ZC-24DO CANopen I/O Module: 24 Digital Outputs



Similar documents
Product EASY-USB. Description. USB - UART TTL converter. Seneca s.r.l. support@seneca.it sales@seneca.it. Series of product. Pag.

4 non-safe digital I/O channels 2 IO-Link Master V1.1 slots. Figure 1. Figure 2. Type code. TBPN-L1-FDIO1-2IOL Ident no

Rack mounted telephone- and leased line modem for industrial applications

DVPPF02-H2. PROFIBUS DP Slave Communication Module Application Manual

Programmable set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2

TEMON 8-C. Doc. N MO-0370-ING TEMPERATURE MONITOR DEVICE TYPE TEMON 8-C OPERATION MANUAL. Microener - Copyright 2010 FW 2.2 Date Rev.

Z-TWS4. Multifunction Straton / LINUX Controller.

CPB. Doc. N MO-0279-ING MODBUS/PROFIBUS DP CONVERTER TYPE CPB. Microener - Copyright 2010 Date Rev. 0

Telephone- and leased line modem for industrial applications TD-36

RPDO 1 TPDO 1 TPDO 5 TPDO 6 TPDO 7 TPDO 8

Application/Connection Examples

Set for PROFINET IO in IP20 TI-BL20-EN-PN-4

PCS0100en Persy Control Services B.V. Netherlands

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC A - M8 connector

Digital input modules

ENET-710. ENET Ethernet Module ENET-710 JAN / 06 FOUNDATION

1 Serial RS232 to Ethernet Adapter Installation Guide

TX OPEN RS232/485 module

is then retained absolutely without interruption.

FOSTCDR. Industrial Serial to Multimode Fiber Optic Converter PRODUCT INFORMATION B&B ELECTRONICS. Specifications Serial Technology

User Manual Revision English

WEA-Base. User manual for load cell transmitters. UK WEA-Base User manual for load cell transmitters Version 3.2 UK

Electronic Control Devices The European Product Catalogue 2007

DAM Series DAM124 4DIN+8AI+4DO Module Model No.:DAM124 WebSite:

Programmable set for Ethernet Modbus/TCP in IP20 TI-BL20-PG-EN-8

Zlinx Wireless I/O. Peer-to-Peer and Modbus I/O B&B ELECTRONICS PRODUCT INFORMATION

AXIS T81B22 DC 30W Midspan

MANUAL PC1000R

INSTALLATION GUIDE. Card Reader & Controller with KIM Swipe Reader for Solitaire 850 / 950 / 850L Learnlok PK2930

User Manual Revision English

Compact multiprotocol I/O module for Ethernet 8 digital PNP inputs and 8 digital PNP outputs 2 A TBEN-L1-8DIP-8DOP

HCS-3300/3302/3304 USB Remote Programmable Laboratory Grade Switching Mode Power Supply

User Manual Revision English

L5354 ControlNet Communications Interface

CQM1-SF200/CS1W-SF200

Hardware Manual RM CANview Ethernet

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

User Manual Revision English

CMC-DN01 DeviceNet Slave Communication Card Operation Manual

2-Port RS232/422/485 Combo Serial to USB2.0 Adapter (w/ Metal Case and Screw Lock Mechanism) Installation Guide

Model SPDT Relays

User Manual Revision English

R60 USB to CAN interface Manual (1.5 EN)

Provides one channel for Ethernet over existing

Versions. Q.station Q.station T. Q.station D. Q.station DT x x

User Manual Revision English

User Manual V SDM220MODBUS. Single-Phase Two Module DIN rail Meters

HCR3.2/.. Chipcard reader HOTEL SOLUTION

Installation Manual (English) Adjustable Active DP Terminator T1-Pepper Active RS485 segment termination for non-compliant cable

MDM192 MULTI-DROPS DIGITAL MODEM FOR PRIVATE LINE. USER GUIDE Document reference :

Electronic Control Devices The European Product Catalogue 2007

PSU-U-24V/AC-6A/10/FTA-TR-MC PSAC 0624

Fieldbus slave modules with I/Os, DIO

PD 100A. Printing data system

16-Port RS232 to USB2.0 High Speed Multi Serial Adapter (w/ Metal Case) Installation Guide

User Manual Revision English

Application. Characteristics RTU560. Data Sheet Communication Unit 560CMD11. Communication Unit 560CMD11

DALI RC BASIC SO. Control unit Operating instructions

LevelOne IFE Port PoE + 1-Port TP Industrial Fast Ethernet Switch User Manual

User Manual Revision English

User Manual Revision English

TrueAlarm Fire Alarm Systems

MAKING MODERN LIVING POSSIBLE. AK-SC255 On-Site Installation Guide DANFOSS ELECTRONIC CONTROLS & SENSORS

CMC-PD01 PROFIBUS DP Slave Communication Card Operation Manual

ABB Drives. User s Manual. Pulse Encoder Interface Module RTAC-01

Duct Humidity Transmitter

MCR1900 Media Converter 19-Slot Chassis

Vroom Hardware manual ver Code 114VROOHWE00. Vroom CANBUS USER INTERFACE WITH LCD GRAPHIC DISPLAY AND WITH TEMPERATURE AND HUMIDITY SENSOR

Set for Profibus DPV1 in IP20 TI-BL20-DPV1-8

User Manual Revision English

=============================== WARNING

LDG DTS-4/4R Desktop Coaxial Switch / Remote

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

User manual Compact Web PLC WP240 series IEC-line

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

IntesisBox KNX Modbus RTU master

USER MANUAL V5.0 ST100

OVR Three-Phase Recloser and PCD Control Style Guide 1VAL SG October 13, 2009 Revision F

TP32MTT.03 TP32MTT [ GB ] Probes for soil thermal profile measurement

Solar Home System. User Manual. AEH-SHS01-10W2L Solar Home System 2 Lamps

IPS Magneto-Thermal protection device for electric loads.

Install the DeviceNet Module using the following procedure:

ELECTRONIC CONTROL UNITS. Machine Management Systems. Description. EC-MMS-1012-H 10 inputs, 12 outputs meter-in systems controller 20

Modular I/O System Analog and Digital Interface Modules

alpha DSL WTM HS Instructions for use ADSL modem alpha DSL WTM HS

LS1024B / LS2024B/ LS3024B. Solar Charge Controller USER MANUAL

Product and functional description

User Manual Revision English

GSR 12/24V. GSR 12/24V Technical manual Model 12/24

GTR-128/GTR-129 Motorcycle/ Vehicle Tracker Quick Start Guide

ALARM ANNUNCIATOR ME INSTRUCTION MANUAL

Quick Connect. quick - simple - efficient.

R.C.C.B. s two-pole LEXIC

Provides one channel for Ethernet over existing

10000HXL31/15000HXL31/20000HXL31

Operating Manual UMB Analogue/Digital Converter ANACON Order Number: 8160.UANA

User Manual Revision English

DeviceNet Communication Manual

Transcription:

Z-PC Line EN ZC-24DO CANopen I/O Module: 24 Digital Outputs Installation Manual Contents: - General Specifications - Technical Specifications - Installation Rules - Electrical connections - DIP-switches settings - Programming - Significant Components Position - Leds Signallings - Accessories SENECA s.r.l. Via Germania, 34-35127 - Z.I. CAMIN - PADOVA - ITALY Tel. +39.049.8705355-8705359 - Fax +39.049.8706287 For manuals, EDS files and configuration software, see www.seneca.it This document is property of SENECA srl. Duplication and reprodution are forbidden, if not authorized. Contents of the present documentation refers to products and technologies described in it. All technical data contained in the document may be modified without prior notice Content of this documentation is subject to periodical revision. MI001520-I/E ENGLISH - 1/8

General Specifications 24 Mosfet Digital Outputs with shared negative pole, 5-30 VDC collectively supplied. Digital outputs available both by terminals and IDC10/ IDC20 connectors to facilitate the connection to external relays. Can Interface with CANopen protocol: up to 1 Mbps speed. CANopen Baud rate and Node ID configurability by DIP-switches or software. RS232 Serial Communication with MODBUS-RTU protocol. Facilitated power supply and CANopen bus wiring by means of the bus housed in the DIN rail. 1500 VAC Isolation among input, power supply and CAN interface circuits. Overtemperature and short-circuit to ground of digital outputs continuous monitoring and consequent fault condition signalling. Outputs value in case of no communication or fault condition: programmable value or last set value. Leds Signallings: Power Supply, Digital Outputs State, CAN Communication, MODBUS-RTU Communication, Outputs fault. Technical Specifications OUTPUTS Numbers of Channels 24 Outputs Type Power Supply Voltage Maximum current (for each output) RDS on ON/OFF delay Voltage Consumption Temperature MOSFET (Open Source) 5-30VDC 0.5 A (connection from terminals) 25 ma (connection from connectors) 0.75 Ω Max1ms POWER SUPPLY 10-40VDC 19-28VAC Typical: 1.5 W, Max: 2.5 W ENVIRONMENTAL CONDITIONS -10 - +65 C MI001520-I/E ENGLISH - 2/8

Humidity Altitude Storage Temperature Protection Removable Terminals Rear IDC10 Connector IDC10 / IDC20 Connectors Stereophonic frontal jack Dimensions Box Isolation Diagram: 3-Point 1500 VAC Isolation 30-90% at 40 C non condensing. up to 2000 m a.s.l -20 - +85 C IP20 CONNECTIONS 4-way screw terminals (3.5 mm pitch): outputs. CAN Interface and power supply (for DIN rail). Outputs (on the rear, alternatively to terminals). 3.5 mm; RS232 (COM). DIMENSIONS / BOX L: 100 mm, H: 112 mm, W: 35 mm PBT, black ISOLATIONS / STANDARDS Standards The module complies with the following standards: EN61000-6-4/2002-10 (electromagnetic emission, industrial environment). EN61000-6-2/2006-10 (electromagnetic immunity, industrial environment). EN61010-1/2001 (safety). All circuits must be isolated from the other circuits under dangerous voltage with double isolation. The power supply transformer must comply with EN60742: Isolated transformers and safety transformers. Installation Rules The module is designed to be installed in vertical position on a DIN 46277 rail. In order to ensure optimum performance and the longest working life, the module(s) must be supplied adequate ventilation and no raceways or other objects that obstruct the ventilation slots. Never install modules above sources of heat; we recommend installation in the lower part of the control panel. Inserting on the DIN rail As it is illustrated in the next figure: 1) Insert the rear IDC10 connector on a DIN rail free slot (the inserting is univocal since the connectors are polarized). 2) Tighten the two locks placed at the sides of the rear IDC10 connector to fix the module. MI001520-I/E ENGLISH - 3/8

Electrical Connections POWER SUPPLY AND CAN INTERFACE Power Supply and CAN interface are available by using the bus for the Seneca DIN rail, by the rear IDC10 connector or by Z-PC-DINAL-B accessory (see Accessories). Rear Connector (IDC10) In the figure the meaning of the IDC10 connector pins is showed, in the case the user decides to provide the signals directly through it. Z-PC-DINAL-B Accessory Use In case of Z-PC-DINAL-B accessory use, the signals may be provided by terminal blocks. The figure shows the meaning of the terminals and the position of the DIP-switch (present on each DIN rail supports listed on Accessories) for CAN network termination. GNDSHLD: Shield to protect the connection cables (always CAN bus Connection Rules 1) Install the modules on the DIN rail (max 120). 2) Connect the remote modules using cables of proper length. On the table the following data about the cables length are provided: -Bus Length: CAN network maximum length as a function of the Baud rate. It is the lenght of the cables which connect the two bus terminators modules (see Scheme 1). -Drop Length: maximum length of a drop line (see Scheme 1) as a function of the Baud Rate. Baud rate Bus Drop Length Length 20 kbps 2500 m 150 m 50 kbps 1000 m 60 m 125 kbps 500 m 5m 250 kbps 250 m 5m 500 kbps 100 m 5m 800 kbps 50 m 3m 1000 kbps 25 m 0.3 m Scheme 1 For the best performances, the use of special shielded cables is recommended (BELDEN 9841 cable for example). 3) Terminate the two ends of the CANbus network by setting to ON the DIP-switch present on the DIN rail connection supports (see Accessories) where the two ends are inserted. MI001520-I/E ENGLISH - 4/8

DIGITAL OUTPUTS Digital Outputs Connections from terminals The total current entering on power supply terminal must be limited to 12 A with quick-break fuse or equivalent protection. Max Vext: 30 VDC, Max Current (for each output): 0.5 A Digital Outputs Connections from connectors (module rear side) Connection suggested to supply 24 V relays. The total current entering on power supply terminal must be limited to 0.6 A with quick-break fuse or equivalent protection. Max. current for each output: 25 ma. IDC10: DOUT 17..DOUT 24 IDC20: DOUT 1..DOUT 16 MI001520-I/E ENGLISH - 5/8

RS232 SERIAL PORT The connection cable DB9 with a 3.5 mm stereophonic jack, can be assembled as indicated in the following figure, or can be bought as an accessory (see Accessories). DIP-switches Settings The DIP-switches position defines the module CAN communication parameters: Address and Baud Rate. In the following figure the Baud Rate and Address values are listed as a function of the DIP-switches position: We underline that on all the DIN rail supports listed on Accessories a DIP-switch is present and if it is set to ON position the CAN network termination is inserted. Programming PROGRAMMING THROUGH CAN INTERFACE The module may be programmed/configured through the CAN interface; refer to the User Manual for details about the communication. Factory CAN Parameters With all the DIP-switches in OFF position (values from memory), the module is originally programmed as follows: Baud Rate: 20 kbps, Address: 1 PROGRAMMING THROUGH RS232 The module may be programmed/configured through the RS232 interface by using MODBUS-RTU protocol; refer to the User Manual for details about the communication. The connection parameters are the following: Address: 1, Baud Rate: 2400 Baud, Parity: none, Stop bit: 1. MI001520-I/E ENGLISH - 6/8

Significant Components Position TERMINALS/LEDS/CONNECTORS/DIP-SWITCHES The terminals numbering, the leds position on the frontal panel, the IDC10 / IDC20 connectors and the DIP-switch on the rear side are illustrated below. Frontal Panel Rear Side Leds Signallings LEDS ERR AND RUN: CANOPEN COMMUNICATION STATE The meaning of leds ERR and RUN is described below; refer to the User Manual for details about the possible state and the flashing modes of the two leds. Led ERR (Red) Meaning N LED ERR (Red) STATE DESCRIPTION 1 Off No error The Device is in working condition. 2 Single flash Warning limit reached At least one of the error counters of the CAN controller has reached or exceeded the warning level (too many error frames). Error Control 4 Double flash Event A guard event (NMT-Slave or NMT-master). 5 Triple flash Sync Error The SYNC message has not been received within the configured communication cycle period time out. 6 On Bus off The CAN controller is bus off. MI001520-I/E ENGLISH - 7/8

Led RUN (Green) Meaning N LED RUN (Green) STATE DESCRIPTION 2 Single flash Stopped The Device is in STOPPED state. 3 Blinking Pre-Operational The Device is in the PRE-OPERATIONAL state. 4 On Operational The Device is in the OPERATIONAL state. LEDS FAIL AND PWR: GENERAL SYSTEM DIAGNOSTICS LED PWR (Green) Meaning LED FAIL (Yellow) Meaning On Power Supply presence. On/Blinking -Data reception on the RS232 port (COM). -Fault: at least an output is in fault condition. LEDS 01..24: DIGITAL OUTPUTS STATE LEDS 01..24 (Green) On Meaning The corresponding output (01..24) is ON. Accessories SUPPORTS FOR MOUNTING ON DIN RAIL GUIDE/ SERIAL CABLE Code Z-PC-DINAL-A Z-PC-DINAL-B Z-PC-DIN2-A Z-PC-DIN2-B Z-PC-DIN8-A Z-PC-DIN8-B PM001600 Description Bus Support: Terminal blocks + 2 slots to connect Z-PC line modules. Bus Support: Terminal blocks + 1 slot to connect Z-PC line modules. Bus Support: 2 slots to connect Z-PC line modules. Bus Support: 1 slot to connect Z-PC line modules. Bus Support: 8 slots to connect Z-PC line modules. Bus Support: 4 slots to connect Z-PC line modules. Serial Cable: from 3,5 mm stereo Jack to DB9F. Disposal of Electrical & Electronic Equipment (Applicable throughout the European Union and other European countries with separate collection programs). This symbol, found on your product or on its packaging, indicates that this product should not be treated as household waste when you wish to dispose of it. Instead, it should be handed over to an applicable collection point for the recycling of electrical and electronic equipment. By ensuring this product is disposed of correctly, you will help prevent potential negative consequences to the environment and human health, which could otherwise be caused by inappropriate disposal of this product. The recycling of materials will help to conserve natural resources. For more detailed information about the recycling of this product, please contact your local city office, waste disposal service or thè retail store where you purchased this product. MI001520-I/E ENGLISH - 8/8