Variable Frequency Drive / Inverter (0.4 ~ 280kW)

Similar documents
Easy to connect - Easy to configure Easy to install

Frequency Converter Fv

STARVERT ig5a. Compact & Powerful Inverter. 0.4~7.5kW 3Phase 200~230Volts 0.4~7.5kW 3Phase 380~480Volts. Automation Equipment

MC Series Drives. Flexible, simple, rugged, robust! Phone: Fax: Web: info@actechdrives.

MSN 70. Streç Film & Alüminyum Folyo Sarým Makinesi. Kullanma Kýlavuzu. Mertsan. Makine San. Tic. Ltd.Þti.

SAFETY INSTRUCTIONS WARNING

32VFD Variable Frequency Drives for Centrifugal Chillers

WJ200 series Pursuing the Ideal Compact Inverter

Specifying a Variable Frequency Drive s

vacon x series rugged drives for the real world

Number 1 in efficiency

EFC Frequency converters

NX Series Inverters. HVAC Pocket Programming Guide

AC ADJUSTABLE SPEED DRIVES MICRO SERIES INVERTERS

SAFETY INSTRUCTIONS WARNING

The HVAC SOLUTION DELIVERING POWER...SAVING ENERGY

1 Application Description Objective Goals... 3

SAFETY INSTRUCTIONS. Always follow safety instructions to prevent accidents and potential hazards from occurring.

TABLE OF CONTENTS. Fig. 1 EV Pictorial Wiring Diagram 5. Section 2 Inverter Option Modules 6

2011 Industrial Catalog. DRIVES, PAC, PLCs. Industrial Catalog

SAFETY INSTRUCTIONS. Always follow safety instructions to prevent accidents and potential hazards from occurring.

A1000 Cheat Sheet (Open Loop Vector)

DC UPS. RTB.e A. IMB.e/ITB.e kva. E2001.e/E3001.e kva. Input voltage: 110/125/220 Vdc. 115/120/230 Vac, 1-phase (IMB.

High Torque Performance and Precise Control

How To Use The Vacon 0 Machinery

PowerFlex 525 AC Drive. The Next Generation of PowerFlex Compact Drives

ABB general machinery drives. User s manual ACS355 drives

Display Group Parameters

SAFETY INSTRUCTIONS. To prevent injury and property damage, follow these instructions during the installation and operation of the inverter.

Starvert ic5. Variable Frequency Drive / Inverter. Automation Equipment. Leader in Electrics & Automation

Configuring Allen-Brandly ControlLogix PLC with Moxa MGate 5105-MB-EIP. 1 Application Description Objective Goals...

ABB machinery drives. User s manual ACS355 drives

Principles of Adjustable Frequency Drives

VARIABLE FREQUENCY DRIVES Revised 4/30/ Mechanical Systems

TECHNICAL SPECIFICATIONS FOR 1.5 KVA ONLINE UPS

Ordering Part Numbers:

J1000. System configuration

SJ200 Series Inverter Quick Reference Guide

Reliance Electric GV3000/SE Industrial AC Drive

REGAL-BELOIT. Installation and Operation Manual. Variable Speed AC Motor Drives. Micro and PowerWash Series

Bulletin 150 SMC Flex Smart Motor Controller Specifications

Analog Servo Drive 25A8

Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs

PRODUCT LIST Facility DDC Access WebXL DDC

UPS PIco. to be used with. Raspberry Pi B+, A+, B, and A. HAT Compliant. Raspberry Pi is a trademark of the Raspberry Pi Foundation

... Electronic Softstarter...

NXL Series Inverters. HVAC Inverters made simple

Z1000 HVAC Drive. 3 HP to 500 HP Fan and Pump Applications. Specifications

GE Energy Industrial Solutions. New. AF-6 Series Drives. Built-in features Built-in simplicity. GE imagination at work

HVAC03C2 HVAC61C2 HVAC03C5 HVAC61C5 NXL HVAC INVERTERS

Additional Benefits of VFDs In addition to energy savings and better process control, VFDs can provide other benefits:

FlexPak 3000 Digital DC Drive Software Reference Manual Version 4.3

Electronics Ltd. Presenting. Power, Intelligence... with a sense of feeling

LG Air Conditioning Multi F(DX) Fault Codes Sheet. Multi Split Units

Speed Control Methods of Various Types of Speed Control Motors. Kazuya SHIRAHATA

VLT AutomationDrive for Marine winch applications

Technical Specifications: The specifications represent a particular hardware platform. Application-specific software is provided.

New micro size drive of LS Industrial Systems STARVERT


sip Sanyo Modbus Guide Technical Specification Pinouts, Cable Connections & Wiring Issue 2: February 2009 Synapsys Solutions Ltd, all rights reserved

SPEEDMASTER MICRO SERIES COMPACT INVERTERS

Install the DeviceNet Module using the following procedure:

Pulse Width Modulated (PWM)

SAFETY INSTRUCTIONS. Always follow safety instructions to prevent accidents and potential hazards from occurring.

Pulse Width Modulated (PWM) Drives. AC Drives Using PWM Techniques

LIFT CONTROL SYSTEMS CATALOGUE 2007

Disturbance Recoder SPCR 8C27. Product Guide

Data Acquisition Module with I2C interface «I2C-FLEXEL» User s Guide

AC Variable Speed Drive. Powerful Performance. Advanced motor control. 0.75kW 250kW / 1HP 350HP V Single & 3 Phase Input

LIFT CONTROL SYSTEMS CATALOGUE 2007

with Electronic Assistant

Sigma Control PC INSIDE. 97 psi 187 F R on load

TRAMS TROLLEY-BUSES SUBWAY

Installation manual. Generator Paralleling Controller GPC multi-line C

VS-606V7 Series Instruction Manual COMPACT GENERAL-PURPOSE INVERTER (VOLTAGE VECTOR CONTROL)

Sierra Dual 24 Volt Brushless DC Motor Controller Product Specification

ABB PSPS Erich Steinmann; Generator control-2013

Clean and compact drive for energy savings. Altivar 1100 Medium-voltage variable speed drive 0.3 to 10 MW. DIA2ED EN.indd 1 22/07/09 11:36:14

2.1 FOR Series 15i Servo Alarm TROUBLESHOOTING 2.ALARM NUMBERS AND BRIEF DESCRIPTIONS. Alarm No. SVM PSM Description Remarks

BT300 HVAC Drives Conventional Bypass (C-Bypass) Options

Starvert ih. Variable Frequency Drive / Inverter. Automation Equipment. Leader in Electrics & Automation

Winding Applications. Winding Applications. An overview to winder applications along with Mitsubishi Electric solutions

Application/Connection Examples

What Is Regeneration?

August SECO DC DRIVES. Table of Contents

MC1000 Series Installation and Operation Manual

User Manual. MODBUS-RTU Option Board for SV-iS5 Series. LG Industrial Systems

APPENDIX. SureSERVO QUICK START GUIDE. In This Appendix... Quick Start for SureServo Drives...A 2. Tuning Quick Start for SureServo Drives...

Product Description Primary Resistance Starting Electric Fire Pump Controllers FTA1500

SINUS M. USER MANUAL -Installation and Programming Instructions-

Phone: Fax: Web: info@clrwtr.com

Siemens Standard Drives. Application Handbook

Flexible Counter Series in DIN size 24 x 48 mm

UPiS - Uninterruptible Power intelligent Supply

Discover the power of e-learning! The Quick Guide to AC Variable Frequency

Digital and Analog I/O

CONSTRUCTION STANDARDS DIVISION 23 HEATING VENTILATING AND AIR CONDITIONING

/ Instruction Manual. Analog Input/Output Interface Card "OPC-G1-AIO"

An overview of Computerised Numeric Control (C.N.C.) and Programmable Logic Control (P.L.C.) in machine automation

Transformerless UPS systems and the 9900 By: John Steele, EIT Engineering Manager

Transcription:

Variable Frequency Drive / Inverter (0.4 ~ 280kW)

& Standard Features Configuration Comparison Comparison Table Enclosure IP00 IP20 NEMA 1 Rating Single phase 0.4 2.2kW 0.4 1.5kW Three phase 0.4 4kW Constant torque Variable torque Input voltage margin -10 +10% -10 +10% Carrier frequency 1 15kHz 1 10kHz Braking Torque without resistor 20% with resistor 150% Power Module IGBT Diode Module Braking IGBT PIM (Integrated type) Output Frequency 0 400Hz 0 400Hz Control method V/F Sensorless vector sensored vector Keypad Fixed Removable Operator control LCD keypad 4 digits 7-segment keypad 3 digits 7-segment keypad Built-in potentiometer PNP / NPN selectable signal Communication RS485 (built-in) Modbus-RTU built-in Profibus DP DeviceNet F-Net (LG) I/O extension 3 Sub-boards Encoder feedback Flexible I/O Software features Cooling fan On/Off control Auto-tuning PI control PID control Multi-motor control Analog input 0 10V -10 +10V 4 20 ma 0 20 ma Analog output 1 0 10V 2 0 10V 4 20 ma Remote option 2 meter LG cable 3 meter LG cable 5 meter LG cable Telephone cable Ambient temperature -10 40-10 40 ic5 ig5

RFI Filters is5 ih ic5 0.4 ~ 2.2kW ic5 0.4 ~ 4.0kW ig5 0.75 ~ 75kW is5 30 ~ 280kW ih Class A Built-in footprint standard footprint standard Class B Footprint* Standard* footprint standard footprint standard Standard 0.75 75kW 30 280kW -10 +10% -10 +10% 1 15kHz 2 10kHz 100% 150% built-in 7.5kW 0 400Hz 0 400Hz () () () Driveview Monitoring Software Versatile, easy-to-use software for LG Inverter Provides intuitive means for monitoring, control and commissioning of Inverter Runs on RS-232 / 485 serial network connection Designed for Microsoft Windows 95 or later Keypad emulator Graphic monitor Parameter editor Text monitor (5mm) (10mm) -10 40-10 40

ic5 Starvert ic5 Volts / hertz & sensorless vector control (PWM by IGBT) Motor parameter auto-tuning 150% torque at 0.5Hz 0 ~ 400Hz output frequency 1 ~ 10kHz carrier frequency Built-in process PID control Ground fault protection Built-in RFI filter (class A) Built-in potentiometer Programmable I / O PNP / NPN selectable signal input 0 ~ 10Vdc Analog output ModBus communication chip Dynamic & Micro Single Phase Inverter 0.4 ~ 2.2 kw, 1ф Specifications SV004iC5-1 SV008iC5-1 SV015iC5-1 SV022iC5-1 SV004iC5-1F SV008iC5-1F SV015iC5-1F SV022iC5-1F Motor rating [HP] 0.5 1 2 3 0.5 1 2 3 [kw] 0.4 0.75 1.5 2.2 0.4 0.75 1.5 2.2 Output ratings Capacity [kva] 0.95 1.9 3 4.5 0.95 1.9 3 4.5 FLA [A] 2.5 5 8 12 2.5 5 8 12 Voltage [V] Three phase, 200 230V Frequency [Hz] 0 400Hz Input ratings Voltage [V] Single phase, 200 230V (±10%) Frequency [Hz] 50 60Hz (±5%) Control method Sensorless Vector V/F Frequency setting resolution Digital reference: 0.01Hz Analog reference: 0.06Hz at 60Hz Frequency setting accuracy Digital: 0.01% of Maximum output frequency Analog: 0.1 % of Maximum output frequency V/F ratio Linear Square User V/F Overload capacity 1 minute at 150% 30 seconds at 200% (with inverse characteristic proportional to time) Torque boost Auto Manual RFI filter None Built-in (class A) Multi-function input terminals Total 5 inputs (programmable) Analog output 0 10V Linear Input signal Operator control 3 digits LED keypad Terminals ModBus communication(option) Frequency setting Analog: 0 10V, 4 20mA Digital: Keypad Communication: ModBus Potentiometer Start signal Forward Reverse Multi-step operation Setting up to 8 speeds (using multi-function terminal) Multi-step Accel./Decel. time 0.1 6000 seconds. Maximum 8 pre-defined steps using multi-function terminals Operational functions PID control Up-Down operation 3-wire operation Frequency limit Frequency jump Second motor function Slip compensation Reverse rotation prevention Auto restart Emergency stop Interrupting output from inverter Jog Jog operation Fault reset Reset fault signal when protective function is active Output signal Frequency detection Overload alarm Stall Overvoltage Undervoltage Inverter overheat Run Stop Operational status Constant speed Speed search Fault output (Relay output and Open collector output) Indicator Output frequency Output current Output voltage DC bus voltage Protective functions Trip Alarm Overvoltage Undervoltage Overcurrent Inverter overheat Motor overheat I/O phase loss I/O miss wiring Overload External device fault 1 & 2 Speed command loss Hardware fault Communication error CPU error Stall Overload

ig5 Starvert Space Vector Control technology Volts / hertz control (PWM by IGBT) 150% torque at 0.5Hz 1 ~ 10kHz carrier frequency Trip-free operation algorithm Auto & manual torque boost 8 preset speeds Built-in Process PID Built-in Braking IGBT Built-in ModBus / RS485 communication PNP / NPN selectable signal 4 digits detachable display (keypad) Parameter upload & download User Friendly Compact Inverter 0.4 ~ 4.0 kw, 3ф 0.4 ~ 1.5 kw, 1ф Specifications SV004iG5-1U SV008iG5-1U SV015iG5-1U SV004iG5-2U SV008iG5-2U SV015iG5-2U SV022iG5-2U SV037iG5-2U SV040iG5-2U Motor rating [HP] 0.5 1 2 0.5 1 2 3 5 5.4 [kw] 0.4 0.75 1.5 0.4 0.75 1.5 2.2 3.7 4 Output ratings Capacity [kva] 1.1 1.9 3 1.1 1.9 3 4.5 6.1 6.5 FLA [A] 3 5 8 3 5 8 12 16 17 Voltage [V] Three phase, 200 230V Three phase, 200 230V Frequency [Hz] 0 400Hz 0 400Hz Input ratings Voltage [V] Single phase, 200 230V (±10%) Three phase, 200 230V (±10%) Frequency [Hz] 50 60Hz (±5%) 50 60Hz (±5%) SV004iG5-4U SV008iG5-4U SV015iG5-4U SV022iG5-4U SV037iG5-4U SV040iG5-4U Motor rating [HP] 0.5 1 2 3 5 5.4 [kw] 0.4 0.75 1.5 2.2 3.7 4 Output ratings Capacity [kva] 1.1 1.9 3 4.5 6.1 6.5 FLA [A] 1.1 2.5 4 6 8 9 Voltage [V] Three phase, 380 460V Frequency [Hz] 0 400Hz Input ratings Voltage [V] Three phase, 380 460V (±10%) Frequency [Hz] 50 60Hz (±5%) Control method Frequency setting resolution Frequency setting accuracy V/F ratio Overload capacity Torque boost Assigned terminals Multi-function input terminals Analog output V/F Control (Space Vector PWM) Digital reference: 0.01Hz (below 99Hz) & 0.1Hz (100Hz and over) Analog reference: 0.03Hz at 50Hz Digital: 0.01% of Maximum output frequency Analog: 0.1 % of Maximum output frequency Linear Square User V/F 1 minute at 150% 30 seconds at 200% (with inverse characteristic proportional to time) Auto Manual (0 15%) FX (forward) RX (reverse) BX (inverter gate blocking) RST (reset) JOG (Jog) Total 3 inputs (programmable) 0 10V linear Input signal Operator control 4 digits LED keypad Terminals ModBus communication Frequency setting Analog: 0 10V, 4 20mA Digital: Keypad Communication: ModBus Start signal Forward Reverse Multi-step operation Setting up to 8 speeds (using multi-function terminal) Multi-step Accel./Decel. time 0.1 6000 seconds. Maximum 8 pre-defined steps using multi-function terminals Operational functions DC braking Frequency limit Frequency jump Second motor function Slip compensation Reverse rotation prevention Auto restart PID controls Emergency stop Interrupting output from inverter Jog Jog operation Fault reset Reset fault signal when protective function is active Output signal Frequency detection Overload alarm Stall Overvoltage Undervoltage Inverter overheat Run Stop Operational status Constant speed Speed search Fault output (Relay and Open collector output) Indicator Output frequency Output current Output voltage DC voltage rpm Protective functions Trip Alarm Overvoltage Undervoltage Overcurrent Inverter overheat Motor overheat I/O phase loss I/O miss wiring Overload Speed command loss Hardware fault Communication error Stall Overload

is5 Starvert is5 Sensorless & sensored vector control Full vector, 150% torque in overall range (continuous torque & speed control) Motor parameter auto-tuning 1 ~ 15kHz carrier frequency Auto speed search Built-in process PID control Multi-motor control (up to 4) 32 characters LCD & 7-segment display keypad Parameter upload & download (LCD Loader Only) Extendable optional I / O sub-boards communication boards: RS485, ModBus, ProfiBus-DP, DeviceNet Built-in Braking IGBT (up to 7.5kW) Precise High Torque Full Vector Control Inverter 0.75 ~ 75 kw Specifications SV008 SV015 SV022 SV037 SV055 SV075 SV110 SV150 SV185 SV220 is5-2u SV300 is5-2u SV370 is5-2u SV450 is5-2u SV550 Motor rating [HP] 1 2 3 5 7.5 10 15 20 25 30 40 50 60 75 [kw] 0.75 1.5 2.2 3.7 5.5 7.5 11 15 18.5 22 30 37 45 55 Output ratings Capacity [kva] 1.9 3 4.5 6.1 9.1 12.2 17.5 22.9 28.2 33.5 46 55 68 84 FLA [A] 5 8 12 16 24 32 46 60 74 88 122 146 180 220 Voltage [V] Three phase, 200 230V Frequency [Hz] 0 400Hz (Sensorless Vector Control: 0 300Hz, Sensored Vector Control: 0 120Hz) Input ratings Voltage [V] Three phase, 200 230V (±10%) Frequency [Hz] 50 60Hz (±5%) SV008 SV015 SV022 SV037 SV055 SV075 SV110 SV150 SV185 SV220 SV300 SV370 SV450 SV550 SV750 Motor rating [HP] 1 2 3 5 7.5 10 15 20 25 30 40 50 60 75 100 [kw] 0.75 1.5 2.2 3.7 5.5 7.5 11 15 18.5 22 30 37 45 55 75 Output ratings Capacity [kva] 1.9 3 4.5 6.1 9.1 12.2 18.3 22.9 29.7 34.3 45 56 68 82 100 FLA [A] 2.5 4 6 8 12 16 24 30 39 45 61 75 91 110 152 Voltage [V] Three phase, 380 460V Frequency [Hz] 0 400Hz ( Sensorless Vector Control: 0 300Hz, Sensored Vector Control: 0 120Hz) Input ratings Voltage [V] Three phase, 380 460V (±10%) Frequency [Hz] 50 60Hz (±5%) Control method Frequency setting resolution Frequency setting accuracy V/F ratio Overload capacity Torque boost Assigned terminals Multi-function input terminals Analog output V/F Control Sensorless Vector Control Sensored Vector Control (Velocity, Torque) selectable Digital reference: 0.01Hz (below 99Hz) & 0.1Hz (100Hz and over) Analog reference: 0.03Hz at 60Hz Digital: 0.01% of Maximum output frequency Analog: 0.1 % of Maximum output frequency Linear Square User V/F 1 minute at 150% 30 seconds at 200% (with inverse characteristic proportional to time) Auto Manual (0 15%) FX (forward) RX (reverse) BX (inverter gate blocking) RST (reset) JOG (Jog) Total 3 inputs (programmable) 0 10V linear Input signal Operator control 32 character LCD keypad 4 digits LED keypad Terminals Communication (ModBus-RTU, RS485, ProfiBus-DP, DeviceNet, F-Net) Frequency setting Analog: 0 10V, 4 20mA, additional port for Sub-Board (0 10V) Digital: Keypad Communication Start signal Forward Reverse Multi-step operation Setting up to 8 speeds (using multi-function terminal) Multi-step Accel./Decel. time 0.1 6000 seconds. Maximum 8 pre-defined steps using multi-function terminals Operational functions DC braking Frequency limit Frequency jump Second motor function Slip compensation Reverse rotation prevention Auto restart Inverter by-pass Auto-tuning PID control Emergency stop Interrupting output from inverter Auto operation Operates from Internal Sequence by Setting Multi-Function Terminal (5Way 8Step) Jog Jog operation Fault reset Reset fault signal when protective function is active Output signal Frequency detection Overload alarm Stall Overvoltage Undervoltage Inverter overheat Run Stop Constant speed Operational status Speed search Fault output (Relay and Open collector output) Inverter by-pass Auto-operation step Auto-operation sequence Indicator Output frequency Output current Output voltage DC voltage Output torque (output voltage: 0 10V) Protective Trip Overvoltage Undervoltage Overcurrent Inverter overheat Motor overheat I/O phase loss I/O miss wiring Fuse open functions Ground fault External fault 1, 2 Option fault Overload Speed command loss Hardware fault Communication error Alarm Stall Overload Temperature sensor fault

ih Starvert Space Vector Control algorithm Volts / hertz control (PWM by IGBT) Constant / Variable torque dual rating 32bits DSP (digital signal processor) 2 ~ 10kHz carrier frequency Built-in process PID control 32 characters LCD display Parameter upload & download 4 ~ 20mA analog output communication boards: RS485, (ModBus, ProfiBus-DP, DeviceNet) Robust Dual Rated High Power Inverter 30 ~ 280 kw, (CT & VT) Specifications SV030 ih-2u SV037 ih-2u SV045 ih-2u SV055 ih-2u SV030 SV037 SV045 SV055 SV075 SV090 SV110 SV132 SV160 SV220 Motor rating Constant Torque [HP] 40 50 60 75 40 50 60 75 100 125 150 175 215 300 Constant Torque [kw] 30 37 45 55 30 37 45 55 75 90 110 132 160 220 Variable Torque [HP] 50 60 75 100 125 150 175 215 250 350 Variable Torque [kw] 37 45 55 75 90 110 132 160 185 280 Output ratings Constant Torque FLA [A] 46 55 68 83 61 75 91 110 152 183 223 264 325 432 (380V based) Constant Torque [kva] 122 146 180 220 40 50 60 70 100 120 145 170 200 280 Variable Torque FLA [A] 80 96 115 125 160 228 264 330 361 477 Variable Torque [kva] 52 62 74 80 103 147 170 213 233 307 Voltage [V] Three phase, 200 230V Three phase, 380 460V Frequency [Hz] 0 400Hz 0 400Hz Input ratings Voltage [V] Three phase, 200 230V (±10%) Three phase, 380 460V (±10%) Frequency [Hz] 50 60Hz (±5%) 50 60Hz (±5%) Control method V/F Control (Space Vector PWM) Frequency setting resolution Digital reference: 0.01Hz (below 99Hz) & 0.1Hz (100Hz and over) Analog reference: 0.03Hz at 60Hz Frequency setting accuracy Digital: 0.01% of Maximum output frequency Analog: 0.1 % of Maximum output frequency V/F ratio Linear Non-linear User V/F Overload Constant Torque 1 minute at 150% 30 seconds at 200% (with inverse characteristic proportional to time) capacity Variable Torque 1 minute at 110% 30 seconds at 150% (with inverse characteristic proportional to time) Torque boost Auto Manual (0 20%) Assigned terminals FX (forward) RX (reverse) BX (inverter gate blocking) RST (reset) Multi-function input terminals Total 6 inputs (programmable) Analog output 0 10V pulse 4 20mA linear Input signal Operator control 32 character LCD keypad Terminals Communication (ModBus-RTU, RS485, ProfiBus-DP, DeviceNet, F-Net) Frequency setting Analog: 0 10V, 4 20mA, additional port for Sub-Board (0 10V) Digital: Keypad Communication Start signal Forward Reverse Multi-step operation Setting up to 8 speeds (using multi-function terminal) Multi-step Accel./Decel. time 0.1 6000 seconds. Maximum 8 pre-defined steps using multi-function terminals Operational functions DC braking Frequency limit Frequency jump Slip compensation PI control Stall prevention Emergency stop Interrupting output from inverter Jog Jog operation Fault reset Reset fault signal when protective function is active Output signal Operational status Frequency detection Overload alarm Stall Overvoltage Undervoltage Inverter overheat Run Stop Constant speed Speed search Indicator Output frequency Output current Output voltage DC voltage rpm Protective functions Trip Alarm Overvoltage Undervoltage Overcurrent Inverter overheat Motor overheat Fuse open Ground fault Overload Main CPU error Stall Overload

2003-05 youngeel@lgis.com srjo@hn.vnn.vn LG Industrial Trading (Shanghai) Co.,Ltd China Address : Room1705-1707, 17th Floor Xinda Commerical Building No 318, Xian Xia Road Shanahai Tel : 86-21-6252-4291 Fax : 86-21-6278-4372 e-mail : jkkimb@lgis.com Room 303, 3F LG Industrial Systems Shanghai Office China Address : Room1705-1707, 17th Floor Xinda Commerical Building No 318, Xian Xia Road Shanahai, China Tel : 86-21-6278-4370 Fax : 86-21-6278-4301 sdkwang@lgis.com LG Industrial Systems Guangzhou Office China Address : Room 303, 3F, Zheng Sheng Building, No 5-6, Tian He Bei Road, Guangzhou, China Tel : 86-20-8755-3410 Fax : 86-20-8755-3408 Variable Frequency Drive / May. 2003 Printed in Korea STAFF