Low-Voltage Controls and Distribution

Similar documents
3K Load-Break Switches The Program for Safety and Performance. sentric

SIRCOVER. Manual changeover switches from 125 to 3200 A. Changeover switches. Function. Advantages. The solution for.

Type: DILM115(RAC240) Article No.: Sales text Contactor,55kW/400V,AC operated. Ordering information

Emergency stop As an emergency switching off/emergency stop device. Standards According to IEC/EN , VDE 0113 Part 1

BETA Protecting SITOR Semiconductor Fuses

Series 8146/5-V37 and Series 8150/5-V37

Manual Motor Starter MS 116 up to 16 A Technical Data

Manual motor starter MS116

Type: DILM50(230V50HZ,240V60HZ) Article No.:

Electronic overload relay EF19 and EF45

MEDIUM VOLTAGE CE-BF SWITCHBOARDS. UP TO 40.5 kv. CE - BF - C - en - REV

UniGear ZS1. Medium voltage, arc proof, air insulated switchgear for primary distribution

3.1.1 Full Type Tests & Routine Tests according to Clause 8 2 & Instructions For Installation, Operation & Maintenance

Switching Devices Contactors and Contactor Assemblies Special Applications

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2...

3RT1015-1BB41 CONTACTOR, AC-3 3 KW/400 V,

Low voltage Direct Current Network. Compact NSX DC PV. Circuit breakers and switch disconnectors for solar application.

Low Voltage Products. Switches Automatic Transfer Switches

BETA Switching. Switching Devices. 5TT5 8 Insta contactors, AC technology. Overview

SENTRON Switching and Protection Devices Air Circuit Breakers

Type-Tested Power Distribution Board 8PT with Rear Busbars. sivacon

R.C.C.B. s two-pole LEXIC

The power distribution board that sets new standards

Type: DILM32 10(24V50HZ) Article No.:

Type: DILM9 10(24VDC) Article No.:

Catalogue May EasyLine XLP Fuse Switch Disconnector pole

Technicaldata General

AF / AF09Z stack 3-pole Contactors AC / DC Operated - with Screw Terminals

Electronic overload relay EF65, EF96 and EF146

Relés e Contatores de Estado Sólido SIRIUS

Breakers and Switches. Switches Switch-disconnectors OT, OETL, OTDC and OTM

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

SIVACON The Versatile Low-Voltage Switchboard

PRODUCT GUIDE. SL Medium Voltage IEC Vacuum Contactors

Micro Contactors. Micro Contactor Relays. Micro Contactors With Solder Pins. Coil voltages. Micro Reversing Contactor. Technical Data.

Technical data UNIBLOCK UBSF

Low Voltage Switchboards The Best Technical Solution for Your Ship

Circuit Breakers. Next Generation of Protection Capabilities

Molded Case Circuit Breaker Specifications Bulletin Number 140U-D

P System Cubicles. Certified for more safety

HERZ-Thermal Actuators

Mini Motor Contactor J7KNA Main contactor Accessories Approved Standards Standard Guide No (US,C) Ordering Information tage Model Number Legend gear

Plug and Socket Devices CES 63 A Series 8579

Type: EASY719 DC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

Single-phase ( V) voltage monitoring: Undervoltage Overvoltage Window mode (overvoltage + undervoltage) Voltage fault memory selectable

ELEKTROTECHNISCHE WERKE FRITZ DRIESCHER & SÖHNE GMBH D MOOSBURG TEL FAX

SICONT Limit Switches Type 3SE3 upto 500 VAC, 600 VDC, 10A

NF71E-.. / NFZ71E-.. Contactor Relays AC / DC Operated - with Screw Terminals

Redundancy Module QUINT-DIODE/40

ELEKTROTEHNI KO PODJETJE Leskoπkova cesta 12, 1000 Ljubljana, SLOVENIA

Catalog. Modular DIN rail components Installation contactors

PPS-PPQ-BT-PIAS RESIN INSULATORS FOR OIL INSULATED ELECTRICAL MACHINES

5SV Residual Current Protective Devices

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

Components for System Solutions E9/5. Ex d Enclosure System Made of Light Metal or Stainless Steel, "Flameproof Enclosure" Series

Product and functional description

Switching Devices. 8/2 Introduction. 8/5 5TE8 control switches. 8/8 5TE4 pushbuttons. 8/11 5TE5 light indicators. 8/13 5TE On/Off switches

Givare NC-SRS 280 och 880

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N

The complete range of consumer switchboards and switchgear

Protection Equipment

LV MCC LOW VOLTAGE SWITCHGEAR MOTOR CONTROL CENTRE PRODUCT GUIDE

Residual Current Protective Devices

Vario-Series Accessories

49 Series - Relay interface modules A. Features

D-Line Contactors, Overload Relays and Accessories

E-STOP relays, safety gate monitors

Plug and Socket Devices SolConeX 16 A Series 8570

pole, 8 A Safety relay. Screw terminal. 35 mm rail (EN 60715) mounting. 2 CO (DPDT) 8/15 250/400 2, /0.65/0.

FUSERBLOC. 20 to 1250 A Manual operation. 142 General Catalogue SOCOMEC. Fuse combination switches

LC1D65AM7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 65 A V AC coil

STEP-PS/1AC/12DC/1.5. Extract from the online catalog. Order No.: DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase

Uncompromising safety and comfort The next generation of miniature circuit breakers MCB S 200/S 200 M

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

SURGE PROTECTIVE DEVICES

Contact expansion modules

48 SERIES Relay interface modules 10 A

Technical catalogue. Modular DIN rail components Installation contactors

Electronic timer CT-VBS OFF-delayed without auxiliary voltage, for DC contactors Data sheet

Thermal-Magnetic Circuit Breaker M1-..

DEK-REL- 24/1/SEN. Extract from the online catalog. Order No.:

MNS is Switchgear System Technical Overview

PSR The compact range Description

3RV Motor Starter Protectors up to 100 A

SUBJECT: How to wire a motor starter Number: AN-MC-004 Date Issued: 2/08/2005 Revision: Original

Digital input modules

ABB i-bus KNX Fan Coil Actuator, MDRC FCA/S 1.1M, 2CDG R0011

ABB i-bus KNX Switch Actuator, x-fold, 16 A, MDRC SA/S x , 2CDG1101xxR0011

REVIEWED BY CAPITAL PROJECTS MANAGER (DAN REDDY) GENERAL MANAGER EQUIPMENT ENGINEERING & ASSET MANAGEMENT (HAMILTON NXUMALO)

know-how Giant in distributing electricity for industry Prisma GK

Product and Applications Description. Application Programs. Example of Operation. GAMMA instabus Technical Product-Information.

GE Power Controls. MiniFORM Switchboards

Application Switchgear for industrial and commercial applications. U e V AC 230/ (per pole)

Mini Circuit Breakers, Fuse Blocks, and Electronic Circuit Protection

ESP 120 M1, ESP 208 M1, ESP 240 M1, ESP 415 M1, ESP 277 M1, ESP 480 M1 and M1R variants. Installation instructions ESP M1/M1R mains protectors

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start * see variants. Applications.

34 Series - Slim electromechanical PCB relays 6 A. Features SERIES 34.51

Our brand POWER DYNAMIC PASSION COMMITMENT CREATIVITY. A strong brand for strong products: 8PU Premium. MV Energy

Instruction Bulletin. MCS025 Sync-Check Module Installation Sheet

Pluggable interface relays CR-P Pcb relays

Transcription:

SENTRON Switching and Protection Devices Switch Disconnectors 8US Busbar Systems Reference Manual pril 2009 Low-Voltage Controls and Distribution

SENTRON Switching and Protection Devices Switch Disconnectors, 8US Busbar Systems 4 Introduction 3K, 3KE, 3LD Switch Disconnectors 3K, 3KE Switch Disconnectors up to 1000 7 General data 12 Floor mounting 3LD Main and EMERGENCY-STOP Switches up to 125 14 General data 17 Front mounting 20 Floor mounting 21 Distribution board mounting 22 Molded-plastic enclosures 23 ccessories 3KL, 3KM Switch Disconnectors with Fuses 3KL Switch Disconnectors with Fuses up to 800 25 General data 28 Surface mounting and installation 3KM Switch Disconnectors with Fuses and Isolating Plug Connector up to 400 30 General data 33 For snapping onto busbars 8UC Door-Coupling Rotary Operating Mechanisms 36 For 3K switch disconnectors 39 Individual parts 40 Operating mechanisms for fixed mounting 3NP, 3NJ4, 3NJ5 Fuse Switch Disconnectors 3NP Fuse Switch Disconnectors up to 630 41 General data 47 3NP4 for power distribution 51 3NP5 for extended technical requirements 3NJ4, 3NJ5 In-Line Fuse Switch Disconnectors up to 1250 54 General data 58 1-pole switchable 59 3-pole switchable 60 ccessories 8US Busbar Systems 61 General data 40 mm busbar systems 62 General data 63 Base assemblies 64 Infeed and connection components 65 Busbar adapters and device holders 68 ccessories 60 mm busbar systems 69 General data 70 Base assemblies up to 630 73 Base assemblies up to 1600 74 Infeed and connection components 76 Busbar adapters and device holders 79 Bus-mounting fuse bases 80 ccessories Siemens 2009

Switch Disconnectors, 8US Busbar Systems Introduction Overview Type 3LD20 3LD21 3LD22 3LD25 3LD27 3LD28 3LD main and EMERGENCY-STOP switches from 16 to 125 Rated uninterrupted current I u t 35 C ambient temperature 16 25 32 63 100 125 Rated operational voltage U e V 690 690 690 690 690 690 C-3 motor load switches Operational switching of individual motors t 220... 240 V kw 3.0 4.0 5.5 11.0 18.5 22.0 t 380... 440 V kw 5.5 7.5 9.5 18.5 30.0 37.0 t 660/690 V kw 5.5 7.5 9.5 15.0 22.0 30.0 C-23 main control switches, repair switches Frequent, but not operational switching of single motors t 220... 240 V kw 4.0 5.0 6.0 11.0 18.5 22.0 t 380... 440 V kw 7.5 9.5 11.5 22.0 37.0 45.0 t 660/690 V kw 7.5 9.5 11.5 18.5 30.0 37.0 Switch versions Front mounting Central -- -- Four-hole Floor mounting Central -- -- Four-hole Distribution board mounting Molded-plastic enclosures Metric screwed glands Switch accessories 4th pole (N conductor) (leading switch-on, delayed switch-off) N terminals PE/ground terminals uxiliary contacts 1 NO + 1 NC vailable -- Not available 4 Siemens 2009

Switch Disconnectors, 8US Busbar Systems Introduction Type 3NP 3K 3NJ4 SENTRON Rated uninterrupted current I u t 35 C ambient temperature 160 to 630 63 to 1000 160 to 1250 Rated operational voltage U e V 690 690 690 C-21 t 400 V t 500 V t 690 V C-22 t 400 V t 500 V t 690 V C-23 t 400 V -- t 500 V -- -- t 690 V -- -- Switch versions Front mounting -- -- Floor mounting -- Busbars 40 mm -- -- 60 mm -- 185 mm -- -- Molded-plastic enclosures -- Switch accessories uxiliary contacts 1 NO + 1 NC -- -- 1 CO Fuse monitoring With circuit breakers With electronics Current transformers -- -- vailable -- Not available Siemens 2009 5

Switch Disconnectors, 8US Busbar Systems Introduction Type 40 mm busbar systems 60 mm busbar systems 8US busbar systems dapters for SIRIUS size S00/S0 Motor starter protectors/circuit breakers Motor starter protectors/circuit breakers + lateral auxiliary switch Contactors + overload relay Direct-on-line start load feeders Reversing feeders dapters for SIRIUS size S2 Motor starter protectors/circuit breakers Motor starter protectors/circuit breakers + lateral auxiliary switch Contactors + overload relay Direct-on-line start load feeders Reversing feeders dapters for SIRIUS size S3 Motor starter protectors/circuit breakers dapters for 3VF circuit breakers 3VF3 3VF4 -- 3VF5 -- dapters for 3VL circuit breakers 3VL1 3VL2 3VL3 -- 3VL4 -- dapters for 3K switch disconnectors 3K52 -- 3K53 -- 3K55 -- 3K57 -- 3K58 -- dapters for 3NP fuse switch disconnectors 3NP50 60 -- 3NP52 -- 3NP53 -- 3NP54 -- Standard -- Not available 6 Siemens 2009

3K, 3KE, 3LD Switch Disconnectors 3K, 3KE Switch Disconnectors up to 1000 General data Overview 1 2 3 NSE0_01931a 4 5 6 7 1 uxiliary switch (3SB for 3K; 3KX for 3KE) 2 IP20 terminal cover (Operator side) 3 3K switch disconnector 4 rcing contacts (only for 3KE) 5 Extension shaft 6 8UC7 door-coupling rotary operating mechanism in standard version (ti-grey) or EMERGENCY-STOP version (red/yellow). 7 8UC9 knob for fixed mounting in standard version (black) or EMERGENCY-STOP version (red/yellow). ll components from the switch to the actuator are provided with non-interchangeability features. Design For the 3K switch disconnectors, complete kits for standard and EMERGENCY-STOP application are available for installation in the side and rear panels of control cabinets. changeover operating mechanism is available for the use of 2 switch disconnectors in the 3KE series as load changeover switches. n operating linkage permits simultaneous switching of two 3KE switch disconnectors with identical or different rated operational currents. Identical accessories for 3K switch disconnectors and for 3KL and 3KM switch disconnectors with fuses simplify stock keeping. Siemens 2009 7

3K, 3KE, 3LD Switch Disconnectors 3K, 3KE Switch Disconnectors up to 1000 General data Technical specifications Permissible mounting positions 90 90 90 10 180 180 180 NSE0_00181a NSE0_00182a 3KE 3K Standards IEC 60947-1, IEC 60947-3 Type 3K50 3K51 3K52 1) 3K53 1) 3K55 1) 3K57 1) 3K58 1) Rated uninterrupted current I u 63 80 125 160 250 400 630 3) 2) Conventional free-air thermal current I th 63 80 125 160 250 400 630 3) Rated insulation voltage U i V 690 690 1000 1000 1000 1000 1000 Rated impulse voltage U imp kv 6 6 8 8 8 8 8 Rated operational voltage U e C 50 Hz/60 Hz V 690 DC V 440 (3 conducting paths series-connected) V 220 (2 conducting paths series-connected) V 110 (1 conducting path) Rated short-circuit making capacity I cm k 220 220 220 220 176 176 105 with upstream fuses 4) t C 50 Hz/60 Hz 690 V Rated conditional short-circuit current (peak k 100 100 100 100 80 80 50 with upstream fuses 4) t C 50 Hz/60 Hz 690 V Max. rated current I n of the fuses (rms 63 80 160 160 400 400 630 Permissible let-through current of the fuses k 8 10 17 17 30 5) 30 5) 40 5) Maximum permissible let-through I 2 t value k 2 s 55 55 223 223 1000 1000 2600 Permissible let-through current k 7 8 8 15 25 25 32 of an upstream circuit breaker t C 50 Hz/60 Hz 690 V Rated short-circuit making capacity without fuses (peak k 7 7 7 9 20 25 35 t C 50 Hz/60 Hz 690 V (peak Switching capacity (infeed from the top or bottom) t 400 V C Breaking current I c (p.f. = 0.35) (rms 500 650 1000 1280 2000 3200 5040 Rated operational current I e at C-21, C-22, C-23 63 80 125 160 250 400 630 6) Motor switching capacity C-23 kw 30 40 65 80 132 200 350 t 500 V C Breaking current I c (p.f. = 0.35) (rms 500 640 1000 1280 2000 3200 3200 Rated operational current I e at C-21, C-22 63 80 125 160 250 400 630 C-23 63 80 125 160 250 400 400 Motor switching capacity C-23 kw 40 50 90 110 185 280 280 t 690 V C Breaking current I c (p.f. = 0.35) (rms 500 500 1000 1280 2000 3200 3200 Rated operational current I e at C-21, C-22 63 80 125 160 250 400 630 C-23 63 63 125 160 250 400 400 Motor switching capacity C-23 kw 50 50 110 150 220 375 375 t 440 V DC (3 conducting paths series-connected) 7) Breaking current I c (L/R = 15 ms) 250 260 500 640 1000 8) 1600 1600 Rated operational current I e at DC-23 63 63 125 160 250 9) 400 400 Rated short-time current I cw (1 s current) k 2.5 2.5 3.2 3.2 8 11 15 (rms Permissible load Depending on the ambient temperature for open-type installation in control panels (e. g. 8N1) in control cubicles or control racks at 35 C 63 80 125 160 250 400 630 40 C 63 80 125 160 250 400 620 45 C 63 80 125 160 250 400 600 50 C 63 80 125 160 250 400 580 55 C 63 80 125 160 250 400 560 60 C 63 80 125 160 250 400 550 8 Siemens 2009

3K, 3KE, 3LD Switch Disconnectors 3K, 3KE Switch Disconnectors up to 1000 General data Standards IEC 60947-1, IEC 60947-3 Type 3K50 3K51 3K52 1) 3K53 1) 3K55 1) 3K57 1) 3K58 1) Permissible ambient temperature C -25... +55 for operation 3) C -50... +80 when stored Mechanical endurance Operating 15 000 15 000 15 000 15 000 12 000 12 000 12 000 cyc- les Required operating torque Nm 3 3 7.5 7.5 16 16 16 Degree of protection IP00/IP20 (from the operator side, with busbar and terminal covers) Power loss of the switch disconnector at I th W 7 12 22 22 33 72 170 Main conductor connections Busbar systems, max. dimensions (w x t) mm x mm 25 x 9 25 x 9 45 x 10 45 x 10 40 x 12 40 x 12 40 x 15 Cable lug, max. conductor cross-section (stranded) mm 2 35 35 70 120 150 2 x 150 or 2 x 240 1x240 Tightening torque Nm 6... 7.5 6... 7.5 7... 10 18... 22 35... 45 35... 45 35... 45 Terminal screws M6 M6 M6 M8 M10 M10 M10 Protective conductor connections Flat bars mm x mm -- -- -- -- 20 x 2.5 20 x 2.5 20 x 2.5 Cable lug, max. conductor cross-section (stranded) mm 2 -- -- -- -- 70 120 120 uxiliary switch 1 NO + 1 NC (accessories) Max. number to be plugged 1 1 2 2 2 2 2 Rated operational current I e at C 50 Hz/60 Hz I e /C-12 10 I e /C-15 at U e = 220 V/230 V 6 I e /C-15 at U e = 380 V/400 V 4 I e /C-15 at U e = 500 V 2.5 I e /C-15 at U e = 690 V 21.2 Rated operational current I e at DC I e /DC-13 at U e = 24 V 10 I e /DC-13 at U e = 48 V 4 I e /DC-13 at U e = 110 V 1.2 I e /DC-13 at U e = 220 V 0.4 I e /DC-13 at U e = 440 V 0.2 Connection Solid mm 2 2 x (1... 2.5) Finely stranded with end sleeve mm 2 2 x (0.5... 1.5) Weight Complete version kg 1.450 1.450 2.400 2.400 5.400 5.500 6.100 Basic version kg 0.950 0.950 1.900 1.900 4.500 4.600 5.200 1) Technical specifications for approval on request. 2) Configuring note: max. permissible operating temperature at connections 100 C. 3) With 3K58 for operation -25 C... +35 C, 570 at 55 C. 4) Only with 3N38, 3N32 or 3ND18, 3ND12 fuses (otherwise only 105 k/50 k). 5) 3ND1 switchgear protection fuse. 6) C-23B. 7) Or 220 V DC (L1 and L3 series-connected) or 110 V DC (one conducting path) at DC-23. 8) t 440 V L/R = 4 ms, at 220 V L/R = 15 ms. 9) t 440 V DC-22, at 220 V DC-23. Siemens 2009 9

3K, 3KE, 3LD Switch Disconnectors 3K, 3KE Switch Disconnectors up to 1000 General data Standards IEC 60947-1, IEC 60947-3, VDE 0660 Part 107 Type 3KE42 3KE43 3KE44 3KE45 Rated uninterrupted current I u 250 400 630 1000 Rated insulation voltage U i V 1000 C, 1200 DC Rated impulse voltage U imp kv 8 8 8 8 Rated operational voltage U e C 50 Hz/60 Hz V 690 DC V 440 (3 conducting paths series-connected) V 220 (2 conducting paths series-connected) Rated short-circuit making capacity I cm t50hz/60hz 690V C k (peak k (peak (rms 35 35 60 60 Rated short-circuit making capacity with upstream fuses 105 105 105 84 t50hz/60hz 690V C Rated conditional short-circuit current 50 50 50 40 with upstream fuses t50hz/60hz 690V C Maximum permissible let-through I 2 t value k 2 s 2150 2150 5400 19000 Permissible let-through current of an upstream circuit breaker t50hz/60hz 690V C k (peak 35 35 60 60 Max. rated current I n of the fuses 400 400 630 1000 Permissible let-through current of the fuses k (peak 38 38 60 75 Switching capacity (infeed from the top or bottom) t 400 V C Breaking current I c (p.f. = 0.35) (rms 1000 1000 2520 2520 Rated operational current I e at C-21 250 400 630 1000 C-22 250 330 630 800 C-23 125 125 315 315 t 500 V C Breaking current I c (p.f. = 0.35) (rms 1000 1000 2520 2520 Rated operational current I e at C-21 250 400 630 1000 C-22 250 330 630 800 C-23 125 125 315 315 t 690 V C Breaking current I c (p.f. = 0.35) (rms 1000 1000 2520 2520 Rated operational current I e at C-21 250 400 630 1000 C-22 250 330 630 800 C-23 125 125 315 315 t 440 V DC (3 conducting paths series-connected) Breaking current I c (L/R = 5 ms) 1000 1000 2520 2520 Rated operational current I e at DC-21 250 400 630 1000 DC-22 250 250 630 630 Rated short-time current I cw (1 s current) 12.5 12.5 21 21 (rms Permissible load Depending on the ambient temperature for open-type installation in control panels (e. g. 8N1) in control cubicles or control racks at 35 C 250 400 630 1000 40 C 250 400 630 960 45 C 250 400 630 930 50 C 250 400 630 890 60 C 240 380 600 810 For enclosed installation, e. g. in 8HP systems See Catalog "8HP System". Order No. E20001-8ZX1012-0HP54-5B1 Permissible ambient temperature C -25... +55 for operation C -50... +80 when stored Mechanical endurance Operating 10 000 cyc- les Degree of protection IP00 Required operating torque Nm 15 15 24 24 10 Siemens 2009

3K, 3KE, 3LD Switch Disconnectors 3K, 3KE Switch Disconnectors up to 1000 General data Standards IEC 60947-1, IEC 60947-3, VDE 0660 Part 107 Type 3KE42 3KE43 3KE44 3KE45 Required operating torque for changeover operating mechanism With interruption Nm 20 20 30 30 Without interruption Nm 35 35 55 55 Power loss of the switch disconnector at I th W 15 33 78 180 Main conductor connections Busbar systems, max. dimensions (w x t) mm x mm 25 x 10 25 x 10 2 x 40 x 10 2 x 40 x 10 Cable lug, max. conductor cross-section (stranded) mm 2 2 x 150 2 x 150, 1 x 240 2 x 240 2 x 240 uxiliary switch 1 NO + 1 NC (accessories) Rated insulation voltage U i V 500 Rated operational current I e (same potential at contacts) at C 50 Hz/60 Hz I e /C-1 at U e = 500 V 10 I e /C-11 at U e = 230 V 6 Rated operational current I e (same potential at contacts) at DC I e /DC-11 at U e = 24 V 10 I e /DC-11 at U e = 220 V 0.4 Connection Solid mm 2 2 x 2.5 Finely stranded with end sleeve mm 2 2 x 1.5 Short-circuit protection (tested as per DIN VDE 0660 with 6 TDz, 10 Dz or 10 G-type m.c.b. 1000 ) Schematics Internal circuit diagram for 3K Internal circuit diagram for 3KE (for 3K50 and 3K51, only one auxiliary switch possible; 4th pole is possible as main contact) Internal circuit diagram for 3K and 3KE (auxiliary switch not included in scope of supply) Use for DC voltage at DC-23 440 V 5 - # & 2! # Circuit diagram for changeover switch with interruption " $ Siemens 2009 11

D 3K, 3KE, 3LD Switch Disconnectors 3K, 3KE Switch Disconnectors up to 1000 Floor mounting Dimensional drawings 3K50, 63, 3K51, 80, 3-pole 3K50 and 3K51: dimensional drawing for 4-pole version corresponds to dimensional drawing for 3K52 without shaft, without operating mechanism 3K50, 63, 3K51, 80, 3-pole 3K50 and 3K51: dimensional drawing for 4-pole version corresponds to dimensional drawing for 3K52 with shaft and 8UC7 operating mechanism 3K50, 3K51 Shaft (profile) engaged length: min. 70 mm max. 150 mm a Shaft length Max. 380 300; unchanged shaft from 8UC71 Min. 175 175-80 ; shortened shaft from 8UC71 175... 380 a -80 3K52, 125 3K53, 160 3K50, 3K51, 4-pole without shaft, without operating mechanism 3K52, 125 3K53, 160 3K50, 3K51, 4-pole with shaft and 8UC7 operating mechanism 4th pole 3KX3 523-0 for 3K53, 3K52 " $ $ # Type c h n 5 - % '? 3K52 3K53 15 20 91 105 106 125 4th pole 15 91 106 3K52, 3K53 Shaft (profile) engaged length: min. 90 mm max. 143 mm a Shaft length Max. 350 300; unchanged shaft from 8UC72 Min. 165 165-50 ; shortened shaft from 8UC72 165... 350 a -50 Type c d e g h i l n 3K52 3K53 15 20 M6 20 M8 25 37 39 42 39.5 91 105 3 3.5 6.6 9 106 125 4th pole 15 M6 20 -- 48 91 3 6.6 106?! # 3K55, 250, 3K57, 400 without shaft, without operating mechanism 3K55, 250, 3K57, 400, 3K58, 630 with shaft and 8UC7 operating mechanism 3K58, 630 without shaft, without operating mechanism 3K55, 3K57, 3K58 Shaft (profile) engaged length: min. 170 mm max. 205 mm 3K58 a Shaft length Max. 335 300; unchanged shaft from 8UC73 Min. 230 230-35 ; shortened shaft from 8UC73 230... 335 a -35 4th pole 3KX3 553-0 for 3K55, 3K57, 3K58 Type a b c 3K55, 3K57 3K58 40 38 4 6 M10 30 M10 35 4th pole 80 4 M10 30 12 Siemens 2009

f f t t 3K, 3KE, 3LD Switch Disconnectors 3K, 3KE Switch Disconnectors up to 1000 Floor mounting 3KE4 FRONT OPERTING MECHNISM with handle 14,5 w 128 24 22,5 32 x 90 e 46,5 m 3KX2 210-0H Coupling socket b d n g 7 152 k NSE0_00318a 8 c h 34,5 187 p 133 z l 254 y 5 12 3KE4 Rear rotary operating mechanism without handle Keep this Keep this space free m 1 space free (arc exit) b (arc exit) d 14,5 63,5 y x 3KX2 210-0H 19 v c 12 4,5 40 92 32 h1 z l o p 1 w 1 5 20 11 7 29 7 8 195 n 1 e g 12 90 128 152 k NSE0_00319b Caution! Must not be used as a drive. 68 97 s u 209 100 Type b c d e f g h h 1 k l m m 1 n n 1 o p p 1 s t u v w w 1 x y z 3KE42 155 170 140 25 200 40 60 92 175 M10 30 194 194 129 121 4 150 182 15 -- 105 140 170 172 M10 18 50 50 3KE43 155 170 140 25 200 47 60 92 175 M10 30 194 194 129 121 4 150 182 15 -- 105 140 170 172 M10 18 50 50 3KE44 170 192 155 40 278 55 65 97 238 M12 35 209 208 144 136 5 161 193 23 3.5 121 200 172 172 M10 18 -- -- 3KE45 170 192 155 40 290 65 68 100 250 M12 50 209 208 144 136 8 161 193 23 3.5 121 200 172 172 M12 25 -- -- 3KE4. 30-0E with shaft and 8UC7 operating mechanism Type r Shaft length q 3KE42, 3KE43 Max. 433 300; unchanged shaft from 8UC73 140 Min. 200 67; shortened shaft from 8UC73 140 200... 433 r 133 140 3KE44, 3KE45 Max. 433 300; unchanged shaft from 8UC74 140 Min. 210 77; shortened shaft from 8UC74 140 210... 433 r 133 140 3KX2 210 changeover operating mechanism 3KX2 250-1 operating linkage Version For type a b c d e f q With interruption Without interruption 3KE42, 3KE43 3KE44 3KE45 3KE42, 3KE43 3KE44 3KE45 352 367 367 352 367 367 140 155 155 140 155 155 427 442 442 417 432 432 92.5 92.5 92.5 74.5 74.5 74.5 115 115 115 97 97 97 45 45 55 35 35 35 200 200 200 200 200 200 Siemens 2009 13

3K, 3KE, 3LD Switch Disconnectors 3LD Main and EMERGENCY-STOP Switches up to 125 General data Overview 3 7 8 2 6 1 3 5 NSG0_00112a 4 1 4th contact (N conductor) 2 N or PE/ground terminal, continuous 3 uxiliary switch 1 NO + 1 NC 4 Rotary operating mechanism, red/yellow 5 Rotary operating mechanism, black 6 Front plate, English/German 7 Terminal cover, three-pole 8 Terminal cover, single-pole 14 Siemens 2009

3K, 3KE, 3LD Switch Disconnectors 3LD Main and EMERGENCY-STOP Switches up to 125 General data Design Construction of the contacts Each switch has three adjacent contact elements 1). fourth leading contact element for switching the N conductor, a continuous PE/ground terminal, an auxiliary switch (1 NO or 1 NC) can be fitted to each side of the switch. The auxiliary switches operate as leading contacts on opening. On opening, the NO contact opens before the main contacts, so that a contactor carries the switching capacity in the circuit and the maintenance or safety switch switches at zero current. On closing, the auxiliary switch switches later than or at the same time as the main contacts. Switch construction Construction of rotary operating mechanisms The rotary operating mechanisms of the switches for front or floor mounting are mounted on control cabinet doors, front panels or side panels with four-hole or center-hole mounting with a standard diameter of 22.5 mm and operated from the outside. In their Off position, they can be locked with up to three padlocks with a hasp thickness of 8 mm. Controls with defeatable doorcoupling rotary operating mechanism are available in addition. Switch position indicator: The switch position is clearly marked with direction arrows and an "O" for OFF and a "I" for ON at the front. Switches for front mounting: The switches for front mounting are connected directly to the rotary operating mechanism through the fixing screws or - in the case of center-hole mounting - a special-purpose coupling. Switches for floor mounting: The switches for floor mounting are snapped onto 35 mm standard mounting rails according to EN 60715 or screwmounted on mounting plates. The actuators are connected to the lower section of the switch through a door coupling, which can be released in its zero position, and a 300 mm long switch shaft. When the control cabinet door is open, the switch can be protected against inadvertent operation by removing the switch shaft from the lower section of the switch. The mounting depth can be adapted to individual requirements by adjusting the switch shaft length. Switches for distribution board mounting: The switches for distribution board mounting are suited for operation in switchboards and for switching inside control cabinets or distributors. They have cap and mounting dimensions to DIN 43880 and can be fitted under the same cover together with miniature circuit breakers. The selector knobs can be locked in their OFF position with up to 2 padlocks with a hasp thickness of 6 mm. Switches in molded-plastic enclosure: For surface mounting of individual main control and EMERGENCY-STOP switches, molded plastic-enclosed switches to degree of protection IP65 are used. The actuators can be locked in their OFF position with three padlocks with a hasp thickness of 8 mm. The molded-plastic enclosures each contain an N and/or a PE/ground terminal. 1) 16 versions have four contact elements; 3-pole changeover switches and 6-pole main control switches have six contact elements. 3LD2 203-0TK5 switch for front mounting with rotary operating mechanism 3LD2 122-7UK01 3-pole changeover switch for front mounting with selector knob 3LD2 213-0TK5 switch for floor mounting with rotary operating mechanism and door coupling 3LD2 264-0TB5 switch in molded-plastic enclosure 3LD2 222-0TK1 switch for front mounting with selector knob 3LD2 103-3VK53 6-pole switch for front mounting with rotary operating mechanism 3LD2 530-0TK11 switch for distribution board mounting with selector knob 3LD2 217-1TL13 switch for floor mounting with rotary operating mechanism and defeatable door coupling Siemens 2009 15

3K, 3KE, 3LD Switch Disconnectors 3LD Main and EMERGENCY-STOP Switches up to 125 General data Technical specifications Standards DIN VDE 0660, IEC 60947 Switches Type 3LD2 0 3LD2 1 3LD2 2 3LD2 5 3LD2 7 3LD2 8 Number of contacts 3/4 3/4 3/4 3/4 3/4 3/4 Rated insulation voltage U i Rated operational voltage U e Rated frequency Rated impulse withstand voltage U imp Rated short-time withstand current (1 s current, rms Short-circuit protection, max. back-up fuse (gl) V V C Hz kv 690 690 50... 60 6 340 20 690 690 50... 60 6 640 25 690 690 50... 60 6 640 40 690 690 50... 60 6 1260 63 690 690 50... 60 6 2000 100 Rated uninterrupted current I u 16 25 32 63 100 125 C-21 load-break switch Rated operational current I e 16 25 32 63 100 125 C-3 motor load switches In-service switching of individual motors C-23 main control switch Repair switch frequent, but not in-service switching of individual motors Rating t 220 V... 240 V t 380 V... 440 V t 660 V/690 V Rating t 220 V... 240 V t 380 V... 440 V t 660 V/690 V kw kw kw kw kw kw Power loss per conducting path at I e W 0.5 1.1 1.8 4.5 7.5 12 3.0 5.5 5.5 4.0 7.5 7.5 4.0 7.5 7.5 5.0 9.5 9.5 5.5 9.5 9.5 6.0 11.5 11.5 11.0 18.5 15.0 11.0 22.0 18.5 18.5 30.0 22.0 18.5 37.0 30.0 690 690 50... 60 6 2000 125 Touch protection acc. to IEC 61140 Yes Yes Yes Yes Yes Yes Endurance Operating 100 000 100 000 100 000 100 000 100 000 100 000 Mechanical cycles Switching frequency 1/h 50 50 50 50 50 50 Permissible ambient temperature C -25... +55-25... +55-25... +55-25... +55-25... +55-25... +55 Isolating features Up to 690 690 690 690 690 690... V Main control and EMERGENCY-STOP switch characteristics 1) Yes Yes Yes Yes Yes Yes Conductor cross-sections for main conductors Connection type Terminals Solid or stranded mm 2 1... 6 1.5... 16 1.5... 16 2.5... 35 4... 50 4... 50 Finely stranded with end sleeve (max.) mm 2 4 10 10 16 35 35 uxiliary switches Rated insulation voltage U i V 500 500 500 500 500 500 Rated operational voltage U e V C 500 500 500 500 500 500 Rated uninterrupted current I u 10 10 10 10 10 10 Rated operational current I e C-15 t 120 V 6 6 6 6 6 6 t 220 V... 240 V 3 3 3 3 3 3 t 380 V... 415 V 1.8 1.8 1.8 1.8 1.8 1.8 t 500 V 1.4 1.4 1.4 1.4 1.4 1.4 Short-circuit protection, auxiliary switch, max. back-up fuse (gl/gg) 10 10 10 10 10 10 Conductor cross-sections for auxiliary conductors Connection type Terminals Solid or stranded mm 2 2 (0.75... 2.5) 1 4 Finely stranded with end sleeve mm 2 2 (0.75... 1.5) 1 x 2.5 2 (0.75... 2.5) 1 4 2 (0.75... 1.5) 1 x 2.5 2 (0.75... 2.5) 1 4 2 (0.75... 1.5) 1 x 2.5 2 (0.75... 2.5) 1 4 2 (0.75... 1.5) 1 x 2.5 2 (0.75... 2.5) 1 4 2 (0.75... 1.5) 1 x 2.5 Torque for terminal Nm 0.8 0.8 0.8 0.8 0.8 0.8 22.0 37.0 30.0 22.0 45.0 37.0 2 (0.75... 2.5) 1 4 2 (0.75... 1.5) 1 x 2.5 Standards UL/CS Switches Type 3LD2 0 3LD2 1 3LD2 2 3LD2 5 3LD2 7 3LD2 8 Rated operational voltage U e V C 600 600 600 600 600 600 Rated uninterrupted current I u 10 20 30 60 100 125 Current rating 600 600 600 -- -- -- Pilot duty P 600 P 600 P 600 Conventional thermal current I th 16 25 32 63 100 125 Maximum rated power (C-3) 3 120 V HP 1 3 3 5 10 15 C motors 40 Hz... 60 Hz 240 V HP 3 7.5 10 15 30 40 (HP = PS) 480 V HP 7.5 10 20 40 60 75 600 V HP 10 15 30 50 75 100 1 120 V HP 0.5 2 2 3 -- -- 240 V HP 1.5 3 3 10 -- -- Conductor cross-sections Cu cable WG 18... 10 14... 8 14... 8 14... 6 12... 1 12... 1 Torque Nm 1.5... 2 2... 2.5 2... 2.5 2.5... 3 2.5... 3 2.5... 3 With appropriate operating mechanisms according to EN 60664-1 (see Catalog LV 1). 16 Siemens 2009

3K, 3KE, 3LD Switch Disconnectors 3LD Main and EMERGENCY-STOP Switches up to 125 Front mounting Dimensional drawings Switches for center-hole mounting with rotary operating mechanism 3LD2.54, 3LD2 555 N L K C Drilling diagram M B F G NSG0_00206 3,2 24,1 max 5,5 mm For 3LD2 0 Base element 4-pole 22,5 Type B C F G K L M 1) N 1) 3LD2 054 67 67 48 50 38 37 74 17 47 3LD2 154/3LD2 254 67 67 46 55 44 37 74 17 47 3LD2 555 90 90 60 64 50 46 81 17 47 1) For additional inscription label see ccessories. Switches for four-hole mounting with rotary operating mechanism 3LD2.03, 3LD2.04 N M L K C Drilling diagram 1 B G F NSG0_00207 1 D max. 5,5 mm Sealing plate behind masking plate Please observe sealing position of the shaft seal For 3LD2 0 Base element 4-pole d Type B 1 C D d F G K L M 1) N 1) 3LD2 003 67 67 48 48 10 5.0 50 38 37 50 17 47 3LD2 103 67 67 48 46 10 5.0 55 44 37 50 17 47 3LD2 504 90 90 48 60 10 5.0 64 50 46 59 17 47 3LD2 704/3LD2 804 90 90 48 71 10 5.0 83 54 46 61 17 47 1) For additional inscription label see ccessories. Switches for center-hole mounting with selector knob 3LD2.50 N M B F G L K C NSG0_00208 Drilling diagram 3,2 24,1 max 5,5 mm For 3LD2 0 Base element 4-pole Type B C F G K L M 1) N 1) 3LD2 050 49 49 48 50 38 34 74 17 47 3LD2 150/3LD2 250 49 49 46 55 44 34 74 17 47 1) For additional inscription label see ccessories. Siemens 2009 17

3K, 3KE, 3LD Switch Disconnectors 3LD Main and EMERGENCY-STOP Switches up to 125 Front mounting Switches for four-hole mounting with selector knob 3LD2.22 N L K C Drilling diagram M G NSG0_00209 1 D B F 1 max 5,5 mm Sealing plate behind masking plate Please observe sealing position of the shaft seal For 3LD2 0 Base element 4-pole d Type B 1 C D d F G K L M 1) N 1) 3LD2 022 49 49 36 48 10 5.0 50 38 34 50 17 47 3LD2 122/3LD2 222 49 49 36 46 10 5.0 55 44 34 50 17 47 1) For additional inscription label see ccessories. Switches for four-hole mounting with rotary operating mechanism 3LD2 103-.V, 3LD2 203-.V..., 3LD2 504-.V N L K C Drilling diagram M 1 G D B F max. 5,5 mm Sealing plate behind masking plate Please observe sealing position of the shaft seal NSG0_00215 1 d Type B 1 C D d F G K L M 1) N 1) 3LD2 103-.V... 67 67 48 92 10 5.0 55 44 37 50 17 47 3LD2 203-.V... 67 67 48 92 10 5.0 55 44 37 50 17 47 3LD2 504-.V... 90 90 68 121 10 5.0 64 50 46 59 17 47 1) For additional inscription label see ccessories. Switches for four-hole mounting with selector knob 3LD2 122-.V N L K C Drilling diagram M 1 G D B F max 5,5 mm Sealing plate behind masking plate Please observe sealing position of the shaft seal NSG0_00216 1 d Type B 1 C D d F G K L M 1) N 1) 3LD2 122-.V... 49 49 36 92 10 5.0 55 44 32 50 17 47 1) For additional inscription label see ccessories. 18 Siemens 2009

3K, 3KE, 3LD Switch Disconnectors 3LD Main and EMERGENCY-STOP Switches up to 125 Front mounting Changeover switches 3LD2 123-7U, 3LD2 223-7U, 3LD2 524-7U, 3LD2 724-7U N L K C Drilling diagram M 1 B F G NSG0_00217 1 D d max 5,5 mm Sealing plate behind masking plate Please observe sealing position of the shaft seal Type B 1 C D d F G K L M 1) N 1) 3LD2 123-7U... 67 67 48 92 10 5.0 28 46 34 63.5 17 47 3LD2 223-7U... 67 67 48 92 10 5.0 28 46 34 63.5 17 47 3LD2 524-7U... 92 92 68 121 10 5.5 32 53 40 73 17 47 3LD2 724-7U... 92 92 68 141 10 5.5 42 68 40 75 17 47 1) For additional inscription label see ccessories. Siemens 2009 19

F 3K, 3KE, 3LD Switch Disconnectors 3LD Main and EMERGENCY-STOP Switches up to 125 Floor mounting Dimensional drawings Switches for floor mounting with detachable rotary operating mechanism (four-hole mounting) 3LD2.13, 3LD2 14. N M X = L + 52 mm L1 79 K C Driling diagram Door 1 Base B1 B G F 5 L NSG0_00210 1 D d B2 e Type B 1 B1 B2 C D d e F G K L L1 M 1) N 1) X min 3LD2 013 67 67 48 22 60 48 10 5.0 4.5 50 38 37 330 58 17 47 138 3LD2 113/3LD2 213 67 67 48 22 60 46 10 5.0 4.5 55 44 37 330 58 17 47 138 3LD2 514 90 90 48 25 70 60 10 5.5 5.5 64 50 46 338 68 17 47 148 3LD2 714/3LD2 814 90 90 48 25 90 71 10 5.5 5.5 83 54 46 340 70 17 47 150 1) For additional inscription label see ccessories. Switches for floor mounting with detachable rotary operating mechanism (center-hole mounting) 3LD2.44, 3LD2.45 N 5 B M G F X = L + 74 mm L1 101 K L C NSG0_00211 3,2 Drilling diagram Door 22,5 24,1 B2 Base B1 e Type B B1 B2 C e F G K L L1 M 1) N 1) X min 3LD2 044 67 67 22 60 48 4.5 50 38 37 330 58 17 47 160 3LD2 144/3LD2 244 67 67 22 60 46 4.5 55 44 37 330 58 17 47 160 3LD2 545 90 90 25 70 60 5.5 64 50 46 338 68 17 47 170 1) For additional inscription label see ccessories. Switches for floor mounting with detachable rotary operating mechanism (four-hole mounting) 3LD2 113-.V N M B G X = L + 52 mm L1 79 K C NSG0_00218 1 Drilling diagram Door 1 D B2 Base B1 d 5 L e Type B 1 B1 B2 C D d e F G K L L1 M 1) N 1) X min 3LD2 113-.V... 67 67 48 22 60 92 10 5.0 4.5 55 44 37 330 58 17 47 138 1) For additional inscription label see ccessories. 20 Siemens 2009

3K, 3KE, 3LD Switch Disconnectors 3LD Main and EMERGENCY-STOP Switches up to 125 Distribution board mounting Dimensional drawings Switches for distribution board mounting with selector knob 3LD2.30 45 L K1 K C B F NSG0_00212 5 Type B C F K K1 L 3LD2 030 53 45 48 50 41 14 37 3LD2 130 53 45 46 55 41 14 37 3LD2 230 53 45 46 55 41 14 37 3LD2 530 64 45 60 64 43 16 44 3LD2 730 71 45 71 83 47 19 44 3LD2 830 71 45 71 83 47 19 44 1) For additional inscription label see ccessories. Siemens 2009 21

3K, 3KE, 3LD Switch Disconnectors 3LD Main and EMERGENCY-STOP Switches up to 125 Molded-plastic enclosures Dimensional drawings Switches with molded-plastic enclosure with rotary operating mechanism Metric screwed glands 3LD2.64, 3LD2.65, 3LD2.66 K H M Drilling diagram 3LD2.64 3LD2.65 Drilling diagram 3LD2.66 1 C F K B B2 D E B1 N B1 B1 NSG0_00213 d G Type B 1 B1 B2 C d D E F G H K M N 3LD2.64-...5. 100 140 -- 152 164 46 4.5 4 x M25 24 -- 4 x M20 81 67 36 2 x M20. 2 x M40 3LD2.65-...5. 146 176 -- 188 199 66 4.5 4 x M32/40 37 -- 4 x M20 104 90 45 2 x M20, 2 x M40 3LD2.66-...5. 212 302 189 238 302 84 6.5 4 x M50/63 57 2 x M20 4 x M20 136 90 45 2 x M20, 2 x M50 3LD2 566-.V... 212 302 189 238 302 84 6.5 4 x M32/40 57 2 x M20 4 x M20 136 90 45 2 x M20, 2 x M50 Switches in molded-plastic enclosure with selector knob 3LD2.6.-7U K H M Drilling diagram 3LD2.65 Drilling diagram 3LD2.66 1 C F D K B E B2 B1 N B1 B1 NSG0_00220 d G Type B 1 B1 B2 C d D E F G H K M N 3LD2 165-7U... 146 176 -- 188 199 66 4.5 4 x M32/40 37 -- 4 x M20 104 67 32 2 x M20. 2 x M40 3LD2 265-7U... 146 176 -- 188 199 66 4.5 4 x M32/40 37 -- 4 x M20 104 67 32 2 x M20, 2 x M40 3LD2 566-7U... 212 302 189 238 302 84 6.5 4 x M32/40 57 2 x M20 4 x M20 136 90 45 2 x M20, 2 x M50 3LD2 766-7U... 212 302 189 238 302 84 6.5 4 x M50/63 57 2 x M20 4 x M20 136 90 45 2 x M20, 2 x M50 22 Siemens 2009

3K, 3KE, 3LD Switch Disconnectors 3LD Main and EMERGENCY-STOP Switches up to 125 ccessories Dimensional drawings Front mounting 3LD9 2.0-0B 4th contact element (N conductor) for front mounting, leading switch-on, delayed switch-off Front and floor mounting 3LD9 2.4-1B, 3LD9 2.4-3B rotary operating mechanism for four-hole mounting black, red/yellow G C B B NSE0_00934 N NSE0_00928a N C Type B C 3LD9 224-1B 67.0 67.0 37.0 3LD9 224-3B 67.0 67.0 37.0 3LD9 284-1B 90.0 90.0 46.0 3LD9 284-3B 90.0 90.0 46.0 Type B C G 3LD9 220-0B 54.5 40.5 15.5 31.5 3LD9 250-0B 64.5 47.0 20.0 37.0 3LD9 280-0B 83.5 44.0 23.0 20.0 3LD9 2.4-1D, 3LD9 2.4-3D rotary operating mechanism for center-hole mounting black, red/yellow 3LD9 2.0-2B N or PE/ground terminal for front mounting, leading switch-on, delayed switch-off G NSE0_00935 B C B Type B C 3LD9 224-1D 67.0 67.0 37.0 3LD9 224-3D 67.0 67.0 37.0 3LD9 284-1D 90.0 90.0 46.0 3LD9 284-3D 90.0 90.0 46.0 N NSE0_00929a N C 3LD9 2.1-2 terminal cover as additional touch protection for snap fitting at top or bottom, 1-pole Type B C G 3LD9 200-2B 50.0 40.0 13.0 31.0 3LD9 220-2B 54.5 40.5 15.5 31.5 3LD9 250-2B 64.5 47.0 20.0 37.0 3LD9 280-2B 83.5 44.0 23.0 20.0 - C NSE0_00936 3LD9 286-1, 3LD9 286-4 inscription label German/English, neutral MIN SWITCH HUPTSCHLTER NSE0_00933a 5 17 47 Type B C 3LD9 201-2 34.5 15.0 10.0 3LD9 221-2 34.5 20.0 15.0 3LD9 251-2 40.5 21.5 20.0 3LD9 281-2 45.0 17.5 23.0 B Siemens 2009 23

3K, 3KE, 3LD Switch Disconnectors 3LD Main and EMERGENCY-STOP Switches up to 125 ccessories 3LD9 2.1-. terminal cover as additional touch protection for snap fitting at top or bottom, 1-pole - NSE0_00937 3LD9 200-5.. auxiliary switch NSJ0_00005 50 B C 11 32 Type B C 3LD9 201-1 34.5 15.0 46.0 3LD9 221-0 34.5 20.0 46.0 3LD9 251-0 40.5 21.5 60.0 Floor and distribution board mounting 3LD9 2.0-0C 4th contact element (N conductor) for front mounting, leading switch-on, delayed switch-off G N N C B NSE0_00938a Type B C G 3LD9 220-0C 54.5 40.5 15.5 31.5 3LD9 250-0C 64.5 47.0 20.0 37.0 3LD9 280-0C 83.5 44.0 23.0 20.0 3LD9 2.0-2C N or PE terminal through-out G N N C B NSE0_00939a Type B C G 3LD9 200-2C 50.0 40.0 13.0 31.0 3LD9 220-2C 54.5 40.5 15.5 31.5 3LD9 250-2C 64.5 47.0 20.0 37.0 3LD9 280-2C 83.5 44.0 23.0 20.0 24 Siemens 2009

3KL, 3KM, 3NJ6 Switch Disconnectors with Fuses 3KL Switch Disconnectors with Fuses up to 800 General data Overview 7 2 NSE0_01557a 4 1 5 6 7 9 3 7 3KL or 3KM basic device Plug-in contact strip for 3KM Fuses, optionally BS-88 or LV HRC fuses Terminal cover, IP20 (vertical to operator side) Coupling driver with extension shaft Standard products from the Siemens 3SB1 range are used as auxiliary switches. Single-pole terminal cover from 63 to 630, IP20 (vertical to operator side) 8 Optional 8UC9 knob for fixed mounting in standard version (black) or EMERGENCY-STOP version (red), or 9 8UC7 door-coupling rotary operating mechanism in standard version (ti-grey) or EMERGENCY-STOP version (red/yellow) 3 ll components from the switch to the actuator are provided with non-interchangeability features. Design ll switch disconnectors feature double contact interruption and an isolating distance. s a result, the fuses of the switch disconnectors are de-energized in the OFF position. The 3KM switch disconnectors with fuses also feature an isolating plug connector. This facilitates mounting and contact establishment in motor control centers (MCCs) in conjunction with vertical busbars. Generally, all 3K. 5 switch disconnectors can be secured on the shaft with a padlock to prevent unauthorized reclosing. Identical accessories for 3K switch disconnectors and for 3KL and 3KM switch disconnectors with fuses simplify stock keeping. Please inquire about a special variant with reduced values that is particularly resistant to atmospheres high in sulfur, e. g. in the paper and cellulose processing industries. Siemens 2009 25

3KL, 3KM, 3NJ6 Switch Disconnectors with Fuses 3KL Switch Disconnectors with Fuses up to 800 General data Technical specifications Standards IEC 60947-1, IEC 60947-3, VDE 0660 Part 107 Type 3KL50 3KL52 1) 3KL53 1) 3KL55 1) 3KL57 1) 3KL61 1) 3KL62 1) Rated uninterrupted current I u 63 125 160 250 400 630 800 For fuse links acc.to DIN 43620, Size 00 and 00 and 00 and 1 and 2 1 and 2 3 and 2 3 and 2 (when SITOR semiconductor fuses are used, a reduction of rated current is necessary, see Catalog SITOR Configuration, Order No. E20001-700-P302) 000 000 000 Conventional free-air thermal current I 2) th 63 125 160 250 400 630 800 Rated insulation voltage U i V 690 1000 1000 1000 1000 1000 1000 Rated impulse voltage U imp kv 6 8 8 8 8 8 8 Rated operational voltage U e C 50 Hz/60 Hz V 690 DC V 440 (3 conducting paths series-connected) 220 (2 conducting paths series-connected) 3) Rated short-circuit making capacity with fuses 3) k 220 220 220 176 176 105 105 t50hz/60hz 690V C (peak Rated conditional short-circuit current with fuses 3) k 100 100 100 80 80 50 50 t50hz/60hz 690V C (rms Max. rated current I n of the fuses 80 160 160 400 400 630 800 Max. permissible power loss of the installed fuse LV HRC W 6 9 11.5 32 45 48 62 BS W 8 (2/3) 11.5 (4) 11.5 32 45 48 60.5 Permissible let-through current of the fuses k 8 17 17 30 5) 30 5) 50 50 Maximum permissible let-through I 2 t value k 2 s 55 223 223 1000 1000 5400 10500 Switching capacity (infeed from top or bottom) t 400 V C Breaking current I c (p.f. = 0.35) (rms 500 1000 1280 2000 3200 5100 6400 63 125 160 250 400 630 6) 800 6) Rated operational current I e at C-21, C-22, C-23 Motor switching capacity C-23 kw 30 65 80 132 200 335 400 t 500 V C Breaking current I c (p.f. = 0.35) (rms 500 1000 1280 2000 3200 5100 6400 63 125 160 250 400 630 6) 800 6) Rated operational current I e at C-21, C-22, C-23 Motor switching capacity C-23 kw 40 90 110 185 280 425 500 t 690 V C Breaking current I c (p.f. = 0.35) (rms 500 1000 1280 2000 3200 5100 6400 63 125 160 250 400 630 5) 800 5) Rated operational current I e at C-21, C-22, C-23 Motor switching capacity C-23 kw 50 110 150 220 375 560 700 t 440 V DC (3 conducting paths series-connected) 7) Breaking current I c (L/R = 15 ms) 250 500 640 1000 8) 1600 2520 9) 2520 9) Rated operational current I e at DC-23 63 125 160 250 10) 400 630 10) 630 10) Rated short-time current (1 s current) k 2.5 3.2 3.2 8 11 32 32 (rms Permissible load Depending on the ambient temperature for open-type installation in control panels (e. g. 8N1) in control cubicles or control racks at 35 C 63 125 160 250 400 630 800 40 C 63 125 155 250 390 630 780 45 C 63 125 150 250 380 610 760 50 C 63 125 145 250 370 590 740 55 C 63 125 140 240 360 570 720 Permissible ambient temperature C -25... +55 for operation 3), C -50... +80 when stored Mechanical endurance Operating 15000 15000 15000 12000 12000 3000 3000 cyc- les Required operating torque Nm 3 7.5 7.5 16 16 30 30 Degree of protection IP00/IP20 (from the operator side, with fuse and terminal covers) Power loss of the switch disconnector at I th W 8.5 22 36 33 86 140 225 (plus power loss of the fuses) Main conductor connections Busbar systems, max. dimensions (w x t) mm x mm 25 x 9 45 x 10 45 x 10 40 x 12 40 x 15 40 x 17 40 x 17 For footnotes see next page. 26 Siemens 2009

3KL, 3KM, 3NJ6 Switch Disconnectors with Fuses 3KL Switch Disconnectors with Fuses up to 800 General data Standards IEC 60947-1, IEC 60947-3, VDE 0660 Part 107 Type 3KL50 3KL52 1) 3KL53 1) 3KL55 1) 3KL57 1) 3KL61 1) 3KL62 1) Cable lug, max. conductor cross-section (stranded) mm 2 35 70 120 150 2 x 150 or 2 x 240 2 x 240 1 x 240 Tightening torque Nm 6... 7.5 7... 10 18... 22 35... 45 35... 45 56 56 Terminal screws M6 M6 M8 M10 M10 M12 M12 Protective conductor connections Flat bars mm x mm -- -- -- 20 x 2.5 20 x 2.5 -- -- Cable lug, max. conductor cross-section (stranded) mm 2 -- -- -- 70 120 -- -- uxiliary switch 1 NO + 1 NC (accessories) Max. number to be plugged 1 2 2 2 2 3 3 Rated operational current I e at C 50 Hz/60 Hz I e /C-12 10 I e /C-15 at U e = 220 V/230 V 6 I e /C-15 at U e = 380 V/400 V 4 I e /C-15 at U e = 500 V 2.5 I e /C-15 at U e = 690 V 1.2 Rated operational current I e at DC I e /DC-13 at U e = 24 V 10 I e /DC-13 at U e = 48 V 4 I e /DC-13 at U e = 110 V 1.2 I e /DC-13 at U e = 220 V 0.4 I e /DC-13 at U e = 440 V 0.2 Connection Solid mm 2 2 x (0.5... 1.5) Finely stranded with end sleeve mm 2 2 x (1... 2.5) Weight Complete version kg 1.450 2.560 2.560 5.400 5.700 -- -- Basic version kg 0.950 2.200 2.200 4.500 4.800 14.000 14.000 1) Technical specifications for approval on request. 2) Configuring note: max. permissible operating temperature for fuse blades 135 C, for connections 100 C. 3) 110 V (one conducting path). 4) With 3KL61 for operation -25 C... +35 C, at +55 C: I th = 570. 5) 3ND1 switchgear protection fuse. 6) C-23B. 7) 220 V DC (L1 and L3 series-connected) or 110 V DC (one conducting path) at DC-23. 8) t 440 V L/R = 4 ms, at 220 V L/R = 15 ms. 9) L/R = 2.5 ms. 10) t 440 V DC-22, at 220 V DC-23. Permissible mounting positions 10 180 180 180 NSE0_00182a Mounting position for 3KL switch disconnectors Note: For the 3KL switch disconnectors, complete kits for standard and EMERGENCY-STOP application are available for installation in the side and rear panels of control cabinets. Siemens 2009 27

3KL, 3KM, 3NJ6 Switch Disconnectors with Fuses 3KL Switch Disconnectors with Fuses up to 800 Surface mounting and installation Dimensional drawings 3KL50, 63, 3-pole, dimensional drawing for 4-pole version corresponds to dimensional drawing for 3KL52; without operating mechanism, with lyre-shaped contacts 3KL50, 63 with shaft and 8UC7 operating mechanism 5 - % # =! $ " # $ = # " $ $ % # " # $ # 1) To be kept free of conductive parts. Not necessary when using lyreshaped contacts or covers (accessories). a Shaft length NSE0_00291 Max. 380 300; unchanged shaft from 8UC71 R2 Min. 175 175-80 ; shortened shaft from 8UC71 175 < a < 380 a -80 6-0,1 Shaft (profile) Engaged length: min. 70 mm max. 150 mm 3KL50, 30, 63, 3-pole, dimensional drawing for 4-pole version corresponds to dimensional drawing for 3KL52; without operating mechanism, for BS fuses "! # " # # 3KL52, 125, 3KL53, 160 with shaft and 8UC7 operating mechanism 5 - & = & $ " # " # $ $ # #! #! ' # '! $ N! # # % # 5 - % $ = # " $ $ % # " # $ # = a Shaft length Max. 350 300; unchanged shaft from 8UC72 Min. 165 165-50 ; shortened shaft from 8UC72 165 < a < 350 a -50 NSE_00281 Shaft (profile) Engaged length: R2 min. 90 mm 8-0,1 max. 143 mm 3KL52, 125, 3KL53, 160, 3KL50, 63, 4-pole without operating mechanism, with lyre-shaped contacts n 15 85 55 63 c h NSE0_00277a 35 39 100 110 g 143 i l * 100 22,5 3KL52, 125, 3KL53, 160, 3KL50, 63, 4-pole without operating mechanism, for BS fuses 25 e 38 90 185 5 To be kept free of conductive parts. Not necessary when using lyre-shaped contacts or covers (accessories). Type c e g h n 3KL52 NH 15 37 42 91 106 3KL53 NH 20 39 39.5 105 125 3KL52 2/3 15 37 42 91 106 3KL53 4 20 39 39.5 105 125 4th pole 15 -- 48 91 106 149 Type c e g h n 3KL52 NH 15 37 42 91 106 3KL53 NH 20 39 39.5 105 125 3KL52 2/3 15 37 42 91 106 3KL53 4 20 39 39.5 105 125 4th pole 15 -- 48 91 106 IP20 cover for 3KL Type For B C D 3KX3507-0C02 3KL50 210 90 50 130 3KX3527-0C02 3KL52 260 114 72.5 208 3KX3537-0C02 3KL53 260 114 72.5 208 3KX3557-0C02 3KL55 340 142 101 262 3KX3557-0C02 3KL57 340 142 101 262 28 Siemens 2009

3KL, 3KM, 3NJ6 Switch Disconnectors with Fuses 3KL Switch Disconnectors with Fuses up to 800 Surface mounting and installation 3KL55, 250, 3KL57, 400 without operating mechanism, with lyre-shaped contacts 26,5 107 86 25 65 11 a b c 207 41 16 135 160 130 11 20 7 7 17 100 240 NSE0_00282a 3 195,5 (size 1) 203,5 (size 2) 209 Type a b c 3KM55 40 4 M 10 x 30 3KM57 38 6 M 10 x 36 4th pole 80 4 M 10 x 30 NSE0_00283 10-0,1 R2 Shaft (profile) Engaged length: min. 170 mm max. 205 mm 3KL55, 250, 3KL57, 400 with shaft and 8UC7 operating mechanism 5 - & " = " $! $ # " & & # # & & = a Shaft length Max. 335 300; unchanged shaft from 8UC73 Min. 230 230-35 ; shortened shaft from 8UC73 230 < a < 335 a -35 3KL61, 630, 3KL62, 800 without operating mechanism, with lyre-shaped contacts, with partitions 9 20,5 345 315 NSE00286 1 4th pole for 3KL61 ' # 180 26 78 12 208 270 230 280 5 - ' # = # # ' " 40 95,5 87 87 Total installation depth with handle: 239 + 74,5 + 66,5 = 370 29 M 12 234 239 240 74,5 66,5! ' ' " # 1 Profile 12 x 12. Shaft length 110. Shaft can be turned by 45 Schematics Internal circuit diagram for 3KL (for 3KL50 and 3KL51, only one auxiliary switch possible, not included in scope of supply; 4th pole is possible as main contact) (auxiliary switch not included in scope of supply) Use for DC voltage at DC-23 440 V Siemens 2009 29

3KL, 3KM, 3NJ6 Switch Disconnectors with Fuses 3KM Switch Disconnectors with Fuses and Isolating Plug Connector up to 400 General data Overview 7 2 NSE0_01557a 4 1 5 6 7 9 3 7 3KL or 3KM basic device Plug-in contact strip for 3KM Fuses, optionally BS-88 or LV HRC fuses Terminal cover, IP20 (vertical to operator side) Coupling driver with extension shaft Standard products from the Siemens 3SB1 range are used as auxiliary switches. Single-pole terminal cover from 63 to 630, IP20 (vertical to operator side) 8 Optional 8UC9 knob for fixed mounting in standard version (black) or EMERGENCY-STOP version (red), or 9 8UC7 door-coupling rotary operating mechanism in standard version (ti-grey) or EMERGENCY-STOP version (red/yellow) 3 ll components from the switch to the actuator are provided with non-interchangeability features. Design ll switch disconnectors feature double contact interruption and an isolating distance. s a result, the fuses are de-energized when the switch disconnectors are in the disconnected position. The 3KM switch disconnectors with fuses also feature an isolating plug connector. This facilitates mounting and contact establishment in motor control centers (MCCs) in conjunction with vertical busbars. Generally, all 3K.5 switch disconnectors can be secured on the shaft with a padlock to prevent unauthorized reclosing. Identical accessories for 3K switch disconnectors and for 3KL and 3KM switch disconnectors with fuses simplify stock keeping. Please inquire about a special variant with reduced values that is particularly resistant to atmospheres high in sulfur, e. g. in the paper and cellulose processing industries. 30 Siemens 2009

3KL, 3KM, 3NJ6 Switch Disconnectors with Fuses 3KM Switch Disconnectors with Fuses and Isolating Plug Connector up to 400 Technical specifications Standards IEC 60947-1, IEC 60947-3, VDE 0660 Part 107 General data Type 3KM50 3KM52 3KM53 3KM55 3KM57 Rated uninterrupted current I u 63 125 160 250 400 For fuse links acc. to DIN 43620, Size 00 and 000 00 and 000 00 and 000 1 and 2 1 and 2 (when SITOR semiconductor fuse links are used, a reduction of rated current is necessary, see Catalog SITOR Configuration, Order No. E20001-700-P302) Conventional free-air thermal current I 1) th 63 125 160 250 400 Rated insulation voltage U i V 690 1000 1000 1000 1000 Rated impulse voltage U imp kv 6 8 8 8 8 Rated operational voltage U e C 50 Hz/60 Hz V 690 DC V 440 (3 conducting paths series-connected) V 220 (2 conducting paths series-connected) 2) Rated short-circuit making capacity with fuses k 220 220 220 176 176 t 50 Hz/60 Hz 690 V C (peak Rated conditional short-circuit current with fuses k 100 100 100 80 80 t 50 Hz/60 Hz 690 V C (rms Max. rated current I n of the fuses 80 160 160 400 400 Max. permissible power loss of the installed fuse LV HRC W 6 9 11.5 32 45 BS W 8 (2/3) 11.5 (4) 11.5 32 45 Permissible let-through current of the fuses k 8 17 17 30 4) 30 4) Maximum permissible let-through I 2 t value k 2 s 55 223 223 1000 1000 Switching capacity (infeed from top or bottom) t 400 V C Breaking current I c (p.f. = 0.35) (rms 500 1000 1280 2000 3200 63 125 160 250 400 Rated operational current I e at C-21, C-22, C-23 Motor switching capacity C-23 kw 30 65 80 132 200 t 500 V C Breaking current I c (p.f. = 0.35) (rms 500 1000 1280 2000 3200 63 125 160 250 400 Rated operational current I e at C-21, C-22, C-23 Motor switching capacity C-23 kw 40 90 110 185 280 t 690 V C Breaking current I c (p.f. = 0.35) (rms 500 1000 1280 2000 3200 63 125 160 250 400 Rated operational current I e at C-21, C-22, C-23 Motor switching capacity C-23 kw 50 110 150 220 375 t 440 V DC (3 conducting paths series-connected) 4) Breaking current I c (L/R = 15 ms) 250 500 640 1000 5) 1600 Rated operational current I e at DC-23 63 125 160 250 6) 400 Rated short-time current (1 s current) k 2.5 3.2 3.2 8 11 (rms Permissible load Depending on the ambient temperature for open-type installation in control panels (e. g. 8N1) in control cubicles or control racks at 35 C 63 125 160 250 400 40 C 63 125 155 250 390 45 C 63 125 150 250 380 50 C 63 125 145 250 370 55 C 63 125 140 240 360 Permissible ambient temperature C -25... +55 for operation 3) C -50... +80 when stored Mechanical endurance Operating 15000 15000 15000 12000 12000 cyc- les Required operating torque Nm 3 7.5 7.5 16 16 Degree of protection IP00/IP20 (from the operator side, with fuse and terminal covers) Power loss of the switch disconnector at I th W 8.5 22 36 33 86 (plus power loss of the fuses) Main conductor connections Busbars, max. dimensions (w t) mm mm 25 9 45 10 45 10 40 12 40 15 Cable lug, max. conductor cross-section (stranded) mm 2 35 70 120 150 2 150 or 1 240 Siemens 2009 31

3KL, 3KM, 3NJ6 Switch Disconnectors with Fuses 3KM Switch Disconnectors with Fuses and Isolating Plug Connector up to 400 General data Standards IEC 60947-1, IEC 60947-3, VDE 0660 Part 107 Type 3KM50 3KM52 3KM53 3KM55 3KM57 For footnotes see next page. Busbars, max. dimensions (w t) mm mm 25 9 45 10 45 10 40 12 40 15 Tightening torque Nm 6... 7.5 7... 10 18... 22 35... 45 35... 45 Terminal screws M6 M6 M8 M10 M10 Protective conductor connections Flat bars mm mm -- -- -- 20 2.5 20 2.5 Cable lug, max. conductor cross-section (stranded) mm 2 -- -- -- 70 120 uxiliary switch 1 NO + 1 NC (accessories) Max. number to be plugged 1 2 2 2 2 Rated operational current I e at C 50 Hz/60 Hz I e /C-12 10 I e /C-15 at U e = 220 V/230 V 6 I e /C-15 at U e = 380 V/400 V 4 I e /C-15 at U e = 500 V 2.5 I e /C-15 at U e = 690 V 1.2 Rated operational current I e at DC I e /DC-13 at U e = 24 V 10 I e /DC-13 at U e = 48 V 4 I e /DC-13 at U e = 110 V 1.2 I e /DC-13 at U e = 220 V 0.4 I e /DC-13 at U e = 440 V 0.2 Connection Solid mm 2 2 (0.5... 1.5) Finely stranded with end sleeve mm 2 2 (1... 2.5) Weight Complete version kg 1.936 2.960 2.960 7.160 7.450 Basic version kg 1.820 2.600 2.600 6.147 6.443 1) Configuring note: max. permissible operating temperature for fuse blades 135 C, for connections 100 C. 2) 110 V (one conducting path). 3) 3ND1 switchgear protection fuse. 4) 220 V DC (L1 and L3 series-connected) or 110 V DC (one conducting path) at DC-23. 5) t 440 V L/R = 4ms, at 220V L/R = 15 ms. 6) t 440 V DC-22, at 220 V DC-23. Permissible mounting positions 10 180 180 180 NSE0_00182a Mounting position for 3KM switch disconnectors 32 Siemens 2009

3KL, 3KM, 3NJ6 Switch Disconnectors with Fuses 3KM Switch Disconnectors with Fuses and Isolating Plug Connector up to 400 For snapping onto busbars Dimensional drawings 3KM50, 63 with shaft and 8UC7 operating mechanism 5 - & % = $! $ " # 3KM50, 63 without operating mechanism, with lyre-shaped contacts 120 43,5 1) 22,5 100 = # " a Shaft length Max. 380 300; unchanged shaft from 8UC71 Min. 175 175-80 ; shortened shaft from 8UC71 175 < a < 380 a -80 $ $ % # " # $ # 71 150 42 25 25 90 5-6,4 60 172 60 206 25 40 9 60 89 NSE00288a 23 2 134 135 M 6x20 7,5 1) To be kept free of conductive parts. Not necessary when using lyre-shaped contacts or covers (accessories). 3KM50, 63 without operating mechanism, for BS fuses Drilling pattern and connector cutout NSE00290 5,5 25 25 5,5 90 175 5,5 6 40 31 Shaft middle NSE0_00291 R2 6-0,1 Shaft (profile) Engaged length: min. 70 mm max. 150 mm 1) To be kept free of conductive parts. Not necessary when using lyre-shaped contacts (included in the scope of supply) or covers (accessory). 3KM52, 125 3KM53, 160 with shaft and 8UC7 operating mechanism NSE0_00292a 8 60 42-50 3KM52, 125 3KM53, 160 without operating mechanism, with lyre-shaped contacts (for further dimensions see 3KL52 and 3KL53) # a 1,5...4 66 75 4,5 65 " # "!? " ' C E a Shaft length Max. 350 300; unchanged shaft from 8UC72 Min. 165 165-50 ; shortened shaft from 8UC72 165 < a < 350 a -50 % " # $ $ % & # # $ " # % 5 - '! > Type c e g i l 3KM52 15 37 42 3 Ø 6.6 3KM53 20 39 39.5 3.5 Ø 9 1) To be kept free of conductive parts. Not necessary when using lyre-shaped contacts or covers (accessories). Siemens 2009 33

C E 3KL, 3KM, 3NJ6 Switch Disconnectors with Fuses 3KM Switch Disconnectors with Fuses and Isolating Plug Connector up to 400 For snapping onto busbars 3KM52, 125 3KM53, 160 without operating mechanism, for BS fuses ' $ Drilling pattern and cut-out in the mounting plate for mounting 3KM52 175 " ' " "! 31 % # $ " # $ $ % & #? # % 5 - ' " > 6 " & Cutout in the mounting plate 35 25 25 60 90 5,5 Shaft middle NSE0_00295a Type c e g i l 3KM52 15 37 42 3 Ø 6.6 3KM53 20 39 39.5 3.5 Ø 9 NSE0_00296a 8-0,1 R2 Shaft (profile) Engaged length: min. 90 mm max. 143 mm 3KM55, 250 3KM57, 400 with shaft and 8UC7 operating mechanism 5 - ' % = " $! $ # 3KM55, 250 3KM57, 400 without shaft, without operating mechanism, with lyre-shaped contacts (further dimensions see 3KL55) 7 240 160 & & # " # # = a Shaft length Max. 335 300; unchanged shaft from 8UC73 Min. 230 230-35 ; shortened shaft from 8UC73 230 < a < 335 a -35 & & 207 70 41 25 5-6,4 209 NSE0_00298b z y x 195,5 (size 1) 203,5 (size 2) 60 60 172 25 3KX3 508-0 busbar support for bars 30 mm 5 mm & # $ $ #! 5 - ' ' $ " Type x y z 3KM55 4 40 M 10 x 30 3KM57 6 38 M 10 x 36 Drilling pattern and cut-out in the mounting plate for mounting 3KM55 and 3KM57 31 175 Cutout in the mounting plate $ # NSE0_00283 10-0,1 R2 Shaft (profile) Engaged length: min. 170 mm max. 205 mm 31,5 75 17,5 25 41 100 7 NSE00301a Shaft middle 34 Siemens 2009

3KL, 3KM, 3NJ6 Switch Disconnectors with Fuses 3KM Switch Disconnectors with Fuses and Isolating Plug Connector up to 400 For snapping onto busbars Cut-outs for 3K. 50, 3K51 with 3KX3 516-... rear manual operating mechanism " & # # # $ 5 -! Cut-outs for 3K. 52, 3K. 53 with 3KX3 526-.../3KX3 536-... rear manual operating mechanism Cut-outs for 3K. 55, 3K. 57, 3K. 58 with 3KX3 556-... rear manual operating mechanism # & # # $ & 5 -! " = # # # & " & " & # & # $ $ 5 -!! = Schematics Internal circuit diagram for 3KM (for 3KM50 and 3KM51, only one auxiliary switch possible) Siemens 2009 35

3KL, 3KM, 3NJ6 Switch Disconnectors with Fuses 8UC Door-Coupling Rotary Operating Mechanisms For 3K switch disconnectors Overview NSE0_00350a max.5 -max.5 max.5 +max.5 max.5 max.5 Permissible radial eccentricity and axial tolerance compensation Switch position In order to ensure compliance with locking and interlocking conditions, the controls and operating mechanisms must be installed such that, with two-position switches the "0" position lies at 9 o'clock and the "I" position at 12 o'clock. 4 standard sizes of operating mechanisms are available: Size Rated torque 1) Shaft profile Masking plate Nm mm x mm mm x mm 1 4 6 x 6 75 x 75 2 9 8 x 8 75 x 75 3 25 10 x 10 or 100 x 100 12 x 12 4 40/55 2) 12 x 12 100 x 100 1) Operating mechanisms tested with triple torque (VDE 0660 Part 107). They are therefore qualified for use in all controls, especially for disconnectors. 2) Operation with two hands. Design Operating mechanisms consist of a masking plate with handle including seal and fixing screws for door installation and of a shaft coupling, extension shaft (300 mm) and coupling driver to be mounted onto the switch shaft. Operating mechanisms for 3K/3KL/3KM switch disconnectors do not have a shaft coupling since the extension shaft is fitted directly into the switch. Extension shafts with a length of 600 mm are available. Masking plates are light-gray with black inscription, handles are ti-grey. For EMERGENCY-STOP switches, a yellow indicator plate with black inscription is mounted; the handles are red. The retractable locking device (light green basic) for padlocks is integrated in the handle. The door interlock on the rotary operating mechanisms is suitable for padlocks with shackle diameters of 4.5 mm to 8.5 mm (locks according to DIN 7465). Up to three locks with shackle diameter of 8.5 mm or up to five locks with shackle diameter of 6 mm can be fitted. Mounting instructions are included in the scope of supply. Operating instructions containing hints on activation or modification of interlocking conditions are available by quoting Order No. 8ZX1012-0UC60-11 or can be downloaded. The Internet address is: http://www.siemens.com/lowvoltage 8UC7 door-coupling rotary operating mechanisms are capable of taking up a radial eccentricity of max. 5 mm between the actuating shaft of the switching device and the operating mechanism. Supporting the extension shaft is recommended with greater tolerances. ±5 mm can be compensated in axial direction. The distance between the door hinge and the center of rotary operating mechanism must not be less than 100 mm. 0 2 1 90 NSE0_00352a 1 12 o'clock position 2 9 o'clock position Positions for two-position switches with 90 operating angle Non-interchangeability In order to ensure that, when installing switches and door-coupling operating mechanisms, all components - the actuating shaft, shaft coupling, extension shaft, coupling driver and doorcoupling operating mechanism - are assembled in the correct position with respect to one another, all the above-mentioned parts are provided with non-interchangeability features (groove and lug). For controls whose non-interchangeability groove is not at 3 o'clock in the "0" position or switches that can be installed at an angle of 90 to the left or right, the non-interchangeability groove can be repositioned. When the switch and the door coupling are fitted, the rivet in the shaft coupling or coupling driver is moved accordingly. ll doorcoupling rotary operating mechanisms listed in this catalog are supplied with the "0" position of the mechanism at 9 o'clock and the "I" position at 12 o'clock. This refers to controls to be installed in the normal mounting position. In operation and when performing maintenance, these non-interchangeability features preclude the risk of accidents caused by incorrect handling or incorrect switching operations. NSE0_00351a Non-interchangeability features (see arrows) of rotary operating mechanisms 36 Siemens 2009

3KL, 3KM, 3NJ6 Switch Disconnectors with Fuses 8UC Door-Coupling Rotary Operating Mechanisms For 3K switch disconnectors 1 2 1 2 Handle ctuating shaft of the control Correlation between handle of rotary operating mechanism and actuating shaft Stops To prevent damage to smaller switches, an excessive manual operating torque can be absorbed by stops fitted on the inside of sizes 1 and 2 rotary operating mechanisms. These stops are supplied loose with the operating mechanisms and can be fitted as required after consulting the operating instructions. Stops are fitted at the factory to size 1 and 2 operating mechanisms with a 90 operating angle (exception: 3V. circuit breakers). Pull-out strength The pull-out strength of interlocked operating mechanisms, e. g. pulling off the shaft or destruction of the operating mechanism, amounts to 800 N when the pulling force acts directly onto the operating mechanism in direction of shaft. NSE0_00354 Function The basic (standard) versions of the rotary operating mechanisms comply with the following interlocking conditions: Operating mechanism and switch in "0" (OFF) position: The control cabinet door can be opened, the operating mechanism is uncoupled and the handle of the rotary operating mechanism engages. If padlocks are fitted with the control cabinet door closed and the actuator is set to "0", the operating mechanism (and switch) cannot be actuated and the door cannot be opened. Operating mechanism and switch in "I" (ON) position: The control cabinet door cannot be opened in this position. The interlocking mechanism can, however, be overridden by trained personnel (pressing of a concealed latch with a screwdriver or the like), thus making it possible to open the control cabinet door in the "I" position of the control for performing checks. The handle engages in the "I" setting with the door open. In the "I" position it is not possible to fit padlocks to lock the operating mechanisms. Other interlocking conditions If no door interlock is required, the user can remove the door interlocking plate of the rotary operating mechanism after consulting the operating instructions. If provision is to be made for fitting padlocks to the rotary operating mechanism in the "I" position as well, the user can easily achieve this after consulting the operating instructions by knocking out a lug. Such a measure must not, however, be implemented with EMERGENCY-STOP rotary operating mechanisms. If padlocks are fitted in the "I" position of the rotary operating mechanism, the mechanism cannot be actuated, the control cabinet door cannot be opened and the operating mechanism cannot be overridden in order to open the door. If necessary the rotary operating mechanisms can also be locked in the 90, 180 position etc. as well as in the "0" position. The measures previously listed in item 2 under "Other Interlocking Conditions" must be carried out by the user. In the case of rotary operating mechanisms for switches without "0" position, such as stepping switches without "0" position, the door interlocking plate is removed. Siemens 2009 37

3KL, 3KM, 3NJ6 Switch Disconnectors with Fuses 8UC Door-Coupling Rotary Operating Mechanisms For 3K switch disconnectors Dimensional drawings 8UC71 and 8UC72 door-coupling rotary operating mechanisms, sizes 1 and 2 1 2 3 4 5 6 7 8 9 C 22 1 4 3 P4x11,5 300 1) 5,5 1 29 1 1,5... 4 28 BD Section - B NSE0_00490c Section C - D! " # $ ' With extension shaft Without extension shaft Door cut-out with mounting holes ' "! 2 " N # # # # " " # " # $ # 5 - " '? $ Selector switch % Coupling driver & Masking plate ( Seal ) Door * Fixing screw, 4 units + Extension shaft, Shaft coupling - ctuating shaft of the control 8UC73 to 8UC74 door-coupling rotary operating mechanisms, sizes 3 and 4 1 2 3 4 5 6 7 8 9 22,5 7 1 45,5 1 1,5... 4 1 1) 300 C 3 1 40 P5x13,5 B D Section - B NSE0_00492c Section C - D! " # $ ' % " # # #! 2 # N! # # " # # $! $ # & & 5 - " '!? $ Handle or twin handle % Coupling driver & Masking plate ( Seal ) Door * Fixing screw, 4 units + Extension shaft, Shaft coupling - ctuating shaft of the control With extension shaft Without extension shaft Door cut-out with mounting holes 1) Length of extension shaft can be cut to fit mounting depth. Extension shaft also available in 600 mm length. 38 Siemens 2009

3KL, 3KM, 3NJ6 Switch Disconnectors with Fuses 8UC Door-Coupling Rotary Operating Mechanisms Individual parts Dimensional drawings 8UC60 coupling driver 5 - ' " # = = = > = Coupling drivers With tolerance compensation Without tolerance compensation a b Shaft length +5 ±5 x +1.5 ±2.5 x+23.5 8UC92 53 shaft coupling = 8UC71, size 1 NSE0_00495a 75 13 22 1) 36 57 8 8UC72, size 2 NSE0_00495a 75 8UC73, size 3 100 13 22 1) 62 57 8 15 22 1) NSE0_00496b 140 79 8 8UC74, size 4 100 15 22 1) NSE0_00499b 200 79 8 Handles with masking plate, sizes 1 to 4 1) Padlock feature of handle pulled out. Siemens 2009 39

3KL, 3KM, 3NJ6 Switch Disconnectors with Fuses 8UC Door-Coupling Rotary Operating Mechanisms Operating mechanisms for fixed mounting Dimensional drawings 8UC93 54, 3KX3 516-1 operating mechanisms for fixed mounting Size 1 8UC93 60 to 8UC93 63, 3KX3 536-1 operating mechanisms for fixed mounting Size 2 8UC93 65 to 8UC93 75, 3KX3 176-1E operating mechanisms for fixed mounting Sizes 3 and 4 8UC93 81 to 8UC93 82, 3KX3 616-1 operating mechanisms for fixed mounting Size 5 45 NSE0_00488 25,5 5 - " & ' = # " # # a Size Shape a 3 140 4 200 65 Size Shape a 5 280 = $ # 40 Siemens 2009

3NP, 3NJ4, 3NJ5 Fuse Switch Disconnectors 3NP Fuse Switch Disconnectors up to 630 General data Design Function The SENTRON 3NP4 and 3NP5 fuse switch disconnectors comprise a base and a removable fuse carrier with view and measu- Fuse monitoring by SIRIUS motor starter protector ring window. For fuse monitoring, a SIRIUS motor starter protector is factoryfitted and hard-wired to the fuse carrier of the SENTRON 3NP4 The base contains integral lyre-shaped contacts, arcing chambers and terminal fittings. The fuse links/isolating links are con- and 3NP5 fuse switch disconnectors. tained in the fuse carrier. If the fuse carrier is closed, the three conducting paths of the SI- RIUS motor starter protector are switched in parallel to the fuse The fuse links can be replaced without tools. links to be monitored. If the fuse carrier is open, all main current The three conducting paths in the base and the fuse links in the paths of the motor starter protector are off circuit. fuse carrier are separated by partitions that overlap when opening and closing the device. ough not to impair the protective function of the monitored fuse The internal resistance of the motor starter protector is high en- This type of intrinsic protection is called "complete compartmentalization" and effectively prevents inter-phase arcing. Failure of a fuse will trigger the motor starter protector. The auxi- links. SENTRON 3NP5 fuse switch disconnectors are also equipped liary switch of the motor starter protector can be used for indication purposes or to disconnect the main circuit, e. g. through a with locating springs, which are fitted to the side of the base. These enable the "high speed closing" of devices, regardless of contactor. the actuating speed of the operator. The signal cable for the SENTRON 3NP4 fuse switch disconnector size NH 00 needs to be ordered separately. For sizes NH 1 to LV HRC fuses of sizes NH 000 to NH 3 according to IEC 60269-2 and DIN 43620 are used in the SENTRON 3NP4 NH 3 the connection is via flat connectors. and 3NP5 fuse switch disconnectors. SITOR semiconductor Delivery of the SENTRON 3NP5 fuse switch disconnectors includes the signal cable, complete with connector. fuses can also be used. For more detailed information, please refer to the operating instructions for the SENTRON 3NP4 and 3NP5 fuse switch ring in branch circuits by motor starter protectors where a fault SIRIUS motor starter protectors cannot be used for fuse monito- disconnectors. may result in > 220 V DC feedback. uxiliary switches In the case of parallel cables and meshed systems, only a voltage difference of > 24 V at the switch will trigger the motor starter protector. The SENTRON 3NP4 and 3NP5 fuse switch disconnectors can also be retrofitted with auxiliary switches for indicating the switch position of the fuse carrier. Electronic fuse monitors One switching block (1 CO) can be mounted on size For electronic fuse monitoring, the EF monitor is factory-fitted NH 000 of the SENTRON 3NP4 fuse switch disconnector and and hard-wired to the fuse carrier of SENTRON 3NP5 fuse switch two switching blocks (1 CO) can be mounted on sizes disconnectors. NH 00 to NH 3. The EF monitor works independently of any loads. Failure of a SENTRON 3NP5 fuse switch disconnectors can also be delivered with a 2-pole auxiliary switch (1 NO + 1 NC) if required. ary switches (2 NO + 1 NC) by means of a centralized fault indi- fuse can be relayed to a control room through integrated auxili- The version with fuse monitoring is fitted with this auxiliary switch cation or used to isolate the load through e. g. a contactor as standard. ctuation of the auxiliary switch depends on the EF monitor. Version "" stands for "open-circuit principle", version "R" for closedcircuit principle" (see schematic circuit diagram on page 53). If a fuse is tripped, a green LED signal flashes (general fault) and the location of the failed fuse is indicated by a red LED. Using more than one device facilitates identification of the affected branch circuit. The EF monitor is automatically reset to the standby position once the faulty fuses are replaced. This state is indicated visually by the status display (green LED). The EF monitor is also suitable for operation in industrial networks badly afflicted by harmonics. Siemens 2009 41

3NP, 3NJ4, 3NJ5 Fuse Switch Disconnectors 3NP Fuse Switch Disconnectors up to 630 General data Technical specifications Standards IEC/EN 60947-1, IEC/EN 60947-3 Type 3NP40 1 3NP40 7 3NP42 7 3NP43 7 3NP44 7 Rated uninterrupted current I u 160 1) 160 250 400 630 For fuse links acc. to DIN 43620 Size 00C/000 00 1 and 0 2 and 1 3 and 2 Conventional free-air thermal current I th 160 1) 160 250 400 630 Rated operational voltage U e C 50 Hz/60 Hz V 690 690 DC V 220 440 (3 conducting paths series-connected) (2 conducting paths series-connected) Rated insulation voltage U i V 690 690 800 3) 800 3) 800 3) Rated impulse withstand voltage U imp kv 6 6 6 6 6 Rated conditional short-circuit current with fuses (for fast switch-on) With fuse links Rated current Size/ 000/100 (35) 00/160 1/250 2/400 3/630 t 400 V C (690 V) k 50 (50) 50 50 50 50 (rms Maximum permissible let-through I 2 t value k 2 s 56 (7.8) 158 551 1515 4340 Permissible let-through current of the fuse k 11 (5) 15 25 35 55 (peak Short-circuit strength with fuses (with closed switch) With fuse links Rated current Size/ 000/100 00/160 1/250 2/400 3/630 t 690 V k 100 50 50 50 50 (rms Permissible let-through current of the fuse k 15 15 25 35 55 (peak Rated making and breaking capacity (infeed from top or bottom) t 400 V C, with fuse links or isolating links Size 000 00 1 2 3 Rated breaking current I c (p.f. = 0.35) (rms 800 (p.f. = 0.45) 800 2000 3200 5040 Rated operational current I e for C-21B, C-22B, C-23B 1) 125/160 only with 3NY1 236 feeder terminals and with 3NY1 822 (125 ) and 3NY1 824 (160 ) 21 mm wide fuse links; see ccessories. 2) When switching without load (C-20 B, DC-20 B), direct voltages up to 690 V DC can be applied. 3) For safety monitoring max. 690 V. 4) For degree of pollution 2, the switch disconnectors can be used up to 1000 V C-20 B, DC-20 B (no-load switching). 5) Conducting paths in series: 3 for 3NP40; 2 for 3NP42, 3NP43 and 3NP44. 160 100 t 500 V C, with fuse links or isolating links Size 000 00 1 2 3 Rated breaking current I c (p.f. = 0.35) (rms 320 (p.f. = 0.45) 320 750 1200 1890 Rated operational current I e for C-21B, C-22B, C-23B 160 100 40 t 690 V C, with fuse links or isolating links Size 000 00 1 2 3 Rated breaking current I c (p.f. = 0.35) 200/240 200/240 375 600 945 (rms (p.f. = 0.45/0.95) (p.f. = 0.45/0.95) Rated operational current I e for C-21B, C-22B, C-23B t 220 V/240 V DC, with fuse links 2)4)5) or isolating links Rated operational current I e at 220 V DC-23B/DC-21B 440 V DC-21B 160 50 25 160 100 160 100 40 160 50 25 250 250 250 250 -- 250 -- -- 400 400 400 400 -- 400 -- -- Size 000 00 1 2 3 80/160 -- 80/160 -- -- 250 -- 400 630 630 630 630 -- 630 -- -- -- 630 42 Siemens 2009

3NP, 3NJ4, 3NJ5 Fuse Switch Disconnectors 3NP Fuse Switch Disconnectors up to 630 General data Standards IEC/EN 60439-1, IEC/EN 60947-3 Type 3NP40 1 3NP40 7 3NP42 7 3NP43 7 3NP44 7 Capacitor switching capacity t 400 V C Capacitor rating kvar 50 50 -- -- -- Rated current I n 72 72 -- -- -- t 525 V C Capacitor rating kvar 50 50 -- -- -- Rated current I n 55 55 -- -- -- Permissible ambient temperature C -25... +55 1) for operation, -50... +80 when stored Mechanical endurance Operating 2000 2000 1600 1000 1000 cyc- les Degree of protection (operator side) Without molded-plastic masking frame/cable lug cover IP00 (3NP40 with box terminal and properly connected conductors: IP20) With molded-plastic masking frame/cable lug cover IP30 (switch closed), IP20 (switch open) Power loss of the switch disconnector at I th (plus power loss of fuse links) Without busbar adapter W 4.5 (at 100 ) 10 15 30 47 With busbar adapter W 8.5 (at 100 ) 20 47 83 127 Main circuit connection Flat connector for cable lug according to DIN 46234, max. conductor cross-section (stranded) Box terminal/terminal (finely stranded with end sleeve) 1) Only with isolating links; otherwise, please observe specifications of fuse manufacturer. mm 2 -- Up to 2 70 (M8) Up to 150 (M10) Up to 240 (M10) Up to 2 240 (M12) mm 2 1.5... 50 (35) 2.5... 70 (50) 70... 150 120... 240 150... 300 Busbar (width thickness) mm -- 22 5 22... 30 5... 10 Louvered Cu strips, unperforated in terminals (width x thickness) Tightening torques for terminal screws 22... 30 5... 10 25... 40 5... 10 mm 8 8 Up to 9 8 Up to 16 8 Up to 20 10 Up to 24 10 For flat connector Nm -- 10... 12 30... 35 30... 35 35... 40 With SIGUT box terminal/terminal Nm 3... 3.5 8... 10 6 8 8 uxiliary switch 1 CO (accessories) 3NY3 035 C 50 Hz/60 Hz up to 230 V Rated operational current I e at C-14 0.25 (I th = 5 ), at 24 V DC: I e = 0.45 ; flat terminations acc. to DIN 46244: 2.8 0.5 3NY3 030 C 50 Hz/60 Hz up to 230 V Rated operational current I e at C-13 0.1 (I th = 0.1 ); plug-in sleeve acc. to DIN 46245: 2.8... 1 Permissible mounting positions Vertical or horizontal installation (no reduction of specified switching capacity) Siemens 2009 43

3NP, 3NJ4, 3NJ5 Fuse Switch Disconnectors 3NP Fuse Switch Disconnectors up to 630 General data Standards IEC/EN 60947-1, IEC/EN 60947-3 Type 3NP50 3NP52 3NP53 3NP54 Rated uninterrupted current I u 160 250 400 630 For fuse links acc. to DIN 43620 Size 00 1 and 0 2 and 1 3 and 2 (when SITOR semiconductor fuse links are used, a reduction of rated current is necessary see Catalog "SITOR Configuration", Order No. E20001-700-P302) Conventional free-air thermal current I th 160 250 400 630 Rated operational voltage U e C 50 Hz/60 Hz V 690 DC V 440 (3 conducting paths series-connected), 220 (2 conducting paths series-connected and with fuse monitoring through 3RV) Rated insulation voltage U i V 690 1) 690 1) 690 1) 690 1) Rated impulse withstand voltage U imp kv 6 6 6 6 Rated conditional short-circuit current with fuses (for fast switch-on) With fuse links Rated current Size/ 00/160 1/250 2/400 3/630 t 500 V C k 50 50 50 50 (rms Permissible let-through current of the fuses k 15 25 40 50 (peak Short-circuit strength with fuses (with closed switch) With fuse links Rated current Size/ 00/160 1/250 2/400 3/630 t 500 V C k 100 100 50 50 (rms Maximum permissible let-through I 2 t value k 2 s 223 780 2150 5400 Permissible let-through current of the fuses k 23 32 40 60 (peak Rated short-circuit making capacity with isolating links 2) Size 00 1 2 3 t 500 V C k 6 17 17 17 (peak Rated making and breaking capacity 2) (infeed from top or bottom) 3) Size 00 1 0 2 1 3 2 t 400 V C, with fuse links Breaking current I c (p.f. = 0.35) Rated operational current I e at C-21B, C-22B, C-23B t 500 V C, with fuse links Breaking current I c (p.f. = 0.35) Rated operational current I e at C-21B, C-22B, C-23B t 690 V C, with fuse links Breaking current I c (p.f. = 0.35) Rated operational current I e for C-21B, C-22B, C-23B (rms 1600 2500 1600 4000 2500 5040 4000 160 250 160 400 250 630 400 (rms 1300 2500 1600 4000 2500 5040 4000 160 250 160 400 250 630 400 (rms 800 1280 1000 2520 1600 3200 2520 160 100 t 220 (440) V DC, with 2 (3) conducting paths series-connected and fuse links Breaking current I c (L/R = 15 ms) 640 1000 640 1600 1600 2520 1600 Rated operational current I e at DC-23B 160 250 160 250 250 630 400 250 160 160 125 400 315 250 200 630 400 400 315 1) When observing degree of pollution 2 (instead of 3) operation is also possible up to U i = 1000 V. 2) Rated making and breaking current according to IEC 60947-3 Rated making current I = 10 I e (C-23); 3 I e (C-22); 1.5 I e (C-21) Rated breaking current I e = 8 I e (C-23); 3 I e (C-22); 1.5 I e (C-21). 3) When using electronic fuse monitoring, infeed must be from the top. 44 Siemens 2009

3NP, 3NJ4, 3NJ5 Fuse Switch Disconnectors 3NP Fuse Switch Disconnectors up to 630 General data Standards IEC/EN 60947-1, IEC/EN 60947-3 Type 3NP50 3NP52 3NP53 3NP54 Switching capacity with isolating links 1) (infeed from top or bottom) 1) t 400 V C, with isolating links Size 00 1 2 3 Breaking current I c (p.f. = 0.35) (rms 1600 2500 2500 4000 Rated operational current I e for C-21B, C-22B, C-23B t 500 V C, with isolating links Breaking current I c (p.f. = 0.35) Rated operational current I e for C-21B, C-22B, C-23B t 690 V C, with isolating links Breaking current I c (p.f. = 0.35) Rated operational current I e for C-21B, C-22B, C-23B (rms (rms 160 160 250 250 400 315 630 500 1300 2500 2500 4000 160 160 250 250 400 315 630 500 800 1280 1600 2520 160 100 t 220 V DC, with isolating links Breaking current I c (L/R = 15 ms) 640 1000 1600 1600 Rated operational current I e at DC-23B 160 200 400 400 Switching capacity for horizontal installation Up to 690 V C-22B 250 160 No reduction in specified switching capacity (values for C-23B up to 690 V on request) 400 200 630 315 Permissible mounting positions 10 180 180 180 3NP5 NSE0_00182a 1) Insert silver-plated isolating links. Siemens 2009 45

3NP, 3NJ4, 3NJ5 Fuse Switch Disconnectors 3NP Fuse Switch Disconnectors up to 630 General data Standards IEC/EN 60947-1, IEC/EN 60947-3 Type 3NP50 3NP52 3NP53 3NP54 Capacitor switching capacity t 400 V C Capacitor rating kvar 80 90 150 250 Rated current I n 116 130 216 361 t 525 V C Capacitor rating kvar 100 125 200 300 Rated current I n 110 137 220 330 Permissible ambient temperature C -25... +55 for operation 1 ), -50... +80 when stored Mechanical endurance Operating 1600 cyc- les Degree of protection Without molded-plastic masking frame IP00 2) With molded-plastic masking frame and closed fuse carrier on the operator side IP30 With open fuse carrier IP10 Power loss of of the switch disconnector at I th (plus power loss of the fuse links) Without busbar adapter W 7.8 (16.3) 3) 7.5 15 39 Main conductor connections Cable lug, max. conductor cross-section (stranded) mm 2 2.5... 120 6... 150 6... 240 6... 2 240 Busbar mm 16... 22 22... 30 22... 30 22... 30 Clamp terminal mm 2 2.5... 50 35... 120 -- -- Tightening torque With cable lug Nm 18... 22 25... 30 25... 30 25... 30 With busbar Nm 18... 22 25... 30 25... 30 25... 30 With clamp terminal Nm 9... 11 5... 6 -- -- Terminal screws With cable lug M8 M10 M10 M10 With busbar M8 M10 M10 M10 With clamp terminal M8 2 M6 -- -- Protective conductor connections Cable lug acc. to DIN 46234 mm 2 -- 2.5... 70 6... 2 70 6... 2 120 Busbar mm -- 25 25 30 Terminal screws -- M8 M10 M10 uxiliary switch 1 NO + 1 NC (accessories) (the same voltage potential must be applied to both NO and NC contact) t C 50 Hz/60 Hz up to 400 V, 16/6 rated operational current I e at C-12/C-15 Flat connector (DIN 46244) 6.3... 0.8 Permissible mounting positions Vertical or horizontal (partially reduced switching capacity with horizontal mounting) Fuse monitoring with 3RV motor starter protectors See Motor Starter Protectors Electronic fuse monitoring Rated voltage C 50 Hz/60 Hz V 400-15 %... 500 V + 10 %, self-powered (infeed from top) Max. inrush current 20 Uninterrupted current 5 Breaking current 5 Switching capacity V 1000 Short-circuit strength (1 ms) 100 Response time s < 1 Temperature range (operation) C -10... +75 Plug-in connectors/connections 6-pole Minimum required potential difference V >10 between upper and lower switch connections (e. g. for use in meshed systems) Signaling contact for electronic fuse monitoring 2 NO + 1 NC Rated operational current I e t 250 V, DC-13 0.27 t 240 V, C-15 1.5 Thermal free-air rated current I th 5 1) When using isolating links. If using fuse links, please observe specifications of fuse manufacturer. 2) For 3NP52 with terminal clamp connection, degree of protection IP10. 3) With busbar adapter. 46 Siemens 2009

# 3NP, 3NJ4, 3NJ5 Fuse Switch Disconnectors 3NP Fuse Switch Disconnectors up to 630 3NP4 for power distribution Dimensional drawings 3NP40 10 " & & ' $ " # " " # # & # "! $ # %! # " " # # # # ) K N E E = H O I M E J? D % % # % " 5 - ' $ & # Cutout for 3NP35 and 3NP40 10 3NP40 10 with 3NY1 995 quick retaining plate mounting rail center-to-center spacing: 125 mm 3NY1 995 quick retaining plate for 3NP40 10 and 3NP40 70 Top holes with a 50 mm intermediate dimension must be used for installation in LPH distribution boards. 3NP40 10 with 3NY1 237 3-phase busbar for 2 fuse switch disconnectors 3NY1 265 covering cap for 3NY1 238 3-phase busbar 3NP40 10 with 3NY1 235 triple terminal 3NP40 10 with 3NY1 236 feeder terminal 3NP40 10 with 3NY1 251 molded-plastic masking frame 3NP40 15-1CJ01 with busbar adapter, flat, busbars of width 12 mm or 15 mm and thickness 5 mm or 10 mm, bottom connection 3NP40 15-1CK01 with busbar adapter, flat, busbars of width 12 mm or 15 mm and thickness 5 mm or 10 mm, bottom connection 3NP40 15-0CJ01 with busbar adapter, deep, busbars of width 12 mm or 15 mm and thickness 5 mm or 10 mm, bottom connection 3NP40 16-1CJ01 with busbar adapter, busbars of width 12, 15, 20 mm or 30 mm and thickness 5 mm or 10 mm, flat, T, I profiles and other renowned busbar systems, bottom connection 3NP40 16-1CK01 with busbar adapter, busbars of width 12, 15, 20, 25 mm or 30 mm and thickness 5 mm or 10 mm, flat, T, I profiles and other renowned busbar systems, top connection 19 100,5 89 69,5 11,5 168 60 60 NSE 00205a 25,5 25,5 10 14 72 201 Siemens 2009 47

3NP, 3NJ4, 3NJ5 Fuse Switch Disconnectors 3NP Fuse Switch Disconnectors up to 630 3NP4 for power distribution 3NP40 70 for surface mounting 108 50 70 83,5 170 161 101 45 36,5 3NP42 70, 3NP43 70, 3NP44 70 for surface mounting a f f b e c d NSE0_00207b 17 190 NSE00206a Drilling pattern for 3NP40 70 3NP40 75-0 with busbar adapter, deep, busbars of width 12 mm or 15 mm and thickness 5 mm or 10 mm Type a b c d e f 3NP42 70 184 243 66 45.5 215 57 3NP43 70 210 288 80 48 255 65 3NP44 70 256 300 94.5 48 267 81 3NY73 22 quick retaining plate 85 M 6 122,5 NSE0052 81,7 97,5 Drilling pattern for 3NP43 Drilling pattern for 3NP42 70 Drilling pattern for 3NP44 3NP40 75-1 with busbar adapter, flat, busbars of width 12 mm or 15 mm and thickness 5 mm or 10 mm $ Bottom edge disconnector-base % Center disconnector-base For plastic frames Cutouts 2) for 3NP40 70 Cut-outs 2) for 3NP42 70 50 5,8 118 110 NSE00523 195 25 11 116 114 130 50 157 274,4 For metal frames Cutouts for 3NP4 Type Cover betw. assembly kit Panel cut-out min. Molded-plastic masking frame behind panel Type B H B H h 1) 3NP40 1 3NY1 251 130 215 100 180 100 3NP40 7 3NY7 200, 130 215 118 195 110 3NY7 201 3NP42 7 3NY7 220 220 375 210 275 157 3NP43 7 3NY7 230 245 375 235 315 174 3NP44 7 3NY7 240 290 375 280 325 178 Molded-plastic masking frame in front of panel Type B H B H h 1) 3NP40 1 3NY1 251 130 215 100 155 87 3NP40 7 3NY7 200, 130 215 118 195 110 3NY7 201 3NP42 7 3NY7 220 220 375 198 275 157 3NP43 7 3NY7 230 245 375 224 315 174 3NP44 7 3NY7 240 290 375 270 325 178 Cut-outs 2) for 3NP43 50 130 224 11 NSE00525 174 198 Cut-outs 2) for 3NP44 50 162 270 11 NSE00526 177,5 267 1) h = distance from upper edge of panel cut-out to center of disconnector mounting. 2) Cover is placed open on the switchgear cabinet panel, for cover behind control cabinet panel: cut-out dimensions on request. 48 Siemens 2009

3NP, 3NJ4, 3NJ5 Fuse Switch Disconnectors 3NP Fuse Switch Disconnectors up to 630 3NP4 for power distribution 3NP40 70-0F for surface mounting and flush mounting " #! $ # # % 3NP40 75-0F with busbar adapter, deep, 40 mm, busbars of width 12 mm or 15 mm and thickness 5 mm or 10 mm $ # & # $ " &! # '! # 5 - '? 3NP40 75-1F with busbar adapter, flat, 40 mm, busbars of width 12 mm or 15 mm and thickness 5 mm or 10 mm 3NP40 76-0F with busbar adapter, flat, 60 mm, busbars of width 12 mm or 30 mm and thickness 5 mm or 10 mm 3NP40 76-1 with busbar adapter, busbars with a width of 12 mm to 30 mm and a thickness of 5 mm or 10 mm, flat, T and I profiles 3NP42 75-1 3NP42 76-1 3NP43 76-1 3NP44 76-1 with busbar adapter, busbars with a width of 12 mm to 30 mm and a thickness of 5 mm or 10 mm, flat, T and I profiles Type a b 1) c d e f 3NP42 75-1 184 243 83 2) 45.5 111 40 3NP42 76-1 184 243 83 2) 45.5 111 60 3NP43 76-1 210 288 97 48 125 60 3NP44 76-1 256 300 112 48 139 60 1) For BGV 3 plus dimension c of the cable lug covers (see next page). 2) The 3NY7 820 molded-plastic masking frame is used for depth compensation (below) when installed together with size 000 or size 00 in LPH distribution boards. Siemens 2009 49

3NP, 3NJ4, 3NJ5 Fuse Switch Disconnectors 3NP Fuse Switch Disconnectors up to 630 3NP4 for power distribution 3NY7 200 molded-plastic masking frame for 3NP40 7 for installation in any distribution board 3NY7 201 molded-plastic masking frame for 3NP40 7.- for 3NP40 7.-C01 3NY7 220 molded-plastic masking frame for 3NP42 for installation in any distribution board 215 40 130 NSE00527 3NY7 230 molded-plastic masking frame for 3NP43 for installation in any distribution board 3NY7 240 molded-plastic masking frame for 3NP44 for installation in any distribution board 3NY7 820 molded-plastic masking frame for one 3NP42 70 switch disconnector for installation in LPH distribution boards 3NY7 500 molded-plastic masking frame for one 3NP40 switch disconnector, left for installation in LPH distribution boards 3NY7 501 molded-plastic masking frame for one 3NP40 switch disconnector, right for installation in LPH distribution boards 3NY7 502 molded-plastic masking frame for two 3NP40 switch disconnectors for installation in LPH distribution boards NSE00221 208 46 64 47 6 5 -! > & " $ $ " &! $ $ " 229 3NY7 600 touch protection cover for installation in LPH distribution boards for 3NP40 76 switch disconnectors 3NY7 601 touch protection cover for 3NP40 75 and 3NP40 76 switch disconnectors 2 38 NSE0_01605 195 38 142 NSE0_01604 194 112 32 73 5 Cable lug cover for 3NP40 7 with flat connector, 3NY7 101 112 73 123 Cable lug cover for 3NP42 to 3NP44, 3NY7 121, 3NY7 131, 3NY7 141 Type a b c 3NY7 121 181 65 67 3NY7 131 207 79 50 3NY7 141 253 94 47 50 Siemens 2009

3NP, 3NJ4, 3NJ5 Fuse Switch Disconnectors 3NP Fuse Switch Disconnectors up to 630 3NP5 for extended technical requirements Dimensional drawings 3NP50 60, 160 for surface mounting 63 63 84 116 15 70 Ø5,8 173 97 196 34 165 31 97,5 NSE00226 3NP50 60, 160 with molded-plastic masking frame for any type of installation M8 22 36 36 134 19 228 uxiliary switch Type a b c d 3NY1 105 135 215 95.5 38 3NY1 115 135 215 95.5 38 3NY1 106 135 290 144.5 64 3NY1 108 135 290 144.5 64 3NY1 208 149 250 115 53.5 3NY1 107 molded-plastic masking frame 3NP50 60, 160 with fuse monitoring by 3RV1 motor starter protector, with plug-in connector For plastic frames Cut-out for 3NP50 60, with and without auxiliary switch Cut-out for 3NY1 208 mounting kit NSE00230 191 207,5 126,5 143 6 For metal frames Cutouts for 3NP5 Type Cover betw. assembly kit Panel cut-out min. Molded-plastic masking frame behind panel Type B H B H h 1) 3NP50 6 3NY1 105 2) 135 215 130 206 115 3NP50 6 3NY1 125 3NP52 6 3NY1 210 222 300 210 293 146 3NP53 6 3NY1 211 245 300 235 293 146 3NP54 6 3NY1 212 290 300 280 293 146 Molded-plastic masking frame in front of panel Type B H B H h 1) 3NP50 6 3NY1 105 135 215 130 205 115 3NP50 6 3NY1 208 149 250 143 191 -- 3NP52 6 3NY1 210 220 300 210 262 132 3NP53 6 3NY1 211 245 300 234 262 132 3NP54 6 3NY1 212 290 300 279 262 132 1) h = distance from upper edge of panel cut-out to center of disconnector mounting. 2) With standard molded-plastic masking frame behind panel and corresponding panel cutout, the standard switching capacity is reduced to the following C 23B values: at 400 V I e 160, at 500 V from I e 160 to 125 and at 690 V from I e 100 to 50. Siemens 2009 51

3NP, 3NJ4, 3NJ5 Fuse Switch Disconnectors 3NP Fuse Switch Disconnectors up to 630 3NP5 for extended technical requirements 3NP5. 60, 250 to 630 for surface mounting 3NP5. 60, 250 to 630 with fuse monitoring by 3RV motor starter protector, with plug-in connection ' " G 5 -! # >!! 3NP5. 60, 250 to 630 with molded-plastic masking frame, for installation B M K % $ & 1) Through hole for screw.! 5 -! Cut-out for 3NP52 60, 3NP53 60 and 3NP54 60 Type a b c d e f g h i 3NP52 60 207 202 130 93 62 176 38 41 11.5 3NP53 60 231 226 130 106 70 192 39 39 11.5 3NP54 60 276 271 200 111 85 207 40.5 40.5 11.5 k 1) l 1) m n o q r s t 3NP52 60 M10 M8 336 25 32 212 3.6 156 210 3NP53 60 M10 M10 352 25 25 228 4.4 180 234 3NP54 60 M10 M10 367 30 25 243 6 225 279 u w x y 3NP52 60 89.5 220 186.5 200.5 3NP53 60 105.5 245 202.5 216.5 3NP54 60 120.5 290 217.5 231.5 & & 3NP50 65, 160 with busbar adapter, busbars of width 12 mm and thickness 5 mm or 10 mm 3NP50 65, 160 with busbar adapter, with fuse monitoring by 3RV motor starter protector, with plug-in connector 3NP5. 60, 160 to 630 with electronic fuse monitoring, with plug-in connection and control cable 3NP50 60, 160 with electronic fuse monitoring, with plug-in connection and control cable 3NP5. 60, 250 to 630 with electronic fuse monitoring, with plug-in connection and control cable 52 Siemens 2009

3NP, 3NJ4, 3NJ5 Fuse Switch Disconnectors 3NP Fuse Switch Disconnectors up to 630 3NP5 for extended technical requirements Schematics Function for auxiliary contacts main contact elements with SENTRON 3NP4 and 3NP5 SENTRON 3NP fuse switch disconnector with fuse monitoring (with 3RV1 motor starter protector, with auxiliary switch 1 NO + 1 NC) Circuit diagram of main circuit!! 0 8 * 7 * Circuit diagram of auxiliary circuit!! #! 3 3 " 1 1 1 " $ " 5 - % # >.! * 9 0 Q1 = Fuse switch disconnector Q2 = Motor starter protector K1 = Contactor S1 = ON button S0 = OFF pushbutton F1 = Overload relay F2 = Control-circuit fuse SENTRON 3NP5 fuse switch disconnector with electronic fuse monitoring Schematic circuit diagram Version "" (open-circuit principle): uxiliary switches only pick up if fuse faulty and voltage is applied. Version "R" (closed-circuit principle): uxiliary contacts pick up as soon as voltage is applied and as long as fuses are intact. Siemens 2009 53

3NP, 3NJ4, 3NJ5 Fuse Switch Disconnectors 3NJ4, 3NJ5 In-Line Fuse Switch Disconnectors up to 1250 General data Overview 3NJ4 fuse switch disconnector Overview of all components and accessory parts: 3NJ4/3NJ5 in size 00 ll key product features at a glance Compliant with IEC/EN 60439-1, IEC/EN 60947-3 Voltage levels up to 690 V C Rated operational current from 160 to 1250 Fuse links according to DIN 43620 Part 1 can be used nickel-plated fuse blades are not permissible due to the high transfer resistance In open position safe from touch by the back of the hand (exception 3NJ56: IP00) Parking position for maintenance 1-pole or 3-pole switchable Vertical and horizontal mounting position Climate-proof Degree of protection IP30 with closed fuse carriers, IP10 with open fuse carriers (exception 3NJ56: IP00) 1 4 2 6 14 13 5 6 3 7 12 8 9 10 11 1 Cover 2 Terminal strip 3 Busbar terminal 4 dapter for 2 x NH00 5 Current transformer 6 Distance compensation 7 Connection module 8 Flat connector 9 Saddle terminal 10 Prism terminal 11 Box terminal 12 Cover 13 3NJ4/5 fuse switch disconnector Basic device size 00 14 uxiliary switch mounting kit 54 Siemens 2009

3NP, 3NJ4, 3NJ5 Fuse Switch Disconnectors 3NJ4, 3NJ5 In-Line Fuse Switch Disconnectors up to 1250 General data Overview of all components and accessory parts: 3NJ4/3NJ5 in sizes 1 to 3 1 3 3 2 10 4 5 6 7 8 9 1 2 3 4 5 Terminal strip Distance compensation uxiliary switch Connection module Flat connector 6 Stud terminal 7 V terminal 8 Box terminal 9 Cover 10 3NJ4/5 fuse switch disconnector Basic device size 1/2/3 Siemens 2009 55

3NP, 3NJ4, 3NJ5 Fuse Switch Disconnectors 3NJ4, 3NJ5 In-Line Fuse Switch Disconnectors up to 1250 General data Design 3NJ41 21 3NJ41 31 3NJ41 41 3NJ41 23 3NJ41 33 3NJ41 43 3NJ41 03 Inspection holes ll SENTRON 3NJ4/5 in-line fuse switch disconnectors are equipped like the complete SENTRON 3NJ series with voltage inspection holes for voltage testing. Mounting position The SENTRON 3NJ4/5 in-line fuse switch disconnectors can be mounted vertically or horizontally. When mounted horizontally, however, system-specific reduction factors and the coincidence factor (EN 60439-1 4.7 rated load factor) according to the applicable system regulations must be observed. Terminals L1 L2 L3 3NJ41 in-line fuse switch disconnectors SENTRON 3NJ4/5 in-line fuse switch disconnectors are designed like the complete SENTRON 3NJ series for mounting on 185 mm busbar systems. They are available in the following sizes and versions: Size 1 for 250, 1- or 3-pole switchable Size 2 for 400, 1- or 3-pole switchable Size 3 for 630, 1- or 3-pole switchable Size 4a for 1250, 1-pole switchable The size 00 for 160, 3-pole switchable in-line fuse switch disconnectors are available for 100 mm busbar center-to-center spacing and only as a special version for 185 mm busbar centerto-center spacing. Instead of one size 1 to 3 in-line fuse switch disconnector, two size 00 disconnectors with an adapter and masking frame can be used (see ccessories) on a 185-mm busbar system. The swiveling mechanism with 3-pole switchable disconnectors of sizes 1 to 3 is lockable and ensures simultaneous switching of all three phases. For size 4 the following versions are available in addition to the standard version: a slim version (W H = 248 775 mm) a special version (W H = 147 1115 mm) (delivery possibilities on request). ll SENTRON 3NJ4/5 in-line fuse switch disconnectors are fed by way of the busbars. The outgoing current is transported by cable, see adjacent graphic "Terminal positions"). With SENTRON 3NJ41 in-line fuse switch disconnectors it is possible to choose between having the cable connection on top or on bottom (standard version) by turning the contact carrier. The top part of these switch disconnectors can be removed completely. This ensures easy mounting. NSE0_00179a Terminal position Integration L1L2L3 ssembly kits as well as TT modules and partly equipped sideby-side cabinets are available for installation in the SIKUS 3200 (8GG) modular distribution board system; see Chapter "SIVCON Power Distribution Boards, Busway and Cubicle Systems" --> "Components for Distribution Systems". Installation in SIKUS Universal (8GF) is also possible. Please inquire. 56 Siemens 2009

3NP, 3NJ4, 3NJ5 Fuse Switch Disconnectors 3NJ4, 3NJ5 In-Line Fuse Switch Disconnectors up to 1250 General data Technical specifications Standards IEC/EN 60947-1, IEC/EN 60947-3 Type 3NJ41 0 3NJ41 2 3NJ41 3 3NJ41 4 3NJ41 8 3NJ41 5 3NJ56 3NJ5 0 Conventional thermal current Free air I 1) th 160 250 400 630 910 1000 1250 2) Enclosed I the 160 225 360 567 -- -- -- Rated insulation voltage U i V 750 1000 1000 1000 690 1000 1000 Rated operational voltage U e 40 Hz 690 690 690 690 400 690 690...60 Hz V C Rated conditional short-circuit current with fuses t 40 Hz to 60 Hz 690 V C k 80/50 110 110 110 50 110 80 (rms Max. rated current I n of the fuses 160 250 400 630 910 722 1250 Permissible let-through current of the fuses k 15 28 39 52 53 -- 80 (peak For fuse links acc. to IEC 60269-2 or isolating links Size/ 00/160 1/250 1 and 2 and 3/910 3/722 4a/1250 2/250 and 400 3/400 and 630 Rated operational current I e t 400 V C C-22B 160 250 400 630 910 1000 1250 t 500 V C C-22B 160 250 400 630 -- 1000 1250 t 690 V C C-21B 160 250 400 630 -- 1000 1250 t 690 V C C-22B 100 200 315 500 -- 600 -- t 220 V DC DC-21B 160 250 400 630 -- -- -- Rated breaking capacity t 500 V C p.f. = 0.65 480 750 1200 1890 -- 2400 3750 t 690 V C p.f. = 0.65 380 600 945 1500 -- -- -- t 220 V DC L/R = 1 ms 240 375 600 945 -- -- -- Capacitive switching capacity kvar 50... 60 105... 115 155... 185 250... 300 -- -- -- Rated short-time withstand current I CW k 14.5 14.5 14.5 14.5 14.5 14.5 14.5 (rms Permissible ambient temperature C -25... +55 Mechanical endurance Operating 1400 1400 800 800 800 800 800 cyc- les Electrical endurance Operating 200 200 200 200 100 100 100 cyc- les Degree of protection With closed fuse carrier, IP30 IP30 IP30 IP30 IP30 IP30 IP10 with terminal cover and peripheral cover With open fuse carrier IP10 IP10 IP10 IP10 IP10 IP10 IP00 Power loss of the main current paths at I th W 18 23 54 110 260 300 300 Main conductor connections Terminal screws M8 M10 M12 M12 2 M12 2 M12 M16 Flat bars mm 24 42 42 42 80 80 80 Cable lug, max. conductor cross-section (stranded) mm 2 95 240 240 240 3) 2 240 2 240 2 300 Tightening torque Nm 12... 15 30... 35 35... 40 35... 40 35... 40 35... 40 50... 60 Clamp/V terminals mm 2 1.5... 70 25... 300 25... 300 25... 300 -- -- -- Fixing screws M8 M12 M12 M12 M12 M12 M16 Required tightening torque for mounting on busbars Nm 16... 18 35... 40 35... 40 35... 40 35... 40 35... 40 50... 60 1) When several devices are used next to each other, the load factor according to EN 60439-1 Table 1 must be observed. 2) Required enclosure volume is at least 0.185 m 3. 3) special assembly kit is required for connection of 2 240 mm 2 ; delivery on request. Siemens 2009 57

3NP, 3NJ4, 3NJ5 Fuse Switch Disconnectors 3NJ4, 3NJ5 In-Line Fuse Switch Disconnectors up to 1250 1-pole switchable Dimensional drawings 3NJ50 13, 160 1-pole switchable 3NJ41.1-3, 250 to 630 1-pole switchable Type B 3NJ41 21 23 3NJ41 31 24 3NJ41 41 25 3NJ56 43, 1250 1-pole switchable for 185 mm center-to-center spacing Panel cut-out with flush mounting for 3NJ56 43 58 Siemens 2009

3NP, 3NJ4, 3NJ5 Fuse Switch Disconnectors 3NJ4, 3NJ5 In-Line Fuse Switch Disconnectors up to 1250 3-pole switchable Dimensional drawings 3NJ41 03-3BF02 3-pole switchable 122 50 87 249 Flat connectors top 3NJ41 03-3BR02 3-pole switchable 122 50 87 249 Flat connectors top 415 9x16 Ø 9 9x16 160 100 100 300 169 150 92 415 9x16 Ø9 9x16 160 100 100 17 22 55 58 85 20 90 300 169 150 92 3 4 18 19 6 45 73 120 Flat connectors bottom NSE0_01589 3 18 10 5 31 59 120 Flat connectors bottom NSE0_01590 3NJ41.3-3, 250 to 1000 3-pole switchable "ON" position "OFF" position unlocked locked Mounting of the in-line fuse switch disconnectors on busbars for 100 mm center-to-center spacing Mounting of the in-line fuse switch disconnectors on busbars for 185 mm center-to-center spacing Minimum distance between the conductive parts of all bars: 100 mm Type C 3NJ41 23 23 3NJ41 33 24 3NJ41 43 25 3NJ41 53 25 3NJ41 83 25 Siemens 2009 59

3NP, 3NJ4, 3NJ5 Fuse Switch Disconnectors 3NJ4, 3NJ5 In-Line Fuse Switch Disconnectors up to 1250 ccessories Dimensional drawings 3NJ49 12-200 blanking cover 50 mm wide for panel cut-out 3NJ49 12-3B01 blanking cover for busbar 100 mm wide for 185 mm busbars 99 20 36 3NJ49 12-3C00 blanking cover for busbar 50 mm wide for 100 mm busbars 50 2 NSE0_01882 98 64 3NJ59 74-0B busbar support 45 Ø11 M10 1) L1 cover plate made of plastic depth: 2 mm 185 185 633 185 410 185 L2 L3 28 572 100 M8 52 200 185 432 100 NSE0_00253a 185 NSE0_00250a 49,5 12 4,5 70 NSE0_1881 38 25 Width of busbars as required, but minimum clearance of 20 mm to the next busbar or conductive parts 1) Maximum screw-in length 14 mm, tightening torque 30 Nm. 3NJ49 11-300 busbar terminal 3NJ49 18-0E00 adapter for 60 mm busbar center-to-center spacing 3NJ49 18-0D02 adapter for 185 mm busbar center-to-center spacing 185 185 100 100 20,5 M8 99,6 50 SW 19 M12 2 36 52 23 450 NSE0_01588 3NJ49 12-1D02 cover (long) for 185 mm busbar center-to-center spacing NSE0_01591a 50 135 227 662 60 Siemens 2009

8US Busbar Systems General data Overview Design Function 8US busbar systems with 40 mm and 60 mm busbar center-tocenter spacing as well as flat copper profiles have now become Short-circuit strength firmly established on the world market. The permissible busbar temperature is a decisive factor when dimensioning the busbars. The busbar temperature is dependent on the current and the current distribution, on the busbar cross-section and the busbar surface, on the position of the busbars, convection and the ambient temperature. The values stated in the following table can only be considered as guide values because the conditions vary with each location. The values are based on uninterrupted current over the whole busbar length. The busbar runs prove most advantageous when the incoming supply is centrally located and the load is distributed symmetrically on both sides. 8US busbar systems are designed for horizontal mounting of the busbars. The short-circuit strength of the busbar system is dependent on the distance of the busbar supports and on the busbar cross-section. The short-circuit strength of the whole system is dependent on the short-circuit strength of the busbars and of the adapters with circuit breakers or switch disconnectors (see "Molded case circuit breakers (MCCB)" and "Switch disconnectors"). If one of these values is lower than the prospective short-circuit current at the place of installation, a current-limiting protective device has to be mounted upstream of the 8US busbar system. This may also be mounted as a feeder circuit breaker on the busbar system itself. Siemens 2009 61

8US Busbar Systems 40 mm Busbar Systems General data Overview The 40 mm busbar system is used in machinery and plant engineering, in motor control centers and in power distribution systems of the low performance range up to 400. The busbar cross-sections are adapted to the rated currents and are available in the sizes 12 x 5 mm, 12 x 10 mm, 15 x 5 mm and 15 x 10 mm. The basic system is configured without covers. If touch protection is required, this is possible with busbar covers. n optimized spectrum of busbar adapters and device holders offers numerous adaptation and mounting options. Terminals round off the product range of the 40 mm busbar system. 62 Siemens 2009

8US Busbar Systems 40 mm Busbar Systems Base assemblies Overview 2 1 3 4 5 1 Flat copper profile 4 Inlay part 2 3 Busbar support Cover profile 5 Covering cap Dimensional drawings 8US19 03-3B00 8US19 03-500 " # " # "! # # 5 - % ' #! Siemens 2009 63

f 8US Busbar Systems 40 mm Busbar Systems Infeed and connection components Overview Dimensional drawings 8US19 21-2..0. 8US19 22-1G00 b a c NSE0_00464 e d Type a b c d e f 8US19 21-20. -2B0. -2C0. -2D0. 8US19 21-2B0. -2BB0. -2BC0. -2BD0. 7.5 10.5 17 14.5 7.5 10.5 17 14.5 11.5 15.5 23.5 20.5 11.5 15.5 23.5 20.5 22.5 29 36 32 22.5 29 36 32 25 35 55 42 25 35 55 42 5 5 5 5 10 10 10 10 10 10 12 12 10 10 12 12!! " $ " $ 5 - " % = & " # # 64 Siemens 2009

8US Busbar Systems 40 mm Busbar Systems Busbar adapters and device holders Overview Dimensional drawings 8US10 51-5CM47 8US10 51-5DJ07 8US10 51-5DK07 8US10 51-5DM07 8US10 61-5DJ07 8US10 61-5FK08 8US10 61-5FM08 8US10 61-5FP08 " " & " & $ $ #!! ' # # 5 - " > & 5 - " > # # Siemens 2009 65

8US Busbar Systems 40 mm Busbar Systems Busbar adapters and device holders 8US10 11-4SL01 8US10 11-4TM00 15 73 182 200 NSE0_01594 " 30 40 40 5 15 8US11 11-4SM00!! 72 8US10 50-5K00 15 39 57 & " " $ $ % 8US10 50-5M00 " 5 - " " ' = " " $ $ " "! % $ % " $ 8US10 50-5RK07 8US10 50-5RM07 66 Siemens 2009

8US Busbar Systems 40 mm Busbar Systems Busbar adapters and device holders 8US10 60-5K00 8US10 60-5K08 8US10 60-5M00 8US19 98-2BK00 8US19 98-2BM00 Siemens 2009 67

8US Busbar Systems 40 mm Busbar Systems ccessories Dimensional drawings 8US19 21-2BF00 8US19 98-1B00 8US19 98-1C00 8US19 98-1D00 29 55 43 NSE0_01608 20 max. 28 8,5 8US19 98-400 8US19 98-7C08 8US19 98-7C10 8US19 98-7C15 % " % 5 - " & 29 7 74 90 27 29 9 14 NSE0_01599 35 8US19 98-7C16 8US19 98-8M07 8US19 98-810 68 Siemens 2009

8US Busbar Systems 60 mm Busbar Systems General data Overview The 60 mm busbar system is used preferably in control cabinet installation, in motor control centers and in power distribution systems of the medium performance range (630 ) and top performance range (1600, special profile). The 60 mm busbar system can be used as a basic system without covers, as a partly compartmented system or as a fully compartmented system with base. The busbar cross-sections are available in the sizes 12 x 5 mm to 30 x 10 mm and as a special profile. Busbar adapters for SIRIUS, 3VL circuit breakers, 3K and 3KL switch disconnectors, 3NP5 fuse switch disconnectors and 3NP4 directly mountable fuse switch disconnectors offers numerous options for configuring this busbar system. Incoming feeders, terminals and other accessories open up a large range of application. Busbars with a special profile are suitable for applications up to 1600. ll components of the 60 mm busbar system can be fitted. Siemens 2009 69

8US Busbar Systems 60 mm Busbar Systems Base assemblies up to 630 Overview Dimensional drawings 5SH3 506 5SH3 526 5SH3 527 230 75 NSE0_01600 290 125 60 60 68 NSE0_01603 68 70 Siemens 2009

8US Busbar Systems 60 mm Busbar Systems Base assemblies up to 630 5SH3 353 5SH3 354 5SH3 528 5SH3 530 5SH3 531 5SH3 532 5SH3 536 5SH3 537 NSE0_01601 NSE0_01602 200 200 60 60 9 32 49,4 62,5 62,5 Siemens 2009 71

8US Busbar Systems 60 mm Busbar Systems Base assemblies up to 630 8US19 22-1B00 8US19 22-1C00 with 8US19 23-301 8US19 22-200 8US19 22-2B00 5 31 5,2 10,2 L1 30,5 NSE0_00720 Length 1000 mm 30,5 NSE0_00721 Length 1000 mm 226 L2 L3 PE N NSF0_00212 25 25 8US19 22-2C00 8US19 22-1H00 8US19 23-201 5 17,5 1100 SECTION: - 100 60 215 NSF0_00213 11 15 86 NSF0_00214 60 30,5 100 8US19 23-301 8US19 23-400 8US19 23-500 NSE0_01567a 49,5 20 5 30,5 SECTION: - 75 12 33 6,5 11,5 37 191 60 60 NSE0_01606 150 164 60 20 NSE0_01568a 49,5 20 49 72 Siemens 2009

8US Busbar Systems 60 mm Busbar Systems Base assemblies up to 1600 Overview Dimensional drawings 8US19 22-2D00 NSE0_01607 34 31 1,5 8US19 43-300 5 - & % # 71 78 # ' 40 8US19 48-200!! " #! Siemens 2009 73

8US Busbar Systems 60 mm Busbar Systems Infeed and connection components Overview 74 Siemens 2009

8US Busbar Systems 60 mm Busbar Systems Infeed and connection components Dimensional drawings 8US12 00-000 8US19 21-100 8US19 21-1B00 250 60 94 60 250 60 194 200 60 194 f 81 NSF0_00210 32 81 54 32 NSE0_01598 8US19 21-2..0. b c a NSE0_00464 d e Type a b c d e f Max. tightening torque 8US19 21-20. -2B0. -2C0. -2D0. 8US19 21-2B0. -2BB0. -2BC0. -2BD0. 8US19 41-2C00 7.5 10.5 17 14.5 7.5 10.5 17 14.5 11.5 15.5 23.5 20.5 11.5 15.5 23.5 20.5 22.5 29 36 32 22.5 29 36 32 25 35 55 42 25 35 55 42 5 5 5 5 10 10 10 10 10 10 12 12 10 10 12 12 4 Nm 6 Nm 15 Nm 10 Nm 4 Nm 6 Nm 15 Nm 10 Nm 18 Nm 8US19 41-2C00 20 max.55 37 NSF0_00215 37 27,5 15 23,5 10 8US19 22-1G00 8US19 22-1G02 " $!! & " " $ # # 5 - " % = 8US19 41-202 # 5 - " $ % = 8US19 41-2B00 8US19 41-2BB00, 8US19 41-201 & # # "! " Max. tightening torque 30 Nm = N ' & Max. tightening torque 40 Nm Max. tightening torque 30 Nm Siemens 2009 75

" ' " 8US Busbar Systems 60 mm Busbar Systems Busbar adapters and device holders Overview Dimensional drawings 8US11 11-4SM00 8US12 10-404 & " " $ $!! % " 5 - " " ' = " " $ $ " "! % $ % " $ 8US12 11-4SL00 8US12 11-4SL01! # #! # # & + L H %! # " # $ $ # " # "! # % & # $ # 5 - & ' " 76 Siemens 2009

8US Busbar Systems 60 mm Busbar Systems Busbar adapters and device holders 8US12 10-4G00 Cover 8US12 10-4F00 Cover 8US12 11-4TM00 8US12 50-5M00 81 60 20 5 60 15 182 35 NSE0_01596 72 15 39 67 8US12 50-5RM07 Siemens 2009 77

8US Busbar Systems 60 mm Busbar Systems Busbar adapters and device holders 8US12 51-5CM47 8US12 51-5DM07 8US12 61-5FM08 8US12 60-5M00 8US12 60-5P00, 8US12 61-5FP08 8US19 27-4F00 8US19 27-4F01 " % # % % " " ' % # " & # " # % $ # # 5 - & ' # = $ " # # $! 8. #! 8 "! 8!! 8. " " N &! 8! 8! $ N! 8 " $ N '! 8 4 +,! #! ' # % " # % ' " N " $ # & " #! # " % # " # ' 8US12 91-4SB00 with 3NP50 Cover 8US19 98-2BM00 78 Siemens 2009

8US Busbar Systems 60 mm Busbar Systems Bus-mounting fuse bases Dimensional drawings 5SG6, 5SF6 bus-mounting fuse bases 5SG6 202 (t = 5 mm), 5SG6 203 (t = 10 mm) D02/63 (a = 27 mm) (t = bar thickness) 5SG6 204 (t = 5 mm), 5SG6 205 (t = 10 mm) D02/63 (a = 42 mm) 5SF6 014, 5SF6 015 (t = 5 mm), 5SF6 016, 5SF6 017 (t = 10 mm) DII/25 (a = 57 mm) 5SF6 214, 5SF6 215 (t = 5 mm), 5SF6 216, 5SF6 217 (t = 10 mm) DIII/63 (a = 42 mm) 60 60 177 60 60 177 60 60 169 a t 23 33,5 55 I2_07478a a t 23 33,5 55 I2_07498 a t 36 43,5 66 I2_07497 5SH covers for bus-mounting fuse base 5SH5 241 single D02/63 5SH5 242 1.33-fold 5SH5 243 double 5SH2 042 (single: a = 42 mm) 5SH2 043 (double: b = 84 mm) DII/25 5SH2 242 (single: a = 57 mm) 5SH2 243 (double: b = 114 mm) DIII/63 Siemens 2009 79

8US Busbar Systems 60 mm Busbar Systems ccessories Dimensional drawings 8US19 21-2BE00 NSF0_00211 SW 13 20 40 Max. tightening torque 15 Nm 12 8US19 21-2BF00 29 55 43 NSE0_01608 20 max. 28 8,5 Max. tightening torque 12 Nm 8US19 41-2BF00 45 32 ca.70 Max. tightening torque 30 Nm 8US19 98-1B00 8US19 98-1C00 8US19 98-1D00 8US19 98-400 8US19 98-7C08 % " % 90 5 - " & 110 NSE0_00469 29 7 74 90 27 29 9 14 NSE0_01599 35 8US19 98-7C10 8US19 98-7C15 8US19 98-7C16 8US19 98-8M07 8US19 98-810 80 Siemens 2009

Get more information Low-Voltage Controls and Distribution www.siemens.com/lowvoltage Siemens G Industry Sector Low Voltage Controls and Distribution Postfach 48 48 90026 NÜRNBERG GERMNY Subject to change without prior notice Siemens G 2009 www.siemens.com/automation