Disabled Persons Toilet Alarm (DPTA)

Similar documents
Disabled Toilet Alarm. Contractor Pack. Installation & Operating Instructions

BARDIC. 4 & 8 Zone Fire Panels Zircon range. Data, installation, operation and maintenance. by Honeywell

FIREDEX Conventional Fire Panels

GST301. (Single Protection Zone) Operation Manual

WD-AMX Water Detection Controllers

ACTIVE 5 ENGINEERING MANUAL

AC-115 Compact Networked Single Door Controller. Installation and User Manual

Residential Gateway (RG) Battery Backup

AlarmSense 2-wire detection and alarm system. Product Guide

9448 Installation and User Guide

Back-UPS 650 VA 120 V with AVR (BX650CI-LM)

INTRODUCTION. The data provided is for The Standard Products and any variation will be dealt with at the end of this manual.

conventional system operation

ICP-CP500. User's Guide ICP-CP500 Codepads

EKOS Cart. Instructions for Use

LD2 One & Two Zone Water Detection Alarm Installation and Operation Manual

ER-1 Emergency Response System INSTALLATION & PROGRAMMING GUIDE

Conventional Fire Detection and Extinguishant Control System Specification

TMS TANK MANAGEMENT SYSTEM

ALARM ANNUNCIATOR ME INSTRUCTION MANUAL

DORMA MODEL PS-406BB POWER SUPPLY INSTALLATION INSTRUCTIONS

CB200W Water Leak Detection Panel Application Guide

(68.52) X. June 2000 Supercedes February xenex CONVENTIONAL FIRE DETECTION & ALARM SYSTEM. we business differently

BREEAM CRITERIA WATER LEAK DETECTION SYSTEM Type WG2 - CONTROL PANEL CONNECTIONS

INSTALLATION MANUAL PC2525. Version 1.1

CSP Combined Series. Telephone Door Entry. with. Proximity Keyfob Access

Back-UPS Pro 1300/1500 Installation and Operation

CONTENTS 4. HOW TO UNSET THE PANEL...7

TABLE OF CONTENTS FEATURES

TS510 & TS500. Installation & User Guide. Compatible Equipment

TABLE OF CONTENTS FEATURES 2 SPECIFICATIONS 2

Fire Alarm Control Panel. Family. Operating Manual

INSTALLATION GUIDE. Card Reader & Controller with KIM Swipe Reader for Solitaire 850 / 950 / 850L Learnlok PK2930

AUTODIALLER / QUICKDIALLER - SA132

User Manual. ATX12V / EPS12V Power Supply TG-I460R (460W+460W) TG-I550R (550W+550W) Switching Power Supply User Manual

500r+ Installation and User Guide

FIRE ALARM PANEL & SYSTEM OPERATION ID50 SYSTEM. The Fire Alarm System can be activated in the following ways :~

CM705B - Universal Expander Module CM707B - Plug On Zone Expander Security Systems

USER S MANUAL. MaxPower UPS. Uninterruptible Power System 28-2MAXPO0018

EDA-Z5008 & Z5020. Radio Fire Alarm System. User Manual

9452/9453 Installation and User Guide

FIRST ALERT INSTRUCTION MANUAL FOR FA 270 KEYPADS SECURITY SYSTEM

Manual for Fire Suppression & Methane Detection System

Communication A BRITISH MANUFACTURER. Features:

MEDICO Medical Alert Autodialer. Proudly Manufactured by Arrowhead Alarm Products. User Guide. Proudly Designed and Manufactured in New Zealand

User s Manual AURORA 1.2K/2.2K

HM-W536 Install Guide

Premier M Plus & Infinity 8

AIS750 Series Alarm Annunciator

POINTS POSITION INDICATOR PPI4

AUTOMATIC TRANSFER SWITCH CONTROL UNIT OPERATOR S MANUAL

Installation and Operation Manual Back-UPS BX800CI-AS/BX1100CI-AS

HAM841K ALARM CONTROL PANEL FOR COMMERCIAL AND RESIDENTIAL SECURITY SYSTEMS

Using your LED Plus keypad

CONTENTS. GST102A/104A/108A/116A Conventional Fire Alarm Control Panel Installation and Operation Manual

FA-300 Series. LCD Fire Alarm Control Panel. User Guide. LT-954 Rev. 0.1 February FA-300 SERIES Fire Alarm Control Panel

AMI MARINE (UK) LTD BRIDGE NAVIGATIONAL WATCH ALARM SYSTEM (BNWAS) Operation Manual KW810

SFC-200 SERIES LCD FIRE ALARM PANEL

AARC-EVAC Portable Hand Held or Fixed Transmitter with SOS assist - ATX43E25 SAFETY ALERT SYSTEMS

PC Tab Security System INSTRUCTION MANUAL

MODEL 5010 DUAL CHANNEL SMOKE/FIRE DETECTION MODULE

A.1. a Division of Pittway Corporation. Documento: M MGAS-ENG. Edizione: 01/1997 Rev.:

CR Band Auto Set Dual Alarm Clock Radio ROBERTS. Sound for Generations. Please read this manual before use

Digital Keypad Use s Manual

Fire Pump Controllers Remote Alarm Panels

Power Generation. Power Control PCL System Generator Set Control

How To Use A Power Supply Unit (Upu)

ALARMS-xx. Remote Alarm Unit Setup Guide RESET ALL

DTW Works Master Specification Version 2006

350, 500, 650 and 1000 MODELS

SECURITY SYSTEM NOTES AREA LISTINGS SPECIAL CODES ENTRY / EXIT DELAY TIMES ARM / DISARM CODES ZONE DESCRIPTIONS

FIRE ALARM SYSTEM TECHNICAL SPECIFICATIONS Page 1 of 10

CO2 Alarm. Operation. Application

DIGITAL ALARM II FOR HOSPITALS AND LABORATORIES INSTALLATION AND OPERATING INSTRUCTIONS

SFC-200 SERIES FIRE ALARM CONTROL PANELS. SFC-200 Series Fire Alarm Control Panels. Features. Description

*.ppt 11/2/ :48 PM 1

INSTALLATION MANUAL CONTENTS

Kit Watt Audio Amplifier

IDS X-Series User Manual D Issued July 2012

INTRODUCTION 2 Features... 2 Specifications... 2

MONITOR ISM / AFx Multi-Tenant Security System User Guide V1.3

Installation and Operation Back-UPS 1250, 1300, 1500

User s Information Guide R1A

Control/Communicator Installation Manual

Thyristor-controlled power supplies and battery chargers

Instruction Manual. 2in1 LAN Tester & Multimeter. Model: LA-1011

LTR Series Uninterruptible Power Systems 700 VA KVA. General Specification

Online UPS. PowerWalker VFI 1000R/1U

Repeaters and Mimics Data Sheet

CAPTAIN 6. USER GUIDE System ver Zones Intruder Alarm System. PIMA Electronic Systems Ltd.

CruzPro VAF110. AC Volts, Amps, Frequency, kw Monitor

INSTRUCTION MANUAL PC255O

SECURIT 800L+ CONTROL PANEL

SPECIAL CODES AUXILIARY CODES SYSTEM NOTES

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

Section D..General Auto Electrical Corporation

SECTION DETECTION AND ALARM

GSM AUTO DIALER. Remote Monitoring & Control using your mobile phone.

10000HXL31/15000HXL31/20000HXL31

Introduction. Refrigerant Leak Detecting System. Feature and Benefits

Transcription:

User Manual / Disabled Persons Toilet Alarm (DPTA) DPTA-KIT1 DPTA-KIT2 DPTA-KIT3 DPTA-KIT4 Issue #1 Issue Date 26/09/2008 Revision #5

Contents / Contents Section 1 Introduction 3 Section 2 Features 4 Section 3 Typical Installation 5 Section 4 Product Specifications 6 Section 5 Electrical Requirements 10 Section 6 Wiring Diagram 11 2 Issue #1 Issue Date 26/09/2008 Revision #5

Section 1 Introduction / 1 Introduction This Disabled Persons Toilet Alarm Kit is available in 1, 2, 3 or 4 zones (where one zone is used for each toilet). It has been designed for use in disabled persons dwellings typically for disabled toilets where this design process considered the requirements of BS8300. The system consists of a 4 zone control panel (DPTA-CP4) which is (for each zone) connected to a Pull Cord (DPTA-PC), Remote Reset (DPTA-RR) and Remote Indicator (DPTA-RI). These connected items are known as field devices which provide the Control Panel with the necessary input and output signals to allow the system to function. These field devices are categorised as follows; Pull Cords (DPTA-PC) are Call Devices which are ceiling mounted pull cords used to generate an alarm activation by a person in distress or requiring attention from a carer. When a call devices is activated the system will generate an alarm and the Remote Indicator (DPTA-RI) will illuminate & sound. Remote Resets (DPTA-RR) are Reset Devices which are generally wall mounted and consist of a push button which is pressed to cancel an alarm activation. Remote Indicators (DPTA-RI) are Warning Devices that are generally wall mounted devices which during an alarm activation will alert cares / staff of a person requiring attention. Warning devices typically have visual and audible element within the same housing, but devices with only audible or visual elements may be fitted to a system. The control panel (DPTA-CP) is powered by mains supply and an optional battery back-up can be installed which allows the system to function during a power outage. Issue #1 Issue Date 26/09/2008 Revision #5 3

Section 2 Features / 2 Features Simple 3 wire operation for all field devices Control Panel supporting up to 4 zones Simple maintenance and fault diagnosis. On board buzzer in both Control Panel & Remote Indicator Zone LED indication on Control Panel Full range of field devices available (i.e. Pull Cord, Remote Reset & Remote Indicator) System silence/mute option from Control Panel Local (at Control Panel) or remote (at Remote Reset) reset options Optional battery back-up Auto shut down function to save battery power 4 Issue #1 Issue Date 26/09/2008 Revision #5

Section 3 Typical Installation / 3 Typical Installation The following illustration shows how the Control Panel and field devices are connected in a typical installation for a single toilet; Pull Cord (DPTA-PC) Remote Resets (DPTA-RR) Up to four toilets on one panel Control Panel (DPTA-CP) Remote Indicators (DPTA-RI) Issue #1 Issue Date 26/09/2008 Revision #5 5

Section 4 Product Specifications / 4 Product Specifications 4.1 DPTA-CP Control Panel (Surface/Flush Mounted) a. Power Supply Mains Input Voltage Quiescent Standby Current Maximum Overall Supply Current DC Input Voltage 230VAC 50Hz/60Hz 3mA DC (Buzzer Muted) 250 ma DC (Maximum) 12VDC Battery b Button Functions Button System Status Operation Function Silence Alarm Activation Press for 0.5 Seconds Mute Control Panel Reset Alarm Activation Press for 0.5 Seconds Rest All Zones Zone 1 Alarm Activation Press for 0.5 Seconds Reset Zone 1 Zone 2 Alarm Activation Press for 0.5 Seconds Reset Zone 2 Zone 3 Alarm Activation Press for 0.5 Seconds Reset Zone 3 Zone 4 Alarm Activation Press for 0.5 Seconds Reset Zone 4 c. Led s LED System Status LED Response Mains - Green Mains On Constant: Mains Present Battery Back-Up Pulse Every 5 Seconds Battery Saver Pulse Every 20 Seconds Alarm (Zone 1, 2, 3, 4) - Red Alarm Activation Slow Flashing 1.Hz d. Internal Buzzer Type Current Frequency Sound Piezo (PCB Mounted) 5mA maximum 1 Khz Tone 1 Hz Pulse (Alarm Activation) Mute (System Normal) Beep Every 20 Seconds (Battery Saver Mode) 6 Issue #1 Issue Date 26/09/2008 Revision #5

Section 4 Product Specifications / e. Field Device Inputs Number of Zone Circuits 1 Detection Supply Voltage 12 VDC +/- 10% Maximum Current 30mA Detection Mode Monitoring Short Circuit > 30mA Open Circuit < 1.5mA f. Field Device Outputs Number of Zone Circuits 1 Sounder Supply Voltage 12 VDC +/- 10% Maximum Current 200mA Protection Shut Down At Alarm Call 1 Hz Pulse g. Battery Input Charging Voltage Deep Discharge Protection 13.8 VDC Less than 10.5 VDC h. Fuses F1: Auxiliary 500mA Anti Surge 20mm Glass F2: Battery 500mA Anti Surge 20mm Glass i. Housing Front Cover Back Box Maximum Current During Alarm Polycarbonate Fire Retardant Polycarbonate Fire Retardant 30 ma DC (Maximum) 4.2 DPTA-PC Pull Cord (Ceiling Mounted) a. Power Supply Input Voltage Quiescent Standby Current Maximum Current During Alarm 12 VDC 0mA 15 ma DC (Maximum) Issue #1 Issue Date 26/09/2008 Revision #5 7

Section 4 Product Specifications / b. User Operation Action Pull Card Response Alarm Activation c. LED LED System Status LED Response Front Mounted Alarm Activation Illuminates in Sympathy with System d. Termination Device is wired with 3 wires (positive, negative & signal) in and 3 wires (positive, negative & signal) out. e. Housing Material Colour ABS White 4.3 DPTA-RR Remote Reset (Surface/Flush Mounted) a. Power Supply Input Voltage Quiescent Standby Current Maximum Current During Alarm 12 VDC 0mA 15 ma DC (Maximum) b. User Operation Action Pull Card Response Alarm Activation c. LED LED System Status LED Response Front Mounted Alarm Activation Illuminates in Sympathy with System d. Termination Device is wired with 3 wires (positive, negative & signal) in and 3 wires (positive, negative & signal) out. 8 Issue #1 Issue Date 26/09/2008 Revision #5

Section 4 Product Specifications / e. Housings Material Colour ABS White 4.4 DPTA-RI Remote Indicator (Surface/Flush Mounted) a. Power Supply Input Voltage Quiescent Standby Current Maximum Current During Alarm 12 VDC 0mA 30 ma DC (Maximum) c. LED LED System Status LED Response Front Mounted Alarm Activation Illuminates in Sympathy with System d. Termination Device is wired with 3 wires (positive, negative & signal) in and 3 wires (positive, negative & signal) out. e. Housings Material Colour ABS White Issue #1 Issue Date 26/09/2008 Revision #5 9

Section 5 Electrical Requirements / 5 Electrical Requirements A. Power Supply 230V AC at 50/60Hz 12V DC Storage battery Standby Current : 4mA Alarm Current : 250mA (max) B. DPTA-CP Internal Safety Fuses F1 - Auxiliary 500mA, Anti Surge / Timed. The Auxiliary Fuse protects the DPTA-CP circuitry, field devices and field device wiring from current overload. The field device wiring is protected with electronic current limiting. F2 Battery 500mA, Anti Surge / Timed. The battery fuse protects the DPTA-CP battery supply from overload either while charging or in standby. 10 Issue #1 Issue Date 26/09/2008 Revision #5

Section 6 Wiring Diagram / 6 Wiring Diagram DPTA-RR Wiring of field devices for each zone which can be wired in any order once spurred from control panel (DPTA-CP) DPTA-RI DPTA-PC DPTA-CP L N BAT+ BAT- AC 230V 50/650Hz 12V DC Issue #1 Issue Date 26/09/2008 Revision #5 11