LON-bus LON-bus accessies Remote display, indication and control f Synova FC700A and FC330A control panels Synova Proven LON-bus technology, fault-free and reliable Compact 2 x 40 character LCD flo repeaters, displaying messages including service, isolation and alarm events LED indication unit f alarm and fault status LED driver module f easy assembly and customized mimic panel Relay outputs and input / output modules All accessies are designed to blend into existing building designs Easy system expansion and customisation Low maintenance Flush surface mounting
Features The LON-bus interface provides drive capability f flo repeater panels, parallel indicats and mimic panels. This enables system status to be viewed anywhere within a building. The LON-bus interface also enables remote operation of the fire control devices. Product features and capabilities The is a stand-alone infmation bus. It provides functions, which f security reasons, are not on the detect bus. Infmation displays, f example, flo repeater panels, etc. can be positioned up to 1000 metres from the control panel using easily managed, unshielded cabling. The easily installed LON-bus interface mounts within the control panel and suppts the direct connection of flo repeater panels which make small autonomous control panels. Up to 32 devices can be connected to FC700A control panel. A maximum of 16 devices is possible with FC330A control panel. Application The LON-bus is ideal f use in large buildings. It enables system status infmation to be viewed and controlled independent of the location of the main control panel by the addition of flo repeater panels, parallel indicats and mimic panels. Specific installation plant requirements can be easily met with the LON-bus. F example, warning devices (emergency exit signs etc.) can be operated via additional relay cards that may be individually controlled in the event of an emergency. Installation Standard twisted (min. 10 turns per metre) and unshielded cable. Max. length: up to 1000 m if used as stub line, up to 500 m if used as free topology. Free polarity. System overview 24 VDC power supply interface Control in/output modules LON/Synoptic converter Databus Flo repeater panels Parallel indicats Synoptic / relay 2
System overview (continued) Operating terminal FT700A Fire detection system [1] FC700A Fire detection system [3] FC330A Fire detection system [4] FC330A-ECO1 C-Bus [2] I-Bus / interface E3I040 [5] RS232 / interface K3I080 Monited bus, up to 1000 m Flo repeater panels [8] B3Q595 [7] B3Q590 [6] B3Q580 [9] Input / Output card K3I110 [10] LON / mimic converter K3I050 [11] LED indicat panel B3R051 2 x 24 red and yellow LEDs [10] LON / mimic converter K3I050 up to 1000 m [13] Relay card K3G060 [12] Output driver card K3R072 [13] Relay card K3G060 [10] LON / mimic converter K3I050 [12] Output driver card K3R072 [15] LED ribbon cable F50F410 [14] Mimic panel 3
System overview (continued) [1] FC700A Addressable netwkable fire control panel Up to 16 FC700A fire control panels can be connected via C-Bus netwk. Each FC700A control panel accommodates up to 1000 devices. devices are connected to FC700A via I- Bus / interface. [2] I-Bus / interface E3I040 f FC700A control panel and FT700A operating terminal Converter between I-Bus and. Up to 32 devices connectable. Monited two-wire bus without loop line function. Mounting accessy Z1B070 To secure the LON interface E3I040 in H28G200 (FT700A) housing. Note: Incpation of LON interface E3I040 in the FT700A operating terminal prohibits the addition of B3R051 parallel indicat panel on the H28T110 do. [3] FC330A Two-loop addressable fire control panel Expandable to four loops. Accommodates up to 512 addressable devices. devices are connected to FC330A via RS232 / interface. [4] FC330A-ECO1 One-loop addressable fire control panel Accommodates up to 128 addressable devices. is connected to FC330A-ECO1 via RS232 / interface. [5] RS232 / interface K3I080 f FC330A and FC330A-ECO1 control panels K3I080 can be fitted within the panel at any time f expansion retrofit purposes. Up to 16 devices connectable. Monited two-wire bus without loop line function. [6] + [7] + [8] Flo repeater panels Flo repeater panels display system messages in areas remote from the panel. F example, in another flo, wing building. All alarm messages can be indicated on all flo repeater panels and the control panel. Flo repeater panels are constantly monited. If the LON-bus cabling is cut, a fault message is shown on the affected flo repeater panel and the control panel. Flo repeater panels do not require configuration. All that is required is f an address to be locally set. 32 (FC700A) 16 (FC330A) flo repeater panels can be directly connected to the LON-bus. Different types of repeater panels with without control functions are available to suite customer needs. [6] Flo repeater panel B3Q580 The flo repeater panel (B3Q580) is designed f the remote indication of system messages. Panels can selectively display messages; alarms, warnings and faults. A user-friendly scroll key enables viewing of up to 200 messages. A built-in buzzer provides additional audible notification of alarm messages. [7] Flo repeater panel with control functions B3Q590 The flo repeater panel (B3Q590) is used both f the remote indication of messages and to provide acknowledge and reset control functions in the event of an alarm. B3Q590 is ideally suited as a mini control centre at entrances. It enables the control panel to be reset to nmal operation after an event, simply by pressing a button. Operation of the B3Q590 is enabled by means of a key switch. [8] Flo repeater panel with control functions B3Q595 The B3Q595 is a further development of the B3Q590 with the same features and advantages. Additionally, B3Q595 can be included within a like-keyed security concept. [9] Input / Output card K3I110 The K3I110 offers 16 inputs and 16 outputs (relay potential free 30V/1A) at the same time. The inputs can be supervised alternatively on open line open line and sht circuit. On the LON-bus up to 32 (FC700A) 16 (FC330A) input / output-cards can be connected. [10] LON / mimic converter K3I050 On the LON-bus up to 32 (FC700A) 16 (FC330A) LON / mimic converters (K3I050) can be connected. Each can drive up to 24 LED indicating panels (B3R051) 24 output driver cards (K3R072). 8 individual addresses f B3R051 / K3R072 on the local data bus are possible with FC700A control panel, two individual addresses are possible with FC330A / FC330A-ECO1 control panel. K3I050 has buzzer, lamp test and other inputs / outputs. [11] LED indicating panel B3R051 Events associated with fire zones areas are displayed in the simplest manner using the B3R051 LED indicating panels. Two multiplied 24 coloured LEDs show the state of the system at any time. Red indicates an alarm and yellow indicates that the relevant zone is switched off (e.g. due to building maintenance wk, etc.). B3R051 panels are connected to the LON-bus by means of K3I050 converters. Up to 24 LED indicating panels (B3R051) displaying identical infmation may be connected to a single K3I050 converter. 4
System overview (continued) [12] Output driver card K3R072 A single K3R072 driver output card suppts 2 devices; either 2 relay cards (K3G060); 2 LED flat cables (F50F410), one of each, f a total of 48 individually addressable outputs. K3R072 has buzzer, lamp test and other inputs / outputs [13] Relay card K3G060 Customer requirements can be exactly met by means of K3G060 relay cards. 24 individually addressable relays provide outputs f installation controls such as control of emergency exit signs, voice alarms, announcements, etc. [14] Mimic panel Mimic panels can be easily designed around a site layout flo plan using K3R072 output driver cards and F50F410 LED flat cables. The required flo plan situation plan fms the front of the mimic panel. The individually addressable LEDs of the flat cable are the infmation carriers on the front panel in the same manner as LED indicating panel B3R051. The LED flat cables connect directly to the K3R072 output driver cards. The complete mimic panel connects to the LON-bus via the K3I050 LON/mimic converter card. [15] LED ribbon cable, 1m, with 24 red LED's F50F410 Two F50F410 LED cables can be connected directly to the driver output card (K3R072) to offer a total of 48 (2 x 24) red LED. The LED can be easily configured via the Synova configuration tool SWE330A. Cable length 1 m. Technical data Type B3Q580 B3Q590/9 B3R051 K3I050 K3R072 K3G060 K3I110 5 Power supply 9-45VDC 9-45VDC 9-45VDC 9-45VDC 9-45VDC 9-45VDC 9-45VDC Power consumption 24V quiescent 24V max. Nominal power Output buzzer Output LED ON Relays 20mA 100mA 18mA 120mA 40mA 140mA 15mA 30mA 50mA/ 22VDC 3,3VDC/ 10mA 40mA 140mA 12mA/ 24VDC 6mA 90mA 24mA 184mA Contact rating 30VDC/1A 30VDC/1A Dimensions (in mm) Width Height Depth (with housing) Reference documents 219 66 (76) 219 66 (76) 219 55 (76) 105 200 45 105 200 45 105 200 45 220 45(76) Doc. no.1583 Synova FC330A Planning, Installation, Commissioning, Operating Programming, Trouble Shooting, Maintenance Doc. no. 1923 Synova FC330A Remote indicating & Control devices, Logging Printer (Installation & Commissioning). Doc. no. 007836 Synova FC700A Planning Doc. no. 007831 Synova FC700A Hardware description Modules 5
Accessies B3Q580 / B3Q590 / B3Q595 B3R051 K3I050 K3G060 Surface mounting Surface mounting Z3I530 Flush mounting F12A100 F12A470 76 K3R072 K3I110 Wall cutout H23U230 H23Z230 Flush mounting 160 78 H23U220 H23Z230 Wall cutout F50F410 Z3I520 (optional) K3I110 Details f dering Type Part no Designation Weight E3I040 499310 RS232 / LON-bus converter 0.325kg Z1K030 484231 Terminal block with p.c.b. chassis f mounting E3I040 in FC700A housing 0.051kg Z1B070 A5Q00001720 Mounting accessy f E3I040 in housing H28G200 0.170kg K3I080 504768 RS232 / LON-bus converter 0.178kg K3I110 528812 Input/output card with 16 in- and outputs 0.597kg Z3I1000 559344 Additional power supply 0.880kg B3Q580 496177 Flo repeater panel 0.619kg B3Q590 496180 Flo repeater panel with control functions, Ndic access key 0.675kg B3Q595 534110 Flo repeater panel with control functions, Like-Keyed concept 0.735kg Z5B710 510448 Inscription stripes set Ndic to B3Q580 (SE, NO, FI, DK) - Z5B720 510451 Inscription stripes set Europe to B3Q580 (GB, DE, FR, IT) - Z5B730 510464 Inscription stripes set Ndic to B3Q59x (SE, NO, FI, DK) - Z5B740 510477 Inscription stripes set Europe to B3Q59x (GB, DE, FR, IT) - 475091 Housing to B3Q580 / B3Q590 / B3Q595 / B3R051 / K3I110 0.197kg H23U230 532879 Recess box to B3Q580 / B3Q590 / B3Q595 0.462kg H23Z230 532882 Flush mount frame to B3Q580 / B3Q590 / B3Q595 / B3R051 0.204kg H23U220 379126 Recess box to B3R051 0.462kg K3I050 496766 LON/mimic converter 0.237kg Z3I520 484969 Cable set, 12 cables with connect 0.5m 0.055kg Z3I530 484972 Adapter f K3I050 to external B3R051 / K3R072 0.058kg F12A100 495275 Flat cable micro 12 pin, 0.4m 0.008kg F12A470 495288 Flat cable micro 12 pin, 1.5m 0.021kg K3R072 528605 Driver output card 0.273kg F50F410 529141 LED flat cable, 1m, with 24 red LED s 0.108kg K3G060 528786 Relay card, 24 NO contacts, rating 1A/30V 0.396kg B3R051 490513 LED indicating panel 2x24 LED s 0.448kg AG Alte Landstr. 411 CH-8708 Männedf Tel. +41 1-922 6111 Fax +41 1-922 6450 www.sbt.siemens.com 2004 Copyright by AG Data and design subject to change without notice. Supply subject to availability. Document no. 007349_b_en_-- Manual FD-C Edition 12.2003 Section 8