Data Center Energy Use, Metrics and Rating Systems

Similar documents
Energy Efficient High-tech Buildings

DOE Data Center Energy Efficiency Program

How Does Your Data Center Measure Up? Energy Efficiency Metrics and Benchmarks for Data Center Infrastructure Systems

DC Pro Assessment Tools. November 14, 2010

Benchmarking results from Indian data centers

Data Center Leadership In the DOE Better Buildings Challenge

Case Study: Innovative Energy Efficiency Approaches in NOAA s Environmental Security Computing Center in Fairmont, West Virginia

Data Center Energy Efficiency. SC07 Birds of a Feather November, 2007 Bill Tschudi wftschudi@lbl.gov

Green Data Centre Design

Measuring Power in your Data Center: The Roadmap to your PUE and Carbon Footprint

Recommendations for Measuring and Reporting Overall Data Center Efficiency

Data Centers: How Does It Affect My Building s Energy Use and What Can I Do?

Recommendations for Measuring and Reporting Overall Data Center Efficiency

Smarter Data Centers. Integrated Data Center Service Management

Re Engineering to a "Green" Data Center, with Measurable ROI

Self-benchmarking Guide for Data Center Infrastructure: Metrics, Benchmarks, Actions Sponsored by:

Data Center Industry Leaders Reach Agreement on Guiding Principles for Energy Efficiency Metrics

Managing Power Usage with Energy Efficiency Metrics: The Available Me...

Understanding Power Usage Effectiveness (PUE) & Data Center Infrastructure Management (DCIM)

Managing Data Centre Heat Issues

Electrical Systems. <Presenter>

Guideline for Water and Energy Considerations During Federal Data Center Consolidations

Green Computing: Datacentres

General Recommendations for a Federal Data Center Energy Management Dashboard Display

Green Computing: Datacentres

Case Study: Opportunities to Improve Energy Efficiency in Three Federal Data Centers

THE GREEN GRID DATA CENTER POWER EFFICIENCY METRICS: PUE AND DCiE

Increasing Energ y Efficiency In Data Centers

GREEN GRID DATA CENTER POWER EFFICIENCY METRICS: PUE AND DCIE

DATA CENTER ASSESSMENT SERVICES

Specialty Environment Design Mission Critical Facilities

AbSTRACT INTRODUCTION background

Energy Efficiency in New and Existing Data Centers-Where the Opportunities May Lie

CIBSE ASHRAE Group. Data Centre Energy Efficiency: Who, What, Why, When, Where & How

EU Code of Conduct for Data Centre Efficiency

Power Usage Effectiveness (PUE) & Data Center Infrastructure Efficiency (DCiE) Progress

Control of Computer Room Air Handlers Using Wireless Sensors. Energy Efficient Data Center Demonstration Project

Energy Efficiency Opportunities in Federal High Performance Computing Data Centers

Reducing Data Center Loads for a Large-Scale, Net Zero Office Building

Identifying Energy Saving Opportunities in the Data Center

Defining Quality. Building Comfort. Precision. Air Conditioning

BCA-IDA Green Mark for Existing Data Centres Version EDC/1.0

World s Greenest High Performance Data Center

Datacenter Efficiency

AIA Provider: Colorado Green Building Guild Provider Number: Speaker: Geoff Overland

The Mission Critical Data Center Understand Complexity Improve Performance

GREEN DATA CENTER DESIGN

ERE: A METRIC FOR MEASURING THE BENEFIT OF REUSE ENERGY FROM A DATA CENTER

Data Center RD&D at EPRI

Increasing Data Center Efficiency through Metering and Monitoring Power Usage

ICT and the Green Data Centre

Data Centers That Deliver Better Results. Bring Your Building Together

Electrical Efficiency Modeling for Data Centers

A Market Transformation Programme for Improving Energy Efficiency in Data Centres

Agenda. Part I: Introduction to OptimumHVAC. Part II: Initial Energy Savings Analysis for MCO Main Terminal. Part III: Case Studies & Conclusion

HPC TCO: Cooling and Computer Room Efficiency

Harmonizing Global Metrics for Data Center Energy Efficiency

Improving Data Centers Energy Reliability & Efficiency. December 2015

Metrics for Data Centre Efficiency

Recommendation For Incorporating Data Center Specific Sustainability Best Practices into EO13514 Implementation

Knowledge Base and Research Report

ENERGY STAR Data Center Infrastructure Rating Development Update. Web Conference November 12, 2009

Getting Data Center Management Started with Profiler Tools

Reducing the Annual Cost of a Telecommunications Data Center

Energy Efficiency and Availability Management in Consolidated Data Centers

Data centre energy efficiency metrics. Existing and proposed metrics to provide effective understanding and reporting of data centre energy

Optimization of energy consumption in HPC centers: Energy Efficiency Project of Castile and Leon Supercomputing Center - FCSCL

NetApp Data Center Design

Data Centers: Definitions, Concepts and Concerns

Guidance for Calculation of Efficiency (PUE) in Data Centers

University of St Andrews. Energy Efficient Data Centre Cooling

Data Center Metering and Resource Guide. Version 1.1. July 30th, Rod Mahdavi and Steve Greenberg. Lawrence Berkeley National Laboratory

Guidance for Calculation of Efficiency (PUE) in Data Centers

Code of Conduct on Data Centre Energy Efficiency. Endorser Guidelines and Registration Form. Version 3.0.0

AEGIS DATA CENTER SERVICES POWER AND COOLING ANALYSIS SERVICE SUMMARY

How to Build a Data Centre Cooling Budget. Ian Cathcart

Building a data center. C R Srinivasan Tata Communications

Data Center Energy Profiler Questions Checklist

Potpourri Track Green IT. Colin Martin Solutions Architect, Cisco Systems Inc.

Hot Air Isolation Cools High-Density Data Centers By: Ian Seaton, Technology Marketing Manager, Chatsworth Products, Inc.

Overview of Green Energy Strategies and Techniques for Modern Data Centers

ENERGY STAR for Data Centers

BCA-IDA Green Mark for New Data Centres Version NDC/1.0

Minimising Data Centre Total Cost of Ownership Through Energy Efficiency Analysis

DATA CENTERS: AN ACCOUNT OF FEDERAL INITIATIVES AND DATA CENTER ASSESSMENTS FOR FACILITY MANAGERS. David Cosaboon, LEED AP O+M

Transcription:

Data Center Energy Use, Metrics and Rating Systems Steve Greenberg Energy Management Engineer Environmental Energy Technologies Division Lawrence Berkeley National Laboratory October 31, 2007

Today s s Agenda Introduction Energy Usage in Data Centers Opportunities for Improvement Selecting a Performance Metric Rating Systems Implementing a Metric Next Steps EETD DivRev 2004 page 2

The Data Center Challenge Data Centers 15-40x the energy intensity of typical office buildings A single rack of servers can be 20 kw $17k per year (at $.10/kWh) per rack Hundreds of racks per center Where are the opportunities? 25 data centers benchmarked EETD DivRev 2004 page 3

Typical Data Center Design Electricity Flows in Data Centers HVAC system local distribution lines lights, office space, etc. uninterruptible load to the building, 480 V UPS PDU computer racks computer equipment backup diesel generators UPS = Uninterruptible Power Supply PDU = Power Distribution Unit; EETD DivRev 2004 page 4

Data Center Metrics High-level IT/total useful work/total Subsystem Power distribution HVAC Lighting Facility performance (other than energy) EETD DivRev 2004 page 5

High-level Facility Metrics E.g. Green Grid, PUE and DCiE Source: The Green Grid Data Center Power Efficiency Metrics. 2007. Used with permission EETD DivRev 2004 page 6

High-level Facility Metrics E.g. Uptime Institute: Site Infrastructure Power Overhead Multiplier (SI-POM) = Total/IT Source: Four Metrics Define Data Center Greenness, Uptime Institute, 2007. EETD DivRev 2004 page 7

Percentage of electricity delivered to IT equipment IT Power to Total Data Center Power 0.80 0.70 Average.57 0.60 0.50 Ratio 0.40 0.30 0.20 Higher is better 0.10 0.00 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 Data Center Number Source: LBNL Benchmarking EETD DivRev 2004 page 8

Total Power/IT Power Total Data Center Power/IT Power 3.50 3.00 Average 1.83 2.50 Ratio 2.00 1.50 1.00 0.50 0.00 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 Center Number Lower is better Source: LBNL Benchmarking EETD DivRev 2004 page 9

Other Data Center Metrics Watts per square foot Power distribution: UPS efficiency, IT power supply efficiency Uptime: IT Hardware Power Overhead Multiplier (ITac/ITdc) HVAC IT total/hvac total Fan watts/cfm Pump watts/gpm Chiller plant (or chiller or overall HVAC) kw/ton Lighting watts/square foot ANCIS: Rack cooling index (fraction of IT within recommended temperature range) ANCIS: Return temperature index (RAT-SAT)/ITΔT EETD DivRev 2004 page 10

IT equipment load density IT Equipment Load Intensity 100 90 80 70 2005 Benchmarks Ave. ~ 52 Watts/sq. ft. 60 50 40 2003 Benchmarks Ave. ~ 25 30 20 10 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 Data Center Number EETD DivRev 2004 page 11

HVAC system effectiveness We observed a wide variation in HVAC performance HVAC Effectiveness Index Ratio of IT Equipment Power to HVAC Power 4.0 3.5 3.0 2.5 2.0 1.5 1.0 0.5 0.0 1 2 3 4 5 6 7 8 9 10 11 12 14 16 17 18 19 20 21 22 Data Center Number EETD DivRev 2004 page 12

Efficiency of Information Technology Power Supplies and Uninterruptible Power Supplies % Efficiency 85% 80% 75% 70% 65% 60% 55% Average of All Servers 50% 45% 0% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% % of Nameplate Power Output Power supplies in IT equipment generate much of the heat. Highly efficient supplies can reduce IT equipment load by 15% or more. UPS efficiency also varies a lot. (Do they need the same environment as the IT equipment or can their conditions be relaxed?) Efficiency Factory Measurements of UPS Efficiency (tested using linear loads) 100% 95% 90% 85% 80% Flywheel UPS Double-Conversion UPS 75% Delta-Conversion UPS 70% 0% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% Percent of Rated Active Power Load EETD DivRev 2004 page 13

Summary of Opportunities for Energy Efficiency Air management Right-sizing Central plant optimization Efficient air handling Free cooling Humidity control UPSs and power supplies On-site generation Liquid cooling Design and M&O processes EETD DivRev 2004 page 14

Benchmarking for Energy Performance Improvement Energy benchmarking can be effective in helping to identify better performing designs and strategies. As new strategies are implemented (e.g. liquid cooling), energy benchmarking will enable comparison of performance. EETD DivRev 2004 page 15

Rating Systems for Energy Efficient Data Centers Options: Rating system for new data centers based on design criteria Recognition program for upper quartile energy efficient performance for existing data centers Performance label for existing data centers, with requirement for continuous improvement EETD DivRev 2004 page 16

Rating system based on design criteria Model: LEED-New Construction Labs21 developed a LEED-based rating system for laboratories basis for proposed LEED for Labs LBNL is working with the California Energy Commission on creating credits for data centers Principle focus on energy efficiency Secondary focus on site, materials, water, indoor environment Must achieve a minimum number of points to be certified Documentation required for each point Additional levels of achievement possible Does not address post-construction performance EETD DivRev 2004 page 17

Recognition program for energy efficient performance Model: ENERGY STAR for Buildings Would need statistical model for existing data centers that included process as well as building performance Exclusive focus on energy efficiency Performance rating of 75 points on a scale of 1-100 based on statistical data Application requires Company to benchmark itself against performance index Professional engineer verifies and prepares statement of performance Label is good for one year Reapplication required to maintain ENERGY STAR EETD DivRev 2004 page 18

Performance label for continuous improvement Model: Facility certification for energy efficiency Under development for industrial plants- 2009 pilot Model suitable for existing data centers Comprehensive for processes and building Exclusive focus on energy efficiency Certification requires: Compliance with energy management standard Minimum implementation of recommendations that meet company IRR 5% energy intensity reduction over 2 years Verification of energy savings required Re-certification every 3 years; 7.5% energy intensity reduction requirement EETD DivRev 2004 page 19