CREATED ON: January 06, 2015 OPERATING MANUAL FOR ANNUNCIATOR PANEL

Similar documents
AC-115 Compact Networked Single Door Controller. Installation and User Manual

WD-AMX Water Detection Controllers

RY2 miniature industrial relays

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

Digital Keypad Use s Manual

BARDIC. 4 & 8 Zone Fire Panels Zircon range. Data, installation, operation and maintenance. by Honeywell

Advantium 2 Plus Alarm

Inductive Sensors Single or Dual Loop Detectors Type LD with teach-in

13 SERIES. Electronic step relays A

Solid-State Timer H3G

I STAR COMPUTER CO., LTD

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

ETC TWO STAGE ELECTRONIC TEMPERATURE CONTROL

Fire Alarm Control Panel. Family. Operating Manual

Telefon (+45) Telefax (+45) Installation and operating manual

38 Series - Relay interface modules A

LINETRAXX VMD460-NA. Network and system protection (NS protection) for monitoring the power feed-in of power generation systems

Solid State Timers Type F

ALARM ANNUNCIATOR ME INSTRUCTION MANUAL

RM35UA13MW. range V. Main. Product or component type. Relay monitored parameters

LED - Indicator Panels

ACS-30-EU-EMDR-10-MOD

FLOW CALCULATOR INSTRUCTION MANUAL MESURES BAMOPHOX M1 02 E MES FLOW CALCULATOR /1

Section D..General Auto Electrical Corporation

38 Series - Relay interface modules A

Power Supply and Indicator Unit Type Fig. 1 Type Mounting and Operating Instructions EB 9539 EN

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q R0001

User s Manual Before using the inverter, you need to read and save the safety instructions.

Reyrolle Protection Devices. 7PG17 - XR Intertripping, Interposing, Supervision and Special Purpose Relays. Answers for energy

IO-DIM6 6-Channel, Digital to Analogue Converters

TMS TANK MANAGEMENT SYSTEM

User Manual. ATX12V / EPS12V Power Supply TG-I460R (460W+460W) TG-I550R (550W+550W) Switching Power Supply User Manual

650W Single Output Power Supply 15V 24V. 27V 48V Rated Current. 0 ~ 100A 0 ~ 50A 0 ~ 40A 0 ~ 27A 0 ~ 24A 0 ~ 13.6A Rated Power

Trip circuit supervision relay. Type RXTCS

Operating Manual for the Electronic Built-in Interval Timer. Micro II (Countdown Timer)

Thyristor-controlled power supplies and battery chargers

1000W Single Output Power Supply 15V 24V. Protection type: Total Power limit, Latch-style (Recovery after reset AC power ON or inhibit)

Features, Benefits, and Operation


HSP GmbH Zum Handwerkerhof Wendelstein Tel / Fax: / Web: HSP@hsshsp.de NTG-3000.

VIBRATION MONITORING OF FANS INSTALLED IN ROAD TUNNELS

Product and functional description

RM4TG20 three-phase network control relay RM4-T - range V

SKR - industry relay

Control Devices Catalogue. Control Devices. Preferred and Standard Products

COMPALARM AP GENERAL MAIN FEATURES

AUTOMATIC TRANSFER SWITCH CONTROL UNIT OPERATOR S MANUAL

HCS-3300/3302/3304 USB Remote Programmable Laboratory Grade Switching Mode Power Supply

EBDSPIR-PRM, EBDSPIR-PRM-IP

Galleon 6-10K Online UPS. Voltronic Power Technology Corporation

Owner s Manual AWM910 JENSEN AWM910 COMPACT DISC PLAYER RADIO CD COMPACT MUSIC SYSTEM MUTE AUX BAND AUX IN PUSH PUSH PWR VOL ALARM T/F AUD SPK A SPK B

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

Specifications H8CA-S H8CA-S RATINGS. Approved by the following standards CHARACTERISTICS

CO2 Alarm. Operation. Application

Disabled Toilet Alarm. Contractor Pack. Installation & Operating Instructions

A.1. a Division of Pittway Corporation. Documento: M MGAS-ENG. Edizione: 01/1997 Rev.:

DIGITAL ALARM II FOR HOSPITALS AND LABORATORIES INSTALLATION AND OPERATING INSTRUCTIONS

Fixed - Over/Under voltage limits, ( ) U N respectivity Link selectable - 5 min or 10 min delay. Fixed limits

REGULINE 600VA / 1000VA REGULATOR USER MANUAL

Solid-State Relays. Series Included. Solid-State Relays SIR SLR NLF PHS Series PHS...148

PAL to NTSC (NTSC to PAL) Converter with 19 inch Rack (CDM-640AR)

AZ420 MINIATURE GENERAL PURPOSE RELAY

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2...

CM705B - Universal Expander Module CM707B - Plug On Zone Expander Security Systems

HM-W536 Install Guide

Shutter Actuator Standard, 4-fold, 230 VAC, MDRC RA/S , GH Q R0111. ABB i-bus EIB

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

PB-600 series. 600W Single Output Battery Charger SPECIFICATION MODEL PB PB PB V 28.8V 57.6V 13.8V

INSTRUCTION MANUAL VRT-200. TECSYSTEM S.r.l. Via Cristoforo Colombo, 5/C Corsico (MI) phone / Fax:

TrueAlarm Fire Alarm Systems

Actuator for modulating control AME 435

Radiant Temperature Sensor TY7321

Technote. Frese OPTIMA Compact actuators DN10-DN32. Application. Features thermic actuators. Features motoric actuators. Approval.

LS1024B / LS2024B/ LS3024B. Solar Charge Controller USER MANUAL

RDJ10RF/SET. Wireless room temperature controller with 24-hour time switch and LCD. Programmable, for heating systems

FIREDEX Conventional Fire Panels

Programmable Room Thermostat 7 Day (5-2 Day) Models: / Power Supply: Battery / Mains

Installation & User Instructions

User Manual for CH-PFC76810

Reference V, 50 Hz A V,60 Hz V, 50/60 Hz A V, 50/60 Hz V, 50 Hz A V, 60 Hz

DRM75A 230V 20/100A DIN rail single phase two wire energy meter

*.ppt 11/2/ :48 PM 1

INSTALLATION/PROGRAMMING INSTRUCTIONS E4KP ENTRYCHECK

Switch Actuator, 8-fold, 10 A, MDRC AT/S , GH Q R0111

SMS GSM Alarm Messenger

38 SERIES. Relay interface modules A. EMR Electromechanical Relays. Common features. SSR Solid State Relays. 6.

GENERATOR START CONTROL MODULE - MINI (2 Wire to 3 Wire)

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N

Name Description Model Number. Parameters Min. Typ. Max. Note. Vaux Voltage 9.8 V 12 V 13.2 V Auxiliary Supply Voltage

FIRERAY 2000 Installation Guide

TEMON 8-C. Doc. N MO-0370-ING TEMPERATURE MONITOR DEVICE TYPE TEMON 8-C OPERATION MANUAL. Microener - Copyright 2010 FW 2.2 Date Rev.

Safety automation solutions

Fire Pump Controllers Remote Alarm Panels

OPERATING INSTRUCTIONS

EBDSPIR-DD, EBDSPIR-DD-IP

GST301. (Single Protection Zone) Operation Manual

O WA-120U series IP W Single Output Switching Power Supply. Features. Aplications

Speed Control Relays SX2

Installation and Operation Manual Back-UPS BX800CI-AS/BX1100CI-AS

Operating instructions for built-in electronic timers with Day and Week programms. Series 884

Transcription:

OPERATING MANUAL FOR ANNUNCIATOR PANEL

ANNUNCIATOR PANEL OPERATING MANUAL MODEL : CP-04 1.0 INTRODUCTION 1.1 General Description The Model CP-04 is an Annunciator panel with hooter & manual reset. 1.2 Specification : M2-8 Function : Programmable fault annunciator panel with hooter & manual reset. Rated supply Voltage : 240V AC ± 10% Rated Frequency : 50 Hz ± 5% Power consumption : 50VA / 10W No. of windows : 16 Fault input contacts : Selectable NO / NC type for every channel (Potential free contacts) Window Colour : Red Window size : 31.5mm X 27.5mm (LXW) Control output (No. of Relays) : 2 C & NO Trip contacts on Annunciator Contact rating : 1 C/O rated for 5A @ 250VAC / 28VDC resistive load Test facility : Provided (operational test) External Push buttons : Provided Ambient temperature : Operation : -10 C to + 55 C Storage : -25 C to + 80 C Humidity : MAX 85% RH @ 40 C Electrical life (under full load) : 10 5 operations minimum Insulation resistance : >100M ohms @ 500V DC Dielectric strength : 01) 2.5KV AC, 50Hz for 1 minute. ( Between current carrying & non current carrying parts) 02) 1.5KV AC, 50Hz for 1 minute. (Between contacts & control circuit ) 03) 750V AC, 50Hz for 1 minute. (Between non-continuous contacts of the relay) Electrical connections : Cage clamping terminals Dimension : 340 X 340 X 255 mm (LXWXD) Enclosure (series) : Wall mounting

2.0 FUNCTION M2-8 Is a Programmable fault Annunciator having features like programming input fault for window annunciating w.r.t NO or NC, output relay for either TRIP or ALARM function, 3.0 Testing of windows for working condition Apply Rated voltage at source terminals. SEL : To select the window for programming in PGM mode MUTE : To mute the relay during fault conditions in RUN mode NC/NO : Select NC or NO as input sensing in PGM Mode ACK : To Acknowledge the fault during fault conditions in RUN Mode RST RST : To set the default settings in PGM Mode. : To reset the fault, once fault is rectified in RUN mode T/NT : Select Trip Relay or Alarm Relay in PGM mode TEST : To test healthy condition of all windows in RUN mode 4.0 PROGRAMMING Short PGM ENABLE terminals at the rear. Slide the RUN / PGM switch to PGM Mode. Press SEL button, window 1 will glow. By pressing NC/NO button, the Red LED can be toggled from ON to OFF and vice versa. If the RED LED glows. Normally open is a healthy condition & fault sensing is Normally closed type. If RED LED is OFF Normally closed is a healthy condition & fault sensing is Normally open type. By pressing T/NT button, the GREEN LED can be toggled from ON to OFF and vice versa. If the GREEN LED glows the output is programmed for ALARM RELAY. And if the GREEN LED is OFF the output programmed is for TRIP RELAY. Press SEL button, now the second window shall glow and by pressing the NC/NO and T/NT buttons required fault input sensing and relay output can be programmed. Follow the above procedure for the rest of the windows. Once the programming of all the windows is over, remove short at P1 & P2 terminals, to save the program Slide the RUN / PROG switch to RUN Mode. 5.0 INSTALLATION Annunciator panel has been designed for wall mounting type. Four mounting clamps are provided at 4 corners of rear side. Mounting hole diameter:14 mm ± 0.5mm. 6.0 COMMISSIONING PRESET CONDITIONS OF ANNUNCIATOR All windows are programmed to ALARM RLY output. Input is programmed to Normally open NO as healthy condition to all windows. For Detailed Operating instruction of Annunciator refer Operating Manual of M2-8. Connect Power cables & Fault Input cables through Glands.Connection of potential free fault input Terminals shall be connected as per diagram. Switch on MCB inside the panel & ensure lamp L1 starts glowing to indicate power is ON. Turn ON/OFF selector switch SW in panel.ensure lamp L1 starts glowing to indicate Power is on. Red & Green LED s in annunciator starts blinking to indicate working status. Press Lamp Test button & ensure all windows of Annunciators are blinking & Hooter is ON. Press ACCEPT push button & ensure Hooter is OFF & windows are steady. Press RESET push button & ensure all windows are OFF.

7.0 OPERATION OF PANEL If fault is received at Annunciator, corresponding window starts flashing. Fault can be acknowledged by pressing PB ACCEPT Button & window becomes steady & Hooter Switches OFF.. Once Fault is rectified press PB RESET & window switches off. If fault is unattended,hooter shall go OFF after the set time (set the time using Knob & Switches) & Fault will continue to Flash in Respective window. Upon pressing ACCEPT button, Hooter Timer resets & ready for next operation. 8.0 CONNECTION DETAILS