1 94111E FLEXIT S4 R S6 R S7 R User Manual Air Handling Unit Cabinet Models with Heat Recovery - Rotor
2 Contents 1 Important Safety Instructions Method of Operation - System Heating Elements System Drawing Operation - Control Troubleshooting Cleaning - Maintenance General Drawings Overview Drawing, S3 R/S6 R/S7 R Technical Data Technical Data, S4 R Technical Data, S6 R Technical Data, S7 R Dimensioned Drawings Unit Adjustment Options Adjustment Control Card Adjustment Options CE Declaration of Conformity Symbols Used This product has a number of symbols that are used to label the product itself and in the installation and user documentation. Here is an explanation of some of the commonest symbols. DANGER! ELECTRICITY DANGER! DO NOT TOUCH SUPPLY AIR EXTRACT AIR EXCHANGER/SUMMER CASSETTE HEATING THERMOSTAT EXHAUST AIR OUTDOOR AIR Symbols for units/electric heating TRANSFORMER ADJUSTMENT SUPPLY AIR STAGE 2 TRANSFORMER ADJUSTMENT EXTRACT AIR STAGE 2 Our products are subject to continuous development and we therefore reserve the right to make changes. We also disclaim liability for any printing errors that may occur. 2
3 1 Important Safety Instructions! To reduce the risk of fire, electric shock or injury, read all the safety instructions and warning texts before using the unit. This unit is only designed to handle ventilation air in buildings. It must not be used to extract combustible or flammable gases. Remove the power plug before commencing any service and maintenance work. Before you open the door, the unit must be dead and the fans must be given time to stop (min. 2 minutes). The unit contains heating elements that must not be touched when they are hot. The unit must not be operated without the filters being in place. Follow the user manual precisely. 2.2 System Drawing Supply air Extract air Exhaust air Outdoor air B1 FI2 M2 FI1 P1 To maintain a good indoor climate, comply with regulations and avoid condensation damage, the unit must never be stopped apart from during service/maintenance or in connection with an accident. F10 F20 HR-R 2 Functional Description M1 EB1 M4 In the rotor HR-X, the cold outdoor air and the warm extract air pass each other without being mixed. With this principle, approximately 80-90% of the heat in the extract air will be transferred to the supply air. In addition, a thermostat-controlled heating element EB1 will ensure that the supply air has the desired temperature if the outdoor temperature falls very low. This supply air is passed via ducts and valves to living rooms and bedrooms. The extract air is extracted either from the same room or via door gaps/overflow gratings to toilets and wet rooms. The used air is passed via a duct system back to the unit, emits heat as stated above and is blown out of the building via a roof hat or wall grating. The temperature of the supply air is controlled by the rotor. The heating element will not start up until the rotor is unable to maintain the set temperature. When there is no need for heating (summer), the rotor will stop. B1 SUPPLY AIR TEMPERATURE SENSOR EB1 HEATING ELEMENT F10 OVERHEATING THERMOSTAT F20 OVERHEATING THERMOSTAT FI1 SUPPLY AIR FILTER FI2 EXTRACT AIR FILTER M1 SUPPLY AIR FAN M2 EXTRACT AIR FAN HR-R ROTOR HEAT EXCHANGER M4 ROTOR MOTOR 2.1 Heating Elements The heating elements are protected against overheating by the overheating thermostat F20, which switches off at 65 C. As an additional safety measure, the overheating thermostat F10 switches off at 80 C. The overheating thermostat can be reset manually by removing the white plastic cover and pressing the reset button. The thermostat is accessible once the doors are open. It is located at the bottom of the compartment right above the heating element. See the label - RESET. This is purely a ventilation system and not a heating system. The home must be heated in the normal manner. The heat gained from heat recovery must be seen in relation to a situation in which the extract air is blown right out of the home without recovery. 3
4 3 Operation - Control The speed of the fans in the unit is controlled from a separately mounted SP 30 control switch. Depending on the operating situation, the fan speed is set to the desired level. MIN stage: NORMAL stage: MAX stage: Used when not as much ventilation as normal is required. Normal operating ventilation. This is the position for daily operation. Used when increased ventilation is required in wet rooms or throughout the flat. Must be used during and for a while after showering and clothes drying, for example, to avoid condensation in the ducts. Red Green Yellow If there is a power cut, the until will automatically be set to the speed stage Normal and rotor active when it restarts, i.e. the rotor will operate if heating is required. SP 30 Control Switch for Electronic Automatic Control with a Thermoguard This contains the following functions: - Right pressure switch (fan symbol) to choose between min, normal and max speeds with an indicator lamp to show which speed stage is active. - Left pressure switch (+ symbol) to choose heating OFF/ON. This switch is used to switch the rotor and heating element off/on (disconnected during the warm part of the year). The temperature adjustment (item no. 3 /Chap. 6) is factory-set to 20 C in the unit and should not be set to over 25 C. The temperature is adjusted with a flat screwdriver. The temperature sensor is located in the supply air duct. Some heat loss up to the valves must be expected where ducts pass through a cold environment. - Red lamp (!): Slow flash: Filter must be replaced (provided that a pressure guard is installed). Fast flash: Overheating thermostat triggered. Permanently on: Both errors - Green lamp (+): This lights when the rotor and heating are active. - Yellow lamp ( C): This lights when the rotor is in operation (the rotor stops when heating is not required). 4
5 4 Troubleshooting FAULT If the fans are not working or cannot be adjusted If the supply air feels too cold If the air flow rate has been seriously reduced DO THE FOLLOWING Check that the power plug is correctly inserted in the power point. Check that the fuses in the electrical cabinet are switched on. The overheating thermostat (item no. 5/Chap. 6 General Drawings) may have been triggered. Reset as described. Check that the control switch + is activated. The green and yellow lamps light. Check that the drive belt for the rotor (8) is intact and in place. The heating thermostat (3) can be set to a higher temperature. The overheating thermostat (5) may have been triggered. Reset as described. The filters (item nos. 1, 2) may be clogged by dirt. Clean or replace them. See under Cleaning - Maintenance. The grille in the outdoor air cap may be clogged. See under Cleaning - Maintenance. If none of this helps, please contact your supplier for service. Please state the serial number on the rating plate inside the unit (open the door). 5 Cleaning - Maintenance! Before opening the door of the heat recovery system or carrying out maintenance on the kitchen hood: switch off the heat, let the fans continue for three minutes to remove hot air, remove the power from the unit and wait 2 minutes before opening the doors. Doors: Opened by unscrewing the two screws in one door. Fans: Item nos. 6 and 7/Chap. 6 General Drawings. The fans normally do not need to be inspected. If necessary, the fan blades may be cleaned with a small brush and compressed air, if possible. NB! Do not use water. Disassemble as follows: Open the doors as directed. Pull out the electric quick-release contact for the motor. Unscrew 2 screws under the front edge of the motor s mounting plate. The fan can then be carefully pulled down and out of the unit. 5
6 Filters:! To preserve a healthy indoor environment, it is important to change filters when they are dirty. Dirty filters lead to: Increased air resistance in the filter less air in the home the risk of bacterial growth in the filter in the worst case scenario, the system can be damaged. How often the filters need to be changed depends on the degree of contamination of the air where they are installed. In general, the filters need to be changed once a year, preferably in the autumn (after the pollen season). In areas with a lot of dust and contamination, the filters should be changed in the spring and autumn. The supply air filter and extract air filter (2 and 1) consist of an EU 3 prefilter on top (coarse filter) and a compact filter (EU7). They are pushed into place and fastened with filter tighteners. It is recommended that you order a filter subscription to ensure full benefit from the system and the cheapest prices. Order no. for a complete set of filters: Rotor model filter location (the drawing shows the right model/the left model is inverted) Supply air filter: Prefilter and compact filter Extract air filter: Prefilter and compact filter Rotary wheel-type exchanger Rotor: The rotor (8) should be checked roughly once a year for dust and dirt in the air ducts. If you find signs of clogging, contact your supplier for service. Check also that the round belt is intact and tight. Valves and duct system: The valves should be cleaned at least once a year. The duct system should be cleaned at least every 10 years. Outdoor air intake: Roof hat: Summer operation: Check once a year that the grille is not clogged with leaves, dust and dirt. Check once a year that the drainage gap at the bottom is not clogged with leaves. This applies only if the system has a roof hat. During the warm part of the year (outside the heating season), there is no need to recover heat. The switch + on the control switch can be pressed in so that the green lamp + goes out. This avoids heat recovery on cool nights, and the house is not heated as fast during the daytime. When heat recovery is required again, press the switch + so that the green lamp lights again. 6
7 6 Overview Drawing S4 R/S6 R/S7 R Outdoor air Exhaust air Extract air Supply air Left model (right model inverted) Item Part no. 1 G3 + F7 extract air filter 2 G3 + F7 supply air filter 3 Heating adjustment 4 Heating battery 5 Overheating thermostat 6 Supply air fan 7 Extract air fan 8 Rotary wheel-type exchanger 9 Rotor motor 4 9 7
8 7 Technical Data 7.1 Technical Data, S4 R 7.3 Technical Data, S7 R Rated voltage 230 V/50 Hz Rated voltage 230 V/50 Hz Fuse 10 A Fuse 16 A Rated current, total 6.7 A Rated current, total 14.2 A Rated power, total 1545 W Rated power, total 3265 W Rated power, electric battery 1200 W Rated power, electric battery 2500 W Rated power, fans 2 x 165 W Rated power, fans 2 x 375 W Rated preheating power Rated preheating power Fan type F-wheel Fan type F-wheel Fan motor control Transformer Fan motor control Transformer Max. fan speed 2230 RPM Max. fan speed 2000 RPM Standard automatic control SP30 Standard automatic control SP30 Filter type (SUP/EXTR) F7/F7 Filter type (SUP/EXTR) F7/F7 Filter dimensions, SUP (WxHxD) Filter dimensions, EXTR (WxHxD) 468x200x50 mm 468x200x50 mm Filter dimensions, SUP (WxHxD) Filter dimensions, EXTR (WxHxD) 468x200x50 mm 468x200x20 mm Weight 85 kg Weight 92 kg Duct connection Dia. 200 mm Duct connection Dia. 200 mm Height 900 mm Height 900 mm Width 900 mm Width 900 mm Depth 550 mm Depth 550 mm 7.2 Technical Data, S6 R Rated voltage Fuse Rated current, total Rated power, total Rated power, electric battery Rated power, fans Rated preheating power Fan type Fan motor control Max. fan speed Standard automatic control Filter type (SUP/EXTR) Filter dimensions, SUP (WxHxD) Filter dimensions, EXTR (WxHxD) Weight Duct connection Height Width Depth 230 V/50 Hz 10 A 9.8 A 2255 W 1700 W 2 x 270 W F-wheel Transformer 2150 RPM SP30 F7/F7 468x200x50 mm 468x200x50 mm 86 kg Dia. 200 mm 900 mm 900 mm 550 mm 8
9 8 Dimensioned Drawings S4 R/S6 R/S7 R Left Right * Measures in mm 9
10 9 Adjusting the Unit! Before opening the door of the heat recovery system or carrying out maintenance on the kitchen hood: switch off the heat, let the fans continue for three minutes to remove hot air, remove the power from the unit and wait 2 minutes before opening the doors. 9.1 Adjustment The speed of the unit at the normal stage must be set to the voltage specified in the Documentation of Ventilation Data form that is enclosed with the ventilation drawings from the company responsible for project planning. Open the door and unscrew and remove the cover of the automatic control compartment. The transformer is then visible and the cables marked (as shown on page 2) can be switched over to the specified voltage level. Extract air Supply air S4 R/S 6R/S 7R: The automatic control compartment is in a space Factory setting 150 V 150 V behind the cover above the heating element. 9.2 Control Card Adjustment Options Dipswitch Rotor unit control card Dipswitch OFF no. 1 Not used Not used ON 2 Must be in this position Not used 3 Not affected with nighttime temperature reduction 4 Not affected with nighttime temperature reduction Temperature is reduced by 3 C with night-time temperature reduction Fan speed is reduced to low with nighttime temperature reduction 5 Heating not available Heating available 6 Not used Must be in this position Bold type shows the standard factory setting. All settings can be combined. 10
11 10 CE Declaration of Conformity This declaration confirms that the products meet the requirements in the following Council Directives and standards: 89/336/EEC Electromagnetic compatibility (EMC) 73/23/EEC Low-voltage Directive (LVD) 89/392/EEC Machinery Directive (MD) EC :91 + A1:94 + A2:99 EN :94 + A11:95 + A1:96 + A13:98 + A14:98 + A15:00 + A2:00 + A16:01 EN :92, EN :97 Manufacturer: Equipment group: Type: FLEXIT AS, Televeien 15, N-1870 Ørje Ventilation units for installation in ducts S4 R S6 R S7 R The product is CE-marked: 2002 FLEXIT AS 20/09/2002 Pål J. Martinsen General Manager The right to give notice of lack of conformity applies to this product in accordance with the existing terms of sale, provided that the product is correctly used and maintained. Filters are consumables. The symbol on the product or on its packaging indicates that this product may not be treated as household waste. Instead it shall be handed over to the applicable collection point for the recycling of electrical and electronic equipment. By ensuring this product is disposed of correctly, you will help prevent potential negative consequences for the environment and human healthe, which could otherwisw be caused by inappropriate waste handeling of this product. For more detailed information, please contact your local city office, your household waste disposal service or the shop where you purchased the product. Notice of lack of conformity as a result of incorrect or defective installation must be submitted to the installation company responsible. The right to give notice of lack of conformity may lapse if the system is used incorrectly or maintenance is grossly neglected. 11
12 Flexit AS, Televeien 15, N-1870 Ørje, Norway
94122E-05 2005-10 FLEXIT L4 X/TT L7 X/TT. User Manual. Air Handling Unit Loft Models with Heat Recovery
94122E-05 2005-10 FLEXIT L4 X/TT User Manual L7 X/TT Air Handling Unit Loft Models with Heat Recovery Contents 1 Important Safety Instructions...3 2 Method of Operation - System...3 3 Operation - Control...4
94210E-03 2005-10 L7 X W. User Manual. Air Handling Unit Loft Models with water-based heating
94210E-03 2005-10 FLEXIT L4 X W L7 X W User Manual Air Handling Unit Loft Models with water-based heating Contents 1 Important Safety Instructions... 3 2 Method of Operation - System... 3 3 Operation -
Flexit air handling unit K2 R
Flexit air handling unit K2 R with integrated kitchen hood PATENTED The quietest on the market Modern design Energy-efficient Installation in the kitchen A FOR A HEALTHY ENVIRONMENT Requirement-controlled
FLEXIT S3 X/TT A3 X/TT K3 X/TT S3 R S3 RK
944E-05 006-0 FLEXIT S X/TT A X/TT K X/TT S R S RK Installation Instructions Air Handling Unit/ Kitchen Model S X/TT K X/TT A X/TT S R S RK Air handling unit with cross heat exchangeror TT exchanger Air
NEW! Flexit SL4 R. Air Handling Unit with rotating recovery system Energy-efficient New control system. Patent applied for!
Flexit SL4 R Air Handling Unit with rotating recovery system Energy-efficient New control system NEW! Patent applied for! - Simple settings - Flexible installation - User friendly F O R H E A LT H Y I
Flexit SPIRIT K2R. Air handling unit with integrated kitchen hood
Flexit SPIRIT K2R Air handling unit with integrated kitchen hood The quietest on the market Modern design Energy-efficient Installation in the kitchen Flexit SPIRIT - a new generation of air handling units
News! Flexit S20 R. Air Handling Unit. A new generation of Air Handling Units. For a healthy indoor envionment
News! Flexit S20 R Air Handling Unit A new generation of Air Handling Units For a healthy indoor envionment Flexit S20 R Air Handling Unit Flexit is launching a new range of air handling units with capacity
111538E-05 2012-11. Flexit SPIRIT UNI 2. Installation Instructions. Air Treatment Unit & Automatic Control
111538E-5 212-11 Flexit SPIRIT UNI 2 Installation Instructions Air Treatment Unit & Automatic Control Contents 1 Planning and preparation work 4 1.1 Joiner / fitter 4 1.2 Plumber (if the unit has a water
Installation and maintenance instructions. Danfoss Vent
Installation and maintenance instructions Danfoss Vent 1 Unit design... 2 2 Project planning and installation instructions... 3 2.1 Ventilation...3 2.2 Piping installation....3 2.3 Condensation line...4
Carpet Washer. vax.co.uk VRS5W. Vax Careline: (UK) 0844 412 8455 (ROI) 1-800 928 308. Vax model number: Version 1.0
VRS5W Powermax User Guide V1.0.qxd:V1.0 23/7/10 15:35 Page 1 Vax Careline: (UK) 0844 412 8455 (ROI) 1-800 928 308 Carpet Washer Vax model number: VRS5W instruction manual Version 1.0 Please read carefully
USER INSTRUCTIONS FOR 10 LITRE PORTABLE DEHUMIDIFIER MODEL NO. DHMD102
USER INSTRUCTIONS FOR 10 LITRE PORTABLE DEHUMIDIFIER MODEL NO. DHMD102 THANK YOU FOR CHOOSING YOUR NEW DEHUMIDIFIER. BEFORE USING THE UNIT READ THESE INSTRUCTIONS FULLY AND RETAIN THEM FOR FUTURE REFERENCE
Infrarot-Bewegungsmelder IP44
Infrarot-Bewegungsmelder IP44 infrared motion sensors IP44 ODA (weiß) slim ODA (schwarz) slim 95174 96000 ODA (weiß) ODA (schwarz) 95175 96001 Betriebsanleitung User s Manual User s Manual infrared motion
MODEL: DV72. Mechanical Ventilation with Heat Recovery Installation Instructions and User Manual. Configuration Left Hand Right Hand
9041381- Issue 6 4/11 MODEL: DV72 Mechanical Ventilation with Heat Recovery Installation Instructions and User Manual Commissioning Data: to be completed by the installer Date of installation: Configuration
MICA HEATER INSTRUCTION MANUAL Model No: UHM-786 230V 50Hz 2200W
MICA HEATER INSTRUCTION MANUAL Model No: UHM-786 230V 50Hz 2200W Safety Precautions To reduce the risk of personal injury or damage to property, basic safety precautions must be observed including the
Meaco 30L and Meaco 40L dehumidifier instruction manual
Meaco 30L and Meaco 40L dehumidifier instruction manual Please read this instruction manual before using the dehumidifier and keep safe for future reference SAFETY INSTRUCTIONS PLEASE READ ALL INSTRUCTIONS
USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR
USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR CONTENTS Introduction Safety Notes Identification of parts Installation instructions Operation instructions Maintenance Troubleshooting
Portable Air Conditioner
Portable Air Conditioner Owner's Manual Model:3 in 1 12,000 Btu/h Series 3 Please read this owner s manual carefully before operation and retain it for future reference. CONTENTS 1. SUMMARY...1 2. PORTABLE
Important Safeguards
Table of Contents Important Safeguards...2 Product Layout...3 Preparing for Use...4 Air-conditioning without installation...4 Air-conditioning with installation...5 Control Panel...6 Operating from the
User Guide. Bagless Cylinder White. Get Cleaning... vax.co.uk. Vax Careline: (UK) 0844 412 8455 (ROI) 1-800 928 308. White series
C88-VW-B UG [Update 10.05.12]_User guide 10/05/2012 09:40 Page 1 User Guide Vax Careline: (UK) 0844 412 8455 Bagless Cylinder White Get Cleaning... What s your Vax model number? (Located on the top flap
User s Manual Before using the inverter, you need to read and save the safety instructions.
User s Manual Before using the inverter, you need to read and save the safety instructions. STI SERIES (STI200, STI300, STI500, STI700, STI1000) Power Frequency Pure Sine Wave Inverter The information
User Manual THR840DUK Digital Thermostat
User Manual THR840DUK Digital Thermostat 50051982-001 Rev. A WARNING: This product must be correctly installed and configured to work properly (see pages 12-24). If you are not experienced in wiring electrical
INFRARED QUARTZ WALL HEATER
INFRARED QUARTZ WALL HEATER MODEL NO: IQ2000 PART NO: 6939004 MOUNTING & OPERATION INSTRUCTIONS GC0715 INTRODUCTION Thank you for purchasing this CLARKE Infrared Wall Heater. Before attempting to use this
Accessories SUNNY REMOTE CONTROL
Accessories SUNNY REMOTE CONTROL Mounting Instructions SRC20-MO-IEN121010 IMEN-SRC20 Version 1.0 EN SMA Solar Technology AG 1 Information on this Document 1 Information on this Document Validity This
Dehumidifier Users manual. For Models: DH45S DH65S
Dehumidifier Users manual For Models: DH45S DH65S 950-0062-revD Jan. 9 2007 FORWARD The appearance of the units that you purchase might be slightly different from the ones described in the Manual, but
NewAir AC-10000E, AC-10000H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS
NewAir AC-10000E, AC-10000H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS BEFORE USE GENERAL SAFETY INSTRUCTIONS: ALWAYS OPERATE THE UNIT IN AN UPRIGHT POSITION AND PLACE
FLUORESCENT UV- RING LIGHT OPERATING INSTRUCTION
FLUORESCENT UV- RING LIGHT OPERATING INSTRUCTION Caution! UV-radiation of this device is in the range of UV-A (320-400 nm). Direct exposure to eyes shall therefore be avoided. UV protection glasses shall
Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MF08CESWW. Voltage rating: 115V~60Hz Power rating : 800W
MODE ALARM Portable Air Conditioner OWNER S MANUAL Read these instructions before use 8 Model: MF08CESWW Voltage rating: 115V~60Hz Power rating : 800W Customer Support : 1-800-474-2147 For product inquiries
2-SLICE COOL TOUCH TOASTER
2-SLICE COOL TOUCH TOASTER PLA0405 Instruction Manual Due to on-going product improvements, specifications and accessories may change without notice. Actual product may differ slightly to that depicted.
- 2 - IMPORTANT SAFETY REMINDERS
USER MANUAL IMPORTANT SAFETY REMINDERS This appliance should only be used for domestic cleaning, as described in this user guide. Please ensure that this guide is fully understood before operating the
Topvex SX/C, Topvex TX/C. Air Handling Unit
Air Handling Unit Document in original language 131677-EN_GB 23-12-2015 A001 Contents 1 Declaration of Conformity... 1 2 Warnings... 2 3 Product information... 2 3.1 General... 2 3.2 Technical data...
Accessory Manual Ventilation Section Model Comfort Circle
Accessory Manual Ventilation Section Model Comfort Circle Manual version:. R a Copyright and trademarks All the information and drawings in this manual are the property of Biddle and may not be used (other
Drayton Digistat +2RF/+3RF
/+3RF Programmable Room Thermostat Wireless Model: RF700/22090 Model: RF701/22092 Power Supply: Battery - Thermostat Mains - Digistat SCR Invensys Controls Europe Customer Service Tel: 0845 130 5522 Customer
SHOWER WATER HEATER MODEL BS 35 / 45 / 60 BS 35 E / 45 E / 60 E OPERATION AND INSTALLATION INSTRUCTIONS
SHOWER WATER HEATER MODEL BS 35 / 45 / 60 BS 35 E / 45 E / 60 E OPERATION AND INSTALLATION INSTRUCTIONS 2 This water heater must be installed (water and electrical installation), commissioned and serviced
VACUUM CLEANER INSTRUCTION MANUAL
VACUUM CLEANER INSTRUCTION MANUAL MODEL: SVC9702 PLEASE READ THIS MANUAL CAREFULLY BEFORE USING AND KEEP IT PROPERLY FOR FUTURE USE 1 Safety Cautions: WARNING: To reduce the risk of fire, electrical shock,
V94 BULK TAPE DEGAUSSER
TECHNICAL MANUAL Operating and Maintenance Instructions for V94 BULK TAPE DEGAUSSER V94 BULK TAPE DEGAUSSER TECHNICAL MANUAL Document No. M000208 Production Standard ZZ 009 415 WARNING To help minimise
Network Time Accessories LED CLOCK. (for NTP Synchronization)
Network Time Accessories LED CLOCK (for NTP Synchronization) 1 Table of Contents 1. Specification... 3 2. Introduction... 3 3. User safety... 3 4. Assembly notes... 4 5. LAN (Ethernet)... 5 6. Relay control...
Contact Details. Please note that some of the contact details on this PDF document may not be current.
Contact Details Please note that some of the contact details on this PDF document may not be current. Please use the following details if you need to contact us: Telephone: 0844 879 3588 Email: [email protected]
CELO5. User & Installation Manual. www.audac.eu
CELO5 User & Installation Manual www.audac.eu 2 Introduction 5 High-end Slim Ceiling Speaker The CELO5 is the 5 version of AUDAC s CELO High-end Slim ceiling speaker series with an RMS power of 50 Watt
IH 17025 E Sigma Island 90
INSTRUCTIONS FOR USE Kitchen extractor hood Type: IH 17025 E Sigma Island 90 Dear Customer!! You are now a user of the newest generation kitchen extractor hood type IH 17025 E Sigma Island 90. This hood
ecomax Instructions for use Wall hung room sealed fan assisted condensing boilers For the user
For the user Instructions for use ecomax Wall hung room sealed fan assisted condensing boilers ecomax 63/ E ecomax 68/ E ecomax 6/ E ecomax 635 E ecomax 84/ E ecomax 88/ E ecomax 835 E GB Table of contents
4P359542-1H. Wireless LAN Connecting Adapter <BRP069A41> Installation Manual
4P359542-1H Wireless LAN Connecting Adapter Installation Manual Wireless LAN Connecting Adapter Installation Manual Homepage: http://www.onlinecontroller.daikineurope.com For details
Spetec Laminar Flow Systems. Operating Instructions
Spetec Laminar Flow Systems Operating Instructions 1 Spetec Laminar Flow Systems Operating Instructions Thank you for your trust in the Spetec clean room systems! Your chosen system is ideally suited for
Rousseau 10. User Guide
Rousseau 10 User Guide Base station overview ➀ LED signals White, permanent light: - Base station ready, you can register a handset Slow flashing white light: - Paging call in progress - Active call (you
INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS ELECTRIC HEATING UNITS MODEL: ETA / EKI
INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS ELECTRIC HEATING UNITS MODEL: ETA / EKI Page 2 / 16 CONTENTS 1 GENERAL... 3 2 SAFETY... 3 2.1 Safety instructions... 3 2.2 Correct use... 3 3 DESCRIPTION
Service manual. Website: www.andico.com.au CAUTION - BEFORE SERVICING THE UNIT, READ THE SAFETY - PRECAUTIONS IN THIS MANUAL.
Website: www.andico.com.au Service manual CAUTION - BEFORE SERVICING THE UNIT, READ THE SAFETY - PRECAUTIONS IN THIS MANUAL. - ONLY FOR AUTHORISED SERVICE PERSONNEL. MODELS: MPK1-09CR-QB8 MPK1-12ER-QB6
Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CCS. Voltage rating: 115V~60Hz Power rating : 1400W
Portable Air Conditioner OWNER S MANUAL Read these instructions before use Model: MM14CCS Customer Support : 1-800-474-2147 Voltage rating: 115V~60Hz Power rating : 1400W For product inquiries or support
GNOME PELLET E.I. Pellet Heater Owner's Manual Installation and Operating Instructions. Please read this entire manual before installation.
Pellet Heater Owner's Manual Installation and Operating Instructions Please read this entire manual before installation. Save these instructions. SAFETY NOTICE HEATER MUST BE PROPERLY INSTALLED AND MAINTAINED
NewAir AC-10100E / AC-10100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS
NewAir AC-10100E / AC-10100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS ELECTRICAL SAFETY This appliance is for indoor use only. Always turn off the unit and unplug
MFU200 Integrated Under Counter Larder Fridge
MFU200 Integrated Under Counter Larder Fridge Manual for Installation, Use and Maintenance 1 Customer Care Department The Group Ltd. Harby Road Langar Nottinghamshire NG13 9HY T : 01949 862 012 F : 01949
Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MN12CES / MN10CESWW
Portable Air Conditioner OWNER S MANUAL Read these instructions before use 8 Model: MN12CES / MN10CESWW Voltage rating: 120V~60Hz Power rating : 1100W (MN12CES) Power rating : 900W (MN10CESWW) Customer
REB 1 REB 3 REB 5 REB 6 REB 8 REB 10 REB 12 REB 16
REB 1 REB 3 REB 5 REB 6 REB 8 REB 10 REB 12 REB 16 Manually Operated Electronic Speed Controller Single Phase For all applications using suitably specified single-phase induction motor fans 1 GENERAL The
HEAT RECOVERY VENTILATORS MODELS 90H-V ECM HRV, 90H-V+, 60H-V+ AND ENERGY RECOVERY VENTILATOR MODEL 90H-V ECM ERV
USER GUIDE HEAT RECOVERY VENTILATORS MODELS 90H-V ECM HRV, 90H-V+, 60H-V+ AND ENERGY RECOVERY VENTILATOR MODEL 90H-V ECM ERV PLEASE READ AND SAVE THESE INSTRUCTIONS These products earned the ENERGY STAR
USER S MANUAL FH052EAV1 FH070EAV1. System Air Conditioner (Cooling and Heating) ENGLISH ESPAÑOL FRANÇAIS ITALIANO PORTUGUÊS DEUTSCH E HNIKA
USER S MANUAL FH052EAV1 FH070EAV1 E HNIKA PORTUGUÊS ENGLISH ESPAÑOL ITALIANO DEUTSCH FRANÇAIS System Air Conditioner (Cooling and Heating) E S F I P D G DB98-29263A(1) Safety Precautions Register your
WALL MOUNTED SPLIT TYPE AIR CONDITIONER
WALL MOUNTED SPLIT TYPE AIR CONDITIONER MANUAL 8 OM-G12-ACSON CONTENTS - Operating Guide page 1 - G12 Remote Controller Indication page 2 - Indicator Lights page 4 - Installation of Aroma page 5 - Auto
ENGLISH INSTRUCTION & INSTALLATION MANUAL DUCTLESS MINI SPLIT AIR CONDITIONING SYSTEMS
ENGLISH INSTRUCTION & INSTALLATION MANUAL DUCTLESS MINI SPLIT AIR CONDITIONING SYSTEMS Céliera Corporation. All rights reserved. Unauthorized duplication, reproduction prohibited. CONTENTS SAFETY PRECAUTIONS...
Installation, operation and maintenance manual TX 35A
Installation, operation and maintenance manual TX 35A Rev.10 may 2012 Page 1 of 18 1.0.0 Table of contents INSTALLATION, OPERATION AND MAINTENANCE MANUAL...1 1.0.0 TABLE OF CONTENTS...2 2.0.0 ILLUSTRATIONS...2
Roof Top Air Conditioner INSTALLATION AND OPERATING INSTRUCTIONS
Roof Top Air Conditioner INSTALLATION AND OPERATING INSTRUCTIONS Ducted System RECORD THIS UNIT INFORMATION FOR FUTURE REFERENCE: Model Number: Serial Number: Date Purchased: This manual must be read and
Table of Contents. 1 - Specifications...3. 2 - Installation...3. 3 - Wiring...5. 4 - User controls...7
THERMOSTATS Table of Contents Page 1 - Specifications...3 1.1 - Product range...3 ARTTH001 (DSL-610)...3 ARTTH002 (DSL-700)...3 ARTTH003 (DSL-600)...3 1.2 - Technical data...3 1.3 - Power failures...3
COMPUTHERM Q7 Programmable, digital room thermostat. Operating Instructions
COMPUTHERM Q7 Programmable, digital room thermostat Operating Instructions GENERAL DESCRIPTION OF THE THERMOSTAT The COMPUTHERM Q7 type switched-mode room thermostat is suitable to regulate the overwhelming
User's Manual. Metapace L-1. Label Printer Rev. 1.00
User's Manual Label Printer Rev. 1.00 Table of Contents Manual Information & Usage Precautions 3 1. Content Confirmation 6 2. Product Part Names 7 3. Installation & Usage 9 3-1 Power Connection 9 3-2 Interface
Ingenico. User Guide 5100M. Secure transaction and payment solutions
User Guide Ingenico 5100M Secure transaction and payment solutions Ingenico 5100 M Contents 1 Presentation... 5 1.1 Overview of Ingenico 5100... 6 1.2 Keyboard details and functionality... 7 2 Use...
SunMaxx Solar Filling Station Operating Instructions
SunMaxx Solar Filling Operating Instructions Content 1. Declaration of conformity... 2 2. Introduction... 2 3. Transportation and unpacking... 4 4. Mounting and commissioning... 5 5. End of operation...
Operating Manual Remote Cost Control Monitor
Operating Manual Remote Cost Control Monitor INTRODUCTION: Congratulations on purchasing the Remote Cost Control. This is a state-of-the-art power monitoring socket that is highly accurate and easy to
For installation guide see reverse of book
USERS GUIDE LOGIC Combi 24, 30, 35 For installation guide see reverse of book When replacing any part on this appliance, use only spare parts that you can be assured conform to the safety and performance
OPERATION MANUAL. Total Heat Exchanger HRV (Heat Reclaim Ventilation) (Ceiling mounted duct type)
OPERATION MANUAL (Ceiling mounted duct type) VAM50FB VAM500FB VAM650FB VAM800FB VAM000FB VAM500FB VAM000FB 8 7 6 9 5 7 5 0 6 8 6 9 0 5 5 7 7 6 7 A A B B 5 6 5 6 7 VAM50F VAM800F VAM500F VAM500F VAM000F
Air Conditioner Water Heater - A Product of HotSpot Energy LLC
Air Conditioner Water Heater - A Product of HotSpot Energy LLC PLEASE READ THIS BEFORE YOU INSTALL THE UNIT 1. This air conditioner must be installed and/or repaired by a qualified technician. If you perform
Light Source User Guide
Light Source User Guide Compact DMX Light Source Models covered by this manual: UFO 150 CDMXG Glass, DMX - 240V UFO 150 CDMXP Plastic, DMX - 240V Universal Fibre Optics Issue 2 Revised: 23092013 Universal
OWNER S MANUAL. Permolock C3. Docking system for Power wheelchair in vehicle
OWNER S MANUAL US Permolock C3 Docking system for Power wheelchair in vehicle How to contact Permobil Head Office of the Permobil group Permolock C3 Docking system for electric wheelchair in vehicle Produced
MULTI XS 3600. Battery charger. For lead-acid batteries 1,2-120Ah
MULTI XS 3600 Battery charger For lead-acid batteries 1,2-120Ah User s Manual and a guide to professional battery charging For Starter/Deep Cycle batteries EN INTRODUCTION Congratulations on your purchase
EPM3. Phase Sequence and Motor Rotation Tester. Users Manual
EPM3 Phase Sequence and Motor Rotation Tester Users Manual 1 L1 L2 L3 2 3 A B C CAT 600V 3-PHASE TESTER 5 TEST M1 M2 BATT M3 EPM3 MOTOR ROTATION TESTER EPM3 MOTOR ROTATION DETERMINED WHILE FACING MOTOR
Uninterruptible Power Supply ERA LED 1.5 ERA LED 2.0 ERA LED 2.6. User s manual
Uninterruptible Power Supply ERA LED 1.5 ERA LED 2.0 ERA LED 2.6 User s manual Index Safety Warnings... 2 1 Introduction... 3 2 General Characteristics... 4 3 Receipt and site selection... 4 4 EXTERNAL
aseries A13B Mini Bullet Camera User Manual
aseries A13B Mini Bullet Camera User Manual Thank you for purchasing our product. If there are any questions, or requests, please do not hesitate to contact the dealer. This manual applies to the MicroView
GENANO 4500 MEDICAL AIR PURIFICATION DEVICE
GENANO AIR PURIFICATION TECHNOLOGY GENANO 4500 MEDICAL AIR PURIFICATION DEVICE OPERATING INSTRUCTION 1 GENANO LTD Kimmeltie 3 FI- 02110 Espoo, Finland Tel + 358 9 7743 870 Fax + 358 9 7533 130 www.genano.fi
Use and Care Manual. Model CPA12KH AIR CONDITIONER
Use and Care Manual Model CPA12KH AIR CONDITIONER Introduction Thank you for choosing this air conditioner to provide you and your family with all of the "Home Comfort" requirements for your home, cottage
USER MANUAL HRV CONSTRUCTO 2.0ES* HRV CONSTRUCTO 1.5ES* * THESE PRODUCTS EARNED THE ENERGY STAR BY MEETING STRICT ENERGY EFFICIENCY
USER MANUAL RESIDENTIAL USE ONLY VB0175 HRV CONSTRUCTO 2.0ES* HRV CONSTRUCTO 1.5ES* * THESE PRODUCTS EARNED THE ENERGY STAR BY MEETING STRICT ENERGY EFFICIENCY GUIDELINES SET BY NATURAL RESOURCES CANADA
ELECTRONIC THERMOSTAT AND THERMOMETER With SPEED CONTROL
148 OLD CONCORD TURNPIKE, BARRINGTON NH 03825 USA TEL (603) 868-5720 FAX (603) 868-1040 1-800-435-6708 E-Mail:[email protected] www.seafrost.com ELECTRONIC THERMOSTAT AND THERMOMETER With SPEED CONTROL
ECOCIAT. Domestic hot water heat recovery unit
Heat recovery unit Domestic hot water High energy efficiency with R410A Compact and quiet Scroll compressors Brazed-plate heat exchangers Heating Heat recovery ENVIRONMENTALLY HFC R410A PROTECTION DE FRIENDLY
OWNERS MANUAL. PAC 210 U Portable Windowless Air-Conditioner
OWNERS MANUAL PAC 210 U Portable Windowless Air-Conditioner 1 IMPORTANT INFORMATION When using electrical appliances, basic safety precautions should always be followed, including the following: - Read
USER S, MAINTENANCE and SERVICE INFORMATION MANUAL
CONTENTS SAFETY INFORMATION................ 2 FOR YOUR SAFETY....................... 2 SYSTEM OPERATION.................. 2 THERMOSTATS........................... 2 INTERMITTENT IGNITION DEVICE...........
USER S MANUAL HSC-24A
AIRREX AIR CONDITIONER USER S MANUAL HSC-24A Thank you for purchasing an AIRREX AIR CONDITIONER. BEFORE operation please read this user s manual carefully. Keep this manual readily available. It is ESSENTIAL
Stove Guard Kit User Manual
Stove Guard Kit User Manual Innohome improves the Safety of your Home. inno home www.innohome.com Stove Guard Kit User Manual Stove Guard Kit User Manual Congratulations! You now own one of the most intelligent
RDJ10RF/SET. Wireless room temperature controller with 24-hour time switch and LCD. Programmable, for heating systems
3 072 RDJ10RF RCR10/433 Wireless room temperature controller with 24-hour time switch and LCD Programmable, for heating systems RDJ10RF/SET Operating modes: Automatic, Comfort, Energy Saving, and Frost
RRV934. Multi-controller. Synco living
s 2 709 Synco living Multi-controller RRV934 RF-based multi-controller For precontrol of up to 2 room groups For control of ventilation plant with up to 3 stages RF communication based on KNX standard
3 IN 1 BATHROOM HEATER
3 IN 1 BATHROOM HEATER MODEL NO.: A515 - SH MINI FUNCTION: HEATER, EXHAUST FAN AND LIGHT Dear customers, Thank you for selecting the AUPU 3 in 1 Bathroom Heater. Please read all instructions before commencing
User s Guide. Oreck Air Purifier with HEPA Filtration. Important! Read this manual carefully, and keep for future reference.
User s Guide Oreck Air Purifier with HEPA Filtration Important! Read this manual carefully, and keep for future reference. Enjoy Congratulations on your purchase of the Oreck Air Purifier with HEPA Filtration.
IMPORTANT SAFETY INSTRUCTIONS WARNING READ AND SAVE THESE OPERATING AND SAFETY INSTRUCTIONS BEFORE USING THIS HEATER.
THERMAWAVE CERAMIC HEATER Model HZ-850 Series Model HZ-860 Series IMPORTANT SAFETY INSTRUCTIONS WARNING READ AND SAVE THESE OPERATING AND SAFETY INSTRUCTIONS BEFORE USING THIS HEATER. Warning Failure to
Operating Instructions Bedienungsanleitung Mode d emploi
Operating Instructions Bedienungsanleitung Mode d emploi DW 400 www.bron-kobold.com Operating instructions DW 400 Before use Please read all the information contained in these operating instructions carefully.
HCR3.2/.. Chipcard reader HOTEL SOLUTION
s 6 332 HOTEL SOLUTION Chipcard reader HCR3.2/.. Chipcard reader for hotel room access control Reads access code on chipcard Transfers access code to room controller Built-in optical display of messages
LS1024B / LS2024B/ LS3024B. Solar Charge Controller USER MANUAL
EPSOLAR LS1024B / LS2024B/ LS3024B Solar Charge Controller USER MANUAL Thank you very much for selecting our product! This manual offers important information and suggestions with respect to installation,
Manual. Solar Fountain Mobile Phone Charger
EN Manual Solar Fountain Mobile Phone Charger Copyrights 2008 Victron Energy B.V. All Rights Reserved This publication or parts thereof may not be reproduced in any form, by any method, for any purpose.
Operating Instructions Split System Air Conditioner
Operating Instructions Split System Air Conditioner Model No. Indoor Unit Type Indoor Unit Type Nominal Capacity 26 36 F2 Low Silhouette Ducted S-26PF2U6 S-36PF2U6 Connectable outdoor unit lineup This
SIBIR MANUAL V110 KE. English page 5 RKE - 1D 822 70 66-02
SIBIR MANUAL RKE - 1D V110 KE English page 5 822 70 66-02 2 1 A. Flue tube E. Adapter I. Thermostat B. Flue baffle F. Burner base J. Lever arm C. Control knob G. Lamp glass D. Fuel gauge H. Lamp glass
Si10-417_C. Pocket Manual. Service Diagnosis SPLIT & MULTI
Pocket Manual Service Diagnosis SPLIT & MULTI Service Diagnosis SPLIT & MULTI 1. Troubleshooting with LED...5 1.1 Indoor Unit... 5 1.2 Outdoor Unit... 10 2. Troubleshooting by Symptoms...11 2.1 Air conditioner
MOUNTING AND OPERATING INSTRUCTIONS
MOUNTING AND OPERATING INSTRUCTIONS CF 51/55 1. Delivery CF 51/55-1 calculator with battery (optionally with mains power supply) - 1 wall mounting bracket - package with material for sealing, screws, wall
Please read this owner s Manual carefully before operating the unit. - Cooling - Heating - Dehumidifying - Fan
Please read this owner s Manual carefully before operating the unit. - Cooling - Heating - Dehumidifying - Fan TABLE OF CONTENTS INTRODUCTION 2 IMPORTANT SAFEGUARDS...2 PACKAGE CONTAINS..2 NAMES OF PARTS.3
BLACK TIE. Instructions Manual
BLACK TIE EN Instructions Manual RECOMMENDATIONS AND SUGGESTIONS The Instructions for Use apply to several versions of this appliance. Accordingly, you may find descriptions of individual features that
Operating instructions
ebm-papst Mulfingen GmbH & Co. KG Bachmühle D-74673 Mulfingen Phone +49 (0) 7938 81-0 Fax +49 (0) 7938 81-110 [email protected] www.ebmpapst.com CONTENTS 1. SAFETY REGULATIONS AND S 1.1 Levels of hazard
EPSOLAR LS0512R / LS0524R. Solar Light Controller INSTRUCTION MANUAL. Please read this manual carefully before using the product!
EPSOLAR LS0512R / LS0524R Solar Light Controller INSTRUCTION MANUAL Please read this manual carefully before using the product! LandStar LS0512R / LS0524R Solar Light Controller Nominal system voltage
Hot Water Urns. all models. Helpline. v3.0
Hot Water Urns all models Helpline 01384 573999 instructions.indd 1 v3.0 02/06/2014 14:50 IMPORTANT INFORMATION - RETAIN FOR FUTURE USE When using any electrical appliance, basic safety precautions should