Air rod. Air terminals and fixings. Air terminal base. Strike pad. Supplied with locknut.

Similar documents
NORTH ORANGE COUNTY COMMUNITY COLLEGE DISTRICT SECTION GROUNDING AND BONDING FOR COMMUNICATION SYSTEMS

TS 813 GROUNDING AND BONDING TTD TRAFFIC SIGNAL INSTALLATION AND CONTROLLER CABINET GROUNDING SYSTEM TTD CONTROLLER CABINET GROUNDING

This unit is a pump that will clear the waste from a domestic shower and washbasin, bath, washing machine, glass washer and a sink.

Rooflight INSTALLATION INSTRUCTIONS

Pipe threads for tubes and fittings where pressure-tight joints are not made on the threads. (requires PTFE sealing tape or liquid sealant).

Geberit Pluvia. Syphonic roof drainage system. Overview Page 42. Geberit Pluvia outlets 6 l. Geberit Pluvia outlets 14 l

3. Geberit Pluvia Roof Drainage Systems

DEHN + SÖHNE. DEHNconductor System No Problems with Proximities

SECTION 22 LIGHTNING PROTECTION SYSTEM

1. Description. 2. List of Accessories included A B C F G H

Installation guide for the SafeLine type anchorage device. Tested in compliance with EN 795: No.: SE-...

SECTION PIPE HANGERS AND SUPPORTS

Canopy Surge. User Manual

DESCRIPTION UNIT QTY RATE TOTAL (KSHS) Supply and install the following: -

METHOD STATEMENT FOR INSTALLATION OF CABLE TRAY/TRUNKING/LADDER

STATE BANK OF INDIA.

INSTALL/REMOVAL INSTRUCTIONS: WINDOW REGULATOR

GENERAL SPECIFICATION FOR CIVIL ENGINEERING WORKS SECTION 13 WORK FOR ELECTRICAL AND MECHANICAL INSTALLATIONS

Product Catalog. Lightning Protection UL Listed product range

800 Communications Circuits

PLUMBING MAINTENANCE WORK FOR TOILETS IN HEAD OFFICE, SUPPLYCO ESTIMATE

3. SEISCO PARTS & SERVICE REMOVAL AND REPAIR GUIDE

SPECIFICATIONS FOR TENDER NO: PSNR/SCP/VKS/E 1635 ANNEXURE I TECHNICAL SPECIFICATIONS FOR LIGHTING HIGH MAST

Technical data sheet PVC Bi-fold doors

TABLE OF CONTENT

EARTHING AND BONDING AT SECONDARY SUBSTATIONS

WELDING & CUTTING MAIN EQUIPMENT

SIMPLAIR PIPING TOOL

valid as of 1 April 2014 Intec injection hose system

INSTALL/REMOVAL INSTRUCTIONS: WINDOW REGULATOR

Now Available through:

Cable Runways & Accessories

FLEXIBLE COPPER & ALUMINIUM CONNECTIONS. Product Range 1 VGL - ALLIED CONNECTORS

Consultants Handbook

3M Mobile SkyWalk Series Horizontal Lifeline Product Return Form

Mechanical Services Standard Specification Compressed Air Systems. May For ROYAL HOLLOWAY UNIVERSITY OF LONDON

Memtec Single Ply PVC Membrane Roofing and Waterproofing Technology. Modern Efficient Performance Cost Effective Flat Roofing Systems

BILL OF QUANTITY FOR THE WORK OF "REPAIRING OF CIVIL & PLUMBING WORKS INSIDE AND OUTSIDE OF THE WORKSHOP"

STANDARD SPECIFICATION. for. Plumbing, Heating, Hot Water, Cold Water & Electrical work. Sussex Lodge London W2 & 16 Stanhope Terrace London W2

Removable Aluminium posts

Pad printing accessories

BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS

Syphonic Roof Drainage

TFSR & TFSK Roof Fans

ANTENNA PARTS CATALOG

Description. Outlets Page 62. Contact foil Page 65. Accessories Page 65. Outlets Page 68. Accessories Page 69. Brackets Page 73.

Embedded Parts Introduction - Anchors

Please also see 10 golden rules for correct Saniflo installation on

OUTDOOR DISCONNECTORS A division of ACTOM (Pty) Ltd

Shower and Floor Gullies Channel Drain and Tile Drain SECTION

GAS DISTRIBUTION PRODUCTS STEEL SERVICE TEES

FOR ANY QUESTIONS, PLEASE CALL M-F 8:00a.m.-8:00p.m. EST. REAR BRAKES 1 AEROSPACE COMPONENTS

SECTION HANGERS AND SUPPORTS FOR HVAC PIPING AND EQUIPMENT

Product Information 19 / 45HU Data-Center-Rack (Cabinet)

INSTALL/REMOVAL INSTRUCTIONS: WINDOW LIFT MOTOR

Pipe Clamps and Accessories

Electrical for Detached Garages: Updated Feb 19, 2016 for 2015 CE Code in force Jan. 1, Underground branch circuit feeding a detached garage:

TECHNISCHE FICHE - TECHNISCHE FICHE - Chat Board: Classic

Parts Manual. TWIN 2 & 3 Parts & Accessories F210846R01. Your efficiency is our Challenge!

UNIVERSAL MOUNTING SET (UMS) FOR ARTOLINK FSO EQUIPMENT

2014 NEC Guide Lines for Home Owner Doing Electrical Work on their Property

ScottishPower Distribution Cables & Equipment. Metal Theft

Roofing. Sarnafil S EL. Polymeric membrane for roof waterproofing. Product Description

CAST IRON THE BASICS. Heatline - Cast Iron Radiators SMOOTH FLAT FILE TO REMOVE ANY SWARF. ONE TIME. ASSEMBLY. JOINTS SHOULD BE TIGHTENED.

5.2. Overview. The better method to install solderless compression connectors on power cable

No Phone Line II-48 System

Introduction... 3 Setting the Combination... 4 Securing the DEFCON CL... 5 Locking the DEFCON CL to your Notebook Computer...

Corrosion Control & Cathodic Protection for Water & Wastewater Systems

INSTALLATION INSTRUCTIONS AIRCOMMAND IBIS ROOFTOP AIRCONDITIONER

CUSTOMER FLOW MANAGEMENT

INSTALL/REMOVAL INSTRUCTIONS: WINDOW REGULATOR

CATHODIC PROTECTION SYSTEM DESIGN

Fall Protection Solutions

ISSUE 08/08. KEEP INFORMED Look for other Good Idea Leaflets that could help you with your current project.

Isover HVAC Application Handbook Installing fire protection insulation to metal ductwork

SECTION CABLE TRAYS FOR COMMUNICATIONS SYSTEMS

Lake County EOC. Vendor Quotes for Lightning Protection

Preface nivtec.com 3

NEGRP TEST SUMMARY. Joseph A. Lanzoni, November 2005

INSTALLATION INSTRUCTIONS HUSTLER 4-BTV, 5-BTV TRAP VERTICAL WARNING INSTALLATION OF THIS PRODUCT NEAR POWER LINES IS DANGEROUS

Puddle Flange. FRANK Puddle Flange

172 Holesaws Overview Bosch Accessories for Power Tools 09/ Diamond holesaw. with Power-Change adapter. 190 Diamond drill bits

Saferand easierinstallation

Portable digital microprocessor thermometers with interchangeable probes

WIRE, TERMINAL AND CONNECTOR REPAIR CONDUCTORS

Linear modules Lifting units Rotary modules Grip modules Inductive proximity switches Plug connectors

INSTALLATION OF A BAY WINDOW

DYNA RIDER FOOTBOARD KIT

CONTENTS. Yale University Design Standards. Underground Electrical Duct Bank. A. Summary. B. System Design and Performance Requirements

IH E Sigma Island 90

GUIDELINES FOR INSTALLATION OF AIR CONDITIONING UNITS PHILLIP STREET, SYDNEY

I-Line. Accessories. Essential cable installation products for corrugated, smooth wall, and braided cables

TopSky DLG Installation Manual

UB1 AIR CONDITIONING UNIT INSTALLATION INSTRUCTIONS

Linkeo 19" freestanding cabinets

Premium Nixalite All Stainless Steel Bird Barrier Spikes Includes specifications for: Premium Nixalite Models S, H and W and Mounting Hardware.

BOQ for Plumbing, Sanitary Works

Fisher 1052 Size 20 Diaphragm Rotary Actuator with F and G Mounting Adaptation

PPS-PPQ-BT-PIAS RESIN INSULATORS FOR OIL INSULATED ELECTRICAL MACHINES

UNIVERSAL RAILING, STEEL

Transcription:

Air terminals and fixings Air rod Rod Rod Thread Material Weight Part no. length diameter diameter per rod 500mm 10mm 10mm Copper 0.33kg RA400-FU 1000mm 10mm 10mm Copper 0.65kg RA402 500mm 10mm 10mm Aluminium 0.11kg RA080 Supplied with locknut. Air terminal base Conductor Thread Conductor Weight Vertically Horizontally diameter diameter material mounted mounted 8 10 Copper 0.30kg SD307 SD305 8 10 Aluminium 0.11kg SD007 SD005 Recommended fixing - counter sunk woodscrew 1 1/2 x no.10 and wall plug. Strike pad Conductor Weight Part no. material Copper 0.41kg PL010 Aluminium 0.13kg PL005 Accessories Description Weight Part no. Copper stem for use 0.07kg SM010 with PL010 This product is supplied with a set screw to enable the lightning conductors to be attached to the strike pad.the strike pad PL010 can be used in lightning protection schemes in multi-storey car parks, using the stem SM010 connected to the re-bar cage or buried earth conductor. Solid circular system Lightning protection

One hole cable clip Conductor fixings diameter material 8mm Copper 0.01kg CP905 8mm Aluminium 0.01kg CP925 10mm* Copper 0.01kg CP915 10mm* Aluminium 0.01kg CP935 Recommended fixing - round head woodscrew 1 1/2 x no.10 and wall plug. * PVC covered 8mm conductor. Heavy duty cast cable saddle diameter material 8mm Copper 0.09kg CP805 8mm Aluminium 0.03kg CP806 10mm* Copper 0.10kg CP815 10mm* Aluminium 0.04kg CP816 * For use with pvc covered 8mm conductor or for supporting air terminals when used in conjunction with wall mounted air terminal base. Can also be used with glazing bar holdfast and back plate holdfast stem. Recommended fixing - counter sunk woodscrew 1 1/2 x no.10 and wall plug. Push-in plastic cable clip Conductor Weight Part no. Colour range diameter Black Grey Stone White Brown 8mm 0.01kg - CP872 - - CP887 10mm* 0.01kg CP861 CP871 CP876 CP881 CP886 Recommended fixing - counter sunk woodscrew 1 1/2 x no.10 and wall plug. * PVC covered 8mm conductor. Lightning protection Solid circular system

Conductor fixings Weldable push-in clip For use with PVC roofing only Conductor Colour Weight Part no. size 8mm Grey 0.03kg CW872 8mm Brown 0.03kg CW887 10mm* Grey 0.03kg CW871 10mm* Brown 0.03kg CW886 * PVC covered 8mm conductor. Accessories for weldable clips Description Weight Part no. Universal welding solvent 0.57kg CW905 500ml spray applicator (sufficient for the application of approximately 200 clips) For use with Furse weldable clips only. Description Weight Part no. Cleaning solution (Acetone) 0.62kg CW999 For cleaning lacquered SARNAFIL roofing membranes and other lacquered materials. 500ml spray applicator Please note: Solvent cannot be used outside the UK. For overseas projects, please contact Furse for advice. Adhesive push-in clip For use on surfaces other than PVC roofing Conductor Weight Part no. Colour range diameter Black Grey Stone White Brown 8 0.02 - CA872 - - CA887 10* 0.02 CA861 CA871 CA876 CA881 CA886 Description Weight Part no. Surface primer 0.24kg CA900 250ml spray applicator (sufficient for the application of approx. 500 clips) Note: Furse strongly recommend use of the primer when installing Furse adhesive clips. * PVC covered 8mm conductor. Solid circular system Lightning protection

Non metallic slate holdfast Conductor fixings Conductor Colour Weight Part no. diameter 8mm Brown 0.03kg HF176 8mm Grey 0.03kg HF191 Variations of tail length, clip size and clip colour can be made to order as special items. Pyramid holdfast Type Weight Part no. Filled 0.97kg HF975 Supplied filled with concrete, they can be used to hold conductors on flat surfaces.the lip around the base allows them to be built into bitumen type roofs, etc. Suitable for 8mm diameter bare conductor. Lightning protection Solid circular system

Test and junction clamps Square clamp diameter material 8mm Copper 0.17kg CS605 8mm Aluminium 0.07kg CS610 For forming cross or tee joints. Tee clamp diameter material 8mm Copper 0.17kg CS505 8mm Aluminium 0.07kg CS510 For forming tee joints. Jointing clamp diameter material 8mm Copper 0.17kg CS405 8mm Aluminium 0.08kg CS410 For forming straight through joints. Solid circular system Lightning protection

Test clamp Test and junction clamps diameter material 8mm Copper 0.20kg CN305 8mm Aluminium 0.09kg CN310 For forming straight through joints or for disconnection and test purposes. Also available for connecting 8mm diameter conductor to 25 x 3mm conductor. Bimetallic connector Conductor Weight Part. no. diameter 8mm diameter aluminium 0.25kg CN915 conductor to 8mm diameter copper conductor 8mm diameter aluminium 0.19kg CN920 conductor to 25mm x 3mm copper tape For joining aluminium and copper circular conductors. Particularly useful where an aluminium lightning protection system needs to be earthed using copper. Oxide inhibiting compound Plastic bottle 0.23kg (8oz) Part no. CM005 For all the items in this range we recommend the use of oxide inhibitor when aluminium fittings are installed. Oxide inhibitor is a non-water soluble, natural-petroleum based polymer grease that seals electrical connections from oxygen and moisture. Lightning protection Solid circular system

Bonds and clamps Metalwork bond diameter material 8mm Copper 0.37kg CS350 8mm Aluminium 0.17kg CS355 For connecting to all types of metal structures up to 13mm thickness. Pipe bond Conductor Pipe Conductor Weight Part no. diameter diameter material 8mm 50-200mm Copper 0.46kg BN175 8mm 50-200mm Aluminium 0.25kg BN176 For bonding to ducts and large diameter pipeworks. Re-bar clamp Conductor Pipe Conductor Weight Part no. diameter diameter material 8mm 8-18mm Copper 0.32kg BN150 8mm 18-38mm Copper 0.75kg BN155 For bonding to re-inforcing bars, steam pipes, handrails etc. Solid circular system Lightning protection

Tower earth clamp Bonds and clamps Conductor Channel Bolt size Conductor Weight Part no. diameter thickness material 8mm 10mm M10 Copper 0.08kg BN300-FU 8mm 10mm M10 Aluminium 0.05kg BN305 For bonding copper and aluminium conductors to steel work. Straight setscrew type cable socket Conductor Palm hole Conductor Weight Part no. diameter diameter material 8mm 12mm Copper 0.11kg SX450 8mm 12mm Aluminium 0.05kg SX455 Lightning protection Solid circular system