SIMATIC. ET 200S Distributed I/O System Digital Electronic Module 8DI DC24V SOURCE INPUT (6ES7131-4BF50-0AA0) Preface. Properties 1.

Similar documents
SIMATIC. ET 200S distributed I/O Digital electronic module 8DI DC24V (6ES7131-4BF00-0AA0) Preface. Properties 1. Diagnostics 2.

SIMATIC. ET 200S distributed I/O Digital electronic module 8DO DC24V/0.5 A (6ES7132-4BF00-0AA0) Preface. Properties 1. Diagnostics 2.

SIMATIC. ET 200S distributed I/O 2AO I ST analog electronic module (6ES7135-4GB01-0AB0) Preface. Properties 1. Parameters 2.

SIMATIC. ET 200S distributed I/O 2AI U ST analog electronic module (6ES7134-4FB01-0AB0) Preface. Properties 1. Parameters 2.

CPU PN/DP: Configuring an ET. 200S as PROFINET IO device SIMATIC. PROFINET CPU PN/DP: Configuring an ET 200S as PROFINET IO device

SIMATIC S Getting Started for First Time Users. Order No.: 6ZB5310-0NC02-0BA0 04/2007 A5E

Validity 1. Improvements in STEP 7 2. Improvements in WinCC 3 SIMATIC. Readme. Programming and Operating Manual

Validity 1. Installation 2 SIMATIC. WinCC flexible Tag simulator Update 1. Readme

DANGER indicates that death or severe personal injury will result if proper precautions are not taken.

SIMATIC NET. CP AS-Interface Master B C. Preface Contents. Technical Description and Installation Instructions Interface to the User Program

DI 16x24VDC HF Digital Input Module (6ES7521-1BH00-0AB0) SIMATIC. S7-1500/ET 200MP DI 16x24VDC HF Digital Input Module (6ES7521-1BH00-0AB0) Preface

Modular I/O System Analog and Digital Interface Modules

Creating the project and hardware. TIA Portal. SIMATIC Creating the project and hardware. Introduction to the TIA Portal 1. Creating a project

SIMATIC. WinCC V7.0. Getting started. Getting started. Welcome 2. Icons 3. Creating a project 4. Configure communication 5

Documentation for. KL2602 and KL2622. Two-channel Relay Output Terminals for 230 V AC / 30 V DC. Version: 1.4 Date:

SIMATIC. S7 300 PLC CPU 317T-2 DP: Controlling a virtual axis. Introduction. Preparation. Learning units 3. Further information 4.

SIMATIC HMI. WinCC flexible 2008 Getting Started - First-Time Users Getting Started. Printout of the Online Help 06/2008 A5E

Specifications for EM VDC 4 In/4 Out and EM VDC 4 In/4 Relay Out

CompactLogix Power Supplies Specifications

SIMATIC. ET 200S distributed I/O IM151-1 STANDARD interface module (6ES7151-1AA05-0AB0) Preface. Properties 1. Parameters 2.

DANGER indicates that death or severe personal injury will result if proper precautions are not taken.

Creating the program. TIA Portal. SIMATIC Creating the program. Loading the block library. Deleting program block Main [OB1] Copying program blocks

SIMATIC. S7-300 and M7-300 Programmable Controllers Module Specifications. Preface, Contents. General Technical Specifications. Power Supply Modules

Automation Unit TM 1703 ACP Flexible automation and telecontrol

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q R0001

SINAMICS drives SINAMICS DCM. DC converters from 6 kw to 2500 kw for variable-speed direct-current drives. Load-balanced control application

S7-400H SIMATIC. Fault-tolerant systems S7-400H. Preface 1 Fault-tolerant automation systems. S7-400H setup options 3.

Configuration limits for products of the SIMATIC NET PC Software V12 SIMATIC NET. Configuration limits for products of the SIMATIC NET PC Software V12

Patch management and security. updates SIMATIC. Process Control System PCS 7 Patch management and security updates. Preface 1

Visualization SIMATIC. Visualization. Present sample project. HMI configuration. Insert HMI device from libraries 3. Configuring HMI connection 4

WinCC Runtime Professional Readme SIMATIC HMI. WinCC V11 SP1. Readme WinCC Runtime Professional. Special considerations for Windows 7.

Digital input modules

Information Server Documentation SIMATIC. Information Server V8.0 Update 1 Information Server Documentation. Introduction 1. Web application basics 2

Fieldbus slave modules with I/Os, DIO

SIMATIC. PC Adapter USB. Preface, Contents Properties of the PC Adapter USB 1. Package Components

Validity 1. Improvements in STEP 7 2. Improvements in WinCC 3. Simatic. Readme. Readme

ZC-24DO CANopen I/O Module: 24 Digital Outputs

SIMATIC. SM 335 High-Speed Analog Input/Output Module for the SIMATIC S7-300

SIMATIC. SIMATIC Logon. User management and electronic signatures. Hardware and Software Requirements. Scope of delivery 3.

Part 1: User information SIMATIC ET 200B Distributed I/O Station Manual Part 2: Reference information Appendices EWA 4NEB c Edition 04

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC A - M8 connector

Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs

SIMATIC. Process Control System PCS 7 Configuration Symantec Endpoint Protection (V12.1) Preface 1. Virus scanner administration 2.

SIMATIC NET. Functions (FC) and function blocks (FB) for SIMATIC NET S7 CPs. Preface. Overview and general information on working with FCs and FBs

IBS IP KIS A. Data Sheet INTERBUS-S. Digital I/O Module

What ensures easy and fast wiring?

DRM75A 230V 20/100A DIN rail single phase two wire energy meter

SIMATIC NET. AS-Interface - Introduction and Basics A B. Preface, Contents

Short-circuit current rating (SCCR) of. industrial control panels. NEC Article 409 and UL 508A

SIMATIC. Open TCP/IP Communication via Industrial Ethernet. Contents Open TCP/IP Communication via Industrial Ethernet 1. Index.

Brake module AX5021. Documentation. Please read this document carefully before installing and commissioning the brake module!

Safety technique. Emergency stop module BO 5988 safemaster

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

Installation guide H A. HSI hardwired system interface

ADM1TE 5/30A DIN rail single phase two wire energy meter

Original instructions Tina 3A/Aps Adaptor unit

Cross-beam scanning system to detect slim objects. 100 mm in

Performing an automated installation

Tina 2A/B Adaptor unit

The CP FO provides access to different communication services of the PROFIBUS bus system:

SIMATIC NET Industrial Ethernet switches MM900 media modules for SCALANCE XR-500M

S SIMATIC S Welcome. Automation task. Hardware section 2. Software section 3. Security. Getting Started 05/2014 A5E AC

COMOS. Lifecycle COMOS Snapshots. "COMOS Snapshots" at a glance 1. System requirements for installing "COMOS Snapshots" Database management 3

4 non-safe digital I/O channels 2 IO-Link Master V1.1 slots. Figure 1. Figure 2. Type code. TBPN-L1-FDIO1-2IOL Ident no

EE-SPY801/802. Photomicrosensors for detecting wafer-carrier mounting. Wafer-carrier Mounting Photomicrosensors. Ordering Information.

3500/62 Process Variable Monitor

Safety Relays ESM/ESM-F

PCS0100en Persy Control Services B.V. Netherlands

CP Page 1342 Mar 2008 Siemens ITS

Contents. Document information

Model 1756 Test Lead Kit

The CP provides access to different communication services of the PROFIBUS bus system:

SIMATIC. S7-300 Programmable Controller Installation and Hardware. Preface, Contents. Product Overview 1. Mechanical Configuration 2

2 Counter Module SIMATIC. S7-300 FM Counter module. Preface. Product Overview. How the FM Counts 2. Installing and Removing the FM 350-

mecotron Safety relay ESTOP-2 For emergency stop monitoring

PROFINET CPU 314C-2 PN/DP, PN/DP, PN/DP, PN/DP: Configuring the PROFINET interface

MCR1900 Media Converter 19-Slot Chassis

TX OPEN RS232/485 module

MINI MCR-SL-R-UI(-SP)

User Manual Revision English

Siemens AG Fieldbus solutions with the SIMATIC PCS 7 distributed control system. Brochure April 2010 SIMATIC PCS 7. Answers for industry.

EPM3. Phase Sequence and Motor Rotation Tester. Users Manual

C13 User Manual Document ID: 2CMC486004M0201 Revision: A

Instruction book IQAN-MDM. Publ. no. HY /UK Edition June, 2007

5SV Residual Current Protective Devices

LOGO! LOGO! App V.10. LOGO! app 1. Making basic settings and establishing a connection to LOGO! Using the device overview 3. Creating controls 4

CQM1-SF200/CS1W-SF200

Training Document for Comprehensive Automation Solutions Totally Integrated Automation (T I A) MODUL E04

DANGER indicates that death or severe personal injury will result if proper precautions are not taken.

SITOP UPS1600 / UPS1100. SITOP power supply SITOP UPS1600 / UPS1100. Overview. Safety information. Description, device design, dimension drawing 2

Safety automation solutions

Square D Clipsal DIN-Rail Four-Channel Auxiliary Input Unit

Data Sheet FUJITSU Storage ETERNUS LT260 Tape System

ABB Drives. User s Manual. Pulse Encoder Interface Module RTAC-01

User Manual Revision English

User Manual Revision English

InHome Water Leak Detection Package

User Manual Revision English

Operating Instructions (Compact) Edition 02/2006

6ES7314-6CG03-0AB0. Supply voltages Rated value 24 V DC Yes permissible range, upper limit (DC) circuit breaker type B, min. 4 A

Transcription:

Preface Properties 1 SIMATIC Diagnostics 2 ET 200S Distributed I/O System Digital Electronic Module 8DI DC24V SOURCE INPUT (6ES7131-4BF50-0AA0) Manual 07/2007 A5E01077465-01

Safety Guidelines This manual contains notices you have to observe in order to ensure your personal safety, as well as to prevent damage to property. The notices referring to your personal safety are highlighted in the manual by a safety alert symbol, notices referring only to property damage have no safety alert symbol. These notices shown below are graded according to the degree of danger. DANGER indicates that death or severe personal injury will result if proper precautions are not taken. WARNING indicates that death or severe personal injury may result if proper precautions are not taken. CAUTION with a safety alert symbol, indicates that minor personal injury can result if proper precautions are not taken. CAUTION without a safety alert symbol, indicates that property damage can result if proper precautions are not taken. NOTICE Qualified Personnel Prescribed Usage Trademarks indicates that an unintended result or situation can occur if the corresponding information is not taken into account. If more than one degree of danger is present, the warning notice representing the highest degree of danger will be used. A notice warning of injury to persons with a safety alert symbol may also include a warning relating to property damage. The device/system may only be set up and used in conjunction with this documentation. Commissioning and operation of a device/system may only be performed by qualified personnel. Within the context of the safety notes in this documentation qualified persons are defined as persons who are authorized to commission, ground and label devices, systems and circuits in accordance with established safety practices and standards. Note the following: Disclaimer of Liability WARNING This device may only be used for the applications described in the catalog or the technical description and only in connection with devices or components from other manufacturers which have been approved or recommended by Siemens. Correct, reliable operation of the product requires proper transport, storage, positioning and assembly as well as careful operation and maintenance. All names identified by are registered trademarks of the Siemens AG. The remaining trademarks in this publication may be trademarks whose use by third parties for their own purposes could violate the rights of the owner. We have reviewed the contents of this publication to ensure consistency with the hardware and software described. Since variance cannot be precluded entirely, we cannot guarantee full consistency. However, the information in this publication is reviewed regularly and any necessary corrections are included in subsequent editions. Siemens AG Automation and Drives Postfach 48 48 90327 NÜRNBERG GERMANY Ordernumber: A5E01077465-01 P 08/2007 Copyright Siemens AG 2007. Technical data subject to change

Preface Purpose of the manual This manual supplements the ET 200S Distributed I/O System Operating Instructions. General functions for the ET 200S are described in the ET 200S Distributed I/O System Operating Instructions. The information in this document along with the operating instructions enables you to commission the ET 200S. Basic knowledge requirements To understand these operating instructions you should have general knowledge of automation engineering. Scope of the manual This manual applies to this ET 200S module. It describes the components that are valid at the time of publication. Recycling and disposal Thanks to the fact that it is low in contaminants, this ET 200S module is recyclable. For environmentally compliant recycling and disposal of your electronic waste, please contact a company certified for the disposal of electronic waste. Additional support If you have any questions relating to the products described in these operating instructions, and do not find the answers in this document, please contact your local Siemens representative. http://www.siemens.com/automation/partner The portal to our technical documentation for the various SIMATIC products and systems is available at: http://www.siemens.com/automation/simatic/portal The online catalog and ordering system are available at: http://www.siemens.com/automation/mall Manual, 07/2007, A5E01077465-01 3

Preface Training center We offer courses to help you get started with the ET 200S and the SIMATIC S7 automation system. Please contact your regional training center or the central training center in D -90327, Nuremberg, Germany. Phone: +49 (911) 895-3200. http://www.siemens.com/sitrain Technical Support You can reach technical support for all A&D projects using the support request web form: http://www.siemens.com/automation/support-request Phone: + 49 180 5050 222 Fax: + 49 180 5050 223 For more information about our technical support, refer to our Web site at http://www.siemens.de/automation/service Service & Support on the Internet In addition to our documentation services, you can also make use of our comprehensive online knowledge base on the Internet. http://www.siemens.com/automation/service&support There you will find: Our Newsletter, which constantly provides you with the latest information about your products. The right documentation for you using our Service & Support search engine. The bulletin board, a worldwide knowledge exchange for users and experts. Your local contact for Automation & Drives in our contact database. Information about on-site services, repairs, spare parts. Lots more can be found on our "Services" pages. 4 Manual, 07/2007, A5E01077465-01

Table of contents Preface... 3 1 Properties... 7 1.1...7 2 Diagnostics... 13 2.1 Diagnostics using LED display...13 Index... 15 Manual, 07/2007, A5E01077465-01 5

Table of contents 6 Manual, 07/2007, A5E01077465-01

Properties 1 1.1 Digital Electronic Module 8DI DC24V SOURCE INPUT (6ES7131-4BF50-0AA0) Properties Digital electronic module with eight inputs Source input 24 VDC nominal input voltage Suitable for connecting 2-wire sensors Supports isochronous mode Requirements for operation It is possible to operate the Digital Electronic Module 8DI DC24V SOURCE INPUT with the following interface module versions (specified order number or higher). Interface modules not listed in the table are not subject to any constraints. Interface module Order number (or higher) Firmware version (or higher) IM 151-1 STANDARD 6ES7151-1AA03-0AB0 --- IM 151-1 FO STANDARD 6ES7151-1AB02-0AB0 --- IM 151-1 HIGH FEATURE 6ES7151-1BA02-0AB0 --- IM 151-3 PN IM 151-3 PN HIGH FEATURE IM 151-3 PN FO 6ES7151-3AA20-0AB0 6ES7151-3BA20-0AB0 6ES7151-3BB21-0AB0 V4.0.1 Manual, 07/2007, A5E01077465-01 7

Properties 1.1 General terminal assignment Note The A4, A8, A3, and A7 terminals are only available at specified terminal modules. Terminal assignment for 8DI DC24V SOURCE INPUT (6ES7131-4BF50-0AA0) Terminal Assignment Terminal Assignment Notes 1 DI0 5 DI1 2 DI2 6 DI3 3 DI4 7 DI5 DIn: Input signal, Channel n AUX1: M chassis ground (from the power module, for example) or potential bus (available for use up to 230 VAC) 4 DI6 8 DI7 A4 AUX1 A8 AUX1 A3 AUX1 A7 AUX1 Available terminal modules Available terminal modules for 8DI DC24V SOURCE INPUT (6ES7131-4BF50-0AA0) TM-E15C26-A1 (6ES7193-4CA50-0AA0) TM-E15S26-A1 (6ES7193-4CA40-0AA0) TM-E15N26-A1 (6ES7193-4CA80-0AA0) TM-E15C24-01 (6ES7193-4CB30-0AA0) TM-E15S24-01 (6ES7193-4CB20-0AA0) TM-E15N24-01 (6ES7193-4CB70-0AA0) Spring terminal Screw-type terminal Fast Connect Sample connections 1-wire 8 Manual, 07/2007, A5E01077465-01

Properties 1.1 2-wire connection The following configuration example shows a 2-wire connection with the 8DI DC24V SOURCE INPUT electronic modules. You require further terminals so that sufficient terminals are available for the chassis ground connection M when the TM-E15S26-A1 terminal modules are used. In the example, this is achieved through the Add-On Terminal TE-U120S4x10. Terminal modules of the same height over a minimum width of 120 mm must be present for each add-on terminal. You can naturally also use other terminals for this configuration (for example, ET 200S potential distribution module 4POTDIS). 2 3 4 1 5 6 1 2 3 4 5 6 Terminal Module TM-P15S23-A0 Power Module PM-E DC24V Electronic Module 8DI DC24V SOURCE INPUT Terminal Module TM-E15S26-A1 Sensor in 2-wire connection Add-On Terminal TE-U120S4x10 Manual, 07/2007, A5E01077465-01 9

Properties 1.1 Block diagram Figure 1-1 Block diagram of the 8DI DC24V SOURCE INPUT 10 Manual, 07/2007, A5E01077465-01

Properties 1.1 Technical specifications of 8DI DC24V SOURCE INPUT (6ES7131-4BF50-0AA0) Dimensions and weight Width (mm) 15 Weight Approx. 35 g Module-specific data Supports isochronous mode Yes Number of inputs 8 Cable length Unshielded Max. 600 m Shielded Max. 1000 m Parameter length 3 bytes Voltages, currents, potentials Rated supply voltage (from the power module) 24 VDC Reverse polarity protection Yes Electrical isolation Between the channels No Between the channels and backplane bus Yes Permissible potential difference Between the different circuits 75 VDC / 60 VAC Insulation test voltage 500 VDC Current consumption From backplane bus Max. 10 ma From supply voltage Dependent on the sensor Power dissipation of the module Typ. 1.2 W Status, interrupts, diagnostics Status display Green LED per channel Diagnostics function No Data for selecting a sensor Input voltage Rated value 24 VDC For signal "1" -15 V to -30 V; reference potential is L+ For signal "0" 30 V to -5 V; reference potential is L+ Input current For signal "1" Typ. 6 ma (at 24 V) Input delay For "0" to "1" Typ. 3 ms For "1" to "0" Typ. 3 ms Input characteristic curve According to IEC 61131, Type 1 Connection of 2-wire BEROs Supported Permitted bias current Max. 1.5 ma Manual, 07/2007, A5E01077465-01 11

Properties 1.1 12 Manual, 07/2007, A5E01077465-01

Diagnostics 2 2.1 Diagnostics using LED display LED display 1 1 Status display for input/output status (green) Status displays Event (LEDs) Cause Remedy 1 5 2 6 3 7 4 8 On Input/output at Channel 0 activated. On Input/output at Channel 1 activated. On Input/output at Channel 2 activated. On Input/output at Channel 3 activated. On Input/output at Channel 4 activated. On Input/output at Channel 5 activated. On Input/output at Channel 6 activated. On Input/output at Channel 7 activated. Manual, 07/2007, A5E01077465-01 13

Diagnostics 2.1 Diagnostics using LED display 14 Manual, 07/2007, A5E01077465-01

Index B Basic knowledge requirements, 3 Block diagram, 10 C Configuration example for 2-wire connection, 9 T Technical specifications, 11 Technical Support, 4 Terminal assignment, 8 Terminal modules, 8 Training center, 4 D Disposal, 3 I Internet Service & Support, 4 L LED display, 13 P Properties, 7 R Recycling, 3 Requirements for operation, 7 S Scope Manual, 3 Service & Support, 4 Status displays, 13 Manual, 07/2007, A5E01077465-01 15

Index 16 Manual, 07/2007, A5E01077465-01