Surface Technology. Centrifugal Fan GMD



Similar documents
O-I DUBI PLANT FANS Quotation Spec Data & Specifications


Chapter 3.5: Fans and Blowers

Centrifugal Fans and Pumps are sized to meet the maximum

Filter Fan Unit SILENT. Type SILENT AC Type SILENT EC

Max. Head (m) LVR V , Hz ~ 220 V Oval Flange G1. LVR V , Hz ~ 380 V Oval Flange G1

Technical Concept. Filter Fan Unit COMPACT. Type COMPACT AC Type COMPACT EC

systemair Smoke Extract Fans Keep Your Cool: Smoke Extraction with Systemair

SUNON SPECIFICATION FOR APPROVAL

Transformer oil cooler ALFA A02

TFSR & TFSK Roof Fans

Energy Saving ECM Motors and Fans Ventilation Catalogue

SUNON SPECIFICATION FOR APPROVAL DESCRIPTION : DC BRUSHLESS FAN. DIMENSIONS : 60X60X15 mm M O D E L : KD0506PHS2

CRN5-5 A-FGJ-G-E-HQQE 3x230/400 50HZ

Eurovacuum EV Series. Single Stage Oil Sealed Rotary Vane Pump

CDX. EBARA PUMPS EUROPE S.p.A. CENTRIFUGAL PUMPS. Page - CONTENTS 100

AC axial fans A series

CRN A-F-G-E-HQQE 3x400D 50 HZ

TD-SILENT Series (160 to 1000 models) TD-SILENT Series (1300 and 2000 models) NEW TD-SILENT. In-Line duct fans

FAN & BLOWER CENTRIFUGAL FANS

HP switch LP switch Discharge thermo Comp. Surface thermo

technical data air conditioning systems RXS E (single phase) FBQ-B8V1-B8V3B Split Heat Pump Condensing Units Split Sky Air

Electronic, Digital and Mechanical Vibration Switches

How To Save Energy On A Power Supply

T1-40 T1-40BF T1-40V T1-38 T1-38BF T1-38V

T1-40 T1-40BF T1-40V T1-38 T1-38BF T1-38V

PHOTOVOLTAIC (PV) solar panels. Specification. Electricity - CE & ISO 9000 certified. 83W panel. 180W panel Maximum power:

Tilt switches N3 / N4... MEMS technology, one or two axis. Use. Options. + long lifetime and highly reliability due to mechanism-free MEMS technology

ECOCIAT. Domestic hot water heat recovery unit

4" SUBMERSIBLE PUMPS

Heat Pump Product Brochure 2015/2016. Premier Series Hi-Wall Split Systems. Everyday Comfort

Elegant ECM. ELEGANT ECM air conditioners allow. The range is made up of 12 models: Ceiling Air Conditioner

Data Center Cooling. The engineer s choice

OPERATING MANUAL CONTRACTOR STYLE AXIAL FANS

Multistage high-pressure multistage centrifugal pumps

hore PRODUCT CATALOGUE nd Offsh arine an ms for Ma & Refrig AUTONOMOUS AIR CONDITIONERS HV VAC &

Photovoltaic Solar Energy Unit EESFB

Operating instructions

UDSA - UDSBD unit heater

FLEXIT S3 X/TT A3 X/TT K3 X/TT S3 R S3 RK

DSRQ - DSRSQ - DSRSQ-THERM

Air Comfort. Technical Catalogue > Roof Fan STOF

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM

Max primary circuit temperature 90ºC Max primary circuit temp. 90ºC Max secondary circuit temperature 45ºC Max secondary circuit temp.

Under sill units. Type FSL-B-ZAS

CADB and CADT-D / DI / DC Series

RFHD. ROOF CENTRIFUGAL FANS WITH ATEX CERTIFICATION CEE ExII2G Ex d. According EU Regulation

SERVICE INSTRUCTION R410A. SPLIT TYPE ROOM AIR CONDITIONER Universal Floor / Ceiling Duct / Cassette Wall Mounted / Floor type INVERTER MULTI

Operating instructions

Operation Instructions. KleeBlower Compressor/Vacuum pumps. Models: KB129 KB8415

ELECTROPUTERE ROTATING ELECTRICAL MACHINES DIVISION

EXPLOSION-PROOF EMERGENCY LIGHTING FIXTURE FOR FLUORESCENT LAMP EVF-..-EL SERIES

PUMP VIBRATION STANDARDS GUIDELINES

SWIMMING POOL AIR-HANDLING UNITS KU-DB Series

Development and testing of a multi-type air conditioner without using AC inverters

- CONSTRUCTIONS 300 SECTIONAL VIEW 300 MECHANICAL SEAL DIMENSIONS AND WEIGHT 400 PUMP 400 PACKING 401

ICQ Series - square centrifugal

Description. Dimensions. Features. precision works better

Installation, operation and maintenance manual TX 35A

Cooking at the Speed of light!

Standard offering (pumps)

14. Troubleshooting Guide

THE ErP DIRECTIVE 2009/125/EC KEY FACTS» REGULATIONS 327/ /2009. ErP. - Version 2.0

Swirl diffuser VSKA. Product facts. Quick selection. Swirl diffuser VSKA. Connection box ATTB. Product code example:

Heating, air-conditioning, cooling

Performance Rating of Room Fan- Coils

ebm-papst North America

industry revolves around

Commercial Gas Furnace Upflow

CLOSE CONTROL SYSTEM. PFD series provide you with highly reliable computer room cooling system. High Reliability

What Is Regeneration?

Conlift1, Conlift2, Conlift2 ph+

BSM MOTOR DRIVEN CENTRIFUGAL PUMPS

SASO XXXX:2016. (Including the modifications approved in Saudi Council Board No. XXX/2016) LARGE CAPACITY AIR CONDITIONERS

HEAVY DUTY STORAGE GAS

Failure code manual. content

CORONA E / FLYPPER ELECTRONIC METER MULTI-JET

DESIGN & TECHNICAL MANUAL

Pump Specifications 250 Series Submersible Sump / Effluent Pump 2 Solids handling

Titan Makina Ltd. Şti Sok. No: 9 Ostim Ankara Tel: Fax: Web:

CE Marking to BS EN

32:(5#5$7,1* 4833#USP283#+] 4;33#USP293#+] 3ULPH 113 kva, 90 kw 124 kva, 99 kw 6WDQGE\ 114 kva, 91 kw 125 kva, 100 kw

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

Centrifugal Fans direct driven with scroll. Issue 1.3 November 2012

USER S MANUAL FH052EAV1 FH070EAV1. System Air Conditioner (Cooling and Heating) ENGLISH ESPAÑOL FRANÇAIS ITALIANO PORTUGUÊS DEUTSCH E HNIKA

Ferrostat Speed Sensor Series DSF Explosion Proof Versions EEx

REGULINE 600VA / 1000VA REGULATOR USER MANUAL

38 Series - Relay interface modules A

Technical Service Manual. Version One

Operating instructions

Dehumidifier D 850E. - Instruction manual version 02

LG Air Conditioning Multi F(DX) Fault Codes Sheet. Multi Split Units

Portable Evaporative Air Cooler for Outdoor, Indoor & Commercial Use. OWNER S MANUAL Read and save these instructions before use.

COOLSIDE box R410A. conditioned server - racks for direct installation into the room INVERTER E C

Fan Basics and Selection Criteria (How to Use)

Product Data Bulletin

FLEXIT S4 R S6 R S7 R

LED DOWNLIGHT ONE 50XX SERIES

T15 AIR CONDITIONER INSTRUCTION MANUAL FOR: McLean Thermal Business Park Blvd. N Champlin, MN Tel: Fax:

Transcription:

Centrifugal Fan ATEX classed adapted for paint shops Wide assortment broad area of application Service friendly low maintenance costs Headquarters:

Centrifugal Fan Centrifugal Fan is a direct driven industrial blower that works with a high degree of efficiency. Blowers are available with two different types of impeller depending on the type of application. The B-impeller has backward curved blades and is intended for relatively clean air. The P-impeller has backward inclined blades and is intended for both clean air and air with some dust content. The B-impeller operates with an efficiency of up to 86% and the P-impeller with an efficiency of up to 75%. All models are available in ATEX versions for Category 3G (Zone 2), inward (only process air) or inward and outward. The blowers are delivered powder coated as standard. Designator code - XX- A- B- C kw- Zon D/ E Fan type Greiff - Mean pressure - Direkt driven Size 31 50 63 71 Impeller B P Nominal speed 4 = 1450 rpm 6 = 950 rpm 8 = 750 rpm Engine output kw ATEX Class inward fan (process air) - = Unclassified 2 = zone 2 (3G) ATEX Class outward fan (outdoor air) - = Unclassified 2 = zone 2 (3G) Headquarters:

Centrifugal Fan Table of Measures Type A B C D E F* G H K 31 315 200 315 298 529 491 634 255 34 50 500 315 500 530 905 675 11004 401 25 63 560 400 630 600 10158 801 250 492 165 71 630 450 630 660 11209 301 410 560 190 *Varies somewhat depending on engine size Headquarters:

Centrifugal Fan Capacity Diagram 31-B (B-impeller) 31-B 31-B Headquarters:

Centrifugal Fan Capacity Diagram 50-B (B-impeller) 50-B 50-B Headquarters:

Centrifugal Fan Capacity Diagram 63-B (B-impeller) 63-B 63-B Headquarters:

Centrifugal Fan Capacity Diagram 71-B (B-impeller) 71-B 71-B Headquarters:

Centrifugal Fan Capacity Diagram 31-P (P-impeller) 31-P 31-P Headquarters:

Centrifugal Fan Capacity Diagram 50-P (P-impeller) 50-P 50-P Headquarters:

Centrifugal Fan Capacity Diagram 63-P (P-impeller) 63-P 63-P Headquarters:

Centrifugal Fan Capacity Diagram 71-P (P-impeller) 71-P 71-P Headquarters:

Centrifugal Fan SAFETY & OPERATION Fans are fitted with a 3-phase short circuit motor. Fans are intended for continuous operation. The fan s outdoor temperature should be 40 C max. The temperature of the media transported by the fan should be max. +80 C. (NOTE! max +40 C applies for ATEX classed fans). Fans can be installed vertically or horizontally. Fans are approved for regulating the speed with frequency inverter. (NOTE! Special instructions for frequency control apply for the outer side of ATEX classed fans Cat.3G (zone 2)). Lowest modulated operating frequency for Motors is 20Hz. (NOTE! Special instructions for frequency control apply for the outer side of ATEX classed fans Cat.3G (zone 2)). Calculation of the highest operating frequency for motors is based on the maximum speed for the specific fan type, see fan curve of the relevant fan. (NOTE! Special instructions for frequency control apply for the outer side of ATEX classed fans Cat.3G (zone 2)). The fan motor should be connected with an over current protection that is set to the rated current for the specific motor and that breaks the voltage supply to the motor if the rated current is exceeded. (NOTE! Special instructions for frequency control apply for the outer side of ATEX classed fans Cat.3G (zone 2)). INSTALLATION, OPERATION & MAINTENANCE Prior to commissioning, the fans must be duct connected or fitted with protection guards to prevent contact with any moving parts. The fans are only intended for fixed installation. Installation should be performed in a manner that ensures it cannot unfasten, cause or be exposed to any vibrations. If the installation can result in a situation whereby the fan is subjected to vibrations, it should be mounted on vibration absorbers and duct connected with diffusers. The fan should be so installed that service and maintenance can be carried out in the easiest and safest way possible. For ATEX classed fans, a number of safety measures should be taken to ensure that no foreign objects can be sucked or fall into the fan, min IP20 ( 12,5mm) on the inlet side and IP10 ( 50mm) on the outlet side. For ATEX classed fans Cat.3 (zone 2) inside (NOT classified outside) the fan outlet must be duct connected so that the duct outlet discharges at least 1,500mm away from the fan motor. If the fan is installed in an area where there is a risk of formation of condensation (e.g. outdoors with varying temperatures), the drainage plugs on the motor should be opened to ensure that they are placed at the lowest point of the framework so that the condensation water can run out. (NOTE! Special instructions apply for the outer side of ATEX classed fans Cat.3G). Prior to commissioning, make sure that: 1. The fan is installed and electrically connected properly, safely grounded and with motor protection. 2. No foreign objects are in the fan. 3. The rotation direction is in accordance with the label. (if the fan rotates in the wrong direction, two phases can be swapped to attain the correct direction) 4. The current strength does not exceed that stated on the Motor. Headquarters: