Steam Trap Test Station

Similar documents
Multipurpose Ball Valves

Proportional Relief Valves

Stainless Steel Valves For the Sanitary Industries

Compact, High-Flow Gas Regulators

Severe-Ser vice Union-Bonnet Needle Valves

Severe-Service Union-Bonnet Needle Valves

TY-FLO Needle Valves

Stream Selector System

Float and Thermostatic Traps Series H, C and X

ball valves Flomite 71 Series 2-way Integral Panel Mount Ball Valves

Variable Area Flowmeters

STEAM AND CONDENSATE PIPING AND PUMPS DESIGN AND CONSTRUCTION STANDARD PART 1: GENERAL Purpose:

Ball Valves (HB Series) Catalog 4121-HB Revised, April 2005

Regulator Options and Accessories

Shut-off & Lockout Valves 1/4" to 1-1/2" port size

TYPE E Main Valve Sizes 3 /8 through 12

API Flanged Safety Relief Valves Series 526 CATALOG

Installation and Operating Instructions Installation Instructions for SS EPE-316L Series

Pipe threads for tubes and fittings where pressure-tight joints are not made on the threads. (requires PTFE sealing tape or liquid sealant).

Integral-Bonnet Needle Valves

PRESSURE REDUCING CONTROL VALVE

Mustang Series PRESSURE REDUCING CONTROL VALVE WITH PRESSURE SUSTAINING FEATURE. M115-2 (Globe) M (Angle) Schematic. Standard Components

DARTMOUTH COLLEGE DESIGN January 3, 2012 & CONSTRUCTION GUIDELINES

AIR LINE VALVES AND GAUGES

Spira-trol TM Two-port Control Valves EN Standard KE, KF and KL DN15 to DN300 and ASME Standard KEA, KFA and KLA ½" to 12"

S GATE KNIFE GATE VALVE WITH PNEUMATIC ACTUATOR

Fisher 1052 Size 20 Diaphragm Rotary Actuator with F and G Mounting Adaptation

James M. Pleasants Company

FLASH TANK ECONOMIZER PRODUCT GUIDE

Style 07 Zero Flex Rigid Coupling. Style 75 Flexible Coupling. Style 77 Flexible Coupling 11. Description

Submersion/Insertion Toroidal Sensor

VALVES FOR REFRIGERATING SYSTEMS

Stainless Steel Single and Dual Circulation Kits

VAD. Variable Area Desuperheaters

Valves, Automation & Controls. series 84 /99 HIGH PERFORMANCE 3-PIECE BALL VALVE REDUCE & FULL PORT, STANDARD & FIRE SAFE.

Baumann Flexsleev Sanitary Control Valve

WD600 STEAM TRAPS. Thermodynamic Steam Trap

Toroidal Conductivity Sensor

ABV20 Air Actuated Boiler Blowdown Valve Installation and Maintenance Instructions

CRANE. Σελίδα 1 από 2. Dimensions and Weights. Weight (kg) Size

IF IT FLOWS THE BOWIE PUMP CAN PUMP IT

TECHNICAL DATA. Dry 122a. November 12, 2013

Non-Code Liquid Relief, ASME Section VIII, Air/Gas and Steam, National Board Certified, Safety and Relief Valves

DESIGN STANDARDS SECTION

REGULATORS D& HD Series

TAMPERS Tabor Place, Santa Fe Springs, California, CA 90670, U.S.A.

Ve-Lock manufactures Needle Valves from Solid bar stock Materials & all parts details are as below:

300 SERIES 331, 332, 333, 344, 356 AND 367 MODELS

VAD Variable Area Desuperheaters

Block and Bleed Gauge Valves M25 and M251

USER MANUAL. 10 GPM Small Single Line Cryogenic Coupling

FUEL SYSTEMS OUR PARTS PUT YOU IN THE PASSING LANE. Protect your fuel system. velvac.com

Baumann Little Scotty Bronze Control Valve

Baumann Way Bronze or Stainless Steel Control Valve

ISORIA. Centered disc butterfly valves with AMRING elastomer liner. 240 PSI: 1½ to PSI : 10 to 24

Constantemp Double Wall Low pressure steam-water Heater F-340LDW,F-640LDW, F-940LDW and F-1240LDW

3", 4", 6" & 8" Model H Series Alarm Check Valve Installation and Maintenance Guide

Thread and End Connection

Installation, Operation and Maintenance Manual for Pilot Operated Valves

HM Series - DBB. Single, Double Block & Bleed Valves. Continuously Improving Flow Control

CHEXTER TM FITS YOUR APPLICATION, PROFITABLY

Pilot Operated Pressure Reducing Valve PRV 47 (Steel) PRV47I (St.Steel)

MADE IN THE USA BALL VA LV ES

QLM and QLD Series Three-port Control Valves

REGULATORS 175/153 Series

MVX-Series Diesel Engine Air Shut Down Valves

CHIPPING HAMMERS Tabor Place, Santa Fe Springs, California, CA 90670, U.S.A.

KEYSTONE. Stainless steel hygienic butterfly valves F250 for imperial tubing F251 for metric tubing

needle valves Needle Valves Index At a Glance 1

STORAGE, INSTALLATION AND MAINTENANCE PROCEDURES

OPERATING and MAINTENANCE MANUAL SERIES 2700A CONTROL VALVE CONTENTS. INTRODUCTION...1 Scope...1 Description...1 Valve Identification...

Model RV-1 Pressure Relief Valve 2 to 8 Inch (DN50 to DN200), 250 psi (17,2 bar) Pilot-Operated, Globe and Angle Body Styles General Description

RUBBER SLEEVE KNIFE GATE VALVE

VCR Metal Gasket Face Seal Fittings

MTI10 Insertion and MTL10 In-line Thermal Mass Flowmeter and Temperature Transmitter

Replacement parts. WM97+ gas-fired water boiler Boiler Manual. OBTAIN PARTS ONLY THROUGH WEIL-McLAIN THE BOILER CONTAINS CERAMIC FIBER MATERIALS

Fire Hydrant Troubleshooting

SIMPLAIR PIPING TOOL

THERMOSTATIC MIXING VALVE TRIM K-T9493, K-T9494

MFP14, MFP14S and MFP14SS Automatic Pumps

BERMAD Fire Protection

Copper Meter Resetters

Seated valves (PN 16) VF 2 2-way valve, flange VF 3 3-way valve, flange

TB2CS Conductivity sensor 2-Electrode. Superior accuracy in low level conductivity measurement ranges

ASME/ANSI B Cast Iron Pipe Flanges and Flanged Fittings ASME/ANSI B Malleable Iron Threaded Fittings ASME/ANSI B16.

APCO SLOW CLOSING AIR/VACUUM VALVES

Blowdown vessels Meeting the requirements of HSE PM60

Morrison Bros. Co. General Product Specifications

2 H OW TO ORDER 2 D ESIGN FEATURES 3 P RODUCTS INDEX 35 O VAL FLANGES 35 B LEED 35 C ONDENSING POTS 36 S YPHONS 36 A IR FEED HEADERS

Fig B36 Stainless Steel 'T' Type or Basket Type Strainers

167D Series Switching Valves

Baumann Mikroseal Control Valve

Multijacketed Tubing, Single-Jacketed Tubing, and Insulated Tubing

Product Manual. CVS Type 67AFR Filter Regulator. Introduction. Installation. Description

1805 Series Relief Valves

Vogt Valves The Connection Bulletin for Extended Body Forged Steel Valves Welded Bonnet, Bolted Bonnet, Class 800 & Class 1500 CB 22

Pipe Valves, Fittings and Nipples Pressures to 15,200 psi

ROUGHNECK II Pumpless Drain

GAS DISTRIBUTION PRODUCTS STEEL SERVICE TEES

Type 119 Control Valve

Transcription:

www.swagelok.com Steam Trap Test Station With Universal Mount TVA Series Offers fast visual monitoring of steam trap performance Includes universal mount for steam trap Service rating: 250 psig (17.2 bar) at 417 F (213 C) 316 and 316L stainless steel materials Universal mount without test valves available separately Service rating: 600 psig (41.3 bar) at 750 F (400 C)

2 Steam Trap Test Station with Universal Mount Features Isolation valve with oval handle provides quick, quarter-turn shut off Universal mount allows quick, easy installation of a steam trap component Test valve allows visual monitoring of steam trap performance with quarter-turn operation Flow direction arrow Optional locking handle can lock valve open or closed accommodates shackle diameters smaller than 0.344 in. (8.7 mm) Strainer cap provides access to strainer element. Test valve vent shown facing down. See Ordering Information for other vent locations. Optional strainer cap with integral Swagelok tube adapter is available. See Ordering Information, Blowdown Options, for tube adapter sizes. Optional Swagelok tube adapter strainer cap allows direct mounting of a needle or ball valve for blowdown. Steam Trap Test Station Assembly consists of two stainless steel 63 series ball valves and a universal mount; two mounting bolts to mount steam trap are included. Steam trap is not included. Compact design reduces space requirements; flange of universal mount bolts directly to the ball valve body. Choice of left or right flow direction with a flow direction arrow on the universal mount. Universal Mount Two-bolt, universal design offers quick, easy installation of a steam trap. Cast body material is CF3M and includes an integral 20 mesh (840 µm) strainer. Optional strainer cap with integral Swagelok tube adapter allows direct mounting of blowdown valve. See page 5 for more information on the universal mount, including materials of construction. Isolation and Test Ball Valves Quarter-turn handles show valve open or closed position. Oval handle types include locking, nonlocking, and latchlocking. Locking handles enable compliance with OSHA Lockout/Tagout, Standard 29 CFR Part 1910.147 Control Of Hazardous Energy. Valve end connection options include Swagelok tube fittings (1/2 and 3/4 in., and 12 mm), female NPT (1/2 in.) and female ISO 7/1 (1/2 in.) Choice of test valve vent locations includes facing towards the steam trap, facing away from steam trap, and facing down. See the Swagelok Ball Valves, General Purpose and Special Application 60 Series catalog, MS 01 146, for stainless steel 63 series valve technical data, including materials of construction and other options.

Steam Trap Test Station Technical Data Pressure rating: 600 psig (41.3 bar) at 70 F (20 C) Temperature rating: 450 F (232 C) at 100 psig (6.8 bar) Service rating: 250 psig (17.2 bar) at 417 F (213 C) Valve seat and seal options can affect service ratings. Testing Every Swagelok steam trap test station assembly is factory tested with nitrogen at 1000 psig (69 bar) or its maximum working pressure if less than 1000 psig (69 bar). Seats have a maximum allowable leak rate of 0.1 std cm 3 /min, lower than allowable in FCI 70-2 Specification Class VI. Shell testing with nitrogen at 1000 psig (69 bar) or the maximum rated pressure if less than 1000 psig (69 bar) is performed to a requirement of no detectable leakage with a liquid leak detector. Steam Trap Test Station with Universal Mount 3 Cleaning and Packaging All Swagelok integrated test valve assemblies are cleaned in accordance with Swagelok Standard Cleaning and Packaging (SC-10), MS-06-62. Accessories To order the universal mount component separately, see page 6. Maintenance Kits For the valves, see the Swagelok Ball Valves, General Purpose and Special Application 60 Series catalog, MS 01 146. For the universal mount component, see page 6. Dimensions Dimensions, in inches (millimeters), are for reference only, and are subject to change. End Connection A Type Size in. (mm) 1/2 in. Swagelok 1.16 3/4 in. tube fitting (29.5) 12 mm Female NPT 1/2 in. 0.49 Female ISO 7/1 1/2 in. (12.4) Dimensions shown with Swagelok nuts fingertight, where applicable. See specifications ISO 7, BS 21, and JIS B0203. 3.94 (100) Latch-lock handles 2.95 (74.9) Locking (shown) and nonlocking handles 0.25 (6.4) 2.16 (54.9) A 7.07 (180) 2.83 (71.9)

4 Steam Trap Test Station with Universal Mount Steam Trap Test Station Ordering Information To create an ordering number, select designators in the sequence shown. SS - TV L 1 - T - S8 - H1 - SX -40 Material 316 stainless steel Series Test valve assembly Flow Direction (See below.) L = R = Blowdown Options 1 = Standard, no fitting 2 = 3/8 in. Swagelok tube adapter 3 = 1/2 in. Swagelok tube adapter 4 = 3/8 in. Swagelok 62 series ball valve with PTFE seat and locking lever handle➀ 5 = 3/8 in. Swagelok 1 series needle valve with vee stem and round handle➁ ➀ See the Swagelok Ball Valves, General Purpose and Special Application 60 Series catalog, MS 01 146, for technical data and materials. ➁ See the Swagelok Integral-Bonnet Needle Valves O, 1, 18, 20, and 26 Series catalog, MS 01 164, for technical data and materials. Packing/Seat Material Reinforced PTFE Flow Direction: (Outlet on the right) Flow Direction Options Flow Direction: (Outlet on the left) Blowdown Strainer None = Standard, 20 mesh (840 µm) -40 = 40 mesh (400 µm) Test Valve Vent Location None = No vent port SX = Toward trap XP = Away from trap XB = Downward Oval Handles Isolation Valve / Test Valve H1 = Locking / locking H2 = Locking / nonlocking H3 = Latch-lock / latch-lock H4 = Latch-lock / nonlocking H5 = Nonlocking / nonlocking End Connection Size and Style (Same inlet and outlet) S8 = 1/2 in. Swagelok tube fitting S12 = 3/4 in. Swagelok tube fitting S12MM = 12 mm Swagelok tube fitting F8 = 1/2 in. female NPT F8RT = 1/2 in. female ISO 7/1 To specify different inlet and outlet end connections, insert a designator for the inlet connection followed by a designator for the outlet connection. Example: SS-TVL1-T-S8F8-H1-SX See the Swagelok Ball Valves, General Purpose and Special Application 60 Series catalog, MS 01 146, for additional stainless steel 63 series valve end connection options. Swagelok Custom Solutions Although a variety of steam trap test station assemblies are available as standard, there may be those applications which require different components or configurations. If a custom solution is required, Swagelok welcomes these requests.

Steam Trap Test Station with Universal Mount 5 Universal Mount Features Two-bolt universal mount offers quick, easy installation of a steam trap Swagelok tube fitting end connections for tubing systems (1/2 and 3/4 in., and 12 mm) Female pipe thread end connections for piping systems (1/2 and 3/4 in. NPT and ISO tapered) Integral 20-mesh (840 µm) strainer Carbon steel mounting bolts (3/8-16 threads) included Choice of left or right flow direction options Front CF3M body with integral strainer Flow direction arrow Back Flow Direction: (Outlet on the right) Flow Direction: (Outlet on the left) Two-bolt, flush pattern universal mount Technical Data Maximum pressure rating: 600 psig (41.3 bar) Maximum temperature rating: 750 F (400 C) Service rating: 600 psig (41.3 bar) at 750 F (400 C) Materials of Construction 5 1 2 Component Wetted components listed in italics. Material Grade/ ASTM Specification 1 Body CF3M/A351 2 Strainer element 316 SS/A240 with silver solder 3 Strainer gasket Silver-plated 316 SS/A240 4 Strainer cap 316 SS A479 5 Bolts Grade B7 carbon steel/a193 Lubricants Fluorinated-based and molybdenum disulfide-based 3 Optional integral Swagelok tube adapter strainer cap 4 Testing Every Swagelok universal mount is factory shell tested with nitrogen at 600 psig (41.3 bar) using a liquid leak detector with a requirement of no detectable leakage. Cleaning and Packaging All Swagelok universal mounts are cleaned in accordance with Swagelok Standard Cleaning and Packaging (SC-10), MS 06 62.

6 Steam Trap Test Station with Universal Mount Universal Mount Ordering Information and Dimensions Select an ordering number. End Connection Type Size Swagelok tube fitting Female NPT Female ISO 7/1 1/2 in. 3/4 in. 12 mm 1/2 in. 3/4 in. 1/2 in. 3/4 in. Flow Direction Ordering Number SS-MB-UM-S8-R SS-MB-UM-S8-L SS-MB-UM-S12-R SS-MB-UM-S12-L SS-MB-UM-S12MM-R SS-MB-UM-S12MM-L SS-MB-UM-F8-R SS-MB-UM-F8-L SS-MB-UM-F12-R SS-MB-UM-F12-L SS-MB-UM-F8RT-R SS-MB-UM-F8RT-L SS-MB-UM-F12RT-R SS-MB-UM-F12RT-L Dimensions, in inches (millimeters), are for reference only and are subject to change. 4.36 (111) 1.88 (47.8) 0.94 (23.9) Options Swagelok Tube Adapter Strainer Cap To order a universal mount with factory-assembled integral Swagelok tube adapter strainer cap, add a blowdown strainer cap designator to the universal mount ordering number. Example: SS-MB-UM-S8-R2 Strainer cap kits for field assembly are available. The kits contain an integral tube adapter strainer cap, strainer gasket, and instructions. Select a kit ordering number. Tube Adapter Size Maintenance Kits Bolt and Strainer Kit Kit includes two mounting bolts, a strainer, a strainer gasket, and instructions. Kit ordering number: SS-3K-UM-4F Strainer Gasket Kit Kit includes a strainer gasket and instructions. Kit ordering number: SS-UM-K3 Blowdown Strainer Cap Designator 3/8 in. 2 1/2 in. 3 Tube Adapter Size Kit Ordering Number 3/8 in. SS-UM-TA6 1/2 in. SS-UM-TA8 2.00 (50.8) bolt circle 3.48 (88.4) 2.16 (54.9) Swagelok Tube Fitting Ends Dimensions shown with Swagelok tube fitting nuts finger-tight. 3.58 (90.9) Female Pipe (NPT and ISO) Ends

Steam Trap Test Station with Universal Mount 7

Safe Product Selection When selecting a product, the total system design must be considered to ensure safe, trouble-free performance. Function, material compatibility, adequate ratings, proper installation, operation, and maintenance are the responsibilities of the system designer and user. Warranty Information Swagelok products are backed by The Swagelok Limited Lifetime Warranty. For a copy, visit swagelok.com or contact your authorized Swagelok representative. Caution: Do not mix or interchange parts with those of other manufacturers. Swagelok TM Swagelok Company 2004 2012 Swagelok Company Printed in U.S.A., AGS MS-02-221, R3