Omron & Westermo Modems

Similar documents
Sending SMS Messages and s

FINS Gateway For OMRON PLCs

ACU-1000 Manual Addendum Replacement of CPM-2 with CPM-4

Connecting the DG-102S VoIP Gateway to your network

How to setup a serial Bluetooth adapter Master Guide

To perform Ethernet setup and communication verification, first perform RS232 setup and communication verification:

Programming and Using the Courier V.Everything Modem for Remote Operation of DDF6000

Accessing Diagnostics using a Dialup Modem

USER GUIDE. Ethernet Configuration Guide (Lantronix) P/N: Rev 6

Application Note: Connecting to a 2500 Series Processor using PLC Workshop

TCP/IP MODULE CA-ETHR-A INSTALLATION MANUAL

Andover Continuum Remote Communication Configuration Guide

Configuring the Siemens TC35 modems for use with the MI2292

SETTING UP A REMOTE MODEM CONNECTION Application Note 27

IP SERIAL DEVICE SERVER

Communications Instructions for DOOSAN, FANUC Controls

Keep it Simple Timing

DUKANE Intelligent Assembly Solutions

Connecting and Setting Up Your Laptop Computer

Quick Note 32. Using Digi RealPort with a Digi TransPort Router. UK Support September 2012

Modbus and ION Technology

1. Make sure that no client accounts are open. 2. Click on Setup, then click Modem. The Modem Setup window will appear.

Hypercom Key Loading and Management (HKLM) RS232 PPP Key Injection PC Setup Guide

ADDENDUM - Bluetooth interface Option Instructions for using Extech Printer with a Bluetooth device

PLC training panel (Twido version)

Troubleshooting Sprint Mobile Broadband USB Modem by Novatel Wireless TM (Ovation TM U727)

DIRECT INTERNET DATA. User s Guide

TSX ETZ Configuration of your computer for TSX ETZ direct connection by serial link. Eng V1.0

Guide to Installing BBL Crystal MIND on Windows 7

Using HyperTerminal with Agilent General Purpose Instruments

About This Guide SolarEdge Configuration Tool Software Guide. About This Guide

Palomar College Dial-up Remote Access

Enabling Internet Connection Sharing on Windows Enabling ICS On Windows XP As The Host 4 Enabling ICS On Windows XP As The Client 11

PC Program User s Guide ( ) 1. Connecting the PC. 2. Installation and Start-up. 3. Programming

FLASH PROCEDURE for GSM BENTEL and DSC cards

Ethernet Interface Manual Thermal / Label Printer. Rev Metapace T-1. Metapace T-2 Metapace L-1 Metapace L-2

Metasys System Direct Connection and Dial-Up Connection Application Note

enervista UR Setup Software Quick Connect Instructions:

How To Connect A Directsofl To A Powerpoint With An Acd With An Ctel With An Dm-Tel Modem On A Pc Or Ipad Or Ipa (Powerpoint) With A Powerline 2 (Powerline

DIAL-UP DATA. User s Guide

Installing PowerLink on Windows 7 64-bit

Dial-Up / Leased-Line Modem. User Manual. AGM Electronics, Inc Dial-Up / Leased-Line Modem, Series ( ) Manual Rev A + - DLM CTS RTS DTR DSR

POS Integration. Prepared by: Binh Nguyen

Global Monitoring + Support

ADSL Router Quick Installation Guide Revised, edited and illustrated by Neo

Iridium Extreme TM Satellite Phone. Data Services Manual

64-Bit Compatibility with Micromeritics Applications

IP Link Device Interface Communication Sheet

Cisco - Configure the 1721 Router for VLANs Using a Switch Module (WIC-4ESW)

IGSS. Interactive Graphical SCADA System. Quick Start Guide

INSTALLATION AND OPERATION MANUAL CNFE2DOE TERMINAL SERVER

User Manual. Thermo Scientific Orion

Maintaining the Content Server

Important Notes for WinConnect Server VS Software Installation:

BASLER ACE QUICK INSTALLATION GUIDE

SECURITY SYSTEM MANAGEMENT SOFTWARE FOR WINDOWS. Quick Start Instructions

Application Note Connect to a Rockwell PLC over Netbiter Remote Access

DSX-HSCS Hot Swap Comm Server

User s Manual for Fingerprint Door Control Software

MODEM AND DIAL-UP. Installation/Configuration (Windows 95/98/Me/NT/2000/XP)

How To Set Up A Modbus Cda On A Pc Or Maca (Powerline) With A Powerline (Powergen) And A Powergen (Powerbee) (Powernet) (Operating System) (Control Microsci

Configuring the Switch with the CLI Setup Program

Voice Over Internet Protocol (VoIP) Configuration

LS-101 LAN to Serial Device server. User s Manual

Important Notes for WinConnect Server ES Software Installation:

Technical Note #14. Phone Modem Device Support. GE ED&C Home Search ED&C GE ED&C Power Management Home GE ED&C PMCS Home

WA Manager Alarming System Management Software Windows 98, NT, XP, 2000 User Guide

SHDSL LAN EXTENDER H301A. User Manual

Schneider OS-Loader usage via Ethernet or USB.

Global Water Instrumentation, Inc.

Different Ways of Connecting to. 3DLevelScanner II. A.P.M Automation Solutions LTD. Version 3.0

Current Cost Data Cable User Guide. Installing and configuring the data cable

Job Aid: Creating Additional Remote Access Logins

Plena Voice Alarm System Firmware update

Internet Guide. Prepared for 55 John Street

WinPFT File Transfer Utility (Catalog No ND7)

INSTALLING AND USING ENTEL PROGRAMMER IN WINDOWS 7 Technical Support Bulletin

ENET-710. ENET Ethernet Module ENET-710 JAN / 06 FOUNDATION

Setting up VPN Access for Remote Diagnostics Support

Omron I/O Driver (Series 2) Programmable Serial Interface Card

Remote Access for Schneider Electric Modicon Micro & Premium Series PLCs

32 Transferring Projects and Data

SUDT AccessPort TM Advanced Terminal / Monitor / Debugger Version 1.37 User Manual

Chapter7 Setting the Receiving PC for Direct Upload. Setting the Receiving PC for Direct Upload For Windows For Macintosh...

Guide to Setting up Internet Connection Sharing for Windows

F2103 GPRS DTU USER MANUAL

Application Notes for Configuring NMS Adaptive Desktop SMS with Avaya IP Office R8.0 using Avaya IP Office TAPI Service Provider - Issue 1.

T3 Mux M13 Multiplexer

Bluetooth HC-06 with serial port module Easy guide

Instructions on How to Use HyperTerminal to Test Serial Ports ...

1. Hardware Installation

IP Link Device Interface Communication Sheet

OfficeServ Link. User Guide. Version 2.1 June 2005

ReadMe File. Installing the Unified Messaging Application for

PARTNER ACS R4.0 Remote Administration R4.0. Getting Started

AXIS 205 Network Camera Quick Installation Guide

Configuring the Beckhoff BK9000 Network Parameters

Tutorial: Configuring GOOSE in MiCOM S1 Studio 1. Requirements

Technical Notes TN 1 - ETG FactoryCast Gateway TSX ETG 3021 / 3022 modules. How to Setup a GPRS Connection?

Setting Up the ZigBee Ethernet Gateway

Transcription:

Application Note Remote Access Solutions AN-0117-ENG rev4.1 Page 1

Contents Introduction... 3 Setup of RS232 Ports on Omron PLC s...4 Connection Flowchart..5 Cable Pin Out Connections 6 Cable Pin Outs for PLCs.7 Setup of PLCin CX Programmer for Dialup. 8 Omron Network Configuration Tool...9 Omron CX Modem Support Tool...10 Omron CX Modem Support Tool...11 TDTool2 and DIP Switch settings..12 Using GDTool with the GDW11. 13 Increasing Connection Speed 14 Using Toolbus Protocol 15 Additional RS232 Ports and Cables..16 Alternative Westermo to Omron Connections. 17 ED20 and DDW to Omron Ethernet PLC s.. 18 AN-0117-ENG rev4.1 Page 2

Introduction There are many PLC applications that require a Remote connection, from Monitoring data, SCADA control to PLC programming and register data adjustment. All of these applications require a reliable connection in a variety of industrial conditions. Westermo modems provide a reliable connection for these harsh industrial connections which can save an Engineer a costly trip to site or provide a communications link to a hazardous area. This Application Note provides detailed information on connecting Westermo Modems and the range of PLC s available from Omron. The following configurations have been tested and approved by both Westermo and Omron Technical Support. The equipment and versions required are as follows: 1x Laptop or Desktop PC with Modem and the following software pre-loaded - Omron CX Programmer V5.0 or above - Omron CX Server V2.2 or above - Omron Modem Support tool V1.0.0.4 or above - TDTool2, GDTool or Windows Hyperterminal or similar Terminal package 1x Modem to PC lead if external PC modem used - For 9 pin D type on Modem use Westermo cable Article number 9450-0003 - For 25 pin D type on Modem use Westermo cable Article number 9450-0002 2x Analogue telephone lines or a Westermo Analogue Line simulator, Article number 9045-001 1x Omron PLC e.g. CPM2* Series / CQM1 Series / CJ Series / CS series / C200H Series 1x Omron PLC Programming Cable e.g. CS1W-CN226 for a CJ PLC - available from Omron 1x Westermo Modem to Omron 70cm cable. Westermo Article numbers shown below - 9450-0322 for TDW33, TD36, TD36/485, TD-35, GDW11 and other older Westermo Modems such a TD-33 and GD-01 (2m cable also available) - 9450-0312 for a TD32B Modem (2m version also available) 1x Westermo Modem e.g. TDW33, TD-36, TD36/485, GDW11 or an older Westermo Modem such as a TD32B or TD-35 AN-0117-ENG rev4.1 Page 3

Section 1 - Setup of RS232 Ports on Omron PLCs To ensure reliable and efficient communications we recommend changing the default settings of the PLC s RS232 port to the following: 9600, 8 Data bits, No parity and 1 Stop bit using SYSMAC WAY as the Protocol These settings ensure the best compatibility with a wide range of Modems such as built in PC modems which are normally setup for basic Internet access rather than PLC protocols. The RS232 port that will be used for the Modem connection will need to be setup prior to the Modem setup and testing. This requires that the PLC is placed in program mode and the new port settings will have to be Transferred to the PLC. ALWAYS ENSURE THAT THE PLANT BEING CONTROLLED IS SAFE BEFORE CHANGING THE PLC PROGRAM STATE. Open the PLC Project in CX Programmer and Select the Settings menu for the PLC that will be used with the Modem Connection Select the Host Link Tab and then Change settings to: Custom, 9600,81N, Hostlink. NOTE: When using an RS232 port on a Serial Communications module, use the IO table to setup and transfer the same custom port settings and ensure that the correct Unit Number is selected for the module being used, when making a connection to the PLC. AN-0117-ENG rev4.1 Page 4

Section 1 - Connecting the Westermo Modems to the Omron PLC Start Configure PLC and Network Configuration/CX Modem Support Tool as shown in Section 2. Download program/ port settings to PLC as shown in Section 1. Is the Remote Modem a TD-36, TD-36/485 or TD-35? Yes No Is the Remote Modem a TDW33 or GDW11? Yes No Please refer to Modem Manufacturers documentation Setup DIP switches as shown in Appendix 1 Using CX Modem Support Tool? Yes No Connect to PC using Modem cable and Configure using TDTool2, GDTool or Hyperterminal as shown in Appendix 1 Connect to PC using Modem cable and download Modem Command String using CX Modem Support Tool as shown in Section 2 If an External PC Modem is used, connect PC to the Modem using a Modem cable Are analogue lines being used? No Is an analogue line simulator available? No Make provision for analogue phone lines before restarting connection process Yes Yes Connect Modems to analogue lines using cables supplied with Modems Connect Modems to analogue line simulator using cables supplied with Modems Ensure that the simulator has power applied Connect Remote Westermo Modem to Omron PLC using pre made cable or with pin outs shown in this document End of Connection Process AN-0117-ENG rev4.1 Page 5

Application Note Section 2 - Cable Pin Out Connections Note: Omron PLC The Host Link Port control switch on the PLC should be set to OFF to use the user defined port parameters. This is usually DIP switch 5 or 6 on the processor switch block (depending on PLC model), except the CPM2A which has just one dedicated Port Settings Switch. Please see the Omron PLC manual for details of DIP switch settings. TD-36 Any Omron PLC 9 Way D Sub (Male) 9 Way Screw terminals 2 3 7 8 5 1 3 2 4 5 9 Power Run ERR/ALM COM1 COM2 SYSMAC CQM1 9 Way D Sub (Male) IDW-90, TDW-33 or GDW-11 Any Omron PLC 9 Way D Sub (Male) 5 Way Screw terminals 2 3 2 1 5 5 3 2 4 5 9 Power Run ERR/ALM COM1 COM2 SYSMAC CQM1 9 Way D Sub (Male) Please Note: Ready made cables are available from Westermo. The Article number for 70 cm long cables are as follows: 9450-0322 (MC9-OMHL-70cm) for TDW33, TD-36, TD-36/485, IDW-90 & GDW-11 (2m version cable also available) AN-0117-ENG rev4.1 Page 6

Double Click on PLC in CX Programmer Project then Select the PLC type 1 Section 2 - Set up of PLC in CX Programmer for Modem Dialup Connection Then select Settings Select preferred bus type to be SYSMAC WAY 2 Once all of the Phone Numbers and Codes have been entered, select Configure Select the Modem at the PC end to be used Enter the telephone number of the Westermo Modem at the Remote PLC Ensure that the correct country and area code is entered 3 4 Note:For Outside Line access e.g. 9 use the Dialling Rules setup under Windows Phone and Modem Options in the Windows Control Panel Check that the Modems Port speed is set to Default 115200 then select Advanced Tab On Advanced Tab, check that ths Hardware Settings are set to the Default of 8 Data, None Parity and 1 Stop Bit then Click on OK button AN-0117-ENG rev4.1 Page 7

Section 2 - Network Configuration Tool The Network Configuration Tool is used to configure and test the network connections on the PLC s within a CX Programmer/Server Project. It is also used to create the Project file that the Modem Support Tool can access to setup and test the Modems and the link. In CX Programmer, Select the PLC that will use a Modem connection, then open the Network Configuration Tool under Tools on the Main Menu In the Network Configuration Tool, select Project then Save As. Enter a filename.cdm and make a note of the path to the file as this will be required in the Modem Support Tool. AN-0117-ENG rev4.1 Page 8

Section 2 - Omron CX Modem Support Tool Information The Omron CX Modem Support Tool is used to configure and test the PLC Modem link that has been configured in a CX Programmer / Server Project. The software is available as a free download for Registered users of CX Programmer V5 and above from the Omron website. The current release of the Tool (V1.0.0.4) has an incorrect setting on each of the Modems. Updated Modem Command Strings are available at either www.omron.co.uk or at www.westermo.co.uk and can then be saved locally on the PC to C:\Program Files\Omron\ Modem Support Tool\Modems. The Modem Support Tool is located in the Omron Programs folder on the Windows START menu. Once the Tool is running, Select Project then Open and locate the filename.cdm Project file that was created with the Network Configuration Tool Select the PLC from the Project that will be connecting via the modem link. The PC modem and PLC should now have some details underneath their icons. To test the Modem at the PC end, select Device, Perform test then Test local modem. The test will run and then should display Test Passed or will open a help file on a failure. AN-0117-ENG rev4.1 Page 9

Section 2 - Omron CX Modem Support Tool To setup the Remote Modem, connect the PC directly to the Modem using the Modem Cable. Select Remote Modem under Project Devices then Select Modem, Download Settings from the Main Menu. Select Custom, Com1 (change if connected to another com port on the PC), 9600, 8, None, 1. Then click on Next. Select the Modem type from the list. Then click on Download. It is also possible to add a new modem and edit/view the existing Modem command strings here. The Modem command string to be sent to the Modem will now be displayed followed by Download complete. Click on Close to finish. Now reconnect the Omron PLC cable to this Modem AN-0117-ENG rev4.1 Page 10

Section 3- Testing of the Modem Connection to the PLC 1. Using CX Modem Support Tool To test the Modem link to the PLC using the CX Modem Support Tool select Device then Open on the Main Menu or use the button on the Toolbar. To display Modem Connection Diagnostics, Enable them from under View on the Main Menu. On a good connection, the diagram will show a highlighted path to each device and the Diagnostics will show Connected. On a failure to connect the diagram will show which device the connection path failed on and provide a choice for displaying a help file. To close the connection, select Device then Disconnect and the Modems will hang up 2. Using CX Progammer Now that the Communications link has been proven, it is now possible to select Work Online from under PLC on the Main Menu in CX Programmer or from the icon on the Toolbar after first selecting the PLC that has been configured for the Modem link within the Project. The Modems will now dial and CX Programmer will go online to the PLC. To shutdown the connection, just re-select Work Online using the same method used to go online to the PLC. This will disconnect the Modem link as well. AN-0117-ENG rev4.1 Page 11

Appendix 1 - Switch Settings and TDTool2 It is also possible to use the DIP Switches to configure the Westermo Modems, TD-36, TD-36/485 and TD-35, instead of using the CX Modem Support Tool or a Terminal package, such as Hyperterminal, to enter the Modem Command Strings. The DIP Switch settings shown below are the recommended settings for these Modems. SW1 ON 1 2 3 4 5 6 7 8 TD-35 SW2 ON 1 2 3 4 5 6 7 8 TD-36 and TD36/485 SW 1 SW 2 ON ON ON 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 SW 5 SW3 ON 1 2 3 4 5 6 7 8 OFF for a modem connected to a PC SW4 ON 1 2 3 4 5 6 7 8 SW 4 ON 1 2 3 4 5 6 7 8 SW 3 ON 1 2 3 4 5 6 7 8 OFF for a modem connected to a PC TDW33 The TDW33 is configured using TDTool 2 which is delivered with the modem. The Windows based tool allows for simple configuration of the modem using pulldown options for the AT command strings. TDTool 2 can also be used to configure the TD36 and TD36/485 modems. Once the configuration has been entered on each screen select WRITE to store the new profile in the modem. 1) Connect Using Auto baud and a MC9/9 cable from PC 3) On Serial Tab, Set to 9600, 8, N, 1 and also set the commands Q1E0&C1&K0&D0 at the PLC modem and Q0E1&C1&K0&D2 at the PC modem 2) On Basic Tab, Set the command %E0 4) On Dial Options, Set the command &A1 AN-0117-ENG rev4.1 Page 12

Appendix 1 - Using GDTool with the GDW11 1) Connect PC to Modem using a straight through MC9/9 Modem cable then Select Autoconnect and GDTool will search for the correct Serial rate and parity 2) On Basic Tab select no of rings to auto answer (S0) to be 1 and +WRST to be enabled, 35:35 for the Delay and then click the Write Button on that page to save to the modem 3) On Serial Tab set up as shown here to give the AT commands +IPR=9600; +ICF=3,4; +IFC=0,0; and E0V0Q1&D0 for the PLC modem and E1V1Q0&D2 for a PC modem then click the Write Button on that page to save to the modem. Note: These settings can also be used on the GD-01 GSM modem NOTE 1: All other settings are default Using the Terminal command box enter the following commands followed by ENTER: AT+WOPEN=0 AT+CREG=0 AT+CGREG=0 AT+WIND=0 AT+CGEREP=0 AT+CRC=0 AT+CMEE=0 AT+CLIP=0 AT+WRIM=1 AT&W These commands stop all of the unsolicited GSM and GPRS status messages AN-0117-ENG rev4.1 Page 13

Appendix 2 - Increasing Connection Speeds It is possible to increase the RS232 port speed on the Omron PLCs to increase the speed of connection, once the connection has first been tested at 9600 using the settings detailed in Sections 1 to 3 of this document. To increase the port speed, follow the steps shown in Section 1 to setup the PLC s RS232 port, but use up to one of the speeds for the particular PLC range as shown in the table below in place of the 9600 port Custom Communication Settings. Omron PLC Series Port Speed CQM1 19200 C200 19200 CJ 57600 CPM1 19200 CPM2 19200 CS 57600 CV 19200 NOTE: The Modem settings used throughout this document have had 9600 set on both the serial port and the Line Modulation between the Modems, with the exception of the TD-33 which uses its Autobaud setting as Default. It is possible to use the DIP Switch settings for the TD-36, TD-36/485 and TD-35 Modems to force the Modems serial port speed and data format as well as the Line Modulation speed. To force the serial port speed, data format and Line modulation speed the TDW33 will require its settings to be updated using TDTool2 and the GDW11 will require its settings to be updated using GDTool. AN-0117-ENG rev4.1 Page 14

Appendix 3 - Using TOOLBUS Protocol Some applications may require the use of Toolbus instead of Sysmac Way. When using Sysmac Way, it is possible to enter custom settings for all of the PLCs, even though the Default settings are 9600,7,E,2. With Toolbus some PLCs have their data format settings fixed although the data rate can be changed to the same rates as with Sysmac Way. The table below shows the Toolbus settings for the different PLC types with the settings editable unless otherwise specified. Omron PLC Series Port Speed CQM1 19200 C200 19200 CJ 57600 CPM1 19200 CPM2 19200 CS 57600 CV 19200 Default Data Format 7,E,2 7,E,2 Fixed at 8,N,1 7,E,2 7,E,2 Fixed at 8,N,1 Fixed at 8,O,1 If the Toolbus protocol is required and Sysmac Way cannot be used then set up the RS232 port using the correct settings for the PLC type as shown in the table above. Then use CX Programmer to set up the port rate and format using the procedure shown in Section 1 but now with the required data rate and format. If the Modems have been set up differently than described in this document then please check the settings to ensure that the Modems will work with the new data rate and formats used here. AN-0117-ENG rev4.1 Page 15

Appendix 4 - Additional RS232 ports and cables There are additional RS232 adaptors that can be used on some of the Omron PLC s such as the CIF-01 cable, CIF-02 cable and a Serial Communications module. When using the Serial Communications module ensure that the Host Link Unit Number used in the PLC s Communications Parameters matches that set on the Modules rotary switches. Also check that the Module has been configured with the correct port parameters under the Software Switches in the IO Table. The IO Table can be edited offline then downloaded to the PLC, but the Software Switches for the Module must be set when Online in Program Mode. The Additional RS232 ports and cables can be setup as shown in this document using Sysmac way 9600,8,N,1. Then, once successful communications have been established, the data rate can be increased or the Toolbus protocol and data format can be used. NOTE: The CIF-02 cable will need to be disconnected at both ends to reset it before any new settings can be used AN-0117-ENG rev4.1 Page 16

Application Note Appendix 5 - Alternative Westermo to Omron Connections There are many other ways of connecting Omron PLC s using Westermo devices. There are some example applications shown below, but for any other connection method please contact Westermo. The first applications shown below use the RS232 Fibre Optic Line Sharing modems to create Linear and Redundant Ring configurations. The first Ethernet example application shows the SDW541 Ethernet Switches connected by up to 2Km of Multi Mode or up to 15Km of Single Mode Fibre Optic Cable. The second Ethernet example application shows a Redundant Fibre Optic Ethernet ring using Switches that can recover from a breakdown of the ring within 30mS. ODW622 RS232 Linear Fibre Optic Network SCADA or programming PC ODW632 RS232 Fibre Optic Ring SCADA or programming PC Fibre Ring Ethernet and Fibre Optic Networks SDW541 EDW100 EDW100 Redundant Ring Switches EDW100 SCADA or programming PC using SerialIP SCADA or programming PC using SerialIP EDW100 Serial Up to 2Km MM/ 15Km SM of Fibre Ethernet Ethernet SDW541 Serial AN-0117-ENG rev4.1 Page 17

Application Note Appendix 5 - Westermo ED-210 to Ethernet Enabled PLC s It is possible to use Westermo Modems with Westermo ED-210's to either link two Ethernet Networks or to connect to a PLC Ethernet Network using Microsoft Windows Dial Up Networking. Dial Up Networking SCADA or programming PC Note: The Modem Type used for the following Dial up Networking example was a TD-35 LV. The Article number for a Westermo Null Modem Cable, used to connect the Modem to an ED-20, is 9450-0210. LAN PSTN Connecting Ethernet Networks SCADA or programming PC LAN Leased Line SCADA or programming PC Note2: It is also possible to connect same subnet networks with a pair of DDW-100 SHDSL Ethernet Extenders using existing twisted pair cable e.g. DH+ cable, in the same manner as shown above with the DDW-100s being used in place of the ED-210's. AN-0117-ENG rev4.1 Page 18

OMRON Electronics Ltd Opal Drive Fox Milne Milton Keynes MK15 0DG Web: www.omron.co.uk Main Office - 01908 258 258 Fax: +44(0) 1908 258 158 Tech Support - 0870 752 0871, uk_techsupport@eu.omron.com Sales support - 0870 752 0861, oeeuk_sales@eu.omron.com Westermo Teleindustri AB SE-640 40 Stora Sundby, Sweden Westermo Web site: Sweden www.westermo.se support.sverige@westermo.se Phone: +46 (0)21 548 08 00 Fax: +46 (0)21 351850 France www.westermo.fr support@westermo.fr Tél : +33 1 69 10 21 00 Fax : +33 1 69 10 21 01 United Kingdom Web: www.westermo.co.uk technical@westermo.co.uk Telephone: +44 (0)1489 580585 Fax: +44 (0)1489 580586 Singapore sales@westermo.com.sg Phone: +65 6743 9801 Fax: +65 6745 0670 Germany www.westermo.de support@westermo.de Tel: +49(0)7254 95400-0 Fax: +49(0)7254-95400-9 International support@westermo.se Phone: +46 (0)16 42 80 00 Fax: +46 (0)16 42 80 01 AN-0117-ENG rev4.1 Page 19