AVID. Three-Way and Four-Way solenoid valves and accessories. Flow Control. AVID Model 791 Solenoid Valve. Total Flow Control Solutions

Similar documents
3 WAY (3/2) POPPET VALVES FOR AIR AND VACUUM SERVICE SOLENOID OR AIR ACTUATED BROCHURE N-223

% ^ ) 0.55 W Low Power Solenoid Valves Aluminum, Brass, or Stainless Steel Bodies 1/4" to 1" NPT. 2/2 3/2 4/2 5/2 5/3 SERIES Low Power

Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv)

2 WAY (2/2) AND 3 WAY (3/2) BRASS AND STAINLESS STEEL SOLENOID VALVES

Centro-Matic Automatic Lubrication Systems System Controls

5 Port Pilot Operated Solenoid Valve Rubber Seal. Specifications Fluid Operating pressure range. 2 position single/3 position 2 position double

Electrically operated valves Series M-05, 3/2-, 5/2- and 5/3-way G1/8 650 and 750 Nl/min (0.661 and Cv)

4 Posiflow Proportional Solenoid Valves

Inrush Apparent power (VA) Flow Characteristics/Weight. Port size Rc. Valve model VS VS VS VS VS

type V46, solenoid or pneumatic operated

4/2-Way Pneumatic Solenoid Valve

3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics

Single sub-base valve

Unit 24: Applications of Pneumatics and Hydraulics

97300 NAMUR series, 3/2 & 5/2 Indirect solenoid actuated spool valve

STC 2P050 Series Solenoid Valves NSF Compliant Materials, 2 Way, Direct Acting

Assisted lift operated 2/2-way solenoid valves Type EV250B

2.12. page Products for Explosion hazardous Environment

3/2, 5/2, 5/2 bistable and 5/3 way pneumatic solenoid valve

Valves. Sub-Base Mounted Valves to ISO 5599/2

Baumann Way Bronze or Stainless Steel Control Valve

Non-Code Liquid Relief, ASME Section VIII, Air/Gas and Steam, National Board Certified, Safety and Relief Valves

Fisher 657 and 667 Diaphragm Actuators

Cartridge Valves. Solenoid Valves. Vickers. Screw-in Cartridge Valves. Maximum Pressure 210 bar (3000 psi) Maximum Flow 227 l/min (60 USgpm)

3/2-way Solenoid Valve, direct-acting, NC or NO

STC 3S A Series Solenoid Valves

3/2, 5/2, 5/2 bistable and 5/3 way pneumatic solenoid valve

5 Port Pilot Operated Solenoid Valve Metal Seal, Body Ported. Flow characteristics 1 4/2 (P A/B) 4/2 5/3 (A/B R1/R2)

Baumann Mikroseal Control Valve

Norbro Series 40R Pneumatic Actuator Double Acting or Spring Return

3 Port Solenoid Valve

UM/ /2 or 5/3 Solenoid and air pilot actuated soft spool valves

High Flow High Pressure Solenoid Valve. Double 3/2 N.C. solenoid valve with manual override

Solenoid Valve Type 3962

On-off valves MS-EM/EE, MS series, NPT

HOW TO ORDER SAFETY PRODUCTS/SAFETY CONTROL SYSTEMS ELECTRICAL SAFETY CONTROLS

SPOOL & SLEEVE VALVES solenoid air operated monostable / bistable function threaded ports G 1/8-G 1/4

Specifications. Model Flow type Pressure type. Air Maximum operating pressure. 1.0 MPa Ambient and fluid temperature. 3% F.S.

Electro-pneumatic control valves

Recognizing and understanding schematic symbols will enable you to comprehend a circuit s function.

BERMAD Waterworks. Quick Active Check Valve. 700 Series. Model 740Q. Features and Benefits. Major Additional Features

Coil Classification: Class F standard, Class H available Class B standard on V9xx models

SOLENOID VALVES AND PNEUMATIC VALVES

2 position single. (Standard) 100V AC 50/60Hz 200V AC 50/60Hz 24V DC. 2 position double

Fisher 377 Trip Valve

S GATE KNIFE GATE VALVE WITH PNEUMATIC ACTUATOR

Fluid. Flu. Fluid Fluid. uid Power d Power P. Fluid Power P. Fluid Power. Fluid Power Power. d Power. Directional Cetop Valves DCV 03.

C 50 μm filtered air, with or without lubrication spool 10 bar G/18 G1/4 6,5 8,5 890

Model 4418F. Overview. Typical applications. Key features and benefits. Accreditations. Starting air/gas valve Vented fuel gas valve

WILROY. Operation. Optional Diaphragm Rupture Detection HYDRAULICALLY ACTUATED DIAPHRAGM PUMP

Sensors. Sensors. All Cylinders. Specifications. Features: Features Type REED HALL EFFECT NPN or PNP. Ø8mm - 125mm

System 8. ü ( System 8

SKP Series SKP15U.. Gas Valve Actuator with Safety Shutoff Function

VSO MAX HP High Flow Proportional Valve

Electro-Pneumatic Bus Door Control Mechanism

2/2 and 3/2 Way Size 6 Seat Valves

3-Way heavy duty flow control, with pressure compensated and solenoid controlled priority flow

Shut-off & Lockout Valves 1/4" to 1-1/2" port size

Solenoid valves Type EVU

Proportional pressure regulators VPPE

IMPORTANT DOCUMENTATION DO NOT DISCARD!

System 6000 Electropneumatic Converter for Direct Current Signals Type 6116 i/p Converter

4 Dynamic Solutions. Leadership and Innovation in Valve Products and Valve Systems

Valv-Powr Series VPVL Stainless Steel Model D Double-Acting and Spring-Return Rack-and-Pinion Compact Pneumatic Actuators

G1/4 Q8. Standard with biased position

Mustang Series PRESSURE REDUCING CONTROL VALVE WITH PRESSURE SUSTAINING FEATURE. M115-2 (Globe) M (Angle) Schematic. Standard Components

Solenoid Valve Island Type 3965

RPE3-04. Functional Description HA /2010. Directional Control Valves Solenoid Operated. Replaces HA /2007

How To Drive A Compact Serie 1

Scraper Passage Indicator. Electrical Indicator. Features

Oildyne. 165 Series Hydraulic Power Units. Pressures to 241 bar (3500 psi) Flows to 5.4 lpm (1.4 gpm)

BURSTCHECK LINE OF RUPTURE DISC BURST INDICATORS

2-Way heavy duty flow control, with pressure compensated, solenoid and load sensing controlled priority flow

PNEUMATIC MARINE PRODUCTS FOR PROPULSION CONTROL

CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (4-20 ma Input Version)

*Rated to 207 Bar/3000 PSI with Aluminum Body. Denotes New Winner s Circle Product Line. Catalog HY /US

LINEAR MOTION CONTROL

Tyco PremiAir Pneumatic Actuators

IOM SERIES 820-E/P Electro-Pneumatic Positioner

Pressure Relief. Pressure Relief and Sequence Valves CG2V-6/8, 10 Series; CG5V-6/8, 20 Series. Vickers. Features and Benefits.

167D Series Switching Valves

Denotes New Winner s Circle Product Line. Catalog HY /US SERIES CAVITY DESCRIPTION FLOW PRESSURE PAGE NO. LPM/GPM BAR/PSI HIGH FLOW VALVE FAMILY

3/2-way Mini Solenoid Valve

BERMAD Waterworks. Pressure Relief/Sustaining Valve. 700 Series. Model 730. Features and Benefits. Major Additional Features

3/2-way pneumatic cartridge solenoid valve

UM/ /2 & 5/3 valves, solenoid and pilot actuated ISO , ISO size 1, 2, 3 & 4 Sub-base mounted

MTI10 Insertion and MTL10 In-line Thermal Mass Flowmeter and Temperature Transmitter

Check Valves. Pilot Operated Check Valves. Vickers. PCGV-6/8, 10 Series; PCG5V-6/8, 20 Series. Typical Section. Features and Benefits

Pneumatic Marine Products for Propulsion Control. The Drive & Control Company

ABV20 Air Actuated Boiler Blowdown Valve Installation and Maintenance Instructions

15/40/80CN Series Coreless Medium Pressure Filters

VP23, 3-way proportional pressure control valves Seat valve with μp-driven pressure control

solenoid valves SV Series 2- and 3-way Solenoid Valves for Gas and Liquid

Chapter 6: Check Valves

3 Port Solenoid Valve

Fisher D3 Control Valve

PRESSURE REDUCING CONTROL VALVE

Solenoid valves 2/2-way direct-operated Type EV210A

A descriptive definition of valve actuators

I nstallation. M100Q Series Proportional Actuator with R81Q Controller Board for Thermistor Sensor Applications. Tools Needed.

Transcription:

AVID Three-Way and Four-Way solenoid valves and accessories Features NEMA 4 or NEMA 4, 7, and 9 Explosion Proof ratings available. 5/2, 5/3 or 3/2 functions available. Flexible Lip seal ensures reliability and long service life. Class F coil is standard for NEMA 4 units. Class H coil is standard for NEMA 7 units. Manual override capability simulates solenoid coil operation. Continuous duty. Air supply filtered, lubricated or non-lubricated. High flow rates. Direct mounting to all Tyco Rack and Pinion actuators with stainless steel fasteners. Remote mounting via sub-base. Specifications Body - Aluminum Coil Housing - NEMA 4-Steel or Epoxy Molded (DIN) enclosure; NEMA 4, 7, and 9, IP65/CSA UL listed explosion proof CRS construction Electrical Connection - /2 NPT conduit entry standard, DIN connection available Air Connections - Supply: /4 NPT (Port ) Exhaust: /8 NPT (Ports 3 and 5) Keystone mounting /4 NPT (NAMUR and inline) Flow: Three Way - 0.055 C v Four Way Keystone Mounting - 0.7 C v Four Way Inline - NAMUR.8C v NBR Seals Operating Pressure 35 psig Min. to 50 psig Max. Temperature Ratings Ambient: -20 F to 50 F Coil Heat Rise: -85 F Flow Control Total Flow Control Solutions -US-030

The Model 79 Solenoid valve, four-way version, is a four-way, two-position solenoid operated, spring return valve. Its flexible lip seal design allows for positive shifting of air flow and constant cleaning of the spool with each shift, enabling the valve to stroke millions of trouble-free cycles. Directional Control When the solenoid operator is energized, the solenoid coil creates a magnetic field surrounding the plunger assembly and plunger. The plunger is lifted off its seat by this magnetic force and supply air provides an internal pilot pressure that is directed to the pilot piston that shifts the spool and compresses the main spring. This shifting of the spool directs the flow of supply air from inlet port to cylinder port 4 while cylinder port 2 is connected to exhaust port 3. When the solenoid coil is de-energized, a spring on the plunger will return the plunger to its seat, blocking internal pilot air, and open a vent port. This vent port will allow the air on the spool s pilot piston to excape, and the main spring will return the spool to its normal position. In this position, the spool directs flow of supply air from inlet port to cynlinder port 2 while cylinder port 4 is connected to exhaust port 5. Mounting The L version valve is intended for use on all Tyco Valves & Controls rack and pinion actuators that incorporate the standard Tyco accessory directional control valve mounting pad (.34 x 2.00 rectangle with 0-32 threaded holes); N version for NAMUR; and the P version for line mounting with Morin and Biffi Scotch Yoke actuators. Flow Diagrams (Note - Cylinder ports 2 and 4 are to actuator) Solenoid Operator is De-Energized 3 IN 5 2 4 Solenoid Operator is Energized 3 IN 5 2 4 2

C E 79N NAMUR Mounting (Four-Way and Three-Way Two Position) Four- and Three-Way two-position solenoid valve with interface according to VDI/VDE 3845 (NAMUR) for use on double or single acting pneumatic actuator. 4/2 or 3/2 way function by moving brass pilot plug Exhaust feedback in closed loop function (hi-flow three-way) Exhaust air can be throttled in 4/2 way function, thus actuator speed can be extended (exhaust throttle option) Manual override Continuous duty Air supply: filtered, lubed or non-lubed NBR Seals Three-Way Mounting 2.60 0.94 0.47 0.22 Dia. Mtg Holes 0.60.26 0.22 Dia. x 0.3 Deep Locating Hole 0 2 Four-Way Mounting Extended Turn Override Plug Placed here for 5/2 Operation 3 Three-Way Schematic Symbol.65 709-9AA 67 V DC 4.8 W 0 V 50/60 Hz 8.5/6.9 VA 00% ED 0 BAR 50 PSIG 2 4 4 6. 3 5 Four-Way Schematic Symbol.00 4 5 3 0.50 0.88 0.88 0.22 Dia. Mtg Holes Three-Way Explosion-Proof.26 0.94 Plug Placed here for 3/2 Operation 0.63 0.47 0.22 Dia. 3x Locating Hole Four-Way Explosion-Proof Voltages available: Protection class: Connector: Ambient temperature: Air connection: 0/60 0/50 VAC 245/60 220/50 VAC 24/60 22/50, 24, 0 VDC NEMA 4/4X or NEMA 4/4X/7/9 /2 Conduit or DIN Connection -20 F up to +50 F [-30 C up to +66 C] /4 NPT Pressure Port Air pressure: 50 psig Rated C v : Three-Way 0.06 Inlet 0.3 Exhaust Four Way.8 Four way with plug set to.8 Inlet three-way configuration 0.5 Exhaust 3

79N NAMUR Mounting (Three-Way Two Position) Model Numbers and Ordering Information Model NEMA Solenoid Voltage Number Rating Connection AC AC DC 60HZ 50HZ Three-Way, DIN Connection, Single Solenoid Spring Offset 79N-3-D4AA-00 4/4X - IP 65 According to DIN 43650 form A 0 0 79N-3-D4AB-00 4/4X - IP 65 According to DIN 43650 form A 245 220 0 79N-3-D4DA-00 4/4X - IP 65 According to DIN 43650 form A 24 22 79N-3-D4DB-00 4/4X - IP 65 According to DIN 43650 form A 24 Three-Way, Conduit Connection (DIN Style Solenoid), Closed Exhaust - High Flow, Single Solenoid Spring Offset 79N-5-D4AA-0 4/4X - IP 65 /2 Conduit w/30 leads 0 0 79N-5-D4AB-0 4/4X - IP 65 /2 Conduit w/30 leads 245 220 0 79N-5-D4DA-0 4/4X - IP 65 /2 Conduit w/30 leads 24 22 79N-5-D4DB-0 4/4X - IP 65 /2 Conduit w/30 leads 24 Three-Way, Conduit Connection (Steel Housing), Single Solenoid Spring Offset 79N-3-C4AA-00 4/4X - IP 65 /2 NPT w/24 leads 0 0 79N-3-C4AB-00 4/4X - IP 65 /2 NPT w/24 leads 245 220 0 79N-3-C4DA-00 4/4X - IP 65 /2 NPT w/24 leads 24 22 79N-3-C4DB-00 4/4X - IP 65 /2 NPT w/24 leads 24 Three-Way, Conduit Connection, Closed Exhaust - High Flow, Single Solenoid Spring Offset 79N-5-C4AA-00 4/4X - IP 65 /2 Conduit w/30 leads 0 0 79N-5-C4AB-00 4/4X - IP 65 /2 Conduit w/30 leads 245 220 0 79N-5-C4DA-00 4/4X - IP 65 /2 Conduit w/30 leads 24 22 79N-5-C4DB-00 4/4X - IP 65 /2 Conduit w/30 leads 24 Three-Way, Explosion Proof, Single Solenoid Spring Offset 2 79N-3-CXAA-00 4/4X - IP 65 /2 NPT w/24 leads 0 0 79N-3-CXAB-00 4/4X - IP 65 /2 NPT w/24 leads 245 220 0 79N-3-CXDA-00 4/4X - IP 65 /2 NPT w/24 leads 24 22 79N-3-CXDB-00 4/4X - IP 65 /2 NPT w/24 leads 24 Three-Way, Explosion Proof, Conduit Connection, Closed Exhaust - High Flow, Single Solenoid Spring Offset 2 79N-5-CXAA-00 4/4X - IP 65 /2 Conduit w/30 leads 0 0 79N-5-CXAB-00 4/4X - IP 65 /2 Conduit w/30 leads 245 220 0 79N-5-CXDA-00 4/4X - IP 65 /2 Conduit w/30 leads 24 22 79N-5-CXDB-00 4/4X - IP 65 /2 Conduit w/30 leads 24 Notes. DIN connectors are ordered separately; see options section on page 6. 2. Explosion Proof valves MUST have voltage specified on order. 4

79N NAMUR Mounting (Four-Way Two Position) Model Numbers and Ordering Information Model NEMA Solenoid Voltage Number Rating Connection AC AC DC 60HZ 50HZ Four-Way, Conduit Connection, Single Solenoid Spring Offset 79N-4-D4AA-00 4/4X - IP 65 According to DIN 43650 form A 0 0 79N-4-D4AB-00 4/4X - IP 65 According to DIN 43650 form A 245 220 0 79N-4-D4DA-00 4/4X - IP 65 According to DIN 43650 form A 24 22 79N-4-D4DB-00 4/4X - IP 65 According to DIN 43650 form A 24 Four-Way, Conduit Connection (DIN Style Solenoid), Single Solenoid Spring Offset 79N-4-D4AA-0 4/4X - IP 65 /2 Conduit w/30 leads 0 0 79N-4-D4AB-0 4/4X - IP 65 /2 Conduit w/30 leads 245 220 0 79N-4-D4DA-0 4/4X - IP 65 /2 Conduit w/30 leads 24 22 79N-4-D4DB-0 4/4X - IP 65 /2 Conduit w/30 leads 24 Four-Way, Conduit Connection (Steel Housing), Single Solenoid Spring Offset 79N-4-C4AA-00 4/4X - IP 65 /2 Conduit w/24 leads 0 0 79N-4-C4AB-00 4/4X - IP 65 /2 Conduit w/24 leads 245 220 0 79N-4-C4DA-00 4/4X - IP 65 /2 Conduit w/24 leads 24 22 79N-4-C4DB-00 4/4X - IP 65 /2 Conduit w/24 leads 24 Four-Way, Explosion Proof, Single Solenoid Spring Offset 2 79N-4-CXAA-00 4/4X/7/9 - IP 65 /2 Conduit w/24 leads 0 0 79N-4-CXAB-00 4/4X/7/9 - IP 65 /2 Conduit w/24 leads 245 220 0 79N-4-CXDA-00 4/4X/7/9 - IP 65 /2 Conduit w/24 leads 24 22 79N-4-CXDB-00 4/4X/7/9 - IP 65 /2 Conduit w/24 leads 24 Notes. DIN connectors are ordered separately; see options section on page 6. 2. Explosion Proof valves MUST have voltage specified on order. 3. Interface blocks are available to convert 79N solenoids to pipe-mounted solenoids. 5

79N NAMUR Mounting (Four-Way Three Position) Four-Way three-position solenoid valve with interface according to VDI/VDE 3845 (NAMUR) for use on double or single acting pneumatic actuator. Exhaust air can be throttled thus actuator speed can be extended (exhaust throttle option) Manual override Continuous duty Air supply: filtered, lubed or non-lubed NBR Seals Plug Placed here for 5/3 Operation Manual Override.65 2.40 0.20 7.00 (2) #0-32 Screws x.25 Long 4 5 3 24 Lead Wire Explosion Proof version shown 0.50 0.88 0.88 0.22 Dia. Mtg Holes 0.94 Plug Placed here for 3/3 Operation 2 4 4.26 0.63 0.47 0.22 Dia. x.3 Deep Locating Hole 3 Four-Way, three position, blocked center schematic symbol 5 Voltages available: Protection class: Connector: Ambient temperature: Air connection: Air pressure: Rated C v :.4 0/60 0/50 V AC 245/60 220/50 VAC 24/60 22/50, 24, 0 VDC NEMA 4/4X or NEMA 4/4X/7/9 /2 Conduit or DIN Connection -20 F up to +80 F [-30 C up to +82 C] /4 NPT Pressure Port 50 psig 6

79N NAMUR Mounting (Four-Way Three Position) Model Numbers and Ordering Information Model NEMA Solenoid Voltage Number Rating Connection AC AC DC 60HZ 50HZ Four-Way, DIN Connection, Dual Solenoid Spring, Centered - Blocked Center 79N-432-D4AA-00 4/4X - IP 65 According to DIN 43650 form A 0 0 79N-432-D4AB-00 4/4X - IP 65 According to DIN 43650 form A 245 220 0 79N-432-D4DA-00 4/4X - IP 65 According to DIN 43650 form A 24 22 79N-432-D4DB-00 4/4X - IP 65 According to DIN 43650 form A 24 Four-Way, Conduit Connection (DIN Style Solenoid), Dual Solenoid Spring, Centered - Blocked Center 79N-432-D4AA-0 4/4X - IP 65 /2 Conduit w/30 leads 0 0 79N-432-D4AB-0 4/4X - IP 65 /2 Conduit w/30 leads 245 220 0 79N-432-D4DA-0 4/4X - IP 65 /2 Conduit w/30 leads 24 22 79N-432-D4DB-0 4/4X - IP 65 /2 Conduit w/30 leads 24 Four-Way, Conduit Connection (Steel Housing), Dual Solenoid Spring, Centered - Blocked Center 79N-432-C4AA-00 4/4X - IP 65 /2 Conduit w/24 leads 0 0 79N-432-C4AB-00 4/4X - IP 65 /2 Conduit w/24 leads 245 220 0 79N-432-C4DA-00 4/4X - IP 65 /2 Conduit w/24 leads 24 22 79N-432-C4DB-00 4/4X - IP 65 /2 Conduit w/24 leads 24 Four-Way, Explosion Proof, Dual Solenoid Spring, Centered - Blocked Center 2 79N-432-CXAA-00 4/4X/7/9 - IP 65 /2 Conduit w/24 leads 0 0 79N-432-CXAB-00 4/4X/7/9 - IP 65 /2 Conduit w/24 leads 245 220 0 79N-432-CXDA-00 4/4X/7/9 - IP 65 /2 Conduit w/24 leads 24 22 79N-432-CXDB-00 4/4X/7/9 - IP 65 /2 Conduit w/24 leads 24 Notes. DIN connectors are ordered separately; see options section on page 6. 2. Explosion Proof valves MUST have voltage specified on order. 3. Interface blocks are available to convert 79N solenoids to pipe-mounted solenoids. 7

79L Keystone Mounting (Four-Way and Three-Way Two Position) 4/2 and 3/2 solenoid valves with interface according to Keystone Standard for use with double or single acting Keystone pneumatic rack and pinion actuators Figures 790/79U/79E/79D. Used to give twoposition operation with failure position on loss of power. 4/2 or 3/2 function available NEMA 4/4X or NEMA 4/4X/7/9 Manual override Continuous duty Air supply: filtered, lubed or non-lubed Remote mounting via sub base NBR Seals Model Numbers and Ordering Information Model NEMA Solenoid Voltage Number Rating Connection AC AC DC 60HZ 50HZ Type LP, Three-Way 79L-3-C4AA-00 4 /2 Conduit 0 0 60 79L-3-C4AB-00 4 /2 Conduit 245 220 79L-3-C4DA-00 4 /2 Conduit 24 22 79L-3-C4DB-00 4 /2 Conduit 24 79L-3-CXAA-00 4, 7, & 9 /2 Conduit 0 79L-3-CXAB-00 4, 7, & 9 /2 Conduit 245 79L-3-CXDA-00 4, 7, & 9 /2 Conduit 79L-3-CXDB-00 4, 7, & 9 /2 Conduit 24 Type LP, Four-Way 79L-4-C4AA-00 4 /2 Conduit 0 0 60 79L-4-C4AB-00 4 /2 Conduit 245 220 79L-4-C4DA-00 4 /2 Conduit 24 22 79L-4-C4DB-00 4 /2 Conduit 24 79L-4-D4AA-00 4X DIN Connection 0 0 60 79L-4-D4AB-00 4X DIN Connection 245 220 79L-4-D4DA-00 4X DIN Connection 24 22 79L-4-D4DB-00 4X DIN Connection 24 79L-4-CXAA-00 4, 7, & 9 /2 Conduit 0 79L-4-CXAB-00 4, 7, & 9 /2 Conduit 245 79L-4-CXDA-00 4, 7, & 9 /2 Conduit 79L-4-CXDB-00 4, 7, & 9 /2 Conduit 24 Notes. DIN Connectors must be ordered with DIN Solenoid Coils. 2. Explosion Proof Valves MUST have voltage specified on order. 3. Interface blocks are available to convert 79L solenoids to pipe mounted solenoids. 8

79L Keystone Mounting (Four-Way and Three-Way Two Position) 79L Four-Way NEMA 4, Conduit Connection Extended Turn Locking Override 0V/60HZ/6.0 WATTS 0V/50HZ/6.0 WATTS 60V DC/7.0 WATTS PSI: 50 MAXIMUM ORIF: 3/64 X /6 CODE: QE.65 2 4 4 5. /4 Inlet Port 3 5 79L Four-Way Flow Diagram 4 5 3 0.56 0.56.44 0.36 0.70.00 /8 Exh Ports Typical /2 Conduit 24 Lead Wire 0.33 2.00 3 /64 Dia. Mtg. Holes 0.67.34.27 79L Four-Way NEMA 4, 7, and 9.65 /2 Conduit 24 Lead Wire /4 Inlet Port 5.89 0.56 0.56.44 0.36 0.70.00 /8 Exh Ports Typical 0.33 2.00 3 /64 Dia. Mtg. Holes 0.67.34.27 9

79L Keystone Mounting (Four-Way and Three-Way Two Position) 79L Three-Way NEMA 4, Conduit Connection Extended Turn Locking Override 0V/60HZ/6.0 WATTS 0V/50HZ/6.0 WATTS 60V DC/7.0 WATTS PSI: 50 MAXIMUM ORIF: 3/64 X /6 CODE: QE.65 0 2 5. 4 3 0.36 0.70 3 /4 Inlet Port /2 Conduit 24 Lead Wire 0.56.44 /8 Exh Ports Typical 79L Three-Way Flow Schematic 2.00 0.67.34 3 /64 Dia. Mtg. Holes 79L Three-Way NEMA 4, 7, and 9 Push Non-Locking Override.65 /2 Conduit 24 Lead Wire /4 Inlet Port 4 3 0.36 0.70 5.89 0.29 0.56.44 2.00 /8 Exh Ports Typical 0.67.34.27 3 /64 Dia. Mtg. Holes 0

79P-Series Line Mounted (Four-Way Two Position) 4/2 and 3/2 way solenoid valve with all ports /4 NPT for use with Morin and Biffi actuators or any remote mounting application. 4/2 or 3/2 way function by plugging ports. Exhaust air can be throttled thus actuator speed can be extended (exhaust throttle option) Manual override Continuous duty Air supply: filtered, lubed or non-lubed NBR Seals Manual Override Push Non-Locking 0.50 4 4 Explosion Proof version shown 0.7 Dia. Mtg. Holes 0 2 0.97 0.64.94 0.64 3 Three-Way Schematic Symbol 0.43 0.43 24 Lead Wire 2 4 3 5 4.00 0.50 3 5 0.90 0.88 0.88 6.50 2.02 Four-Way Schematic Symbol Voltages available: Protection class: Connector: Ambient temperature: Air connection: Air pressure: Rated C v :.8 0/60 0/50 V AC 245/60 220/50 VAC 24/60 22/50, 24, 0 VDC NEMA 4/4X or NEMA 4/4X/7/9 /2 Conduit or DIN Connection -20 F up to +80 F [-30 C up to +82 C] /4 NPT Pressure Port 50 psig

79P-Series Line Mounted (Four-Way Two Position) Model Numbers and Ordering Information Model NEMA Solenoid Voltage Number Rating Connection AC AC DC 60HZ 50HZ Four-Way, DIN Connection, Single Solenoid Spring Offset 79P-4-D4AA-00 4/4X - IP 65 According to DIN 43650 form A 0 0 79P-4-D4AB-00 4/4X - IP 65 According to DIN 43650 form A 245 220 0 79P-4-D4DA-00 4/4X - IP 65 According to DIN 43650 form A 24 22 79P-4-D4DB-00 4/4X - IP 65 According to DIN 43650 form A 24 Four-Way, Conduit Connection (DIN Style Solenoid), Single Solenoid Spring Offset 79P-4-D4AA-0 4/4X - IP 65 /2 Conduit w/30 leads 0 0 79P-4-D4AB-0 4/4X - IP 65 /2 Conduit w/30 leads 245 220 0 79P-4-D4DA-0 4/4X - IP 65 /2 Conduit w/30 leads 24 22 79P-4-D4DB-0 4/4X - IP 65 /2 Conduit w/30 leads 24 Four-Way, Conduit Connection (Steel Housing), Single Solenoid Spring Offset 79P-4-C4AA-00 4/4X - IP 65 /2 Conduit w/24 leads 0 0 79P-4-C4AB-00 4/4X - IP 65 /2 Conduit w/24 leads 245 220 0 79P-4-C4DA-00 4/4X - IP 65 /2 Conduit w/24 leads 24 22 79P-4-C4DB-00 4/4X - IP 65 /2 Conduit w/24 leads 24 Four-Way, Explosion Proof, Conduit Connection, Single Solenoid Spring Offset 2 79P-4-CXAA-00 4/4X/7/9 - IP 65 /2 Conduit w/24 leads 0 0 79P-4-CXAB-00 4/4X/7/9 - IP 65 /2 Conduit w/24 leads 245 220 0 79P-4-CXDA-00 4/4X/7/9 - IP 65 /2 Conduit w/24 leads 24 22 79P-4-CXDB-00 4/4X/7/9 - IP 65 /2 Conduit w/24 leads 24 Notes. DIN connectors are ordered separately; see options section on page 6. 2. Explosion Proof valves MUST have voltage specified on order.

79P-Series Line Mounted (Four-Way Three Position) 4-way 3-position solenoid valve with all ports blocked when no power to either solenoid. Connections are /4 NPT for use with Morin, Biffi actuators or any remote mounting application. 4/3 or 3/3 way function by plugging ports Exhaust air can be throttled thus actuator speed can be extended (exhaust throttle option) Manual override Continuous duty Air supply: filtered, lubed or non-lubed NBR Seals Manual Override Push Non-Locking 0.50-4 -2 42 24 Lead Wire Explosion Proof version shown 0.7 Dia. 0.64 0.64.94 0.43 0.43 2 4 4 0.88 0.88 3 Four-Way, three position, blocked center schematic symbol 5.00 0.50 3 5 0.09 4.60 4.60 2.02 Voltages available: Protection class: Connector: Ambient temperature: Air connection: Air pressure: Rated C v :.8 0/60 0/50 V AC 245/60 220/50 VAC 24/60 22/50, 24, 0 VDC NEMA 4/4X or NEMA 4/4X/7/9 /2 Conduit or DIN Connection -20 F up to +80 F [-30 C up to +82 C] /4 NPT Pressure Port 50 psig 3

79P-Series Line Mounted (Four-Way Three Position) Model Numbers and Ordering Information Model NEMA Solenoid Voltage Number Rating Connection AC AC DC 60HZ 50HZ Four-Way, DIN Connection, Dual Solenoid Spring, Centered - Blocked Center 79P-432-D4AA-00 4/4X - IP 65 According to DIN 43650 form A 0 0 79P-432-D4AB-00 4/4X - IP 65 According to DIN 43650 form A 245 220 0 79P-432-D4DA-00 4/4X - IP 65 According to DIN 43650 form A 24 22 79P-432-D4DB-00 4/4X - IP 65 According to DIN 43650 form A 24 Four-Way, Conduit Connection (DIN Style Solenoid), Dual Solenoid Spring, Centered - Blocked Center 79P-432-D4AA-0 4/4X - IP 65 /2 Conduit w/30 leads 0 0 79P-432-D4AB-0 4/4X - IP 65 /2 Conduit w/30 leads 245 220 0 79P-432-D4DA-0 4/4X - IP 65 /2 Conduit w/30 leads 24 22 79P-432-D4DB-0 4/4X - IP 65 /2 Conduit w/30 leads 24 Four-Way, Conduit Connection (Steel Housing), Dual Solenoid Spring, Centered - Blocked Center 79P-432-C4AA-00 4/4X - IP 65 /2 Conduit w/24 leads 0 0 79P-432-C4AB-00 4/4X - IP 65 /2 Conduit w/24 leads 245 220 0 79P-432-C4DA-00 4/4X - IP 65 /2 Conduit w/24 leads 24 22 79P-432-C4DB-00 4/4X - IP 65 /2 Conduit w/24 leads 24 Four-Way, Explosion Proof, Conduit Connection, Dual Solenoid Spring, Centered - Blocked Center 2 79P-432-CXAA-00 4/4X/7/9 - IP 65 /2 Conduit w/24 leads 0 0 79P-432-CXAB-00 4/4X/7/9 - IP 65 /2 Conduit w/24 leads 245 220 0 79P-432-CXDA-00 4/4X/7/9 - IP 65 /2 Conduit w/24 leads 24 22 79P-432-CXDB-00 4/4X/7/9 - IP 65 /2 Conduit w/24 leads 24 Notes. DIN connectors are ordered separately; see options section on page 6. 2. Explosion Proof valves MUST have voltage specified on order. 4

Valves with interface according to NAMUR or Line Mounting for use with Tyco and Morin pneumatic rack & pinion or Morin and Biffi scotch yoke actuators. Used to give two position operation with failure position on loss of remote pneumatic signal or three position with lock up. 4/2 and 4/3 function available Continuous duty Air supply: filtered, lubed or non-lubed Remote mounting via sub base NBR Seals Directional Control Valves 79N and 79P Remote Air Pilot Keystone Mount.65.00 4 4.30 5 3 Plug Placed Here for 5/2 Operation (2) #0-32 Screws X.25 Long 0.50 /8 NPTF Port 2 4 4 3 5 Single Air Pilot Spring Return.26 0.88 0.88 0.22 Dia. Mtg Hole 0.94 Plug Placed Here for 3/2 Operation 0.63 2 4 4 0.47 Model Numbers and Ordering Information 0.22 Diax. X 0.3 Deep Locating Hole 3 5 NAMUR Mount, Single Air Pilot NAMUR Mount, Double Air Pilot Inline, Single Air Pilot Inline, Double Air Pilot 79N-452-A-00 79N-452-AA-00 79P-452-A-00 79P-452-AA-00 Dual Air Pilot Spring Centered - All Ports Blocked Dimensions, inches [mm] Single Air Pilot Dual Air Pilot A C F F G G H L L2 W 22.2.7 32.0 6.0 23.9.9 25.4 09 4.9 [0.88] [0.50] [.26] [0.63] [0.94] [0.47] [.00] [4.30] [.65] 22.2.7 32.0 6.0 23.9.9 25.4 2 4.9 [0.88] [0.50] [.26] [0.63] [0.94] [0.47] [.00] [4.80] [.65] 79P Single Air Pilot Spring Ambient temperature: Air connection: -20 F up to +50 F [-30 C up to +66 C] /4 NPT Pressure Port /4 Exhaust Port /8 Remote Signal Port Air pressure: 35 psig up to 50 psig Remote pressure signal: 35 psig up to 50 psig Rated C v : Single Air Pilot.8 Dual Air Pilot Spring Centered.4 5

Directional Control Valve 79L Remote Air Pilot Keystone Mount 4/2 valves with interface according to Keystone Standard for use with double acting Keystone pneumatic rack and pinion actuators Figures 790/79U/79E/79D. Used to give twoposition operation with failure position on loss of remote pneumatic signal. 4/2 function available Continuous duty Air supply: filtered, lubed or non-lubed Remote mounting via sub base NBR Seals.65 /8 NPTF Pilot Port 79L Remote Air Pilot 3.23 /4 Inlet Port 4 5 2.00 3 0.36 0.70.00 2 4 4 /8 Exh Ports Typical 0.56 0.56.44 3 5 2.00 Four-Way Air Pilot Schematic 0.67.34 3 /64 Dia. Mtg. Holes Ambient temperature: -20 F up to +50 F [-30 C up to +66 C] Air connection: /4 NPT Pressure Port /8 Exhaust Port /8 Remote Signal Port Air pressure: 35 psig up to 50 psig Remote pressure signal: 35 psig up to 50 psig Rated C v : 0.7 Model Number Keystone Mount Single Air Pilot: 79L-452-A-00 6

Rotator Plate For use with 790-600/700 or 79U-80/8 Solenoid Mounting (allows horizontal installation of directional control valve).65 0.50.75 Product Number: 79-KRPK Coil Technical Data Description and Outline Coil Style Code NEMX 4X with DIN 43650 Connection D NEMA 4X Steel Housing with molded coil, /2 conduit and 30 leads C Explosion-Proof /2 Conduit with 24 leads. NEMA 4,4X, 7C, 7D, 9E, 9F and 9G. UL: Class I, Div. 2 Groups A and B; Class I, Div., Groups C and D; Class II, Div., Groups E, F, and G; Temp Code T3C (60 C) X Note: Type D DIN coils must be ordered with appropriate DIN connectors (below). 7

DIN Connectors Voltage Voltage Current (Amps) Resistance Power (Watts) +0% Code Inrush Holding (Ohms @ 20 C) D C X D C X D C X D C X 22/50 24/60 0/50 0/60 220/50 240/60 DA 0.40 0.55 0.55 0.40 0.33 0.32 3 9 9 4.8 6 6 AA 0.087 0.3 0.3 0.06 0.06 0.06 840 475 475 4.8 6 6 AB 0.04 0.05 0.05 0.03 0.03 0.03 3400 2000 2000 6.0 6 6 VDC DA 0.40 0.60 0.60 0.40 0.60 0.60 3 9 29 4.8 7 7 24 VDC DB 0.20 0.30 0.30 0.20 0.30 0.30 75 75 4.8 7 7 5 VDC AB - - 0.04 0.06 0.06 3400 9 9 4.8 7 7.33 Ref Nitrile Gasket Strain Relief Cord. Unit has grommet style wiring support/seal with internal terminals for connection. No cord is supplied. Product No.: 79-DINCONG Conduit connection. Unit has /2 conduit entry for wiring with internal terminals for connection. No cord is supplied. Product No.: 79-DINCONC Molded connector with 6 foot cord. Unit has cord molded into connector. Product No.: 79-DINCONF Coils, Operator Cartridges, and Valve Operators Coil for DIN Connection Operator DIN Connection Valve Operator Valve Operator for NEMA 4 Steel Conduit Housing Valve Operator for NEMA 4/7/9 Steel Conduit Housing (optional locking override shown) 8

Accessories Speed Control Valves for AVID Controls Compact module with Keystone and NAMUR mounting O-ring seal for air passages Long taper needle for close control Speed Control Module mounts between Directional Control Valve (or adapter plate) and actuator. Mounts on NAMUR pad or Keystone pad. Functions as a flow control for both cylinder ports..4 Easily adjustable, turn needles clockwise to decrease speed and counterclockwise to increase speed. Normal operating pressure: 35 to 50 psig (2 to 0 barg).69 2.50 Normal operating temperature: -20 F to +5 F [-30 C to +52 C] Approximate weight: 2.5 oz [70.8 g] 2 4 Product Number Keystone Mounting NAMUR Mounting 79-KSCB 79-NSCB Schematic 79-PSC Exhaust Restrictor/Sintered Muffler Reduces exhaust noise level in air systems. Allows adjustment of exhaust air flow to accurately cocntrol cylinder speeds. Corrosion resistant. Cleanable 40 micron filter element. Part Pipe C v (l/min) Gr. (Oz.) Hex Size Length Number Size mm [in] mm [in] 79-PSC /8.20 [070] 29 [.0].7 [ /2] 39.3 [.55] 79-PSC2 /4.30 [60] 40 [.4] 4.3 [ 9 /6] 47.2 [.86] 79-PSC3 3/8 2.00 [790] 64 [2.3] 7.5 [ /6] 48.0 [.89] 79-PSC5 /2 3.70 [330] 4 [4.0] 22.2 [ 7 /8] 59. [2.33] 79-PSC7 3/4 5.90 [5270] 90 [6.7] 27.0 [ /6] 7.8 [2.83] 79-PSC0 6.80 [6000] 36 [.] 33.3 [ 5 /6] 76.2 [3.00] 9

Accessories Quick Exhaust, Check and Shuttle Valves One model does all three functions. Rugged internal construction outlasts and out-performs competition. Quick Exhaust Valve: When IN is pressurized, flow is from IN to OUT with EXH blocked. When OUT is pressurized, flow is from OUT to EXH with IN blocked. Check Valve: Free flow from IN to OUT with EXH plugged. No flow from OUT to IN with EXH plugged. Shuttle Valve: When IN is pressurized, flow is from IN to OUT with EXH blocked. When EXH is pressurized, flow is from EXH to OUT with IN blocked. Port Size Pressure Series NPTF Cv psig [bar] Model Lb. IN, OUT EXH [/min] Min Max Number (Kg) 79Q- 0-32 0-32 0. [00] 3 [0.2] 5 [8.5] 370A- 0.0 (0.02) 79Q-2 /8 /4 0.8 [790] 4 [0.3] 50 [0.7] 370A-2 0.08 (0.7) 79Q-22 /4 /4 0.9 [890] 4 [0.3] 50 [0.7] 370A-22 0.07 (0.6) 79Q-32 /4 3/8.9 [870] 3 [0.2] 50 [0.7] 370A-32 0.4 (0.3) 79Q-33 3/8 3/8 2.2 [260] 2 [0.] 50 [0.7] 370A-33 0.4 (0.3) 79Q-75 /2 3/4 2.6 [2560] [0.] 50 [0.7] 370A-75 0.45 (0.99) 79Q-77 3/4 3/4 2.9 [2850] [0.] 50 [0.7] 370A-77 0.4 (0.94) Quick Exhaust EXH IN D OUT E Check A B C EXH IN EXH Plugged Dimensions, inches [mm] EXH (IN) Shuttle OUT IN Model Number A B C D E 79Q-2.09 [27.7] 0.55 [3.9] 0.8 [20.5].22 [30.3].67 [42.4] 79Q-32 79Q-33.50 [38.] 0.83 [2.].25 [3.8].78 [45.2] 2.38 [50.4] 79Q-75 79Q-77 2.6 [55.4].4 [28.9].6 [45.9] 2.78 [70.5] 3.66 [92.9] Tyco Valves & Controls www.tycovalves.com Tyco Flow Control (TFC) provides the information herein in good faith but makes no representation as to its comprehensiveness or accuracy. This data sheet is intended only as a guide to TFC products and services. Individuals using this data sheet must exercise their independent judgment in evaluating product selection and determining product appropriateness for their particular purpose and system requirements. TFC MAKES NO REPRESENTATIONS OR WARRANTIES, EITHER EXPRESS OR IMPLIED, INCLUDING WITHOUT LIMITATION ANY WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE WITH RESPECT TO THE INFORMATION SET FORTH HEREIN OR THE PRODUCT(S) TO WHICH THE INFORMATION REFERS. ACCORDINGLY, TFC WILL NOT BE RESPONSIBLE FOR DAMAGES (OF ANY KIND OR NATURE, INCLUDING INCIDENTAL, INDIRECT, OR CONSEQUENTIAL DAMAGES) RESULTING FROM THE USE OF OR RELIANCE UPON THIS INFORMATION. Patents and Patents Pending in the U.S. and foreign countries. Tyco reserves the right to change product designs and specifications without notice. 20