User s Manual IOB 49

Similar documents
Product Information. Gateway For Connecting EnDat Encoders to PROFIBUS-DP

Fiber Optic Selector Guide for Analog & Digital Data Links, Contact Closures & Multiplexers

Easy Machining Center Setup

SYMETRIX SOLUTIONS: TECH TIP May 2014

CNC 8055 / CNC 8055i SELF-TEACHING MANUAL ( TC OPTION) (REF 0607) (Ref 0607)

Model 5511 Filler Controller User s Manual Version 1.1 October 2011

Modular I/O System Analog and Digital Interface Modules

Product Information. QUADRA-CHEK 3000 Evaluation Electronics For Metrological Applications

NC-12 Modbus Application

X8 Option 2 - Technology

Course outline. Know Your Machine From A Programmer s Viewpoint 11 If you ve had experience with conventional (non-cnc) machine tools 11

MINIMAT-EC-Servo Screwdriver Spindles

FlexPak 3000 Digital DC Drive Software Reference Manual Version 4.3

An overview of Computerised Numeric Control (C.N.C.) and Programmable Logic Control (P.L.C.) in machine automation

5. Tutorial. Starting FlashCut CNC

INSTALLATION MANUAL XM3 Reader

User's Guide. Integrating Sound Level Datalogger. Model Introduction

Digital I/O: OUTPUT: Basic, Count, Count+, Smart+

Digital and Analog I/O

Analog Servo Drive 25A8

PART 11: START-UP PROCEDURES FOR THE INSTALLER

NX Series Inverters. HVAC Pocket Programming Guide

ACS 800. Supplement Traverse Control Application Program 7.x

Specifying a Variable Frequency Drive s

Installation guide H A. HSI hardwired system interface

PNOZmulti error messages. Configurable Control System PNOZmulti. Error list EN 01

AquaTrend Interface. Model AquaTrend Model AquaTrend/SOM Model51400 PortableAquaTrend. Instrument Manual. Catalog Number

ACS800. Master/Follower Application Guide Supplement to Firmware Manual for ACS800 Standard Application Program

PNOZmulti Configurator V8.1.1

SYSTEM 4C. C R H Electronics Design

Factory Automation SIMATIC LOGO!..0BA6. Colin Limbert. Factory Automation Department. Product Manager LOGO! and S7-200

BROOKFIELD MODEL VTE250 ELECTRIC VISCOSEL PROCESS VISCOMETER. Installation, Operation, and Maintenance Instructions. Manual No.

Software Manual RS232 Laser Merge Module. Document # SU Rev A

SYSTEM 45. C R H Electronics Design

2011, The McGraw-Hill Companies, Inc. Chapter 5

Allen-Bradley/Rockwell

STIM202 Evaluation Kit

Product Information. HMC 6 Hybrid Motor Cable

Supplemental User Guide

omega.com ΩOMEGA RS232 Multi-Drop FMA1600-MDB Multi-Drop Box

INSTRUCTION MANUAL OVERVIEW Remote Meter: MT-5 Remote meter (Model MT-5) is available to connect with solar controller Tracer MPPT series.

Electric Actuator Smart Controller

TwinCAT NC Configuration

Features, Benefits, and Operation

ServoOne. Specification. Option 2 - Technology. x 11. x 8 X 8. x 10. x 9. x 7. x 6 TTL Encoder / TTL Encoder simulation

The Autolab control command is located in the Measurement General group of commands.

Proficiency Test For Machining Center

APPENDIX. SureSERVO QUICK START GUIDE. In This Appendix... Quick Start for SureServo Drives...A 2. Tuning Quick Start for SureServo Drives...

USING WIRELESS DIAGNOSTICS Application Note 31

D-MAX WEB GUIDE CONTROLLER WITH OPERATOR INTERFACE PANEL QUICK START SETUP MANUAL

Device Type Manager (DTM) for AS800

EnDat 2.2 Bidirectional Interface for Position Encoders

Unidirectional Transmitter/ Receiver Units Introduction

Technical data. General specifications. Indicators/operating means. Electrical specifications Operating voltage U B Power consumption P 0 Interface

mecotron Safety relay ESTOP-2 For emergency stop monitoring

Technical Specifications: The specifications represent a particular hardware platform. Application-specific software is provided.

ROC Protocol Specifications Manual

CONTROL SWITCHER User s Manual (Preliminary)

Firmware version: 1.10 Issue: 7 AUTODIALER GD30.2. Instruction Manual

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

ZONE SELECTIVE INTERLOCKING (ZSI) APPLICATION AND TESTING GUIDE SIEMENS WL UL489 AND UL1066 AIR CIRCUIT BREAKERS

PRODUCTIVITY THROUGH INNOVATION 600 CONTROL DIRECT DRIVE TECHNICAL/OPERATION MANUAL

Troubleshooting and Diagnostics

PUSH BUTTON START INSTALLATION MANUAL

USER GUIDE Version 2.0

INTELLIGENT CONTROL MODULE SA-2000-II HARDWARE MANUAL. Access Technologies International, Inc.

/ Instruction Manual. Analog Input/Output Interface Card "OPC-G1-AIO"

The HEIDENHAIN Service You may count on us!

Operation and Installation Manual

PRT3 Printer Module: ASCII Protocol Programming Instructions

TCP/IP MODULE CA-ETHR-A INSTALLATION MANUAL

FAGOR CNC 8055 ia-mc Control

Section 15: Diagnostics

M68EVB908QL4 Development Board for Motorola MC68HC908QL4

Conversion Between Analog and Digital Signals

Mach3 Tutorial Setting up a basic three axis milling machine. Based on Mach3 2.0

Automation Unit TM 1703 ACP Flexible automation and telecontrol

Ordering Part Numbers:

IPX AUTOMATIC IP NETWORK LOSS BACKUP A/B SWITCH INSTRUCTION BOOK IB

Software manual Displays and Dash

B/S/H/ Error codes and service programmes PH

Data sheet GIOD.1 Input/output module with CAN bus. ERP no.: Data sheet GIOD.1 V_3.0

CNC Turning Training CNC MILLING / ROUTING TRAINING GUIDE. Page 1

Permissible ambient temperature Operation Storage, transport

A2, A6. PEK Control panel. Instruction manual

Device Type Manager (DTM) Basic HART

Setting up the DeskCNC controller.

WEA-Base. User manual for load cell transmitters. UK WEA-Base User manual for load cell transmitters Version 3.2 UK

THERMAL ANEMOMETRY ELECTRONICS, SOFTWARE AND ACCESSORIES

Signature and ISX CM870 Electronics

SuperIOr Controller. Digital Dynamics, Inc., 2014 All Rights Reserved. Patent Pending. Rev:

Portal Software GSM-PRO Run LED displays module activity Com LED displays activity on the GSM network GSM-PRO

Model SETR-50 and SETR-51 Trim Tab Control

Manual. IP Sensor and Watchdog IPSW2210. I P S W M a n u a l P a g e 1. Relay Output. Power input. 12VDC adapter LED Indicators. 2 Dry.

Allegion PIM-400/485 and AD-400 Installation Application Note. 1.0 Hardware Requirements. 2.0 Software/Licensing Requirements

Ordering Part Numbers: Universal Signal Converter: USC-CVB Universal Signal Converter with a 4-20mA input and +/- 10V output: USC-CVB225-B10V

CAN BUS INTERFACE. Module Information

Remote monitoring of Crouzet Millenium 3 using Netbiter EasyConnect EC-220 & Netbiter Argos

SenseLink TM. End-Point Controller. Addendum

Transcription:

User s Manual IOB 49 English (en) 3/2007

I Operating Instructions... 5 I General Information... 6 Connecting the IOB 49 to X10 for executing switching functions (milling) or controlling the constant surface speed CSS (turning)... 6 I 1 Execution of Switching Functions... 7 Switching inputs... 7 Switching outputs... 7 I 2 Controlling the Constant Surface Speed (CSS)... 10 Configuration of CSS... 11 CSS operating mode... 12 Activating the DAC output... 13 Connecting the IOB to the inverter of the lathe... 14 I 3 Diagnostics... 15 Switching I/O functions... 15 CSS... 16 HEIDENHAIN IOB 49 3

Operating Instructions HEIDENHAIN IOB 49 5

General Information General Information Connecting the IOB 49 to X10 for executing switching functions (milling) or controlling the constant surface speed CSS (turning) When the IOB 49 is connected to the ND 780, the functionalities described above are available. For information on the installation of the IOB 49 in an electrical cabinet, the connection technology and the wiring, please refer to the Operating Instructions. The Operating Instructions are included with every position display unit, or can be requested from HEIDENHAIN. The position display unit automatically recognizes when an IOB 49 is connected and displays the CSS SETUP option or the SWITCHING OUTPUTS option in the INSTALLATION SETUP menu. These options can be used to configure all functions of the switching unit. 6 I Operating Instructions

I 1 Execution of Switching Functions Switching functions can only be executed when the position display unit is configured for milling applications. If you want to use both the IOB 49 and the KT 130 edge finder at the same time or if you want to transmit measured values via the external switching output, the distribution cable with ID 532 909-01 is required. Switching inputs The IOB 49 provides three inputs that are used to zero the actual value of the assigned axis. A low-to-high transition at the input causes the value for that axis to be set to zero. Switching outputs The switching outputs consist of eight (integrated) relays that are activated depending on the position. The relays can be configured to activate when a position display reaches a specific value or within a specified range of zero. The ninth output relay indicates readiness. Select SWITCHING OUTPUTS from the INSTALLATION SETUP menu to open the SWITCHING OUTPUTS table in which the configuration of the eight outputs is stored. If you want to change the configuration of an output, select it with the arrow keys and press ENTER to confirm your selection. This opens the OUTPUT SETTINGS form in which you define the switching conditions. To reset a relay, select the relay in the table and press the CLEAR RELAY soft key. I 1 Execution of Switching Functions Fig. I.1 HEIDENHAIN IOB 49 7

I 1 Execution of Switching Functions The CONDITION field is used to assign an axis to the output and to specify whether the axis position is an actual-value or distance-to-go position. You also specify the position display value at which the relay is activated, and the required condition. The POINT/RANGE field is used to define whether the conditions refers to a point on the axis or refers to a range about zero. The OUTPUT field is used to specify the relay operation when the switching condition is met. When the condition is met, the relay is turned OFF or ON. Fig. I.2 OUTPUT SETTINGS form Fig. I.3 Possible switching states of the relays 8 I Operating Instructions

In PULSED mode, the relay is activated (ON or OFF) for a specific period of time. After the period has timed out, the relay is deactivated. The pulse time is 0.1 to 999 seconds. The time period begins whenever the switching condition transitions from FALSE to TRUE. If the switching conditions transitions to TRUE before the period has timed out, the timer will start over. The switching functions cannot be used for coupled axes or for axes with backlash compensation. Relay Condition Fig. I.4 CONTINUOUS mode Relay Condition Fig. I.5 PULSED mode I 1 Execution of Switching Functions HEIDENHAIN IOB 49 9

I 2 Controlling the Constant Surface Speed (CSS) I 2 Controlling the Constant Surface Speed (CSS) In CSS mode, a constant surface cutting speed can be maintained on a lathe. The following functions are available: CSS mode: The DAC output signal provides constant surface speed by adjusting the spindle speed as the diameter (radius) of the workpiece changes. Direct entry of spindle speed: The DAC output signal sets the spindle speed based on the value entered via the numeric keypad. Speed limits: The user may set a safe operating range (minimum and maximum speeds) for spindle speed. Gear selection: Three different gears can be specified for varying the relation between the actual speed and the DAC output signal. 10 I Operating Instructions

Configuration of CSS The spindle control configuration parameters are set up in the INSTALLATION SETUP menu. Select the CSS SETTINGS parameter to open the associated input form. The CSS ON/OFF CONTROL field is used to specify whether the CSS mode is operated by soft key or by an external hardware signal. The current gear may be selected by local control (MANUAL via CSS / DIRECT RPM in the JOB SETUP menu) or remote control (EXTERNAL; via switches in the machine gear). This is defined in the CSS GEAR SELECT field. The VOLTAGE OFFSET function is used to adjust for any inherent offset in the DAC signal. Using a voltmeter, measure the actual voltage at the DAC output. Press INCREASE or DECREASE to adjust the offset until the output is 0 V. The offset range is limited to 0 to 50 (approximately 0 to 122 mv). The VOLTAGE / RPM fields are used to establish the relationship between the DAC output signal (0 to 10 V) and the spindle speed. The minimum and maximum limits for each gear are entered. If the position display of the third axis is configured to be used for the spindle speed, the rpm in the SETTING field can be set to the current spindle speed by pressing the TEACH soft key. To set a specific spindle speed, the DAC output S Out uses this linear relationship to determine the corresponding output voltage V Out : V Out = 10 (S Out - S 0 ) / ( S 10 - S 0 ) + V Offset Press ENTER to save the parameters and exit the input form. Press the C key to exit without saving the changes you made. Fig. I.6 Fig. I.7 CSS SETTINGS (1) form CSS SETTINGS (2) form I 2 Controlling the Constant Surface Speed (CSS) HEIDENHAIN IOB 49 11

I 2 Controlling the Constant Surface Speed (CSS) CSS operating mode The operating parameters are set in the CSS / DIRECT RPM form. Press the CSS SETUP soft key to open the form or select the parameter from the JOB SETUP menu. The SETTINGS field is used to select the mode of operation and the control settings. The spindle is controlled by selecting CSS or by entering the spindle speed directly. The values to be entered depend on the selected option. If CSS was selected to maintain a constant surface speed, the surface speed entered with the numeric keys is maintained. As the diameter of the part changes, the spindle speed will be adjusted. To set a specific spindle speed, select DIRECT / RPM and enter the value with the numeric keypad. If the position display of the third axis is configured to be used for the spindle speed, the rpm in the SETTING field can be set to the current spindle speed by pressing the TEACH soft key. Select OFF when spindle control is not needed. The GEAR SELECTION field is used to manually enter the operating gear with the numeric keypad. If the gear control parameter in INSTALLATION SETUP is set to EXTERNAL, the field will show the current gear selection based on the external inputs. The field can then not be selected and is skipped. The LIMITS field is used to establish the minimum and maximum limits of the controlled spindle speed. When operating in the CSS or DIRECT RPM modes, the DAC output will not be set to a speed above or below these limits. If the position display of the third axis is configured to be used for the spindle speed, the rpm in the SETTING field can be set to the current spindle speed by pressing the TEACH soft key. Press ENTER to save the parameters and exit the input form. Press the C key to exit without saving the changes you made. The settings will be lost when the ND 780 is switched off. Fig. I.8 Form in which the speed limits are defined 12 I Operating Instructions

Activating the DAC output After selecting the operating mode and entering its parameters, the DAC output must be enabled to begin controlling the spindle. The output to the spindle inverter drive is an open loop signal. The system does not monitor the actual spindle speed. The output signal is based solely on the inverter's speed input versus the input voltage profile. Depending on the operating mode selected, the RPM or CSS soft key is displayed on the fourth page of the soft key menu. If the current state indicated on the soft key is ON, the DAC output is active. Press the soft key to OFF to disable the spindle control. If CSS is active, the CSS icon appears next to the X-axis display. If the entered surface speed or rpm cannot be maintained because the speed is outside the range for the current gear or outside the limits from the CSS/RPM SETTINGS form, an arrow will appear after the CSS icon ( or ). The direction of the arrow indicates whether the speed is at the upper or lower limit. The soft key to enable CSS or RPM control will not appear if the operating mode is set to OFF. If the CSS control parameter under INSTALLATION SETUP is set to EXTERNAL, the CSS or RPM operation cannot be controlled by soft key. The soft key will show the current state, but pressing it will have no effect. The SPEED + and SPEED soft keys are used to increase or decrease the current surface speed or spindle speed. The value is increased or decreased by 5% each time the soft key is pressed. I 2 Controlling the Constant Surface Speed (CSS) HEIDENHAIN IOB 49 13

I 2 Controlling the Constant Surface Speed (CSS) Connecting the IOB to the inverter of the lathe Fig. I.9 CSS I/0 X103 9 OUT 789 X103 10 OUT 7 X103 11 OUT 8 X102 1 IN 0 X102 2 IN 0+ X102 3 IN 1 X102 4 IN 1+ X102 5 IN 2 X102 6 IN 2+ X102 7 IN 3 X102 8 IN 3+ X102 11 DAC OUT X102 12 COMMON TURNING APPLICATION 1 Automatic CSS/Pot Control GEAR 1 GEAR 2 GEAR 3 + 12 24 VDC 100 ma MANUAL RPM Example of gear detection and switching to manual spindle speed control CSS I/0 OUT 789 OUT 7 OUT 8 X103 9 X103 10 X103 11 X102 1 IN 0 IN 0+ X102 2 IN 1 X102 3 IN 1+ X102 4 IN 2 X102 5 IN 2+ X102 6 IN 3 X102 7 IN 3+ X102 8 DAC OUT COMMON X102 11 X102 12 TURNING APPLICATION 2 Manual CSS/Pot Control V ref.+ Pot on machine V ref. FWD REV CSS/pot Selector OFF FWD REV OFF INVERTER INPUT+COMMON FORWARD REVERSE ANALOG SUPPLY ANALOG INPUT ANALOG COMMON INVERTER INPUT+COMMON FORWARD REVERSE ANALOG INPUT ANALOG COMMON Fig. I.10 Example of switching to manual spindle speed control 14 I Operating Instructions

I 3 Diagnostics When the IOB 49 is connected to the ND 780, the DIAGNOSTICS menu under INSTALLATION SETUP provides further diagnostic possibilities. The information available varies depending on the configuration of the system (CSS or switching I/O functions). Switching I/O functions The SWITCHING I/O DIAGNOSTICS shows the status of the communication via the CAN bus and the state of the switching inputs and outputs to provide monitoring of the switching functions. The CAN STATUS field shows the state of the bus communication between the position display unit and the IOB 49. The status information has the following meaning: I 3 Diagnostics Information NOT PRESENT NOR CAL Wen Wds Wto Tx Rx Meaning No communication with hardware Communication normal operation Communication Hardware in calibration mode Watchdog active Watchdog inactive Watchdog time-out Data is transmitted to hardware Data is received by hardware The SWITCHING I/O field shows the state of the inputs and the switch position of the relays. All currently active inputs (1 to 3) are shown in the ON field. All currently active relay outputs (1 to 9) are shown in the OFF field. The CALIBRATE soft key is used to re-synchronize the communication with the IOB 49. This, however, is only required if the module is not detected upon power on. HEIDENHAIN IOB 49 15

I 3 Diagnostics CSS CSS DIAGNOSTICS shows the status of the communication via the CAN bus and the state of the DAC output to provide monitoring of the interfaces for operation with constant surface speed. The state of the switching inputs and outputs is also shown. The CAN STATUS field shows the state of the bus communication between the position display unit and the IOB 49. The status information has the following meaning: Information NOT PRESENT Meaning No communication with hardware NOR CAL Wen Wds Wto Tx Rx Communication normal operation Communication Hardware in calibration mode Watchdog active Watchdog inactive Watchdog time-out Data is transmitted to hardware Data is received by hardware The DAC OUTPUT field shows the current value of the transmitted voltage. The value is between 0 and 4095, which corresponds to a voltage of 0 to 10 V at X102-11. The corresponding CSS icon will be displayed if the spindle speed is at the upper or lower limit ( or ). The CSS INPUT/OUTPUT field shows the state of the switching inputs and relay outputs. 16 I Operating Instructions

The status information has the following meaning: Information about the inputs EXT G1 G2 G3 Meaning External switch is active (X102-12) Switch for gear 1 is active (X102-3,4) Switch for gear 2 is active (X102-5,6) Switch for gear 3 is active (X102-7,8) I 3 Diagnostics Information about the outputs POT DAC Meaning Potentiometer relay is active (X103-10) DAC output relay is active (X102-11) The CALIBRATE soft key is used to re-synchronize the communication with the IOB 49. This, however, is only required if the module was not detected at switch-on. HEIDENHAIN IOB 49 17

A Activating the DAC output... 13 C Configuration of CSS... 11 Controlling the constant surface speed (CSS)... 10 CSS... 16 CSS operating mode... 12 Index D Datums... 6 Diagnostics... 15 E Execution of switching functions... 7 R Relay status... 8 S Switching I/O functions... 15 Switching inputs... 7 Switching outputs... 7 HEIDENHAIN IOB 49 19

DR. JOHANNES HEIDENHAIN GmbH Dr.-Johannes-Heidenhain-Straße 5 83301 Traunreut, Germany { +49 (8669) 31-0 +49 (8669) 5061 E-Mail: info@heidenhain.de www.heidenhain.de Ve 00 627 053-21 3/2007 pdf Printed in Germany Subject to change without notice