STATE BANK OF INDIA.
|
|
|
- Aubrie Wells
- 9 years ago
- Views:
Transcription
1 Page 1 of 5 B SANITARY, PLUMBING & DRAINAGE STATE BANK OF INDIA. PROPOSED RURAL SELF EMPLOYMENT TRAINING INSTITUTE AT RAIGARH IN C.G. DIRECTOR'S BUNGALOW SCHEDULE OF ITEMS-PLUMBING AND SANITARY WORK 1 Providing and fixing in position Chlorinated Polyvinyle Choride (CPVC) pipes concealed in the brick masonary walls by cutting chases using mechanical cutter, providing nails/clamps to hold the pipes in position and making the surface good in line and level. The pipes should have thermal stability for hot & cold water supply including providing required CPVC brass threaded fitings and specials such as 'Tees, Bends, angles, Elbows, reducers, unions etc and fixing the pipes with metal clamps at 1.0 m c/c, including joining the pipes as per manufacturers specifications using approved quality CPVC Solvent and testing the joints complete as per directed Wherever necessary hot water pipes to be suitably insulated to prevent heat transfer to wall tiles etc. a) 15 mm nominal outer diameter pipe Rmt Providing and fixing in position Chlorinated Polyvinyl Choride (CPVC) pipes externally having thermal stability for hot & cold water supply including all CPVC brass threaded fitings such as 'tees, bends, angles, reducers, unions etc and fixing the pipes on metal clamps away from the wall at 1.00 m c/c including joining the pipes as per manufacturers specification with one step CPVC Solvent /solvent cement and testing the joints complete as per directed, a) 25 mm nominal outer diameter pipe Rmt 20.00
2 Page 2 of 5 b) 32 mm nominal outer diameter pipe Rmt c) 50 mm nominal outer diameter pipe Rmt Providing and fixing in position CP Brass Bib Cock of approved quality and make, including all fittings and fixturers 4 Providing and fixing in position CP Brass Stop Cock of approved make and quality including all fittings and fixturers 5 Providing and fixing ISI marked gun metal valve with C.I. wheel of approved quality (screwed end) and make Nos a) 50mm nominal bore b) 32 mm nominal bore 6 Providing and fixing ISI marked non return valve of approved quality 7 Providing and fixing in position long neck Bib Cock for kitchen etc including all fittings and fixturers 8 Providing and fixing in position Wash Hand Basin, counter sunk of ivory colour of approx size 440 mm x 550mm including providing CP Brass Pillar Cock, Bottle Trap, Stop Cock, PVC Connection, Base Coupling etc. of approved quality and make. Rate to include suitable MS bracket including 40mm dia connection GI pipe upto nahani trap concealed in wall 9 Providing and fixing in position stainless steel kitchen sink of approved make of approx overall size 535 x 460 x 190 mm deep fixed to Kitchen platform, including providing CP brass, base coupling, bottle trap etc. of approved make and making suitable connection to nahani trap complete with 40mm dia GI pipe 'b class'
3 Page 3 of 5 10 Providing and fixing in position European WC pan of approved make and size including providing and fixing PVC Flushing Cistern of 12 liters capacity, PVC toilet seatcover including necessary fitings and fixturers viz. Flush pipe, CP brass stop cock, PVC connection etc 11 Providing and fixing in position Orissa pattern 'Indian' WC pan with 12 liters Low Level PVC flushing cistern etc including all necessary CP fittings, stop cock, PVC connections etc. 12 Providing and fixing in position PVC heavy duty 'nahani trap' including all connections to waste water line 13 Providing and fixing in position CP brass soap holder of approved make and quality including all fittings and fixturers 14 Providing and fixing in posiion CP brass hooks on doors etc including all fittings and fixturers 15 Proviidng and fixing in position CP Brass Jet spray with flexible pipe and necessary two way fitting of approved make including necessary fittings and fixturers 16 Providing and fixing in position heavy duty PVC down take pipes (4Kg pressue) of Prince, Supreme, Katsa or equivalant approved make including all acessories such as 'Y', 'angle junction', 'connectors', 'inspection joints' etc joining together water tight using approved adhessive and clamping it on wall with 'D' clamps Nos 3.00 a 100 mm dia Rmt b 65 mm dia Rmt 7.00
4 Page 4 of 5 17 Providing and constructing Inspection Chambers of approx size 450 x 900mm in one brick thick walls, including providing plaster 1:4 cement sand mix in single coat about 12mm and with heavy duty PVC cover including the frame as per sample approved. The rate should include necessary earthwork in excavation, disposal of surplus material as directed, laying P.C.C. 1:3:6, 100mm thic levelling course, making neat cement finish smooth benching, hunches, channels etc. in CC 1:2:4 complete for smooth flow as required. Rate to include for making connections to stone ware/pvc pipes of minimum 150 mm dia in the brick wall 18 Providing making Gully Trap of approx size 450 x 450 in one brick thick, and finishing it with 12mm thk 1:4 cement sand mix plaster, including providing P.C.C. benching and providing stone ware pipe connections, with approved quality CI/PVC cover with frame 19 Providing and laying heavy quality (Minimum 6 Kg pressure) PVC pipes for sewerage disposal system including necessary excavation, laying 100mm thick PCC 1:3:6 levelling base course with all fittings and specials testing of joints and concealing the Pipe in PCC 1:2:4 all around with minimum 100 mm thick concrete complete as directed at site. Nos 2.00 (a) 200 mm dia. Rmt (b) 150 mm dia. Rmt Providing and fixing PVC overhead tank required capacity as under including construction of 150mm high platform with concrete blocks/bricks/cc (finishing complete) and all connections (inlet & outlet) with necessary fittings and making them water tight
5 Page 5 of 5 PVC (1500 litres) Director's Bungalow Total of plumbing and sanitation (B) SIGNATURE OF THE CONTRACTOR NAME ADDRESS
BOQ for Plumbing, Sanitary Works
BOQ for Plumbing, Sanitary Works Page 1 of 6 Sr.No Item Description Quantity Unit Rate Amount (Rs.) 1 SANITARY FIXTURES Providing & Fixing star white colour vitreous china wall mounted wc with 1a heavy
PLUMBING MAINTENANCE WORK FOR TOILETS IN HEAD OFFICE, SUPPLYCO ESTIMATE
Sl.No. PLUMBING MAINTENANCE WORK FOR TOILETS IN HEAD OFFICE, SUPPLYCO ESTIMATE Description of item Qty Unit Rate Amount 1 Demolishing tile work/cement concrete/( carefully taking out the closet and other
SUMMARY (PLUMBING WORKS)
PROPOSED OBCRSETI BUILIDNG AT JASSOWAL, DEHRADUN, UTTRAKHAND SUMMARY (PLUMBING WORKS) SL. DESCRIPTION OF ITEMS PAGE REFE. AMOUNT (RS.) I PLUMBING WORKS 1.0 SH: SANITARY FIXTURES BOQ (P ) - - 2.0 SH: SOIL,
Toilet Plumbing. Here is a selection of different types of W.Cs and urinals. Can you match the pictures to the names below?
Toilet Plumbing. Here is a selection of different types of W.Cs and urinals. Can you match the pictures to the names below? J. H. I. A. European water closet B. Indian style W.C C. Urinal corner (to be
Tender schedule. Rate in
Name of work Maintanance work for hajj house at Karipur for the year 2012 Tender schedule Sl. No 1 1.00 Cubic Probable Quantity Description of work 2 8.00 Cubic 3 12.00 Cubic 4 7.00 Cubic Dismantling,
Revised Specifications & Scale of Amenities for General Pool Residential Accommodation (Type I to VI) Revised Amenities.doc
Revised Specifications & Scale of Amenities for General Pool Residential Accommodation (Type I to VI) 1 Specifications for Residential Buildings S Type I, II, III & Servant Qrs. Type IV Type V and VI Existing
Project : CONSTRUCTION OF BUILDING(including electrical and plumbing works) FOR NATIONAL CENTRE FOR SUSTAINABLE COASTAL MANAGEMENT,CHENNAI
Project : CONSTRUCTION OF BUILDING(including electrical and plumbing works) FOR NATIONAL CENTRE FOR SUSTAINABLE COASTAL MANAGEMENT,CHENNAI TENDER CLARIFICATIONS- no 3 dated 3rd Oct 13 issued in response
LONDON BOROUGH OF HACKNEY BUILDING SERVICES ENGINEER REPORT GAS HOUSE, SPRINGFIELD PARK, HACKNEY
LONDON BOROUGH OF HACKNEY BUILDING SERVICES ENGINEER REPORT GAS HOUSE, SPRINGFIELD PARK, HACKNEY 10 TH JUNE 2011 London Borough of Hackney Page 1 of 6 Brief Description of the Proposed Works The existing
BILL OF QUANTITY FOR THE WORK OF "REPAIRING OF CIVIL & PLUMBING WORKS INSIDE AND OUTSIDE OF THE WORKSHOP"
BILL OF QUANTITY FOR THE WORK OF "REPAIRING OF CIVIL & PLUMBING WORKS INSIDE AND OUTSIDE OF THE WORKSHOP" Sl. 1 DISMANTLING WORK 1.1 Stripping off worn out plaster (outside and inside) and raking out joints
CUBICLE SYSTEMS LTD. CI/SfB 74 X IPS. Pre-plumbed Wall Duct Access Panel System
CUBICLE SYSTEMS LTD CI/SfB 74 X IPS Pre-plumbed Wall Duct Access Panel System ISO 9001:2000 IPS the perfect washroom solution plumbing wall duct panel system and cubicles installed in one operation Cubicle
BUDGETARY COST ESTIMATE OF INTERIOR WORK OF LOWER PAREL BRANCH FOR CENTRAL BANK OF INDIA
BUDGETARY COST ESTIMATE OF INTERIOR WORK OF LOWER PAREL BRANCH FOR CENTRAL BANK OF INDIA No. Item Particular Qty. Unit Rate Amount Breaking 1 Removing existing flooring/ skt. / plaster / tile form wall
Sports Buildings: budget costs for the Flood Relief Fund
Sports Buildings: budget costs for the Flood Relief Fund The list below provides typical costs for flood insurance works, typically required by sports clubs or facilities. The list is not exhaustive but
Plumbing Installations. A homeowner guide to the City of Winnipeg plumbing requirements for a single-family dwelling
Plumbing Installations A homeowner guide to the City of Winnipeg plumbing requirements for a single-family dwelling February 2001 contents General Information 3 Inspection 4 New Drain and Vent Installations
SPECIFICATIONS FOR VASWANI BRENTWOOD PROJECT. RCC Framed Structure confirming with zone II seismic detailing. Reinforced Cement Concrete
SPECIFICATIONS FOR VASWANI BRENTWOOD PROJECT 1. CONSTRUCTION: Foundation Super Structure Internal Walls External Walls Roof Retaining Walls RCC footing RCC Framed Structure confirming with zone II seismic
CONSTRUCTION SUMMARY OF THE PEREIRA HOUSE AT MADOL, VERNA GOA.
CONSTRUCTION SUMMARY OF THE PEREIRA HOUSE AT MADOL, VERNA GOA. On our visit to the house of Conceicao Pereira s house we decided to make many changes that were needed to improve the living conditions of
Plumbing. Helpful Hints Residential Construction. Lincoln County. Bert Polk Plumbing Inspector
Plumbing Helpful Hints Residential Construction Bert Polk Plumbing Inspector Lincoln County 2015 Waste and vent fittings Vent 90 medium 90 long 90 1/16 bend,1/8 bend,1/6 bend, medium 90 san tee combination
SECTION V : TECHNICAL SPECIFICATIONS. B) Plumbing, Water Supply & Sprinkler system
Sabarmati River Front Development Corporation Limited Page: P - 1 SECTION V : TECHNICAL SPECIFICATIONS B) Plumbing, Water Supply & Sprinkler system Section 1 : General 1. WORKMANSHIP The workmanship shall
Close Coupled & Back To Wall WC Saintaryware. Fitting Instructions
Close Coupled & Back To Wall WC Saintaryware Fitting Instructions Before starting any installation project please consider the following: Prior to drilling into walls, check there are no hidden electrical
WASHROOM UPGRADE SIR CHARLES TUPPER BUILDING 2250 RIVERSIDE DRIVE, OTTAWA, ON SIR CHARLES TUPPER BUILDING A0.0 COVER SHEET / DRAWING LIST
0 RIVERSIDE DRIVE, OTTAWA, ON A0.0 COVER SHEET / DRAWING LIST A0. LEGEND AND GENERAL NOTES A0. GENERAL NOTES A0. GENERAL NOTES A0. TYPICAL WASHROOM WALL/SINK SECTION A0. DETAIL - CONTROL JOINT A0. DETAIL
ESTIMATE (CIVIL) BASED ON DSR 2013 NAME OF THE WORK :- A.R.M. CIVIL WORK OF E.S.I.C. SRO BUILDING AND RESIDENTIAL QUARTERS FOR THE YEAR
ESTIMATE (CIVIL) BASED ON DSR 2013 NAME OF THE WORK :- A.R.M. CIVIL WORK OF E.S.I.C. SRO BUILDING AND RESIDENTIAL QUARTERS FOR THE YEAR 2014-2015 Sr. No Description of item Qty. Estimated may be more or
Saferand easierinstallation
EN 85-07 Saferand easierinstallation IföSigninstallationsystem andifösignbuilt-incistern www.ifosanitar.com/sign Aneffectivesolution withmanyadvantages. Ifö Sign installation system makes life a little
SECTION 02150 REMOVAL OR ABANDONMENT OF EXISTING UTILITIES AND UNDERGROUND STRUCTURES. 1. Trench excavation, backfill, and compaction; Section 02250.
02150-1 of 6 SECTION 02150 REMOVAL OR ABANDONMENT OF EXISTING 02150.01 GENERAL A. Description Removal or abandonment of existing utilities and underground structures shall include, but not necessarily
Old people and nursing homes. Old people and nursing homes, rehab/medical. SPECIAL SOLUTIONS. Security and comfort for every stage of life.
nursing homes. SPECIAL SOLUTIONS. Security and comfort for every stage of life. 401 Model: Eurotrend Care wash basin EN 32, DIN 18024-2 and 18025-2 11-96 (, EN 14688) 1 without overflow, pre-punched tap-hole,
REGISTRATION EXAMINATION, NOVEMBER 2013 CERTIFYING PLUMBER ANSWER SCHEDULE
No. 9195 REGISTRATION EXAMINATION, NOVEMBER 2013 CERTIFYING PLUMBER ANSWER SCHEDULE Plumbers, Gasfitters and Drainlayers Board, 2013. All rights reserved. No part of this publication may be reproduced
08003-1 WATER SERVICE 2
08003_Mar08_2011.pdf Page 1 of 7 INDEX Page 08003-1 WATER SERVICE 2 1.1 Pipe 2 1.1.1 Copper 2 1.1.2 Polyethylene 2 1.2 Valves and Fittings 2 1.2.1 Main Stops 3 1.2.2 Curb Stops 3 1.2.3 Curb Box 3 1.2.4
Shower and Floor Gullies Channel Drain and Tile Drain SECTION
Shower and Floor Gullies Channel Drain and Tile Drain SECTION 2 Shower and Floor Gullies, Channel Drain and Tile Drain 29 General Information Shower and Floor Gullies McAlpine has responded to market conditions
LS 2540 SEWER LATERALS AND INSPECTION TEES
LS 2540 SEWER LATERALS AND INSPECTION TEES A. Summary B. Submittals C. Site Information D. Sewer Pipe and Fittings E. Lateral Locations F. Lateral Installation G. Inspection Tee Installation H. Removal
Schlüter -KERDI-BOARD Substrate, structural panel, bonded waterproofing
Substrate, structural panel, bonded waterproofing The universal substrate for tiles Perfect covering No matter whether you work with mosaics or large format tiles, an absolutely level substrate with straight
Plumbing Installations A homeowner guide to the City of Winnipeg plumbing requirements for a single-family dwelling
PLANNING, PROPERTY AND DEVELOPMENT DEPARTMENT Plumbing Installations A homeowner guide to the City of Winnipeg plumbing requirements for a single-family dwelling October 2014 contents General Information
Qualification Guide. BPEC 601/2514/7 - Level 1 Diploma in Plumbing Foundation. BPEC 600/9432/1 - Level 2 Diploma in Plumbing Foundation
Qualification Guide BPEC 601/2514/7 - Level 1 Diploma in Plumbing Foundation BPEC 600/9432/1 - Level 2 Diploma in Plumbing Foundation BPEC 600/5270/3 - Level 2 NVQ Diploma in Plumbing and Heating BPEC
WARDEN 4 ELECTRONIC WATER MANAGEMENT SYSTEM FEATURING:
WARDEN 4 ELECTRONIC WATER MANAGEMENT SYSTEM FEATURING: New Zealand made multi purpose plumbing control for Prison cells Vandal resistant controls Water saving fittings DESCRIPTION Warden 4 is a multi purpose
NATIONAL INSTITUTE OF BIOLOGICALS
Short Term Notice Inviting Quotations Quotations No. S.1-36/07/NIB/Engg. (Civil) Invitation to short term quotations for Repairing of damaged gypsum board false ceiling and painting with epoxy paint in
BIS WC Element / Lyft Alpro
W BIS WC Element / Lyft Alpro BIS WC Frames BIS Walkon BIS Walkon Quattro BIS Walkon Top BIS Walkon Comfort BISMAT VN (Quattro) BIS Control Panel Ellipse / Cube BIS Control Panel Space (BISMAT Top) BIS
Chapter 7 Plumbing Connections
Chapter 7 Plumbing Connections 7-1 General All plumbing equipment and installations must be designed, constructed, and installed in accordance with this code and where not specific, to the applicable provisions
GENERAL SPECIFICATION FOR CIVIL ENGINEERING WORKS SECTION 13 WORK FOR ELECTRICAL AND MECHANICAL INSTALLATIONS
GENERAL SPECIFICATION FOR CIVIL ENGINEERING WORKS SECTION 13 WORK FOR ELECTRICAL AND MECHANICAL INSTALLATIONS 13.1 13.2 2006 Edition SECTION 13 WORK FOR ELECTRICAL AND MECHANICAL INSTALLATIONS GENERAL
EXHIBIT "A. Technical Specifications for Water and Sewer Service Lines
EXHIBIT "A Technical Specifications for Water and Sewer Service Lines Water and Sewer Line Bedding and Backfill: Drawings show cross-section of trench, pipe laid on top of 6" min. bedding material, bedding
G. M. ENCLAVE PVT. LTD. Corporate office: AB-9, Salt Lake, Sec-I, Kolkata-700 064 Phone: 2334 8782, 2358 6037 Fax: 2337 6037 E-mail: [email protected].
G. M. ENCLAVE PVT. LTD. Phone: 2334 8782, 2358 6037 Fax: 2337 6037 E-mail: [email protected] BOOKING FORM MEENA RESIDENCY Teghoria Name Flat No Floor Area G. M. ENCLAVE PVT. LTD. Phone: 2334 8782, 2358
L_All_Vocatinal_Ed_Construction. Sector: Construction. Sr. No Specialisation Page No 1 Construction and Building Technology 02.
L_All_Vocatinal_Ed_Construction Sector: Construction Sr. No Specialisation Page No 1 Construction and Building Technology 02 1 P a g e 2 P a g e VOCATIONAL EDUCATIONAL QUALIFICATION FRAMEWORK (Sector -
When Should Examination Preparation Begin?
Texas State Board of Plumbing Examiners Tradesman Plumber-Limited Licensee Examination Review Course The following Examination Review Course is designed to assist a registered Plumber s Apprentice in preparing
Introduction. Contents. General. Materials and workmanship. Diagrams. Other regulations. References
Introduction General This Technical Booklet has been prepared by the Department of the Environment for Northern Ireland and provides for certain methods and standards of building which, if followed, will
SECTION 02630 STORM DRAINAGE SYSTEM
SECTION 02630 PART 1 - GENERAL 1.01 DESCRIPTION A. Section includes specifications for storm drainage systems including modifications and connections to existing storm drainage systems. 1.02 REFERENCE
ISSUE 08/08. KEEP INFORMED Look for other Good Idea Leaflets that could help you with your current project.
7648_GIL_074_07_08.qxd:GIL 074 01 06 27/8/08 16:47 Page 1 ISSUE 08/08 74 UNDERGROUND DRAINAGE Wickes stock a wide range of drainage products, whether it s to replace old drainage systems in the event of
plumbing products guide
plumbing products guide radiator pipe guide & seals A significant development in the drive to reduce air leakage and heat loss. Installations such as that shown are all too common. The detail is poorly
CAVITY DRAIN MEMBRANE SYSTEMS: SUMPS AND PUMPS GUIDANCE NOTES
CAVITY DRAIN MEMBRANE SYSTEMS: SUMPS AND PUMPS GUIDANCE NOTES Introduction: In most cases when installing the Isola Platon cavity drain system the actual level of water ingress or potential level of water
PART-II (COMMERCIAL / PRICE BID) DESIGN, SUPPLY AND INSTALLATION OF CUSTOMIZED STEEL LAB FURNITURE.AT N.C.C.S., PUNE
(An Autonomous Institution of the Department of Biotechnology, Govt. of India) N.C.C.S. Complex, Ganeshkhind, Pune University Campus, Pune 411007. PART-II (COMMERCIAL / PRICE BID) DESIGN, AND INSTALLATION
PUBLIC RESTROOMS, DESIGN INTENT
PUBLIC RESTROOMS, DESIGN INTENT 1.01 STRUCTURAL A. Where feasible, metal stud partitions will be constructed on a 6 high concrete curb. 1.02 MECHANICAL A. Restrooms will have a minimum of 15 air changes
1501-04-04-03-01:2009 HELLENIC CHNICAL SPECIFICATION. 32176 ежглеяис тгс йубеямгсеыс (теувос еутеяо) Sanitary ware, common 2009-12-23 ICS: 93.
32176 ежглеяис тгс йубеямгсеыс (теувос еутеяо) 2009-12-23 ICS 93160 1501-04-04-03-012009 H HELLENIC CHNICAL SPECIFICATION Sanitary ware common 10 313 111 45 ежглеяис тгс йубеямгсеыс (теувос еутеяо) 32177
GUIDELINES FOR OPERATORS OF MOBILE FOOD BUSINESSES: DESIGN, CONSTRUCTION
Southern Drive, Busselton WA 6280 All Correspondence to: The Chief Executive Officer, Locked Bag 1, Busselton WA 6280 Ph: (08) 9781 0444 Fax: (08) 9752 4958 Email: [email protected] Web: www.busselton.wa.gov.au
SECTION 33 41 13 PUBLIC STORM UTILITY DRAINAGE PIPING
SECTION 33 41 13 PUBLIC STORM PART 1 - GENERAL 1.01 SECTION INCLUDES A. Storm drainage piping, fittings, and accessories at proposed station areas and locations other than under and immediately adjacent
Borges Construction Company A limited liability Corporation Page1 of 1
Page1 of 1 The following is a quote to remodel the master bathroom at your home: Materials Labor Demolition 1 Dumpster $ 225.00 $ - 2 Remove existing carpet $ - $ 50.00 3 Remove existing tile $ - $ 80.00
2010 Residential Water Heater Replacement Check List
2010 Residential Water Heater Replacement Check List The intent of this check list is to provide installers a general reference for the enforcement of code requirements in the Greater San Diego Area. This
CONTRACT PRICE ADJUSTMENT PROVISIONS (CPAP)
CONTRACT PRICE ADJUSTMENT PROVISIONS (CPAP) Work Groups Composition and Weightings of Sub-indices CURRENT AS AT 1 JANUARY 2013 Issued by the CPAP Committee Distributed by the Association of South African
Most suitable piping material
Oct. 13 1st Edition NEW NEW Rigid PVC Pipe and Fittings with anti water condensation layer for air conditioning drainage ESON AC DRAIN PIPE ESON AC DRAIN Fittings ESON AC DRAIN Fittings ESON AC DRAIN Flexible
PLUMBING CARE AND REPAIR
PLUMBING CARE AND REPAIR No special skills are required for any of the repairs described in this section. Plumbing repairs are seldom dangerous unless leaking water is soaking areas where there are electrical
What to Expect From the Examination. How to Study the Plumbing Codes
Texas State Board of Plumbing Examiners Plumbing Inspector Examination Review Course The following Examination Review Course is designed to assist an applicant in preparing for the Plumbing Inspector examination.
WC flushing cistern single or dual flush 0.13 0.05 2 to fill in 2 minutes WC trough cistern 0.15 per WC 0.10 2 Wash basin tap size 1 2
HAC_C0.qxd 7/4/08 9: Page 74 Chapter Pipe sizing Pipes and fittings should be sized so that the flow rates for individual draw-offs are equal to the design flow rates shown in table.. During simultaneous
Brian Coppock, Regional Compliance Officer. Office of Statewide Health Planning and Development Facilities Development Division
Brian Coppock, Regional Compliance Officer Office of Statewide Health Planning and Development Facilities Development Division CHAPTER 6 WATER SUPPLY AND DISTRIBUTION 601.0 Hot and Cold Water Required.
How To Use An Akua Magnetic Lime Scale Preventing Device
AKUA MAGNETIC LIMESCALE PREVENTING DEVICES INTRODUCTION AND OPERATING MANUAL This manual contains information about Akua Magnetic Lime Scale Preventing devices, their assembly and usage rules. In order
31. ECO-INFO -- SEPTIC SAFE PROTECT YOUR HEALTH AND ENVIRONMENT YOUR SEPTIC PUMP-OUT SYSTEM with SELF ASSESSMENT TROUBLE SHOOTING GUIDE
31. ECO-INFO -- SEPTIC SAFE PROTECT YOUR HEALTH AND ENVIRONMENT YOUR SEPTIC PUMP-OUT SYSTEM with SELF ASSESSMENT TROUBLE SHOOTING GUIDE Edited 21/12/01 Wyong Shire Council has many non sewered areas that
SECTION 02400 - STORM DRAIN SYSTEM
SECTION 02400 - STORM DRAIN SYSTEM CONTENTS: Part 1 - General... 1 1.01 Work Included... 1 1.02 Related Requirements... 1 1.03 Reference Standards... 1 1.04 Quality Assurance... 1 1.05 Measurement And
B. Shop Drawings: Diagram power, signal, and control wiring.
SECTION 224500 - PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Emergency showers. 2. Eyewash equipment. 3. Eye/face wash equipment. 4. Combination units. 5. Water-tempering equipment. 1.2 SUBMITTALS
Planning Guide for Accessible Bathrooms AS1428.1-2009 including Amdt 1-2010, ambulant and complimentary items. Sydney Melbourne Brisbane Auckland
Sydney Melbourne Brisbane Auckland BACKRESTS RBA4150!SERIES BACKREST RBA4150!111 STAINLESS STEEL BACKREST RBA4150-101 Straight Arm Backrest RBA4150-201 Bent Arm Backrest Concealed mounting fl anges and
EFFECTIVE FEBRUARY 2014. note: drainage permit required to call for a dampproof inspection
EFFECTIVE FEBRUARY 2014 note: drainage permit required to call for a dampproof inspection 1. ROOF DRAINS/DECK DRAINS (INTERIOR ) All roof and deck drains within the perimeter of the building shall be APPROVED
How To Run A Test Lab In Rourkela
TESTING LABORATORY ROURKELA 1. Background: Keeping in view of the growing demand of quality of the products of the industries, Govt. has established Testing Laboratory, Rourkela, under the Directorate
Montgomery County Health Department Mobile Food Guidelines. Definitions
Montgomery County Health Department Mobile Food Guidelines Definitions Commissary A permitted food establishment to which a mobile unit returns on a daily basis for such tasks as discarding liquid and/or
TECHNICAL SPECIFICATIONS & TERMS AND CONDITIONS FOR SOLAR WATER HEATER (FPC/ETC)
TECHNICAL SPECIFICATIONS & TERMS AND CONDITIONS FOR SOLAR WATER HEATER (FPC/ETC) Prepared by Committee for Technology Assessment and Analyzing the installation of Solar Water Heater Systems in Government
INSTALLATION INSTRUCTIONS
INSTALLATION INSTRUCTIONS ODEON IN-WALL TANK K-6283K/ K-6284K/ K-6286K Read installation guide in illustration and word file carefully, and install the tank according to instructions in the guide to avoid
Sealant. 30" Model No. 35020. D: 17-7/8" TO 18-3/8" (454 to 466mm) W: 29-3/4" TO 30-1/4" (756 to 768mm) Under Countertop Installation
INSTALLATION INSTRUCTIONS CARE AND MAINTENANCE London Kitchen Sinks 24" Sink model number 35030 30" Sink model number 35020 36" Sink model number 35040 Thank you for selecting Porcher. To ensure this product
Issue of the Guidelines on Prevention of Water Seepage in New Buildings
graphic: Buildings Department Your REF 來 函 檔 號 :. OUR REF 本 處 檔 號 :.BD GR/1-55/173 FAX 圖 文 傳 真 :..28400451 TEL 電 話 :..2626 1717 www.info.gov.hk/bd To : All Authorized Persons 7 March 2005 Registered Structural
Installation Guide. Bath and Wall Surrounds SERIES 7104 1021861-2-B
Installation Guide and Wall Surrounds SERIES 7104 1021861-2-B Thank You For Choosing Sterling We appreciate your commitment to Sterling value. Please take a few minutes to review this manual before you
PRESENTATION ON REPAIR AND REHABILITATION OF BUILDINGS DAMAGED IN EARTHQUAKE. By H P Gupta & D K Gupta
PRESENTATION ON REPAIR AND REHABILITATION OF BUILDINGS DAMAGED IN EARTHQUAKE By H P Gupta & D K Gupta DIFFERENT TYPES OF DAMAGES 1.Minor cracks 0.5 to 5 mm wide in load or non-load bearing walls 2.Major
Turnkey Projects, Conversions, Restorations & Property Management. Marsalforn - Gozo APARTMENT FINISHING EXCLUSIVE PACKAGE
Turnkey Projects, Conversions, Restorations & Property Management Marsalforn - Gozo APARTMENT FINISHING EXCLUSIVE PACKAGE Reg. Office: Karlu Galea Street, Victoria, Gozo Malta. T. 2155 6600 M. 9943 4391
APPLICATION FOR FITOUT OR PLAN ASSESSMENT UNDER THE FOOD ACT 2001
Health Protection Service Howard Florey Centenary House, 25 Mulley Street, Holder ACT 2611 Locked Bag 5005, Weston Creek ACT 2611 Phone: (02) 6205 1700 Fax: (02) 6205 1705 Website: www.health.act.gov.au
Stainless Steel Single and Dual Circulation Kits
Instruction Sheet P/N 160780 01 Stainless Steel Single and Dual Circulation Kits Introduction The single and dual high-pressure circulation kits allow you to vary and control the circulation rate of coating
INTERCEPTORS TABLE OF CONTENTS S-WD-INTER-1 0812
TABLE OF CONTENTS Pictorial Index Product Recommendations Grease Interceptors Commonly Specified Options Typical Installations Oil Interceptors Commonly Specified Options Typical Installations Sediment
SECTION 33 11 00.11 POLYVINYL CHLORIDE (PVC) PIPE
SECTION 33 11 00.11 POLYVINYL CHLORIDE (PVC) PIPE PART 1: GENERAL 1.01 SECTION INCLUDES PVC pressure pipe and fabricated fittings in nominal sizes 4-inches through 12-inches with cast iron pipe equivalent
SPECIFICATION FOR PIPE SUBSOIL DRAIN CONSTRUCTION
SPECIFICATION FOR PIPE SUBSOIL DRAIN CONSTRUCTION 1. SCOPE Pipe subsoil drains shall be constructed in accordance with this specification and in conformity with the lines, grades and cross-sections shown
FLUSHING CISTERNS. product catalogue
FLUSHING CISTERNS product catalogue 2 Beautiful power of water 5 CONCEALED SYSTEMS 23 FLUSHING PLATES 29 NO-CONTACT FLUSHING 35 EXPOSED FLUSHING CISTERNS 41 SPARE PARTS The line of concealed systems is
STANDARD SPECIFICATION. for. Plumbing, Heating, Hot Water, Cold Water & Electrical work. Sussex Lodge London W2 & 16 Stanhope Terrace London W2
STANDARD for Plumbing, Heating, Hot Water, Cold Water & Electrical work undertaken by owners within the building known as Sussex Lodge London W2 & 16 Stanhope Terrace London W2 BPME Consulting Engineers
Carriers, Fixtures & Piping
Regardless of application and/or installation needs, there are fixture supports available to meet even the harshest design requirements. by William M. Smith Over the years, I m sure that each of you in
Syphonic Roof Drainage
Page 1 T E C H N O L O G Y 2:39 pm Syphonic Roof Drainage P L U M B I N G 23/5/03 A D V A N C E D Prod & Price Gd.for PDF Product Guide SYPHONICS Advanced Roof Drainage Technology Geberit Syphonics Geberit
THE VOID LETTABLE STANDARD
THE VOID LETTABLE STANDARD North West Leicestershire District Council is responsible for allocating empty Council owned homes. The Lettable standard has been agreed in consultation with the tenants of
Mechanical Services Standard Specification 9.0 - Above Ground Soil, Waste and Ventilation Pipes
Mechanical Services Standard Specification 9.0 - Above Ground Soil, Waste and Ventilation Pipes May 2010 For ROYAL HOLLOWAY UNIVERSITY OF LONDON Prepared For The Estates Division By: Hulley & Kirkwood
A SMALL-SCALE ARSENIC AND IRON REMOVAL PLANT
A SMALL-SCALE ARSENIC AND IRON REMOVAL PLANT Introduction Groundwater is the main source of water supply in Bangladesh. Groundwater abstracted from tubewells was considered to be the best option for water
CHAPTER 11 STORM DRAINAGE
CHAPTER STORM DRAINAGE SECTION PC 0 GENERAL 0. Scope. The provisions of this chapter shall govern the materials, design, construction and installation of storm drainage. Storm water discharge shall be
Prepare a drainage system layout and specification notes for a low- rise building.
STUDENT MATERIALS Prepare a drainage system layout and specification notes for a low- Outcome 1 - rise building. In this outcome you will study the technology of below and above ground drainage systems.
Plumbing Code in Commercial Kitchens. NH BOA May 9, 2012
Plumbing Code in Commercial Kitchens NH BOA May 9, 2012 Main Topics Grease Interceptors Indirect Waste Receptors Cleaning Chemical Dispensers Thermal Expansion IPC - Chapter 10 Traps Interceptors Separators
A. Accessible Fixture: Emergency plumbing fixture that can be approached, entered, and used by people with disabilities.
SECTION 224500 - EMERGENCY PLUMBING FIXTURES PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification
SECTION 02530 STORM DRAINAGE STRUCTURES. 1. Trench excavation, backfill, and compaction; Section 02250.
02530-1 of 5 SECTION 02530 STORM DRAINAGE STRUCTURES 02530.01 GENERAL A. Description Storm drainage structure construction shall include, but not necessarily be limited to, furnishing and installing or
BUILDING TRADES II PLUMBING: ROUGH-IN AND FINAL TEACHER S GUIDE
BUILDING TRADES II PLUMBING: ROUGH-IN AND FINAL TEACHER S GUIDE INTRODUCTION This Teacher s Guide provides information to help you get the most out of Plumbing: Rough-In and Final. The contents in this
BOQ SPECIFICATIONS. The Blind system consist of a coated aluminium tube of 38 mm diameter with provision of fabric clamping.
BOQ SPECIFICATIONS VERTICAL BLINDS Vertical Blinds made of glass fibre fabrics in width 5 (or 4 ). Minimum overlapping of ¾ in fabric. Top aluminium anodized rail of 1.4 mm thickness. 2 inch wide channel
AT FIRST SIGHT Important informations
Technical catalogue AT FIRST SIGHT Important informations TIPS FOR USING THIS GUIDE Our new technical catalogue includes now all important information you will need for planing or call for tenders. Every
PLUMBING PERMIT APPLICATION (PLUMBING PERMIT TO BE SECURED 24 HOURS BEFORE WORK STARTS)
RESIDENTIAL ONLY Edgehill Shopping Center 43 S. DuPont Hwy. Dover, DE. 19901 Phone: 302-741-8600 Fax: 302-741-8631 Thurman Adams State Service Center 544 South Bedford Street Georgetown, DE 19947 Phone:
After reading this lesson you will be able to: 12.3 IMPORTANCE OF ROOF 12.4 TYPES OF ROOF IN A HOUSE
86 :: Certificate in Construction Supervision (CIVIL) 12 ROOF 12.1 INTRODUCTION The structure provided to cover the house surface (floor) is known as roof. For different situation and requirement, it is
Welcome: What is U Drain? Drain Materials. Flow
Welcome: Thank you for looking into the U Drain floor drain system. This paper will explore the functional features of the U Drain and why it is superior to other grated systems in the marketplace. We
