Softstarters. Type SSM Medium voltage ,800V 1. Softstarters

Similar documents
Bulletin 150 Smart Motor Controllers SMC-3 Smart Motor Controller

32VFD Variable Frequency Drives for Centrifugal Chillers

Bulletin 150 SMC Flex Smart Motor Controller Specifications

SUBJECT: How to wire a motor starter Number: AN-MC-004 Date Issued: 2/08/2005 Revision: Original

Medium Voltage Motor Control Assemblies

Product Description Digital Solid State Starting Electric Fire Pump Controllers FTA1930

PSR The compact range Description

VARIABLE FREQUENCY DRIVES Revised 4/30/ Mechanical Systems

BT300 HVAC Drives Conventional Bypass (C-Bypass) Options

Product Description Full Voltage Starting Electric Fire Pump Controllers FTA1000

Product Description Primary Resistance Starting Electric Fire Pump Controllers FTA1500

The HVAC SOLUTION DELIVERING POWER...SAVING ENERGY

AuCom s IMS2 soft starters are a total motor starting solution, combining highlevel functionality with ease of use:

Phone: Fax: Web: info@clrwtr.com

SECTION VARIABLE FREQUENCY DRIVES

Softstarters Type PSR

AMFA-27 AMFA-29. Operator s Manual & Installation Instructions. Rev. 2.5

FFI. Advances in Medium and Low Voltage Power Distribution ESS Metron Expo and Technical Seminars. Presented By: Greg Pelster & Robert Schmid

WYE-DELTA AND SOLID STATE STARTER APPLICATION GUIDE

Permissible ambient temperature Operation Storage, transport

Product Description Full Voltage Starting Electric Fire Pump Controllers FTA1000

Low Voltage Fuses For Motor Protection

How To Build A Germany Power Plant

Secondary Unit Substations

2a. IEM Indoor Metal Clad Medium Voltage Switchgear 15KV a. Section INDOOR METAL CLAD MEDIUM VOLTAGE SWTICHGEAR (Std.

SUGGESTED SPECIFICATION for Series 185 Service Entrance Rated Automatic Transfer Switches

Specifying a Variable Frequency Drive s

SAFETY PRECAUTIONS AND INSTRUCTIONS FOR USE OF TECHNICAL INFORMATION

WITH POWER TRANSFER SWITCH STANDARD SUBMITTAL PACKAGE

Installation and Maintenance manual. Softstarters PST / PSTB

APC Matrix-UPS 5kVA 208V/240V In 120/208/240V Out

Panorama. Softstarters The complete range

PRODUCT GUIDE. SL Medium Voltage IEC Vacuum Contactors

RVS-DXM Instruction Manual

VLT Series 3500 Adjustable Frequency Drive Instruction Manual

NC-12 Modbus Application

TP-C2 Motor Operator CLEAVELAND / PRICE INC. Bulletin DB-111B12

8146/5 Series Breaker Panelboards

Applications. Remote Display Mounting Kits

AUTOMATIC TRANSFER SWITCH. Changeover Type from 250A to 2500A

Softstarters. Type PST/PSTB Fieldbus communication CANopen for PST sw CU SFC132070M0201 February SFC132070M0201 1

MC Series Drives. Flexible, simple, rugged, robust! Phone: Fax: Web: info@actechdrives.

Bussmann. All-In-One Module. Bussmann Power Module Switch. How to configure Part Numbers: Step 1: Select Switch Amperage 1

SWITCHGEAR SOLUTIONS FOR MISSION CRITICAL APPLICATIONS. Presented by SAI Advanced Power Solutions

Products and solutions for lifting systems

Single Phase Soft Starter

CONSTRUCTION STANDARDS DIVISION 23 HEATING VENTILATING AND AIR CONDITIONING

Diesel Engine Driven Generators Page 1 of 6

Thyristor-controlled power supplies and battery chargers

DC UPS. RTB.e A. IMB.e/ITB.e kva. E2001.e/E3001.e kva. Input voltage: 110/125/220 Vdc. 115/120/230 Vac, 1-phase (IMB.

Number 1 in efficiency

GE Industrial Solutions ASTAT BP. User Manual

... Electronic Softstarter...

..OR How To Protect your 3-Phase Equipment Investment with 3-Phase Monitors from Time Mark...

Eaton Automatic Transfer Switches

XFE. The cost effective starter for all AC induction motors from 4A 2800A The choice for small to medium industrial applications

Phone: Fax: Web: info@clrwtr.com

Reduced Voltage Starters Section 2

Series TS Amp. Automatic Transfer Switches

SOFT-STARTER MANUAL. Series: SSW E/2

RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features:

TC 1818a. Operating Guide. Control Module SWM-015.5

Specification CyberWave UPS Ver /01/00

Softstarters. Type PST30...PSTB1050 Installation and Commissioning Manual. Manual 1SFC132003M0201 June Fault. Power on Protection

HVL 5 38 kv Load Interrupter Switchgear. The Standard for Performance, Protection and Dependability

3) What is the difference between "Insulating", "Isolating", and "Shielded Winding" transformers?

US Breaker Brand 3 Pole AC Contactors (Square D Telemecanique LC1 Replacements)

Fractional to 2 HP DC Drives for Both Non-Regenerative and Regenerative Applications

Ω POWEROHM RESISTORS, INC. Braking Resistors for Variable Frequency Drives APPLICATION SELECTING A STANDARD DESIGN CUSTOM RATINGS

UNIVERSITY OF WASHINGTON Facilities Services Design Guide. Electrical. Metering and Monitoring. Basis of Design

MEDIUM VOLTAGE CE-BF SWITCHBOARDS. UP TO 40.5 kv. CE - BF - C - en - REV

REVIEWED BY CAPITAL PROJECTS MANAGER (DAN REDDY) GENERAL MANAGER EQUIPMENT ENGINEERING & ASSET MANAGEMENT (HAMILTON NXUMALO)

Section TELEPHONE AUTOMATIC DIALER SYSTEM

How To Test A Power Switch On A Power Supply

Distribution Voltage Regulators

AIS 3000 APC AIS kVA 208V w/2 Batt. Module Exp. To 4, Start-Up 5X8, Internal Maintenance Bypass

Product Guide AC Voltage Control Devices. Guide Guide. Popular Variable Transformers and AC Power Supplies.

DIALER SPECIFICATION VERBATIM MODULAR SERIES VSS

Eaton s E-Series protective relay family

MEDIUM AND HIGH VOLTAGE CAPACITORS, CAPACITOR BANKS AND SYSTEMS

SMC -3 Specifications

SENTRA SERIES WATER UNITS. 30 to 300 F Process Temperatures. 1/2 to 7.5 HP Centrifugal Pumps ( GPM) 10 to 34 KW Stainless Steel Heaters

REGAL-BELOIT. Installation and Operation Manual. Variable Speed AC Motor Drives. Micro and PowerWash Series

RVS-DX Instruction Manual

Electronic Control Devices The European Product Catalogue 2007

THERMAL MANAGEMENT SOLUTIONS

MC1000 Series Installation and Operation Manual

Submit shop drawings for equipment provided under this section Shop drawings shall indicate:

2011 Industrial Catalog. DRIVES, PAC, PLCs. Industrial Catalog

Products and solutions for pumping, irrigation and piping

MTE SERIES RLW. World REACTORS USER MANUAL PART NO. INSTR 030 REL MTE Corporation

RVS-DX Instruction Manual

*.ppt 11/2/ :48 PM 1

T 3 Series VAV Diffusers Analog Diffuser Steel Square Panel Horizontal Pattern Model: T 3 SQ

Limited Service Fire Pump Controllers Features

920 Series. Dual-point heat-tracing control system. Product overview. 920*E4FWL*SIS302*SS3102 shown

CAT ATC POWER BREAKER & POWER CASE SWITCH AUTOMATIC TRANSFER SWITCH

MicroVersaTrip Plus & MicroVersaTrip PM Conversion Kits for GE Power Circuit Breakers

Sentron Series Circuit Breakers

VLT 6000 HVAC. Contents

Transcription:

Softstarters Medium voltage 2300 13,800V 1 Softstarters Description Fused disconnect switch with blown fuse indicators and door safety interlocks rated for load break/fault make with automatic grounding arm Inline isolation vacuum contactor sized for across-the-line motor starting (optional on "soft start only" models) Bi-metallic thermal overload provides backup motor protection when operating in emergency bypass mode (optional on "soft start only" models) 120V fused control power transformer standard in line start section (optional on "soft start only" models) Digital controller provides solid state overload and numerous protective features for both the motor and the soft starter Fiber optic firing circuit for superior electrical noise isolation Programmable keypad with LCD and status LEDs for easy setup and operation Bypass vacuum contactor sized for across-the-line (emergency) motor starting is standard on all models to guarantee cool operation in all environments and extend unit life Heavy duty SCR stack assemblies with ring transformer isolated circuit for reliable, hard-firing gate pulse Isolated low voltage compartment provides maximum protection for operating personnel Mechanically interlocked medium voltage compartment UL File # E175732 2 1 Consult factory for higher voltages. 2 For softstarters rated 410V, 400A and below. Low Voltage Products & Systems.51

Softstarters General information Key construction features Fused disconnect switch with blown fuse indicators and door safety interlocks rated for load break/fault make with automatic grounding arm Inline isolation vacuum contactor 2 sized for across-the-line motor starting (optional on "soft start only" models) Bi-metallic thermal overload provides backup motor protection when operating in emergency bypass mode (optional on "soft start only" models) 120V fused control power transformer standard in line start section (optional on "soft start only" models) Digital controller provides solid state overload and numerous protective features for both the motor and the soft starter Programmable keypad with LCD and status LEDs for easy setup and operation Bypass vacuum contactor 2 standard on all models to guarantee cool operation in all environments and extend unit life Heavy duty SCR stack assemblies with ring transformer isolated circuit for reliable, hard-firing gate pulse Isolated low voltage compartment provides maximum protection for operating personnel Mechanically interlocked medium voltage compartment Heavy duty SCR power assemblies Rated for 500 percent overload for 0 seconds Field-proven design in use since 1975 Fiber optics gate-firing circuit using ring transformer isolation design for superior noise immunity Industrial real world packaging Load break/fault make disconnect switch with door safety interlocking mechanism Isolated, noise-immune low voltage control compartment NEMA 12 enclosure with bypass vacuum contactor included as standard 12 Extra wiring space for MV cables for easy installation Custom engineered systems Available in special enclosures and lineups Numerous control component options including: Reversing contactors Motor protection relays Customer specified devices Horizontal and custom bus interconnects Various motor configurations including synchronous, wound rotor and two speed Digital microprocessor control Full featured for flexibility, including dual ramp and programmable custom start curves LCD status/alarm display and built-in programing keypad Serial communications port standard: RS485 with Modbus RTU protocol or RS232 with Windows interface In-depth motor and system protection monitors Monitors 18 separate parameters and maintains a nonvolatile fault memory 1 13.8 kv softstarters are rated NEMA 1. 2 13.8 kv, 00A softstarters use circuit breakers for isolation and bypass functions..52 Low Voltage Products & Systems

Softstarters Ratings 1 Soft start with line start section Optional soft start only 2 Volts Max. Nominal Catalog List Catalog List amps max. HP number price number price 200 800 SSM-23200-E-S SSM-23200-E 2300 400 1500 SSM-23400-E-S 3 SSM-23400-E 3 00 2500 SSM-2300-E-S SSM-2300-E 200 1000 SSM-33200-E-S SSM-33200-E 3300 400 1800 SSM-33400-E-S 3 SSM-33400-E 3 00 3000 SSM-3300-E-S SSM-3300-E 200 1250 SSM-41200-E-S SSM-41200-E 410 400 2500 SSM-41400-E-S 3 SSM-41400-E 3 00 5000 SSM-4100-E-S SSM-4100-E 00/ 900 13,800 200 2500 SSM-200-E-S SSM-200-E 400 5000 SSM-400-E-S 3 SSM-400-E 3 00 7500 SSM-00-E-S SSM-00-E 300 7500 SSM-138300-E-S 3 SSM-138300-E 00 15,000 SSM-13800-E-S SSM-13800-E 3 Custom line-up SSM-41200-E-S Catalog number explanation SSM - 23 200 - E - S Softstarter SSM medium voltage Voltage 23 = 2300V 33 = 3300V 41 = 410V = 00/900V 138 =13,800V S = Switchgear line start panel E = NEMA 12 enclosure 45 Amperage 200 = 200A 400 = 400A 00 = 00A 1 Contact factory for higher horsepower and voltage requirements. 2 Must be used with customer supplied line start panel. 3 Consult factory. 4 Consult factory for other enclosure types. 5 13.8 kv softstarters are rated NEMA 1. Low Voltage Products & Systems Discount schedule SSME.53

Softstarters Technical data Type of load Three phase medium voltage AC induction motors AC supply voltage 2300, 3300, 410, 00/900, 13,800 VAC +10% to -10% 50/0 Hz line voltages HP ratings 1 Up to 15,000 HP @ 13,800V (00 Amps max) Overload rating 500% 0 Seconds Power circuit Series strings of SCR power modules (2,4 or matched pairs of SCRs per phase depending on voltage rating) SCR peak inverse voltage Amps Line voltage PIV rating 2300 V 500 200 to 3300 V 13,000 400 410 V 13,000 00/900 V 19,500 11-14 kv 39,000 2300 V 7000 3300 V 14,000 00 410 V 14,000 00/900 V 21,000 11-14 kv 39,000 Transient voltage protection dv/dt circuits (1 per SCR power module) Vacuum bypass contactor 3 Standard on all models, line start rated Ambient operating temperature 0 to 50 C (32 F to 122 F) (Optional -20 to 50 C with heaters) Control Digital microprocessor controller with read-out in English text Alphanumeric LCD display Non-volatile memory for programming and faults Opto-isolated inputs Communications RS485 with modbus RTU protocol RS232 with Windows interface Auxiliary contacts FORM C, 8 Amps @ 250V Adjustments Motor FLA Dual adjustments Two independent settings for: Initial voltage 0 100% of nominal voltage Current limit 0 00% of motor FLA Acceleration time 1 120 seconds Deceleration time 1 0 seconds Kick start 0.1 2.0 seconds, 10-100% of line voltage Under voltage trip 70 95% (adjustable trip delay) Over voltage trip 105 130% (adjustable trip delay) Under current trip 20 90% of motor FLA (adjustable trip delay) Over current trip 100-300% of motor FLA (adjustable trip delay) Allowable re-starts 0 10 (adjustable time inhibit) Motor and starter protection Electronic overload Inverse time, 75 150% of motor FLA Electronic shear pin Trips within 1 cycle of setpoint Phase loss One or more phases missing Phase sequence Phase sequency incorrect Over voltage Trips at high line setpoint Under voltage Trips at low line setpoint Stall protection Starting process is not complete Shorted SCR Internal fault detected Error connection Internal fault/motor connection Starter over-temp Heatsink over temperature Metering Current Phase A, B, C & average current Thermal data Thermal capacity of motor Power KVA, KW, KVAR, power factor, KWH Line start section Load break/fault make disconnect switch with automatic grounding arm and viewing window Fuses with blown fuse indicator In-line vacuum contactor3 Control power transformer with fused primary/secondary Packaged in common enclosure with soft start Optional "Soft Start" (requires customer supplied line start panel) Statistical data Total amount of run time since soft start was reset Amount of time it took motor to start during last period Maximum current during last start period Total number of starts since soft start was reset Event history for last 0 events Elevation 1000 m / 3300 ft. without derating (contact factory for higher elevations) Enclosure 2 NEMA 12, top and bottom entrance plates 11 gauge steel ASA #1 gray paint with lifting eyes 1 Consult factory for higher horsepower and voltage requirements. 2 13.8 kv softstarters are rated NEMA 1. 3 13.8 kv, 00A softstarters use circuit breakers for isolation and bypass functions..54 Low Voltage Products & Systems

Approximate dimensions Softstarters B C A Soft start with line start section (inches) Optional softstart only (inches) Model number A B C Model number A B C SSM-23200-E-S 92 3 30 SSM-23200-E 92 3 30 SSM-23400-E-S 92 3 30 SSM-23400-E 92 3 30 SSM-2300-E-S 92 72 30 SSM-2300-E 92 3 30 SSM-33200-E-S 92 3 30 SSM-33200-E 92 3 30 SSM-33400-E-S 92 3 30 SSM-33400-E 92 3 30 SSM-3300-E-S 92 72 30 SSM-3300-E 92 3 30 SSM-41200-E-S 92 3 30 SSM-41200-E 92 3 30 SSM-41400-E-S 92 3 30 SSM-41400-E 92 3 30 SSM-4100-E-S 92 72 30 SSM-4100-E 92 3 30 SSM-200-E-S 92 72 30 SSM-200-E 92 3 30 SSM-400-E-S 92 72 30 SSM-400-E 92 3 30 SSM-00-E-S 92 72 30 SSM-00-E 92 72 30 SSM-138300-E-S 92 120 44 SSM-138300-E Consult factory SSM-13800-E-S 92 84 9 SSM-13800-E Low Voltage Products & Systems.55

Softstarters Notes.5 Low Voltage Products & Systems