SIRIUS Modular System



Similar documents
Siemens AG Highly flexible system-based switching, protecting and starting. SIRIUS Modular System SIRIUS. Answers for industry.

Protection Equipment

3RV Motor Starter Protectors up to 100 A

Low Voltage Controls & Distribution

Certificate of Compliance

SENTRON Switching and Protection Devices Air Circuit Breakers

Industrial Communication

Switching Devices Contactors and Contactor Assemblies Special Applications

How can a charging station for electric vehicles be set up simply and safely?

AF / AF09Z stack 3-pole Contactors AC / DC Operated - with Screw Terminals

C E R T I F I C A T E O F C O M P L I A N C E

3RT1015-1BB41 CONTACTOR, AC-3 3 KW/400 V,

IEC style contactors - long electrical and mechanical life Complete range from mini-contactors to 630 Amp i n d u c t i ve AC3 ra t i n g s Wide

Mini Motor Contactor J7KNA Main contactor Accessories Approved Standards Standard Guide No (US,C) Ordering Information tage Model Number Legend gear

MasterINTERFACE 39 Series - Relay interface modules

Controls Solid-State Switching Devices

What ensures easy and fast wiring?

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N

Circuit Breakers. Next Generation of Protection Capabilities

SUBJECT: How to wire a motor starter Number: AN-MC-004 Date Issued: 2/08/2005 Revision: Original

Products and solutions for lifting systems

Manual Motor Starter MS 116 up to 16 A Technical Data

Products and solutions for pumping, irrigation and piping

NF71E-.. / NFZ71E-.. Contactor Relays AC / DC Operated - with Screw Terminals

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

Safety automation solutions

Relés e Contatores de Estado Sólido SIRIUS

Application/Connection Examples

AuCom s IMS2 soft starters are a total motor starting solution, combining highlevel functionality with ease of use:

MasterINTERFACE 39 Series - Relay interface modules

Unified requirements for systems with voltages above 1 kv up to 15 kv

5SV Residual Current Protective Devices

Manual motor starter MS116

E-STOP relays, safety gate monitors

Permissible ambient temperature Operation Storage, transport

Electronic overload relay EF19 and EF45

SIRIUS Soft Starters

D-Line Contactors, Overload Relays and Accessories

Safety Relays ESM/ESM-F

Products and solutions for machine builders (OEM) 100% electricity

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

Type: DILM115(RAC240) Article No.: Sales text Contactor,55kW/400V,AC operated. Ordering information

R.C.C.B. s two-pole LEXIC

Quick Connect. quick - simple - efficient.

Electronic timer CT-VBS OFF-delayed without auxiliary voltage, for DC contactors Data sheet

Multi-talented. Valve and valve terminal series VG

Section 5. IEC Power Devices. Control Catalog 5-1

HERZ-Thermal Actuators

SIMATIC S Getting Started for First Time Users. Order No.: 6ZB5310-0NC02-0BA0 04/2007 A5E

Parameterization, Configuration and Visualization with SIRIUS

Type-Tested Power Distribution Board 8PT with Rear Busbars. sivacon

R4D0-FB-IA* FieldBarrier. Features. Assembly. Function. Connection IN + - S OUT Spur 2. Spur 1. Zone 1. Zone 0

Number 1 in efficiency

40.3. Control Relays and Timers

C441 series communication modules Accessories for electronic overload relays and soft starters. Monitoring and control made simple

RY2 miniature industrial relays

Figure 1 - Crydom 3RHP Three-phase Hybrid Solid State Contactor. Crydom Inc.

UniGear ZS1. Medium voltage, arc proof, air insulated switchgear for primary distribution

Remote Monitoring and REC 501 Control Unit Product Guide

Bulletin 150 Smart Motor Controllers SMC-3 Smart Motor Controller

Micro Contactors. Micro Contactor Relays. Micro Contactors With Solder Pins. Coil voltages. Micro Reversing Contactor. Technical Data.

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

38 Series - Relay interface modules A

PSR The compact range Description

EDI Distributor Control Interface Wiring and Setup Instructions

38 Series - Relay interface modules A

Safety along the complete line: SIRIUS 3SE7 cable-operated switches. sirius COMMANDING & SIGNALING

ISIO 200. Binary Input/Output (I/O) Terminal with IEC Interface

Preventa Machine Safety Products

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

Low voltage Direct Current Network. Compact NSX DC PV. Circuit breakers and switch disconnectors for solar application.

SITOP power supply. Technical data. SITOP Power Supply. Answers for industry.

Bulletin 150 SMC Flex Smart Motor Controller Specifications

Wiring diagrams. Compact NSX. Contents

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start * see variants. Applications.

CONFIGURABLE SAFETY RELAYS

Electronic overload relay EF65, EF96 and EF146

Single-phase ( V) voltage monitoring: Undervoltage Overvoltage Window mode (overvoltage + undervoltage) Voltage fault memory selectable

Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages

Modular I/O System Analog and Digital Interface Modules

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

Your automation should be permanently supplied Our compact PROeco power supplies offer that as part of an economical concept Let s connect.

IZM ACB/Circuit-breakers. Robust safety. Extract from Main Catalogue HPL2010 IZM26 Circuit-breakers IN26 Switch-disconnectors

General Purpose, Interposing, Solid-State and Specialty Relays. Bulletin 700

Siemens AG 2011 SINAMICS V60. The perfect solution for basic servo applications. Brochure May 2011 SINAMICS. Answers for industry.

THERMAL MANAGEMENT SOLUTIONS

Tmax MCCBs. Molded case circuit breakers. Tmax

BETA Protecting SITOR Semiconductor Fuses

Catalog. Arc Guard System TM TVOC-2

ALARM ANNUNCIATOR ME INSTRUCTION MANUAL

4 non-safe digital I/O channels 2 IO-Link Master V1.1 slots. Figure 1. Figure 2. Type code. TBPN-L1-FDIO1-2IOL Ident no

3K Load-Break Switches The Program for Safety and Performance. sentric

PRODUCT GUIDE. SL Medium Voltage IEC Vacuum Contactors

Example of use: Fuse for a solenoid valve. If the fuse is defective, no information is sent to the electronic component.

Power Supplies 3. SDN-P DIN Rail Series

INSTALLATION GUIDE. Card Reader & Controller with KIM Swipe Reader for Solitaire 850 / 950 / 850L Learnlok PK2930

mecotron Safety relay ESTOP-2 For emergency stop monitoring

LENORD. +BAUER... automates motion. PowerDRIVE-Positioning GEL 6109 Compact positioning drive for installation situations with limited space

Transcription:

Highly flexible system-based switching, protecting and starting. SIRIUS Modular System www.siemens.com/sirius

Everything for the electrical cabinet: SIRIUS Modular System. Contents SIRIUS Modular System Components Switching and Protection Device Combinations Comfortable Power Infeed and Distribution 9 Press Shop Master control room Electromechanical Switching Devices for the Fuseless Assembly of Load Feeders up to 7. kw Size S00 Selection and Ordering Data: Circuit Breaker, Contactor with Overload Relay Circuit Breaker, Contactor with Current Monitoring Relay 0 0 Power distribution Body Shop Paint Shop Final Assembly Powertrain/ Assembly Circuit Breaker, Soft Starter with Current Monitoring Relay Circuit Breaker, Solid-State Switching Device with Current Monitoring Relay Electromechanical Switching Devices for the Fuseless Assembly of Load Feeders up to. kw Size S0 Selection and Ordering Data: Circuit Breaker, Contactor, Overload Relay Circuit Breaker, Contactor with Current Monitoring Relay 6 7 7 Circuit Breaker, Soft Starter with Current Monitoring Relay Assembly of Direct-On-Line and Reversing Starters up to kw Size S Selection and Ordering Data 0 Assembly of Direct-On-Line and Reversing Starters up to kw Size S Selection and Ordering Data Size S6, S0 and S Selection and Ordering Data Pressing, equipping, transporting. These functions run in many automated production environments. You ll find everything that you need to switch, protect and start motors with the extensive portfolio of the modular SIRIUS system. Everything. Easy. SIRIUS Fuseless Load Feeders Selection and Ordering Data: Direct-On-Line Starters (Completely Pre-Assembled Load Feeders, Compact Starters) Reversing Starters (Completely Pre-Assembled Load Feeders, Compact Starters) Communication Connection (IO-Link / AS-Interface masters, contactors, function modules for Mounting on RT Contactors and for Connection to the Control, Compact Starters) 6 7 Infeed Systems For Compact Starters, Load Feeders, -Phase Busbars, US Busbar Adapters Accessories Selection and Ordering Data: Circuit Breakers Contactors Overload Relays, Current Monitoring Relays 6 0 Service & Support

Everything. System-based. SIRIUS Modular System. How to realize fast, easy, flexible and space-saving control cabinet assembly? With the unique SIRIUS modular system, which offers everything required for the switching, protection and starting of motors and systems. It comprises a modular range of standard components up to 0 kw / 00 V in only seven optimally matched sizes which can be easily combined and utilize largely identical accessories. Switching technology made easy! The permanent advancement and continuous innovation of SIRIUS optimally prepare our customers for current and future requirements and provide them with efficient solutions. All components of the SIRIUS modular system are characterized by their space-saving design and high degree of flexibility. Configuration, installation, wiring and maintenance can be realized easily and in minimum time. No matter whether you want to assemble load feeders with circuit breakers or overload relays, contactors / solid-state contactors, reversing contactors or soft starters SIRIUS offers the suitable product for every application. Thanks to the latest innovations of sizes S00 and S0 up to 0 A, the new SIRIUS modular system now offers even more functional diversity: Circuit breakers SENTRON VL In addition to the innovated basic components (such as contactors, circuit breakers and overload relays), the innovated SIRIUS modular system offers unprecedented highlights: Contactors Overload relays Feeder combinations which can be completely plug-connected without tools thanks to consistently implemented spring-loaded connection system - and -phase RR current monitoring relays for direct mounting on contactors RA7 and RA function modules which can be plugged onto contactors for the easy assembly of direct-on-line, reversing and star-delta starters and for connection to the control via AS-Interface or IO-Link with minimized wiring Soft starters S00 S0 S S S6 S0 S

Overview of the Numerous Advantages Offered by the SIRIUS Modular System With its manifold components, the SIRIUS modular system covers various functions for control cabinet applications and offers numerous advantages in terms of assembly and handling, application monitoring, connection to the control as well as planning and configuration. Assembly and handling: Reduced wiring expenditures and fault avoidance with maximum flexibility Load feeders: Easy realization with standard devices up to 0 kw / 00 V Modular system: All components are matched and can be combined Versions and sizes: Efficiency and flexibility with 7 compact sizes Accessories: Minimum variance with integrated accessories Assembly: Fast commissioning, short setup times, easy wiring Mounting: Permanently safe mounting with screw-type or easy plug-in connection system connection system: Fast and safe connection, vibrationproof and with zero maintenance Reduced wiring: Considerably reduced number of line connections thanks to plug-in connection system and IO-Link or AS-Interface Application control: Improved operational reliability and system availability Maintenance: Extremely long service life, low maintenance and reliability Application monitoring: Flexibly integrated in the feeder thanks to current monitoring relay Connection to the control: Optimum integration in the automation environment Communication: Standardized connection to AS-Interface, IO-Link and PROFIBUS DP possible Planning and configuration: Eased system planning and documentation Configuration: Easy and fast thanks to comprehensive CAx data provision Service: Short delivery periods also for spare parts thanks to worldwide logistics network Environment: Environmentally compatible production and materials, recyclability Design: Clear and ergonomic, awarded with the if Product Design Award Configurator: For easy product selection, incl. accessories Global applicability: Thanks to comprehensive approvals

Switching. Protecting. Starting. The components of the SIRIUS Modular System. Far more than ON/OFF: SIRIUS RV circuit breakers SIRIUS RV circuit breakers (MSP) are compact, current-limiting circuit breakers. They guarantee safe reliable shutdown when short circuits occur and protect loads and plants against overload. Furthermore, they are suitable for operationally switching load feeders with a low operating frequency and safely disconnecting the plant or system from the line supply when service is been carried out or changes are being made. SENTRON VL circuit breakers are suitable for applications above 00 A. As infeed and load feeder breaker, they protect plants and motors against short circuit and overload. Rugged and reliable: SIRIUS RT contactors Due to their extremely high ruggedness and optimum contact reliability, our contactors switch with supreme confidence. Furthermore, compact electrical cabinets can be configured with high packing densities. The reason for this is that the auxiliary switch blocks and solenoid protective circuitry are located within the envelope contours of the contactors. This makes it easier to expand the system and saves considerable space in the electrical cabinet. With size S00 and S0 contactors, the auxiliary switches are already integrated in the enclosure. Tripping when things get tough: SIRIUS RU and RB overload relays The overload relays of the SIRIUS family, available as either thermal or solid-state versions, protect loads connected to the main circuit, as a function of the current, and also protect other switching and protective devices in the particular load feeder. The solid-state SIRIUS RB overload relays guarantee seamless motor and plant protection from 0. A to 60 A. Due to the wide setting ranges, the current range is covered with a minimum number of versions. Easy application monitoring: SIRIUS RR current monitoring relays The SIRIUS current monitoring relays not only monitor the motor, but the entire system or driven process for overcurrent and undercurrent, cable breakage and phase failure. For example, load shedding or overload of an application is promptly detected and signaled at an early stage. Sizes S00 and S0 of the RR current monitoring relay are directly integrated in the load feeder. They simply have to be plugged onto the contactor: Click n go. Gentle starting: SIRIUS RW soft starters SIRIUS RW soft starters offer a seamless range that covers all standard and high-feature motor starting applications. They can be used in the widest range of applications to exploit the advantages of soft starting for the easy and efficient realization of optimum machine concepts. The compact two-phase-controlled RW0 facilitates efficient and spacesaving soft starting up to kw (with 00 V). The RW0 additionally offers soft stopping as well as integrated intrinsic device and motor protection functions, thanks to which an additional overload relay is unnecessary. Device versions up to a rating of kw (with 00 V) are available: Thermistor motor protection evaluation, 00 600 V.

Switching. Protecting. Starting. The components of the SIRIUS Modular System. 6 SIRIUS contactor screw connection SIRIUS contactor spring-loaded connection SIRIUS contactor ring cable lug connection Competent control of high switching frequencies: SIRIUS RF solid-state contactors SIRIUS solid-state contactors (size S0) for motor switching offer an almost unlimited service life even under harsh conditions and with high switching frequencies. The three-phase solid-state contactors switch motors up to 7. kw in an absolutely noise-free manner. A special reversing contactor version facilitates direction of rotation changes of motors up to kw. The compact devices in or 90 mm width can be combined with our circuit breakers, current monitoring relays or solidstate overload relays. This supports the fast and easy assembly of fuseless and fused motor feeders. Compact switching and protection with comprehensive additional functions: RA6 compact starters Equipped with the functions of a circuit breaker, a contactor and a solid-state overload relay, the compact starter offers maximum reliability and minimum variance as direct-online or reversing starter up to A. Safe disconnection upon the starter s end of service life offers an additional advantage in terms of system availability. Reduced wiring in the main circuit thanks to the brilliantly simple infeed system, incl. PE connection, and in the control circuit thanks to optional AS-Interface connection or integrated IO-Link interface supports the rapid assembly of complete feeder groups. The devices incorporation in the Totally Integrated Automation concept and pre-defined icon blocks for visualization facilitate the output of significant device diagnostics without the normally required configuration expenditures. Fast, reliable and user-friendly: spring-loaded technology For the first time, the entire S00/S0 range is available with spring-loaded connection system both in the main and control circuit. This accelerates device connection and offers maximum operational reliability. The outstanding ease of wiring ensures rapid mounting. The gas-tight clamp connection s vibration resistance represents a further advantage. In addition, this connection system offers maximum contact reliability even under the harshest of conditions. The frequently required re-tightening of connection terminals is thus done away with. A special bonus: Also the connecting modules for direct-on-line, reversing and star-delta starters are available with spring-loaded connection system to support the mounting of complete feeders without tools. Maximum connection flexibility Of course, all components of the SIRIUS modular system are also available with the screw-type connection system largely even with ring cable lug for special requirements, e.g. mechanical engineering applications in the semi-conductor industry.

Switching. Protecting. Starting. The components of the SIRIUS Modular System. Straight ahead: The RA direct starter Phases interchanged: The RA reversing starter Two stages one start: The RA star-delta combination Ready for immediate use: Pre-wired SIRIUS load feeders Load feeders start loads using a combination of protective and switching functions. Generally, a multiple number of components is required to implement every type of starter. In order to reduce time and costs and especially to minimize downtimes we offer you a wide range of pre-wired starter solutions: Direct starters up to kw the optimum starter combination for all motors. For high switching frequencies with solid-state contactors up to 7. kw. Reversing starters up to kw the matching combination for reversing motors. Solid-state reversing contactors can be used for applications with high switching frequencies up to kw. Wye-delta* combinations up to 7 kw the solution for running-up motors in stages. Soft starters when soft starting and stopping is required (soft ramp-down as of RW0). An almost unlimited number of further tested combinations can be easily assembled from the individual components. The SIRIUS Configuration manual offers selection support: Available under order number ZX0-0RA-AB0 or for download via www.siemens.com/industrial-controls/support 7

Combination of switching and protective devices Electromechanical controls Fuse with contactor and overload relay Motor starter protector for motor protection and contactor Motor starter protector for motor protection with overload relay function and contactor Starter motor starter protector, contactor and overload relay Compact Starter Motor starter protector for motor protection, contactor and current monitoring relay Motor starter protector for motor protection with overload relay function, contactor and current For details, see:* See p., 7, 6 See p., 7 See p. 6, 7, 0 See p., 7 Short circuit Switching Overload / Monitoring M M M M M M I I M Fuse-protected Non-fused Electronic controls Motor starter protector for motor protection, soft starter and current monitoring relay Starter motor starter protector, soft starter and current monitoring relay Fuse and soft starter Fuse and solid-state switching device Fuse, solid-state switching device and current monitoring relay Motor starter protector for motor protection and solid-state switching device Motor starter protector for motor protection, solid-state switching device and current monitoring device For details, see:* See p., 9 See p. 9 See p. See p. Short circuit Switching Overload / Monitoring M M M M M M M Non-fused * Fur further details and solutions not listed here, refer to the IC0 catalog Fuse-protected Non-fused

Comfortable Power Infeed and Distribution: SIRIUS RV9 and RA6 Infeed Systems Efficient and flexible power distribution The components of the SIRIUS modular system offer maximum wiring flexibility. They can be connected easily via the corresponding SIRIUS RV9 infeed system or the RA6 infeed system in conjuction with the compact starter. Both systems are respectively available for devices with screw-type and spring-loaded connection system. For connection, individual circuit breakers, complete load feeders or compact starters are simply clicked into the respective infeed system. Doing away with laborious wiring and fault risks, a complete feeder group is thus supplied with power: Click n go! Alternatively, also conventional wiring is supported: Via parallel wiring, -phase busbar or the US busbar adapter with which the SIRIUS load feeders can be directly mounted on a 60 mm busbar system. These manifold combination options facilitate the effortless realization of your individual control cabinet solution perfectly matched to your application. Design highlights Outstanding flexibility for assembly and expansions Reduced space requirements in the control cabinet thanks to very compact design Infeed optionally from the left or right with conductor cross sections of up to 70 mm Optional wiring duct between the feeders Additional integration of further -, - or -pole components via terminal block Maximum current carrying capacity of 00 A Integration of load feeders with screw-type and spring-loaded connection system High vibration resistance, particularly with switching devices featuring the spring-loaded connection system Time savings in terms of mounting thanks to easy plug-in connection system Also PE connection option with the RA6 infeed 9

Design up to 7. kw (S00), Non-fused, electromechanical switching design 0 Starter combinations of motor starter protector and contactor with overload relay Starter combinations of motor starter protector and contactor with optional current monitoring relay Type Screw connection connection Motor starter protector* Link module RA9-DA00 RA9-AA00 Contactor (AC / DC)* Overload relay* * For order numbers of basic components see tabular overview on page Type Screw connection connection Motor starter protector* Link module RA9-DA00 RA9-AA00 Contactor (AC / DC)* Overload relay* * For order numbers of basic components see tabular overview on page

Starter combinations: motor starter protector, contactor with overload relay Motor starter protector for starter protection Contactor Overload relay ) Three-phase motor 00 V/AC- Setting range of thermal overload release CLASS 0 Auxiliary contacts Control supply voltage Setting range CLASS 0 Thermal Electronic CLASS 0 [kw] [A] [A] DC V AC 0 V, 0/60 Hz [A] 0.0 0.6 RV-0AC 0 0. 0.6 RU6-0A 0 M 0.06 0. RV-0BC 0 0. 0. RU6-0B 0 0.06 0. RV-0CC 0 0. 0. RU6-0C 0 RB06-R 0 0.09 0. RV-0DC 0 0. 0. RU6-0D 0 (0. 0. A) 0.09 0. RV-0EC 0 0. 0. RU6-0E 0 0. 0. RV-0FC 0 0. 0. RU6-0F 0 0. 0.6 RV-0GC 0 0. 0.6 RU6-0G 0 0. 0. RV-0HC 0 0. 0. RU6-0H 0 RB06-N 0 0. RV-0JC 0 0.7 RU6-0J 0 (0.. A) 0.7. RV-0KC 0 NC RT0- BB RT0- AP0 0.9. RU6-0K 0 0..6 RV-AC 0 NO RT0- BB RT0- AP0..6 RU6-A 0 0.7 RV-BC 0. RU6-B 0 0.7. RV-CC 0.. RU6-C 0 RB06-P 0.. RV-DC 0.. RU6-D 0 ( A). RV-EC 0. RU6-E 0. RV-FC 0. RU6-F 0. 6. RV-GC 0. 6. RU6-G 0 RB06-S 0 RV-HC 0. RU6-H 0 ( A) 0 RV-JC 0 NC RT06- BB RT06- AP0 7 0 RU6-J 0 NO RT06- BB RT06- AP0.. RV-KC 0 NC RT07- BB RT07- AP0 9. RU6-K 0 NO RT07- BB RT07- AP0 RB06-T 0 7. 6 RV-AC 0 NC RT0- BB RT0- AP0 6 RU6-A 0 ( 6 A) NO RT0- BB RT0- AP0 ) Direct mounting on contactor, screw and spring-loaded connection possible Screw connection: connection: Screw connection: connection: Ring cable lug connection: Screw connection: B connection: C Ring cable lug connection: J Screw connection: connection: B E

Starter combinations: motor starter protector, contactor with optional current monitoring relay Motor starter protector for motor protection Contactor Current monitoring relay Three-phase motor 00 V/AC- Setting range of thermal overload release CLASS 0 Auxiliary contacts Control supply voltage [kw] [A] [A] DC V AC 0 V, 0/60 Hz [A] 0.0 0.6 0. 0.6 RV0-0AA 0 0.06 0. 0. 0. RV0-0BA 0 0.06 0. 0. 0. RV0-0CA 0 0.09 0. 0. 0. RV0-0DA 0 0.09 0. 0. 0. RV0-0EA 0 0. 0. 0. 0. RV0-0FA 0 0. 0.6 0. 0.6 RV0-0GA 0 0. 0. 0. 0. RV0-0HA 0 Measurement range Basic (analog setting) Standard (digital setting) I M 0. 0.7 RV0-0JA 0 0.7. 0.9. RV0-0KA 0 NC RT0- BB RT0- AP0 0..6..6 RV0-AA 0 NO RT0- BB RT0- AP0 0.7. RV0-BA 0 0.7... RV0-CA 0.... RV0-DA 0.. RV0-EA 0.. RV0-FA 0. 6.. 6. RV0-GA 0.6 6 RR- A 0 RR- F 0. RV0-HA 0 0 7 0 RV0-JA 0 NC RT06- BB RT06- AP0 NO RT06- BB RT06- AP0.. 9. RV0-KA 0 NC RT07- BB RT07- AP0 NO RT07- BB RT07- AP0 7. 6 6 RV0-AA 0 NC RT0- BB RT0- AP0 NO RT0- BB RT0- AP0 Screw connection: connection: Ring cable lug connection: Screw connection: connection: Ring cable lug connection: Screw connection: connection: AC/DC V: A AC/DC 0 V: W Size S00 Size S0 Size S Size S Size S6, S0, S Fuseless Load Feeders Communication Feeder Combinations Infeed System Accessories

Design up to 7. kw (S00) Non-fused, electronic switching design Starter combinations: motor starter protector, soft starter with optional current monitoring relay (for stand-alone mounting) Starter combinations: motor starter protector, solid-state switching device with optional current monitoring relay Type Screw connection connection Type Screw connection Motor starter protector * Motor starter protector * Link module RA9-BA00 RA9-GA00 Link module RA9-BA00 Soft starter * Adapter for stand-alone assembly Current monitoring relay * ) RU96-AA0 RU96-AC0 * For order numbers of basic components see tabular overview on page Solid-state contactor / solid-state reversing contactor * Adapter for stand-alone assembly Current monitoring relay * ) RU96-AA0 * For order numbers of basic components see tabular overview on page ) An adapter for stand-alone assembly is required for the application of a RR current monitoring relay on a RW0/0 soft starter. The current monitoring relay must not be active during the start-up and ramp-down phase (phase control). For RW0: The RR monitoring relay is to be enabled via an upstream timing relay after soft start-up completion. For RW0: The RR monitoring relay is to be enabled/disabled via the BYPASS output (start-up detection). ) An adapter for stand-alone assembly is required for the application of a RR current monitoring relay on a RW0/0 soft starter. The current monitoring relay must not be active during the start-up and ramp-down phase (phase control). For RW0: The RR monitoring relay is to be enabled via an upstream timing relay after soft start-up completion. For RW0: The RR monitoring relay is to be enabled/disabled via the BYPASS output (start-up detection).

Starter combinations: motor starter protector, soft starter with optional current monitoring relay (for stand-alone mounting) Motor starter protector Soft starter ) Current monitoring relay Three-phase motor 00 V/AC- Setting range of thermal overload release CLASS 0 Rated operating current Control supply voltage Measurement range Basic (analog setting) Standard (digital setting) [kw] [A] [A] [A] AC/DC V AC/DC 0 0 V [A] M 0.0 0.6 0. 0.6 RV0-0AA^ 0 0.06 0. 0. 0. RV0-0BA^ 0 0.06 0. 0. 0. RV0-0CA^ 0 0.09 0. 0. 0. RV0-0DA^ 0 0.09 0. 0. 0. RV0-0EA^ 0 0. 0. 0. 0. RV0-0FA^ 0 0. 0.6 0. 0.6 RV0-0GA^ 0 0. 0. 0. 0. RV0-0HA^ 0.6 RW0- BB0 RW0- BB 0. 0.7 RV0-0JA^ 0 0.7. 0.9. RV0-0KA^ 0 0..6..6 RV0-AA^ 0 0.7. RV0-BA^ 0 0.7... RV0-CA^ 0.... RV0-DA^ 0.. RV0-EA^ 0.. RV0-FA^ 0 6. RW0- BB0 RW0- BB. 6.. 6. RV0-GA^ 0.6 6 RR- A 0 RR- F 0. RV0-HA^ 0 9 RW06- BB0 RW06- BB 0 7 0 RV0-JA^ 0.. 9. RV0-KA^ 0. RW07- BB0 RW07- BB 7. 6 6 RV0-AA^ 0 7.6 RW0- BB0 RW0- BB ) Rated operating voltage 00... 0 V Screw connection: connection: Ring cable lug connection: Screw connection: connection: Screw connection: connection: AC/DC V: A AC/DC 0 V: W

Starter combinations: motor starter protector, soft starter with optional current monitoring relay (for stand-alone mounting) Motor starter protector Solid-state contactor ) Current monitoring relay Three-phase motor 00 V/AC- Setting range of thermal overload release CLASS 0 Rated operating current Control supply voltage [kw] [A] [A] [A] DC V AC 0 0 V, 0/60 Hz [A] Measurement range Basic (analog setting) Standard (digital setting) M 0.0 0.6 0. 0.6 RV0-0AA^ 0 0,06 0. 0. 0. RV0-0BA^ 0 0,06 0, 0. 0. RV0-0CA^ 0 0,09 0. 0. 0. RV0-0DA^ 0 0,09 0. 0. 0. RV0-0EA^ 0 0. 0. 0. 0. RV0-0FA^ 0 0, 0.6 0. 0.6 RV0-0GA^ 0.6 6 RR- A 0 RR- F 0 0, 0. 0. 0. RV0-0HA^ 0 0, 0.7 RV0-0JA^ 0. RF0- BB0 RF0- BB 0.7. 0.9. RV0-0KA^ 0 0..6..6 RV0-AA^ 0 0,7. RV0-BA^ 0 0,7... RV0-CA^ 0.... RV0-DA^ 0,. RV0-EA^ 0,. RV0-FA^ 0. 6.. 6. RV0-GA^ 0 6 RR- A 0 ) RR- F 0 ). RV0-HA^ 0 0 7 0 RV0-JA^ 0 9. RF0- BB0 ) RF0- BB ).. 9. RV0-KA^ 0. RF- BB0 ) RF- BB ) 7. 6 6 RV0-AA^ 0 6 RF6- BB0 ) RF6- BB ) ) Overall width 90 mm ) Rated operating voltage Ue... 0 V ) Can be directly mounted on solid-state contactor with screw connection Screw connection: connection: Ring cable lug connection: Screw connection: connection: Solid-state reversing contactor ). RF0-BD0 RF0-BD. RF0-BD0 RF0-BD Screw connection: connection: AC/DC V: A AC/DC 0 V: W 7. RF0-BD0 ) RF0-BD ) Size S00 Size S0 Size S Size S Size S6, S0, S Fuseless Load Feeders Communication Feeder Combinations Infeed System Accessories

Design up to. kw (S0) Non-fused, electromechanical switching design 6 Starter combinations: motor starter protector, contactor and overload relay Starter combinations: motor starter protector, contactor with optional current monitoring relay Typ Screw connection connection Motor starter protector * Type Screw connection connection Motor starter protector * Link module ) AC DC RA9-AA00 RA9-BA00 RA9-AA00 RA9-AA00 Link module ) AC DC RA9-AA00 RA9-BA00 RA9-AA00 RA9-AA00 Contactor * Contactor * Overload relay * Current monitoring relay * * For order numbers of basic components see tabular overview on page 7 ) Only suitable up to A * For order numbers of basic components see tabular overview on page 7 ) Only suitable up to A

Starter combinations: motor starter protector, contactor and overload relay Motor starter protector for starter protection Contactor Overload relay M Three-phase motor 00V/AC- Thermal overload release Aux. contacts Control supply voltage Setting range CLASS 0 Thermal [kw] [A] DC V 0 V AC UC (AC 0/60 Hz/DC) [A] [A] 7. 6 RV-AC 0 NO+NC RT0- BB0 RT0- AP00 RT0- N 0 6 RU6-A 0 Setting range CLASS 0 Electronic 7. 0 RV-BC 0 0 RU6-B 0 6 RB06 -Q 0 RV-CC 0 NO+NC RT06- BB0 RT06- AP00 RT06- N 0 7 RU6-C 0 RV-DC 0 0 RU6-D 0 RV-NC 0 NO+NC RT07- BB0 RT07- AP00 RT07- N 0 RU6-N 0 0 0 RB06- V 0 RV-EC 0 7 RU6-E 0. 6 RV-PC0 NO+NC RT0- BB0 RT0- AP00 RT0- N 0 0 6 RU6-P 0. 0 RV-FC0 0 RU6-F 0 Starter combinations: motor starter protector, contactor with optional current monitoring relay I M Three-phase motor 00V/AC- Motor starter protector f. motor protection Contactor Current monitoring relay Thermal overload release Screw connection: connection ) : Aux. contacts Control supply voltage [kw] [A] [A] DC V 0 V AC UC (AC 0/60 Hz/DC) [A] 7. 6 6 RV0-AA 0 NO+NC RT0- BB0 RT0- AP00 RT0- N 0 7. 0 0 RV0-BA 0 7 RV0-CA 0 NO+NC RT06- BB0 RT06- AP00 RT06- N 0 Measurement range Basic (analog setting) Standard (digital setting) 0 RV0-DA 0 0 RR- A 0 RR- F 0 RV0-NA 0 NO+NC RT07- BB0 RT07- AP00 RT07- N 0 7 RV0-EA 0. 6 0 6 RV0-PA0 NO+NC RT0- BB0 RT0- AP00 RT0- N 0. 0 0 RV0-FA0 Screw connection: connection: Ring cable lug connection ) : UC V: B UC 9 0 V: F UC 00 0 V: P Screw connection: B connection: C Ring cable lug connection: J Screw connection: B connection: E ) Max. A ) Voltages on request Screw connection: connection ) : Ring cable lug connection ) : Screw connection: connection: Ring cable lug connection ) : UC V: B UC 9 0 V: F UC 00 0 V: P Screw connection: connection: AC/DC V: A AC/DC 0 V: W Size S00 Size S0 Size S Size S Size S6, S0, S Fuseless Load Feeders Communication Feeder Combinations Infeed System Accessories 7

Design up to. kw (S0) Non-fused, electronic switching design Starter combinations: motor starter protector, RW0 soft starter with optional current monitoring relay (for stand-alone mounting) Starter combinations: Motor starter protector, RW0 soft starter (integrated electronic overload relay) with optional current monitoring relay (for stand-alone mounting) Type Motor starter protector * Screw connection connection Link module ) RA9-BA00 RA9-GA00 Type Motor starter protector * Screw connection connection Link module ) RA9-BA00 RA9-GA00 Soft starter * Soft starter * Adapter for stand-alone assembly Current monitoring relay * ) RU96-AA0 RU96-AC0 * For order numbers of basic components see tabular overview on page 9 Adapter for stand-alone assembly Current monitoring relay * ) RU96-AA0 RU96-AC0 * For order numbers of basic components see tabular overview on page 9 ) Only suitable up to A ) An adapter for stand-alone assembly is required for the application of a RR current monitoring relay on a RW0/0 soft starter. The current monitoring relay must not be active during the start-up and ramp-down phase (phase control). For RW0: The RR monitoring relay is to be enabled via an upstream timing relay after soft start-up completion. For RW0: The RR monitoring relay is to be enabled/disabled via the BYPASS output (start-up detection). ) Only suitable up to A ) An adapter for stand-alone assembly is required for the application of a RR current monitoring relay on a RW0/0 soft starter. The current monitoring relay must not be active during the start-up and ramp-down phase (phase control). For RW0: The RR monitoring relay is to be enabled via an upstream timing relay after soft start-up completion. For RW0: The RR monitoring relay is to be enabled/disabled via the BYPASS output (start-up detection).

Starter combinations: motor starter protector, RW0 soft starter with optional current monitoring relay (for stand-alone mounting: see combination options on page ) Motor starter protector for motor protection Soft starter ) Current monitoring relay Three-phase motor 00 V/AC- Setting range, thermal overload release CLASS 0 Rated operating current Control supply voltage [kw] [A] [A] [A] AC/DC V AC/DC 0 0 V [A] Measurement range Basic (analog setting) Standard (digital setting) M 7 RV0-CA 0 RW06- BB0 RW06- BB 0 RV0-DA 0 RV0-NA 0 RW07- BB0 RW07- BB 7 RV0-EA 0 0 RR- A 0 RR- F 0. 6 0 6 RV0-PA0 RW0- BB0 RW0- BB. 0 0 RV0-FA0. 0 0 RV0-FA0 RW06- BB0 RW06- BB Starter combinations: motor starter protector, RW0 soft starter (integrated electronic overload relay) with optional current monitoring relay (for stand-alone mounting: see combination options on page ) Motor starter protector for starter protection Soft starter ) Current monitoring relay Three-phase motor 00 V/AC- Setting range of thermal overload release CLASS 0 Rated operating current Control supply voltage Measurement range Basic (analog setting) Standard (digital setting) [kw] [A] [A] [A] AC/DC V AC/DC 0 0 V [A] M.. RV-KC 0. RW0- BB0 RW0- BB 7. 6 RV-AC 0 7. 0 RV-BC 0 RV-CC 0 RW06- BB0 RW06- BB RV-DC 0 0 RR- A 0 RR- F 0 RV-NC 0 RV-EC 0 RW07- BB0 RW07- BB. 6 RV-PC0. 0 RV-FC0 RW0- BB0 ) Operating voltage 00 0 V Screw connection: connection: up to A Screw connection: connection: Screw connection: connection: AC/DC V: A AC/DC 0 V: W Size S00 Size S0 Size S Size S Size S6, S0, S Fuseless Load Feeders Communication Feeder Combinations Infeed System Accessories 9

Design S up to kw 0 Direct start Leistungsschalter Baugröße S Hutschienenadapter RA9 -AA00 Reversing start 6 7 Assembly kit for busbar mounting 0 mm: RA9 -C 60 mm: RA9 -D comprising: Verbindungsbaustein für AC: RA9 -AA00 für DC: RA9 -BA00 9 6 7 9 wiring kit busbar adapter controlgear support side module link wedges Assembly kit for rail mounting RA9 -B comprising: wiring kit Schütz Baugröße S rail adapter side modules link wedges Type Version Size S circuit breaker Link module Size S contactors For busbar mounting (alternative) Busbar adapter For rail mounting (diagram) AC DC 0 mm 60 mm RA9 -AA00 RA9 -BA00 US0 6-FP0 US 6-FP0 Rail adapter RA9 -AA00 Type Version Size S circuit breaker Size S contactors Mechanical interlock RA9 -B Link module Wiring kit: upper link module, lower link module For busbar mounting (diagram) 6 Controlgear support 7 Busbar adapter AC DC 0 mm 60 mm 0 mm 60 mm RA9 -AA00 RA9 -BA00 US0 60-AP00 US 60-AP00 US0 6-FP0 US 6-FP0 Link wedges ( = 00 wedges) US9 9-AA00 9 Side module US9 9-MB00 For rail mounting (alternative) Rail adapter RA9 -AA00 Link wedges ( = 00 wedges) US9 9-AA00

S selection and ordering data Circuit breakers (MSP) Contactor Soft starters ) Overload relays Threephase motor 00 V/AC- Setting range CLASS 0 Aux. contacts Control supply voltage Control supply voltage Rated operating current Setting range CLASS 0 Thermal Setting range Electronic ) CLASS 0 [kw] [A] [A] Ie [A] [A] [A] 9 RV0-EA0 AC 0 V, 0/60 Hz RT0-AL0 RU6-EB0 DC V RT0-BB0 AC/DC 0 0 V RW06-BB. 0 RV0-FA0 AC/DC V 0 RU6-FB0 AC 0 V, 0/60 Hz RT0-AL0 RW06-BB0 DC V RT0-BB0 AC/DC 0 0 V. 0 RB - UB0 6 RV0-GA0 RW06-BB 6 RU6-GB0 AC/DC V AC 0 V, 0/60 Hz RT06-AL0 RW06-BB0 0 0 RV0-HA0 DC V RT06-BB0 0 0 RU6-HB0 CLASS 0 0 6 CLASS 0 0 6 CLASS...0* * With ground-fault detection (activatable) and electrical remote reset ) Operating voltage 00 0 V ) For using tripping CLASS 0, please refer to the information contained in the SIRIUS Engineering Fuseless Load Feeders configuration brochure and in the catalog Size S00 Size S0 Size S Size S Size S6, S0, S Fuseless Load Feeders Communication Feeder Combinations Infeed System Accessories

Design S up to kw Direct start Reversing start 6 7 Assembly kit for rail mounting RA9 -B comprising: 7 wiring kit rail adapters 6 side modules 7 7 6 link wedges 6 7 Type Version Size S circuit breaker Link module Size S contactor AC DC RA9 -AA00 RA9 -BA00 Rail adapter RA9 -A Type Version Size S circuit breaker Size S contactors Mechanical interlock RA9 -B Link module Rail adapter 6 Side modules for rail adapters ( = 0 adapters) AC DC RA9 -AA00 RA9 -BA00 RA9 0-B 7 Link wedges ( = 00 wedges) US9 9-AA00 Wiring kit: upper link module, lower link module RA9 -A

S selection and ordering data Circuit breakers (MSP) Contactor Soft starters ) Overload relays Threephase motor 00 V/AC- Setting range CLASS 0 Aux. contacts Control supply voltage Control supply voltage Rated operating current Setting range CLASS 0 Thermal Setting range Electronic ) CLASS 0 [kw] [A] [A] Ie [A] [A] [A] 0 6 RV0-JA0 AC 0 V, 0/60 Hz RT0-AL0 6 RU6-JB0 DC V RT0-BB0 AC/DC 0 0 V 0 RW06-BB 7 67 7 7 RV0-KA0 AC/DC V 7 7 RU6-KB0 AC 0 V, 0/60 Hz RT0-AL0 0 RW06-BB0 DC V RT0-BB0 AC/DC 0 0 V 00 RB - EB0 0 70 90 RV0-LA0 0 RW06-BB 70 90 RU6-LB0 AC/DC V AC 0 V, 0/60 Hz RT06-AL0 0 RW06-BB0 0 0 00 RV0-MA0 DC V RT06-BB0 0 00 RU6-MB0 CLASS 0 0 6 CLASS 0 0 6 CLASS...0* * With ground-fault detection (activatable) and electrical remote reset ) Operating voltage 00 0 V ) For using tripping CLASS 0, please refer to the information contained in the SIRIUS Engineering Fuseless Load Feeders configuration brochure and in the catalog Size S00 Size S0 Size S Size S Size S6, S0, S Fuseless Load Feeders Communication Feeder Combinations Infeed System Accessories

S6, S0, S selection and ordering data S6 Contactor Overload relay ) Soft starter Threephase motor 00 V/AC- Electromagnetic operating mechanism Aux. switches Control supply voltage contactor Vacuum contactor Setting range Solid-state Overload relay Version Control supply voltage Rated operating current [kw] [A] [AC/DC V] [A] Ie [A] Conventional NO + NC 0 0 RT0-AP6 Electronic for V DC PLC output NO + NC 00 77 RT0-NP6 for V DC PLC output w/rlt ) NO + NC 00 77 RT0-PP with AS-i interface and RLT ) NO + NC 00 77 RT0-QP 7 0 Conventional NO + NC 0 0 RT0-6AP6 AC 0 V RW0-6BB Electronic for V DC PLC output NO + NC 00 77 RT0-6NP6 0 00 RB - FW with straight-through for V DC PLC output w/rlt ) NO + NC 00 77 RT0-6PP transformer with AS-i interface and RLT ) NO + NC 00 77 RT0-6QP 0 00 RB - FC with busbar connection AC V RW0-6BB AC 0 V 6 RW06-6BB 90 Conventional NO + NC 0 0 RT06-6AP6 AC V 6 RW06-6BB CLASS 0 0 6 Electronic CLASS 0 0 6 CLASS...0* for V DC PLC output NO + NC 00 77 RT06-6NP6 for V DC PLC output w/rlt ) NO + NC 00 77 RT06-6PP with AS-i interface and RLT ) NO + NC 00 77 RT06-6QP * With ground-fault detection (activatable) and electrical remote reset

S6 Contactor Overload relay ) Soft starter 0 Conventional NO + NC 0 0 RT06-6AP6 RT6-6AP6 Electronic for V DC PLC output NO + NC 00 77 RT06-6NP6 RT6-6NP6 0 RB 6 - GC with busbar for V DC PLC output w/rlt ) NO + NC 00 77 RT06-6PP connection with AS-i interface and RLT ) NO + NC 00 77 RT06-6QP AC 0 V 0 RW07-6BB 6 Conventional NO + NC 0 0 RT06-6AP6 RT6-6AP6 AC V 0 RW07-6BB Electronic for V DC PLC output NO + NC 00 77 RT06-6NP6 RT6-6NP6 AC 0 V 0 RW07-6BB for V DC PLC output w/rlt ) NO + NC 00 77 RT06-6PP with AS-i interface and RLT ) NO + NC 00 77 RT06-6QP 60 60 RB 6 - MC with busbar connection 60 00 Conventional NO + NC 0 0 RT066-6AP6 RT66-6AP6 Electronic for V DC PLC output NO + NC 00 77 RT066-6NP6 RT66-6NP6 for V DC PLC output w/rlt ) NO + NC 00 77 RT066-6PP with AS-i interface and RLT ) NO + NC 00 77 RT066-6QP CLASS 0 0 6 CLASS 0 0 6 CLASS...0* * With ground-fault detection (activatable) and electrical remote reset AC V 0 RW07-6BB S Contactor Overload relay ) Soft starter 0 00 Conventional NO + NC 0 0 RT07-6AP6 RT7-6AP6 Electronic for V DC PLC output NO + NC 00 77 RT07-6NP6 RT7-6NP6 AC 0 V 6 RW07-6BB for V DC PLC output w/rlt ) NO + NC 00 77 RT07-6PP with AS-i interface and RLT ) NO + NC 00 77 RT07-6QP 60 60 RB 6 - MC with busbar connection AC V 6 RW07-6BB 0 00 Conventional NO + NC 0 0 RT076-6AP6 RT76-6AP6 AC 0 V RW076-6BB CLASS 0 0 6 Electronic CLASS 0 0 6 for V DC PLC output NO + NC 00 77 RT076-6NP6 RT76-6NP6 CLASS...0* AC V RW076-6BB for V DC PLC output w/rlt ) NO + NC 00 77 RT076-6PP with AS-i interface and RLT ) NO + NC 00 77 RT076-6QP * With ground-fault detection (activatable) and electrical remote reset For applications above 00 A, SIRIUS contactors can be combined with SENTRON VL circuit breakers. For more detailed information please refer to the engineering brochure Engineering SIRIUS fuseless load feeders. ) For rated device operating voltage Ue: 00 60 V (see catalog for Ue: 00 600 V) ) For using tripping CLASS 0, please refer to the information contained in the SIRIUS Engineering Fuseless Load Feeders configuration brochure and in the catalog ) RLT: Remaining lifetime indication SENTRON VL circuit breakers are suitable for the fuseless short-circuit and overload protection of soft starters of size S6 or larger. For further information, please refer to the catalog. Size S00 Size S0 Size S Size S Size S6, S0, S Fuseless Load Feeders Communication Feeder Combinations Infeed System Accessories

Fuseless load feeders up to kw 6 Direct starter, fully preassembled, electromechanical RA direct-on-line starter RA direct-on-line starter RA6 Compact Starter Threephase motor 00 V/AC- Setting range of thermal overload release Coordination type Coordination type Setting range of thermal overload release Coordination type CPS ) M [kw] [A] [A] 0.06 0.0 0. 0. RA0-0B - S00 RA0-0B - S00 0.06 0. 0. 0. RA0-0C - S00 RA0-0C - S00 0.09 0. 0. 0. RA0-0D - S00 RA0-0D - S00 0.09 0.0 0. 0. RA0-0E - S00 RA0-0E - S00 0. 0.0 0. 0. RA0-0F - S00 RA0-0F - S00 0. 0.6 0. 0.6 RA0-0G - S00 RA0-0G - S00 0. 0.0 0. 0. RA0-0H - S00 RA0-0H - S00 0..0 0.7 RA0-0J - S00 RA0-0J - S00 0.7. 0.9. RA0-0K - S00 RA0-0K - S00 0..6..6 RA0-A - S00 RA0-A - S00 0.7.0. RA0-B - S00 RA0-B - S00 0.7... RA0-C - S00 RA0-C - S00.... RA0-D - S00 RA0-D - S00..0. RA0-E - S00 RA0-E - S00..0. RA0-F - S00 RA0-F -0 S0 ). 6.. 6. RA0-G - S00 RA0-G -0 S0 ). RA0-H - S00 RA0-H -0 S0 ) 0 7 0 RA0-J 6- S00 RA0-J 6-0 S0 ).. 9. RA0-K 7- S00 RA0-K 6-0 S0 ) 7. 6 6 RA0-A - S00 RA0-A 6-0 S0 7. 0 0 RA0-B 6-0 S0 RA0-B 6-0 S0 7 RA0-C 7-0 S0 RA0-C 7-0 S0 0 RA0-D 7-0 S0 RA0-D 7-0 S0 7 RA0-E 7-0 S0 RA0-E 7-0 S0 [A] 0. 0. RA60- A 0.. RA60- B RA60- C RA60- D RA60- E ) CPS: Control and protective switching device, IEC/EN 6097-6- ) If used in the RA6 Infeed system, please use instead of. ) Not available with spring-loaded connection system Screw connection (for mounting onto DIN rail): A connection (for mounting onto DIN rail): E Screw connection (busbar adapter): D connection (busbar adapter): H V AC/DC: B B 0 V AC: A P 0 Without terminals: 0 0 With screw connection: ) With spring-loaded connection: ) V AC/DC AC 0... 0 V AC/DC B P

Reversing starter, fully preassembled M Three-phase motor 00 V/AC- [kw] [A] [A] Setting range of thermal overload release RA reversing starter RA reversing starter Coordination type Coordination type 0.06 0.0 0. 0. RA0-0B - S00 RA0-0B - S00 0.06 0. 0. 0. RA0-0C - S00 RA0-0C - S00 0.09 0. 0. 0. RA0-0D - S00 RA0-0D - S00 0.09 0.0 0. 0. RA0-0E - S00 RA0-0E - S00 0. 0.0 0. 0. RA0-0F - S00 RA0-0F - S00 0. 0.6 0. 0.6 RA0-0G - S00 RA0-0G - S00 0. 0.0 0. 0. RA0-0H - S00 RA0-0H - S00 0..0 0.7 RA0-0J - S00 RA0-0J - S00 0.7. 0.9. RA0-0K - S00 RA0-0K - S00 0..6..6 RA0-A - S00 RA0-A - S00 0.7.0. RA0-B - S00 RA0-B - S00 0.7... RA0-C - S00 RA0-C - S00.... RA0-D - S00 RA0-D - S00..0. RA0-E - S00 RA0-E - S00..0. RA0-F - S00 RA0-F - S0 ). 6.. 6. RA0-G - S00 RA0-G -0 S0 ). RA0-H - S00 RA0-H -0 S0 ) 0 7 0 RA0-J 6- S00 RA0-J 6-0 S0 ).. 9. RA0-K 7- S00 RA0-K 6-0 S0 ) 7. 6 6 RA0-A - S00 RA0-A 6-0 S0 7. 0 0 RA0-B 6-0 S0 RA0-B 6-0 S0 7 RA0-C 7-0 S0 RA0-C 7-0 S0 0 RA0-D 7-0 S0 RA0-D 7-0 S0 RA0-N -0 S0 RA0-N -0 S0 7 RA0-E -0 S0 RA0-E -0 S0 RA6 Compact Starter Setting range of thermal overload release [A] Coordination type CPS ) 0. 0. RA60- A 0.. RA60- B RA60- C RA60- D RA60- E ) CPS: Control and protective switching device, IEC/EN 6097-6- ) If used in the RA6 Infeed system, please use instead of. ) Not available with spring-loaded connection system Screw connection (for mounting onto DIN rail) S00: A Screw connection (for mounting onto DIN rail) S0: B connection (for mounting onto DIN rail) S00: E connection (for mounting onto DIN rail) S0: F Screw connection (busbar adapter): D connection (busbar adapter): H V AC/DC: B B 0 V AC: A P 0 Without terminals: 0 0 With screw connection: ) With spring-loaded connection: ) V AC/DC AC 0... 0 V AC/DC Size S00 Size S0 Size S Size S Size S6, S0, S Fuseless Load Feeders Communication Feeder Combinations Infeed System B P Accessories 7

Communications general information and contactors Interfacing load feeders to the control system requires function modules for IO-Link or AS-i which are mounted on contactors ( V DC) with a communication interface. Depending on the version, they communicate with an IO-Link interface group or any AS-i Master. Typical layout in the environment of IO-Link IO-Link PROFIBUS or PROFINET/Ethernet IO-Link Version ET 00S electronic module, SI IO-Link (with ports for load feeders each) or ET 00S electronic module, SI SIRIUS (with ports for load feeders each) ET 00S terminal module ( mm wide) 6ES7 -GA0-0AB0 RK00-0LB00-0AA0 With screw terminal TM-ES6-A 6ES7 With spring-loaded terminal TM-EC6-A 6ES7 With Fast Connect TM-EN6-A 6ES7 ET 00S interface module for interfacing to PROFIBUS and PROFINET and more system accessories see the Industry Mall or the IKPI Catalog Mounting principle of function modules on contactors Motor Starter Protection Contactor Typical layout in the environment of AS-Interface AS-Interface AS-Interface Version CP -P communication processor for interfacing SIMATIC S7-00 to AS-Interface (AS-i Spec..0) for max. 6 load feeders Front connector, 0-pin with screw contacts Front connector, 0-pin with spring-loaded contacts DP/AS-i LINK Advanced, gateway between PROFIBUS DP and AS-Interface 6GK7-AH-0XA0 6ES79-AJ00-0AA0 6ES79-BJ00-0AA0 Single master for max. 6 load feeders 6GK-BA0 Double master for max. load feeders 6GK-BA0 IE/AS-i LINK PN IO, gateway between PROFINET and AS-Interface Single master for max. 6 load feeders Double master for max. load feeders AS-Interface power supply unit IP0 6GK-AB0 6GK-AB0 0/0 V AC A RX90-0BA00 V DC A RX90-BA00 0/0 V AC A RX90-0BA00 0/0 V AC A RX90-BA00 For more system components for AS-Interface see the Industry Mall or the IKPI Catalog Three-phase motor 00 V/AC- S00 contactor with communication interface Auxiliary contacts [kw] [A] DC V Control supply voltage 7 NC RT0- BB-0CC0 NO RT0- BB-0CC0 9 NC RT06- BB-0CC0 NO RT06- BB-0CC0. NC RT07- BB-0CC0 NO RT07- BB-0CC0 7. 6 NC RT0- BB-0CC0 NO RT0- BB-0CC0 S0 contactor with communication interface. NO+NC RT0- BB0-0CC0 7. 6 NO+NC RT0- BB0-0CC0 NO+NC RT06- BB0-0CC0 NO+NC RT07- BB0-0CC0. NO+NC RT0- BB0-0CC0 Screw connection: connection:

Function modules for mounting on RT contactors and for interfacing the control system Parallel wiring Direct-on-line start Reversing start Star-delta start ON delay RA- CW0 Wiring kit for contactors S00 RA9-AA Function module ) RA6-0EW0 OFF delay (with auxiliary voltage) RA- DW0 Wiring kit for contactors with screw connection S0 RA9-AA Wiring kit for contactors ) S00 RA9-BB Wiring kit for contactors ) S0 RA9-BB IO-Link Direct-on-line start ) ) Reversing start ) ) ) ) ) ) Star-delta start Function module RA7- AA00 Function module RA7- BA00 Function module RA7- CA00 Wiring kit for contactors S00 RA9-AA Wiring kit for contactors S00 RA9-BB Wiring kit for contactors S0 RA9-AA Wiring kit for contactors S0 RA9-BB AS-Interface Direct-on-line start ) ) Reversing start ) ) ) ) ) ) Star-delta start Function module RA7- AA00 Function module RA7- BA00 Function module RA7- CA00 Wiring kit for contactors S00 RA9-AA Wiring kit for contactors S00 RA9-BB Wiring kit for contactors S0 RA9-AA Wiring kit for contactors S0 RA9-BB Screw connection: connection: Screw connection: connection: Screw connection: connection: The above shown contactor assemblies can be combined with motor starter protector, overload and current monitoring relay (see the descriptions on previous pages) ) The wiring modules for control circuit are not required when using function modules with communications interface ) The contactor upon which the basic module is fitted must be selected as a communication contactor (see page ) ) Consisting of basic module and interface module ) Consisting of basic module and interface modules 9

Communications Compact Starter IO-Link Setting range of thermal overload release RA6 direct-on-line starter RA6 reversing starter Coordination type / CPS ) Coordination type / CPS ) Accessories for Compact Starter with IO-Link and RA7 function module Ribbon cable, -pin, cm, for small gaps between two contactors RA7-0EE0 M [A] AC/DC V AC/DC V 0. 0. RA600- AB RA600- AB 0.. RA600- BB RA600- BB RA600- CB RA600- CB RA600- DB RA600- DB RA600- EB RA600- EB Module connector, -pin, cm, for wider gaps between two contactors Control module, (incl. enabling chip and blanking cover) Connecting cable for control module RA7-0EE0 RA69-0A RA69-0A AS-Interface + = Setting range of thermal overload release [A] RA6 direct-on-line starter Coordination type / CPS ) AC/DC V RA6 reversing starter Coordination type / CPS ) AC/DC V Accessories for AS-Interface AS-i addressing unit AS-Interface add-on modules for RA6 Compact Starter ( V DC ) RK90-AB0 M 0. 0. RA60- AB RA60- AB 0.. RA60- BB RA60- BB RA60- CB RA60- CB RA60- DB RA60- DB RA60- EB RA60- EB Without additional inputs/outputs With two local inputs With two unassigned external inputs With one unassigned external input and output each With two unassigned external outputs For on-site control RA6970-A RA6970-B RA6970-C RA6970-D RA6970-E RA6970-F ) CPS: Control and protective switching device, IEC/EN 6097-6- Screw connection: connection: 0 Size S00 Size S0 Size S Size S Size S6, S0, S Fuseless Load Feeders Communication Feeder Combinations Infeed System Accessories

RA6 Infeed system (Compact Starter) Type Terminal type -phase feeders Screw feeding / mm² left with fixed-mounted triple expansion module Screw connection RA6-AB Screw feeding / mm² left with fixed-mounted triple expansion module connection RA6-AC Screw feeding 0 70 mm² left with fixed-mounted triple expansion module Screw connection RA6-AB 9 Screw feeding 0 70 mm² left with fixed-mounted triple expansion module feeding / mm² left or right up to 6 A connection RA6-AC RA60-AC Expansion module Dual expansion module with slots Screw connection RA6-0AB 7 Triple expansion module with slots Screw connection RA6-0AB NSB0_07 Dual expansion module with slots connection RA6-0AC Triple expansion module with slots connection RA6-0AC Expansion plug 0 6 Expansion plug between expansion modules (already included in the delivery scope of the expansion modules) PE supply 6 PE tap PE supply / mm² Screw connection RA660-6AB PE supply / mm² connection RA660-AC PE tap 6/0 mm² Screw connection RA670-AB Items 6 and 9 already included in the scope of delivery PE tap 6/0 mm² connection RA670-AC 7 PE expansion plug RA690-0EA Link wedge (already included in the scope of supply of and ) 9 Cover cap of the energy bus (already included in the scope of supply of ) Adapter for SIRIUS RV motor starter protector 0 Adapter mm for RV for motor starter protector with screw connection Expansion plug for SIRIUS RV9 Infeed system Terminal block to integrate -, - or -pole components connection RA690-0BA RA690-AA RV97-D

RV9 Infeed system (motor starter protector and load feeder) Type Version Size for RV0, RV motor starter protectors For motor starter protectors S00, S0 RV97-A For motor starter protectors S00, S0 RV97-E For motor starter protectors S00, S0 RV97-A For motor starter protectors S00, S0 RV97-B S00 RV97-CA00 pc. S00 connection 0 pcs. S00 RV97-AA00 7 9 6 -phase busbars with infeed on the left incl. end cover RV97-6A with infeed on the right incl. end cover RV97-6A For system expansion incl. expansion plug RV97-BA00 For system expansion incl. expansion plug RV97-BA00 Connector For contacting the motor starter protectors Screw connection Screw connection NSB0_007 6 7 Accessories 9 Expansion plug End cover 0 pcs. S00 pc. S0 0 pcs. S0 pc. S0 connection 0 pcs. S0 Contactor base for building up direct-on-line or reversing starters Terminal block to integrate -, - or -pole components DIN rail, mm, to integrate other devices into the system, such as SY motor starter protectors Wider expansion plug Spare parts pc. pc. S00, S0 RV97-C RV97-A RV97-AA00 RV97-A RV97-AA00 RV97-A RV97-7AA00 RV97-D RV97-7B RV97-E RV97-BA00 RV97-6A

-phase comb busbars / US busbar adapters for supply Type Size For supplying several RV motor starter protectors (screw-connected) mounted side by side on DIN rails, safe to touch For motor starter protectors For motor starter protectors For motor starter protectors 6 Modular spacing mm Modular spacing 6 mm S00, S0 RV9-AB RV9-AB RV9-AB S00, S0 RV9-CB RV9-CB RV9-CB S00, S0 -phase supply terminals Modular spacing mm S00, S0 For motor starter protectors 6 -phase comb busbars Connection from the top S00, S0 Connection from the bottom S00, S0 RV9-BB RV9-DB RV9-B -phase supply terminals to build up type E starters Connection from the top S00, S0 RV9-EB Cover caps for connecting lugs Touch protection for unassigned slots S00, S0 RV9-6AB Accessories Size Version (Length) S00 00 mm US-DS0 S0 60 mm US-NT0 S00, S0 60 mm US-DT S0 60 mm US-NT 00 mm US-AS0 60 mm US0- AT0 00 mm US99-BJ0 Busbar adapter for 60 mm system For load feeders Rated current 6 A for screw connection For load feeders Rated current A for screw connection For load feeders Rated current 6 A for spring-loaded connection For load feeders Rated current A for spring-loaded connection RV9-DB RV9-AB Type RV9-BB Accessories Support for side mounting on busbar adapter, mm wide Support for side mounting on busbar adapter, mm wide Side module to widen the busbar adapter, 9 mm wide Spacer Fixes the load feeder on the adapter Vibration/shock kit To compensate strain from higher vibration and shock US99-BA0 US99-CA0 Size S00 Size S0 Size S Size S Size S6, S0, S Fuseless Load Feeders Communication Feeder Combinations Infeed System Accessories

Accessories for RV motor starter protector (S00, S0) Type Version Screw connection Accessories for RV motor starter protector, size S00, S0 Auxiliary and signaling contacts connection Ring cable lug connection 6 6 Front-mounted auxiliary block CO RV90-D NO + NC RV90-E RV90-E RV90-E NO RV90-F RV90-F Auxiliary switch suited for electronic components CO RV90-G Side-mounted auxiliary block with contacts NO + NC RV90-A RV90-A RV90-A NO RV90-B RV90-B NC RV90-C RV90-C Side-mounted auxiliary block with contacts NO +NC RV90-J Signaling switch RV9-M RV9-M RV9-M Auxiliary release Shunt trip ) AC/DC 0 70 V RV90-DB0 RV90-DB0 AC 0 0 V RV90-DP0 RV90-DP0 Undervoltage release ) AC 0 V RV90-AP0 RV90-AP0 RV90-AP0 Undervoltage release with leading auxiliary contacts Disconnector module and terminal blocks AC 00 V RV90-AV0 RV90-AV0 RV90-AV0 AC 0 V RV9-CP0 RV9-CP0 AC 00 V RV9-CV0 RV9-CV0 AC V RV9-CV RV9-CV RV9-CV Disconnector module RV9-A Terminal block type E for higher creepage distances and air clearances RV9-H Phase barriers for higher creepage distances and air clearances RV9-K Type Version ) Rotary door-coupling operating mechanisms Rotary door-coupling operating mechanism (black) with Extension shaft 0 mm RV96-0B Extension shaft 0 mm RV96-0K EMERGENCY STOP rotary door-coupling operating mechanism (red/yellow) with Extension shaft 0 mm RV96-0C Extension shaft 0 mm RV96-0L Molded-plastic housing For motor starter protector (+ Side-mounted auxiliary block) mm RV9-CA00 For motor starter protector (+ Side-mounted auxiliary block + auxiliary release) 7 mm RV9-DA00 ) More versions on request ) Only available as screw-connected versions Molded-plastic housing with EMERGENCY STOP rotary door-coupling operating mechanism For motor starter protector (+ Side-mounted auxiliary block) mm RV9-FA00 For motor starter protector (+ Side-mounted auxiliary block + auxiliary release) 7 mm RV9-GA00

Accessories for RV circuit breakers (S, S) Type Version For size Accessories for RV circuit breakers (S, S) 7 Auxiliary and signaling switches Transverse auxiliary switch W S, S RV90-D NO + NC S, S RV90-E NO S, S RV90-F Transverse auxiliary switch with contacts NO + NC S, S RV90-A NO S, S RV90-B 6 Transverse auxiliary switch with contacts NC S, S RV90-C NO + NC S, S RV90-J Shunt release AC 0 V S, S RV90-DP0 Undervoltage release AC 0 V S, S RV90-AP0 6 7 Undervoltage release with leading auxiliary switches AC 0 V S, S RV9-CP0 Signal switch S, S RV9-M NSB0_0 Isolator module S RV9-A Size S00 Size S0 Size S Size S Size S6, S0, S Fuseless Load Feeders Communication Feeder Combinations Infeed System Accessories

Accessories for RT0 contactors (S00) 6 6 7 0 0 9 6 7 Front mounting auxiliary contacts for Version Screw connection Springloaded connection RT contactors Standard see tabular overview on page ff. -pole auxiliary contact block, cable entry from the top -pole auxiliary contact block, cable entry from the top -pole auxiliary contact block, cable entry from the bottom -pole auxiliary contact block, cable entry from the bottom -pole auxiliary contact blocks ), (in compliance with DIN EN 0 0 and DIN EN 0 00) Auxiliary contact blocks suitable for electronic components (-pole) (in compliance with DIN EN 0 00) Communication see page 6 NO RH9-AA0 NC RH9-AA0 NO + NC RH9-LA NO RH9-LA0 NO RH9-BA0 NC RH9-BA0 NO + NC RH9-MA NO RH9-MA0 Ring cable lug connection NC RH9-HA0 RH9-HA0 RH9-HA0 NC RH9-HA0 RH9-HA0 RH9-HA0 NO + NC RH9-HA RH9-HA RH9-HA NO + NC RH9-HA RH9-HA RH9-HA NO RH9-HA0 RH9-HA0 RH9-HA0 NO RH9-HA0 RH9-HA0 RH9-HA0 NO + NC RH9-NF RH9-NF NO RH9-NF0 RH9-NF0 Ö RH9-NF0 RH9-NF0 see page 7 (Function modules for mounting on contactors and for interfacing the control system) 9 Size-specific accessories for RT0 contactors (S00) Auxiliary contact blocks for side mounting (in compliance with DIN EN 0 0 and DIN EN 0 00) NO RH9-DA0 RH9-DA0 NO + NC RH9-DA RH9-DA RH9-DA NC RH9-DA0 RH9-DA0 ) More auxiliary contact blocks on request ) For further surge suppressors, refer to the Industry Mall or the IC 0 catalog 0 Auxiliary contact block suited for electronic components for side mounting (on the right) (in compliance with DIN EN 0 0 and DIN EN 0 00) Soldering pin adapter for contactors with -pole auxiliary contact block Soldering pin adapter for contactors Surge suppressor, e.g. varistor (0 V AC) ) NO + NC RH9-DE For contactors (pack) For contactors (pack) RT96-KA RT96-KA without LED AC 7 0 V RT96-BD00 RT96-BD00 RT96-BD00 with LED AC 7 0 V RT96-JL00 RT96-JL00 RT96-JL00 Terminal module for contactor with screw connection -phase supply terminal Adapter Plug AC-/00 V: 0 A RT96-RD0 Conductor cross section: 6 mm RT900-RE0 RA9-K

Accessories for RT0 contactors (S00) 6 7 9 0 6 7 Front mounting auxiliary contacts for Comment Version Screw connection connection RT contactors Standard see tabular overview on page ff. Communication see page 6 -pole auxiliary contact block, cable entry from the top -pole auxiliary contact block, cable entry from the top -pole auxiliary contact block, cable entry from the bottom -pole auxiliary contact block, cable entry from the bottom -pole auxiliary contact block ), (in compliance with DIN EN 0 0 and DIN EN 0 00) Auxiliary contact blocks suitable for electronic components (-pole) (in compliance with DIN EN 0 00) Ring cable lug connection NO RH9-AA0 RH9-AA0 NO + NC RH9-LA NO RH9-LA0 NO RH9-BA0 NC RH9-BA0 NO + NC RH9-MA NO RH9-MA0 NC RH9-HA0 RH9-HA0 RH9-HA0 NC RH9-HA0 RH9-HA0 RH9-HA0 NO + NC RH9-HA RH9-HA RH9-HA NO + NC RH9-HA RH9-HA RH9-HA NO RH9-HA0 RH9-HA0 RH9-HA0 NO RH9-HA0 RH9-HA0 RH9-HA0 NO + NC RH9-NF RH9-NF NO RH9-NF0 RH9-NF0 NC RH9-NF0 RH9-NF0 see page 7 (Function modules for mounting on contactors and for interfacing the controller) 9 0 Size-specific accessories for RT contactors Auxiliary contact blocks acc. to DIN EN NO RH9-DA0 RH9-DA0 for side mounting (on the right) 0 00 NO + NC RH9-DA RH9-DA RH9-DA (in compliance NC RH9-DA0 RH9-DA0 with DIN EN 0 0 and DIN EN 0 00) Auxiliary contact block for side acc. to NO + NC RH9-DE mounting (on the right), suitable for electronic components DIN EN 0 00 Overvoltage limiter, e.g. varistor (0 V AC) without LED AC 7 0 V RT96-BD00 RT96-BD00 RT96-BD00 with LED AC 7 0 V RT96-JL00 RT96-JL00 RT96-JL00 Terminal module for contactor Adapter AC-/00 V: RT96-RD0 with screw connection Plug A RT900-RE0 Pneumatic delay block (in compliance with DIN EN 0 00) NO + NC 0. 0 s ON delay RT96-PA0 60 s RT96-PA 0. 0 s OFF delay RT96-PR0 60 s RT96-PR ) More auxiliary contact blocks on request ) For further surge suppressors, refer to the Industry Mall or the IC 0 catalog Coil terminal module Connection from the top Connection from the bottom Diagonal connection RT96-RA RT96-RA RT96-RB RT96-RB RT96-RC RT96-RC Size S00 Size S0 Size S Size S Size S6, S0, S Fuseless Load Feeders Communication Feeder Combinations Infeed System Accessories 7

Accessories for RT contactors (S to S) 6 0 7 6 7 0 9 6 7 9 0 6 7 Contactor, size S (example) control supply voltage For sizes S to S Solid-state time-delay block, ON delay Solid-state time-delay block, OFF delay Auxiliary switch block, solid-state time-delay ON delay OFF delay -pole auxiliary switch block, cable entry from above -pole auxiliary switch block, cable entry from below -pole auxiliary switch block, (terminal designations acc. to DIN EN 0 0 or DIN EN 0 00) Link for paralleling (star jumper), -pole, without terminal Version For size 7. kw/00 V RT0 -AP00 0 V 0 Hz 0. 0 s RT9 6-CH 0. 0 s RT9 6-DH 0. 0 s RT9 6-ED 0. 0 s RT9 6-FL NO + NC RH9 -LA NO + NC RH9 -MA NO + NC RH9 -HA S S RT9 6-BA RT9 6-BA Link for paralleling, -pole, with terminal S RT9 6-BB S RT9 6-BB -pole auxiliary switch block, can be laterally NO + NC S S RH9 -DA mounted (left or right), (terminal designations acc. to DIN EN 0 0 or DIN EN 0 00) -pole auxiliary switch block NO S S RH9 -CA0 (up to can be snapped on) NC S S RH9 -CA0 Mechanical interlock, can be laterally mounted S S RA9 -B Mechanical interlock, can be mounted S S RA9 -A at the front Wiring connectors at the top and bottom S RA9 -A (reversing operation) S RA9 -A S RA9 -A Surge suppressor (varistor, RC coupling, S S RT9 6-BD00 diode combination), can be mounted at the top or bottom Interface for mounting directly onto the S S RT9 6-AB contactor coil LED module to indicate contactor operation S S RT9 6-QT00 Mechanical latching AC/DC S RT9 6-AB AC/DC 0 S RT9 6-AF AC/DC 0 S RT9 6-AP ) For further surge suppressors, refer to the Industry Mall or the IC 0 catalog

Accessories for RT contactors (S6 to S) 6 6 Schüt e Baugrössen S6 bis S it Zubehör uftschüt 0 und Baugrössen S6 S0 und S ilfsschalterbl c ele tr nisch er öger t ans rech der rüc fall er ögert der Stern reiec un ti n liger ilfsschalterbl c nschlussbe eichnungen nach 0 0 der 0 00 liger ilfsschalterbl c eitungseinführung n ben 6 liger ilfsschalterbl c eitungseinführ n unten liger ilfsschalterb l c a aufschna bar liger ilfsschalterbl c seitlich rechts der lin s anbaubar nschlussbe eichnungen nach 0 0 der 0 00 gleich für S0 bis S bers annungsbegren er Glied ben an inschubs ule anstec bar 0 echanische erriegelung seitlich anbaubar erdrahtungsbausteine ben und unten e ersierbetrieb Operating mechanism types 7 0 arallelschalt erbindung Stern un tbrüc e lig it urchgangsl ch unterschiedlich r fü Baugrössen S6 und S0 S nschlussabdec ung für abelschuh und Schienenanschluss unterschiedlich für Baugrössen S6 und S0 S le enabdec ung für ah en le e unterschiedlich für Baugrössen S6 und S0 S ah en le enbl c unterschiedlich für Baugrössen S6 und S0 S Gleiches Zubehör für Baugrössen S0 bis S Gleiches Zubehör für Baugrössen S6 bis S Zubehör unterschiedlich je nach Baugrösse 9 0 RT0 and RT air contactors, Sizes S6, S0 and S RT vacuum contactor, Sizes S0 and S Withdrawable coils for contactors with conventional operating mechanism RT -.A.. Withdrawable coils for contactors with electronic operating mechanism RT -.N.. Withdrawable coils and laterally mounted module (can be plugged in) for contactors with electronic operating mechanism and remaining lifetime signal RT -.P.. and RT -.Q Type Version -pole auxiliary switch block, can be laterally mounted nd block (left/right), DIN EN 0 0 NO + NC RH9-JA nd block (left/right), DIN EN 0 00 NO + NC RH9-KA -pole auxiliary switch block, can be mounted at the front Size S00 Size S0 Size S Size S Size S6, S0, S Fuseless Load Feeders Communication Feeder Combinations Infeed System NO RH9-KA0 with classification No., DIN EN 0 0 NO + NC RH9-XA-0MA0 with classification No., DIN EN 0 0 NO + NC RH9-HA -pole auxiliary switch block, can be mounted at the front NO RH9-CA0 NC RH9-CA0 -pole auxiliary switch block, can be mounted at the front, NO + NC RH9-LA cable entry from above, DIN EN 0 00 -pole auxiliary switch block, can be mounted at the front, NO + NC RH9-MA cable entry from below, DIN EN 0 00 6 Auxiliary switch block, solid-state time-delay NO + NC ON delay, 00 0 V AC 0... 0 s RH96-ED OFF delay, 00 0 V AC 0.... 0 s RH96-FL 7 RC element, 7 0 V AC ) RT96-CD00 Wiring connectors top and bottom for S6 for S0 for S RA9-M RA96-A RA97-A 9 Connection cover for box terminals for S6 RT96-EA for S0/S RT966-EA 0 Terminal cover for cable lug and busbar connection for S6 RT96-EA for S0/S RT966-EA Mechanical interlock RA9-A Size -phasemotor 00 V/AC- Contactor without coil Withdrawable coil for operating mechanism conventional control supply voltage AC/DC 0...0 V electronic AC/DC 00...77 V kw S6 RT0-LA06 RT9-AP RT9-NP 7 RT0-6LA06 90 RT06-6LA06 S0 0 RT06-6LA06 RT96-AP RT96-NP RT06-6LA06 60 RT066-6LA06 S 00 RT07-6LA06 RT97-AP RT97-NP 0 RT076-6LA06 ) For further surge suppressors, refer to the Industry Mall or the IC 0 catalog Accessories 9

Accessories for RU thermal overload relay, RB0/ solid-state overload relay, RR analog current monitoring relay and RR digital current monitoring relay (S00, S0) 0 Version For size Can be combined with the following overload and current monitoring relays Relay base for stand-alone mounting For mounting the overload relays separately S00 RU96-A 0 For screw and snap-on mounting on TH DIN rail S0 RU96-A 0 Mechanical RESET consisting of: Reset slide, holder and funnel S00, S0 RU900-A Reset slide, holder and funnel S00, S0 RB90-0A RU RB RR RR Push button with elongated stroke ( mm), IP6, Ø mm Extension tappet to even out the spacing between a push button and the reset button of the relay S00, S0 SB000-0EA S00, S0 SX Cable release with holder for RESET for bores Ø 6. mm in the control panel Length 00 mm S00, S0 RU900-B Length 00 mm S00, S0 RB90-0B Length 600 mm S00, S0 RU900-C Length 600 mm S00, S0 RB90-0C Sealable cover for RB0/, transparent For covering the setting components S00, S0 RV90-0P For covering the setting components S00, S0 RB9-0 For covering the setting components S00, S0 RR90 Modules for remote reset... 0 V AC/DC S00, S0 RU900-AB7 0... 7 V AC/DC S00, S0 RU900-AF7 0... 0 V AC/DC S00, S0 RU900-AM7 Screw connection: connection: A C

Accessories for RU thermal overload relay and RB0/ solid-state overload relay Accessories for motor starters Version For size Terminal support for stand-alone assembly for RU for separately mounting the overload relays, screw-type and snap-on fastening on TH DIN rails, size S also for TH 7 DIN rails Mechanical RESET for RU and RB0/ comprising: S S RU96-AA0 RU96-AA0 Resetting plunger, holder and former S S0/S RU900-A -phase motor 00 V/AC- [kw] Enclosure for direct starters Size Moulded-plastic enclosure for wall mounting IP6 degree of protection with actuator elements S RE9-CB Push button with extended stroke ( mm), IP6, Ø mm Extension plunger for compensation of the distance between a push button and the relay s release button S S0/S S S0/S SB000-0EA SX Components required Contactor RT0 Qty. Cable release with holder for RESET RU and RB0/ for holes 6. mm diameter in the panel; max. panel thickness mm Thermal or solid-state overload relay RU 6 resp. RB0 6 Length 00 mm S S0/S RU900-B Lateral auxiliary switch NO/NC RH0-DA Length 600 mm S S0/S RU900-C Sealable cover, transparent for RB0/ to cover the setting elements S S0/S RB9-0 Terminal covers for RU and RB0/ Cover for cable lug and busbar connection S RT96-EA S6 RT96-EA S0/S RT966-EA Cover for box terminals S RT96-EA S RT96-EA S6 RT96-EA S0/S RT966-EA Cover for the screw connection between the contactor and overload relay without box terminals (x is required for each combination) S6 S0/S RT96-EA RT966-EA Box terminal block for round and ribbon cables up to 70 mm S6 T9-G up to 0 mm S6 T96-G up to 0 mm S0/S T966-G Size S00 Size S0 Size S Size S Size S6, S0, S Fuseless Load Feeders Communication Feeder Combinations Infeed System Accessories

Support As competent and reliable partner, we not only offer tried-and-tested products and systems, but also comprehensive support from initial information to planning, configuration and ordering, down to commissioning, ongoing operation and technical service: Product information Comprehensive information on Industrial Controls Amongst others, rapid and targeted provision of information on: SIRIUS Industrial Controls Ensure your success with our trendsetting system solutions! www.siemens.com/ sirius Access to all important and up-to-date information: From the website to the newsletter, down to the download of complete brochures Ordering and information platform for all products and systems Efficient tools for increased productivity, e.g. CAx DVD for your configuration process Service & Support Portal for comprehensive technical information on configuration and system documentation Newsletter: always up to date Constantly updated information on the subjects of Industrial Controls www.siemens.com/ industrial-controls/ newsletter We thus provide you with a comfortable basis for optimizing your processes. In short: Support for improved efficiency! Information Planning Configuration Ordering Commissioning Operation Service Product information Easy download of catalogs and information material Our Information and Download Center offers all current Catalogs Customer magazines Brochures for download Product selection www.siemens.com/ industrial-controls/ infomaterial Promotion website Newsletter portal Information and Download Center Industry Mall Software for Industrial Controls Service & Support Portal CAx DVD Image database Product information Product selection Product & system engineering Product documentation Product selection Industry Mall: platform for e-business and product information Benefit from /7 access to our comprehensive information and ordering platform for the complete Industrial Controls portfolio, including: Selection tools, product and system configurators Availability check Order tracking www.siemens.com/ industrial-controls/ mall www.siemens.com/ industrial-controls/ configurators SITRAIN Portal Product training Technical Assistance Product hotline

Product & system engineering Product training Software for Industrial Controls: easy, fast and safe Our software supports you throughout all project phases from planning to parametrization, down to operation. Parametrization and Configuration with SIRIUS Industrial Controls Planning and Dimensioning of electrical power distribution systems with SIMARIS www.siemens.com/ industrial-controls/ mall www.siemens.com/ simaris Easy download of product image material Our image database contains all current Product images -D dimension drawings, isometric illustrations and -D models Internal circuit diagrams Symbols in diverse versions for free download. www.siemens.com/ industrial-controls/ picdb Product documentation Online support: full-range technical product information /7 access to comprehensive technical information on our products and systems to support you from the planning to the configuration down to the operation phase. Product data sheets, manuals/ operating instructions Certificates, characteristic curves, downloads FAQs Technical Product Data for CAx Applications: immediate availability of configuration-relevant CAx data types for your CAD/CAE system This DVD provides you with a comprehensive pool of configurationrelevant CAx data types. Commercial and technical product master data -D dimension drawings, isometric illustrations and -D models Product data sheets Tender specifications www.siemens.com/ industrial-controls/ support CAx Online- Generator: www.siemens.com/ industrial-controls/ support CAx-DVD: E6060- D000-A07-A7-600 (Industry Mall) Product hot line Training: knowledge expansion Our training offer both comprises an overview as well as detailed competencies regarding selected products and systems. Amongst others, you can expand your product and system know-how of SIRIUS. Technical Assistance: competent Industrial Controls expert consulting We support you with all technical enquiries regarding our products and systems both before and after delivery. Product selection Old/new conversions, competitor conversions Special versions, special requirements Commissioning, operation Tip: the Service & Support Portal, including the FAQ database, can be called up via www.siemens. com/industrial-controls/technicalassistance. You can also directly submit your support request to a technical consultant. www.siemens.com/ sitrain Or contact us personally via the information hotline: via telephone: +9 (9) 9 77 via fax: +9 (9) 9 776 via e-mail: info@sitrain.com www.siemens.com/ industrial-controls/ technical-assistance Personally from Mo. through Fr..00 am to.00 pm (CET) via telephone: +9 9 9 900 via e-mail: technical-assistance@ siemens.com via fax: +9 9 9 907

Siemens AG Industry Sector Control Components and Systems Engineering P. O. Box 907 FÜRTH GERMANY www.siemens.com/sirius Subject to change without prior notice 0/0 : E000-A0-P0-V6-7600 Dispo 760 SRXX...0 WS 090.0 Printed in Germany Siemens AG 00 The information provided in this brochure contains me re ly general descriptions or characteristics of per for m ance which in ac tual case of use do not always ap ply as described or which may change as a result of fur ther de ve lopment of the pro ducts. An obligation to provide the respective characteristics shall only exist if ex pressly agreed in the terms of contract. All product designations may be trademarks or product na mes of Siemens AG or supplier companies whose use by third parties for their own purposes could violate the rights of the owners.