Gas Chromatographic Analyses

Similar documents
Fractional Distillation and Gas Chromatography

Chemistry 321, Experiment 8: Quantitation of caffeine from a beverage using gas chromatography

Gas Chromatography. Let s begin with an example problem: SPME head space analysis of pesticides in tea and follow-up analysis by high speed GC.

1.1 This test method covers the qualitative and quantitative determination of the content of benzene and toluene in hydrocarbon wax.

Separation of Amino Acids by Paper Chromatography

Lecture Chromo-3: Gas Chromatography. CHEM 5181 Fall 2004 Mass Spectrometry & Chromatography. Jessica Gilman and Prof. Jose-Luis Jimenez CU-Boulder

Pesticide Analysis by Mass Spectrometry

Paper Chromatography: Separation and Identification of Five Metal Cations

Identification of Arson Accelerants by Gas Chromatography

Theory and Instrumentation of GC Introduction

Ferda ORHUN Mineral Research and Exploration Institute of Turkey

Background Information

Name Lab #3: Solubility of Organic Compounds Objectives: Introduction: soluble insoluble partially soluble miscible immiscible

For Chromatography, you must remember Polar Dissolves More, not like dissolves like.

ANALYSIS OF ASPIRIN INFRARED (IR) SPECTROSCOPY AND MELTING POINT DETERMINATION

GAS CHROMATOGRAPHY. DETERMINING THE PERCENT COMPOSITION OF A MIXTURE OF VOLATILE LIQUIDS USING A GAS CHROMATOGRAPH. (Revised: )

PHYSICAL SEPARATION TECHNIQUES. Introduction

PAPER CHROMATOGRAPHY

Distillation of Alcohol

PRE-LAB FOR YEAST RESPIRATION AND FERMENTATION

EXPERIMENT 1 - Determination of the purity and identity of organic compounds by melting point and/or analytical thin layer chromatography

THERMAL DESORPTION. Introduction and Principles. Focusing on Volatiles

An Advanced Base Deactivated Capillary Column for analysis of Volatile amines Ammonia and Alcohols.

LIQUID CHROMATOGRAPHY HOW MUCH ASPIRIN, ACETAMINOPHEN, AND CAFFEINE ARE IN YOUR PAIN RELIEVER? USING HPLC TO QUANTITATE SUBSTANCES (Revised: )

Chemical versus Physical Changes

BTU ANALYSIS USING A GAS CHROMATOGRAPH

Melting Point, Boiling Point, and Index of Refraction

Project 5: Scoville Heat Value of Foods HPLC Analysis of Capsaicinoids

Warm-Up 9/9. 1. Define the term matter. 2. Name something in this room that is not matter.

RECITATION NOTES FOR EXPERIMENT # 5 A&B THIN LAYER CHROMATOGRAPHY

Chapter 21 Principles of Chromatography and Mass Spectrometry Problems 1,2,3,4,8,9,11,13

Diffusion and Fluid Flow

Bomb Calorimetry. Electrical leads. Stirrer

Chemistry 13: States of Matter

Shimadzu Simulated Distillation Gas Chromatograph System C184-E030

ATOMIC ABSORTION SPECTROSCOPY: rev. 4/2011 ANALYSIS OF COPPER IN FOOD AND VITAMINS

HEXANES. Insoluble in water, soluble in ether, alcohol, and acetone. Neutral to methyl orange (ph indicator) Not more than 0.

Distillation Experiment

In this experiment, we will use three properties to identify a liquid substance: solubility, density and boiling point..

Analyzing Small Molecules by EI and GC-MS. July 2014

The Empirical Formula of a Compound

Unit title: Chemical Laboratory Techniques

PURIFICATION TECHNIQUES

Chemical Analysis. Natural Gas Analyzer. A Family of optimized GC Solutions. Gas Chromatography. think forward

1 Introduction The Scientific Method (1 of 20) 1 Introduction Observations and Measurements Qualitative, Quantitative, Inferences (2 of 20)

GC METHODS FOR QUANTITATIVE DETERMINATION OF BENZENE IN GASOLINE

Isolation of Caffeine from Tea

The Theory of HPLC. Gradient HPLC

The photoionization detector (PID) utilizes ultraviolet

Quantitative Evaluation of Perfume Fleuressence Samples using the znose

Experiment 5: Column Chromatography

EXPERIMENT 1 (Organic Chemistry I)

Gas Chromatography Liner Selection Guide

Expectations for GC-MS Lab

Chapter 3: Water and Life

SUCRALOSE. White to off-white, practically odourless crystalline powder

Graphite Furnace AA, Page 1 DETERMINATION OF METALS IN FOOD SAMPLES BY GRAPHITE FURNACE ATOMIC ABSORPTION SPECTROSCOPY (VERSION 1.

CHEM 2423 Recrystallization of Benzoic Acid EXPERIMENT 4 - Purification - Recrystallization of Benzoic acid

CHAPTER 3: MATTER. Active Learning Questions: 1-6, 9, 13-14; End-of-Chapter Questions: 1-18, 20, 24-32, 38-42, 44, 49-52, 55-56, 61-64

Application Requirement

Intelligent use of Relative Response Factors in Gas Chromatography-Flame Ionisation Detection

Determination of Melting Points

THE HUMIDITY/MOISTURE HANDBOOK

Experiment 5 Preparation of Cyclohexene

SPE and HPLC. Dr Iva Chianella Lecturer in Analytical Chemistry Cranfield Health +44 (0)

Thermal Conductivity Detector

The Characterization of Perfume Fragrances Using GC/MS, Headspace Trap and Olfactory Port

ß-CYCLODEXTRIN SYNONYMS

Short introduction into. Analytical Chemistry. by Prof. Dr. Manfred Sietz and Dr. Andreas Sonnenberg (PowerPoint slides)

Overview. Triple quadrupole (MS/MS) systems provide in comparison to single quadrupole (MS) systems: Introduction

Training Courses 2014 HPLC GC SPE

Retention Parameters in Column Chromatography

CRYOCOOLER CONTAMINATION STUDY. S.W.K. Yuan, D.T.Kuo, and A.S. Loc. BEI Technologies, Cryocooler Group Sylmar, CA ABSTRACT

Gas Chromatography. Gas Chromatograph

IB Chemistry. DP Chemistry Review

MINERAL OIL (MEDIUM VISCOSITY)

Chapter 5 Classification of Organic Compounds by Solubility

Fundamentals of Gas Chromatography

Guide to Reverse Phase SpinColumns Chromatography for Sample Prep

Electrospray Ion Trap Mass Spectrometry. Introduction

Synthesis of Isopentyl Acetate

Chemical Equations & Stoichiometry

Compounds vs mixtures. Physics and Chemistry IES Jaume Salvador i Pedrol February 2009

Chapter Test A. Elements, Compounds, and Mixtures MULTIPLE CHOICE. chemically combined? MIXs2 a. element b. compound c. mixture d.

Making Biodiesel from Virgin Vegetable Oil: Teacher Manual

EXPERIMENT 9 (Organic Chemistry II) Pahlavan - Cherif Synthesis of Aspirin - Esterification

Gerhard Schomburg. Gas Chromatography. A Practical Course. -«WTM-JY// ^ Weinheim New York. VCH XJ Basel Cambridge

Spectrophotometry and the Beer-Lambert Law: An Important Analytical Technique in Chemistry

α-cyclodextrin SYNONYMS α-schardinger dextrin, α-dextrin, cyclohexaamylose, cyclomaltohexaose, α- cycloamylase

Physical and Chemical Properties of Matter

23 The Thermal Conductivity Detector

ORGANIC LABORATORY TECHNIQUES NEVER distill the distillation flask to dryness as there is a risk of explosion and fire.

Reaction of Magnesium with Hydrochloric Acid (Gas Laws) Chemicals Needed:

Separation of Dyes by Paper Chromatography

The Synthesis of trans-dichlorobis(ethylenediamine)cobalt(iii) Chloride

13C NMR Spectroscopy

EXPERIMENT 15: Ideal Gas Law: Molecular Weight of a Vapor

Process Instrumentation

Chapter 2. The Chemistry of Life Worksheets

Transcription:

CHEM 333L Organic Chemistry Laboratory Revision 1.2 Gas Chromatographic Analyses In this laboratory exercise we will analyze, using Gas-Liquid Chromatography (GC), the Fractions collected during our Fractional Distillation of the Cyclohexane-Toluene mixture and the Essential Oil obtained as a result of our Steam Distillation. The GC analysis of the Fractional Distillation fractions will allow us to determine the relative amounts of Cyclohexane and Toluene in each fraction collected. The GC analysis of the Essential Oil will allow us to determine the number of components present in the Oil, and to identify, via comparison with appropriate standards, the major component(s) of the Oil. Chromatographic separations are ubiquitous throughout chemistry and Gas Chromatography is a particularly important type of chromatography. Chromatographic systems trace their origins to an experiment conducted by the Russian scientist Mikhail Semenovich Tswett circa 1906 in which he reported separating the different colored pigments of plant leaves by passing an extract of the leaves through a column of calcium carbonate (think of powdered chalk); an early form of Column Chromatography. He coined the term chromatography, from the Greek words for "color" and "to write", to describe this method of separating chemical substances. Mikhail Tswett (http://www.wikidoc.org/index.php/ File:Tsvet_ms.jpg) Column Being Filled With Elutent (http://en.wikipedia.org/wiki/file:colortest.jpg) Presently, Chromatography is the general name applied to a series of separation methods that employ a system with two phases of matter; a mobile phase and a stationary phase.

P a g e 2 Analytes in a mixture to be separated interact with the stationary phase with different affinities. While moving through the system, carried along by the mobile phase, those analytes with a low affinity for the stationary phase will tend to move along rapidly, while those with a high affinity will tend to lag behind. Thus, the separation of analytes in chromatographic systems is based on the differential affinity of the analyte for the stationary vs. mobile phases. In Column Chromatography, the Stationary Phase is a solid support packed into a glass column. Liquid elutent, the Mobile Phase, is passed down the column, carrying the analytes with it. The separated analytes can be collected as they pass through the bottom of the column. If the analytes are colored, identifying when the analyte is about to pass off the column is simply a matter of watching its colored band migrate down the column. If not, then deciding when the analyte has passd off the column requires some form of detection system. Some of the more common types of Chromatographic systems encountered in the Organic Laboratory are: Paper Chromatography Thin Layer Chromatography Column Chromatography Gas-Liquid Chromatography Features of a Chromatographic Column (http://en.wikipedia.org/wiki/file:p1000495.jpg)

P a g e 3 We will employ the last three types of chromatographic separations during this laboratory course. Gas-Liquid Chromatography, the most common type of Gas Chromatography, employs a Gaseous mobile phase and a Liquid stationary phase. The mixture to be analyzed is injected into a heated Injection Port where it is vaporized. The resulting vapor then mixes with an inert Carrier Gas, which is typically Helium (He). This is the mobile phase. The carrier gas then flows through a heated column filled with support beads coated in an appropriate liquid; the stationary phase. The separation occurs while the mixture moves along the column. The separated species then pass out of the column and into an Exit Port where they pass through a detector. The detector then sends a signal indicating the presence of the analyte to an appropriate Read Out device, usually a computer. Components with a High Affinity for dissolving in the liquid stationary phase will tend to move slowly through the system; they are constantly being partitioned between the gaseous and liquid phases. Those components with a Low Affinity for the liquid support will tend not to be absorbed by the liquid and will move along fairly rapidly with the carrier gas. Thus, separation of the components in a mixture is dependent upon how well they partition and dissolve in the liquid stationary phase. This is a type of Partition Chromatography because the analyte dissolves in, and migrates into, the liquid stationary phase.

P a g e 4 This is important to understand because the partitioning of the analyte molecules between the gas and liquid phases leads to a differential lag time for each of the molecules of a given component as they pass through the system. As the band of molecules passes through the system, each molecule will spend a different amount of time within the liquid phase. This tends to broaden the band of molecules as it moves along. Other factors that tend to increase Band Broadening are the multiple pathways molecules may take through the system, diffusion in the mobile phase, etc.

P a g e 5 Band Broadening directly affects the Resolution of analyte bands as they exit the system. Two closely spaced bands will begin to separate and resolve themselves as they pass along the column. However, while passing through the system the bands begin to broaden, and this may cause a significant overlap of closely spaced bands, thereby reducing the Resolution of these analytes. The efficiency of Packed Columns increases considerably as the size of the solid particular support decreases. As an extreme, Open Tubular Columns, an open tube coated on the inside with the liquid phase, provide a high resolution alternative to packed columns. These columns are more expensive and more fragile to use than packed columns. However, because of much improved construction techniques, open tubular columns are now the most popular type of GC column in use. They can be constructed as capillaries as thin as 0.32 0.25 mm with lengths as long as a 100 meters. They are typically tightly coiled to fit within the confines of the GC oven.

P a g e 6 The trick in any chromatographic separation is to select a liquid stationary phase, an oven temperature, and a carrier gas flow rate so that all the analyte bands are fully resolved in a minimum amount of time. These selections are frequently empirically based, as much art as science, and are sometimes contradictory. In general, the polarity of the liquid used for the stationary phase should be consistent with that of the analyte. Separating polar compounds will require a polar column liquid and separating non-polar compounds requires a non-polar liquid. Common stationary phases for Gas Chromatography are listed below: Phase Polydimethyl Siloxane Applications Non-polar phase; hydrocarbons, drugs, steroids, PCBs. 5% Phenyl-polydimethyl Fatty acid methyl esters, alkaloids, drugs, halogentated Siloxane compounds. 50% Phenyl-polydimethyl Drugs, steroids, pesticides, glycols. Siloxane Polethylene glycol Free acids, alcohols, ethers, essential oils, glycols. 50% Cyanopropyl-polydimethyl Polyunsaturated fatty acids, free acids, alcohols. Siloxane If the column and analyte polarities are reasonably consistent, then the order in which the analytes come off the column will be according to their boiling points. Control of the GC oven s temperature is also critical for good resolution. As a rule of thumb, lower temperatures are better, however, this usually increases the time required for elution of the analytes. At a minimum, the temperature should be set just slightly higher than the boiling point of the analyte. A programmed temperature sequence may be required to separate many analyts. This starts with a fairly low temperature and then ramps up to elute the higher boiling components of the mixture. Although GC chromatography is most commonly used to provide a qualitative analysis of a mixture in question, quantitative information about the relative composition of the mixture can be obtained from the chromatogram. In generic GC systems, as the analyte passes into the exit port, it then passes through a detector that responds to the presence of the analyte. Most detectors in these systems are non-specific; they respond to the presence of the analyte but do not identify the analyte itself. The detector response is then sent to a readout device which produces a peak representative of the analyte concentration. We expect: Peak Area ~ Concentration of Analyte (Eq. 1) The relative concentrations of the different analytes in the mixture can be determined by comparing their different peak areas. And, most computerized readout systems are capable of integrating the analyte peaks to provide the needed peak areas. But, these non-specific detectors

P a g e 7 do not respond to all analytes equally; a given concentration of one analyte may produce a larger detector response than an equivalent concentration of another analyte. Therefore, we must determine each analyte's detector Response Factor, f i : A i ~ f i C i (Eq. 2) where A i is the peak area and C i is the concentration. Typically, this is done by performing an analysis on a Standard Solution where the concentrations of the analytes are known. The Relative Response Factor of component i to j (f i /f j ) is then determined: (C i / C j ) = (A i / f i ) / (A j / f j ) (Eq. 3) Once the Relative Response Factors are known, the relative concentrations of the analytes in the unknown mixture can be determined from their relative peak areas. For our analysis we will be using a basic Shimadzu GC-17A system: This includes ovens for the injection port, detector and column. The exit port is coupled to a Flame Ionization Detector (FID). The FID works by burning the eluted gas from the column in an H 2 and Air mixture. This produces CH species in proportion to the number of Carbon atoms in the flame. These CH fragments then react with Oxygen atoms in the flame and produce electrons: CH + O CHO + + e - (Eq. 4) These electrons then alter the current within the detector system. This current is then amplified and converted to a voltage for readout. The carrier gas for our system is Helium, the most common inert carrier gas used in these systems. Software controlling the Schimadzu GC is capable of programming the oven temperature for maximum resolution of the analytes in a mixture.

P a g e 8 We will first analyze the fractions from our Fractional Distillation of Cyclohexane and Toluene. This involves initially running samples of the individual components, Toluene and Cyclohexane, through the chromatographic system. This allows us to determine Adjusted Retention Time (t r ) for each component; the time it takes the component to migrate through the system, or Retention Time (t r ), versus the time it takes the mobile phase to do the same (t m ): t r = t r - t m (Eq. 5) Once the retention times are known, we will be able to identify the appropriate peaks in a chromatogram of a mixture. Then, we will run a 50:50 mixture of the hydrocarbons through the system. This will allow us to determine the Relative Response Factor of the detector for our components. Finally, we will run each fraction from the Fractional Distillation through the system, measure the appropriate peak areas and quantify how much of each component is present in the mixture. This will allow us to determine the efficiency of our Fractional Distillation for separating the Cyclohexane and Toluene. We will then turn to the analysis of the Essential Oil produced during our steam distillation procedure. We will be somewhat more qualitative in our approach here. Our desire is to simply identify how many components comprise the Oil and their likely identity by comparison with appropriately selected standards.

P a g e 9 Pre-Lab Questions 1. When 1.06 mmole of 1-Pentanol and 1.53 mmole of 1-Hexanol were separated by Gas Chromatography, they gave relative peak areas of 922 and 1570 units, respectively. When an unknown mixture of these two alcohols was likewise separated, the relative peak areas were 843:816 (Pentanol:Hexanol). What was the relative concentration of these species in the mixture? 2. Most GC columns are rated with an upper temperature. Why do you think this is?

P a g e 10 Procedure Your always helpful laboratory instructor will demonstrate the operation of the GC and how to inject a sample using the autosampler. Typical instrument parameters you should note are: Column Type Injection Port Temperature Column Temperature Detector Temperature Detector Type Carrier Gas and Flow Rate Collectively the class should run samples of: 1. Cyclohexane 2. Toluene 3. 50:50 mixture of Cyclohexane-Toluene 4. Essential Oil standards. (These will be selected by your instructor) Analyze these results for the retention times for each pure compound. Determine the relative detector response for Cyclohexane vs. Toluene; f tol /f cyclo. Individual samples should be run of: 1. Each fraction from the Fractional Distillation. 2. Essential Oil Determine C tol /C cyclo for each Fractional Distillation fraction. Determine the number of, and probable identity of, the components in the Essential Oil.

P a g e 11 Post Lab Questions The following questions will require a short search of sources such as Wikipedia or a good Instrumental Analysis book. 1. What is a Theoretical Plate, in the context of Gas Chromatography? How many theoretical plates is possible for a typical open tubular column? 2. What is Gas-Solid Chromatography and why is it less used than Gas-Liquid Chromatography? 3. What is a Thermal Conductivity Detector and how does it work? 4. If you injected a wet sample of an otherwise pure compound onto a gc column connected to a flame ionization detector, only a single peak would be recorded. Why? 5. Extremely narrow bore open tubular columns require a splitter at the injection port. What does the splitter do and why is it used?