Model UT713 OPERATING MANUAL



Similar documents
Model UT33B/C/D: OPERATING MANUAL Table of Contents (1)

Model UT58A/B/C: OPERATING MANUAL

Model UT33A: OPERATING MANUAL Table of Contents (1)

Model UT201/202: OPERATING MANUAL. Table of Contents

UT202A Operating Manual. Contents

Model UT60A: OPERATING MANUAL. Table of Contents. Page

Model UT71A/B OPERATING MANUAL

Model UT61A/61B/61C/61D/61E: OPERATING MANUAL. Table of Contents

The table below lists the symbols used on the Clamp and/or in this manual. Important Information. See manual.

Table of Contents. Page

User Guide. 4 wire Earth Resistance Tester Model GRT300

10 Multimeter. Users Manual

Manual Ranging MultiMeter

i410/i1010 AC/DC Current Clamp

EPM3. Phase Sequence and Motor Rotation Tester. Users Manual

Intelligent Digital Multimeters

HVAC Clamp Meter. Users Manual

Multifunction Process Calibrator

AutoRanging Digital MultiMeter

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODELS:

RS DIGITAL THERMOMETER

User's Guide. True RMS Industrial Multimeter

Instruction Manual. 2in1 LAN Tester & Multimeter. Model: LA-1011

2013 VTech Printed in China US

323/324/325. Calibration Manual. Clamp Meter

User s manual FLIR VP50/VP52 Non-contact AC voltage detector

How To Use A Cdm250 Digital Multimeter

RIGOL. Quick Guide. DS1000CA Series Oscilloscope. Aug RIGOL Technologies, Inc.

Programmable Room Thermostat 7 Day (5-2 Day) Models: / Power Supply: Battery / Mains

Portable Air Conditioner

VOLTAGE/CURRENT CALIBRATOR ISO-TECH ILC-421

Drayton Digistat +2RF/+3RF

Multi Tube Rotator. Model No. 4632Q CE CECN /05/11

Ref. Nr LCP-288 LED COLOR PANEL 288X LED 5MM MANUAL

1587/1577. Insulation Multimeters. Technical Data. Two powerful tools in one.

ADM1TE 5/30A DIN rail single phase two wire energy meter

Temperature Humidity Meter

How To Use A Meter

USB TC-08. Temperature Logger. User's Guide. usbtc08.en r7 Copyright Pico Technology Limited. All rights reserved.

Ground Resistance Clamp On Tester

DRM75A 230V 20/100A DIN rail single phase two wire energy meter

USER MANUAL WARNING! CONTENTS MODEL 1 SPECIFICATIONS READ ALL INSTRUCTIONS BEFORE PROCEEDING. Non-Programmable Single Stage Heat/Cool Thermostat

Technical Update TAA.TU Rev. 1

EVC40 EMERGENCY VOICE COMMUNICATION SYSTEM

SATEX SA Manual. Weegtechniek holland b.v. PRECISION BALANCE. Patroonsweg DA Zeewolde HOLLAND

User Guide. Model Insulation Tester / Megohmmeter

162 CB CABLE TRACER. Filter Probe & Tone Generator INSTRUCTION MANUAL

INSTRUCTION MANUAL PLEASE READ ALL THE INSTRUCTIONS COMPLETELY BEFORE USE AND SAVE THIS MANUAL FOR FUTURE REFERENCE

aseries A13B Mini Bullet Camera User Manual

Ingenico. User Guide 5100M. Secure transaction and payment solutions

7 FUNCTION DIGITAL MULTIMETER

Thermistor Thermometer MODEL NO

Hygro-Thermometer + InfraRed Thermometer Model RH101

Business Audio System: Music & Messaging MP3 Player. by Grace Digital Audio. User Guide. Model No. GDI-USBM10

Getting started with

Achat 115MA full-range speaker. user manual

MCR1900 Media Converter 19-Slot Chassis

MILLENIUM INSTALLATION MANUAL NTR 735 A. Simple Automation Control Module (MAS)

DC POWER SUPPLY ALIMENTATION C.C.

GSM Door Phone System

Optical Power Meter. Specification & User Manual

PowerFlex 700S and 700H Frame 12 DC Bus Connector Kit

OPERATION MANUAL. Pen type, separate electrode SOIL PH METER Model : PH-220S

TMS TANK MANAGEMENT SYSTEM

Art.S001-S002 SOLAR MODULE WITH DELIVERY AND RETURN CONNECTIONS

Split Type Room Air Conditioner. KSWM units

Ground Resistance Clamp-On Tester

Current Monitoring Kit QUICK START GUIDE

MOUNTING AND OPERATING INSTRUCTIONS

Seven function digital multimeter

COMPLETE MANUAL. Version: Optic. September 2015 (English), version 1.0. EnergyOT Optic Developed and Manufactured by Genoa Spark, lda Made in Portugal

Current Monitoring Kit

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

THERMAL ANEMOMETRY ELECTRONICS, SOFTWARE AND ACCESSORIES

PowerFlex 700H and 700S AC Drives Frame 11 Main Fan Capacitor Replacement Kit

K Standard Grade Ni-Cr vs Ni-Al (Chromel vs Alumel)

CONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE. General purpose single phase thyristors and solid state relays Product data.

Product and Application Description

Pre-installation Manual. CONCEPT Processor 305 DW / 405 DW / 505 DW 505 DW XP

COLOR VIDEO DOOR PHONE CDV-71BE/D

How To Use The Visifault Visual Fault Locator

Microwave Meter. Instruction Manual

CELO5. User & Installation Manual.

Auto-ranging Digital Multimeter INSTRUCTION MANUAL

1. SAFETY INFORMATION

12. Inspection and Maintenance

MODEL 2202IQ (1991-MSRP $549.00)

H/L = Power supply. FN = Nominal Frequency. RN = Rated value of output burden. UN = Nominal input voltage. IN = Nominal input current.

USER MANUAL Stand Alone Power Supply PSQ 2909 / PSQ 3909 / PSQ 4909 PSQ 2920 / PSQ 3920 / PSQ 4920

User Manual. Humidity-Temperature Chart Recorder. Model RH520

Thermocouple Thermometer Models

DALI RC BASIC SO. Control unit Operating instructions

RS Stock No Instruction Manual RS-1340 Hot Wire Anemometer

BroadBand PowerShield. User Manual

Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate

帝 聞 企 業 股 份 有 限 公 司 DEE VAN ENTERPRISE CO., LTD. SP DSL-20WA Revision: A Date: FOR AC-DC LED DRIVER MODEL NO.

PRELIMINARY MANUAL STAGE COLOR 48. Preliminary User Guide. Official version will follow soon on: TABLE OF CONTENTS

Heating Controller. Building Technologies HVAC Products

Transcription:

Model UT713 OPERATING MANUAL

TABLE OF CONTENTS TITLE PAGE Introduction Unpacking Inspection Safety Information Turning the Calibrator On Simulating a Thermocouple Measuring a Thermocouple Simulating TC or Source mv Measure TC or mv Cold Terminal Temperature Autocompensation Explanation of International Symbols Maintenance Specifications Temperature Measure and Thermocouple Simulate 3 3 4 6 6 7 8 10 12 14 15 19 19 1

TABLE OF CONTENTS TITLE PAGE Thermocouple Standards and Scales Millivolt Measure and Source General Specifications 21 21 22 2

Introduction The UNI-T Model UT713 Thermocouple Calibrator is a precise source and measurement tool for calibrating thermocouple instruments. The calibrator sources or measures mv or 8 different type of TC in units of,. But the Meter cannot uses as an output source and measurement. Unpacking Inspection Open the package case and take out the Meter, check the following items carefully to see any missing or damaged parts: Item 1 2 3 4 Description Operating Manual Test Lead Alligator Clip 9V Alkaline Battery (1604A or 6LF22) Qty 1 piece 1 pair 1 pair 1 piece 3

Safety Information This Meter complies with the standard CE EN61326. Use the Meter only as specified in this operating manual, otherwise the protection provided by the Meter may be impaired. Warning To avoid possible electric shock or personal injury: Before using the calibrator inspect the case. Do not use the calibrator if it is damaged or the case (or part of the case) is removed. Look for cracks or missing plastic. During measurement, do not contact the naked wire, connector, unused terminal or the circuit under test. Inspect the test leads for damaged insulation or exposed metal. Replace damaged test leads with identical model number or electrical specifications before using the Meter. When using the test leads, keep your fingers behind the finger guards. Never apply more than 30V between any two terminals, or between any terminal and earth ground. 4

Replace the battery as soon as the battery indicator appears. With a low battery, the Meter might produce false readings that can lead to electric shock and personal injury. The internal circuit of the calibrator shall not be altered at will to avoid damage of the calibrator and any accident Do not use or store the calibrator in an environment of high temperature, humidity, explosive, inflammable and strong magnetic field. The performance of the Meter may deteriorate after dampened Under the influence of Radiated, Radio-Frequency Electromagnetic Field phenomenon, the captioned model may malfunction and can self-recover after the test. When servicing the Meter, use only the same model number or identical electrical specifications replacement part. Constantly check the battery as it may lead when it has been using for some time, replace the battery as soon as leaking appears. A leaking battery will damage the calibrator. Take out the battery when not using for a long time. 5

Turning the Calibrator On Press to turn the calibrator on and off Output Show TC type or voltage range selected Press to toggle or Press so that OUTPUT is on the display Press TYPE to select TC type or DC mv 6 Press to turn the Meter on and off Press and to increment or decrement a digit. Press and to step up/down from 0 to 9. Hold down to scroll faster Figure 1 Press to toggle positive or negative temperature Output Terminals

Show TC type or voltage range elected Input Display the selected or Press so that INPUT is on the display Press to toggle or Press to turn the Meter on and off Input Terminals Press Type to select TC type or DC mv Figure 2 7

1. Press the pushbutton to turn the Calibrator on. 2. Press OUTPUT to display OUTPUT if the Calibrator is at input mode which displays INPUT. 3. Press to select the requested TC type or DC mv range. 4. Press or to increment or decrement a digit. 5. Press or to step up or down from 0 to 9. Hold down to scroll faster. 6. Insert the test leads to the OUPUT terminals as figure 3. 7. Connect the other end of the test leads to the TC measurement equipment or the DC mv measurement equipment. Note: When connecting the calibrator to the auto ranging DC mv measurement equipment or TC measurement equipment, it must lock the range. 8

Measurement equipment Figure 3 9

1. Press the pushbutton to turn the Calibrator on. 2. Press INPUT to display INPUT if the Calibrator is at output mode which displays OUTPUT. 3. Press to select the requested TC type or DC mv range. 4. Insert the test leads to the INPUT terminals as figure 4. 5. Connect the other end of the test leads to the TC simulate equipment or the DC mv source equipment. Note: Measuring TC must select the corresponding TC type. When measuring DC mv, the input voltage must not exceed the present range of the Calibrator. When using the TC cable with standard plug to measure temperature, it is necessary to add an adaptor. 10

Output equipment Figure 4 11

Follow the below procedure to start the cold terminal temperature auto compensation functions: 1. Press the pushbutton to turn the Calibrator on. 2. Press INPUT to display enter INPUT mode 3. Press to select J type. 4. Press and hold and together to display 0 or 1 (display 0 is cold terminal temperature auto compensation, display 1 is the remove cold terminal temperature auto compensation), release the two buttons. 5. Press and to adjust the digit to 0, press to confirm. 6. Press pushbutton to turn the Calibrator off. 7. The setting is finished. 8. At that moment At simulate TC mode: The calibrator output thermoelectric force = the corresponding thermoelectric force of the set temperature minus the corresponding thermoelectric force of the room temperature. At Measure TC mode: The Calibrator display temperature = The corresponding temperature of the Calibrator input terminal thermoelectric force plus room temperature. 12

Note: Because the temperature transducer aluminum plate is put at the back of the Calibrator, try to open the tilt stand if possible when operating the Calibrator. Don t touch the aluminum plate when operating the Calibrator to ensure the accurate of compensation temperature. If the operating temperature is changed, it is necessary to wait for around 10 minutes to stable the internal transducer before operating the Calibrator. Follow the above 1 to 7 steps to remove the cold terminal temperature auto compensation, but change the adjust digit to 1 on step 4. 13

Explanation of International Symbols The following symbols are used on the calibrator or in this operating manual. The table below explains their meaning. International Symbols Symbol Meaning Grounding Warning. Refer to the Operating Manual Deficiency of Built-In Battery Double Insulated Conforms to Standards of European Union 14

Maintenance Warning Make sure the calibrator is off and the test leads are removed from the input terminals and the circuit under test before opening the calibrator s case. For maintenance procedures not described in this sheet, contact your dealer. Do not store the Meter in an environment of high temperature, humidity and strong magnetic field. Check the battery and test leads. Replace as necessary. Review this instruction manual to make sure you are using the calibrator correctly. Periodically wipe the case with a damp cloth and detergent; do not use abrasives or solvents. 15

Periodically wipe the case with a damp cloth and detergent; do not use abrasives or solvents. When the symbol appears on the display, replace the battery with a 9V alkaline battery (1604A or 6LF22) Remove the battery from the battery door and turn the calibrator off when it is not using for a long time. Figure 5 16

Warning To avoid personal injury or damage to the calibrator, use only a 125mA 250V fuse for F1. In Input mode, the calibrator and TC are reliably connected. When the display continuisly shows OL, the fuses may be blown. 17

Replace the fuses using the following procedure: 1. Remove the test leads from the calibrator terminals and turn the calibrator off. 2. Remove the screw on the battery door, then remove the battery door and take out the battery. 3. Remove the three screws from the case bottom and turn the case over. 4. Gently remove the fuse from its mounting bracket. 5. Replace the blown fuse with a 125mA 250V fuse. 6. Fit the top and bottom covers together. 7. Reinstall the three screws. 8. Replace the battery door and reinstall the battery door screw. Figure 6 18

Specifications Specifications are based on a one year calibration cycle and apply for ambient temperature from +18 to +28 unless stated otherwise. Thermocouple Type J K T E N Temperature Ranges -200.0~1200.0-328.0~2192.0-200.0~1370.0-328.0~2498.0-200.0~400.0-328.0~752.0-200.0~950.0-328.0~1742.0-200.0~1300.0-328.0~2372.0 Display Resolution 0.1 or 0.1 Accuracy 0.04% 1.5 ( -100 ) 0.04% 2.7 ( -148 ) 0.04% 1 ( -100 ) 0.04% 1.8 ( -148 ) 19

Thermocouple Type Temperature Ranges Display Resolution Accuracy R S B -20~1750-4~3182-20~1750-4~3182 600~1800 1112~3272 1 or 1 0.04% 3 ( 100 ) 0.04% 5.4 ( 212 ) 0.04% 2 ( 100 ) 0.04% 3.6 ( 212 ) 20

Thermocouple Type J, K, T, E, N, R, S, B Standard NIST-175 Scales ITS-90 Mode Range Display Resolution Accuracy mv -10.00~110.00mV 10 V 0.04% 2 digits -110.0~1100.0mV 0.1mV 21

22 Resolution: TC: 0.1 or 0.1 (J, K, T, E, N); 1 or 1 (R, S, B). DC mv: 10 V (110mV range); 0.1mV (1100mV range) Cold Junction Error: 0.5 (-0~50 ) Maximum voltage applied between any terminal and earth ground or between any two terminals: 30V Storage temperature: -10 to 55 Operating temperature: -0 to 50 Operating altitude: 3000 meters maximum Temperature coefficient:0.005% x specified range per for temperature ranges -0 to 18 and 28 to 50. Relative humidity: 95% (0 ~ 30 ), 75% (30 ~40 ) and 45% (40 ~50 ) Vibration:Random 2g, 5Hz to 500Hz. Shock: 1 meter drop test Safety: CE EN61326 Power requirements: Single 9V alkaline battery (1604A or 6LF22) Size: 193mm x 96mm x 47mm Weight: around 0.45kg (including alkaline battery)

* END * This operating manual is subject to change without notice. 23

Copyright 2007 Uni-Trend Group Limited. All rights reserved. Manufacturer: Uni-Trend Technology (Dongguan) Limited Dong Fang Da Dao Bei Shan Dong Fang Industrial Development District Hu Men Town, Dongguan City Guang Dong Province China Postal Code: 523 925 Headquarters: Uni-Trend Group Limited Rm901, 9/F, Nanyang Plaza 57 Hung To Road Kwun Tong Kowloon, Hong Kong Tel: (852) 2950 9168 Fax: (852) 2950 9303 Email: info@uni-trend.com http://www.uni-trend.com 24