Express fire equipment limited. Detection, Alarm Equipment & Emergency Lighting

Similar documents
Premier M Plus & Infinity 8

Disabled Toilet Alarm. Contractor Pack. Installation & Operating Instructions

FIREDEX Conventional Fire Panels

(68.52) X. June 2000 Supercedes February xenex CONVENTIONAL FIRE DETECTION & ALARM SYSTEM. we business differently

Analogue addressable devices

FIRE ALARM SYSTEM TECHNICAL SPECIFICATIONS Page 1 of 10

Conventional Fire Detection and Extinguishant Control System Specification

AlarmSense 2-wire detection and alarm system. Product Guide

BARDIC. 4 & 8 Zone Fire Panels Zircon range. Data, installation, operation and maintenance. by Honeywell

CB Zone Conventional Control Panel

QCS Section 23 Part 2 Fire Alarm and Detection Systems Page 1 2. FIRE ALARM DETECTION SYSTEMS...2

Technical Overview Add-on Sensors - Smoke Alarm. Get yours direct at:

Repeaters and Mimics Data Sheet

Fire & Security DETECTORS

GST301. (Single Protection Zone) Operation Manual

CB200W Water Leak Detection Panel Application Guide

CSP Combined Series. Telephone Door Entry. with. Proximity Keyfob Access

Drayton Digistat +2RF/+3RF

Fire detection equipment

MINERVA MX MX Virtual Multi-Sensor Detectors

AIS750 Series Alarm Annunciator

EVC40 EMERGENCY VOICE COMMUNICATION SYSTEM

Fire Detection Product Range

INTRODUCTION. The data provided is for The Standard Products and any variation will be dealt with at the end of this manual.

FIRE ALARM SYSTEM. A. Shop drawings shall be submitted as follows: 1. Manufacturer's published literature. for aspproval.

C E R T I F I C AT I O N LPCB B O A R D P R E V E N T L O S S. Cooper Fire Systems

Programmable Room Thermostat 7 Day (5-2 Day) Models: / Power Supply: Battery / Mains

3. MOUNTING THE FIRE ALARM PANEL PLANNING CABLE ENTRY 3.2 FIXING THE BACKBOX TO THE WALL

INSTALLATION GUIDE. Card Reader & Controller with KIM Swipe Reader for Solitaire 850 / 950 / 850L Learnlok PK2930

Addressable Fire Alarm Systems

Fire. The Fire Installers Mate. A guide to fire alarm systems design

conventional system operation

Communication A BRITISH MANUFACTURER. Features:

FIRERAY 2000 Installation Guide

BS5839 Part 1:2002 Overview

Detector transparent with Color Inserts. FAA 500 TR P Trim Ring transparent with Color Inserts. FCA 500 / FCA 500 E Detector Bases

DTW Works Master Specification Version 2006

TMS TANK MANAGEMENT SYSTEM

Emergency Voice Communication Systems EVCS Network 8 Data Sheet

HART HSSD High Sensitivity Smoke Detection

AC-115 Compact Networked Single Door Controller. Installation and User Manual

ACTIVE 5 ENGINEERING MANUAL

Smoke exhaust systems

Medical Lighting. XL4 Patient Light

LIGHTING FOR KITCHENS / UTILITY ROOMS / WORKSHOPS / KITCHEN CABINETS / GLASS CABINETS / FURNITURE

Gen4 Intruder Alarm Panels SIMPLY SECURE. For Residential & Small Commercial Applications

PS 29M DUAL CHANNEL BELTPACK IN METAL CASE

Emergency voice communications Product Name

HM-W536 Install Guide

SECTION DETECTION AND ALARM

MCR1900 Media Converter 19-Slot Chassis

IH E Sigma Island 90

FIRE ALARM SYSTEM TECHNICAL SPECIFICATIONS Page 1 of 19

PROFESSIONAL HOME ALARM SYSTEM. Important! Please read these instructions carefully.

Introduction. Refrigerant Leak Detecting System. Feature and Benefits

Signal Tower modulsignal50

TS510 & TS500. Installation & User Guide. Compatible Equipment

FIRE ALARM PANEL & SYSTEM OPERATION ID50 SYSTEM. The Fire Alarm System can be activated in the following ways :~

DCP Fan Controller. Version 01/2009. The engineer s choice

SECTION ZONED (DC LOOP) FIREALARM SYSTEM

SECTION FIRE ALARM AND SMOKE DETECTION SYSTEMS

600-GD & 600-GDL 600 SERIES GAS DETECTOR

2013 Wireless Video Intercom INSTALLATION GUIDE

SFC-200 SERIES FIRE ALARM CONTROL PANELS. SFC-200 Series Fire Alarm Control Panels. Features. Description

Mureva Assembly surface mounted wiring devices

Triple Waveband Infra-Red Flame Detection

Overview. Components of an alarm system Technology behind the equipment Communication Platforms Industry Terminology False Alarm Tips DSC products

IMPORTANT INSTRUCTIONS & OPERATING MANUAL. Houston 50 Inch Electric Wall Mounted Fireplace Black / White

D7050/D7050TH. Installation Instructions. Multiplex Photoelectric Smoke Detectors

Residential & Commercial Alarm Systems by Gross Security, LLC

2.8. Ex-Recess-mounted, ceiling emergency light fittings in compact metal design

COMPALARM AP GENERAL MAIN FEATURES

User Guide. Model Insulation Tester / Megohmmeter

welcome to our world fire alarm systems - series 600

Product and functional description

12 Volt 30 Amp Digital Solar Charge Controller Installation & Operation Manual

Linear Luminaire for Fluorescent Lamps Series EXLUX 6001

Building Control. Householder Guidance Leaflet No. 29. Fire detection in dwellings

SMOKE DETECTOR INSTALLATION PROGRAM The Burlington Ordinance Perspective

Wireless Alarm system s manual

The supplier and installer of the system should be approved by the local civil defence authority.

ALARMLINE ANALOGUE Linear Heat Detection System

Fire Alarm system Installation Guide

Manual for Fire Suppression & Methane Detection System

TS93 EMR T/PT/TDE. Surface applied door closer

500r+ Installation and User Guide

TrueAlarm Fire Alarm Systems

DC1100 & 1400 Energy Controllers. Satchwell DC1100 & DC1400 for energy-efficient temperature control in smaller buildings.

XUSL4E4BB091NS2 XUSL type 4 - Slave2 - For body protection - 4 Beams, Hp = 910 mm

VEGA Analogue Addressable Control Panels

ABB Stotz-Kontakt GmbH ABB safe&smart Project planning of security systems

MANUAL PC1000R

LD2 One & Two Zone Water Detection Alarm Installation and Operation Manual

Installation Handbook. Interactive Fire Alarm System Release 3. Repeater Panel BU-320 / Information Panel BV-320

FIRE DETECTION AND ALARM SYSTEMS

RGB Light Panel Applications. RGB LED Light Panel FEATURES & BENEFITS SPECIFICATION SHEET

FlexFlash Instruction Manual Models SB FLXFLSH400W, SB FLXFLSH200W, SB FLXFLSHE400W, SB FLXFLSHE200W

Instructions: Retain these instructions for future reference SmartChargePro35 RSCPR35-12v, 2 / 8 / 16 / 35A

PROTEC CIRRUS HYBRID ASPIRATING SMOKE DETECTION SYSTEMS

RESOLUX / HIGHLITE/ COMPACT LINE Technology Lighting as its best. Designed and produced in Germany

Transcription:

Express fire equipment limited. Detection, Alarm Equipment & Emergency Lighting

Contents 8W Bulkhead Emergency Light... 8W Mains Bulkhead Emergency Light... Recessed 8W Emergency Light... Recessed 8W Mains Emergency Light... 8W Mains Emergency Exit Box... 8W Maintained Emergency Exit Box... Hanging Maintained Emergency Exit Sign... Hanging Mains Emergency Exit Sign... Twin Non-Maintained Emergency Spotlight with 20W Halogen Lamps... LED Retro Fit Emergency Lighting Unit... Push Button Temporary Fire Alarm... Disabled Toilet Alarm Remote Indicator... Mains Reset Call Point... Mains Conventional Optical Smoke Detector... Mains Conventional Rate of Rise and Fixed Heat Detector... Puff Alert Cigarette Detector... 02 03 04 05 05 06 07 08 09 10 11 12 13 14 15 16 01

8W Bulkhead Emergency Light ELB01/ELB02 Legend Kit: The optional Legend Kit that can be used with both the ELB01, ELB02 and ELB04 Bulkhead Emergency Lights comprises of 4 individual stickers (shown below) which can be used in combination to display any exit sign. Product order code: ELBLEG The self-contained emergency lights comprise of a polycarbonate base and diffuser with a screw-free gear tray of metal construction. The unit is also fitted with a special air valve in the back box which provides ventilation when exposed to high temperatures. > Polycarbonate base and diffuser > Screw-free gear tray > IP65 > Self adhesive legend kit available > Over-charge and over-discharge protection Non-Maintained / Maintained Lamp Type Battery Emergency Duration ELB01 / ELB02 Non-Maintained / Maintained 220-240 AC T5 8W Fluorescent Tube 50Hz / 60Hz 8W Ni-Cd 2.4V 45Ah 3 Hours Width: 345mm Depth: 106mm Width: 76mm 02

8W Mains Bulkhead Emergency Light ELB04 > Polycarbonate base and diffuser > Screw-free gear tray > IP65 > Self adhesive legend kit available (ELBLEG) Lamp Type ELB04 220-240 AC 50Hz T5 8W Fluorescent Tube 50Hz 8W Width: 345mm Depth: 106mm Width: 76mm 03

Recessed 8W Emergency Light ELB03/ELB05 > Polycarbonate diffuser > Recessed Mounted > Over-charge and over-discharge protection Non-Maintained / Maintained Lamp Type Battery Emergency Duration ELB03 / ELB05 Non-Maintained / Maintained 220-240 AC T5 8W Fluorescent Tube 50Hz 8W Ni-Cd 2.4V 45Ah 3 Hours Width: 420mm Depth: 145mm Width: 100mm 04

Recessed 8W Mains Emergency Light ELB06 > Polycarbonate diffuser > Recessed mounted Lamp Type ELB06 220-240 AC 50Hz T5 8W Fluorescent Tube 50Hz 8W Width: 420mm Depth: 145mm Width: 100mm 8W Mains Emergency Exit Box ELEB05 > Polycarbonate legend panel (as depicted) > Robust steel box Lamp Type ELEB05 220-240 AC 50Hz T5 8W Fluorescent Tube 50Hz 8W Width: 392mm Depth: 190mm Width: 61mm 05

8W Maintained Emergency Exit Box ELEB04 > Polycarbonate legend panel (as depicted) > Robust steel box > Over-charge and over-discharge protection Maintained Lamp Type Battery Emergency Duration ELEB04 Maintained 220-240 AC 50Hz T5 8W Fluorescent Tube 50Hz 8W Ni-Cd 2.4V 4.5Ah 3 Hours Width: 392mm Depth: 190mm Width: 61mm 06

Hanging Maintained Emergency Exit Sign ELH01/ELH02/ELH03 > Available in Chrome, White or Brass > Aluminium frame > Polycarbonate legend > Robust steel ceiling mounted bracket > Over-charge and over-discharge protection Maintained ELH01 Chrome ELH02 White ELH03 Brass Maintained 220-240 AC 50Hz Lamp Type 5mm White LED x 14 50Hz 4W Battery Ni-Cd 3.6V 0.6Ah Emergency Duration 3 Hours Main body: Width: 408mm Height: 208mm Depth: 52mm Hanging chains: Height: 303mm Top unit: Width: 408mm Height: 33mm 07

Hanging Mains Emergency Exit Sign ELH04/ELH05/ELH06 > Available in Chrome, White or Brass > Aluminium frame > Polycarbonate legend > Robust steel ceiling mounted bracket ELH04 Chrome ELH05 White ELH06 Brass 220-240 AC 50Hz Lamp Type 5mm White LED x 14 50Hz 4W Emergency Duration 3 Hours Main body: Width: 408mm Height: 208mm Depth: 52mm Hanging chains: Height: 303mm Top unit: Width: 408mm Height: 33mm 08

Twin Non-Maintained Emergency Spotlight with 20W Halogen Lamps ELS01 > Robust steel housing > Can be top or bottom mounted > Over-charge and over-discharge protection Maintained Lamp Type Battery Emergency Duration ELS01 Non-Maintained 220-240V AC 50Hz 2 x 20W halogen lamps 50Hz 2 x 20W 2 x 12V 7Ah SLA 3 Hours Width: 310mm Depth: 325mm Width: 72mm 09

LED Retro Fit Emergency Lighting Unit ELBLED The Led Retro Fit Emergency Lighting Unit will fit virtually any 8 Watt emergency bulkhead fitting (both maintained and non-maintained). The unit is supplied complete with batteries in a clip-in housing. It is easy to fit the new LED unit, just remove the old 8 Watt tube, remove the lampholders and clip the new LED unit onto the gear tray, connect the mains cable and the job is complete. The unit complies with EN60598.22. The units can be quickly and easily fitted and has an average life of 50,000 hours compared with 9,000 for a conventional 8 Watt tube. Light Source Construction Battery Charge Current Size ELBLED High output voltage White LED Polycarbonate tray 4.8 Volt 900mA Nicad 50mA Nominal 230 Volt AC +10% -6% 50Hz 305mm x 60mm x 18mm 10

Push Button Temporary Fire Alarm ESA6 The push button temporary fire alarm is activated by pressing the button fixed on the front of the device. Once activated, the unit will sound and flash with a sound output of 85 decibels. The units can be used as a standalone unit or up to 32 units can be interconnected. > Standalone or interconnect up to 32 units > 85 decibels @ 3 metres with a flashing strobe alarm. ESA6 Operating Voltage 8 x AA batteries (12V DC) Average Current 10uA Alarm Current 200mA Sound Output 85 decibels @ 3 metres Strobe Colour Red Operating Temperature -10 C to + 50 C Minimum Continuous Temperature 0 C Maximum Humidity 95% RH Non Condensing Alarm Activation Manual (press button) Reset Manual (twist button) Number of interlinked units Up to 32 IP Rating IP35 Size Width: 230mm, Height: 230mm, Depth: 104mm Weight (including batteries) 850g 11

Disabled Toilet Alarm Remote Indicator DPTA01-06 > Simple 3 wire operation for all field devices > Control panel supporting up to 4 zones > Simple maintenance and fault diagnosis > On board buzzer in both Control Panel and Remote Indicator > Zone LED indication on control specification > Full range of field devices available (i.e. pull cord, remote reset and remote indicator) > A technical user manual is available for these products The Disabled Persons Toilet Alarms System is available as a single zone kit which can be expanded up to a maximum of 4 zones (where one zone is typically used for each individual toilet). The Disabled Person Toilet Alarm System meets the requirements of BS8300. Technical specification: Mains Quiescent Standby Current Maximum Overall Supply Current 230VAC 50Hz/60Hz 3mA DC (Buzzer Muted) 250 ma DC (Maximum) 12 Product order codes: Product Order Code DPTA01 DPTA02 DPTA03 DPTA04 DPTA05 DPTA06 DPTA07 DPTA08 DPTA09 Product Description Disabled Toilet Alarm 1 Zone Kit Disabled Toilet Alarm Control Panel Disabled Toilet Alarm Pull Cord Disabled Toilet Alarm Remote Reset Disabled Toilet Alarm Remote Indicator Disabled Toilet Sticker Disabled Toilet Alarm 2 Zone Kit Disabled Toilet Alarm 3 Zone Kit Disabled Toilet Alarm 4 Zone Kit

Mains Reset Call Point HOY010 The Mains Reset Call Point is a unique product that mimics the feel of breaking glass but the call-point can be re-set and re-used therefore improving environmental efficiency. An activation indicator drops into view at the top of the window after the reset Call Point has been operated. The unit is then simply re-set with a key and is ready for immediate re-use again. The Reset Call Point is suitable for indoor use only. Applications: The Reset Call Point is compatible with most conventional fire alarms systems and it is safe for use where glass cannot be used e.g. food processing plants, kitchens and swimming pools. As the unit can be quickly and easily reset, it is ideal for use in places that suffer from a high number of activations such as schools, prisons, shopping centres and other public places. > EN54-11 approved > Suitable for indoor use > Glass appearance maintains operator deterrence > Positive activation that mimics the feel of breaking glass > Visible warning flag confirms activation > Simple key to reset operating element (no broken glass) > Complete functional test with every activation Current rating Low current rating Housing and Mounting Box Material Electrical Contact Material Operating Temperature Installation Terminal Conductor Size Mounting IP Rating H0Y010 3 Amps 12 24V DC 1-100 ma 5 12V DC 0.1 Amps 125 250v AC Polycarbonate Silver Plated Brass -20 C to +65 C 0.5mm 2.5mm Flush or surface with back box IP32 Additional products for use with HOY010 Mains Reset Call Point: HOY011 Mains Reset Call Point Flush Mount Bezel HOY012 Mains Reset Call Point Cover (clear) HOY013 Mains Reset Call Point Key 13

Mains Conventional Optical Smoke Detector SD010 The Mains Conventional Optical Smoke Detector uses a pulsing IR LED and photodiode to detect IR scatter caused by smoke entering the chamber. The detector is particularly suitable for detecting optically dense smoke, involving materials such as soft furnishings, PVC, plastic, foam and all similar materials which produce small visible particles (from 0.5 to 10μm). The detector is supplied complete with an extra LED to improve detector identification in an alarm condition. The detector will work with most modern fire alarm control panels and comes supplied with a locking grub screw to prevent unauthorised head removal. > Designed to meet EN54 requirements > Attractive design > Dual LEDs for 360 visibility > Lockable base to stop unauthorised removal SD010 Detector Class Optical Smoke Design Standard EN54 Part 7 Approval DIFT Operating Voltage 9-33V DC Quiescent Current 65μA Alarm Current @ 24V DC 53mA MAX Operating Temperature -10 C to +50 C Minimum Continuous Temperature 0 C Maximum Humidity 95% RH non-condensing Alarm Condition 2.4% obscuration per metre Coverage 100m2 IP rating IP43 Start-up Time 10 Seconds Size: without base/with base 100mm x 37mm / 101mm x 53mm Weight: without base/with base 95g / 153g 14 Additional products for use with Mains Conventional Optical Smoke Detector SD010: SD012 Conventional Diode Base

Mains Conventional Rate of Rise and Fixed Heat Detector SD011 The Rate of Rise and Fixed Heat Detector uses a thermistor arrangement to sense a quick rise in temperature and also a final threshold temperature of 57 C. The detector has a single thermistor arrangement that gives an alarm at a temperature of 90 C. The detector has an extra LED to improve detector identification in alarm conditions. The detector will work with most modern fire alarm control panels and comes supplied with a locking grub screw to prevent unauthorised head removal. > Designed to meet EN54 requirements > Lockable to base to stop unauthorised removal > Remote LED output > Dual LEDs for 360 visibility SD011 Detector Class Rate of Rise and Fixed Heat Detector Design Standard EN54 Part 5 Approval DIFT Operating Voltage 9-33V DC Quiescent Current 40μA Alarm Current @ 24V DC 34mA Operating Temperature -10 C to +50 C Maximum Continuous Temperature 0 C Maximum Humidity 95% RH non-condensing Alarm Condition Rate of rise or fixed heat trigger @ 57 C Coverage 50m2 IP Rating IP43 Start-up Time 10 Seconds Size: without base/with base 100mm x 48mm / 101mm x 64mm Weight: without base/with base 75g / 133g Additional products for use with Mains Rate of Rise and Fixed Heat Detector SD011: SD012 Conventional Diode Base 15

Puff Alert Cigarette Detector CD01 > 3 sensitivity settings > Interconnection facility > LED & Piezo alarm warnings > Alarm silence button > Auto resetting alarm when smoke clears > Choice of fast or slow pattern for alarm tone > Test button > Low battery warning > Detector attaches to mounting plate for ease of installation > Locking peg to deter unauthorised removal > Remote indicator included > 5 year lithium battery included The Puff Alert Cigarette Detector has a remote indicator which is hardwired to the detector and is typically installed in an alternative location such as above the no smoking room or in a manager s office. The remote indicator will sound & flash should the cigarette detector be triggered. Both the detector & remote indicator are supplied with integral 5 year guaranteed lithium battery. Technical specification (CD01 only excluding LED indicator): Operating Voltage 9V DC Quiescent Current 7μA Alarm Current 35mA Max Alarm Output 85dB @ 1 metre Alarm Reset Will reset when the smoke clears Alarm LED Colour Red Operating Temperature -4 C to +50 C Minimum Continuous Temp 0 C Maximum Humidity 95% RH Non Condensing IP Rating IP43 Size Diameter: 105mm, Depth: 50mm Weight 177grams (including battery) CD01 Stand Alone Puff Alert Cigarette Detector and Remote Indicator 16