Modeling Choked Flow Through an Orifice

Similar documents
Chapter 10. Flow Rate. Flow Rate. Flow Measurements. The velocity of the flow is described at any

FLOW MEASUREMENT 2001 INTERNATIONAL CONFERENCE DERIVATION OF AN EXPANSIBILITY FACTOR FOR THE V-CONE METER

FLUID FLOW Introduction General Description

Michael Montgomery Marketing Product Manager Rosemount Inc. Russ Evans Manager of Engineering and Design Rosemount Inc.

THEORETICAL UNCERTAINTY OF ORIFICE FLOW MEASUREMENT page 1 THEORETICAL UNCERTAINTY OF ORIFICE FLOW MEASUREMENT INTRODUCTION COEFFICIENT OF DISCHARGE

Head Loss in Pipe Flow ME 123: Mechanical Engineering Laboratory II: Fluids

The Use of Control Valve Sizing Equations with Simulation Based Process Data

Valve Sizing. Te chnic al Bulletin. Flow Calculation Principles. Scope. Sizing Valves. Safe Product Selection.

Application of the Orifice Meter for Accurate Gas Flow Measurement page 1. Application of the Orifice Meter for Accurate Gas Flow Measurement.

BASIC UNDERSTANDING OF FLOW CALCULATIONS AND ESTIMATES MAKES SIZING VALVES SIMPLER

Experiment # 3: Pipe Flow

High Speed Aerodynamics Prof. K. P. Sinhamahapatra Department of Aerospace Engineering Indian Institute of Technology, Kharagpur

RITTER Multiple Sonic Nozzle Calibration System

Experimental Evaluation of the Discharge Coefficient of a Centre-Pivot Roof Window

Air Flow Optimization via a Venturi Type Air Restrictor

Custody Transfer Measurement. with the V-Cone Flowmeter

Testing Protocol for Differential Pressure Measurement Devices API MPMS Chapter 22.2

A LAMINAR FLOW ELEMENT WITH A LINEAR PRESSURE DROP VERSUS VOLUMETRIC FLOW ASME Fluids Engineering Division Summer Meeting

4.What is the appropriate dimensionless parameter to use in comparing flow types? YOUR ANSWER: The Reynolds Number, Re.

Theory overview of flow measurement using differential pressure devices based on ISO-5167 standard.

inter.noise 2000 The 29th International Congress and Exhibition on Noise Control Engineering August 2000, Nice, FRANCE

Advanced Differential Pressure Flowmeter Technology V-CONE FLOW METER TECHNICAL BRIEF

INTRODUCTION TO FLUID MECHANICS

Grant Agreement No SFERA. Solar Facilities for the European Research Area SEVENTH FRAMEWORK PROGRAMME. Capacities Specific Programme

Chokes. Types Reasons Basics of Operations Application

Flow Measurement. Reference - Flow Measurement FUNDAMENTALS. ρ = fluid density (lb/ft3 or kg/m3)

CO MPa (abs) 20 C

measurement, but almost any pipe elbow can be calibrated Elbow meters are not as potentially accurate as venturi,

By Authority Of THE UNITED STATES OF AMERICA Legally Binding Document

Energy Systems Engineering Technology

APPENDIX A CONTROL VALVE TESTING PROCEDURES AND EQUATIONS FOR LIQUID FLOWS

Equivalents & Conversion Factors 406 Capacity Formulas for Steam Loads 407 Formulas for Control Valve Sizing

Heat Transfer Prof. Dr. Ale Kumar Ghosal Department of Chemical Engineering Indian Institute of Technology, Guwahati

Experiment 3 Pipe Friction

Fluids and Solids: Fundamentals

Chapter 8: Flow in Pipes

Fluid Flow Instrumentation

C. starting positive displacement pumps with the discharge valve closed.

Water hammering in fire fighting installation

HOW TO SIZE A PRESSURE REGULATOR

Fundamentals of Orifice Meter Measurement page 1. Fundamentals of Orifice Meter Measurement. What is an Orifice Meter? How does it work?

pressure inside the valve just before the final release of air. in pipeline systems resulting from 2p 1 p a m C D A o

PULSATION REDUCTION BY ACOUSTIC FILTERS FOR METERING APPLICATIONS. Robert J. McKee Ray G. Durke

Air Flow Measurements

Lecture 6 - Boundary Conditions. Applied Computational Fluid Dynamics

Averaging Pitot Tubes; Fact and Fiction

Flow Measurement in Pipes and Ducts. Flow Measurement in Pipes and Ducts, Course #503. Presented by:

V-Cone, An Alternative to Orifice Meter in Wet Gas Applications

Sizing Pressure Regulators & Control Valves

DEVELOPMENT OF HIGH SPEED RESPONSE LAMINAR FLOW METER FOR AIR CONDITIONING

Minor losses include head losses through/past hydrants, couplers, valves,

Chapter 17. For the most part, we have limited our consideration so COMPRESSIBLE FLOW. Objectives

Advances in Thermal Dispersion Mass Flow Meter Accuracy

Rosemount Orifice Plate in Wet Gas

Establishment of the Gas Flow Calibration Facility at CSIR-NPL, India

AN INSTRUMENT FOR GRAVIMETRIC CALIBRATION OF FLOW DEVICES WITH CORROSIVE GASES. J. O. Hylton C. J. Remenyik Oak Ridge National Laboratory *

Flow System Calibration in Medical and Bio-medical Production Processes.

Dimensional analysis is a method for reducing the number and complexity of experimental variables that affect a given physical phenomena.

Using meters to measure steam flow

191: Calibration and Standards in Flow Measurement. Richard Paton National Engineering Laboratory, Scotland, UK 1 GENERAL PRINCIPLES

The Unique Accelabar Flow Meter

CONTROL VALVE PRESSURE DROP AND SIZING

IPACK DISTRIBUTED LEAKAGE FLOW IN RAISED-FLOOR DATA CENTERS

Appendix 4-C. Open Channel Theory

Pressure drop in pipes...

Experiment (13): Flow channel

Textbook: Introduction to Fluid Mechanics by Philip J. Pritchard. John Wiley & Sons, 8th Edition, ISBN ,

NUMERICAL ANALYSIS OF THE EFFECTS OF WIND ON BUILDING STRUCTURES

Optimize Pipeline Hydraulics with Multiphase Flow Modeling

Tadahiro Yasuda. Introduction. Overview of Criterion D200. Feature Article

1. A belt pulley is 3 ft. in diameter and rotates at 250 rpm. The belt which is 5 ins. wide makes an angle of contact of 190 over the pulley.

ORIFICE PLATES. CONCENTRIC BORE: For standard fluid conditions an Orifice Plate would have a centrally located orifice bore.

ENHANCEMENTS AND NEW FUNCTIONS IN CONVAL 9

ME 305 Fluid Mechanics I. Part 8 Viscous Flow in Pipes and Ducts

Piping Hydraulic Line Design and Sizing Software KLM Technology Group

Theory, Application, and Sizing of Air Valves

Manufacturing Equipment Modeling

International Journal of Latest Research in Science and Technology Volume 4, Issue 2: Page No , March-April 2015

Backwater Rise and Drag Characteristics of Bridge Piers under Subcritical

Aeration Air & Digester Gas Flow Metering Using Thermal Mass Technology. HWEA 2011 Conference Craig S. Johnson

Testing methods applicable to refrigeration components and systems

Flow Measurement Options for Pipeline and Open Channel Flow

Open Channel Flow Measurement Weirs and Flumes

INLET AND EXAUST NOZZLES Chap. 10 AIAA AIRCRAFT ENGINE DESIGN R01-07/11/2011

Compressible Fluids. Faith A. Morrison Associate Professor of Chemical Engineering Michigan Technological University November 4, 2004

No. Name Description Main input Data Main Output Data. cooling duty, process in/out temperature, inlet air temperature

PSAC/SAIT Well Testing Training Program Learning Outcomes/Objectives Level B

ME 239: Rocket Propulsion. Over- and Under-expanded Nozzles and Nozzle Configurations. J. M. Meyers, PhD

CE 6303 MECHANICS OF FLUIDS L T P C QUESTION BANK PART - A

Routinely surveying tower overhead vacuum systems can

Thermal Dispersion Mass Flow

Lecture 24 Flumes & Channel Transitions. I. General Characteristics of Flumes. Flumes are often used:

Dynamic Process Modeling. Process Dynamics and Control

Design of heat exchangers

PIPING WORKBOOK. Solving Piping and Header Networks Using CHEMCAD. Version 6.2

Pipe Flow-Friction Factor Calculations with Excel

The Versatile Differential Pressure Transmitter. By David Gunn Honeywell Process Solutions

Optimum fin spacing for fan-cooled heat sinks

Transcription:

Modeling Choked Flow Through an Orifice Summary Periodically AFT Arrow users pose the question of what CdA value to use for modeling choked flow through an orifice. This paper reviews the subject to provide guidance in this area. As will be seen, there is not one answer. Discussion AFT Arrow provides several options in modeling an orifice, perhaps the two most commonly used being the Sharp-Edged and Cd (discharge coefficient) orifice models. The Sharp-Edge model uses Idelchik's 'sharp-edged orifice' equation found on page 221 of reference (1); k = p F = + F 1 1 1.77 1 2 ρw1 / 2 F1 F1 F.5 2 F 2 Where: w 1 = velocity in upstream pipe F, F1 = orifice and upstream areas, respectively Idelchik lists this equation as valid for an orifice thickness to hydraulic diameter ratio of to.15. Notably, the above relationship is for incompressible flow 1 (as are all resistance coefficients in Idelchik). When a Cd is specified, AFT Arrow uses the following equation from page 339 of reference (9). 1 Ref: Idelchik Page 4 footnote.

Modeling Compressible Flow through an Orifice 2 AFT Arrow evaluates sonic flow if a C d A is specified based on equation 3.23 of Saad;. m = A p T γ M R γ 1 1+ M 2 2 ( γ + 1) 2( γ 1) For choked flow, M = 1 and A = C d A (the same relationship is used for endpoint and expansion choking with A equaling the physical area of the pipe discharge at the endpoint or entering the expansion). Crane For high Reynolds numbers from about 1 5 and higher, Crane, page A-2, indicates an essentially constant flow coefficient for sharp edged orifices that depends only on the orifice to pipe diameter ratio. C d is related to the flow coefficient C by the following: 4 C d = C 1 β Where β = orifice diameter / upstream pipe diameter. While C increases with increasing β to a value of ~.74 for β =.75, because of the above relationship C d is ~.6 irrespective of β and this value is often used in calculating C d A by multiplying the physical orifice area times.6. In a related discussion on page 2-14 of ref. (3), the following equation is provided by Crane for the flow of gases and vapors: Where q is volumetric flow. This is the same form of equation used for incompressible flow with the addition of the expansion factor Y, which relates the density of the fluid at the orifice to the upstream density. Further, Crane states; q = YCA 2g(144) P ρ "When the absolute inlet pressure is greater than this amount, flow through nozzles should be calculated as outlined on the following page."

Modeling Compressible Flow through an Orifice 3 which goes on to state; "A smoothly convergent nozzle has the property of being able to deliver a compressible fluid up to the velocity of sound in its minimum cross section or throat." Values of Y as a function of the pressure drop ratio (defined as the pressure differential divided by the upstream pressure) and the expansion coefficient k, are provided on page A-21. For nozzles, Y has a minimum value corresponding to choked flow. No such minimum value of Y is provided for a square edge orifice indicating the limitations in using the Crane method to evaluate choked flow through an orifice. Cunningham In his paper Orifice Meters With Supercritical Compressible Flow, ref. (4), Cunningham states; "For a well-formed convergent nozzle, the (experimental) maximum flow ratio is essentially identical with the (theoretical) critical-pressure ratio. Evidently the occurrence of sonic velocity at the throat of the nozzle prevents flow response to changes in the discharge pressure. Contrary to the behavior of the convergent nozzle, the squareedged orifice does not exhibit a maximum flow ratio. Rather, experiment shows that the flow rate (for constant upstream conditions) continues to increase at all pressure ratios between the critical and zero; this range is defined as the 'supercritical" range of ratios" Cunningham goes on to provide a brief description of a previous investigation by Stanton, explaining that shock disturbances were evident at all orifice pressure ratios below critical, but that the location of the critical pressure was downstream of the orifice and moves toward the orifice as the discharge pressure is lowered. The bulk of Cunningham's paper reports on the empirically determined expansion coefficient to be used in the "ASME Equation"; G = KYA 2 gc ρ 1 p

Modeling Compressible Flow through an Orifice 4 Two sets of equations for the expansion coefficient are developed. One for "flange taps" and another for "pipe taps". Each set consists of two equations, one for high pressure ratios and the other for lower pressure ratios as follows (r = P 2 /P 1 or P downstream /P upstream ); Pipe taps - 2 5 13 1 r >=.77 1 (.333 + 1.145( β +.7β + 12β ) κ r <.77 Y.364(. 77 r) Flange taps -.77 4 1..41+.35β 1 r r >=.63 ( ) κ Y r r <.63.63.351(. 63 ) r Driskell In a discussion of flow through nozzles, restrictions and enlargements at www.isa.org, ref. (5), reference is made to L.R. Driskell as follows; "Driskell repeated his stand in a later publication, Control-Valve Selection and Sizing. He described choked flow as being that condition where flow cannot be increased by lowering downstream pressure. He further described the vena contracta as migrating upstream to coincide with the orifice when the flow is completely 'choked' (meaning it has reached its maximum steady-state value of flow)." This appears to be both similar to and contradict Cunningham, for while a description of a moving vena contracta based on the downstream pressure is provided, it also states the vena contracta 'coincides' with the orifice when it is 'choked'. Contrary to this, Stanton's data (included in Cunningham's paper), clearly shows that while the vena contracta approaches the orifice with decreasing downstream pressure it never reaches it. Further, if the vena contracta 'coincides' with the orifice as Driskell asserts, this would imply a C d equal to 1., a seeming contradiction to accepted values of C d less than 1. for 'well formed' nozzles.

Modeling Compressible Flow through an Orifice 5 ENGSoft That an orifice does not exhibit a maximum flow at a critical pressure ratio is reflected in other sources as well. For example, ENGSoft Inc. which states on their website www.engsoft.co.kr, ref. (6); Ward-Smith "In case of orifice, actually there is no critical pressure. The mass flow rate increases as much as the discharge pressure is decreased till zero absolute pressure." Optimal Systems, www.optimal-systems.demon.co.uk, ref. (7), provides a description of a series of experiments conducted by Ward-Smith wherein it is stated; In summary, the principal parameter affecting sonic discharge coefficient is the aspect ratio of the orifice, expressed as the ratio of the plate thickness to the orifice diameter (t/d)... Once sonic velocity has been achieved, further reduction of the downstream pressure cannot further increase the velocity through the vena contracta, but if the orifice plate is thin, it can increase the vena contracta's size. Further reductions in downstream pressure cause the vena contracta to move upstream and to consequently increase in area. Ultimately, at high pressure ratios, the vena contracta can reach the upstream edge of the orifice, when its area would equal that of the orifice and the discharge coefficient would be unity." Like Driskell, the vena contracta is described as reaching the orifice at 'high' pressure ratios (indeed, the upstream edge of the orifice) yielding a discharge coefficient of 1.. Ward-Smith is further quoted on this subject in http://www.engtips.com/viewthread.cfm?qid=1658&page=1 as providing the following choked flow Cd values: sharp edge, t/d=, Cd = 1. thin plate (<t/d<1)cd varies smoothly from 1 to.81 as function of t/d. thick plate ( 1<t/d<7) Cd =.81 constant very thick plate (t/d > 7) Cd less than.81 per Fanno friction Where t/d equals the ratio of the orifice thickness to its diameter.

Modeling Compressible Flow through an Orifice 6 ASME Finally, we have the current ASME standard MFC-3M-1989. It is worthwhile to review the scope of application of this standard as it pertains to this discussion; Applies only to pressure difference devices in which the flow remains turbulent and subsonic. Within the pipe size and Reynolds number limits specified. Orifice to upstream pipe diameter ratio of.2 >.7. Ratio of downstream to upstream pressure >=.75. Of particular note, the ASME standard is limited to pressure ratios greater than the critical pressure ratio and does not cover choked flow through an orifice. Mass flow - q m π = 2 2 pρ f 1 CY1d 4 4 1 β Equations for C - For D and D/2 taps (upstream ID >= 2.3 in.) 4 1 3 2.5. 75 ( 1 β ).1584β + 91.71β R 2.1 8 4 C =.5959 +.312β.184β +.39β D For flange taps upstream ID >= 2.3 in. 4 1 1 3 2.5. 75 ( 1 β ).337D β + 91.71β R 2.1 8 1 4 C =.5959 +.312β.184β +.9D β D 2 in. < upstream ID < 2.3 in. 4 1 1 3 2.5. 75 ( 1 β ).337D β + 91.71β R 2.1 8 1 4 C =.5959 +.312β.184β +.39D β D Expansion factor, Y - 4 (.41+.35β ) p ( κ ) Y1 = 1 / p1 Note that this is the same equation as presented by Cunningham for pipe taps with a pressure ratio >=.63.

Modeling Compressible Flow through an Orifice 7 Comparative Results Runs were made in AFT Arrow along with corresponding calculations using ASME MFC-3 (ignoring the pressure ratio limitation) and Cunningham. AFT Standard air is used as the fluid with the orifice upstream pressure constant at 5 psia @ 7F and downstream pressure varying from 45 psia to 5 psia. Inlet and outlet pipes have a 4 ID> Comparison was made to both AFT Arrow s Sharp-Edged and Cd orifice models. The following notes apply to each modeling/calculation method: AFT Arrow Sharp-Edged varying CdA Orifice specified with a 1 diameter with CdA calculated over a range of Cd values from.6 to 1. x the orifice area. AFT Arrow Used Specified Cd Variable Cd value.6 (very nearly equal to the ASME value for C of.5979865) to.9, CdA calculated as Cd x orifice area. AFT Arrow Used Specified Cd Variable Cd value.6 to.9, no CdA specified. ASME MFC-3 - For Δp/p >.4, which includes all of the cases considered here, an arithmetic average k should be used, which was calculated using AFT Arrow's values for upstream and downstream gamma (in all cases, gamma average is equal to or very nearly 1.4). Expansion factor is calculated from the MFC-3 equation for Y, though this standard is limited to pressure ratios >=.75; i.e. a downstream pressure of 37.5psia. Cunningham Uses Cunningham s value of.668 for K, the orifice discharge coefficient, applicable to pipe taps and a beta up to.4. As they both use very similar discharge coefficient values, C =.5979865 for ASME and K =.668 for Cunningham, flows differ by the value of Y used, which compares as follows.

Modeling Compressible Flow through an Orifice 8 Expansion Factor Comparison 1..95.9.85.8.75.7 Expansion Factor - Y ASME Cunningham.65 1.9.8.7.6.5.4.3.2.1.6 Pressure Ratio - P2/P1 The following tables show flow in lbm/sec over a range of orifice pressure ratios for each of the above listed AFT Arrow orifice models and as calculated using ASME and Cunningham. User Specified Cd =.6 / Various CdA (Cd x A) P2/P1 ASME MFC-3M Cunningham Cd =.6 Cd =.7 Cd =.8 Cd =.9 Cd = 1..9.34.35.34.39.45.5.56.8.47.48.45.52.59.67.74.77.5.51.47.55.62.7.78.7.56.57.51.59.68.76.85.6.63.63.54.63.72.81.9.5.68.67.54.64.73.82.91.4.72.7.54.64.73.82.91.3.75.73.54.64.73.82.91.2.77.74.54.64.73.82.91.1.78.74.54.64.73.82.91

Modeling Compressible Flow through an Orifice 9 User Specified Cd Variable / CdA = Cd x Orifice Area) 1..9.8.7 ASME MFC-3M Cunningham.6.5.4 Flow - lbm/sec Cd =.6 Cd =.7 Cd =.8.3.2 1.9.8.7.6.5.4.3.2 Cd =.9 Cd = 1..1.1. P2/P1 Sharp-Edged - Cd for CdA P2/P1 ASME MFC-3M Cunningham Cd =.6 Cd =.7 Cd =.8 Cd =.9 Cd = 1..9.34.35.36.36.36.36.36.8.47.48.51.51.51.52.52.77.5.51.54.55.55.55.55.7.56.57.54.63.63.63.63.6.63.63.54.64.73.73.73.5.68.67.54.64.73.81.82.4.72.7.54.64.73.82.89.3.75.73.54.64.73.82.91.2.77.74.54.64.73.82.91.1.78.74.54.64.73.82.91

Modeling Compressible Flow through an Orifice 1 Sharp-Edged Orifice Model - Various CdA = Cd x Orifice Area) 1..9.8.7 ASME MFC-3M Cunningham.6.5.4 Flow - lbm/sec Cd =.6 Cd =.7 Cd =.8.3.2 1.9.8.7.6.5.4.3.2 Cd =.9 Cd = 1..1.1. P2/P1 User Specified Cd - No CdA P2/P1 ASME MFC-3M Cunningham Cd =.6 Cd =.7 Cd =.8 Cd =.9 Cd = 1..9.34.35.34.39.45.5.56.8.47.48.45.52.59.67.74.77.5.51.47.55.62.7.78.7.56.57.51.59.68.76.85.6.63.63.54.63.72.81.9.5.68.67 7.69 7.69 7.69 7.69 7.69.4.72.7 7.69 7.69 7.69 7.69 7.69.3.75.73 7.68 7.68 7.68 7.68 7.69.2.77.74 7.69 7.69 7.69 7.69 7.69.1.78.74 7.68 7.68 7.68 7.68 7.69

Modeling Compressible Flow through an Orifice 11 User Specified Cd Variable - No CdA 9. 8. 7. ASME MFC-3M Cunningham Cd =.6 Cd =.7 Cd =.8 Cd =.9 Cd = 1. 6. 5. 4. 3. 2. Flow - lbm/sec 1. 1.9.8.7.6.5.4.3.2.1. P2/P1 Observations & Conclusions AFT Arrow does not currently use a compressible method to model subsonic flow in an orifice (since no recognized standard covers the full range of pressure ratios). While it faithfully reproduces Idelchik's loss values and the Cd method, both are incompressible methods. ASME and Cunningham yield very similar results down to a pressure ratio of about.4, with ASME yielding an increasingly greater flow as pressure ratio progresses to lower values due mainly to the difference in the value of the expansion factor. Using the ASME C value of ~.6 as the C d in AFT Arrow produces a flow rate similar to ASME and Cunningham at high pressure ratios. As pressure ratio is reduced the value of Cd must be increased to yield a comparable flow rate. Flow with the user specified Cd is limited at sufficiently low pressure ratios by choked flow, which is determined by the CdA. For example, at a pressure ratio of.6 the flow using the user specified Cd of.7 (and corresponding CdA of.7 x orifice area) matches that of ASME and Cunningham while at a pressure ratio of.1 a Cd of approximately.8 to.9 is needed to match.

Modeling Compressible Flow through an Orifice 12 Using AFT Arrow s sharp-edged orifice, which implements Idelchik s equation, flow match ASME and Cunningham at high pressure ratios, but deviates in sub-sonic flow at lower pressure ratios with the sharp-edged orifice model yielding an increasingly higher flow rate. The sharp-edge orifice model flow is limited by choking, the flow rate then a function of the CdA value specified. At a pressure ratio of.6, for example, a CdA =.7 x orifice area closely matches the ASME and Cunningham flow rates while at a pressure ratio of.1 a CdA of.8 to.9 is needed, just as with the user specified Cd orifice model. As to what the various references reviewed say about choked flow in an orifice, they are inconclusive. Cunningham, and by reference Stanton, clearly indicate a flow limit does not occur at the critical pressure ratio. Notably, these are substantiated by empirical data. Driskell says the vena contracta coincides with the orifice throat at sufficiently high pressure ratios, though what pressure ratio this corresponds to is not clear. Ward-Smith describes sonic velocity occurring at the vena contracta, with further downstream pressure reduction causing the vena contracta to move upstream, eventually coinciding with the orifice throat and yielding a C d of 1.. Referring to either of the curves above with a CdA, one does see flow with a CdA calculated from a Cd of 1. substantially above ASME and Cunningham. There is a similarity between Driskell,Ward-Smith, Cunningham and Stanton in their description of the vena contracta occurring downstream of the orifice and moving toward the orifice as downstream pressure is reduced. Differences occur in the maximum value of C d and/or value of Y. Ward-Smith indicates a C d of 1. (for a thin orifice), but as noted above, using this in AFT Arrow produces a choked flow well above ASME and Cunningham. The accuracy of C/C d calculated using ASME below pressure ratios of.75 is unknown. To answer the question at the beginning of this paper, what CdA value to use for modeling choked flow through an orifice, that depends on the goal. If the goal is to insure a minimum flow rate, then one would want to use a low CdA value. On the other hand, if the goal is to identify a maximum possible flow, then a high CdA value would be used. From the comparative results presented above, low and high would correspond to a CdA calculated as the orifice area multiplied by a Cd value of.6 to 1.. Note that these results represent only one possible fluid and upstream

Modeling Compressible Flow through an Orifice 13 conditions. For a better approximation one may calculate the flow using the ASME of Cunningham equations and iteratively determine an appropriate Cd value for the specific conditions. Further, if one needs to more precisely predict choked flow, then the system design should incorporate a nozzle in lieu of an orifice. Properly designed nozzles achieve a Cd under subsonic and choked flow conditions approaching one, that is, they approach the conditions of end point choking as one would see at the discharge from a pipe. Finally, the last graph above is presented to illustrate the necessity to specify CdA values consistent with the Cd value with this orifice model. In this graph various Cd values are used but no CdA is specified causing a discontinuous transition from subsonic to choked flow as AFT Arrow moves from the subsonic calculation to the sonic. References 1) Handbook of Hydraulic Resistance 3rd Edition, I.E. Idelchik, 1994 CRC Press, Inc. 2) Compressible Fluid Flow Second Edition, Michel A. Saad, 1993, 1985 Prentice-Hall, Inc. 3) Flow of Fluids, Crane Technical Paper No. 41, 1988 Crane Co. (Twenty Fifth Printing - 1991) 4) Orifice Meters With Supercritical Compressible Flow, R.G. Cunningham, Transactions of the ASME, July, 1951. 5) IDEAL GAS FLOW THROUGH NOZZLES, RESTRICTIONS AND ENLARGEMENTS, http://www.isa.org/books/mulley_papers/nozzles.html 6) Compressible Flow Analysis of Steam, http://www.engsoft.co.kr/download_e/steam_flow_e.htm#4.%2compressible%2flow%2ana lysis%2of%2ideal%2gas, ENGSoft Inc. 7) Sonic flow through orifices, nozzles and venturis, http://www.optimal-systems.demon.co.uk/floworifice.htm, 1999 Optimal Systems Limited And by reference from the above - "Critical flowmetering: The characteristics of cylindrical nozzles with sharp upstream edges", Ward-Smith, A.J., Int. J. Heat & Fluid Flow, vol 1, No 3, 1979

Modeling Compressible Flow through an Orifice 14 8) Measurement of Fluid Flow in Pipes Using Orifice, Nozzle and Venturi, ASME MFC-3M-1989, 199 by The American Society Of Mechanical Engineers. 9) AFT Arrow User s Guide, AFT Arrow version 4. Compressible Pipe Flow Modeling, 26 Applied Flow Technology Corporation.