WIRING SCHEMES 19mm, 22mm, 30mm Switches

Similar documents
Specifications for EM VDC 4 In/4 Out and EM VDC 4 In/4 Relay Out

THE INPUT/OUTPUT SYSTEM. Key Points

Modular I/O System Analog and Digital Interface Modules

Transformer circuit calculations

38 SERIES. Relay interface modules A. EMR Electromechanical Relays. Common features. SSR Solid State Relays. 6.

38 Series - Relay interface modules A

38 Series - Relay interface modules A

SUBJECT: How to wire a motor starter Number: AN-MC-004 Date Issued: 2/08/2005 Revision: Original

48 SERIES Relay interface modules 10 A

Whale 3. User Manual and Installation Guide. DC Servo drive. Contents. 1. Safety, policy and warranty Safety notes Policy Warranty.

49 Series - Relay interface modules A. Features

Wires & Connections Component Circuit Symbol Function of Component. Power Supplies Component Circuit Symbol Function of Component

Figure 1 - Crydom 3RHP Three-phase Hybrid Solid State Contactor. Crydom Inc.

Digital Expansion Modules Specifications

1 POLE - 16A 80A Inrush type. (b) Contact configuration A : 1 form A (SPST-NO) C : 1 form C (SPDT) (standard type "K" only)

Programming A PLC. Standard Instructions

3 Slot Payphone Controller

Diode Applications. As we have already seen the diode can act as a switch Forward biased or reverse biased - On or Off.

DC DC CONVERTER 1000W VDC Input / 12VDC Output

GLOLAB Two Wire Stepper Motor Positioner

CONSTRUCTING A VARIABLE POWER SUPPLY UNIT

What is a multimeter?

LM 358 Op Amp. If you have small signals and need a more useful reading we could amplify it using the op amp, this is commonly used in sensors.

3BASIC RELAY INSTRUCTIONS

GenTech Practice Questions

Rectifier circuits & DC power supplies

POWER SUPPLY MODEL XP-15. Instruction Manual ELENCO

SWITCH! DESCRIPTION. ENVIRONMENTAL SPECIFICATIONS Operating Temperature: 0 C to +40 C SPECIFICATION SHEET:

Electrical Safety Tester Verification

PS4-24 OWNERS MANUAL 24 VAC 90 WATT WALL MOUNTED CCTV POWER SUPPLY

DC Motor control Reversing

pole, 8 A Safety relay. Screw terminal. 35 mm rail (EN 60715) mounting. 2 CO (DPDT) 8/15 250/400 2, /0.65/0.

Features. Applications. Truth Table. Close

Application Note AN-1068 reva

MAXIMUM LOAD CURRENT 1 A SN SERIES

Odyssey of the Mind Technology Fair. Simple Electronics

AZ420 MINIATURE GENERAL PURPOSE RELAY

Programming Logic controllers

Troubleshooting Guide, Freedom and Fleet Power Inverter/Chargers

40 Series - Miniature PCB/Plug-in relays A. Features

60 Series - General purpose relays 6-10 A. Features

2011, The McGraw-Hill Companies, Inc. Chapter 5

GENERATOR START CONTROL MODULE - MINI (2 Wire to 3 Wire)

The Interaction of Contactors with PLCs

AC/DC Track Circuit System OS and Fouling Circuit Applications

SX460. Generator Automatic Voltage Regulator Operation Manual

1 POLE - 16A / Inrush 120A relay. (a) Relay type FTR-K1 : FTR-K1 Series (b) Contact configuration A : 1 form A C : 1 form C

ECEN 1400, Introduction to Analog and Digital Electronics

Points Position Indicator (PPI1) for Points Motors with Common Ground

Type SA-1 Generator Differential Relay

12S, 14S, 15S Series. Time Delay Relays and Sequencers. Time Delay Relays and Sequencers. Features and Benefits. Switch Actions and Configurations

LMU Hardware and Installation Guide

Switch Selection Guide

2 POLES - 5A LOW PROFILE TYPE

Digital I/O: OUTPUT: Basic, Count, Count+, Smart+

SKR - industry relay

1 POLE - 8A Medium Load Control

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N

S112-XHS. Description. Features. Agency Approvals. Applications. Absolute Maximum Ratings. Schematic Diagram. Ordering Information

Impulse G+/VG+ Series 3, 24 VDC Interface Card Terminal Designations

Solid State Relays Industrial, 1-Phase ZS w. LED Types RS 23, RS 40, RS 48

Solid-State Relays (SSRs) vs Electromechanical Relays (EMRs)

CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (4-20 ma Input Version)

Fiber Optic Selector Guide for Analog & Digital Data Links, Contact Closures & Multiplexers

Diode Applications. by Kenneth A. Kuhn Sept. 1, This note illustrates some common applications of diodes.

RT series Miniature Printed Circuit Board Relays, Sockets and Accessories

34 Series - Slim electromechanical PCB relays 6 A. Features SERIES 34.51

Allen-Bradley/Rockwell

Table 1 Comparison of DC, Uni-Polar and Bi-polar Stepper Motors

AP Physics Electricity and Magnetism #4 Electrical Circuits, Kirchoff s Rules

LED DIMMING A HELPFUL GUIDE...

1 POLE - 16A 80A Inrush type. (a) Relay type FTR-K1 : FTR-K1-Series

Lab 1: DC Circuits. Student 1, Partner : Student 2, student2@ufl.edu

POINTS POSITION INDICATOR PPI4

OPERATING MANUAL. Table of contents. 2 Phase Stepping Motor Driver 2M542. Rev. A. Introduction page 2. Specifications page 2 Timing chart page 3

Telefon (+45) Telefax (+45) Installation and operating manual

MasterINTERFACE 39 Series - Relay interface modules

ELECTRONIC POWER SYSTEMS

Instruction Manual. 2in1 LAN Tester & Multimeter. Model: LA-1011

DMX-K-DRV. Integrated Step Motor Driver + (Basic Controller) Manual

Inductive Sensors Single or Dual Loop Detectors Type LD with teach-in

SZR-LY Series. General Purpose Power Relay WARNING WARNING. Sensing and Control

RADIANT PLASMA 4700 Plasma Spark Generator

IO-RM3 3-Stage Relay Module

1 pole, 16 A Screw terminal connection 35 mm rail (EN 60715) mounting. 2 pole, 8 A Screw terminal connection 35 mm rail (EN 60715) mounting

Model 201 Wiegand Touchpad Reader Installation Guide

Parts list and Notes for making a 10 hp 240V single phase to 240V 3-phase converter.

NTE923 & NTE923D Integrated Circuit Precision Voltage Regulator

Electronics. Discrete assembly of an operational amplifier as a transistor circuit. LD Physics Leaflets P

Standex-Meder Electronics. Custom Engineered Solutions for Tomorrow

AP-1 Application Note on Remote Control of UltraVolt HVPS

NA Series. 2 POLES - 1 to 2 A (For Signal Switching) MINIATURE RELAY FTR-K1 SERIES

RADIO FREQUENCY IDENTIFICATION (RFID) GARAGE DOOR ENTRY SYSTEM

L293B L293E PUSH-PULL FOUR CHANNEL DRIVERS. OUTPUT CURRENT 1A PER CHANNEL PEAK OUTPUT CURRENT 2A PER CHANNEL (non repetitive) INHIBIT FACILITY

Inductors in AC Circuits

Solid-State Relays. Series Included. Solid-State Relays SIR SLR NLF PHS Series PHS...148

MLC TM Maximum Productivity and Versatility for Control without Compromise!

Y.LIN ELECTRONICS CO.,LTD.

Exploring the Necessity of the Hot Hipot Test

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

Transcription:

DIGITAL OUTPUT (RMALLY LOW) DIGITAL OUTPUT (RMALLY HIGH) OPEN COLLECTOR SINKING OUTPUT 0V 5V 0V 5V 5V or 10V 24V Actuated Voltage = 5V (Max) Output Current = 20mA (Max) Actuated Voltage = 0V Output Current = 20mA (Max) Sinking Current = 100mA (Max) In the untouched state the switch output is 0 VDC. When touched, the output is 5 VDC with a maximum current of 20mA (100mW). This ActiveMetal configuration is commonly used to communicate with a control device. In the untouched state the switch output is 5 VDC, with a maximum current of 20mA (100mW). When touched, the output becomes 0 VDC. This ActiveMetal configuration is commonly used to communicate with a control device. For a Normally Open switch the output line is open in the untouched state. In the touched state the output line is pulled to ground, completing a circuit. The states are reversed for a Normally Closed switch the output line is pulled to ground in the untouched state and open in the touched state. The switch can sink up to 100mA. OPEN COLLECTOR SINKING OUTPUT LOW POWER LOAD (DC) OPEN COLLECTOR SINKING OUTPUT LOW POWER RELAY VDC VDC Load Protection Diode 5V or 10V 24V 5V or 10V 24V Sinking Current = 100mA (Max) Sinking Current = 100mA (Max) High Power AC or DC Load Using a normally open switch, in the untouched state the output line is open. In the touched state the output line is pulled to ground sinking up to 100mA. This configuration could be used to directly control DC devices of less than 100mA. In the untouched state the output line is open. In the touched state the output line is pulled to ground and can sink up to 100mA. When wired to the low side of a relay coil, this configuration could be used to energize a relay and control higher power DC or AC devices.

ACTIVEMETAL WITH A LOGIC PLC INPUT MODULE Interfacing with a PLC can be accomplished in a number of ways, depending on the I/O for the PLC. Following are three possibilities. 5VDC Input 0 Input 1 A 0 1 The example to the left shows the connection between an ActiveMetal 5V digital output switch and an Allen Bradley 1771-IG logic input module. Input 2 Input 3 Input 4 Input 5 2 3 4 5 Note that ActiveMetal Switches can be Normally High or Normally Low ; the PLC programming should reflect the type of switch used and function desired. Input 6 6 Input 7 DC Common 7 8 Actual wiring runs in this direction ACTIVEMETAL WITH A SOURCING (SINK LOAD) PLC INPUT MODULE A Normally Open Open Collector ActiveMetal Switch is wired into a sourcing PLC input module in the example to the left. DC Input 0 Input 1 Input 2 Input 3 Input 4 Input 5 A 0 1 2 3 4 5 Note that the above examples are neither an endorsement of Allen-Bradley PLCs, or by Allen Bradley of ActiveTouch. They are examples of how an ActiveMetal switch could be used with a PLC based on readily available public information. Using an ActiveMetal switch with other manufacturers PLC input modules will likely require comparable considerations. Input 6 Input 7 Not Used 6 7 8 10 Actual wiring runs in this direction

ACTIVEMETAL WITH A SINKING (SOURCE LOAD) PLC INPUT MODULE Not Used Input 0 Input 1 Input 2 Input 3 Input 4 Input 5 Input 6 Input 7 DC Common A 0 1 2 3 4 5 6 7 8 10 Pull-Up Resistor A Normally Closed Open Collector ActiveMetal Switch is wired into PLC sinking input module as shown in the graphic on the left. The value of the pull-up resistor will vary based on the PLC input module used and supply voltage. The example to the left shows the Allen Bradley 1771-IB that has an input impedance of 1K to 2K in the on-state. Minimum on state voltage is 10VDC. A minimum on-state input current can be calculated of 5mA to 10mA. With a 24V supply, a 2.4K Ohm pull-up resistor would allow 10mA input into the PLC. Allowing the PLC input impedance to limit the current flow is recommended. The resistor for this example would be a maximum of 2.4K Ohms at 0.5 Watts. Actual wiring runs in this direction DIGITAL OUTPUT ACTIVEMETAL CONTROLLING A SOLID STATE RELAY Solid State A low power solid state relay can be controlled by a Digital Output ActiveMetal switch (left) or an Open Collector ActiveMetal switch (next page). The ActiveMetal Digital Output is 5VDC and 20mA. This output should meet this solid state relay s input requirements of an input voltage of 3-30VDC and input current of 5-40mA as noted on the following page. DC Load Circuit

ACTIVEMETAL CONTROLLING A SOLID STATE RELAY EXAMPLE OF SOLID STATE RELAY Specifications Component Type Mounting Type Rated Current Load Contact Configuration Control Voltage Load Type Input Voltage Range Output Voltage Range Switching Type Output Characteristics Pull-up Resistor Solid State Panel 5A SPST- DC DC 3 30 VDC 3 60 VDC DC Switching Switching Device Triac Current Rating 5A Switching Voltage 3 60 VDC Minimum Load Current to Maintain On 100 ma Non-Repetitive Surge Current (1 Cycle) 7 (1 Sec) A Maximum Off State Leakage Current (rms) 10 µa Minimum Peak Blocking Voltage 105 VDC Typical On State Voltage Drop (rms) 1.85 VDC Input Characteristics Voltage Range Must Release Voltage Typical Input Current @ 5 VDC or 240 VAC Maximum Reverse Control Voltage 3 30 VDC 1 VDC 5 40 ma 3 VDC Solid State DC Load Circuit For solid state relays requiring higher input voltages, the Open Collector ActiveMetal with pull-up resistor would be required as shown in the illustration to the left. A Normally Open relay will require a Normally Closed ActiveMetal switch for the load circuit to be open in the untouched switch state. Alternatively, a Normally Closed relay paired with a Normally Open ActiveMetal switch will produce an open load circuit in the untouched state. SIZING THE RESISTOR The maximum size of the pull-up resistor will be determined by the current requirements to drive the relay. For this example, the relay is normally open with an input voltage of <1VDC. With an input voltage of >3V and input current >5mA the contacts close and can pass 5A. The pull-up resistor must allow enough current to drive the solid state relay. Assuming 24VDC input, the resistor value can be calculated as Resistance = Voltage / Current, or V 24VDC R= = = 4800 Ω C 0.005AMPS 4.7K Ohms is a common resistor size. The current supplied to the relay will increase slightly with the lower resistor value, but is well within the 100mA capability of the ActiveMetal switch: V 24VDC C = = = 0.0051 AMPS R 4700 Ω The wattage of the resistor can be calculated as Power = Current 2 * Resistance, or (0.0051 Amp) 2 * (4700 Ohm) = 0.123W. A quarter watt 4.7K Ohm resistor should be sufficient for this application.

ACTIVEMETAL SWITCHING 110 VAC OR 220 VAC Protection Diode Hot 110 VAC Load 110 VAC In Neutral 110 VAC / Regulator The schematics on the left are for using an Open Collector ActiveMetal switch to control power to a 110V or 220V device. Notes: 1. The 24VDC coil relays shown in the diagrams are powered from the same source as the ActiveMetal switches (12V or 24V DC regulator or power supply). 2. In both examples, the relay coil current must be less than 100mA. The 220V example uses a pilot relay to control the current to the AC coil of the larger Double Pole Double Throw (DPDT) relay. 3. The electromechanical relays controlled by the ActiveMetal switch have a protection diode (D1) across them to dissipate the energy in the coils when they are de-energized. The diode size is such that the diodes forward current exceeds the relay coil current and the dode s reverse voltage is several times the operating voltage of the coil. 220 Load D1 Comm Out PE 110 VAC In 110 VAC / Regulator 120 VAC DPDT Coil Comm Neutral White (L1) (L2) 220 VAC Supply PE

TROUBLE SHOOTING ACTIVEMETAL SWITCH WIRING Goal: Provide information for an individual to confirm the switch is wired correctly using a hand held multimeter. DIGITAL OUTPUT (5VDC INPUT) Switch Status: Normally High Normally Low Switch Action:* Momentary Momentary Confirm Input: Wire (V) (Voltage relative to black wire) 5VDC 5VDC Output in Untouched state: Wire (Voltage relative to black wire) 5VDC /- 10% <0.5VDC Output in Touched state: Wire (Voltage relative to black wire) <0.5VDC 5VDC /- 10% *Alternate Action switches toggle between the Untouched and Touched states of the momentary switches. OPEN COLLECTOR OUTPUT Input: 5VDC 5VDC 10 24VDC 10 24VDC Switch Status: Normally Open Normally Closed Normally Open Normally Closed Switch Action:* Momentary Momentary Momentary Momentary Confirm Input: Wire (V) (Voltage relative to black wire) 5VDC 5VDC 10 24VDC 10 24VDC Output in Untouched state: Wire (Equivalent resistance relative to black wire) >1 MOhm <1 Ohm >1 MOhm <1 Ohm Output in Touched state: Wire (Equivalent resistance relative to black wire) <1 Ohm >1 MOhm <1 Ohm >1 MOhm TE: Maximum current sinking capability is 100mA. *Alternate Action switches toggle between the Untouched and Touched states of the momentary switches.