Modular Make-Up Air Unit
|
|
|
- Alfred Stevenson
- 9 years ago
- Views:
Transcription
1 Modular Make-Up Air Unit Model MSX Configurable Design ,000 cfm 4 in. wg External Static Pressure Hot Water, Electric or Steam Heating Packaged DX (3 to 16 tons), Split DX Cooling, Chilled Water or Evaporative Cooling Forward-Curved or Direct Drive Backward-Curved Plenum Supply Fan Options September 2015
2 Product Overview Model MSX Modular Supply Unit The Greenheck model MSX is an ideal make-up air unit where gas-fired heating is not desired or available. Coil heating and/or cooling tempering options are available with airflow volumes up to 48,000 cfm. The MSX may also be used for untempered applications. A flexible design concept enables each product to be customized for its application. Units are factory-assembled and wired to minimize field installation labor. The result is a semi-custom product at an attractive cost. Heating Options Hot water, steam and electric heat options are available. The heating section consists of a factory-installed heating coil in a pre-engineered housing. Water and steam coil connections are stubbed through the wall for installation convenience. The heating coil section is installed upstream of the fan section for a draw-thru arrangement and provides a streamlined transition to adjacent sections. For proper coil sizing, use Greenheck s CAPS selection software or contact your local representative. Hot Water and Steam Hot water and steam distributing coils are available in either a 100% thru-coil airflow or face and bypass arrangement. Coils have copper tubes with permanently expanded aluminum fins and are tested and rated in accordance with AHRI 410. Available with airflow capacities up to 40,000 cfm. Cooling Coils MSX model shall be ETL Listed to UL1995 MSX shown with optional filter section, hot water coil, forward-curved supply fan and end discharge. Electric Heat Electric heaters are UL Listed and feature open coil heating elements. Heater control cabinets are installed completely within the heating section and are factory wired up to 218 kw. All units with electric heat include a single-point power connection. Both chilled water and direct expansion coils for split systems are available. The cooling section includes the cooling coil, double-pitched stainless steel drain pan sloped in opposite directions for positive draining, and insulated double-wall construction. Drain and coil connections are stubbed through the wall for convenience. Chilled Water Coils: Available from two to six rows and numerous circuiting configurations to meet various load conditions. Airflow ranges up to 11,700 cfm in both water and glycol applications. Coil performance shall be calculated in accordance with AHRI 410. Direct Expansion (DX) Coils: DX coils for use in split systems are available from two to six rows. Circuiting options include single, face-split, and interlaced arrangements. 2 All heating and cooling coils can be coated with an ElectroFin coil coating upon request!
3 Tempering Options Packaged Direct Expansion (PDX) Providing unconditioned make-up air through ceiling diffusers or perforated kitchen hood plenums can create an uncomfortable work environment during summer months in commercial kitchens. Although conditioned make-up air can increase comfort levels, the need to cool and dehumidify this air to a 55 F supply air temperature can be detrimental to the food preparation process, significantly increase equipment first cost, and annual energy cost. The packaged DX cooling option is designed to cool the kitchen make-up air to a F supply air condition to improve space comfort and enhance employee productivity at an economical first cost while keeping energy costs low. Airflow Arrangement - Optional variable air volume or 100% outdoor air constant volume Performance Range - 1,000 to 7,500 cfm Cooling Capacity - 3 to 16 nominal cooling tons All units selected with the PDX option include: Efficient, direct drive condenser fans that are statically and dynamically balanced. Condenser and evaporator coils with copper tubes mechanically expanded in aluminum fins. Evaporator coils are mounted on a stainless steel drain pan. Thermal expansion valves provide refrigerant control. Quiet-running, hermetic scroll-type compressors mounted in an isolated compartment to be serviceable without affecting airflow. Mounted on neoprene isolators to minimize vibration transmission and noise. Features Draw-thru cooling arrangement Standard high and low pressure cutouts and crank case heaters Low discharge temperature cutout Benefits Even airflow across coils for efficient cooling operation and less chance of water carryover Increased compressor life Prevents coils from freezing Evaporative Cooling The evaporative cooling section includes a galvanized steel housing with a louvered intake, 2-inch aluminum mesh filters and a stainless steel evaporative cooling frame around the media. The evaporative cooling media is Munters CELdek or GLASdek and has a depth of 12 inches for 90% cooling effectiveness. The entire section mounts directly to the front of the unit, eliminating transition or ductwork by others. Drain and overflow are conveniently tapped through the side of the cooling section. The supply line connection is field located where convenient. Airflow capacity for evaporative cooling is up to 48,000 cfm. The evaporative cooling section for units above 9,000 cfm ships separately. Control Options: Recirculating Pump: Includes a pump that recirculates water over the evaporative media and is activated by a call for cooling. A field-adjustable bleed-off valve keeps mineral concentrations low. Auto Drain and Flush: Includes a recirculating pump and a field-adjustable timer that will periodically flush the sump to minimize mineral build-up. 3
4 MSX Standard and Optional Features 1 S Standard Feature O Optional Feature Construction Constructed of heavy-gauge G90 galvanized steel Single or double-wall construction with 1-inch fiberglass insulation Removable access panels with optional hinged doors Available finishes include: - Permatector (1,800 hr/salt spray rating under ASTM B117 testing conditions) - Hi-Pro Polyester (4,000 hr/salt spray rating under ASTM B117 testing conditions) - Baked Enamel coatings available in 16 standard colors or custom color match 5 1 Heating Options Hot water coils Standard steam coils Steam distributing coils for improved freeze resistance Face and bypass steam or hot water coils Electric heater up to 218 kw with a single-point power connection 2 Weatherhood Weatherhood with birdscreen features a wire mesh intake, preventing large debris from damaging the filters. An additional filter section is required. Aluminum mesh filtered weatherhood eliminates the need for an additional filter section Louvered weatherhood includes a drainable blade louver at intake with 2-inch aluminum mesh filters Dampers Low-leakage non-insulated inlet damper with factory-mounted and wired actuators Low-leakage insulated or non-insulated outlet damper 4 Filter Section V-bank filter section or mixing box 2-inch washable aluminum mesh 2-inch MERV 8 pleated disposable 2-inch MERV 13 pleated disposable 4-inch MERV 14 pleated disposable 2-inch MERV 8 and 2-inch MERV 13 pleated disposable 2-inch MERV 8 and 4-inch MERV 14 pleated disposable 6 Cooling Options All cooling options include a stainless steel drain pan Evaporative cooler Chilled water coils Split DX coil (coils only) Packaged direct expansion (PDX) Includes condensing fans and coils. Only available on forward-curved fan models. 4
5 Control Center 24 volt control voltage Magnetic motor starter with solid state overload protection Control transformer Disconnect switch Distribution terminal strip UL Listed, Recognized, or Classified electrical components Factory prewired for single-point power connection Supply Fan Options Forward-curved fan with optional factoryprovided VFD Direct drive backward-curved plenum fan with factory-provided VFD (shown) Balanced wheels to ensure a vibration-free operation Vibration Isolators The entire fan and motor assembly is mounted on vibration isolators to minimize noise transmission into the building. Neoprene or spring isolators are available on forward-curved supply fan models. Backward-curved supply fan models only offer neoprene isolators. Optional Electrical Controls Auxiliary Contacts Normally open and normally closed contacts are available for supply fan status and supply fan interlocks. Coil Freeze Protection Adjustable temperature sensing capillary tube which will disable the fan motor at 35ºF. This freeze protection is NOT a substitute for draining of water-filled coils. Cooling Relay When interlocked with a rooftop unit (RTU), this relay can be used to lockout a call for heat from the make-up air unit when there is a simultaneous call for cooling from the RTU. Dirty Filter Sensor Monitors the pressure drop across the filter section. If the pressure drop is higher than the field-adjustable setting, the switch will trip and indicate that the filters need to be cleaned or replaced. An indicator light may be wall/beam mounted or provided with a remote panel. Exhaust Fan Starter(s) Factory-mounted and wired for an electrical interlock between the supply and exhaust fan(s). Fire Stat Type III Shipped loose for field mounting and wiring in the supply or return air duct. Contains two normally open and two normally closed contacts for alarm notification. Freeze Protection Automatically shuts down the supply fan when the discharge temperature is below the set point for an extended amount of time. This prevents the unit from discharging non-tempered air into the building and freezing pipes and other temperature sensitive items. Heating Inlet Air Sensor Automatically turns the heat on and off based on a field-adjustable set point. Inlet Damper End Switch Will not allow starter to engage until end switch is proved, ensuring that the inlet damper is fully open before unit operation. Service Receptacle A 115 volt GFCI outlet can be shipped loose or mounted externally in a NEMA 3R box for the convenience of service personnel. A separate 115 volt power source is required. Smoke Detector Shipped loose for field mounting and wiring in the supply or return air duct. Contains two normally open and two normally closed contacts for alarm notification. 5
6 Unit Options and Controls Mixing Box The mixing box option expands the make-up air application capabilities of the unit. This section includes low leakage control dampers for outdoor and return air and an actuator in a face and bypass configuration. Either 2-inch pleated disposable or 2-inch aluminum mesh filters are available within the mixing box section. Double wall construction is available. Weatherhoods with a mixing box include a louvered intake with 2-inch aluminum mesh filters to prevent moisture from entering the mixing box section. Control Options: Building Pressure Control: Outdoor air and return air dampers modulate to maintain desired building pressure. Furnace control is based on discharge temperature. A remote control panel with photohelic gauge is required with this option. Potentiometer Control: Enables manual control of the outdoor air and return air damper positions. A remote control panel is required with this option. External Signal: Outdoor air and return air dampers modulate based on an external 2-10 VDC or 4-20 ma signal. Unit Controls Remote Panel - Greenheck offers three types of remote control panels featuring a variety of switches, thermostats, temperature selectors and indicator lights. Installation and field-wiring is easy by using a numbered terminal strip for point-to-point wiring between the make-up air unit and the remote panel. Industrial/Severe Duty: The industrial panel features a variety of switches and indicator lights mounted on a Permatector coated steel box in a NEMA-1 enclosure. The severe duty offers a variety of indicator lights and switches mounted in/on a stainless steel panel satisfying the following NEMA enclosure requirements: 3, 3R, 4, 4X, 12. Kitchen (KSCP): Features toggle switches for kitchen hood lights, fans and tempering. A stainless steel faceplate for flush wall mounting and a junction box is included. Network Interface Controller - An optimum solution for connecting a make-up air unit to a Building Management System (BMS). The network interface controller offers an easy-to-use, remote-mounted display. It easily integrates to BACnet IP, BACnet MSTP, LonWorks or Modbus. Two operating options are available: Monitor only: Allows the BMS to monitor the status and functions of the unit through a factory-installed controller. Control commands will be provided by terminal style signals from a remote panel or external to the unit. Monitor and Control: Allows the BMS to monitor the status and command the basic functions of the unit through a factory-installed controller. A remote panel is not available with this option. 6 Model Number Code The model number code is designed to completely identify the unit. The correct code letters must be specified to designate the configurations and size. *If no P is shown, then a forward-curved fan is provided. Model Parent MSX - P115 - H22 Optional Fan *P - Backward-Curved Plenum Housing Size Wheel Diameter (in.) 8-36 Fan Quantity 1
7 Intake and Discharge Options Weatherhoods Birdscreen Filter Section Aluminum Mesh Filtered Supply Fan Options Louvered V-Bank Mixing Box Forward-Curved Backward-Curved Discharge Options Top or Bottom Discharge Left or Right Discharge (only available on backwardcurved plenum option) End Discharge Kitchen Combination Packages The Greenheck combination package simplifies installation and reduces field labor costs for kitchen ventilation systems. The pre-engineered design ensures that the supply fan, exhaust fan, curb and combination extension components interface properly. Equally important, Greenheck combination packages are specifically designed to comply with NFPA 96. NFPA 96 states: Exhaust duct must terminate at least 24 inches above the roof deck Fan discharge must be at least 40 inches above the roof deck Air intake shall have a horizontal separation of 10 feet from the exhaust discharge Consult local codes and the authority having jurisdiction if there are questions concerning the use of this product. 7
8 Additional Make-Up Air Products Direct Gas - Economy Model DGK Indirect Gas - Economy Model IGK Direct Gas - Standard Model DG Indirect Gas - Standard Model IG Direct Gas - Configurable Model DGX Indirect Gas - Configurable Model IGX Direct Gas - Industrial Model TSU Direct Gas - Vertical Model VSU Our Commitment As a result of our commitment to continuous improvement, Greenheck reserves the right to change specifications without notice. Specific Greenheck product warranties are located on greenheck.com within the product area tabs and in the Library under Warranties. Greenheck P.O. Box 410 Schofield, WI Phone (715) greenheck.com Prepared to Support Green Building Efforts Copyright 2015 Greenheck Fan Corp. 00.TAP.1029 R IW
SECTION 23 81 03 - PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM
SECTION 23 81 03 - PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Packaged rooftop air conditioning unit (5 tons and smaller). 2. Roof curb. 1.2
SECTION 15750 PACKAGED ROOFTOP AIR CONDITIONING UNITS
SECTION 15750 PART 1 - GENERAL 1.01 DESCRIPTION A. Section includes requirements for roof mounted, self-contained units, with electric cooling, and electric or reverse refrigeration cycle (heat pump) heating
SECTION 23 00 01 HEATING, VENTILATION AND AIR CONDITIONING EQUIPMENT
SECTION 23 00 01 HEATING, VENTILATION AND AIR CONDITIONING EQUIPMENT PART 1 - GENERAL 1.1 DESCRIPTION A. The Work specified in this Section consists of designing, furnishing and installing factory-assembled
Element D Services Heating, Ventilating, and Air Conditioning
PART 1 - GENERAL 1.01 OVERVIEW A. This section supplements Design Guideline Element D3041 on air handling distribution with specific criteria for projects involving design of a Data Center spaces B. Refer
CE6500 Energy Recovery Ventilator
ADVANCED COMMERCIAL Energy Recovery Ventilator PRODUCT SPECIFICATIONS & TECHNICAL DATA Features NOMINAL CAPACITY 5500-7000 CFM CASING Double-wall cabinet White exterior paint, -gauge galvanized steel -gauge
Johnson Air-Rotation Systems
AR Series TM Johnson Air-Rotation Systems Solution TM D Series TM FF Series TM 80/20 PR Series TM Johnson Air-Rotation systems announces a major addition to its product line, completing its line of high
Bring the fresh in. Dedicated Outside Air Systems
Bring the fresh in. Dedicated Outside Air Systems The inside story on outside air. On average, we breathe in 3,400 gallons of air each day. Ambient indoor air pollution is a major problem, affecting health
SECTION 23 81 43 HEAT PUMPS
SECTION 23 81 43 HEAT PUMPS PART 1 GENERAL 1.1 SUMMARY A. Section Includes: 1. Packaged rooftop heat pumps. 1.2 REFERENCES A. American Society of Heating, Refrigerating and Air-Conditioning Engineers:
Mechanical Rooftop Custom Capabilities
Mechanical Rooftop Custom Capabilities Mechanical Construction Capabilities Price manufactures a wide range of custom gas heat and DX cooled units to meet your new construction and retrofit needs. In addition
Recirculating Roof Fans Models ESRMD, ESRMDF and ERD
Recirculating Roof Fans Models ESRMD, ESRMDF and ERD Four-Way Fan Exhaust Supply Mix Recirculate BUILDING VALUE IN AIR. October 2005 Recirculating Roof Fans Exhaust/Supply/Recirculation/Mix Model ESRMD
VertiCool Space Saver 2 to 15 tons Water-Cooled and Chilled Water
2 to 15 tons Water-Cooled and Chilled Water Unique Solutions for Challenging HVAC Projects Your Choice for Limited Space Applications Water-Cooled Chilled Water The VertiCool Space Saver allows installation
SECTION 15732 AIR CONDITIONING UNIT
SECTION 15732 AIR CONDITIONING UNIT PART 1 GENERAL 1.01 SUMMARY A. Section includes: 1. Packaged, split system air conditioning unit No. 1. 1.02 REFERENCES A. Air-Conditioning, Heating, and Refrigeration
SECTION 11 78 13 MORTUARY REFRIGERATORS
PART 1 - GENERAL 1.1 DESCRIPTION SECTION 11 78 13 MORTUARY REFRIGERATORS SPEC WRITER NOTE: Delete between //---// if not applicable to project. Also delete any other item or paragraph not applicable in
RPV - RP - RA air handling units
APPLICATIONS Heating, ventilation, cooling >> FACTORIES >> WAREHOUSES >> HALLS >> DISTRIBUTION CENTRES >> COMMERCIAL PREMISES >> PLACES OF WORSHIP RPV - RP - RA air handling units www.reznor.eu RPV - RP
48/50EJ,EK,EW,EY038, 044, 048 SINGLE-PACKAGE COOLING UNITS VARIABLE VOLUME CONSTANT VOLUME FACTORY-INSTALLED OPTIONAL HEAT
48/50E-4SB 48/50EJ,EK,EW,EY038, 044, 048 SINGLE-PACKAGE COOLING UNITS VARIABLE VOLUME CONSTANT VOLUME FACTORY-INSTALLED OPTIONAL HEAT GAS HEAT ELECTRIC HEAT PERFORMANCE DATA CERTIFIED DIMENSION PRINT CERTIFIED
SPACE COOLERS. P.O. Box 956 Paoli, PA 19301 (800) 523-7590 FAX (610) 251-0805 www.coilcompany.com. The leader in packaged Space Cooling.
SPACE COOLERS P.O. Box 956 Paoli, PA 19301 (800) 523-7590 FAX (610) 251-0805 www.coilcompany.com The leader in packaged Space Cooling. 2 Table of Contents Description Space Cooler from Coil Company. A
HIGH EFFICIENCY RTU. www.reznorhvac.com HIGH EFFICIENCY, PACKAGED SPACE CONDITIONING. DX System IEER> 13.2 Gas Heat Efficiency > 92% Capacities Tons
Capacities 10-25 Tons 100-400 MBH HIGH EFFICIENCY, PACKAGED SPACE CONDITIONING DX System IEER> 13.2 Gas Heat Efficiency > 92% HIGH EFFICIENCY RTU 30-120 kw 3,000-11,550 CFM Comfort Comfort is determined
Innovent LASER Packaged Fresh Air Conditioning Units
LASER Latent And Sensible Energy Reduction Latent And Sensible Energy Reduction For Outside Air Innovent LASER Packaged Fresh Air Conditioning Units Innovent LASER units provide both sensible and latent
MODEL IX -WAC/HP AIR CONDITIONERS & HEAT PUMPS FOR HIGHLY CORROSIVE & HAZARDOUS AREAS
1.5, 2, 2.5, 3, 3.5, 4, 5 & 6 Ton Industrial Grade Wall Mounted Air Conditioners & Heat Pumps Unit Application Bebco Model IX-WAC/HP Industrial Grade Air Conditioners & Heat Pumps are designed as a total
PRE-ASSEMBLED REMOTE REFRIGERATION SYSTEMS
NOR-LAKE, INCORPORATED 727 Second Street P.O. Box 248 Hudson, Wisconsin 54016 800-955-5253 715-386-2323 866-961-5253 Parts 800-388-5253 Service 715-386-4291 FAX www.norlake.com Split-Pak Pre-Assembled
MAC-120HE-01 Air-Cooled Chiller
MAC-120HE-01 Air-Cooled Chiller 10 Ton / 120,000 BTUH Air-Cooled Chiller 208/230-1-50/60 1 HVAC Guide Specifications Air-Cooled Liquid Chiller Nominal Size: 10 Tons Multiaqua Model Number: MAC-120HE-01
Low Profile Unit Cooler
Super-Flo Now available with EC Motors High Efficiency / High Reliability Low Profile Unit Cooler Publication No. 411.4 November, 2008 S A N I T A T I O N F O U N D A T I O N A L N A T I O N Air Defrost
A. Section includes air conditioning units, controls and control panels.
SECTION 23 81 23 - COMPUTER-ROOM AIR-CONDITIONERS PART 1 - GENERAL 1.1 SUMMARY A. Section includes air conditioning units, controls and control panels. 1.2 REFERENCES A. Air-Conditioning, Heating, and
SPECIFICATION DIVISION 23 SECTION DESCRIPTION DIVISION 23 HEATING, VENTILATING AND AIR CONDITIONING (HVAC) SECTION 238221 - BLOWER COIL UNITS
ARCHITECTURE, ENGINEERING AND CONSTRUCTION P00000000 0000 DOCUMENTS ARCHITECTURE & ENGINEERING 326 East Hoover, Mail Stop B Ann Arbor, MI 48109-1002 Phone: 734-764-3414 Fax: 734-936-3334 SPECIFICATION
WALL MOUNTED PACKAGE AIR CONDITIONER REPLACEMENT PARTS MANUAL W70A1 W70L1. Models: Contents. General Notes. Important. Description
REPLACEMENT PARTS MANUAL WALL MOUNTED PACKAGE AIR CONDITIONER Models: W0A W0L General Notes Contents Revised and/or additional pages may be issued from time to time. A complete and current manual consists
M SERIES REFRIGERANT COIL MODULE REFRIGERANT COILS for R-22, R-407C, R-410A
Bulletin 20-20.2 / July 2012 M SERIES REFRIGERANT COIL MODULE REFRIGERANT COILS for R-22, R-407C, R-410A ➀ ➁ ➂ Model Number Key M 2430 C L 1 - A - ➀ Unit Type M=Modular Nominal Capacity 2430=24000 to 30000
Glossary of Heating, Ventilation and Air Conditioning Terms
Glossary of Heating, Ventilation and Air Conditioning Terms Air Change: Unlike re-circulated air, this is the total air required to completely replace the air in a room or building. Air Conditioner: Equipment
ARMSTRONG AIR HEAT PUMPS www.armstrongair.com
INDEX ELECTRIC FURNACE MODULAR AIR SYSTEM EFC/EFV... 5-10 electric Heat Kits... 5-11 evaporator coils EC1P / EM1P UPFLOW / COUNTERFLOW APPLICATIONS and upflow / horizontal applications (CASED)... 5-6 5-7
catalog Single Package Vertical Air Conditioners and Heat Pumps
catalog Single Package Vertical Air Conditioners and Heat Pumps Catalog: SK145.00-EG1 (1008) TABLE OF CONTENTS Single Package Vertical Units Introduction...............................................................................
Commercial Gas Furnace Upflow
Commercial Gas Furnace Upflow Model G24-200 80% A.F.U.E. 200,000 Btuh Input Heating Cap. 7.5 or 10 Tons Nominal Add-On Cooling GUK FEATURES Certified by A.G.A./C.G.A. Laboratories. Heavy gauge painted
Direct Gas-Fired Indoor and Outdoor Heating and Make-Up Air Units
Direct Gas-Fired Indoor and Outdoor Heating and Make-Up Air Units horizontal configuration vertical configuration 7-150.3 MAY, 2015 Table of Contents Direct-fired make-up units are designed to provide
1.2 Refrigerant Equipment. General
Part 1 General 1.1 Summary.1 Unless otherwise indicated, follow the standards below when specifying heating, ventilation and air conditioning (HVAC) work. These standards are not intended to restrict or
Installation Manual CLIFC Fan & Coil Variable Speed
Installation Manual CLIFC Fan & Coil Variable Speed General Description GENERAL DESCRIPTION FANS EQUIPMENT Totally Factory assembled within the unit all piping, wiring, and required controls for operation
WALL MOUNTED PACKAGE HEAT PUMPS REPLACEMENT PARTS MANUAL WH483 WH602. Contents. General Notes. Important. Description
REPLACEMENT PARTS MANUAL WALL MOUNTED PACKAGE HEAT PUMPS Models: WH421 WH483 WH602 General Notes Contents Ø Ø Revised and/or additional pages may be issued from time to time. A complete and current manual
CoolTop. A unique water cooled air-conditioning unit for server room cooling from the top AC-TOPx-CW-240/60
CoolTop A unique water cooled air-conditioning unit for server room cooling from the top AC-TOPx-CW-240/60 Application CoolTop is a new, unique air conditioning unit especially designed for datacenters.
SECTION 23 05 12 GENERAL PROVISIONS FOR HVAC WORK
SECTION 23 05 12 GENERAL PROVISIONS FOR HVAC WORK 1 GENERAL 1.1 GENERAL REQUIREMENTS A. This Section is coordinated with and complementary to the General Conditions and Supplementary General Conditions
FOXAIR 60/50 ALL MODELS
FOXAIR 60/50 ALL MODELS OPERATION AND SERVICE MANUAL UNIT WEIGHT - ALL MODELS APPROX. 300 POUNDS FOXTRONICS, INC. 38 L x 28 W x 24 H Love Field-Dallas TX MADE IN THE USA 3448 West Mockingbird Lane Dallas,
CA SERIES. Available in sizes from 3/4 through 1-1/4 tons the CA Series offers a wide range of features such as:
CA SERIES T he CA Aquarius Series Console Units offer the answer to providing heating and cooling to areas where space and access is limited. Office buildings, hotel/motels, schools and assisted living
Direct Gas Fired [Make-Up Air / Displacement Ventilation / Space Heating] System
Section 15622 AA-Series (rev. 04/16/15) Direct Gas Fired [Make-Up Air / Displacement Ventilation / Space Heating] System Note: Optional items and/or items requiring a choice, are shown between brackets
ROOF TOP MOUNTED Air Handler Specification
ROOF TOP MOUNTED Air Handler Specification PART 1: GENERAL (Model RT) Mechanical Specification 1.01 WORK INCLUDED A. Provide complete air handling unit(s) suitable for outdoor installation. Contractor
ECOCIAT. Domestic hot water heat recovery unit
Heat recovery unit Domestic hot water High energy efficiency with R410A Compact and quiet Scroll compressors Brazed-plate heat exchangers Heating Heat recovery ENVIRONMENTALLY HFC R410A PROTECTION DE FRIENDLY
SECTION 16720 - FIRE AND SMOKE ALARM SYSTEM. City of San Diego, CWP Guidelines
PART 1 -- GENERAL 1.1 WORK OF THIS SECTION SECTION 16720 - City of San Diego, CWP Guidelines A. The WORK of this Section includes providing manual and automatic fire alarm and smoke detection systems meeting
University of Houston Master Construction Specifications Insert Project Name
SECTION 23 62 13 - AIR-COOLED SPLIT SYSTEM AIR CONDITIONING UNITS PART 1 - GENERAL 1.1 RELATED DOCUMENTS: A. The Conditions of the Contract and applicable requirements of Division 1, "General Requirements",
AFHX Guide Specifications
AFHX Guide Specifications Part 1: General 1.01 Work Included A. Provide a complete Air Cooled Packaged Chiller utilizing rotary screw compressors suitable for outdoor installation and be controlled by
hore PRODUCT CATALOGUE nd Offsh arine an ms for Ma & Refrig AUTONOMOUS AIR CONDITIONERS HV VAC &
hore nd Offsh arine an ms for Ma geration System & Refrig HV VAC & PRODUCT CATALOGUE AUTONOMOUS AIR CONDITIONERS O ! "# $ % & " ' (! ) * +,+( -../01..2 PRODUCT CATALOGUE 72-17 AUTONOMOUS AIR CONDITIONERS
Heating, Ventilation, Air Conditioning and Refrigeration (HVACR)
Heating, Ventilation, Air Conditioning and Refrigeration (HVACR) I. Demonstrate safety skills in typical HVACR work situations to NATE Core Installer Knowledge Areas for Technician Excellence for Safety
Models: WA182, WA242. Contents. Cabinet Components. Functional Components " Exploded View... 3 " Usage List... 4. Control Panel.
REPLACEMENT PARTS MANUAL WALL MOUNTED PACKAGE AIR CONDITIONER Models: WA182, WA242 General Notes! Revised and/or additional pages may be issued from time to time.! A complete and current manual consists
THE WALL-MOUNT ONE TON AIR CONDITIONER GREEN REFRIGERANT R-410A. 10,800 Btuh 9.00 EER Right Side Control Panel. Engineered Features
THE WALL-MOUNT ONE TON AIR CONDITIONER W2A,800 Btuh 9.00 EER Right Side Control Panel 60Hz GREEN REFRIGERANT R-A The Bard Wall-Mount One Ton Air Conditioner is a self contained energy efficient heating
Defining Quality. Building Comfort. Heating and Cooling Coils
Defining Quality. Building Comfort. Heating and Cooling Coils Heating and Cooling Coils Heating and Cooling Coils For over 20 years, AAON has supplied the coil needs of industrial and commercial HVAC customers.
Models: Contents. Cabinet Components. Functional Components " Exploded View... 3 " Usage List... 4. Control Panel. Blower Housing
REPLACEMENT PARTS MANUAL WALL MOUNTED PACKAGE HEAT PUMPS Models: WH301 WH361 General Notes! Revised and/or additional pages may be issued from time to time.! A complete and current manual consists of pages
HVAC Checklist - Long Form
HVAC Checklist - Long Form Page 1 of 14 Appendix B discusses HVAC system components in relation to indoor air quality. utside Air Intake Location pen during occupied hours? Unobstructed? Standing water,
Commercial Semi-Instantaneous Water Heaters
FEATURES HWI Models A. O. Smith s HWI models are available for operation with steam or boiler water as the energy source. They are factory assembled with components sized, piped and checked at the factory
Utility Distribution Systems
Utility Distribution Systems 6/2012 A0011037 1 WARRANTY This equipment is warranted to be free from defects in materials and workmanship, under normal use and service, for a period of 12 months from date
MULTIZONE APPLICATION OF SOLUTION UNITS
MULTIZONE APPLICATION OF SOLUTION UNITS APPLICATION GUIDE Supersedes: 102.20-AG12 (206) Form: 102.20-AG12 (307) GENERAL Multi-zone heating and air conditioning units offer design and application advantages
K-Series Rooftop Units 60 HZ ASHRAE 90.1 COMPLIANT
PRODUCT SPECIFICATIONS PACKAGED GAS ELECTRIC KG K-Series Rooftop Units 60 HZ Bulletin No. KGA-092-50 (3/206) ASHRAE 90. COMPLIANT 7.5 to 2.5 Tons Net Cooling Capacity 86,000 to 38,000 Btuh Gas Input Heat
HEATER, AIR CONDITIONING AND VENTILATION
55-1 GROUP 55 HEATER, AIR CONDITIONING AND VENTILATION CONTENTS GENERAL DESCRIPTION 55-2 HEATER AND AIR CONDITIONING SYSTEM 55-4 HEATER CONTROL 55-6 A/C-ECU 55-7 A/C COMPRESSOR 55-9 CONDENSER 55-9 DUCT
The prevailing force in the field. AIR CONDITIONING SOLUTIONS FOR THE PULP AND PAPER INDUSTRY
The prevailing force in the field. AIR CONDITIONING SOLUTIONS FOR THE PULP AND PAPER INDUSTRY About HDT Nordic HDT Global, in business for over 75 years, acquired Nordic Air in 2010. Nordic was founded
Chilled Water HVAC Systems
Chilled Water HVAC Systems By Ron Prager, Brinco Mechanical Services, Inc. Types of water based systems: There are three types of HVAC systems that utilize water as a heat transfer medium. The first system,
COMMISSIONING OF HVAC SYSTEMS
FORM CL-01 SYSTEMS / EQUIPMENT INCLUDED : SYSTEM STARTUP CHECKLIST I - PRE - STARTUP INSPECTION EQUIPMENT MOUNTING & SETTING CONTROL, INTERLOCK & POWER WIRING ALIGNMENT OF MOTORS & DRIVES PIPING, CONNECTIONS
CB29M Bulletin #490071 February 1996
ENGINEERING DT MTCHED REMOTE SYSTEMS 50hz S LOWER UNITS 50hz ELITE 10 MULTI POSITION LOWER UNITS 20 100 to 49 00 tuh (5.9 to 14.4 kw) Cooling Capacity 19 700 to 49 100 tuh (5.8 to 14.4 kw) Heat Pump Heating
Legacy Chiller Systems, Inc. www.legacychillers.com 877-988-5464
WATER-COOLED Process CHILLERS SCROLL R407C, PACKAGED, Tankless PZW1S Legacy Chiller Systems, Inc. www.legacychillers.com Example: P Z W 1 S E 5 P P = Packaged IE = Indoor Evaporator OC = Outdoor Condenser
"EC" Series Electric Humidifier
EC-1 Standard Water "EC" Series Electric The Electric from PURE Co. is loaded with features and options. All you need is tap water, electricity, and a sanitary drain. The humidifier does the rest. These
26 AND 27 SLEEVES. IDEAL for NEW CONSTRUCTION, RETROFITS and REMODELS.
T H R U - T H E - W A L L A I R C O N D I T I O N E R S 26 AND 27 SLEEVES. IDEAL for NEW CONSTRUCTION, RETROFITS and REMODELS. W A L L M A S T E R T H R U - T H E - W A L L A I R C O N D I T I O N E R
"ES" Series Electric Humidifier
ES-1 Standard Water "ES" Series Electric Humidifier The Electric Humidifier from PURE Humidifier Co. is loaded with features and options. All you need is tap water, electricity, and a sanitary drain the
26 3213.13 Diesel Engine Driven Generators Page 1 of 6
Last Update: December 8, 2014 A. Description of System Consultant s Handbook Page 1 of 6 1. Provide a diesel engine driven electric generating unit, factory assembled, tested and certified to operate at
Dehumidification Frequently Asked Questions
Dehumidification Basics Why do you want to keep indoor Rh between 30-60%? ASHRAE recommends keeping the relative humidity in a home between 30-60% to limit the effects of many unwanted conditions and harmful
Liebert Hiross HPW The High Performance Wallmount Cooling Solutions for Telecom Mobile Remote Access Nodes
Precision Cooling for Business-Critical Continuity Liebert Hiross HPW The High Performance Wallmount Cooling Solutions for Telecom Mobile Remote Access Nodes We re Emerson Network Power, backed by Emerson,
LAKE COUNTY ANIMAL SERVICES EXPANSION SECTION 15459
SECTION 15459 PART 1 - GENERAL 1.1 RELATED DOCUMENTS: A. Drawings and general provisions of Contract, including General and Supplementary Conditions and Division-1 Specification sections, apply to work
CHILLED WATER DATA ROOM UNITS
Critical Infrastructure for the World s Leading Data Centers CHILLED WATER DATA ROOM UNITS Downflow Net Sensible Cooling 79 220kW Upflow Net Sensible Cooling 66 206kW A Nortek Company DATA CENTER COOLING
COIL INPUT SCREENS. ITEM NUMBER: Always use a 1 through? In this field you might also use a dash and place quantity of coils here.
COIL INPUT SCREENS Example of a Water Coil Input Screen: (*please see the appendix for an example of an Evaporator, Steam or Condenser Coil input screen) PHYSICAL DATA ITEM NUMBER: Always use a 1 through?
NEBB STANDARDS SECTION-8 AIR SYSTEM TAB PROCEDURES
NEBB STANDARDS SECTION-8 AIR SYSTEM TAB PROCEDURES 8.1 INTRODUCTION Testing, adjusting, and balancing of HVAC systems can best be accomplished by following a series of systematic procedures. The NEBB TAB
Life Safety Dampers Selection and Application Manual. Ceiling Radiation Dampers Fire Dampers Combination Fire Smoke Dampers Smoke Dampers
Life Safety Dampers Selection and Application Manual Ceiling Radiation Dampers Fire Dampers Combination Fire Smoke Dampers Smoke Dampers May 2014 1 2 Table of Contents HOW TO USE THIS MANUAL DAMPER APPLICATION
Why is my air conditioner dripping on my customers?
De-Mystifying HVAC Why is my air conditioner dripping on my customers? By Ron Prager One of the most frequent emergency service requests is a call for an air conditioner leaking water into the store. These
Cooling/Heat Pump Convertible Air Handlers
Cooling/Heat Pump Convertible Air Handlers 2/4TEC3F18-60A1000A 1½ 5 Ton PUB. NO. 22-1774-01-0905 (EN) Features and Benefits 13.0 SEER Ships horizontal converts to vertical by standing unit on end. Six-way
DUCT SMOKE DETECTOR D4120
Purpose/Application National and local safety standards and codes recognize the ability of air duct systems to transfer smoke, toxic gases, and flame from area to area. Sometimes smoke can be of such quantity
HVAC Processes. Lecture 7
HVAC Processes Lecture 7 Targets of Lecture General understanding about HVAC systems: Typical HVAC processes Air handling units, fan coil units, exhaust fans Typical plumbing systems Transfer pumps, sump
APC APPLICATION NOTE #112
#112 Best Practices for Deploying the InfraStruXure InRow SC By David Roden Abstract The InfraStruXure InRow SC (ACSC100 and ACSC101) is a self-contained air conditioner for server rooms and wiring closets.
GCS16 GCS20 WARNING CAUTION
Service Literature Corp. 0110 L6 Revised 12 2004 GCS16/GCS20 SERIES UNITS GCS16 GCS20 2 to 5 Ton GCS16/20 series units in the 2 to 5 ton (7.0 to 17.0 kw) cooling size are packaged combination gas heat
General Safety Information. Document 474681 Packaged DX Module. As used in Greenheck models DGX IGX MSX
Document 474681 Packaged DX Module Installation, Operation and Maintenance Manual Please read and save these instructions for future reference. Read carefully before attempting to assemble, install, operate
marine/bespoke split applications
split applications marine/bespoke evaporators, condensers and split air conditioning systems suitable for a multitude of applications such as coastal, extreme high and low ambients, harsh dusty environments
ENGINEERING GUIDE. Water-Cooled Self-Contained Units C-Series, Vertical
ENGINEERING GUIDE Water-Cooled Self-Contained Units C-Series, Vertical TABLE OF CONTENTS Introduction...2 Product Overview...3 Nomenclature...4 General Data...5 Cooling Performance Data....6 Evaporator
WATER COOLED SELF CONTAINED MODEL LSWU/LSWD WITH IPU2 CONTROL 025-105
WATER COOLED SELF CONTAINED AIR CONDITIONING UNITS INSTALLATION, OPERATION AND MAINTENANCE Supersedes 145.05-NOM5 and 145.05-NOM6 Form 145.05-NOM7 (412) 035-22910-007 WATER COOLED SELF CONTAINED MODEL
SWIMMING POOL HEAT PUMP
SWIMMING POOL HEAT PUMP Installation & User Manual Model HP40B HP50B HP65B Hayward Pool Products Canada, Inc. T: 1-888-238-7665 www.haywardpool.ca CONTENT I. Application 4 II. Features 4 III. Technical
Gas Unit Heaters Duct Furnaces Horizontal - 60 HZ Form No. LF24-100-400 (10/2011) LF24 Standard
LF Standard Features Horizontal unit heaters are compact in design and easy to install. Steady State Efficiencies of up to 80.%. Ideal for economical commercial heating systems. Shipped completely assembled
Lesson 36 Selection Of Air Conditioning Systems
Lesson 36 Selection Of Air Conditioning Systems Version 1 ME, IIT Kharagpur 1 The specific objectives of this chapter are to: 1. Introduction to thermal distribution systems and their functions (Section
Operation and Installation Manual. Max Series
Operation and Installation Manual Max Series Models 95MAX 155MAX 155ECM 155MAXRX 200MAX 200MAXRX MAXTOP 195DCS 300DCS 200ERV 200ERVD New Auto Dehumidistat Function prevents unwanted use of the dehumidistat
ModPac II 1 to 5-Ton Vertical Wall Mount Air Conditioners Models AVPA12-20-24-30-36-42-48-60
ModPac II 1 to 5-Ton Vertical Wall Mount Air Conditioners Models AVPA12-20-24-30-36-42-48-60 General Description The Marvair ModPac II air conditioner is a vertical, wall mounted, cost effective air conditioner
ROOFTOP - HEAT PUMP UNIT. This document applies when installing into an air handler or as part of an air handling system.
ROOFTOP - HEAT PUMP UNIT Technical data Applies to Model YNRA R410A This document applies when installing into an air handler or as part of an air handling system. CONTENTS 1. General description... 2
Air-Cooled Condensers
Air-Cooled Condensers 20 to 120 Tons April 2001 Introduction Air-Cooled Condensers Built for Every Need Trane has the right condenser...if you are designing a new system or replacing an existing air-cooled
Single Package Vertical Air Conditioners. Vert-I-Pak
Single Package Vertical Air Conditioners Vert-I-Pak Installs easily in a closet for quiet operation and provides a more homelike appearance for your guests. THE EXPERTS IN ROOM AIR CONDITIONING A Better
Chilled Water Fan Coil Unit. Model:HFCA Size 03~14
Chilled Water Fan Coil Unit Model:HFCA Size 03~4 The Best Choice for Comfort =The Best Results Quiet Comfort Slope coil avoid air flow perpendicular impact Low noise permanent split capacitor motor Metal
Basics of HVAC Cleaning
Basics of HVAC Cleaning Seminar Outline Residential 1. Types of systems used and why 2. Types of air distribution systems 3. System components 4. Determining the need for cleaning (ACR2002) 5. Project
Split System Cooling Product Data
Split System Cooling Product XL16i 1½ 5 Tons PUB. NO. 22-1890-01 Features and Benefits Climatuff compressor Efficiency up to 16.0 SEER and 9.0 HSPF All aluminum Spine Fin coil WeatherGuard fasteners Quick-Sess
Medical Air Systems: Scroll
GENERAL The Chemetron skid mount scroll medical air system is designed to provide medical breathing air for hospital and medical institutions. This system meets NFPA 99 requirements for Level 1 breathing
ASTACEA4 Inspect complex/central air conditioning systems
Overview This Unit covers the competences required to inspect complex/central air conditioning systems as defined by the CIBSE TM 44 Figure 1.1: Summary of system types and their component parts. The air
A. Air-Conditioning and Refrigeration Institute: 1. ARI 850 - Commercial and Industrial Air Filter Equipment.
SECTION 23 40 00 - HVAC AIR CLEANING DEVICES PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Activated carbon filters. 2. Extended surface rigid air filter with synthetic media. 3. Disposable panel
PACKAGE AIR CONDITIONERS REPLACEMENT PARTS MANUAL
REPLACEMENT PARTS MANUAL PACKAGE AIR CONDITIONERS Models: P1142A3 P1148A1 P1148A1-B P1148A1-C P1060A1 P1060A1-B P1060A1-C P1148A1-A/H P1148A1-B/H P1148A1-C/H P1060A1-A/H P1060A1-B/H P106A1-C/H General
Offshore Substation. HVAC System. ETS-09 Rev. 2. technical standards. Dok. 44969-09 Sag 09/1437
technical standards Offshore Substation HVAC System ETS-09 Rev. 2 Dok. 44969-09 Sag 09/1437 Revision survey Document title HVAC System Document no. 44972-09 Target group Fabrications Contractors and Designer
M7RL Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. High Efficiency / Direct Vent Condensing Downflow Gas Furnace
TECHNICAL SPECIFICATIONS M7RL Series High Efficiency / Direct Vent Condensing Downflow Gas Furnace Induced Draft - 9%+ AFUE Input 4,000 thru 7,000 Btuh The high efficiency downflow gas furnace is especially
Oil and Coolant Circulating Heating System. Model - OCSM
Oil and Coolant Circulating Heating System Model - OCSM Installation & Operation Manual 216280-000 REV 2 Identifying Your System The HOTSTART heating system is designed to heat fluids for use in marine