mill Two-step anodizing is produced by following the normal anodizing step with a second, colorfast process. Clear, colorless and hard oxide aluminum coating that resists weathering and chemical attack. Clear, colorless and hard oxide aluminum coating that resists weathering and chemical attack. Light, Medium or Dark Bronze; Champagne; Black Clear Clear Greenheck offers a number of industrial coatings such as Hi-Pro Polyester, Epoxy, and Permatector. Consult a Greenheck Product Specialist for complete color and application information. Materials may be supplied in natural aluminum or galvanized steel finish when normal weathering is acceptable and there is no concern for color or color change. 5 years 5 years 1 Year Consult Greenheck Finishes meet or exceed AAMA 2605, AAMA 2604, and AAMA 2603 requirements. Please consult www.greenheck.com for complete information on standard and extended paint warranties. Paint finish warranties are not applicable to steel products. Weather Infiltration Disclosure Louvered penthouses provide a level of defense against weather infiltration, however; louvered penthouses cannot be considered weather proof. Greenheck recommends provisions to manage weather infiltration be present beyond the louvered penthouse so as to mitigate weather passage and prevent water related damage to building conditions or equipment. Design of or materials as required to manage weather infiltration are not provided by Greenheck. Greenheck also recommends sound product application/engineering practice(s) be employed when applying louvered penthouses. Such practice(s) may include, but are not limited to, conservative throat and louver free area velocities. Greenheck shall not be held liable for water related damage to building conditions or equipment n/a September 2009 Rev. 4 Copyright 2009 Greenheck Fan Corporation Greenheck Fan Corporation reserves the right to make product changes without notice.