UH8-RF - Installation Manual

Similar documents
HERZ-Thermal Actuators

Installation Guide for Hive Active Heating

Wireless Thermostats 230v and Battery Operated Instruction Manual

Programmable Room Thermostat 7 Day (5-2 Day) Models: / Power Supply: Battery / Mains

Drayton Digistat +2RF/+3RF

HCE80/HCC80/HCE80R/HCC80R

Sensi TM. Wi-Fi Programmable Thermostat MANUAL OPERATION. Version: March Emerson Electric Co. All rights reserved.

RVL470. Heating Controller. Building Technologies HVAC Products. Series B

Operating Instructions DT, PRT, PRT/HW PRT-R, PRT-R2

Heating Controller. Building Technologies HVAC Products

TICS - Integrated Control Strategy TICS - Total Integrated Control Strategy Mid Range System

it500 Internet Thermostat INSTALLER MANUAL

RVR Hybrid System Installer Instructions RVR Hybrid System Controller Installation Instructions

Floor Heating Warehouse.co.uk

PART 8: FIELD WIRING. n WARNING NOTICE. Boiler Manual

RF 1. Contents: Connecting diagram. Detailed information:

Radio Thermostat Clock Part Number: Installation & User Instructions. Suitable for all Ferroli Combination Boilers

contents Leading the way in intelligent automation INELS Wireless? Why Click Accessories Complete control

TYXIA. * _Rev.1* Installation and User Guide. Wireless receiver. TYXIA RF channel

Install Guide CT101. Caution. Caution

Wireless 7 Day Programmable Room Thermostat

Alpha Climatic Programmable Modulating Boiler Energy Manager. Installation and User Instructions

Install Guide 3M-50. Caution. Caution

SET1E. Installation & User Instructions. Electronic timeswitch for heating & hot water. Certification Mark

Installation Guide. VisionPRO. TH8000 Series. Need Help? This manual covers the following models. System Types

RDJ10RF/SET. Wireless room temperature controller with 24-hour time switch and LCD. Programmable, for heating systems

Universal control module for motorized devices

Installation Guide. LR-HWLV-HVAC TouchPRO Wireless. System Types

Smile. The All-In-One Heating Controller

ABB i-bus KNX Fan Coil Controller FC/S 1.1

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

ecomax Instructions for use Wall hung room sealed fan assisted condensing boilers For the user

DUAL SENSING DIGITAL THERMOSTAT PRODUCT INSTRUCTIONS. Construction Automotive Industry

TRANSMITTER RECEIVER THESE INSTRUCTIONS APPLY IN THE UK ONLY THESE INSTRUCTIONS ARE TO BE LEFT WITH THE USER OR AT THE APPLIANCE. Digistat Optimiser

Nest Learning Thermostat Installation Guide. Installation step-by-step

Install Guide CT100. Caution. Caution ENGLISH. disconnect the power supply before beginning work.

CM705B - Universal Expander Module CM707B - Plug On Zone Expander Security Systems

MAKING MODERN LIVING POSSIBLE. living connect. Installation and User Guide. Danfoss heating

Disabled Toilet Alarm. Contractor Pack. Installation & Operating Instructions

DC1100 & 1400 Energy Controllers. Satchwell DC1100 & DC1400 for energy-efficient temperature control in smaller buildings.

HVAC-32A. Operation Manual. Specifications. Digital Multistage Air Conditioning Controller with inbuilt Outside Air Economy function

Electric Rotary Actuator - On/Off or programmable control actuator

User Manual THR840DUK Digital Thermostat

15 Series - Electronic step relay and dimmer. Features SERIE

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q R0001

2.0 Installation 1. Remove the cover using a small flat blade screwdriver. Figure 2: Cover Removal

Table of Contents. Introduction. Radio Frequency Control. Initial setup Setting the time. Setting the temperature

Installer Guide smart connect

RY2 miniature industrial relays

HP 5 Microprocessor Control for Mammoth Water Source Heat Pumps

OZW30. Central Unit SYNERGYR

Variety of Control Options Control is possible via wall switches, remote control systems or integration into building management systems.

Table of Contents. 1 - Specifications Installation Wiring User controls...7

Manual & Technical Documentation V1.1

Short Range Wireless Switch System Handheld 8 Installation and Operations Guide

RRV934. Multi-controller. Synco living

3PH2 or 3PHE 3 Phase Control Board

Heating and Hot Water Services Controls General Technical Specification

Square D Clipsal DIN-Rail Four-Channel Auxiliary Input Unit

Fully Pumped Systems

Power Socket (2 Gang)

USER MANUAL WARNING! CONTENTS MODEL 1 SPECIFICATIONS READ ALL INSTRUCTIONS BEFORE PROCEEDING. Non-Programmable Single Stage Heat/Cool Thermostat

Product and functional description

Modular I/O System Analog and Digital Interface Modules

MAKING MODERN LIVING POSSIBLE. living connect. Installation and User Guide. Danfoss Heating Solutions

Aerona Air Source Heat Pumps

SEZ220. Signal Converter. Synco 200. With preprogrammed standard applications Freely programmable Menu-driven operation. Use

Installing the Tracer ZN517 Unitary Controller Ordering number: ,

Adjustable room thermostat for heating only or cooling only systems

ETHERNET IRRIGATION CONTROLLER. Irrigation Caddy Model: ICEthS1. User Manual and Installation Instructions

INSTALLATION GUIDE. Card Reader & Controller with KIM Swipe Reader for Solitaire 850 / 950 / 850L Learnlok PK2930

SWITCH! DESCRIPTION. ENVIRONMENTAL SPECIFICATIONS Operating Temperature: 0 C to +40 C SPECIFICATION SHEET:

ELITE-L Series. ELITE - Low Voltage / Dry contact Remote Control System

RUST ELECTRONICS LTD. Remote Switching Unit RCU-O4

TOA 900 SERIES II MIXER POWER AMPLIFIER

its ELECTRIC POSITION for electric heat, or set the units fan control appropriately to ELECTRIC or another appropriate setting.

Shutter Actuator Standard, 4-fold, 230 VAC, MDRC RA/S , GH Q R0111. ABB i-bus EIB

EK908FHL - Thermostat for floor heating

Single Channel Loop Detector

REB 1 REB 3 REB 5 REB 6 REB 8 REB 10 REB 12 REB 16

ZMR 80 STEREO MODULAR ZONER USERS MANUAL

FIREDEX Conventional Fire Panels

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

TAC I/NETTM MR-AHU-HP. Application Specific Controller

Electric Flow Boiler

FAQs. Conserve package. Gateway... 2 Range Extender... 3 Smart Plug... 3 Thermostat... 4 Website... 7 App and Mobile Devices... 7

your comfort. our world. User Guide Altherma HT For your new Daikin Altherma high temperature heat pump

RI-215A Operator s Manual. Part Number: RK Revision 0 Released: 10/3/05

SET3M. electro-mechanical 24 programmer for heating & hot water. Installation & User Instructions

Safety Warnings and Guidelines

HSP GmbH Zum Handwerkerhof Wendelstein Tel / Fax: / Web: HSP@hsshsp.de NTG-3000.

TS93 EMR T/PT/TDE. Surface applied door closer

Applied Electronics. Commercial Dimming System UPDATE NOTICE

CO2 Alarm. Operation. Application

Installation instructions. For the competent person. Installation instructions. VRT 350f. VRT 350f GB, IE

R.C.C.B. s two-pole LEXIC

UNDERFLOOR HEATING SYSTEMS DETAILS AND NOTES

CX Zoner Installation & User Guide

mecotron Safety relay ESTOP-2 For emergency stop monitoring

PAC1 Door Access Controller

Transcription:

MODEL: UH8-RF

UH8-RF - Installation Manual Installation Description The UH8-RF is an 8 Zone central wiring centre for use with SOLFEX RF thermostats. The UH8-RF can be used to control any actuator or valve which requires a 230v AC signal. At the same time the UH8-RF offers the ability to operate a boiler or other heat source through a volt free output with changeover contacts, which gives you both a heat on signal and a heat off signal. Additional outputs designed for use with hot water or underfloor heating systems, are also included as standard. These are the pump and valve outputs which would normally operate a manifold pump or a manifold valve, and the H/W output which is used to send a hot water on and hot water off signal. Any output which is not needed can be ignored. 99 channel numbers are available allowing up to 99 different UH8-RF wiring centres to be operated in close proximity. With 8 thermostats per wiring centre this gives you up to 792 distinct heating zones. When wiring directly to the heat source is not possible, a radio link is provided to remotely enable a separate receiver, the RF-Switch. Test switches are included for the installation engineer and further options include creepage protection and pump delay. Operation Each RF thermostat used on this system can be configured as a thermostat for either a radiator zone, underfloor heating zone or in combination mode, hot water and heating zone. When the thermostat sends a signal for heating, the UH8-RF will provide a 230v AC output on the paired zone and also bring on the boiler/other heat source output. At the same time the UH8-RF can send a radio signal to the RF-Switch. If the thermostat is configured as an underfloor heating zone, the UH8-RF will also start the pump and valve outputs. If an enable signal is received from a hot water time clock on the system, only the H/W output will become active. This is a timed output, which is normally fed to a cylinder thermostat, then to a valve, but could also be used for towel rails. In either case the valve auxiliary switch would operate the boiler/other heat source. Other functions Creepage During hot weather the heating is not normally needed as often, this means that valves and pumps that are not being used can seize and refuse to operate. To prevent this, it is good practice to operate the valve or pump once a day, the creepage function does this for you. Once enabled the UH8-RF will operate each valve or pump for 1 minute, only if the outputs have not been operated by a thermostat, within the preceding 24 hours. This function does not operate the boiler output. Pump Delay Some valves or actuators can take more than a minute to open, if the boiler and pump operate before the valve is open it can force a boiler to go to lockout and stop operating. This function delays the operation of the pump and boiler for 2 minutes to give the actuators and valves time to open. Engineers Test Switches These switches allow the installation engineer to test the operation of the valves, actuators, pumps hot water or boiler, without having to install the thermostats. The UH8-RF can be mounted directly to a wall using four screws or alternatively, the unit can be DIN rail mounted. When DIN Rail mounting, you first need to insert the two clips provided on the back of the UH8-RF, as shown in the image; On the back of the UH8-RF, position the clip in the middle and slide down. Points A and B locate in the corresponding holes and lock into place. Locate the UH8-RF onto the DIN rail from the top. Pull the clip down and push the bottom of the UH8-RF onto the DIN rail. Releasing the clip will lock the UH8-RF in place on the DIN rail. To remove the UH8-RF, pull both clips down and remove from the DIN rail. Insert clip here. Then Slide down to lock in place. A B 2 Wiring Centre 3

UH8-RF Wiring The UH8-RF should be fitted as close as possible to the equipment it is controlling, but never within a metal enclosure, if this cannot be avoided an extension antenna (EA1) must be fitted and placed outside the metal enclosure. Connections Mains Supply Power supply into the UH8-RF which should be fused at 5 amps these connections are marked L = live or phase 230v AC 50/60Hz N = Neutral E = Earth Boiler This is the main call for heat for the system, there are 3 connections; C = common NO = normally open NC = normally closed Electrically this is a two-way switch, whatever supply is placed on the C connection, is fed to the NC connection when there is no call for heat. This is then switched to the NO connection when there is a call for heat. Most systems will use the common (C ) and normally open (NO) connections. H/W This output is used to control a hot water cylinder thermostat C = common NO = normally open NC = normally closed Electrically this is a two-way switch, whatever supply is placed on the common connection, is fed to the NC connection when there is no call for hot water. This is then switched to the NO connection when there is a call for hot water. Normally the NO connection would be wired to the hot water cylinder thermostat, then from there to the hot water valve, the valve auxiliary switch will then start the boiler/other heat source. Most systems will use the common and normally open connections. Zones 1 8 Zones outputs are clearly marked L = live out to actuator or valve N = neutral to actuator or valve There are two connections live (L) and neutral (N), both terminals marked L are the same and both terminals marked N are the same. Each zone output is numbered, Zone 1 will respond to radio signals from the thermostat paired to zone 1, Zone 2 output will respond to thermostat numbered 2 etc. Pump Used for an underfloor heating manifold pump. Connections are clearly marked L = live or phase 230v ac 50/60Hz N = Neutral E = Earth When a thermostat configured as an under-floor heating zone sends a call for heat to the UH8-RF, the live output will supply 230v to the manifold pump. It is recommended that this is fed through a high limit switch placed on the heating manifold, to protect against mechanical failure of the manifolds temperature control. Valve Used for an underfloor heating manifold valve. Connections are clearly marked L = live or phase 230v ac 50/60Hz N = Neutral E = Earth When a thermostat configured as an under-floor heating zone sends a call for heat to the UH8-RF, the live output will supply 230v to the manifold valve. Fuses Each UH8-RF is protected by 3 fuses Fuse 1. 800mA, 20mm anti-surge fuse, this fuse supplies and protects the internal electronics. Fuse 2. 5amp, 20mm anti-surge fuse, this fuse supplies power to all 230v outputs from the board it protects the zone, pump and valve outputs. Fuse 3. 2amp, 20mm anti-surge fuse, this fuse supplies power to the pump and valve outputs, it protects the board from overloads caused by jammed valves or seized pumps. 4 Wiring Centre 5

Wiring Diagram UH8-RF 6 Wiring Centre 7

System Setup Step 1 Each UH8-RF board has 2 rotary switches labeled CHANNEL NUMBER, this number is used to identify the board and must be set to a unique number. If you are only installing one UH8-RF, you would normally set the channel number to 01. On the rotary switches this would be 0 tens and 1 unit. If you were installing 15 UH8-RF units, you would number them 01 to 15, fifteen would be 1 tens and 5 Units. You can choose any numbers you wish up to 99 but no 2 units within radio range can have the same number DIP Switches There is a 4 way dip switch responsible for 3 functions; 1. Pump Delay 2. Creepage Enable 3. Boiler RF test Engineers test switches These are a block of 12 dip switches, used to test each zone, boiler, pump and HW outputs. To enable any output, put the switch in the ON position. When installation is complete all switches MUST be in the OFF position. Record the rooms names connected to each zone with the zone number and record the channel number you have selected, you will need this information when installing the thermostats. That completes the setup process. Step 2 is to configure the thermostats and will depend on which model you have, please refer to the thermostat instruction manual. Rating Supply Power Consumption Max load on boiler output Max load on H/W output Max load for zone outputs Max Total Load Optional Accessories RF-Switch Boost Extension Antenna 230v AC 50HC 7W 3A 230v AC restive 3A 230v AC restive 3A 230v AC restive 5 Amps (Remote Boiler Enable) (Repeater) (EA1) 4. Not used In normal use these DIP switches can be ignored and should be left in the off position. DIP Switch 1 To enable the pump delay, put switch 1 to the ON position. DIP Switch 2 DIP Switch 3 To enable creepage protection, put switch 2 to the ON position. Pairing to the RF-Switch On the RF-Switch, press and hold the Boiler pairing button for 5 seconds. The Boiler status LED will switch on. Press and release the pairing button on the UH8-RF. When the RF-Switch detects the pairing signal from the UH8-RF, the Boiler LED will switch off, pairing complete. The Boiler RF test switch is used to test communications with the RF- Switch receiver, used for remotely enabling the boiler. The UH8-RF sends a repeating on/off signal to the RF-Switch receiver, when installation is complete, switch number 3 MUST be in the OFF position. Put switch 3 to the ON position, the UH8-RF will send a repeating on/ off signal to the RF-Switch. The Boiler LED on the RF-Switch will flash to indicate successful communication. 8 Wiring Centre 9

System Configuration Notes 10 Wiring Centre 11

Want More Information? Call our support team on: +44 (0) 1772 312847 Or view technical specifications directly on our website: www.solfex.co.uk PDF FAQ Twitter: SOLFEXLTD Facebook: /solfexenergysystems