PR109B and PR110B LAN Reader Module Security Systems

Similar documents
CM705B - Universal Expander Module CM707B - Plug On Zone Expander Security Systems

AC-115 Compact Networked Single Door Controller. Installation and User Manual

Digital Keypad Use s Manual

VARIO PROX CARD READER INSTALLATION MANUAL

Solution 144 The Integrated Access Control & Alarm System made for your business

Secure Keypads for access control

VR8. User Guide Intruder Alarm System

INSTALLATION GUIDE. Card Reader & Controller with KIM Swipe Reader for Solitaire 850 / 950 / 850L Learnlok PK2930

GSM Autodialer Professional GJD700 Speech & Text Autodialer

FIREDEX Conventional Fire Panels

Solution 16 plus. User Guide Security System

PK-01. Standalone door control module. SATEL sp. z o.o. ul. Schuberta Gdańsk POLAND tel

Matrix 424/832/832+ ICON & LCD User Manual. Software Version 5 RINS EN Security Grade 2 Environmental Class 2

MONITOR ISM / AFx Multi-Tenant Security System User Guide V1.3

Using your LED Plus keypad

AUTODIALLER / QUICKDIALLER - SA132

NetworX Series. NX-216E Zone Expander Module Installation and Startup

ACTIVE 5 ENGINEERING MANUAL

SSW-iLM Keypad. Wire Harness Configuration. Note: This product is designed to be installed and serviced by security and lock industry professionals

TX GSM SMS Auto-dial Alarm System. Installation and User Manual

SCORPION. micron security products

500r+ Installation and User Guide

Automatic Telephone Dialer TD-101(W)

INSTALLATION MANUAL XM3 Reader

ATS Control Panel. User s Manual

ICP-CP500. User's Guide ICP-CP500 Codepads

CONTENTS QUICK SETUP & INSTALLATION USER MANUAL. SUPA8 Quick Setup & User Manual

PROXIMITY CARD READERS C-10, C-20, C60, C70

SECURITY ALARM CONTROL PANEL QUICK SETUP & USER MANUAL

Control/Communicator Installation Manual

Alarm Security Kit - NVR

KCIEN KCIENSBP. Heavy Duty Stainless Steel Illuminated Keypads INSTALLATION MANUAL. Range: DIGICODE (Stand-Alone Keypad)

User Manual. Before installation and use, please read the user manual carefully.

GSM Alarm System User Manual

CS848E Receiver for 868GEN2 Devices Installation Sheet

TS510 & TS500. Installation & User Guide. Compatible Equipment

User Guide Premier Elite 24/48/88/168/640

How To Program An Autodialer

How To Control A Car Alarm On A Car With A Remote Control System

Understanding the Code Pad lights...4. Code Pad tones...5. Fully arming the system On MODE...6. Fully arming the system - Quick Arm MODE...

NetworX Series. NX- 4/8 Code Pad. User Manual (Australian Version)

Solution 6000 Security Systems

GE Concord 4 Quick User Guide

SPR-5 FOUR SECTOR COMPOS I TE CONTROL UN I T.

9452/9453 Installation and User Guide

D24 ALARM CONTROL PANEL USER S MANUAL REVISION 1.1 A$12.00 INC GST

Quick Installation Guide LCD GSM ALARM SYSTEM LH

Security System User Guide

CSP Combined Series. Telephone Door Entry. with. Proximity Keyfob Access

Solution-16 Operators Manual ISSUE 1.60

Multi Function, User Configurable Remote Vehicle Security System with 4 Button Replaceable Membrane Remote Transmitter

How To Power A Power Control On An Ip40 (Ipl) With A Power Supply (Iplug) With An Ip20 Controller (Iphones) With Power Control (Power Control) With No Antenna) With The Ip20 (Power)

CA60 Plus Software Version 3.1 User Manual May 2000

HONEYWELL COMMERCIAL FIRE/BURG PANEL UL LISTING REQUIREMENTS (Compiled from VistaFBPT Installation Instructions V1 Rev A 11/12)

Business/Home GSM Alarm System. Installation and User Manual

GSM AD05 Slave GSM Auto Dialer- Instruction Manual

IDS X-Series User Manual D Issued July 2012

2.0 Installation 1. Remove the cover using a small flat blade screwdriver. Figure 2: Cover Removal

Model 201 Wiegand Touchpad Reader Installation Guide

PK5500 v1.1 Installation Instructions

SECURITY SYSTEM NOTES. EMERGENCY ACTIVATION KEYS (check if enabled) PROGRAMMED FUNCTIONS

NX-591NE-GSM NetworX GSM 3G HSPA+ Module Installation Sheet

HyperAccess Access Control System

TABLE OF CONTENTS FEATURES 2 SPECIFICATIONS 2

User Manual GSM Alarm System. All rights reserved by Delta Security Co., Ltd

USER GUIDE SERIES 4250 AUDIO ALARM CONFIRMATION SYSTEM CONTROL UNIT

MOBILE CALL GSM Alarm System User s Manual

PAC1 Door Access Controller

The Challenger Version 8 User Guide

NESS D Zone Control Panel and Dialler OWNER S MANUAL

D1260/D1260B. Keypad. National Security Systems Inc (800) Owner's Manual

tattletale User Guide Consumer unit version P a g e

PCS300 Universal IP Reporting Module V1.0

HILLS Series LED Code Pad User Manual

New GSM Alarm System. User s Manual. Profile For a better understanding of this product, please read this user manual thoroughly before using it.

SECURITY SYSTEM NOTES

TABLE OF CONTENTS FEATURES

Operating Guide. Alert 8D Version 8 Zone Controller Arrowhead Alarm Products Ltd

INSTALLATION MANUAL PC2525. Version 1.1

Auto Dialer. Manual E-921APQ E-921GPQ

User Guide. RX-406 LED Keypad For CAPTAIN-I Ver.5.5 & up

Wireless Home Security Alarm System AM 500

DIVISION 28 ELECTRONIC SAFETY AND SECURITY SECTION SECURITY AND ACCESS CONTROL SYSTEM

INTELLIGENT CONTROL MODULE SA-2000-II HARDWARE MANUAL. Access Technologies International, Inc.

INSTALLATION/PROGRAMMING INSTRUCTIONS 928 ENTRYCHECK

User Manual Wireless Alarm System RINS PIEZO WARNING The wireless system contains a loud siren, please be aware of this after an activation

1R / 4-BUTTON SERIES

Accenta/Optima. Engineer s Manual. Honeywell Security. 8SP399A - Accenta mini panel with remote LCD keypad and communicator outputs.

Users Guide to Keypad Functions

WIRELESS ALARM KIT INSTRUCTION MANUAL COMPLETE ALARM SYSTEM FOR HOME OR BUSINESS. Model Number: IT214054

NOTE: It is the responsibility of the installation organization to have only technically qualified personnel performing the installation.

Security System. User's Guide. Keypad

2 4PI175 issue 1_6/01. How to unset system in alarm. Programs 1, 2 and 3. Access codes. How to operate Personal Attack

for DNE-K07 Reference and Installation Manual

ICP-CC488. Installation Guide ICP-CC488 Control Panel

IDS. Users Guide to Keypad Functions S E C U R I T Y MANUAL NO B ISSUED AUG 2002 VERSION 1.18

Intelligent GSM Auto-dial Alarm System User s Manual

AD-01 Slave Auto Dialer. Owner s Manual

PC Tab INSTALLATION MANUAL SECURE-IT, INC. EAST LONGMEADOW, MA / (fax)

WIRELESS HOME ALARM SYSTEM (WHA1)

Transcription:

PR109B and PR110B LAN Reader Module Security Systems EN Security System

PR109B-PR110B LAN Readers PR109B - Black and PR110B - White The PR109B and PR110B LAN readers feature our proprietary 40 bit transmission format and can be used to provide alarm and or access control functionality when used on selected Solution security control panels. Reader Compatibility Panels Supported Version Keypads Supported Solution 16i 2.19 Up to 8 Solution 16X 2.00 Up to 8 Solution 144 GRAPHIC 2.00 Up to 16 Solution GRAPHIC 2.00 Up to 16 Table 1: LAN Reader Compatibility The PR109B and PR110B readers include red, green and blue indicators which are used to show area and or door lock status at all times. The reader connects to the control panel via the RS485 encrypted LAN and occupies a standard keypad position in the panel configuration. Various options can be configured via the Devices - Keypad & Readers menu in panel programming. User access events are stored in the panel log and can also be reported if required. Reader Addressing Figure 1: PR110B Reader Each reader fitted to the system must be assigned a unique address on the LAN. The PR109B and PR110B readers include a rotary address switch for quick selection. The following table shows the address setting for each reader as well as the number of keypad, reader devices each panel can support. Reader Address Setting Address No Keypad No 1 1 2 2 3 3 4 4 5 5 6 6 7 7 8 8 9 9 10 10 11 11 12 12 13 13 14 14 15 15 16 16 Solution 16i Panel Solution 16X Panel Solution 144 Panel Solution GRAPHIC Panel Table 2: Address Table Figure 2: Address Switch Only 1 reader can be assigned to each address. All readers are supplied from the factory set to address 1. You must power cycle the panel or perform a LAN scan whenever you change the reader address. Box Contents The PR109B and PR110B contains the following parts. Reader Base Unit Reader Cover Mounting Template Instruction Sheet 2 x (M3 x 6mm) Hex Screw 1 x 2mm Hex Key 2 Bosch Security Systems 09/11 PR109B-PR110BIRG FTR1.1

Installation The reader should be installed onto a solid surface using suitable mounting fixtures. Wiring should only be performed while the control panel is powered off. Step 1) Using the 1:1 mounting template supplied, mark out the location of the 2 mounting holes and the cable exit hole before drilling out all points as necessary. 92.0mm PR109B & PR110B Mounting Template Scale 1:1 6 x 4.0mm (1/8 ) holes Tamper Switch Do Not Create A Hole In This Location 84.0mm Reader Operation PR109B-PR110B LAN Readers can be configured to provide system area control, door access control or both depending on the installation requirements. As there is no LCD display on the readers, feedback is provided via the red, green and blue indicators and the reader sounder. The readers also include an egress input and lock output which can be used to control door access if required. Using the on board lock output is not recommended when the reader is being used on an external wall of the building. In this case it is recommended that you run the lock control wires directly to an output located on the main panel or output expander module located inside the building. LED Indicators The Red and indicators on the reader show area status while the Blue indicator shows door status. The addition of the Blue indicator allows the system to display both area and door status at the same time if required. Connection Cable Entry Point 48.0mm PR109B & PR110B Mounting Template.ai Rev 1 Figure 3: Mounting Template (Not to Scale) Step 2) If the reader is to occupy an address on the LAN other than address 1, you will need set the required address before mounting. Note each reader on the system must have a unique address. See Table 2: for more information. Step 3) Once the address has been set, terminate the required wires referring to the Connection Diagram on page 6. Unused wires should be insulated to prevent short circuits. Step 4) If using the on board lock output to open the door, you must make sure to use a relay and protection diode as shown. Step 5) Once the wiring is complete, mount the reader to the wall and fit the cover plate using the M3 x 6mm hex screws. Bosch Security Systems 09/11 PR109B-PR110BIRG FTR1.1 LED Operation For Area Control Led Condition Meaning Red On On Both On Red On and Alternate Both Off Area All On Area Alarm Area is OFF Area not ready to turn on - zone(s) unsealed Area armed in Part mode and all zones sealed. Area armed in Part mode with zones unsealed. Keypad initialising during power up or LAN scan. Home Area and Access Group not programmed or keypad not powered. Table 3: Reader LED s - Area Control The LED indicators will only display the status of the programmed home area. You cannot move between areas from this reader. If you require multiple area status visibility you should use a display keypad like the CP700B. 3

PR109B-PR110B To have the reader control an area on the alarm system you must assign the reader to a home area. See the Devices-Keypads & Readers-Home Area menu option in panel programming. If alarm system control is not required then you should set the home area option to No Area. When the reader has been configured to do alarm area control only, the blue indicator will remain off at all times. To have the reader control an output (door) on the system you must assign the reader to an access group. See the Devices-Keypads & Readers-Access Group menu option in panel programming. Once assigned, the on-board Lock output and Egress input are automatically assigned to the same access group as the reader. LED Operation For Door Control Led Condition Meaning Blue On Door Locked Blue Fast Flash Door Unlocked Blue Blue Blue Continuous Fast Flash 2 Flashes Alternate Off Door manually unlocked or overridden. Door automatically unlocked by schedule or time zone. Reader initialising during power up or LAN scan. Access Group not programmed or reader not powered. Table 4: Reader LED s - Access Group Door Control If both alarm area and door control is required, you must assign a home area and an access group to the reader. When the reader has been configured to do door control only, the green and red indicators will remain off at all times. Setting the reader volume to off will stop all audible warning signals at the reader. Event Fire Alarm Burglary Alarm Trouble Exit Delay Entry Delay Error Chime Alert Reader Alert Tones Alert Tone Emitted If the system registers a fire alarm, the reader will sound 3 short beeps followed by a 1.5 second pause. This will repeat until reset by the user or until the siren run time expires. If the system registers a burglary alarm, the reader will sound a continuous siren tone until reset by a user or until the siren run time expires. If a system trouble condition occurs, the reader will sound 4 x fast short beeps followed by a 5 second pause and will repeat this tone until the user acknowledges the trouble condition from a display keypad The exit delay warning will sound 1 short beep every second when the area the reader has been assigned to is armed. During the last 10 seconds of exit time the warning tone will speed up indicating that the time has nearly expired. The hi/lo entry delay warning tone will sound once every second when an entry delay zone in the area the reader has been assigned to is triggered. If the system is not disarmed before the entry time expires then an alarm will occur. If an invalid token is presented to the reader the keypad will sound a 2 second warning tone indicating that the token was rejected for some reason. See the panel log for more details. If chime mode is active then the reader will sound fast short beeps to alert the user when a zone programmed for chime is opened. Chime mode is only applicable when the area is disarmed. Table 5: Reader Tones Alert Tones The reader emits several distinct tones to alert you to particular system events. The volume level cannot be adjusted on the external LAN readers however it can be turned off via panel programming by setting the reader volume to the lowest level. See the Devices-Keypads & Readers-Commands menu in panel programming. When readers are installed outside the premises, you may prefer that the alert tones are disabled. See the Devices-Keypads & Readers-Indicator Options menu in panel programming to disable these features. 4 Bosch Security Systems 09/11 PR109B-PR110BIRG FTR1.1

PR109B-PR110B Egress and Lock Control The LAN reader includes an egress input and a lock output which can be used to simplify the wiring when the LAN reader is being used for door or access control. The lock output consists of a protected open collector transistor that can be used to operate a relay to control the door lock. The output will go from open to low for fixed 5 seconds whenever the associated access group or door assignment is triggered. The on board lock output will operate for a fixed time period of 5 seconds when triggered. If a different time is required then you should use another output on the system to operate the door lock. The lock output, and LAN+ power supply are not designed to operate and power the door lock directly. You should always fit a relay and protection diode to the lock output in combination with a separate power supply. The optional CM444B Relay Module has been designed to suit this task. If you require the door to operate when the mains power has failed then you will also need to fit a battery backup to the external power supply. See the wiring diagram in Figure 4: for more details. The Egress input on the LAN reader allows you to simplify the wiring required to implement an egress button on the inside of the door. The egress input triggers the lock output on the LAN reader by operating or firing the associated Access Group or Door Assignment. The egress input should be connected via a momentary or push button switch to reader ground. When the button is pressed the lock output on the reader will trigger for a fixed 5 second period. Configuration Examples Alarm control function only. 1) Install the reader as per instructions. 2) Set the home area for the reader (keypad). 3) Set reader (keypad) options as required. 4) Assign users to the area. Access control function only. 1) Install the reader (keypad) as per instructions. 2) Set the access group for the reader (keypad). 3) Set reader (keypad) options as required. If using the on board lock output, jump to step 6 or. 4) Set output to access group to operate door. 5) Set output event assignment. 6) Assign users to the access group. Both Alarm and Access control functions. 1) Install the reader (keypad) as per instructions. 2) Set the home area for the reader (keypad). 3) Set the access group for the reader (keypad). 4) Set reader (keypad) options as required If using the on board lock output, jump to step 7 or. 5) Set output event type to access group. 6) Set the output event assignment. 7) Assign users to the area. 8) Assign users to the access group. The above examples show how to configure the PR109B and PR110B readers to control an area and or a door on a Solution 16i panel. Consult the installation manual for programming information if you are using a different panel. For greater security, if the egress input is not being used it should be disabled via panel programming. See Devices-Keypads & Readers-General Options in panel programming. Any zone on the system can be configured to trigger an access group and can therefore also be used to operate the lock output on the LAN reader. Tamper Switch Operation The LAN reader includes an built-in tamper switch which will trigger when the cover is removed or the unit is removed from the wall. You should adjust the angle of the switch leaver to suit the wall surface. If the tamper alarm is not required it can be disabled via panel programming. Bosch Security Systems 09/11 PR109B-PR110BIRG FTR1.1 5

PR109B-PR110B Connection Diagram The optional CM444B relay module provides an easy way to interface the readers lock output to the door lock. Because of its small physical size (12.5 x 46 x 12mm) it can be easily located in the wall cavity if required. The mechanical tamper switch provides tamper monitoring to the front housing and to the rear wall mounting. The leaver on the switch should be carefully bent using pliers so that the switch is closed when the reader is installed on the wall. Thanks tamper switch can be disabled via panel programming if required + CM720B or CM723B Power Supply (Battery backed up) + - DOOR LOCK + TO DOOR LOCK N/O COM N/C CM444B RELAY CARD CM444 Relay Card DF70 +12V + - PROTECTION DIODE Wiring Legend RED = LAN + BLACK = LAN - WHITE = LAN A BLUE = LAN B YELLOW = LOCK GREEN = EGRESS CONTROL PANEL MODULE LAN - A B + EGRESS INPUT BL WH BK RD RD N/O YL Lock Output GN Egress Input To Control Panel The egress input is low (0V) to trigger. Disable via panel programming if not being used. Address Select Switch. Keypads and Lan Readers must be set to a unique address as per Table 2: Address Table on page 2 All LAN Readers are supplied from the factory set to Address 1. Figure 4: PR109B and PR110B Connection Diagram You must power cycle the panel or perform a LAN scan after connecting the PR109B or PR110B for the system to initialise the reader. 6 Bosch Security Systems 09/11 PR109B-PR110BIRG FTR1.1

Compatible Cards and Tokens PR109B-PR110B The following user credentials are compatible with the PR109B and PR110B readers. P/N - PR250B ISO Prox Card P/N - PR260B Clam Shell Prox Card P/N - PR201B Prox Token with Keyring DF-77SGW DF-77SGW P/N - PR200B Prox Token PR109B - PR110B Specifications Part Number: Format: Operating Voltage: Module Connection: (RS485 LAN) Lock Output: Egress Input: PR109B - Black - LAN Reader (RS485). PR110B - White - LAN Reader (RS485). 40bit Proprietary, 125Khz 10.0V D.C - 14.5V D.C. @ 100mA Max. Max total LAN length using multi strand security cable = 500m, Max total LAN length using 2 pair twisted shielded data cable (Belden 8723) = 1200m. See full control panel manual for complete wiring instructions. Protected open collector transistor output 500mA. Low to trigger. Can be disabled via software control. Dimensions: 74mm(W), 23mm(D), 116mm(H). CM444B = 46mm(W), 12.5mm(D), 12mm H) Environment: Fixing Method: Warranty: -30 to 55 C RH 5 to 85% at 30 C non-condensing. The PR109B and PR110B should be mounted on a sturdy vertical wall using fixtures appropriate for the wall construction type. 3 years from date of manufacture (return to base). N12138 N12138 RoHS In the interest of ongoing product development this document is subject to change without notice. Bosch Security Systems 09/11 PR109B-PR110BIRG FTR1.1 7

Bosch Security Systems 25 Huntingwood Drive Huntingwood, NSW 2148 Australia Phone: +612 9672 1777 Facsimile: +612 9672 1717 2011 Bosch Security Systems PR109B-PR110BIRG Issue FTR1.1