To perform Ethernet setup and communication verification, first perform RS232 setup and communication verification:

Connecting the DG-102S VoIP Gateway to your network

ENET-710. ENET Ethernet Module ENET-710 JAN / 06 FOUNDATION

One Port Serial Server Users Manual Model ESP901, ESP901E

UDS1100 User Guide Part Number Revision B June 2006

BIT COMMANDER. Serial RS232 / RS485 to Ethernet Converter

UPS Network Interface. Quick InstallationGuide

VSCOM USB PRO Series Industrial I/O Adapters

TECH BULLETIN NETGEN1 DOOR CONTROLLER WI-FI NETWORK CONFIG

Secure Ethernet Gateway SEG-1 and SEG-M for IEI Access Systems Installation Manual

ACU-1000 Manual Addendum Replacement of CPM-2 with CPM-4

1.1 Connection Direct COM port connection. 1. Half duplex RS232 spy cable without handshaking

isco Connecting Routers Back to Back Through the AUX P

xpico User Guide Part Number Revision A April 2012

Prestige 314 Read Me First

Ethernet Radio Configuration Guide

Prestige 660R-6x Read Me First

Prestige 650R-31/33 Read Me First

Networking Alpha signs on a TCP/IP network

MS830 / MS833 Barcode Reader v1.0 9-December-2014

UDS-10, UDS100, UDS200 Quick Start Guide Copyright Lantronix is a trademark of Lantronix. All rights reserved Rev.

1. Hardware Installation

HWg-STE HWg-STE PoE MANUAL

OUTDOOR IR NETWORK CAMERA Series

T3 Mux M13 Multiplexer

How to setup the UCW232C Serial WiFi adapter

ReadMe File. Installing the Unified Messaging Application for

BASLER ACE QUICK INSTALLATION GUIDE

Prestige 324. Prestige 324. Intelligent Broadband Sharing Gateway. Version 3.60 January 2003 Quick Start Guide

SOHO 6 Wireless Installation Procedure Windows 95/98/ME with Internet Explorer 5.x & 6.0

50-Port 10/100/1000Mbps with 4 Shared SFP. Managed Gigabit Switch WGSW Quick Installation Guide

Easy Setup Guide for the Sony Network Camera

LS-101 LAN to Serial Device server. User s Manual

Using HyperTerminal with Agilent General Purpose Instruments

Setting up Digi Connect Wi-SP or Digi ConnectPort TS W Devices On a Secured Wireless Network for use with Veriteq viewlinc

S-SupremaConfigurationGuide-DOC 7/23/2014. Suprema Biometrics Configuration Guide ACS OnSite Aparato

Ethernet. Customer Provided Equipment Configuring the Ethernet port.

1 Serial RS232 to Ethernet Adapter Installation Guide

MODBUS TCP to RTU/ASCII Gateway. User s Manual

Technical Note. Setting ACS drive IP address automatically with Rockwell BOOTP/DHCP Server. Contents

DVR-4TL/8TL/16TL Setup Guide

Prestige 324 Quick Start Guide. Prestige 324. Intelligent Broadband Sharing Gateway. Version V3.61(JF.0) May 2004 Quick Start Guide

LBNP RS-232/485/422 serial device server. User manual

The GV-I/O Box 8 Ports provides 8 inputs and 8 relay outputs, and supports both DC and AC output voltages.

xdirect User Guide Part Number R Revision A September 2012

XPort Device Server User Guide

Operation Manual of EX-9132C-2. Serial to TCP/IP Converter

CS 326e F2002 Lab 1. Basic Network Setup & Ethereal Time: 2 hrs

How to setup a serial Bluetooth adapter Master Guide

WxGoos-1 Climate Monitor Installation Instructions Page 1. Connections. Setting an IP Address

IP SERIAL DEVICE SERVER

Crow Limited Warranty. Print Version 017

Configuring the Beckhoff BK9000 Network Parameters

About This Guide SolarEdge Configuration Tool Software Guide. About This Guide

PC Program User s Guide ( ) 1. Connecting the PC. 2. Installation and Start-up. 3. Programming

Maintaining the Content Server

Using a simple crossover RJ45 cable, you can directly connect your Dexter to any computer.

The GV-I/O Box 16 Ports provides 16 inputs and 16 relay outputs, and supports both DC and AC output voltages.

APPLICATION NOTE. CC5MPX Digital Camera and IPn3Gb Cellular Modem 10/14. App. Note Code: 3T-Z

Configuring a Trimble Sps 461 using the Ethernet Connection GETTING THE GPS ON THE NETWORK HTTP PORT. By Bob Glover

AutoWAVE. Programming Instructions P/N Part of Thermo Fisher Scientific. Revision D

Configuring the Switch with the CLI-Based Setup Program

16-Port RS232 to USB2.0 High Speed Multi Serial Adapter (w/ Metal Case) Installation Guide

SATO Network Interface Card Configuration Instructions

Follow these steps to prepare the module and evaluation board for testing.

Vantage RADIUS 50. Quick Start Guide Version 1.0 3/2005

Liebert IntelliSlot Web Cards

Configuring the WT-4 for ftp (Ad-hoc Mode)

Setup Manual and Programming Reference. RGA Ethernet Adapter. Stanford Research Systems. Revision 1.05 (11/2010)

Configuring the WT-4 for Upload to a Computer (Ad-hoc Mode)

Linksys Wireless G WRT54G

Programming and Using the Courier V.Everything Modem for Remote Operation of DDF6000

MODBUS TCP to RTU/ASCII Gateway

Prestige 202H Plus. Quick Start Guide. ISDN Internet Access Router. Version /2004

BiPAC 7404V series. VoIP/(802.11g) ADSL2+ (VPN) Firewall Router. Quick Start Guide

enervista UR Setup Software Quick Connect Instructions:

NPort s Ethernet Modem Mode

LAN / WAN Connection Of Instruments with Serial Interface By Using a Terminal Server

INSTALLATION AND OPERATION MANUAL CNFE2DOE TERMINAL SERVER

RJ45 Shielded (standard) port pinout. CS9000, Jetstream , Lanstream 2000, RTA8/RJX, RRC16, MTA8/RJX & SXDC8/RJX

SIP Proxy Server. Administrator Installation and Configuration Guide. V2.31b. 09SIPXM.SY2.31b.EN3

P Quick Start Guide. VoIP Analog Telephone Adaptor DEFAULT LOGIN. IP Address Password Version /2007 Edition 1

GV-Data Capture V3 Series User's Manual

UDS-10 External Network Interface Setup. User's Guide

TCP/IP Converter DDS EX-9132 Operation Manual for 8051 Series

Debugging Network Communications. 1 Check the Network Cabling

Configuring a customer owned router to function as a switch with Ultra TV

Industrial L2+ Managed Gigabit/ 10 Gigabit Ethernet Switch. IGS-5225 Series. Quick Installation Guide

Device Installer User Guide

Firewall VPN Router. Quick Installation Guide M73-APO09-380

TRP-C31M MODBUS TCP to RTU/ASCII Gateway

Transcription:

5 Gould Road, PO Box 2155 New London, NH 03257 Voice: (603) 526-9088 info@canarysystems.com www.canarysystems.com Overview Using the Lantronix UDS-1100 Device Server Application Note #20 The Lantronix UDS-1100 Device Server is device for interfacing serial port equipped hardware (either RS-232 or RS-485) onto Ethernet networks. These instructions will detail how to configure and use the UDS-1100 with various equipment including Campbell Scientific MCU s and Leica Total Stations. The UDS-1100 replaces the Lantronix UDS- 10. Wiring Various wiring conventions are shown in the table below. UDS-1100 DB25F Description In/Out Leica TPS RS-232 DB9M CR10X CSI I/O DB9M CR2xx CR800/CR1000 RS-232 DB9M RESmith RS-485 Adaptor 2 Transmit Data (TX) In 2 (White) 9 (White) 2 (White) 3 Receive Data (RX) Out 3 (Green) 4 (Green) 3 (Green) 4 Request to Send (RTS) In 5 Clear to Send (CTS) Out 6 Data Set Ready (DSR) Out 4 (Red) 3 (Red) 4 (Red) 7 Ground 5 (Black) 2 (Black) 5 (Black) COM 8 Data Carrier Detect (DCD) Out 9 3.3VDC Output Out 12 9-30VDC Input In 14 RS-485 TX+/RX+ Out RX+ 15 RS-485 TX-/RX- Out RX- 20 Data Terminal Ready (DTR) In 21 RS-485 RX+ In TX+ 22 RS-485 RX- In TX- Notes: 1. DTR handling on the UDS-1100 is set to Ignore by default. 2. For RS-232 operation jumper pins 4 & 5 together. 3. For 2-wire RS-485 operation wire pins 14 (TX+) and 21 (RX+) together and pins 15 (TX-) and 22 (RX-) together. Power must also be supplied to the UDS-1100 using the supplied AC adaptor or via the connections on the DB-25 connector. The UDS-1100 may require up to 125mA from the unregulated power input, with a nominal 12VDC supply typical quiescent current drain is 60mA, typical operating current is 85mA. Note: There is an optional terminal block adaptor available for use with the UDS-1100 that provides screw terminal connections when using RS-485. This is Lantronix part number 500-171-R. It provides separate terminal blocks for full/half-duplex RS-485 and the power input. Contact Canary Systems to order this adaptor. Using the Lantronix UDS-1100 Device Server Page 1 of 8

UDS-1100 Configuration Note: You will need to install the Lantronix DeviceInstaller software to configure the UDS-1100. Use the supplied CD. Steps as follows: 1. Connect power to the UDS-1100 using the supplied AC Adaptor. Using an RJ45 cable connect the Ethernet port on the UDS-1100 to the hub or switch being used by your computer. Make sure the green link light on the UDS-1100 is illuminated before proceeding 2. Run the DeviceInstaller software. You should see your network adaptor (Local Area Connection) shown in the navigator on the left. 3. Double-click on the Local Area Connection item to show the UDS connections. Using the Lantronix UDS-1100 Device Server Page 2 of 8

4. Double-click on the UDS connections to show the specific adaptors found. Note: If the adaptor does not show then check the power/rj45 connections, otherwise the adaptor may already be configured with an IP. By default the units are configured for DHCP which means they should be assigned an IP when connected to the network your computer is on. See the last section for instructions on configuring units with an unknown or unreachable IP. 5. Click on the tab Web Configuration, then External Browser. This will launch your default browser with the DHCP selected IP. Using the Lantronix UDS-1100 Device Server Page 3 of 8

6. The login dialog will display, just press <ENTER> or click the OK button to advance to the configuration screen, shown below. 7. Click on the Network option in the menu on the left to display the Network Settings form. Note the Use the following IP configuration group. Select this option and then configure the appropriate IP Address, Subnet Mask and Default Gateway to match the network to which the UDS-1100 will be connected. Using the Lantronix UDS-1100 Device Server Page 4 of 8

8. Click on the Channel 1 Serial Settings item and verify the settings shown below. These are the default settings. Configure the Protocol and Baud Rate according to the table shown below. Device Protocol Baud Rate Leica Total Station RS232 19200 CR2xx RS232 9600 CR800/CR1000 RS232 115200 CR800/CR1000 RS485 38400 9. Last step, click on the Apply Settings item shown in the menu on the left. Using the Lantronix UDS-1100 Device Server Page 5 of 8

Lost or Unknown IP Configuration This section will provide instructions for configuring the UDS-1100 IP address where the existing address is unknown or in a different subnet so communication from the host device is not possible using the Lantronix DeviceInstaller software. You will need the AC Adaptor and the DB25 to DB9 serial cable that are supplied with the unit. Connect the serial cable to the serial port on your computer. Start Hyperterminal (usually found in the Accessories Communications group), the first dialog will require you to configure a name for the connection. Use the baud rate in the Name for easier launch of Hyperterminal, as shown. Press OK to advance to the Connect To dialog, select the appropriate COM port from the list of available ports. The example uses COM1. Using the Lantronix UDS-1100 Device Server Page 6 of 8

Press OK to advance to the COM Properties dialog, Configure Bits per second of 9600, Data bits of 8, Parity = None, Stop bits = 1 and Flow control = None, as shown at right. Click OK to advance to the communications window. The port will be opened and available for communications after clicking OK. While holding the x key down (lower case), connect power to the UDS-1100. After a few seconds you should see the configuration screen as shown below. If the configuration screen doesn t show after 15 seconds then disconnect power and repeat the sequence. Using the Lantronix UDS-1100 Device Server Page 7 of 8

Press <ENTER> to go into Setup Mode. Note: You only have about 5 seconds to press <ENTER> otherwise the UDS-1100 will time out of configuration mode. After pressing <ENTER> the current settings followed by the Change Setup screen will display. You can use the scroll bar control on the right to back up the display and view the current configuration. Enter 0 <ENTER> for Server configuration. You will then be prompted to enter the 4 octets, one at a time, for the IP Address. This is followed by the Set Gateway IP Address, default is N but press Y to configure and then enter the 4 octets one at a time as needed. Configure Netmask if needed, then Change telnet config password if necessary. The Change Setup menu will re-display, optionally the serial port settings can be configured using option 1 <ENTER>, otherwise select 9 <ENTER> to save the settings and exit. You should be able to run DeviceInstaller now and connect to the UDS-1100. Using the Lantronix UDS-1100 Device Server Page 8 of 8