Dry-type transformers Mini power centers. Less is more...

Similar documents
HPS Universal. Single and Three Phase Potted. Buck-Boost Transformers. Buck-Boost Applications & Standard Specification... 80

Mini Power-Zone Unit Substation Product Description. Product Description. Features. Typical Applications

Metallic and Non-Metallic Air Conditioning Disconnects. A Complete Family of. Disconnects with Exclusive Time Saving Features

Mini Power-Zone Unit Substation

Secondary Unit Substations

Single Phase Three Phase Single Phase Export Model Transformers Single Phase Buck and Boost Transformers Stainless Steel Enclosed Transformers

Low Voltage Transformers Sealed, General Purpose, Dry Type

Bolted contact switches. Pringle switches

Distribution Dry Type Transformers

BERTHOLD ELECTRIC GENERATOR CONNECTION CABINET

8146/5 Series Breaker Panelboards

Submit shop drawings for equipment provided under this section Shop drawings shall indicate:

HVL 5 38 kv Load Interrupter Switchgear. The Standard for Performance, Protection and Dependability

DC disconnects for solar photovoltaic installations. Connecting the. power of the sun

Decision-Maker Paralleling System. Power Distribution Switchboards and Circuit Breakers. Standard Features

12VDC MAGNETIC LED DIMMABLE POWER SUPPLIES SPEC SHEET DIGEST

MCC Ratings. Voltage Rating

Type 1, 3, & 3R Enclosures

2a. IEM Indoor Metal Clad Medium Voltage Switchgear 15KV a. Section INDOOR METAL CLAD MEDIUM VOLTAGE SWTICHGEAR (Std.

Explosion-Proof Electric Unit Heaters

MEDIUM VOLTAGE CE-BF SWITCHBOARDS. UP TO 40.5 kv. CE - BF - C - en - REV

ASCO SERIES 185 Power Transfer Switches

Learning Module 13: Panelboards and Switchboards. 101 Basic Series

How To Test A Power Switch On A Power Supply

Unit substation solutions with type SIMOSEC primary switches quick reference guide E50001-F710-A389-X-4A00. Answers for energy.

CAT ATC POWER BREAKER & POWER CASE SWITCH AUTOMATIC TRANSFER SWITCH

12V Dimmable Driver EL-TMDRVR

METER REQUIREMENTS GENERAL REQUIREMENTS SECTION D

Cable/Conduit Conversion

All work must conform to the National Electric Code, latest edition, and all other applicable codes and regulations.

LVA Take Offs in Bid Manager

FFI. Advances in Medium and Low Voltage Power Distribution ESS Metron Expo and Technical Seminars. Presented By: Greg Pelster & Robert Schmid

D-13. temporary / mobile power. for harsh & hazardous (classfied) locations. Construction Demolition Maintenance Turnarounds Shutdowns

Power Outlet Panels. Product Guide

LIEBERT VNSA Installation Sheet

GE Power Controls. MiniFORM Switchboards

Distribution Dry Type Transformers

Contractors Guide Central Inverter System Installation

Connecting the Power of the Sun. DC Disconnects for Solar Photovoltaic Installations. DC disconnects for. solar photovoltaic installations

5 Non-Ventilated Automation Transformers

STB Series Enclosures

ECOCIAT. Domestic hot water heat recovery unit

UNIVERSITY OF WASHINGTON Facilities Services Design Guide. Electrical. Switchboards. Basis of Design. Design Evaluation

ELECTRIC UTILITY SERVICE EQUIPMENT REQUIREMENTS COMMITTEE, EUSERC

Pump Specifications 250 Series Submersible Sump / Effluent Pump 2 Solids handling

CABINET OPTIONS AND DESIGNATORS

Buck - Boost Transformers

Section 10 Electric Switchboards: 0 Through 600 Volts

Engineers Edge, LLC PDH & Professional Training

Continuous Power... Continuous Protection

ELECTRIC METERING COMMERCIAL & INDUSTRIAL

Equipment. Metering. Metering Equipment 1. Contents

Modular Systems wind portfolio overview Power Collection and Grid Connection products

PRODUCT GUIDE. SL Medium Voltage IEC Vacuum Contactors

ELECTRICAL SERVICE REQUIREMENTS FOR MOBILE HOME DEVELOPMENTS

Medium Voltage Motor Control Assemblies

SERVICE ENTRANCE - UNDERGROUND Single & Three Phase 200, & 320/400 Amp

SPECIFICATIONS FOR THE INSTALLATION OF FIRE ALARM SYSTEMS, SPRINKLER SYSTEMS, AND MASTER BOXES IN THE POQUONNOCK BRIDGE FIRE DISTRICT

CAB LCAB HACAB RMP/AMP CC CY/YY RVP CUSTOM CU

ASSEMBLED SOCKET-COMBINATIONS

This section applies to the design and installation of transformers.

Roped Hydraulic Residential Elevator Specifications

Dialight. Vigilant LED High Bay - UL for Indoor and Outdoor Industrial Applications

IRRIGATION PUMPING Table of Contents - Section 900

Residential/Commercial Gas Condensing High Efficiency Tankless Water Heaters

SHORE POWER. Safely Connecting Ships to Shore SAFETY QUALITY INNOVATION VALUE CUSTOMER SERVICE

SWITCHGEAR SOLUTIONS FOR MISSION CRITICAL APPLICATIONS. Presented by SAI Advanced Power Solutions

Scepter PVC Molded Junction Boxes

Automatic Door Selection Guide

FLB Series Circuit Breakers and Enclosures

Installation Instructions

MEDIUM AND HIGH VOLTAGE CAPACITORS, CAPACITOR BANKS AND SYSTEMS

Vigilant LED High Bay for Indoor and Outdoor Industrial Applications

Installation. Smart-UPS VT MGE Galaxy Maintenance Bypass Panel kva 400 V

TERMINATION ENCLOSURE OPTIONS

5 Non-Ventilated Automation Transformers

Generator DoCKInG StatIonS

Sample - No Commercial Use

Specification Guide. for RVAC. Direct Replacement. AC Medium Voltage. Circuit Breakers

InstaPATCH ZERO Solution Guide

SOLAR PV STANDARD ELECTRICAL PLAN Microinverter Systems for Single Family Dwellings

F-Series Camera Mounting Accessories

BROWACOM PRODUCTS. Our web-pages can be found from:

Transformer Questions & Answers

Installation. Smart-UPS VT and MGE Galaxy Maintenance Bypass Panel with Power Distribution (wall-mount) kva 208 V

Cluster Box Units. (CBU s) 3300 Series CBU Door Sizes. Fully Integrated Parcel Lockers CLUSTER BOX UNITS FRONT LOADING. continued on pages 7-11

Primary and Secondary Electrical Distribution Systems

Temporary Power Outlet Panels. Selection and Application Guide.

Pump Specifications 405 Series Commercial Drain Pump (High-Temp) 2 Solids handling

DuroSite TM High Bay Lighting

Switchboard system. NorLine 800

600 Volt Class Transformers

BUILDERS AND CONTRACTORS GUIDE FOR ELECTRIC SERVICE

READ THIS MANUAL BEFORE PROCEEDING WITH THE INSTALLATION. FAILURE TO FOLLOW THE INSTALLATION INSTRUCTIONS MAY VOID YOUR WARRANTY!

6 Buck Boost Transformers

Motor Accessories. C-Face Kits for Field Conversion NEMA AC Motors

Square D Safety Switches

LV MCC LOW VOLTAGE SWITCHGEAR MOTOR CONTROL CENTRE PRODUCT GUIDE

DRY TYPE TRANSFORMER

3. TYPES OF SERVICE AVAILABLE. 3.1 Scope

Transcription:

Dry-type transformers Mini power centers Less is more...

Exclusive 3-in-1 design Significant savings in cost and space plus quicker installation. Three individual components combined into a single unit. Contemporary electrical distribution systems are required to do more in less space, while at the same time being cost-effective. Eaton provides a solution to these requirements with the proven mini power center. It occupies considerably less space and can save up to 31 percent of the installation costs normally required when individual components are used. The solution is possible because a mini power center combines three individual components into one NEMAT Type 3R enclosure: a main breaker, an encapsulated single-phase or three-phase dry-type transformer, and a secondary distribution loadcenter with main breaker. Interconnecting wiring is completed at the factory. A mini power center is delivered ready for installation. It s also suitable for use as service entrance equipment. Ratings Single-phase: 3, 5, 7.5, 10, 15 and 25 kva Three-phase: 15, 22.5 and 30 kva A wide variety of proven applications Mini power centers are used wherever there is a 480V or 600V distribution system and loads requiring 208Y/120V, threephase or 120/240V, single-phase. Typical installations include: Industrial plant assembly lines Plant expansions Test equipment Temporary power at construction sites Sewage disposal plants Warehouses Car washes Parking lots Commercial buildings Irrigation systems Easy to install A variety of concentric knockouts on the sides and bottom Wiring compartment includes ample space for conduit entry Maximum wiring gutter space is provided for ease of wiring in compliance with NECT requirements Simplified design includes two keyholes for easy mounting and leveling 2 EATON CORPORATION Mini power centers

Mini power center components Circuit breakers Primary and secondary main breakers are Eaton s Type EHD or FDB (see catalog number information on pages 4 and 5) Aluminum chassis mini power centers are available with optional primary main circuit breakers having greater AIC ratings (see table below right) Feeder circuits can be easily added For aluminum chassis loadcenters, Eaton s Type BR plug-in feeder breakers (10 kaic) are used For copper chassis loadcenters, Eaton s Type BAB bolt-on feeder breakers (10 kaic) are used Feeder breakers are not included and are purchased separately Loadcenter Aluminum chassis standard for plug-in Type BR feeder breakers Copper chassis available for bolt-on Type BAB feeder breakers Space for up to 24 feeder breakers Ground bar is provided as standard for grounding of individual secondary circuits Neutral bar is grounded to the enclosure Transformer Electrical grade aluminum windings are standard with plug-in loadcenter chassis Electrical grade copper windings are standard with bolt-on loadcenter chassis; plug-in chassis are optional with copper windings 185ºC insulation system 115ºC winding temperature rise Sand and resin encapsulated core-coil assembly Cores are grounded with a copper lead Safety All live parts are enclosed for personnel safety and equipment protection Padlockable hinged front cover prevents removal of breakers Grounding terminal provided on the enclosure Provision to add padlock kit #PLK1 to lock primary main breaker ON/OFF Enclosures Standard NEMA 3R indoor/ outdoor heavy-gauge steel enclosure with a rugged baked-polymer polyester powder coat ANSI 61 gray color Optional NEMA 3R, grade 316 stainless steel Standards ULT listed and CSAT certified UL listed as service entrance equipment Meets applicable ANSI, NEMA, IEEET and UL standards Compare the space savings 30 inches instead of 72 inches! Specify the mini power center Compare the installation cost savings 31 percent less Because we knew that putting three components in one enclosure dramatically cuts installation time, we asked an electrical contractor to estimate the job two ways: Using a separate breaker, transformer and loadcenter, including the connecting cable and hardware Using a mini power center Here are the estimates: Installation 15 kva 25 kva Three- Component System Hours 1 Mini Power Center Three- Component System Switch and fuse layout 4 0 4 0 Switch and fuse mount 1 0 1 0 Transformer layout, remove knockout, etc. 16 16 24 24 Transformer fastened to wall 4 0 4 0 Loadcenter layout, mount and 4 4 6 4 connect source Total hours 29 20 39 28 % time saved with Eaton s mini power center 31% savings 28% savings 1 Time estimates are typical and will vary by geographical area. Optional primary main circuit breakers for plug-in chassis Primary Main Breaker 480V kaic 600V kaic EHD/FDB 14/14 /14 FD 25 18 HFD 65 25 FDC 100 35 Fused Switch Normal Layout 15 kva Three-Phase Transformer 72" Wide Mini Power Center P1 Transformer Loadcenter Loadcenter 30" Wide P2 Mini Power Center P1 Primary Breaker P2 Secondary Breaker EATON CORPORATION Mini power centers 3

Product selection Mini power centers, and other dry-type transformers, are stocked by Eaton distributors. They are supported by regional distribution centers that maintain extensive inventories of virtually every dry-type transformer. For the distributor nearest you, call toll free 1-800-525-2000. Catalog number information Plug-In Mini Power Center (Aluminum-Wound Transformer and Loadcenter Chassis Standard) kva Style Number Full Capacity Taps FCBN Dimensions in Inches (mm) 1 Weight Main Circuit Breaker 2 Height Width Depth Lbs (kg) Frame Primary 3 Secondary Feeder Breakers Max. Number 45 Single-Phase 480V to 120/240V 3 P48G11S03P 2 at 5% 27.50 (698.5) 11.90 (302.3) 8.90 (226.1) 105 (47) 283 EHD2015 BR215 8 4 12 5 P48G11S05P 2 at 5% 29.50 (749.3) 11.90 (302.3) 8.90 (226.1) 105 (47) 284 EHD2020 BR225 12 6 20 7.5 P48G11S07P 2 at 5% 29.50 (749.3) 11.90 (302.3) 8.90 (226.1) 125 (56) 284 EHD2030 BR230 12 6 30 10 P48G11S10P 2 at 5% 32.50 (825.5) 13.10 (332.7) 11.60 (294.6) 177 (80) 285 EHD2040 BR250 12 6 40 15 P48G11S15P 2 at 5% 37.50 (952.5) 13.10 (332.7) 11.60 (294.6) 212 (96) 286 EHD2060 BR270 20 10 60 25 P48G11S25P 2 at 5% 43.40 (1102.4) 15.90 (403.9) 14.50 (368.3) 373 (169) 287 EHD2100 BR2125 26 13 100 600V to 120/240V 5 P60G11S05P 2 at 5% 29.50 (749.5) 11.90 (302.3) 8.90 (226.1) 105 (47) 284 FDB2015 BR225 12 6 20 7.5 P60G11S07P 2 at 5% 29.50 (749.5) 11.90 (302.3) 8.90 (226.1) 125 (56) 284 FDB2030 BR230 12 6 30 10 P60G11S10P 2 at 5% 32.50 (825.5) 13.10 (332.7) 11.60 (294.6) 177 (80) 285 FDB2040 BR250 12 6 40 15 P60G11S15P 2 at 5% 37.50 (952.5) 13.10 (332.7) 11.60 (294.6) 212 (96) 286 FDB2060 BR270 20 10 60 25 P60G11S25P 2 at 5% 43.40 (1102.4) 15.90 (403.9) 14.50 (368.3) 373 (169) 287 FDB2100 BR2125 26 13 100 Three-Phase 480V to 208Y/120V 15 P48G28T15P 2 at 5% 36.10 (916.9) 28.80 (731.5) 9.40 (238.8) 320 (145) 289 EHD3040 EHD3050 18 9 40 22.5 P48G28T21P 2 at 5% 40.90 (1038.9) 29.90 (759.5) 13.60 (345.4) 565 (256) 290 EHD3070 EHD3070 18 9 60 30 P48G28T30P 2 at 5% 41.90 (1064.3) 29.90 (759.5) 13.60 (345.4) 635 (288) 291 EHD3090 EHD3100 24 12 80 600V to 208Y/120V 15 P60G28T15P 2 at 5% 36.10 (916.9) 28.80 (731.5) 9.40 (238.8) 320 (145) 289 FDB3030 EHD3050 18 9 40 22.5 P60G28T21P 2 at 5% 40.90 (1038.9) 29.90 (759.5) 13.60 (345.4) 565 (256) 290 FDB3050 EHD3070 18 9 60 30 P60G28T30P 2 at 5% 41.90 (1064.3) 29.90 (759.5) 13.60 (345.4) 635 (288) 291 FDB3070 EHD3100 24 12 80 1 Not for construction purposes. 2 Secondary main breakers fixed only. No substitutes for ampere rating. 3 Optional AIC rated main breakers available. See table on page 3. 4 Combinations can be selected. 5 Feeder breakers not included. Use Eaton s Type BR family. Single- Two- Max. Amp 4 EATON CORPORATION Mini power centers

Catalog number information Bolt-On Mini Power Center (Copper-Wound Transformer and Loadcenter Chassis Standard) kva Style Number Full Capacity Taps FCBN Dimensions in Inches (mm) 1 Weight Main Circuit Breaker 2 Height Width Depth Lbs (kg) Frame Primary 3 Secondary Single- Feeder Breakers Max. Number 45 Single-Phase 480V to 120/240V 3 P48G11S03CUB 2 at 5% 33.25 (844.6) 12.56 (319.0) 9.66 (245.4) 105 (47) 306 EHD2015 BAB2015 12 6 12 5 P48G11S05CUB 2 at 5% 36.14 (918.0) 12.56 (319.0) 9.66 (245.4) 110 (50) 307 EHD2020 BAB2025 18 9 20 7.5 P48G11S07CUB 2 at 5% 36.14 (918.0) 12.56 (319.0) 9.66 (245.4) 110 (50) 307 EHD2030 BAB2030 18 9 30 10 P48G11S10CUB 2 at 5% 40.85 (1037.6) 13.47 (342.1) 11.82 (300.2) 180 (82) 308 EHD2040 BAB2050 18 9 40 15 P48G11S15CUB 2 at 5% 43.91 (1115.3) 14.97 (380.2) 11.82 (300.2) 215 (98) 309 EHD2060 BAB2070 24 12 60 25 P48G11S25CUB 2 at 5% 43.37 (1101.6) 20.41 (518.4) 14.58 (370.3) 385 (175) 310 EHD2100 5 BAB212 30 15 100 600V to 120/240V 3 P60G11S03CUB 2 at 5% 33.25 (844.6) 12.56 (319.0) 9.66 (245.4) 105 (47) 306 FDB2015 BAB2015 12 6 12 5 P60G11S05CUB 2 at 5% 36.14 (918.0) 12.56 (319.0) 9.66 (245.4) 110 (50) 307 FDB2020 BAB2025 18 9 20 7.5 P60G11S07CUB 2 at 5% 36.14 (918.0) 12.56 (319.0) 9.66 (245.4) 110 (50) 307 FDB2030 BAB2030 18 9 30 10 P60G11S10CUB 2 at 5% 40.85 (1037.6) 13.47 (342.1) 11.82 (300.2) 180 (82) 308 FDB2040 BAB2050 18 9 60 15 P60G11S15CUB 2 at 5% 43.91 (1115.3) 14.97 (380.2) 11.82 (300.2) 215 (98) 309 FDB2060 BAB2070 24 12 60 25 P60G11S25CUB 2 at 5% 43.37 (1101.6) 20.41 (518.4) 14.58 (370.3) 373 (169) 310 FDB2100 BAB2125 30 15 100 Three-Phase 480V to 208Y/120V 15 P48G28T15CUB 2 at 5% 36.12 (917.4) 28.75 (730.3) 9.38 (238.3) 320 (145) 289A EHD3040 BAB3050H 18 9 6 40 22.5 P48G28T21CUB 2 at 5% 40.88 (1038.4) 29.88 (759.0) 13.63 (346.2) 565 (257) 290A EHD3070 BAB3070H 18 9 6 60 30 P48G28T30CUB 2 at 5% 41.88 (1063.8) 29.88 (759.0) 13.63 (346.2) 635 (288) 291A EHD3090 BAB3100H 24 12 8 80 600V to 208Y/120V 15 P60G28T15CUB 2 at 5% 36.12 (917.4) 28.75 (730.3) 9.38 (238.3) 320 (145) 289A FDB3030 BAB3050H 18 9 6 40 22.5 P60G28T21CUB 2 at 5% 40.88 (1038.4) 29.88 (759.0) 13.63 (346.2) 565 (257) 290A FDB3050 BAB3070H 18 9 6 60 30 P60G28T30CUB 2 at 5% 41.88 (1063.8) 29.88 (759.0) 13.63 (346.2) 635 (288) 291A FDB3070 BAB3100H 24 12 8 80 1 Not for construction purposes. 2 Main breakers fixed only. No substitutes for ampere rating. 3 Optional AIC rated main breakers available. See table on page 3. 4 Combinations can be selected. 5 Feeder breakers not included. Use Eaton s Type BAB family. Two- Three- Max. Amp EATON CORPORATION Mini power centers 5

Eaton is dedicated to ensuring that reliable, efficient and safe power is available when it s needed most. With unparalleled knowledge of electrical power management across industries, experts at Eaton deliver customized, integrated solutions to solve our customers most critical challenges. Our focus is on delivering the right solution for the application. But, decision makers demand more than just innovative products. They turn to Eaton for an unwavering commitment to personal support that makes customer success a top priority. For more information, visit www.eaton.com/electrical. Eaton Corporation Electrical Sector 1111 Superior Ave. Cleveland, OH 44114 United States 877-ETN-CARE (877-386-2273) Eaton.com 2011 Eaton Corporation All Rights Reserved Printed in USA Publication No. BR00904003E / Z11729 November 2011 Eaton is a registered trademark of Eaton Corporation. All other trademarks are property of their respective owners.