Eclipse EGA4 Combustion Analyzer

Similar documents
Highly efficient flue gas analyzer

LANCOM4 PORTABLE FLUE GAS MONITORING. NO NO2 NOx CO2 H2S SO2 CxHy. CO low CO high O 2 QUALITY CUSTOMER SOLUTIONS

The testo 340 What makes it The Ultimate Combustion Tuner?

Lightweight, compact, ergonomic, safe POLARIS FID. Portable TOC Analyser for Stack Emissions

Measurement Solutions for Refrigeration Technology.

Multifunction HVAC and IAQ Meter

Online Infrared Flue Gas Analyzer Gasboard 3000

PortaSens ll G AS DETECTOR

USB-500 Series Stand-Alone, Low-Cost Data Loggers

Hand-held thermometer Model CTH7000

LLB-OCMFM 2000 PORTABLE DOPPLER AREA-VELOCITY FLOWMETER

1/11 CO2 DOSAGE SYSTEMS. CO2 dosage system consists of following parts;

Software Features of Auto Gas Gas Analyzer Features HC, CO, CO2, Lambda, Air Fuel, NOx. Has optional RPM and Oil Temp.

USB-500/600 Series Low-Cost Data Loggers and Accessories

CO Low CO High O 2 NO NO 2 NOx SO 2 H 2 S CxHy CO 2 LANCOM III

Melting Point Apparatus

Visions become real. Temperature control and cooling systems. The innovative and reliable solution

DM70 Hand-Held Dewpoint Meter for Spot-Checking Applications

How To Use An Irius Pid Detector

DPI 610/615 Series. Druck Portable. Pressure Calibrators. GE Sensing. Features. Setting the Standard for Portable. Pressure Calibrators

API Marine. BMS Presentation. Ballast Measurement Systems

Loc-1Tx/Loc-5Tx/Loc-10Tx Data Sheet V3.3

USB-500 Series Low-Cost Data Loggers and Accessories

Freezers - Ultrafreezers. Platilab & Irilab Series

Data Logging Solutions from Lascar Electronics

USB-500/600 Series Low-Cost Data Loggers and Accessories

Vacuum drying oven for non-flammable solvents

OT 40L / 90L. Laboratory Steam Sterilizers

heat treatment equipment & accessories

Typical Aluminum GFM Mass Flow Meter

Environmental Equipment, Inc. IMR 5000 Continuous Flue Gas Monitoring System IMR 5000

Test equipment for temperature and its reduction

ARES II ADVANCED MULTI - CHANNEL AUTOMATIC RESISTIVITY & IP SYSTEM

TMS TANK MANAGEMENT SYSTEM

Car and commercial cial air conditioning service solutions

Digital pressure gauge for industrial applications Model DG-10-S, Standard version Model DG-10-E, Enhanced version

SHARKY 775 COMPACT ENERGY METER ULTRASONIC

How is Dew Point Measured Reliably?

MTI10 Insertion and MTL10 In-line Thermal Mass Flowmeter and Temperature Transmitter

Galvanic Parts Per Million Dissolved Oxygen Systems

Instruction Manual Dräger MSI ALV

PAT Tester Printers and Barcode Scanners

ACE. Automated Soil CO 2 Exchange System. Soil flux: an important component of total carbon budget

Dräger Alcotest 9510 Evidential Alcohol Measuring Device

450TOC Analyzer. Portable, Real-time, Continuous Total Organic Carbon Measurement. 450TOC Analyzer

Measuring Instruments for Flue Gas and Emissions

Hygro-Thermometer + InfraRed Thermometer Model RH101

Gas Custody Transfer Calibration

Digital inductive conductivity transmitter

KNC Model 3666 Automatic Pressure Calibration System

User Guide. Temperature and Humidity Datalogger. Model 42280

Measuring electric and magnetic fields

VDL 53 - Vacuum drying oven for flammable solvents

Portable digital microprocessor thermometers with interchangeable probes

ARES AUTOMATIC RESISTIVITY & IP SYSTEM. 850 W V p-p - 5 A Transmitter for all Multi-Electrode and Manual Modes Up to 10 Adjustable IP Windows

Residual Gas Analyzers

EASIDEW PORTABLE HYGROMETER INSTALLATION, OPERATION AND MAINTENANCE MANUAL

Continuous Monitoring of Flue and Combustible or Hazardous Gases and Vapors

PRODUCT PROFILE FEATURES

4-Channel Thermometer / Datalogger

Material test chamber with mechanical convection

Medical Air Systems: Scroll

Automated Test System SIMPLICITY COUNTS MSA s New GALAXY GX2 Automated Test System / Advanced Safety Management Effortless Operation

InfplusWin OPERATING MANUAL

Weighing terminals IP69K GMP EHEDG NSF. Precision in stainless steel Easy to clean perfect hygiene

GasAlertMax XT II H 2 O 2 LEL

Application Requirement

STERILIZERS, LABORATORY DRYING OVENS

ELECTROCHEMISTRY. BOECO ELECTRODES The electrodes are not included with the ph meters and have to be ordered separately:

BB-18 Black Body High Vacuum System Technical Description

Galaxy Gas Analyzer. New Brunswick. Operating manual

EuroFID Total Hydrocarbon Analyzer. Precise Determination of Total Hydrocarbons in Air for Corrosive as well as Condensing Gases

The PACE5000 Modular Pressure Controller/Indicator

SNMP Web Management. User s Manual For SNMP Web Card/Box

Technical Specification. Generating Set with Waukesha engine burning natural gas

data sheet DONATELLO Rev. I emiss - 25/10/ PRO03 code Automatic tissue processor DONATELLO

rigel 288 Electrical Medical Safety Analyser Key Features Applications

Wide Range InfraRed (IR) Thermometer with Type K input and Laser Pointer

G100 Range. Operating Manual

Nardalert S3 Non-Ionizing Radiation Monitor

CONTAMINATION CONTROL FOR ELECTRONIC AND SEMICONDUCTOR APPLICATIONS

DM Series CONTENTS. 1. Features Applications General Calibration Dimensions Specifications Calibration procedure 7

ThermoSorb Desiccant Dryers

Emission Testers. for Diesel, Gasoline and Gas Engines. Model: MET 6.3 MET 6.1 MET 6.2 Export MDO2 LON MGT5 DITEST SPEED 2000 RPM VC2

RUSKA PRODUCTS - PRICE LIST

KANE9206. Quintox Flue Gas Analyser. Stock No: November Kane International Ltd

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

Ultrasonic Load Monitoring

Computer Controlled Vortex Tube Refrigerator Unit, with SCADA TPVC

TAS ITA. DA1, dual csatlakozásfor thermostat. For control of 2 heaters on 1 thermostat. * * * * * * * * Thermostat for CH 12/18

Dual Laser InfraRed (IR) Thermometer with Color Alert

EUROPE S LARGEST SELECTION OF TEST & MEASUREMENT EQUIPMENT FOR HIRE INLEC.COM. Nationwide Low Call

How To Use A Detector 2

Battery Powered Thermal Mass Flow Meters for Gases

NoiseMeters. dosebadge. Monitoring Personal Noise Exposure

IFC 070 Technical Datasheet

Ron 3025 Crane Scale with 1"/25mm Display

MZ Series Overview. Introduction. (MZ 220 Illustrated)

Instruction Manual. T3111 T3111L T3111P T3111Ex

Transcription:

Data 924-2 1/25/08 Eclipse EGA4 Combustion Analyzer Providing the latest technologically advanced instrumentation for combustion service engineers, installers & technicians Features Complete sample-conditioning probe assembly Four robust electrochemical sensor cells for accurate emission measurements Automatic CO auto-range and sensor protection Built-in impact printer Rechargeable battery Easy to use, common-language text and keyboard Stores up to 250 samples Protective carrying case to store instrument, probe, charger and other accessories One Instrument, Many Functions 1. Combustion gas analyzer 2. Draft & differential pressure meter 3. Two-channel thermometer 4. Ambient CO monitor 5. Gas velocity with Pitot tube 6. Gas pipe and valve system leak tester 7. Gas leak location detector 9. Stores your smoke index measurement The new handheld EGA4 is the most comprehensive analyzer available for: Combustion tuning and maintenance; Water, air, surface temperature measurements;

Description of Features Gas Sensors EGA4 uses long life, low maintenance sensors. The operator can set alarm levels with audible buzzer on gas measurements. CO Auto-ranging and protection A dilution pump allows for automatic ranging for CO measurements from 0 to 100,000 ppm. This feature protects the CO sensor from exposure to high concentrations of CO. Rechargeable battery operations charger is supplied as standard. Either batteries or the Keyboard & Display icons), for simple and intuitive operations. Engineering units are selectable for US and European standards. or in bar graph format. Multi Fuel selection EGA4 allows selection of up to 10 fuels for calculating parameters can be loaded using optional PC software. Built-in impact printer A built-in rugged impact printer uses a common low cost roll of paper. The result is a more readable, longer life and heat resistant record than thermal printouts on chemical paper. Pressure/Draft input delta-pressure, pressure in combustion chamber, DP on Smoke index The results of using an optional external hand pump for smoke index measurement can be stored and printed on the report. Gas sampling probe The sampling probe is connected to the instrument with a dual hose through a water trap and a suspended Water trap from entering and damaging the instrument and Combustion air temperature sensor An optional Pt100 probe can measure remote combustion air temperature. Ambient monitoring An external optional probe is available for continuous operator with both acoustic and visual alarms. Gas pipe leak test program can check gas valves and pipes for the presence of leaks. Gas leak sniffer An external optional probe is available to locate the An external optional probe checks the ionization current Gas velocity An external Pitot tube connected to the differential parameter. Flash memory upgrading product performance. Standard Report of Calibration against traceable standards and shipped with a Report of Calibration. 2 Eclipse Model EGA4, v1.00 Data 924-2 1/25/08

EGA4 includes the basic measuring instrument with O2, CO, NO and NO 2 cells, gas sample probe with temperature and draft measurement, printer, differential pressure sensor, USB port, rigid plastic carrying case, battery charger, instruction manual, and calibration certificate. EGA4-1 is a 3-cell version, similar to the EGA4 except the NO2 cell is not installed. The total NOx will be calculated instead of directly measured. EGA4-2 similar to the EGA4 except the NO2 cell is replaced with a SO2 cell for measuring sulfur dioxide produced by fuel oil and coal combustion. Accessories Item Description 10002732 Printer paper roll, 18m (60'). 10002734 Printer ribbon. 10002729 Kit, water trap with air filter and connector. 10002711 Kit, filter cartridge. 10002725 Kit, rubber plug for water trap. 10002730 O-ring, analyzer, pneumatic connector 10002740 Probe, analyzer, 300mm (12in.) pistol grip, gas and draft, dual hose, 800 C max 10002741 Probe, analyzer, 750mm (30in.) pistol grip, gas and draft, dual hose, 1000 C max 10002746 Probe, remote air sensor with 2 meter cable length. 10002748 Probe, remote air sensor with 5 meter cable length. 10002736 Probe, ambient CO. 10002744 Probe, external flame ionization current. 10002745 Probe, natural gas (sniffer). 13160 Kit, smoke measurement index with pump, chart, filter paper 13157 Kit, filter paper for smoke measurement, 40 strips 13155 Scale, smoke index comparison chart 10002687 Case, analyzer,abs rigid plastic (instrument+probe+accessories) 10002688 Case, analyzer, aluminum (instrument+probe+accessories) 10002689 Case, analyzer, vinyl with shoulder strap (instrument+probe+accessories) 10002731 Holster, Rubber with Magnet 10002695 Cell, EGA analyzers, O2 autocalibrated 10002672 Software, flue-gas analyzer, PC configuration and data storage. For Units Prior To S/N 90056 10002684 10002676 10002673 10002674 10002675 10002677 Item For Units S/N 90056 to 128469 10002683 10002681 10002678 10002679 10002680 10002682 Accessories Continued Power Modules For Units S/N 128470 And Later 10030804 10030805 10030806 10030807 10030808 10030809 Description Module, power, 12Vdc automotive plug battery charger. Module, power, 115V 50/60 Hz USA plug. Module, power, 230V 50/60 Hz European plug. Module, power, 230V 50/60 Hz Schuko plug. Module, power, 230V 50/60 Hz UK plug. Module, power, 100V 50/60 Hz USA/Japan plug. Eclipse Model EGA4, v1.00 Data 924-2 1/25/08 3

Specifications Type: palm-top combustion gas analyzer for 4 gas sensors. Calibration: automatic calibration procedure at instrument switch-on. Self-diagnosis: Sensors efficiency test with display of diagnostic messages. Fuel types: Up to 10 selectable from keyboard. Flue gas probes: stainless steel shaft with incorporated temperature sensor. Display: 40x58 mm graphic LCD with backlight device. Memory: up to 250 full analysis data structured by locations (Tags). Power supply: High capacity Ni-MH rechargeable battery pack / external battery charger. Charging time: 8h at 90% with instrument off. Battery life: 6 hours (typical) continuous use (without printing and backlight). Printer: Internal impact type 24 columns with 58 mm paper roll (18 meters long). Printer power supply: from the analyzer battery pack. Print capability: up to 40 reports with full battery (typical). Service and user information: 3 programmable lines. Printed report header: 4 programmable lines. PC communication : USB Cable Operating temperature: from -5 C to +45 C Storage temperature: from -20 to +60 C (3 months maximum at temperatures exceeding the operational limits). Dimensions: 115x90x330 mm Weight: 1.1 kg with battery and printer Accuracies Parameter Sensor Range Resolution Accuracy O2 Electrochemical 0-25% 0.1% ±0.1% vol CO (H2 compensated) Electrochemical 0-8000 ppm 1 ppm ±10 ppm <300 ppm ±4% rdg up to 2000 ppm ±10% rdg >2000 ppm CO Auto-Range Electrochemical (dilution) 8000-100,000 ppm 500ppm CO2 Calculated 0-99.9% 0.1% ±10% reading NO, Low Electrochemical 0 500 ppm 0.1ppm ± 2 ppm <40ppm ± 5% rdg up to 500 ppm NO2 Electrochemical 0-1000ppm 1ppm ± 5ppm <125ppm ±4%rdg up to 1000ppm NOx Calculated 0-5000ppm SO2 Electrochemical 0 4000 ppm 1ppm ± 5 ppm <125ppm ± 4% rdg up to 4000 ppm Tair Pt100-10 - 100 C 1 C ± (0.2% + 0.15 C) Tgas Tc K 0-1000 C 1 C ± (0.3% + 0.3 C) Differential Temp. Calculated 0-999 C 0.1 C Pressure/Draft Piezo ±100 hpa 0.01 Pa ± 3Pa <300 Pa ±40" w.c. 0.01" w.c. ± 1% rdg. >300 Pa Excess air Calculated 1.00 - infinity 0.01 Gas speed Calculated 0 99.9 m/s 0.1 m/s Efficiency Calculated 1-99.9% 0.1% All emission measurements can be displayed with reference to a programmable O2 value. NOx concentration can be shown in terms of stack equivalent NO2. Accuracy limits are stated as % of reading. An additional ±1 digit error has to be considered. The stated pressure relative accuracy is valid only after the zero procedure. Measuring display readings can be directly converted from ppm to mg/nm3. Measuring display readings can be directly converted from hpa to mmh2o, mbar, or inh2o. 924-2 Data 1/25/08 Litho in U.S.A.

Offered By: Power Equipment Company 2011 Williamsburg Road Richmond, Virginia 23231 Phone (804) 236-3800 Fax (804) 236-3882 www.peconet.com