Greening Data Centers



Similar documents
NetApp Data Center Design

Free Cooling in Data Centers. John Speck, RCDD, DCDC JFC Solutions

Trends in Data Center Design ASHRAE Leads the Way to Large Energy Savings

Green Data Centre Design

Data Centre Energy Efficiency Operating for Optimisation Robert M Pe / Sept. 20, 2012 National Energy Efficiency Conference Singapore

Legacy Data Centres Upgrading the cooling capabilities What are the options?

FEAR Model - Review Cell Module Block

DATA CENTER COOLING INNOVATIVE COOLING TECHNOLOGIES FOR YOUR DATA CENTER

How Does Your Data Center Measure Up? Energy Efficiency Metrics and Benchmarks for Data Center Infrastructure Systems

Dealing with Thermal Issues in Data Center Universal Aisle Containment

Specialty Environment Design Mission Critical Facilities

Energy Efficiency in New and Existing Data Centers-Where the Opportunities May Lie

Maximize energy savings Increase life of cooling equipment More reliable for extreme cold weather conditions There are disadvantages

How To Test A Theory Of Power Supply

Top 5 Trends in Data Center Energy Efficiency

Case Study: Innovative Energy Efficiency Approaches in NOAA s Environmental Security Computing Center in Fairmont, West Virginia

Data Center Facility Basics

Reducing Data Center Energy Consumption

University of St Andrews. Energy Efficient Data Centre Cooling

Heat Recovery from Data Centres Conference Designing Energy Efficient Data Centres

Self-benchmarking Guide for Data Center Infrastructure: Metrics, Benchmarks, Actions Sponsored by:

Analysis of data centre cooling energy efficiency

Enabling an agile Data Centre in a (Fr)agile market

Control of Computer Room Air Handlers Using Wireless Sensors. Energy Efficient Data Center Demonstration Project

Reducing Data Center Loads for a Large-Scale, Net Zero Office Building

Optimum Climate Control For Datacenter - Case Study. T. Prabu March 17 th 2009

National Grid Your Partner in Energy Solutions

AIA Provider: Colorado Green Building Guild Provider Number: Speaker: Geoff Overland

ICT and the Green Data Centre

GREEN DATA CENTER DESIGN

Datacenter Efficiency Program

DataCenter 2020: first results for energy-optimization at existing data centers

Managing Data Centre Heat Issues

CURBING THE COST OF DATA CENTER COOLING. Charles B. Kensky, PE, LEED AP BD+C, CEA Executive Vice President Bala Consulting Engineers

CRITICAL COOLING FOR DATA CENTERS

HPC TCO: Cooling and Computer Room Efficiency

Engineers Ireland Cost of Data Centre Operation/Ownership. 14 th March, 2013 Robert Bath Digital Realty

Energy Efficiency Opportunities in Federal High Performance Computing Data Centers

Data Center Planning. PUE Overview

Cooling Small Server Rooms Can Be. - Jim Magallanes Computer Room Uptime: Uptime Racks:

World s Greenest High Performance Data Center

Guideline for Water and Energy Considerations During Federal Data Center Consolidations

Re Engineering to a "Green" Data Center, with Measurable ROI

DataCenter Data Center Management and Efficiency at Its Best. OpenFlow/SDN in Data Centers for Energy Conservation.

Agenda. Part I: Introduction to OptimumHVAC. Part II: Initial Energy Savings Analysis for MCO Main Terminal. Part III: Case Studies & Conclusion

AIRAH Presentation April 30 th 2014

Minimising Data Centre Total Cost of Ownership Through Energy Efficiency Analysis

Data Centers: Definitions, Concepts and Concerns

Data Center 2020: Delivering high density in the Data Center; efficiently and reliably

Cooling Capacity Factor (CCF) Reveals Stranded Capacity and Data Center Cost Savings

Data Center Design Guide featuring Water-Side Economizer Solutions. with Dynamic Economizer Cooling

Cooling Capacity Factor (CCF) Reveals Stranded Capacity and Data Center Cost Savings

Greening Commercial Data Centres

Measuring Power in your Data Center: The Roadmap to your PUE and Carbon Footprint

European Code of Conduct for Data Centre. Presentation of the Awards 2014

Guide to Minimizing Compressor-based Cooling in Data Centers

Harmonizing Global Metrics for Data Center Energy Efficiency

DataCenter 2020: hot aisle and cold aisle containment efficiencies reveal no significant differences

How to Build a Data Centre Cooling Budget. Ian Cathcart

Overview of Green Energy Strategies and Techniques for Modern Data Centers

Data Centers: How Does It Affect My Building s Energy Use and What Can I Do?

Capgemini UK Infrastructure Outsourcing

Office of the Government Chief Information Officer. Green Data Centre Practices

Managing Power Usage with Energy Efficiency Metrics: The Available Me...

NREL s Plans & Strategies for Building Green Data Centers

Bytes and BTUs: Holistic Approaches to Data Center Energy Efficiency. Steve Hammond NREL

How To Improve Energy Efficiency In A Data Center

Benchmarking results from Indian data centers

Recommendations for Measuring and Reporting Overall Data Center Efficiency

Defining Quality. Building Comfort. Precision. Air Conditioning

Indirect Evaporative Cooling (IDEC) Unit for Data Centers

HIGH PERFORMANCE CHILLED WATER SYSTEMS. EarthWise HVAC. EarthWise HVAC High Performance CHW Plants

Reference Guide: SmartDesign Approach: Common Data Center Challenges:

Case Study: Opportunities to Improve Energy Efficiency in Three Federal Data Centers

Direct Fresh Air Free Cooling of Data Centres

Data Center Technology: Physical Infrastructure

The Data Center Dilemma - A Case Study

International Telecommunication Union SERIES L: CONSTRUCTION, INSTALLATION AND PROTECTION OF TELECOMMUNICATION CABLES IN PUBLIC NETWORKS

STULZ Water-Side Economizer Solutions

Data Center Industry Leaders Reach Agreement on Guiding Principles for Energy Efficiency Metrics

Data Centre Cooling Technologies. Jon Pettitt, EMEA DataCenter Business Development Manager

BCA-IDA Green Mark for Existing Data Centres Version EDC/1.0

7 Best Practices for Increasing Efficiency, Availability and Capacity. XXXX XXXXXXXX Liebert North America

EnergyPro Building Energy Analysis. Assisted Living Building

Transcription:

Greening Data Centers Dallas Thornton SDSC Division Director, Cyberinfrastructure Services March 2, 2011

Data Centers Are Enormous Users of Power US Data Centers (TeraWatt Hours per Year) 125 US Televisions (248 Million Units) 61 27 Sources: Report to Congress on Server and Data Center Energy Efficiency Public Law 109-431; U.S. Environmental Protection Agency ENERGY STAR Program, August 2, 2007; Kaufman, Ron. Television's Hidden Agenda. TurnOffYourTV.com, 2004

Measuring Data Center Facility Efficiency The most common measure is Power Use Efficiency (PUE): [Total Datacenter Electrical Load] PUE = [Datacenter IT Equip. Electrical Load] Source: Green Grid

PUE Tabletop Reference PUE Level of Efficiency 3.0 Very Inefficient 2.5 Inefficient 2.0 Average 1.5 Efficient 1.2 Very Efficient 1.0 Ideal Sources: Green Grid, 2008 UC NAM Data Center Audit, 2009 UCSD/SDSC NAM Data Center Audit, 2010 SDSC/McGill University Joint Data Center Design Typical Server Rooms From office conversions (worst) to basic hot/cold aisle legacy data centers (better) Optimized Data Centers Hot/cold aisle containment, HVAC throttling based on loads, and high efficiency UPSes Greenfield Design in Canada All of the above + innovative climate leveraging technologies and designs

SDSC Data Center Overview ~19,000 sq. ft., 13 MW of on site power Regional co location data center for UC system 100+ projects from 6 campuses Energy efficient alternative to server closets, offices, etc. Home of SD NAP Many 10 Gb and 1 Gb connections to other organizations and networks: CENIC, Cox, Time Warner, Salk Institute, Scripps Research Institute, SDSC, etc.

Optimizing Features Aisle Thermal Containment 15ᵒΔT from top to bottom of rack 1ᵒ ΔT 10ᵒ 15ᵒ increase in return temperatures Cold aisle and hot aisle options Fire code considerations

Optimizing Features (Cont.) Increased Supply Temperatures Move to near top of ASHRAE spec. (80ᵒ F) Drives AHU return temperatures higher, allowing more cooling from chilled water VFD Fans on AHUs Allows for fan energy savings IF accurate controls can be put in place. Adaptive Controls Address redundancy and inefficient cooling Allow big picture control of cooling, throttling based on real time loads

Optimizing Features (Cont.) Rack Blanking Panels Cost effective solutions: Coro plast Floor Brushes Conveyer belt brush: sold in varying lengths Efficient Electrical Systems 480V/277V or (even better) 400V/240V power Efficient UPS and generator configs

SDSC/McGill Data Center Conceptual Design Goal: Most Efficient Class One Data Center in North America Optimize Cooling Systems for Quebec Climate Evaporative free cooling Primary cooling Seasonal ice storage Top up cooling No compressor based cooling 1.06 PUE means UC could potentially recover CapEx in less than 10 years with energy cost savings Lower cost, green hydro power $0.045/kWh vs. $0.08 $0.15/kWh in California Design funded by grants from Canada California Strategic Innovation Partnerships (CCSIP) and CLUMEQ

Free Cooling Analysis with 65F CHWS Humidity Ratio (lbs H2O per lbs dry air) 0.030 0.028 0.026 0.024 0.022 0.020 0.018 0.016 0.014 0.012 0.010 0.008 0.006 0.004 0.002 Data Source: Government of Canada - National Climate Data & Information Archive Data Set: WMO #71627, Montreal/Pierre Elliott Trudeau Airport, Typical Year Elevation: 118 feet Air Pressure: 14.633224 psia Full Free Cooling 7228 hrs/yr 0.000-30 -25-20 -15-10 -5 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 95 100 Dry Bulb Temperature (F) Auxillary Cooling 152 hrs/yr Partial Free Cooling 1380 hrs/yr

Supplemental Cooling: Seasonal Ice Storage Pond System

Supplemental Cooling: Seasonal Ice Storage Pond System

Backup Pay for rental chillers only when (if) you ever need it Design for portable chillers to connect in an emergency

Results Supply Temperatures Annual Energy Use Mechanical Cooling Needed Water Usage Air Cooled Water Cooled Hours of Free Air Cooled Water Cooled Cooling / year PUE Energy Cost ( $0.058/ kwh) Hours per Year 1 Additional Load at Extreme Weather (wetbulb = 68.7 F) Evaporation + Carry Over Blowdown C F C F hrs/yr % of yr kwh/yr 2 $ tons gallons gallons $ Cost ($5.52/1,000 gal) 10% 90% 29.4 85.0 23.9 75.0 8,532 97% 1.06 74,543,000 $4,323,000 228 0 33,200,000 8,100,000 $228,000

Potential Facility Related Cost Savings Assumptions 5 MW IT Load 24x7 Operation Typical Local DC 2.0 PUE 10 MW Consumption $0.10/kWh Power Costs $8.8M Power Bill Efficient Local DC 1.35 PUE 6.75 MW Consumption $0.10/kWh Power Costs $5.9M Power Bill Ultra-Efficient 1.06 PUE 5.3 MW Consumption $0.05/kWh Power Costs $2.3M Power Bill Potential Cost Savings of 74% and Energy Savings of 47% Though Facility Changes Alone!

Anyone who knows all the answers most likely misunderstood the questions.